Loading...
HomeMy WebLinkAbout7747 County Road 100 - 239109100008 - OWTS-10-11-6712Work Classification: ReplacePermit 007747 cr 100 CARBONDALE CO 81623- Address Owner Information Permit Status: Active Project Address 239109100008 Permit Type: OWTS Permit Permit NO. OWTS-10-11-6712 Expires: 3/16/2012 Issue Date: 11/17/2011 Parcel No. 007747 CR 100 CARBONDALE, CO 81623- Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) Contractor(s)Phone Primary ContractorLicense Number ZEN EXCAVATION (970)274-0740 Yes QUARTER CIRCLE 8 LLP Permitted Construction / Details: This system is to serve a maximum of a 3 bedroom single family home. Installation is granted for a two compartment, 1000 gallon tank, with a cleanout between the dwelling and the tank. Water line/building sewer line crossing is only allowed if the water or wastewater conveyance pipe is encased for a minimum distance of ten feet on each side of the crossing. The existing tank (concrete mixer) must be pumped and either removed (and properly disposed of) or filled with dirt. The sewage effluent line which is to be under any areas that may be driven over must be of schedule 40 or stronger walled pipe unless the pipe is sleeved with schedule 40 or stronger walled pipe. Blue board could aid in freezing protection. The leach field shall consist of 45 ADS Arc 36 units placed in serial distribution and trench configuration, to provide 1136 square feet of absorption area credit. Remove any cobbles from the trench bottoms. Install at least one inspection portal in each trench. Do not backfill with any cobbles greater than 8 inches in diameter. Screen soil if necessary. Rack trench bottoms and sidewalls if there is any smearing of the soil. Maintain all required setbacks. Do not install in wet or frozen soil conditions. Call Eagle County Environmental Health (970-328-8755) for a final inspection before burying any of the system components. Issued by: Environmental Health Department, Eagle County, CO November 17, 2011 Date Customer Copy Terri Vroman CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED Work Classification: ReplacePermit 007747 cr 100 CARBONDALE CO 81623- Address Owner Information Permit Status: Active Project Address 239109100008 Permit Type: OWTS Permit Permit NO. OWTS-10-11-6712 Expires: 3/16/2012 Issue Date: 11/17/2011 Parcel No. 007747 CR 100 CARBONDALE, CO 81623- Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) Contractor(s)Phone Primary ContractorLicense Number ZEN EXCAVATION (970)274-0740 Yes QUARTER CIRCLE 8 LLP Permitted Construction / Details: This system is to serve a maximum of a 3 bedroom single family home. Installation is granted for a two compartment, 1000 gallon tank, with a cleanout between the dwelling and the tank. Water line/building sewer line crossing is only allowed if the water or wastewater conveyance pipe is encased for a minimum distance of ten feet on each side of the crossing. The existing tank (concrete mixer) must be pumped and either removed (and properly disposed of) or filled with dirt. The sewage effluent line which is to be under any areas that may be driven over must be of schedule 40 or stronger walled pipe unless the pipe is sleeved with schedule 40 or stronger walled pipe. Blue board could aid in freezing protection. The leach field shall consist of 45 ADS Arc 36 units placed in serial distribution and trench configuration, to provide 1136 square feet of absorption area credit. Remove any cobbles from the trench bottoms. Install at least one inspection portal in each trench. Do not backfill with any cobbles greater than 8 inches in diameter. Screen soil if necessary. Rack trench bottoms and sidewalls if there is any smearing of the soil. Maintain all required setbacks. Do not install in wet or frozen soil conditions. Call Eagle County Environmental Health (970-328-8755) for a final inspection before burying any of the system components. Office Copy November 17, 2011 Issued by: Environmental Health Department, Eagle County, CO Date Terri Vroman CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED 1z i, 30 DEPARTMENT OF ENVIRONMENTAL HEALTH (970)328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eaolecountv.us EAGLE COUNTY P.O. Box 179 500 Broadway Eagle, CO 81631 www.eagleoounty.us PERMIT APPLICATION FOR ONSITE WASTEWATER TREATMENT SYSTEM OWTS PERMIT # I Q — I (— 1 lZ BUIL.DING PERMIT # INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED) - - FEE SCHEDULE APPLICATION FEE $800.00(MAJOR REPAIR FEE 00.00 INOR REPAIR FEE $400.00 This fee includes the OWTS Perrm a ua t n ercolation Test, or Soil Profile Observation) and Final Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction site visit or consultation is needed. The re -inspection fee is $135.00 Make all remittance payable to: Eagle County Treasurer. Property Owner: oU ay-fe ►- V i r cI t? g LL P Phone: v Mailing Address: rl 7 `71 7 G k' )OC� ['ti r b 0Yi d email (' O I (a 2 3 Registered Professional Engineer: Phone: � r [ �A r, Applicant or Contact Person: "` �,Y�t,� I e l 55+' �rPhone:� -7O_ 1-7 " n Licensed Systems Contr� cctor: -e l Fx- c (- uaAr' Nicene # !75 i IT h j / Company DBA: C IJGc } r C1 +'� Phone: — —_- ( J 7`�` b Mailing Address: T '74V Rkk7WOOd 0 (� b mail �2✓1 e }l C'G( Vd �i a h ®� UQ , C 0 h Permit Application is for: New Installation Alteration Repair Yv� lit J 0 ✓ Location of Proposed Onsite Wastewater Treatment System: Ly�1(0 Legal Description: Se c,F r an ' `1' Toc.ur)sik v . 7 &a_v1G e -, 9 7 f C L i A ax Parcel Number: / ` 06 - 0 4 Lot Size: 3,� . 41& q L YAP S Assessor's Link: www.eaPJecount_y.us/Vatie/ pojajIlePhysicalAddress: 77 � � % d 01 r4 4 Y be" " (f 0 9 f b 2,3 Building Type: Residential I Single Family Number of Bedrooms:&�& Residential /Multi Family Num of edrooms: -P" 4&44z�t Commercial / Industrial* Type of Use: *These systems require design my a Registered Professional Engineer Type of Water Supply: Private Well Spring If Public Name of Supplier: Applicant Signature: Surface Public alj�l Office Use Only `J Amount Paid: Receipt #: Check #: T (o ff Date: t d S' ( l ISDS PERMIT # l0 - t 1 - (oI BUILDING PERMIT # [V/A _ SOILS EVALUATION/PERCOLATION TEST EAGLE COUNTY' ENVIRONMENTAL HEALTH OWNER: S c.. L P PHSYSICAL ADDRESS: J77447 SUBDIVISION: LOT NO.: TYPE OF STRUCTURE: 5 F NUMBER OF BEDROOMS: 3 TEST HOLES PRE-SOAKED: YES NO SOIL Z'EVIE WATER DEPTH INCHES OF FALL RATE PROFILE 4' it 3f� i,�5 _.\ 3,3 Z,4� a.5 �l 29 l�P.s� '4 �� 7 i•0��5 I,1�7� a,�5 `{.,`7I `�. 2-1 J a.1 3' P ,��l� /, 37S ,� 5.� 3 4, 1'6, 79 ko ?,3 f � 33 �' (� ! (� 5, 8' 3.25 3/j2h ,�s ao .ate RE 9' (ri.t5 '��5 ,�51� , 3,3 as 10, TIME TO DROP LAST INCH: PERC RATE: MINIMUM LEACH FIELD SIZE: MINIMUM SEPTI ' R 3lyl(A "I .�"zh . 3 r" 1�> COMMENTS: U 1?� Z S 3 7 -)-C a 5 G� �rFs WATER SUPPLY: ❑ PUBLIC E3/PRIVATE _ WELL LOCATION: —z �L OTHER WATER FEATURES: ' ENVIRONMENTAL HEALTH SPECIALIST DATE Mr. Dick Bachelder 12, ` ADS Model Leaching Chambers (Model ARC 36 LP) — RCVIS10E15 to Allowable Field Size Reductions (Area -Equivalents) a�jp rage 2 2�.2�i Requested Allowable Area -Equivalents Arc Arc 36 LP (by Application) Chamber Chamber (as initial (as modified _ a rovedproduction) `Drench — per chamber (sq ft/chamber) — 24.5 QLD includes 50% reduction to bottom area Trench — per linear foot (sq ft/lin ft) — 4.9 4.9 includes 50% reduction to bottom area Bed -- per chamber (sq ft/chatnber) — 20.42 20.33 includes 40% reduction to bottom area Bed — per linear foot (sq ft/lin ft) — — 4.08 4.07 includes 40% reduction to bottom area Bottom area of chamber for bed application 12.26 µ� _ 12.26 with no reduction (sqft/chamber) If you have any questions, please contact meat (303) 692-2 366 or barbai-a.dallemand("r]state.co.us at your convenience. Sincerely. Barbara L. Dallemand, P.E. Onsite Wastewater Program Coordinator Water Quality Control Division cc: Local llealth Agencies (O2 0 �o�a 3' s us- �AJU7/v� 45��� u5 v � 75C7 ��v uYL�fs yy ,55 a� u5 AY-c u _ Mr. Dick Bachelder ADS Model Leaching Chambers (Models Arc 48, Arc 24, Arc 36 and Arc 36HQ Approval 1'or Use in Colorado and Allowable Field Size Reductions (Area-C quivalents) Requested Allowable Area -Equivalents (by Are 18 Are 24 Are 36 Are 36 HC Application) 'french per chamber (sq fi/chamber) 12.53 17.2 25.25 28.45 includes 50% reduction to bottom area 'french - per linear foot (sq fiJin ft) 2.51 3.44 _ 5.05 5.69 includes 50",b reduction to bottom area Bed per chamber (sq tt/chamber) - 933 13.25 20.25 20.42 includes 40% reduction to bottom area [fed per linear foot (sq ft/lin ft)— 1.87 2.65 - - _ 4.05 4.08 includes 40"o reduction to bottom urea Bottom urea ofchantber for bed application with no 5.6 _ 7.95 12.15 12.25 reduction (sq fUchamber)� If'vou have any questions, please contact me at (303) 692-2366 or barbara.dallemand((r,:;late.co.tts at yuttr convenience. Sincerely. Barbara I.. Dallemand, P.L. Onsite Wastewater Pro -ram Coordinator Water Quality Control Division Cc: Local I lealth Agencies Mike Sims, ADS, Inc. Mike Knipp. ADS, Inc. STATE OF COLOIJ,tADO Bill Hitter, Jr., Governor Martha E. Rudolph, Executive Director Dedicated to protecting and improving the health and environment of the people of Colorado 4300 Cherry Creek Dr. S. Denver Colorado 80246-1530 Phone (303) 692.2000 TDD I ine (303) 691- 700 Located in Glendale, Colorado http://www.cdphe.state.co.us April 14.2010 Mr. Dick Bachelder On -Site Consultant ADS. Inc. 71 Orchard farm Rd. York, Ml 03909 Laboratory Services Division 8100 Lowry Blvd. Denver, Colorado 80230.6928 (303) 692-3090 Of C re -}4 Colorado Department of Public Health and Environment Re: ADS Model Leaching Chambers (Models Arc 18, Are 24, Arc 36 and Arc 3611 ) Approval for Use in Colorado and Allowable Field Size Reductions (Area -Equivalents) Dear Mr. Bachelder: In response to your letter and memorandum of March 4, 2010, the Colorado Department of Public I lealth and Environment - Water Quality Control Division (WQCD) has reviewed you- request for area -equivalent values for ADS chambers to be used for reductions in absorption field areas in Colorado. Area -equivalents are the horizontal area per chamber unit or area per linear foot that can be used to calculate the number of chamber units needed for an absorption field area as calculated in accordance with Section VIII.C.1.d. of the "Coloruclo State Board of Health Guideline.; on Individual Sewage age Disposal Systems " J C(T 1003-6 (Guidelines). Per Guidelines Section VII1.C. Le.(' - "Reduction in soil absorption area may be allowed for gravelless soil absorption systems upon approval of the Department and at the discretic n of the local health officer or his/her designated agent." Since 1991, the WQCD has allowed up to 50% reduction in absorption field size in trench applications and up to 40% reduction in bed applications from the absorption field sires determined using the techniques in the Guidelines. A methodology for determining areas for bottom and side walls to be used with reductions was accepted by the WQCD in 1996 WQ('D calculated the allowable area -equivalents for the four ADS models proposed ir.. your letter using the 1996-approved methodology and determined that the area request by ADS, [tic. are consistent with those values. Accordingly the WQCD approves the following allowable area - equivalents for use in Colorado. Note that local health agencies may elect to require more stringent values. STATE OF COLORADO John W. Hickenlooper, Govemor Christopher E. Urbina, MD, MPH Executive Director and Chief Medical Officer Dedicated to protecting and improving the health and environment of the people of Colorado 4300 Cherry Creek Dr. S. Denver, Colorado 80246-1530 Phone (303) 692-2000 Located in Glendale, Colorado http://www.Cdphe.State.co.us May 5, 2011 Mr. Dick Bachelder On -Site Consultant ADS, Inc. 71 Orchard farm Rd. York, ME 03909 Laboratory Services Division 8100 Lowry Blvd. Denver, Colorado 80230-6928 (303) 692-3090 Re: ADS Model Leaching Chambers (Model ARC 36 LP) — Revisions to Allowable Field Size Reductions (Area -Equivalents) Dear Mr. Bachelder: Yl 1876 } Colorado Department of Public Health and Environment In an April 6, 2011 letter, ADS, Inc. provided the Water Quality Control Division (Division) revised dimensions for the ADS Model ARC 36 LP chambers which differ slightly from the dimensions of the early manufactured chambers approved December 8, 2010. On the basis of the "'Colorado Srate Board of fieallh Guidelines on Individual Sewage Disposal Syslems" S CCR 1003-6 (Guidelines) Section V III.C. Le.(3), the Division has reviewed the revised dimensions and resulting area -equivalent values. The differences are small. However, the Division is issuing this revised approval letter to be consistent with the new actual production values. Guidelines Section VIII.C.I .e.(3) provides that "Reduction in soil absorption area may be allowed for gravelless soil absorption systems upon approval of the Department and at the discretion of the local health officer or his/her designated agent." Since 1991, the Division has allowed up to 50% reduction in absorption field size in trench applications and up to 40% reduction in bed applications from the absorption field sizes determined using the techniques in the Guidelines. A methodology for determining areas for bottom and side walls to be used with reductions was accepted by the Division in 1996. Area -equivalents are the horizontal area per chamber unit or area per linear foot that can be used to calculate the number of chamber units needed for an absorption field area as calculated in accordance with the Guidelines Section VIII.C.I.d. The Division verified the allowable area -equivalents for Model ARC 36 LP chambers using the 1996- approved methodology and determined the areas based on the revised values. Accordingly the Division approves the following allowable area -equivalents for use in Colorado. Please note that local health agencies may elect to require more stringent values. Map Page 1 of 1 Guarlev, C,-cb- S LLLP Map Parcels Parcels with Owner info (01/21/11) Parcels 0 County Boundary a Highways http://gisweb/aspnet_client/ESRI/WebADF/PrintTaskLayoutTemplates/default.htm 10/5/2011 .. IN;f Zh �•c. - IV f -..w .. Perc test hole> 1" Y f� iY„� /' � �.' �lsl,"Fi ?y-0r '�-+'�i'�r`1t'�'• � �+r,% y-n�v i t rr i 1 � •A .1 � 4 ! 1. J. (' - Ar '�.. i4V .F.' - �i �i a' a•i Id' .. 9`I I w •fyu;i - f �.. _ ... '.� r.�2i�1 Svc �['�•.. , r 7747 Cty Ro4,'l iYd; ' Carbo Quarter Circle- LLP 2391 -091 -OM08 LF 201110.17 4 M _- � s / t t ' WNW 7747 Cty Road 100, Carbo, dal;` Quarter Circle 8 LLP 2391 -091 -OM08 LF 2011 A 0017 1 v. y\ ►.,.. rw.. -�a..k T'i arYf,/^. v -Td�"� c't NY f A .,�fio,.��_r. � t. V _ - > _ "ram +�,,,. _'`,� �- -.. � � ,�.:' •. „�c�:T��-w ,\l _. � s, w r: a - �` "I - of frI ..,. :- +-R,._� 1.7 t. TO 1`\.::40 _, -�[�"r.1.,' k i I eff..� _.A > All I w ✓ `�t -T' �! ZI ok lop so t 9 ter i "Ire I IA I ' LL 17 ram. �4Sf{�1 '.s�� 'L �r.4C:f3�A'� 1.,�.i a.. 'LY i . Wlti .� �_•L� - F� Quarter Circl 8, LLP 7747 CR 1 , Carbondale 2011.11.29E LF � 7v .4 =r - •�� q,. Kra.,.. �! Well Head r '�i �F' t + nerot m - i«�'w - ,/,itn • l S , t 'c': <+•�:i�,=ice , Yl� + �F �w J 1. _ dP 9 x .tom odes osure' or cleanout - Quarter Circle 8 LLP .4111,11 7747 CR 100, Carbondale 2011.11.29 LF Quarter Circle 8, 7747 C R 1007 C; 011 11 29 LF LLP d _, �ti� i 1 � � . -- tram - S �i Zo IIIIIti . l CiTiZi z jj arfe ircle 8, LLP 747 C 00, Carbondale 2,011.11 F a•yy-$. { ,. ` IL t,. 1000 gallon tan r 44 . r•nY 4 Quarter Circle 8, LLP 7747 CR 100 Carbondale 2011011029 LF encne i I[_