HomeMy WebLinkAbout20 Forest Rd - 218923301001 - OWTS-10-14-11660Work Classification: NewPermit
CO
Address Owner Information
Permit Status: Active
Project Address
218923301001
Permit Type: OWTS Permit
Permit NO. OWTS-10-14-11660
Expires: 2/17/2015 Issue Date: 10/20/2014
Parcel No.
20 Forest RD
Private Wastewater
System
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone: (970)404-1176
Cell:
Inspection
For Inspections call: (970) 328-8755
Inspections:
IVR
PhoneEngineer(s)
Contractor(s)Phone Primary ContractorLicense Number
HOLMES EXCAVATION LLC (970)947-1063 Yes45-14
KAJ SEELBINDER
Permitted Construction / Details:
Install the OWTS exactly as designed by All Service Septic, LLC as depicted on the design report
stamped, signed and dated October 8, 2014. The design capacity is for a minimum of two bedrooms in
accordance with minimum residential design criteria specified in WQCC Regulation 43. Unfinished areas
were not included into the design.
System consists of a 1,000 gallon two compartment Valley Precast septic tank with effluent screen placed
on the outlet tee and 600 square feet of soil treatment area credit via the installation of 36 Infiltrator Quick
4 chambers placed in three shallow trenches with 32 chambers in each trench that will receive effluent
equally from the installation of a distribution box. Access to the septic tank manholes and the
distribution box must be brought to grade. Inspection portals are required to be placed at both ends of
each trench.
Do not install in wet weather or frozen ground. Contact the design engineer to conduct all inspections
necessary in order to certify the proper installation of the OWTS. Final certification must be submitted to
and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the
dwelling.
Issued by: Environmental Health Department, Eagle County, CO
October 20, 2014
Date
Customer Copy
Terri Vroman
CONDITIONS:
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH
LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
Work Classification: NewPermit
CO
Address Owner Information
Permit Status: Active
Project Address
218923301001
Permit Type: OWTS Permit
Permit NO. OWTS-10-14-11660
Expires: 2/17/2015 Issue Date: 10/20/2014
Parcel No.
20 Forest RD
Private Wastewater
System
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone: (970)404-1176
Cell:
Inspection
For Inspections call: (970) 328-8755
Inspections:
IVR
PhoneEngineer(s)
Contractor(s)Phone Primary ContractorLicense Number
HOLMES EXCAVATION LLC (970)947-1063 Yes45-14
KAJ SEELBINDER
Permitted Construction / Details:
Install the OWTS exactly as designed by All Service Septic, LLC as depicted on the design report
stamped, signed and dated October 8, 2014. The design capacity is for a minimum of two bedrooms in
accordance with minimum residential design criteria specified in WQCC Regulation 43. Unfinished areas
were not included into the design.
System consists of a 1,000 gallon two compartment Valley Precast septic tank with effluent screen placed
on the outlet tee and 600 square feet of soil treatment area credit via the installation of 36 Infiltrator Quick
4 chambers placed in three shallow trenches with 32 chambers in each trench that will receive effluent
equally from the installation of a distribution box. Access to the septic tank manholes and the
distribution box must be brought to grade. Inspection portals are required to be placed at both ends of
each trench.
Do not install in wet weather or frozen ground. Contact the design engineer to conduct all inspections
necessary in order to certify the proper installation of the OWTS. Final certification must be submitted to
and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the
dwelling.
Office Copy
October 20, 2014
Issued by: Environmental Health Department, Eagle County, CO Date
Terri Vroman
CONDITIONS:
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH
LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
Work Classification: NewPermit
338 CLEVELAND PLACE
CARBONDALE CO 81623
Address Owner Information
Permit Status: Active
Project Address
218923301001
Permit Type: OWTS Permit
Permit NO. OWTS-10-14-11660
Expires: 8/22/2015 Issue Date: 4/24/2015
Parcel No.
20 Forest RD
Private Wastewater
System
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone: 970-404-1176
Cell:
Inspection
For Inspections call: (970) 328-8755
Inspections:
IVR
PhoneEngineer(s)
(970)309-5259All Service Septic, LLC
Contractor(s)Phone Primary ContractorLicense Number
HOLMES EXCAVATION LLC (970)947-1063 Yes23-15
RAINBOW, VICKI - SEELBINDER, KAJ
RAINBOW, VICKI - SEELBINDER, KAJ
Permitted Construction / Details:
Install the OWTS exactly as designed by All Service Septic, LLC as depicted on the design report
stamped, signed and dated October 8, 2014. The design capacity is for a minimum of two bedrooms in
accordance with minimum residential design criteria specified in WQCC Regulation 43. Unfinished areas
were not included into the design.
System consists of a 1,000 gallon two compartment Valley Precast septic tank with effluent screen placed
on the outlet tee and 600 square feet of soil treatment area credit via the installation of 36 Infiltrator Quick
4 chambers placed in three shallow trenches with 12 chambers in each trench that will receive effluent
equally from the installation of a distribution box. Access to the septic tank manholes and the
distribution box must be brought to grade. Inspection portals are required to be placed at both ends of
each trench.
Do not install in wet weather or frozen ground. Contact the design engineer to conduct all inspections
necessary in order to certify the proper installation of the OWTS. Final certification must be submitted to
and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the
dwelling.
Issued by: Environmental Health Department, Eagle County, CO
May 04, 2015
Date
Customer Copy
Terri Vroman
CONDITIONS:
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN
BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
Work Classification: NewPermit
338 CLEVELAND PLACE
CARBONDALE CO 81623
Address Owner Information
Permit Status: Active
Project Address
218923301001
Permit Type: OWTS Permit
Permit NO. OWTS-10-14-11660
Expires: 8/22/2015 Issue Date: 4/24/2015
Parcel No.
20 Forest RD
Private Wastewater
System
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone: 970-404-1176
Cell:
Inspection
For Inspections call: (970) 328-8755
Inspections:
IVR
PhoneEngineer(s)
(970)309-5259All Service Septic, LLC
Contractor(s)Phone Primary ContractorLicense Number
HOLMES EXCAVATION LLC (970)947-1063 Yes23-15
RAINBOW, VICKI - SEELBINDER, KAJ
RAINBOW, VICKI - SEELBINDER, KAJ
Permitted Construction / Details:
Install the OWTS exactly as designed by All Service Septic, LLC as depicted on the design report
stamped, signed and dated October 8, 2014. The design capacity is for a minimum of two bedrooms in
accordance with minimum residential design criteria specified in WQCC Regulation 43. Unfinished areas
were not included into the design.
System consists of a 1,000 gallon two compartment Valley Precast septic tank with effluent screen placed
on the outlet tee and 600 square feet of soil treatment area credit via the installation of 36 Infiltrator Quick
4 chambers placed in three shallow trenches with 12 chambers in each trench that will receive effluent
equally from the installation of a distribution box. Access to the septic tank manholes and the
distribution box must be brought to grade. Inspection portals are required to be placed at both ends of
each trench.
Do not install in wet weather or frozen ground. Contact the design engineer to conduct all inspections
necessary in order to certify the proper installation of the OWTS. Final certification must be submitted to
and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the
dwelling.
Office Copy
May 04, 2015
Issued by: Environmental Health Department, Eagle County, CO Date
Terri Vroman
CONDITIONS:
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN
BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.eaglecounly.us
OWTS PERMIT #
INCOMPLETE APPLICATIONS WILL
APPLICATION FEE $800.00 MAJOR
This fee includes the OWTS Permit, Site
Inspection. Additional fees may be charge
consultation is needed. The re -inspection fee
Make all remitta
Property Owner: "� I
Mailing Address: 3
Registered Professional Engineer:
Applicant or Contact Person:
Licensed Systems
Company / DBA•
Mailing Address:
Permit Application is for:
Location of Proposed Onsite W
Legal Description:
Tax Parcel Number: a, ` b
Assessor's Link: www.eaalecou
PhysicalAddress: O 'Dl, 0
Building Type: Residential /
Residential /
Commercial / ]
*These syste�ms'requir
Type of Water Supply: Private
If Public Name of Supplier:
Applicant Signature:
Office Use Only co
Amount Paid: Receipt
P.O. Box 178
500 Broadway
Eagle, CO 81631
www.eaglecounty.us
EAGLE COUNTY
BUILDING PERMIT #
iOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEE SCHEDULE
tEPAIR FEE �W 00 MINOR REPAIR FEE 00.00
evaluation (Percolation Test, or Soil Profile Observation) and Final
i if a re -inspection is necessary, or a pre -construction site visit or
is $135.00
ice payable to: Eagle County Treasurer. �`
.: r S 'fie �ItJ; h �a holrte: � 7 � _. 4C T- 11 7 4
le�Q, email V--oL)
Mo
t
Phone: _`-20 - Ct c4o.3
License # `-'S
�-UC40'1 Phone: y ` ~, I p
.LN
�A.�C, Co email
Alteration Repair
Treatment System: �s A o t-A{ A tft- �"
0-
#e Family
Family
Lot Size: ZS citr`CS
Number of Bedrooms:
Number of Bedrooms:
d* Type of Use:
my a Registered Professional Engineer
0
Spring Surface Public
Check #• 1l _ Date: D / / -1
lopq - d �
H01MES EXCAVATION & CONCRETE INC.
P.O. BOX 1269
CARBONDALE, COLORADO 81623
970-963-2007
Terri:
Enclosed is the permit application for the renewal of the Seelbinder
septic system permit. Carla Ostberg is the engineer for the project.
I also have submitted my application for a 2015 OWTS contractor
license, along with the appropriate checks. If you need anything else
please contact me at 963-2007 office 379-1691 cell phone.
Thank You
0 A
Bobby Holmes
RM
APR 2 0 20151
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970)328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.eacllecounty.us
D
C C�C0VE
APQX`
Eagle, CO 81631
www.e lewunty.us
EAGLE COUNTY
APPLICATION FOR ON -SITE WASTEWATER TREATMENT SYSTEM (OWTS) PERMIT
INCOMPLETE APPLICATIONS MAY NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEESCHEDULE
APPLICATION FEE FOR NEW OWTS OR MAJOR REPAIRS $800.00 MINOR REPAIR FEE $400.00
Fee includes the design review, permitting and maintenance of OWTS records
Make all checks payable to: Eagle County Treasurer ,,
Property Owner: ve\ce`� �CG�bi ��'' Phone: Q 7y 40(4
Owner Mailing Address: 33 $ M t O tWO\ i email: KOO
Co.Noowdd�c._
Professional Engineer: II Phone:
Applicant / Contact Person: Phone: -` J I (r C
Licensed Systems Contractor Name / Company:.ko\htJ �.
Contractor Mailing Addres30 U-.)' C"0Ax'> kt,(c. Contractor License #: �14
?• 3
Contractor Phone Number: 9Cc ' goo1 email: 6Whw
OWTS Permit Application is for: New Installation Alteration Repair
Tax Parcel Number: _� I8C,; 133 ok ook Lot Size:
Assessor's Link: www.eaglecounty.us/patie/
Physical Address: 0 ol-C� irlf`es-a-Woohdok CEO �b 3
Legal Description:
Building Type: -\-<' Residential / Single Family
Residential / Multi Family
Number of Bedrooms:
Number of Bedrooms:
Commercial / Industrial Type of Use:
*As of 06/27/2014, all systems require design by a Registered Professional Engineer
Type of Water Supply: i" Private Well Spring Surface Public
If Public, Name of
Applicant Signature: _
*******************
Office Use Only: OWTS PERMIT #
Date:
�1(/C) J
BUILDING PERMIT #
Amount Paid: Receipt #: Check #: Date:
OWTS PERMIT # �f -/ V — 11 [
INCOMPLETE APPLICATIONS WILL
APPLICATION FEE $SQd,00 MAJOR
This fee includes the OWTS Permit, Site
Inspection. Additional fees may be charge
consultation is needed. The re -inspection fee
�)Make all remitta
Property Owner:
Mailing Address:
Registered Professional Engineer:
t
Applicant or Contact Person:
Licensed Systems Contractor:
Company / DBA•klc4lo1—
Mailing Address:
1. Box 179
Broadway
;. CO 81631
wlecounty.us
[SITE WASTEWATER TREATMENT SYSTEM
BUILDING PERMIT # fdL- S - 1--1 � j — // f �(p
JOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEE SCHEDULE
tEPAIR FEE $M.00 MINOR REPAIR FEE $400.00
Evaluation (Percolation Test, or Soil Profile Observation) and Final
I if a re -inspection is necessary, or a pre -construction site visit or
is $135.00
ice payable to: Engle County Treasurer.
., r S ee t�, �ia•�hoiie: �.'� � �a �- �17 �
emailNA
1 Seet�hde4- ���°`�• tOM
Tt) bw-m 0 tcvwn* ,C, co,
Permit Application is for:
Location of Proposed Onsite Wastt
Legal Description:
Tax Parcel Number: I\. b C�
Assessor's Link: wwwxaidecounty
Physical Address: a
Building Type: Residential !
Residential /
Commercial / 1
*'These systems requir
Type of Water Supply: Private
If Public Name of Supplier:
Applicant Signature:
rhoneet
L Phone: R20 - Ci 4 �•t
License # �S
Phone: q 7 U C` (4) -
amail 6 rl�,3 4V "��
dallation Alteration Repair
Treatment System:L,!t 4- 6 0 tA1 A %- Nclrf-
+ Y',
e Family
Family
Lot Size: ZS c.l-fo
Number of Bedrooms:
Number of Bedrooms:
d* Type of Use:
my a Registered Professional Engineer
Spring Surface Public
Office Use Only 00
Amount Paid- Receipt Check #:
r 01/ tf — td .Qif2i.Z.�(.-4 0��
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.eaglecounty.us
RAYMOND P. MERRY, REH
Director
June 23, 2015
Kaj Seelbinder
338 Cleveland Place
Carbondale, CO 81623
RE:Final approval of septic permit OWTS-10-14-11660;Tax parcel #218923301001;
Property location: 020 Forrest Rd, Carbondale area
Kaj:
This letter is to inform you that the above-referenced septic permit has been inspected and
finalized.This permit was approved and sized for a 1 bedroom dwelling.Additional information
about the maintenance your septic system needs as well as information about private wells can be
accessed through web site links provided on the Environmental Health Department’s home page
at http://www.eaglecounty.us/envHealth/
Be aware that changes in the use of your property or alterations of your building may
require commensurate changes to,or relocation of,your septic system.Landscape features,
trees with tap roots,irrigation systems and parking areas above the drain field can cause
premature system failure.It is equally important that you notice and immediately repair
dripping faucets and hissing toilets as this will certainly cause the system to fail.By
following a few simple guidelines,like avoiding grease or other additives down the drain and
making sure your septic tank is on a pumping schedule,your system has been designed to
last for many years.
If you have any questions regarding this information,please contact us at (970)328-8755 and
reference the OWTS septic permit number.
Sincerely,
Terri Vroman
Administrative Technician IV
cc:OWTS permit folder
Energov electronic file
Bobby Holmes
Carla Ostberg
October 8, 2014 Project No. C1103
Kaj Seelbinder
kajseelbinder@yahoo.com
Subsurface Investigation and Onsite Wastewater Treatment System Design
1-Bedroom Residence / 2-Bedroom OWTS Design
020 Forest Road
Eagle County, Colorado
Kaj,
ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater
treatment system (OWTS) design for the proposed residence. The property is located outside of
Carbondale, in an area where OW TSs and wells are necessary. The property consists of 35 acres and
the legal description is Lot 5, Coulter Creek Ranches.
SITE CONDITIONS
A 1-bedroom, single-family residence is proposed. Native vegetation, including aspen trees, exists in the
proposed soil treatment area (STA). The property slopes to the north. A well has been drilled on the
south central portion of the property and is greater than 50-feet from the proposed septic tank and
greater than 100-feet from the proposed STA.
SUBSURFACE
The subsurface was investigated on October 6, 2014 by digging two 8-foot deep soil profile test pit
excavations (Test Pits).
The materials encountered in Test Pit #1 consisted of dark brown, moist, organic topsoil to 18-inches,
underlain by medium brown, moist, silty loam with granular structure shape, moderate structure grade,
and firm consistence to 6-feet, underlain by medium brown, moist, dense clayey, silty loam with reddish
brown to black mottles to a maximum depth explored of 8.0-feet. No bedrock or groundwater was
encountered.
The materials encountered in Test Pit #2 consisted of dark brown, moist, organic topsoil to 18-inches,
underlain by medium brown, moist, silty loam with granular structure shape, moderate structure grade,
and firm consistence with 2 to 3-inch diameter cobbles to a depth of 3-feet, underlain by similar material
with 4 to 6-inch cobbles to a maximum depth explored of 8.0-feet. No bedrock or groundwater was
encountered.
A long term acceptance rate (LTAR) of 0.5 gallons per square foot, will be used to design the
OWTS, in accordance with Table 10-1 Soil Type 2A presented in the Eagle County On-Site
Wastewater Treatment System Regulations, adopted May 13, 2014.
Page 2
Test Pits observed October 6, 2014
Profile in the area of the foundation
Digging Test Pit 1, looking northeast
Page 3
Test Pit #1
Test Pit #2
DESIGN SPECIFICATIONS
The OWTS design will be based on 2-bedrooms, as required by Eagle County On-Site Wastewater
Treatment System Regulations. Eagle County does not require the OWTS to be designed to accommodate
potential future bedrooms in an unfinished area of the residence, at this time. If bedrooms are added in the
future, the OWTS will need to comply with applicable regulations at that time.
An average daily wastewater flow of 300 GPD will be used. The OWTS will utilize gravity flow to
gravelless chamber trenches. The system installation will include a 1000-gallon, two-compartment
concrete septic tank with an effluent filter on the outlet tee. Effluent will gravity flow to a distribution box,
which must be accessible from grade. Flow levelers must be used in the distribution box to equalize the
flow to each trench. The soil treatment area will consist of three rows of 12 ‘Quick 4’ Infiltrator®
chambers. Inspection ports are required at the beginning and ends of each trench.
The component manufacturers are typical of applications used by contractors and engineers in thi s area.
Alternatives may be considered or recommended by contacting our office. Construction must be
according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided
by Eagle County Environmental Health Department, and this design.
Page 4
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed are of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be plated over
the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Livestock should not graze on the STA. Plumbing fixtures should be
checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or
leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, air release valves and weep holes must be installed to allow pump lines to
drain to minimize risk of freezing. The pump shall be connected to a control breaker separate from the
high water alarm breaker and from any other control system circuits. Excavation equipment must not
drive in excavation of the STA due to the potential to compact soil. Extensions should be placed on all
septic tank components to allow access to them from existing grade. Backfill over the STA must be
uniform and granular with no material greater than minus 3-inch.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be
performed before backfill, after placement of OWTS components. Septic tanks, distribution devices,
pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic,
LLC should be notified 48 hours in advance to observe the installation.
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be
according to the county regulations. Requirements not specified in this report must follow applicable
county regulations. The contractor should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working. Licensing of Systems Contractors
may be required by county regulation.
Page 5
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By:
Carla Ostberg, MPH, REHS
Liability Clause: Under no circumstances whatsoever shall the liability of ALL SERVICE septic, LLC, in connection with
any contract, directly or indirectly, exceed the total amount paid by the client to ALL SERVICE septic, L LC for the services
and/or goods which are the subject of the contract in connection with which the liability arises.
May 30, 2015 Project No. C1103
Kaj Seelbinder
kajseelbinder@yahoo.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
020 Forest Road
Eagle County, Colorado
OWTS Permit 10-14-11660
Kaj,
ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS)
on May 26, 2015 for the subject property. Holmes Excavation installed the system.
The installation included a new 1000-gallon, two-compartment Roth® poly septic tank with an effluent
filter on the outlet tee. This filter must be cleaned annually, or as needed.
Effluent gravity flows to a distribution box, accessible from grade, with flow equalizers. Effluent is
distributed to three gravelless chamber trenches. Each trench consists of 12 ‘Quick 4’ Infiltrator®
chambers for a total of 432 square feet of infiltrative area.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are
made to the OW TS in the future. Any additional OWTS construction must be according to the county
regulations.
LIMITS:
Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By:
Carla Ostberg, MPH, REHS Richard H. Petz, P.E.
Clean out
Inlet tee Outlet tee
Outlet line of septic tank (before risers) View of distribution box and first trench
Distribution box (before installation of flow equalizers)
Photos provided by installer
Risers on septic tank Inlet tee
Effluent filter
View of distribution box and trenches Distribution box
Flow equalizers (speed levelers) Distribution box filled with water for testing
After backfill
832‐R‐13‐002