HomeMy WebLinkAbout268 Cedar Dr - 21106405015EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 Telephone: 328-8755 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1375 Please call for final inspection before covering any portion of installed system. OWNER: Michael Velasque2 PHONE: 524-9381 MAILING ADDRESS: P.O. BOX 2081 city: Gypsum Stale: GG Zip: 81628 APPLICANT: Michael VelasqueZ PHONE: 524-9381 SYSTEM LOCATION: Bertroch Lot 25 filing; 5 TAX PARCEL NUMBER: 2111-064-05-015 LICENSED INSTALLER: Bruce Bait LICENSENO: 34-94 DESIGN ENGINEER OF SYSTEM: INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: GALLON SEPTIC TANK ABSORPTION AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: ENVIRONMENTAL HEALTH APPROVAL: DATE: CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25- 10- 104. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET, INSTALLED SEPTIC TANK: GALLON DEGREES FEET FROM SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY YES —NO COMPLIANCE WITH COUNTY / STATE REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. COMMENTS: ENVIRONMENTAL HEALTH APPROVAL: DATE: ENVIRONMENTAL HEALTH APPROVAL: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS APPLICANT / AGENT: PERMIT FEE PERCOLATION TEST FEE RECEIPT # CHECK # incomplete Applications Will NOT Be Accepted (Site Plan MUST be attached) ISDS Permit # Building Permit APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE.- EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (Basalt) ************************************************************************** * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: / ► )1 c k A-c-_, ( V e /,¢ c •r ✓ me Z_ �r MAILING ADDRESS: -O , ;Z091C PHONE: APPLICANT/CONTACT PERSON: PHONE: LICENSED SYSTEMS CONTRACTOR: U c e_ 061, - PHONE: f2q/ COMPANY/DBA: ADDRESS: *************************************************************************** PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: �f `� 5 6e1z tR_Cc�,_ Tax Parcel Number: 06.f/-Lot Size: Physical Address: 16 8' C.e d is w- M z u. P BUILDING TYPE: (Check applicable category) (jGj Residential/Single Family ( ) Residential/Multi-Family* ( ) Commercial/Industrial* Number of Bedrooms Number of Bedrooms Type TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surface ( Public Name of Supplier: *These systems require design by a Registered Professional Engineer SIGNATURE: Date: ' ZG G AMOUNT PAID: S�� RECEIPT # : �a3s/ DATE: 6I CHECK #: /O CASHIER: _4/ COMMUNITY DEVELOPMENT DEPARTMENT (303) 328-8730 EAGLE COUNTY, COLORADO December 2, 1994 Michael Velasquez P.O. Box 2081 Gypsum, CO 81637 Dear Applicant, 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX: (303) 328-7185 The Environmental Health Division would like to notify you to make a formal request to extend your Individual Sewage Disposal System(ISDS) Permit #1375-94 into the 1995 construction year. The Environmental Health Division discontinued percolation tests on November 15, 1994 and final inspections on December 2, 1994 due to climatic conditions. ISDS permits are active for 120 days after the date of issue if no Building Permit has been issued for the same property. If a Building Permit has been issued for the same property the ISDS will expire at the same time as the building permit. If you still plan to apply for a Building Permit this year or in the early months of 1995 you will need to have a percolation test conducted before your Building Permit will be released. You will have to contact a Registered Professional Engineering(RPE) firm to conduct your percolation test. If you have had your permit issued and have not had your final inspection completed, but plan on constructing the system in the next few weeks, please give our office a call and we will evaluate your permit on a case by case situation. Please give the Environmental Health office a call at 328-8755, if you have any questions regarding your permit extension process. cc: ISDS Permit #1375-94 File COMMUNITY DEVLOPMENT DEPARTMENT (303)328-8730 EAGLE COUNTY, COLORADO 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX: (303) 328-7185 DATE•June 9, 1994 Michael Velazquez, Parcel # 211-064-05-015 Lot 25, Bertroch Filing 5 Dear I.S.D.S. Applicant: Your application for an Individual Sewage Disposal System (ISDS) Permit for #1375-94 has been received. Issuance of your permit is on hold until the following materials or fee(s) are submitted. Payment of $150.00 Application Fee Payment of $200.00 Percolation Test Fee Site Plan Licensed System Contractor (See attached list) X Engineer Design* Other: *The percolation test results indicate that the soil is not suitable for a conventional absorption system due to the percolation rate being faster than 5 MPI, (Section 4.05.03, Chapter IV, Eagle County Land Use Regulations), as well as the presence of shallow bedrock. Additional soil evaluation and design of a system by a registered Professional Engineer is required, in this case. If you have any questions please contact us at 328-8755. When calling or submitting information please reference your ISDS application #1375-94. Please submit information to: Eagle County Environmental Health Division P.O. Box 179 500 Broadway Eagle, CO 81631 ISDS PERMIT # I PERCOLATION TEST EAGLE COUNTY ENVIRONMENTAL HEALTH DEPT. OWNER:- fV) Lt Vf_A LEGAL DESCRIPTION: Lo- MAILING ADDRESS: _LO Zpg TYPE OF DWELLING:_S\V\%G_ Z)ve,j.K4�t)IJzv+NUMBER OF BEDROOMS TEST HOLES PRE-SOAKED: YES V/ NO TTME WaTry nrpmw rTat-Tivc mr rAT-T. T) n MV I f\A V 1) Ile%.rT 1 2 3 1 2 3 1 2 3 1 2 3 01 2,5 "AO 1110 f IA-1 3' ).qo 0 12 0 Cj 5 v e 16 12 6,5 0 71 1,00 AM j 1-2 IS 1, C' 142 toen S 4, zf, > _ci 5,0 I LA 3 3, \,rl� ZA D Time to drop last inch PERC RATE: MINIMUM LEACH FIELD SIZE: :tq MINIMUM SEPTIC TANK SIZE: PERC ST- DATE: EnTlrfibnmental Hea/lth----a-fficer rev.*6/90ks SOT 25 BERTROCH SUBDIVISION-FILING \005 TOWN OF GYPSUM, COUNTY OF EAGLE, STATE OF COLORADO 10.00' LJ.VV a Y Y INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 Telephone:328-8755 Town of G sum YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. Please call for final inspection before covering any portion of installed system. Yp PERMIT NO. 1677 OWNER: Roland Radler/ Menzel Incorporated PHONE: (970) 524-6510 MAILINGADDRESS: P.O. BOX 792 City: GVpSllm State: CO Zip: 81637 APPLICANT: Same PHONE: SYSTEMLOCATION: 268 Cedar Dr., Gypsum TAX PARCEL NUMBER: 2111-064-05-015 LICENSED INSTALLER: Bighorn Excavating, Ron (rout LICENSENO: 10-97 DESIGN ENGINEER OF SYSTEM: Tnter Mountain Engineering, Richard Ricks INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 1250 GALLON SEPTIC TANK ABSORPTION AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED4SQUARE ETOF TRENCH BOTTOM. Via 2-�r infilt ator Units as per design. SPECIAL REQUIREMENTS: Install as per engineer's design dated 2/6197, 'Engineer responsible for final inspection. ENVIRONMENTAL HEALTH APPROVAL: ' = Li DATE: March 20, 1997 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25- 10- 104. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: - J SQUA FEET. G\ _ LCWt/` 1 INSTALLED SEPTIC TANK: a 3 GALLON DEGREES FEET FROM SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND �I PROPER MATERIAL AND ASSEMBLY YES NO COMPLIANCE WITH COUNTY/STATE REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. � f COMMENTS: 0 " r o / oZ z cfD 11 fi I ENVIRONMENTAL HEALTH APPROVAL: DATE: `sue /,6 y ENVIRONMENTAL HEALTH APPROVAL: 4Z C DATE: (R -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS APPLICANT / AGENT: PERMIT PERCOLATION TEST FEE OWNER: RECEIPT # CHECK# (Site Plan MUST be attached) ISDS Permit APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) ************************************************************************** * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * * * MAKE ALI PROPERTY OWNER: MAILING ADDRESS: EASURER" ***************** �E : ( 7o APPLICANT/CONTACT PERSON: i C 1 I r G s' PHON U 77cj MAILING ADDRESS: �r LICENSED ISDS CONTRACTOR: COMPANY/DBA: PHONE: ADDRESS: 7Ne*w PERMIT APPLICATION IS FOR: ( Installation ( ) Alteration ( ) Repair LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Building Permit # (if known) Legal Description: Subdivision: S"-6-ocy iling: Block: Lot No. Tax Parcel Number: _ % % -_ -_- _ Lot Size: Street Address: 2 C-C'�C�� BUILDING TYPE: (Check applicable category) (Residential/Single Family Number of Bedrooms ( ) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type TYPE OF WATER SUPPLY: ( ) Well ( ) (Public _Name (Check applicable category) Spring ( } Surface of S,upplier: *These system ',d d6si n by a Registered Professional Engineer SIGNATURE • t Date: TO BE COMPLETE� BY THE COUNTY ' > AMOUNT PAID: t.�a. RECEIPT # : 1 `i () DATE: CHECK #: I & CASHIER: tc / A Fi Community Development Deparment 9701 328-8730 Fax: (970) 328-7 185 -DD: i970i 328-8797 Date: March 20, 1997 TO: Bighorn Excavating FROM: Environmental Health Division Eagle County Building P.O. Box 179 500 Broadway Eagle. Colorado 31631-0179 RE: Issuance of Individual Sewage Disposal System Permit No. 1677-97. Tax Parcel # 2111-064-05-015. Property Location: 268 Cedar Drive, Gypsum, CO, Radler residence. Enclosed is your ISDS Permit No. 1677-97. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files Inter -Mountain Engineering, Richard Ricks Community Development Department (970) 328-8730 ax: 970; 328-7185 TDD: '970) 328-8797 EAGLE COUNTY, COLORADO May 19, 1997 Roland Radler P.O. Box 792 Gypsum, CO 81637 RE: Final of ISDS Permit No. 1677-97, Tax Parcel #2111-064-05-015. Property location:268 Cedar Dr., Gypsum, CO. Dear Mr. Radler: Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL:Information Brochure Final ISDS Permit cc: files I k111) PAGE 01 Post-W Fax Note ':- 7671 " ='77! 74 May 15,1997 Rolland Radler Post Office Box 792 Gypsum, Colorado 81637 Septic System ErispWfon Lot 25, Bertroch Ranqh Project No. 96-042SE M-M The undemigned visited the jtt6joo sjtee� .. inspect tflo iWWW10n of the septic systerri_ The septic tystem was installed in gene r4 OMPIW=' Mith the PrelirSeptic$,ystem Llt�sign for Lot 25, Bertroch Ranch, Eagle County,.t6fort4'0. Chatiges to tb&'installed system consisted of the location and configuration of ;:1ha�$Vjjo::Unk (moved slightl$.'toward the northeast from the point shown on the glans to avoid t ifii "WItY.) and the placer vi"tof ffie infiltrator bid.�). Also, of site access difficulties and. "*rfh4"-onditi0rt%,' shallb* bedrock, two of the initial infiltrators was not installed. Twenty fi2t ttat4i were installed. n.o infiltrators were installed as five rows containing four and one:mw' conWhing five for atot�,t.bftzkV(* _nty It is our opinion that the woOr orrus'­_ � '.tW- , � o Jinfiltraturs brorn *e system will not fin -Lit the effectiveness of the system. It generally per iLj,Aj, , 06 6W'ihe percolations raWs range from. 8 to 21 rn,inutes with occasional areas where 1,4�.Pemt" soils are encotiawred. The system was designed based UPOD ii i7,crzofiation rate, of 20 146utes Oct inch so the dosigited system may be slightly conservative.] Al so, because of site access 0 a: 0051* A profile We was dug at fidO was not perforn*1 initially, the time of the excavation at-it'AdwagrAdient point see AMWhed sketch. The soils in the profile bole were described as a sandy 41LT to a depth of 9 fee, An asbuilt sketch is recommend for the owners convenience, Inter -Mountain Engin e-1-M139, L�0­4 ph� ed to hoes works --� ith you on this project. Should you have any questions regarditS.*iirfCsrltitation contai.ned in Ws report, please contact the undersigned. ZResp fly, R Richard 06 Rick , P.E. Gwtcihnical Engineering Oso0s'Jetters\9604250 77 Metcalf Road, 0201 a Box 978 9 Avon, Colt)f8do 81620 * Phohe: 970-949-5072 o From Denver Direct: 893-1531 1420 Vance Street, # Lakewood, Colorado 80215 a Phone: 303-232_0158 t4. riu 17tC1t3 TC:D PAGE 02 Z.D L 0 T 14 ma`s t�r?�r��¢►' PROJECT HR,> �* p�tuw �v SCCL+ A4YE� FIGURE N4.1 K ter-Mountain Engineering Ltd. February 24, 1997 Eagle County Environmental Health Attn: Heather Savalox PO Box 179 Eagle, CO 91631 RE: Preliminary Septic System Design Lot 25, Bertroch Ranch Project No. 96-0425E Dear Heather: I am enclosing the results of all our percolation testing performed at Lot 25, Bertroch Ranch. We initially performed 5 percolation tests (Set A) along the east of the house. Because of rolling topographic restraints and poor backhoe accessibility we performed 3 more percolation tests (Set B) in and area which appears to be more suitable for an absorption field, refer to attached site plan. The last one of these we feel is to be voided, probably due to possible smearing of the hole. The percolation test, test 3 of set B, do not appear to be consistent with remaining tests. Enclosed is an 8 X 11 copy of the preliminary septic system design and copies of the measurements for Set A and Set B. Please contact the undersigned if you have any questions regarding this design. Thank you, kl- &1-�l JG V. Gabriel, P.E. Staff En er Richard O. Ricks, P.E. Geotechnical Engineer enc.: 3 pages 77 Metcalf Road, #201 • Box 978 • Avon, Colorado 81620 • Phone: 970-949-5072 • From Denver Direct: 893-1531 1420 Vance Street • Lakewood, Colorado 80215 • Phone: 303-232-0158 Percolation Test Data SET A Inter-Mouataia AYAJn Enginee ingua. Project # 96-0425E Location: Lot 25 Bertroch Subdivision 285 Cedar Drive Test Hole #: #1 Time Interval Measurement Drop in H2O Perk -Rate [Min) [Feet] [Inches] [Inches] [Min/in) 0 1 10 7/16 Water Added 15 1 11 318 - 15/16 •16.00 15 2 1/4 - 718 -17.44 0 1 9 7116 Water Added 15 1 10 7/8 •1 7116 •10.43 15 2 0 -1 1/8 -13.33 0 1 9 1/2 Water Added 15 1 10 718 -1 318 -10.91 Design Perc. Rate for Hole #1 - 12 [MiMnch] #2 Time Interval Measurement Drop in H2O Perk -Rate [Min] [Feet] [Inches] (Inches) [Minlin] 0 1 6 118 Water Added 15 1 7 7116 -1 5/16 -11.43 15 1 8 1/2 -1 1116 •14.12 0 1 7 3/8 Water Added 15 1 8 112 -1 1/8 -13.33 15 1 9 1/2 -1 •15.00 0 1 7 518 Water Added 15 1 8 13116 -1 3/16 .12.63 Design Perc. Rate for Hole #2 - 14 [MiMnch] #3 Time Interval Measurement Drop in H2O Perk -Rate [Min] (Feet) [Inches] [Inches] [Min/in] 0 1 3 9/16 Water Added 15 11 4 7/16 -34.29 15 1 4 3/8 - 318 40.00 15 1 411/16 - 5116 48.00 0 1 3 112 Water Added 15 1 3 13/16 - 5116 48.00 15 1 4 3116 - 3/8 40.00 #4 #5 Design Perc. Rate for Hole #3 - 48 [MiMnch] Time Interval Measurement Drop in H2O Perk -Rate [Min] [Feet) [Inches] [Inches] [Minrin] 0 1 5 314 Water Added 15 1 6 1/2 - 3/4 -20.00 15 1 7 3/16 .11116 -21.82 0 1 6 1/16 Water Added 15 1 6 13/16 - 314 -20.00 15 1 7 1/2 - 11/16 -21.82 0 1 6 Water Added 15 1 6 314 - 314 -20.00 Design Perc. Rate for Hole 94 - 21 [MiM-111 Time Interval Measurement Drop in H2O Perk -Rate [Min) [Feet) [Inches] [Inches] [MinAn] 0 1 8 Water Added 15 1 9 9/16 -1 9/18 -9.60 0 1 8 5/16 Water Added 15 1 9 7/8 •1 9116 -9.60 15 1 10 5/8 - 3/4 .20.00 0 1 8 5/16 Water Added 15 1 9 7/8 -1 9116 -9.60 Design Perc. Rate for Hole #5 - 10 [Min/Inch] NOTE: FOR LOCATIONS REFER TO SITE PLAN. 12PUIEP&MAI 9 Percolation Test Data Project # 96-0425G Location: Lot 25 Bertroch Subdivision Test Hole #: #1 #2 w0w3 n - Mountain ixgineeringut. Time Interval Measurement Drop in H2O Perk -Rate [Min] [Feet] [Inches] [Inches] [Minrn] 0 1 9 1/16 Water Added 15 1 11 1/8 -2 1/16 -7.27 0 1 8 7/16 Water Added 15 1 10 7/16 -2 -7.50 0 1 7 118 Water Added 15 1 9 1/8 -2 -7.50 0 1 7 1/16 Water Added 15 1 8 7/8 -113/16 -8.28 0 1 7 1/4 Water Added 15 1 8 7/8 -1 5/8 -9.23 0 1 7 118 Water Added 15 1 8 3/4 -1 5/8 -9.23 Design Average Percolation Rate: Design Perc. Rate for Hole #1 - 1.0 [Min/Inch] Time Interval Measurement Drop in H2O Perk -Rate [Min] [Feet] [Inches] [Inches] [Minfin] 0 1 10 3/8 Water Added 15 2 1 -2 518 5.71 0 1 713/16 Water Added 15 1 10 7/16 -2 5/8 4.71 0 1 6 718 Water Added 15 1 9 1/2 -2 5/8 5.71 15 1 11 3/16 -111116 -8.89 0 1 9 1/4 Water Added 15 1 11 1116 -113/16 -8.28 0 1 9 1/8 Water Added 15 1 1015/16 -113/16 -8.28 Design Average Percolation Rate: Design Perc. Rate for Hole #1 - 10 [Min/inch] Time Interval Measurement Drop in H2O Perk -Rate [Min] [Feet] [Inches] [Inches] [Min/in] 0 1 3 1116 Water Added 15 1 313/16 3/4 -20.00 15 1 4 1/8 - 5/16 48.00 15 1 4 5116 3/16 -80.00 15 1 4 7/16 1/8 -120.00 45 1 4 7/8 7/16 -102.86 Design Average Percolation Rate: Design Perc. Rate for Hole #1 - 10 0 [Min/Inch] NOTE: FOR LOCATIONS REFER TO SITE PLAN. NOTE: AN VALUE OF 20 min/inch NOTE: TEST #3 DID NOT APPEAR TO BE REPRESENTATIVE. POSSIBLE SMEARING OF PERCOLATION HOLE. PERC425B.XLS WNUM am; �.e... �r ■. wt rrsns ss wr�r Nita. r aw►rr��r: �,�rr�:,�r� �w are � r mr �r � � r � wr �