Loading...
HomeMy WebLinkAbout1204 Daggett Ln - 211119100003Work Classification: NewPermit 899 DAGGET LANE GYPSUM CO 81637- Address Owner Information Permit Status: Active Project Address 211119100003 Permit Type: OWTS Permit Permit NO. OWTS-8-13-9546 Expires: 1/2/2014 Issue Date: 9/4/2013 Parcel No. 1204 DAGGETT LN Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: (970)471-1021 Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)471-2121BROCK CONSULTING, LLC Contractor(s)Phone Primary ContractorLicense Number BROCK CONSULTING LLC (970)328-2123 Yes29-13 LAURA AND STEVEN HAGEN Permitted Construction / Details: This Brock Consulting, LLC engineer design resubmittal dated September 4, 2013 has a tank sized for up to 5 bedrooms, but the leach field is only sized for 3 bedrooms. Install per design a 1500 gallon, two compartment concrete septic tank with a cleanout between the dwelling and the tank. Use schedule 40 PVC and insulate under the driveway and any parking areas with 2” rigid insulation. The absorption field is to consist of 28 Quick 4 Infiltrator units in two trenches to provide 560 sq ft of absorption area credit or an actual area of 280 sq ft. Trench should follow the natural surface contours and be level. Rake trench bottom and sidewalls to eliminate smearing and remove any cobbles in trench bottoms and in backfill material. Provide inspection portals at each end of the trench. Maintain all required setbacks. Do not install in wet or frozen soil conditions. Call the design engineer for a final inspection before burying any of the system components. In order to receive final approval, the engineer must provide the final certification letter, photos of the installation, and as-built drawings of the system. Issued by: Environmental Health Department, Eagle County, CO September 04, 2013 Date Customer Copy Terri Vroman CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED Work Classification: NewPermit 899 DAGGET LANE GYPSUM CO 81637- Address Owner Information Permit Status: Active Project Address 211119100003 Permit Type: OWTS Permit Permit NO. OWTS-8-13-9546 Expires: 1/2/2014 Issue Date: 9/4/2013 Parcel No. 1204 DAGGETT LN Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: (970)471-1021 Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)471-2121BROCK CONSULTING, LLC Contractor(s)Phone Primary ContractorLicense Number BROCK CONSULTING LLC (970)328-2123 Yes29-13 LAURA AND STEVEN HAGEN Permitted Construction / Details: This Brock Consulting, LLC engineer design resubmittal dated September 4, 2013 has a tank sized for up to 5 bedrooms, but the leach field is only sized for 3 bedrooms. Install per design a 1500 gallon, two compartment concrete septic tank with a cleanout between the dwelling and the tank. Use schedule 40 PVC and insulate under the driveway and any parking areas with 2” rigid insulation. The absorption field is to consist of 28 Quick 4 Infiltrator units in two trenches to provide 560 sq ft of absorption area credit or an actual area of 280 sq ft. Trench should follow the natural surface contours and be level. Rake trench bottom and sidewalls to eliminate smearing and remove any cobbles in trench bottoms and in backfill material. Provide inspection portals at each end of the trench. Maintain all required setbacks. Do not install in wet or frozen soil conditions. Call the design engineer for a final inspection before burying any of the system components. In order to receive final approval, the engineer must provide the final certification letter, photos of the installation, and as-built drawings of the system. Office Copy September 04, 2013 Issued by: Environmental Health Department, Eagle County, CO Date Terri Vroman CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED 8-13-9546 $800 600715 1001 08/28/2013 BROCK CONSULTING, LLC Professional Services November 14, 2013 VIA email: [environment@eaglecounty.us] Eagle County Building Department P.O. Box 850 Eagle, CO 81631 HICLLC 876 Mesa Drive P.O.B. 3644 Eagle, CO 81631 Direct 970-471-2121 Fax 970-328-087S brockconsulting@centurytel.net Reference: Engineering Certification Letter for Hagen/Gerard Residence Permit # OWTS 8-13-9546 1204 Daggett Lane, Gypsum, Colorado Dear Department of Environmental Health: Please accept this certification letter, as -built drawing and pictures as certification of the OWTS serving the residence at 1204 Daggett Lane, Gypsum, Colorado in Eagle County, Colorado has been installed as reflected on the As Built Drawing, attached, and constructed per Eagle County Septic Regulations by licensed septic installer Vern L. Brock (license #29-13) and general contractor/owner Hagen/Gerard. If you have any concerns with this submittal, please call me. Sincere Vern L. Brock, P.E. Brock Consulting, LLC cc: Steven Hagen, Doug Hill Attachments: AS -BUILT DRAWING, 11/13/13 Actual dimensions to Facilities, 11/13/13 o,*,D0- LICF,y Progress Pictures of 11-11-13 1- 3 o�Fss�0 A HAGEN/GERARD RESIDENCE OWTS # 8-13-9546 PROGRESS PICTURES 1204 DAGGETT LANE, GYPSUM, COLORADO DATE 11-11-2013 CLEAN OUT AT HOUSE WEST SIDE, 32 FT FROM NW CORNER SEPTIC TANK (COPELAND 1500 GAL) OUTLET PIPE WITH PROPRIETARY SCREEN) Page 1 1 MAIN LINE, 4 INCH PVC (SDR 35) AT 2% TO INFILTRATOR TRENCH 1 CONNECTION AT TRENCH 1 PER PRE MANUFACTURER INLET PORT Page 1 2 _ 1` idtf L; $ g �,. ' w -44 UPPER TRENCH #1 LOOKING NORTH EAST, DEPTH 3 FT., LEVEL Page 13 LOWER INFILTRATOR TRENCH; TYPICAL CHAMBER DEPTH 3 FT; ROCKS SCREENED FROM ALL BACKFILL OF SEPTIC SYSTEM ! TYPICAL PIPE SPECIFICATION SDR 35, 4 INCH; TRENCHES LEVEL TRENCH SIDES —TYPICAL; ROCKS REMOVED FROM BEDDING Page 14 BROCK CONSULTING, LLC ACTUAL DIMENSIONS TO FACILITIES SEPTIC TANK TO BUILDING SEPTIC TANK TO WATER LINE SEPTIC TANK TO ABSORPTION TRENCHES SEPTIC TANK TO WELL ABSORPTION TRENCHES TO BUILDING ABSORPTION TRENCHES TO WATER LINE ABSORPTION TRENCHES TO IRRIGATION ABSORPTION TRENCHES TO PROPERTY LINE BUILDING SEWER TO WATER LINE Measured November 13, 2013 Page 1 of 1 BCLLC ACTUAL (MIN. REQ'D) 20 FT (5 FT) 100 FT (10 FT) 100 FT (10 FT) NA 70 FT (20 FT) 40 FT (25 FT) NA 40 FT (10 FT) 55 FT (10 FT) Nov 11 13 08:11 p Artisan Designs 9707667445 p,1 Copeland Concrete, Inc. 28803 Highway 6 Rifle, CO 81650-9452 970-625-1112 970-625-I 1 l0 fax Sig Name [Address Grand Junction Pipe & Supply P.O Box 1849 Grand Junction, CO 51502 "PIWS7E�THE LORD" Ship To Gypsum 1204 Dagget Lane Doug 376-2511 Racking Slip Date S.O. No. 10/3 1/20I3 303 3 Customer Phone I P.O. No. I Ship Date I Ship Via f Customer Contact I 970-524-4440 1 10-4008357 1 10/31 /2013 4 rott weight Item Ordered Description 13560 R-1500 gallon .,. 1500 gallon septic tank 6 R-139000 3 effluent filter R-Gypsum Delivery charge to Gypsum Unkss Copeland Concrete delivers and «s o4r tanks we are NOT responsible for an 3 teaks Signature r. � BROCK CONSULTING, LLC Professional Services Revised September 4, 2013 HAGEN RESIDENCE 1204 Daggett Lane, Gypsum, CO 81637 PN 2111 19100 003, DESIGN CALCULATIONS FOR ABSORPTION TRENCH SYSTEM ■ REFERENCES ■ BrLLC P.O. BOX 3644 Eagle, CO 81631 Cell 970-471-2121 Fax 970-328-0875 Individual Sewage Disposal Systems, Colo. Dept. of Health, Amended 9/15/2004 Eagle County Regulations for Individual Sewage Disposal Systems (ISDS) Infiltrator Chamber Systems Septic Design and Installation, Current Edition Because of the site conditions and gentle slope, a Chamber Trench System is recommended for this site. DESIGN FLOWS Number of bedrooms = 3, Maximum daily Flow (Qmax) = 1.5 X Ave. daily flow Qave = 3 bdrms x 2 persons/bdrm x 75 gallons/person/day = 450 gpd Qmax = 450 X 150% = 675 gpd SEPTIC TANK Volume = Qmax/24hrs x 30hrs Detention V = 1406 gallons (sized for potential future 2 bedrooms in basement) Use 1,500 Gallon (2 compartment) Valley Precast, Inc. or equivalent. Each compartment 750 gallons. ABSORPTION AREA Design percolation rate was calculated to be T = 10 MPI (minutes per inch) Based on Percolation rate of 10, and Course to Fine Sand (all cobbles to be removed), a Long Term Acceptance Rate (LTAR) of 1.2 GAL/Day/sf is shown in the table (CDPHE, pg 34) as acceptable. A = Qmax/1.2gpd/sf A = 675/1.2 = 562 sf As a double check, Using Eagle County Table 5; Absorption Area = 165 SF/bedroom or 495 SF, Page 1 of 4 For conservancy, this design to use 675 SF. INFILTRATOR CHAMBER SYSTEM IN SERIAL TRENCH DISTRIBUTION State Reduction for Trenches in Chamber System is 50% Square Feet per chamber is 10.0 (Quick 4) 30"x48" Final Absorption Area Required = 562 (0.50) = 281 sf Number of Chambers = Req'd Area/10.0 sf/chamber = 281/10 = 28 Chambers Recommend to install two (2) rows of 14 chambers. * Meets Manufacturer Minimum Recommendations Given site conditions. Use 2 Rows of 14 Chambers. Product to be Infiltrator Systems, Inc. "Quick 4" Chambers INSTALLATION Install all components to the required setbacks required by regulations. No over excavation allowed for septic tank. Install septic tank level. Install the delivery pipe from the residence to the septic tank and septic tank to absorption trench. All pipe to be minimum 2% slope, Schedule 40 PVC (ASTM D 2665). Insulate under driveway or any parking area with 2" rigid insulation. Install chambers level. Connect relief pipe from trench to trench per plans. Backfill and compact the pipe trench, septic tank, and chambers to manufacturer specifications. Cover inspection lids with maximum 8-inches of soil. All covers shall be child proof (100 lb. Min.). NOTES: l . All installations shall meet the rules and regulations of the Eagle County Environmental Health Division, Chapter 4, Individual Sewage Disposal Systems. 2. The building sewer line from the house to the septic tank shall have a slope of/4 inch per foot (2%). Bends in the building sewer shall be limited to 45 degrees. 3. The septic tank shall be installed level. The tank shall have removable covers or manholes to within 8 inches of the finished grade, for inspection and cleaning. 4. Strip all topsoil in absorption bed area. Reuse for vegetative cover. 5. Excavate three (3) feet wide trenches where possible. The horizontal distance from' sidewall to sidewall between the trenches shall be a minimum of six (6) feet. NA. 6. The bottom and the sidewalls of the trenches shall be raked to eliminate smearing. 7. Assemble and install the Infiltrator Chambers in the trenches according to the manufacturer's recommendations. 8. Backfill the sidewall area with native on -site (sandy) soil for proper support. 9. Backfill the trenches with a minimum of 12 inches of tamped soil cover. 10. Avoid vehicle traffic over the system. 11. The Septic System Installation shall be inspected by the Design Engineer Backfill. I Page 2 of 4 MINIMUM DIMENSIONS TO FACILITIES SEPTIC TANK TO BUILDING SEPTIC TANK TO WATER LINE SEPTIC TANK TO ABSORPTION TRENCHES SEPTIC TANK TO WELL ABSORPTION TRENCHES TO BUILDING ABSORPTION TRENCHES TO WATER LINE ABSORPTION TRENCHES TO IRRIGATION ABSORPTION TRENCHES TO PROPERTY LINE BUILDING SEWER TO WATER LINE ACTUAL (MIN. REQ'D) 20 FT (5 FT) 100 FT (10 FT) 20 FT (10 FT) NA 30 FT (20 FT) 80 FT (25 FT) 120 FT (50 FT) 30 FT (10 FT) 60 FT (10 FT) August 22, 2013 Hagen Septic System Soils evaluation 8 ft. profile hole � h n rr�r l The above picture taken during percolation testing is indicative of the soil cot and below the proposed elevation of the absorption field. The soil type is cob gravelly, silty sand based on H-P Geotech soils report. Approximate analysis is: _ V 4 offf G !' 8 f Page 3 of 4 4-� 13 MINIMUM DIMENSIONS TO FACILITIES SEPTIC TANK TO BUILDING SEPTIC TANK TO WATER LINE SEPTIC TANK TO ABSORPTION TRENCHES SEPTIC TANK TO WELL ABSORPTION TRENCHES TO BUILDING ABSORPTION TRENCHES TO WATER LINE ABSORPTION TRENCHES TO IRRIGATION ABSORPTION TRENCHES TO PROPERTY LINE BUILDING SEWER TO WATER LINE ACTUAL (MIN. REQ'D) 20 FT (5 FT) 100 FT (10 FT) 20 FT (10 FT) NA 30 FT (20 FT) 80 FT (25 FT) 120 FT (50 FT) 30 FT (10 FT) 60 FT (10 FT) August 22, 2013 Hagen Septic System Soils evaluation 8 ft. profile hole The above picture taken during percolation testing is indicative of the soil conditions ,t�ti�ltit,�;� and below the proposed elevation of the absorption field. The soil P P p type is cobbly- ���i'DO REG/��1f%f. gravelly, silty sand based on H-P Geotech soils report. Approximate analysis b •'' L .• �,� is: Page 3 of 4 5 1 ° 'ems; o Topsoil top 1-2 ft Silty Loam 25% Fine sand 40% Fine Gravel 10% Coarse Gravel 5% Cobbles 20% The soils are conducive for a "septic" on -site wastewater treatment system, providing all cobbles are screened out of the bedding and sidewall area. No cobbles in backfill to Prevent point loading of infiltrators. This site and design will be evaluated carefully during excavation for soil conditions, and modified if they change measurably as necessary. •,.....,. RFGI <<< g �N l ag. e �0 •MN• �x Page 4 of 4 oaf, NA E- �f/{p:.vlett� I au•lel,Cjn} ueo®6 up ins uooMooaq C L 8 0— q Z� (O L 6) X v 3 O a V �J O-10 0 `,,1 N n O O 31 O d ------_—_--------_----- Z l Z— l L V (O L 6) 301330----------- - ----- w G , 9 G q 0 (3v � 010 o 310 V 3 5- OQ ©Q 1 L � � � � Z ri/ ' -----------:53111 3JN3a3j3a lVNa31X = :]A1zJQ dS3 W 9L8 iJ 1 �{ 01-1 E3e ---- _--- AB SNO5N34 31V0 'ON ------.- • Z O V � O O mow wl O LL O Z O �st now i %LJ� a tW Ljj ts. tL LU V11 gar Qz >� r� ra rQ -sin � -? L, o N 4 p,rp 1<1 R v �- All N o 01 ;t�i 'p-- MAAjFl Nods o � A � s T a Fri F n \, 3rTt TE- � m r � T 0 z � © ` 4 PPROVED:� DATE: PI AN — C/1 ME BY: TERNAL REFERENCE FILES: �m — _ _ — p6.1 till i�► 0.0 Oo� ---- EAGLE COUNTY, COLORADO LLC 876 MESA DRIVE EAGLE, COLORADO 81631 OFFICE (970) 471 —21 21 FAX (970) 328-0875 brook con su It in g(Mccen to ryt el.n et