Loading...
HomeMy WebLinkAbout2735 Upper Cattle Rd - 239127100003 - OWTS-10-13-9842Work Classification: ReplacePermit 2735 UPPER CATTLE CREEK RD EL JEBEL AREA CO Address Owner Information Permit Status: Under Review Project Address 239127100003 Permit Type: OWTS Permit Permit NO. OWTS-10-13-9842 Expires: N/A Issue Date: Not Issued Parcel No. 2735 UPPER CATTLE RD Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: (970)963-2072 Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) Contractor(s)Phone Primary ContractorLicense Number AVALANCHE EXCAVATION (970)379-7815 Yes53-13 DAVID ANDERSON Permitted Construction / Details: Installation is granted for a two compartment septic tank size of at least 1000 gallons, to service this 3 bedroom home. This permit does not allow for any work to be done on the existing soil treatment area for which we have no records. The new tank can be made of concrete or plastic. The existing metal tank serving the property is to be pumped and then removed for proper disposal, so that the new tank can be placed in this location. Use 4 inch PVC piping for the building sewer of at least schedule SDR 35 and add a cleanout between the house and the tank. Do not use any 90 degree elbows on the building sewer between the house and the tank. If the building sewer from the house to the tank or the effluent line from the septic tank to the leach field goes under any areas for parking or the driveway, use a minimum of schedule 40 pipe or sleeve the sewer pipe with schedule 40 pipe. Add extra insulation if there is less than 40 inches of backfill soil cover over the pipe. Install 14 inch sanitary tees on both the inlet pipe and the outlet pipe inside the septic tank. Maintain all required setbacks. Do not install in wet or frozen soil conditions. Call Eagle County Environmental Health for a final inspection before burying any of the system components. If Eagle County is not able to conduct a final inspection of the system due to time constraints, photos of the installation, and as-built drawings of the system will be required in order to finalize this permit. Issued by: Environmental Health Department, Eagle County, CO October 16, 2013 Date Customer Copy Terri Vroman CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED Work Classification: ReplacePermit 2735 UPPER CATTLE CREEK RD EL JEBEL AREA CO Address Owner Information Permit Status: Under Review Project Address 239127100003 Permit Type: OWTS Permit Permit NO. OWTS-10-13-9842 Expires: N/A Issue Date: Not Issued Parcel No. 2735 UPPER CATTLE RD Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: (970)963-2072 Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) Contractor(s)Phone Primary ContractorLicense Number AVALANCHE EXCAVATION (970)379-7815 Yes53-13 DAVID ANDERSON Permitted Construction / Details: Installation is granted for a two compartment septic tank size of at least 1000 gallons, to service this 3 bedroom home. This permit does not allow for any work to be done on the existing soil treatment area for which we have no records. The new tank can be made of concrete or plastic. The existing metal tank serving the property is to be pumped and then removed for proper disposal, so that the new tank can be placed in this location. Use 4 inch PVC piping for the building sewer of at least schedule SDR 35 and add a cleanout between the house and the tank. Do not use any 90 degree elbows on the building sewer between the house and the tank. If the building sewer from the house to the tank or the effluent line from the septic tank to the leach field goes under any areas for parking or the driveway, use a minimum of schedule 40 pipe or sleeve the sewer pipe with schedule 40 pipe. Add extra insulation if there is less than 40 inches of backfill soil cover over the pipe. Install 14 inch sanitary tees on both the inlet pipe and the outlet pipe inside the septic tank. Maintain all required setbacks. Do not install in wet or frozen soil conditions. Call Eagle County Environmental Health for a final inspection before burying any of the system components. If Eagle County is not able to conduct a final inspection of the system due to time constraints, photos of the installation, and as-built drawings of the system will be required in order to finalize this permit. Office Copy October 16, 2013 Issued by: Environmental Health Department, Eagle County, CO Date Terri Vroman CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED Oct 151310;23a p.3 DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225.6136 4uwsti.caaicc0un1V. us P.O. Box 179 500 Broadway Eagle, 00 81631 www.eaglecounty.us *# x*## #:k:k:K�#*:}::k#####*### #kW%:#:C#a%*Xr•�::k:k##kk%:*#:Kk#:k:h•�::k.+,ek:k*:k#r:k#:kk 9c:k*:I::k#:G:%:kl:k:k:k:k:k#k* *:k:kk* PERMIT APPLICATION FOR ONSITE WASTEWATER TREATMENT SYSTEM OWTS PERMIT # — —— BUILDING PERMIT # INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED) FEESCHEDULE APPLICATION FEE $800.00 MAJOR REPAIR FEE $800.00 MINOR REPAIR FEE 00.00 This fee includes the OWTS Permit, Site Evaluation (Percolation Test, or Soil Profile Observation) and Final Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction site visit or consultation is needed. The re -inspection fee is $11,35.00 Make all remittance payable to: Eagle County Treasurer. Property Owner: Phone: 6 %R9-5?iT— 42ZZ Mailing Address.-4n --L 47, email ES- eawvr Registered Professional Engineer: Xk Phone: Applicant or Contact Person:T1id, Phone: Licensed Systems Contracto.�i�14�I� License # Company / DBA.-Oejo Y�� Phone: 394-0�:) 07K Mailing Address.%, _r !/& 19Cz Zlol Fz Permit Application is for: New Installation Alteration 'epair Location of Proposed Onsite Wastewater Treatment System: Legal Description:. TZ O`,oz7 7 Tax Parcel Number: ����e���0�� I--ot Size: .i .Z% ,44xw Assessor's Link: www.caglecountv.us/pati -1 Physical Address: ge / Building Type: Residential / Single Family Residential / Multi Family Number of Bedrooms: Number of Bedrooms: Commercial / Industrial* Type of Use: `These systems require design my a Registered Professional Engineer Type of Water Supply: Private Well Spring Surface �lic If Public Name of Supplier: V - Applicant Signature: Office Use Only Amount Paid: Receipt #: Check #: Date: Oct 151310:23a p.4 ,for s�� mr �y �� .�•Q� z-.�.�,t� �,�,��/ � 6 /0 3 ISDS Final Ins ectlon Completeness Form _ Tank is %-SOOgalions. Tank material /ov Tank (1) is located 07S /Oft. and J90 degrees from IVA Tank (2) is located ft. and degrees from Tank set level. ,Tank lids within 8" of finished grade. Size of field ft' ___.9_ units lineal ft. Technology a n Cu»1en - re -dk- S C , Cleanout is installed in between tank and house and-ene-evmv? K "T° that goes down 14 inches in the inlet and outlet of the tank. Effluent filter on outlet-(G or No Inlet and outlet is sealed with tar tape, rubber gasket, etc. :7- o e )140- 101A) / 70 — oca 7 f . X— Tank has two compartments with the larger compartment closest to the house. C Measure distance and relative direction to field. FOLV� Ce Depth of field ? ft. AIppe-1--f 7� �� e�s� o a0',R►�c � s Fe Soil interface raked. /U B Inspection portals within each trench. /V11f4 k Proper distance to setbacks. Chambers properly installed as per manufacturers specifications. (Chambers Iatched, end plates proper] installed, rocks removed from trenches, etc.) Splash plate(s) installed at trench inlets. Type of pipe used for building sewer line��Ieach field .—� Other e .�t t'o drw i�; a�r1` S'A � d IGt „ Inspection meets requirements. Copy form to installer's rile if recommendations for improvement were suggested. ACTION TAKEN. Setbacks: Well Potable House Property Lake Dry Tank Drain Field Water Lines line Stream Gulch Field 100 25 20 10 50 25 10 Tank 50 10 5 10 50 10 '" 10 ■��Il■■ ■ball■■ �? rip — SECTION:3.20.065 `QVQL/TYlaZIMPS SIAOF 19,7 FM1775 0809 Product information presented ® ZD Supersedes here reflects conditions at time �//A )7 %Q ® 0308 of publication. Consuftfac- LJ/1�/ L tory regarding discrepancies or visit our web site: inconsistencies. MAIL TO. P0, BOX 16347 • Louisville, KY 40256-0347 SNIP TO. 3649 Cane Run Road - Louisville, KY 40211-1961 www.zoetter.com (502) 778-2731 - 1(800) 928-PUMP • FAX (502) 774-3624 ZOELLCR ONSITE WASTEWATER PRODUCTS BY-PASS PROTECTION Sleeve remains in the outlet tee when the main filter is removed for servicing. Solids are prevented from leaving the tank. GASKETED SEAL Rubber gasket ensures that all effluent passes through the filter, not around it. Provides protection in all commonly found 4" outlet tees. DEEP PLEATED CONSTRUCTION -- Design adds mom effective filter area than any other 4" filter on the market Pleats retain solids to aid in servicing. CLEAR ZONE ACCESS, Once installed in the tee, filter pulls effluent from only the "clear zone" of the tank. NSF -.. N cemeed to ANSI -NSF a Covered by US Patent Nos. I 6,136,190; 6,331,247; 6,495,040. TWIST LOCK MECHANISM Inner cartridge is held firmly in place, but can be easily removed for servicing. LOCKING TAB Zoeller invented the locking tab to prevent the filter from floating out and keep the by-pass sleeve in place when servicing. 1 rt SUPERIOR FILTRATION ! 1 132 linear feet of 1/16" filtra- tion is located below the water �! line, making the filter 100% i effective. Available with sanitary tee and filter complete. 1;70-0144 © Copyright 2009 Zoeller Co. All rights reserved. Application: Single family homes. Filter Area: 132 Linear Feet of 1/16" filtration. Flow Rate: 1,000 GPD. Two or more filters may be connected with a manifold for higher flow applications. Material: All materials are noncorrosive in the septic tank environment. Sleeve is PVC, primary filter is polypropylene, and filter connection element is neoprene. Easy to install or retrofit: The Zoeller Septic System Filter fits inside any 4" sanitary tee. Slide the filtercartridge into the filter sleeve. Slide the assembled cartridge and sleeve into the sanitary tee at the tank's outlet. Ensure the sleeve tab is pointing toward the outlet of the septic tank before filter placement into the tee. The drain field is now protected from solids greater than 1116". AND LOCKABLE LATCH li EXTENSION HANDLE SLEEVE OUTLET RLTERING CONNECTION ELEMENT NOTE Is, 4- SANITARY TEE OTAL LENGTH OF FILTER 4' DRAINAGE PIPE SK1972 CARTRIDGE Adding an extension handle: A 1 /2" PVC pipe can EiXothe tate and local plumbing codes may require be attached to the top of the filter with a stainless steel screw. Cut iquid penetration. Forexample, 25% -45% quid depth or 9" off the tank bottom. off to appropriate length below the lid. Easy to maintain: The filter can be maintained by rotating the cartridge counterclockwise out of the locking tabs and removing for cleaning. The sleeve should remain in the sanitary tee while cleaning the cartridge. To clean, hold cartridge over septic tank opening and rinse with a hose until clean, washing filtered solids back into the septic tank. In addition, spray off any solids that have accumulated on the inside of the sleeve. The Zoeller filter should be cleaned each time the septic tank is pumped or when the need is indicated by a high water level in the tank or slow flows from the house. The secondary filter sleeve should be cleaned whenever the tank is pumped. For installations that exceed the design flow rate of the filter or in applications where the septic tank is undersized, more frequent cleanings may be required. It is best when the filter is inspected and serviced as part of a regular septic tank maintenance routine. Troubleshooting, repair, and replacement: Follow the install and maintenance instructions above. For replacement components, call 1-800-928-PUMP. Lifetime Warranty: Every Zoeller filter is guaranteed to be free from defects in materials and workmanship for the lifetime of the homeowner/purchaser. Free repair or replacement, excluding labor, will be made on return of the filter prepaid to the factory. This warranty is limited to product proven to be free from abuse or improper installation. ALL ZOELLER ONSITE PRODUCTS MUST BE INSTALLED IN ACCORDANCE WITH PLUMBING AND HEALTH DEPARTMENT CODES. Distributed By: PU/v!P !0 1-800-928-PUMP www.zoeller.com 0 Copyright 2009 Zoeller Co. All rights reserved. 3 I�'j{ yV l F-� v a C1 / N r_ n 00 -73 co o i y v s r� f -73 Sp �i ly f ti V