HomeMy WebLinkAbout777 Buck Point Dr - 218927201004 - IS-2574-06INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
Telephone: (970) 328-8755
P.O. Box 179 - 500 Broadway, Eagle, CO 81631
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE.
PERMIT# 2574A-06
BUILDING PERMIT#
OWNER: Cynthia Meyers/Damon Onoroski
PHONE: 970-778-4209/309-3536
MAILING ADDRESS: 777 Buck Point Drive, Carbondale, CO 81623
APPLICANT: SAME AS ABOVE
PHONE: SAA
SYSTEM LOCATION: 777 Buck Point Drive
TAX PARCEL NO. 218927201004
LICENSED INSTALLER: ASPEN DIGGER
LICENSE NO. 21-06
PHONE: 970-963-2157
DESIGN ENGINEER: N/A
PHONE: N/A
NOTE: SYSTEM SIZED TO ACCOMMODATE A TOTAL OF 3 BEDROOMS. ANEW BARN IS BEING CONNECTED TO THE EXISTING
ISDS INSTALLED IN 1995 UNDER PERMIT #1479 THAT WAS SIZED FOR THREE BEDROOMS. OUR RECORDS INDICATE THE
EXISTING ISDS CONSISTS OF A 1,000 GALLON CONCRETE TANK WITH 968 FEET OF ABSORPTION AREA VIA 27 INFILTRATOR
CHAMBERS IN A TRENCH CONFIGURATION.
INSTALLATION GRANTED FOR THE FOLLOWING: RUN A BUILDING SEWER FROM THE NEW BARN TO THE EXISTING
SEWER LINE. NO 90 DEGREE CONNECTIONS ARE ALLOWED. PROVIDE A CLEANOUT WITHIN 5' OUTSIDE OF THE NEW BARN
AND EVERY 100' IF NECESSARY. EITHER TIE INTO THE TANK ON THE SIDE OF THE FIRST COMPARTMENT OR WITH A Y TO
THE PIPE THAT WILL CONNECT TO THE SEPTIC TANK.
SPECIAL INSTRUCTIONS:
• Call Eagle County for final inspection prior to back -filling any portion of the installation or with any questions.
• The Building Certificate of Occupancy will not be issued until the septic system has been inspected and approved.
ENVIRONMEIHEALTH APPROVAL:
DATE: 11/06/06
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN
BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS
UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
COMMENTS:
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A
RE -INSPECTION WHEN WORK IS COMPLETED.
ENVIRONMENTAL HEALTH APPROVAL:
DATE:
Department of
Environmental Health
Eagle (970) 328-8755
Fax: (970) 328-8788
El Jebel (970) 704-2700
TOLL FREE: 800-225-6136
P.O. Box 179
500 Broadway
Eagle, CO 81631
www.eaglecounty.us
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ISDS Permit # Building Permit #
INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEESCHEDULE
APPLICATION FEE $350.00
This fee includes the ISDS Permit, Site Evaluation (Percolation Test, or Soil Profile Observation) and
Final Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction
site visit or consultation Is needed. The re -inspection fee Is $55.00. The pre -construction site visit fee
Is $85.00. Make all remittance payable to: Eagle County Treasurer,
I - Property Owner: Id L-w one: -1-70 IN- 4202 / -30�
Mailing Address: -71 'GLAUL
Applicant/Contact Person:
Phone: - Q vc� -
Licensed Systems Contractor: 4a,(f,,�,-License
Company/DBA: Phone:
Mailing Address: __? -7-7
- L(
Permit Application is for: F- New Installation fV_ Alteration F- Repair
Location of Proposed Individual Sewage Disposal System:
Legal Description:
Tax Parcel Number: j ) 'S � oc� Lot Size:
Assessor's Link: www.eaglecounty,us/patiie
Physical Address: �' 6D
Building Type Residential/Single Family Number of Bedrooms:
Type:
Family Number of Bedrooms:
F- Commercial/Industrial* Type of Use: Uol
*These systems require design by a Registered Professional Engineer
Type of Water Supply: Private Well F- Spring f- Surface I- Public
If Public Name S
o Supplier,-.
C) u
Applicant Signature : , I , /i ( ,, , , 1117'
Office Use Only
Amount Paid: 1Receipt*: cl Check*: i Date: �/C)
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970)328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.eaglecounty.us
EAGLE COUNTY
November 11, 2006
Franz Stone V, Aspen Digging
0075 Sopris Ave.
Carbondale, CO 81623
RAYMOND P. MERRY, REHS
Director
RE: Issuance of Individual Sewage Disposal System (ISDS) Permit #2574A-06. Tax Parcel
#218927201004; Property Location: 777 Buck Point Drive, Carbondale, CO
Dear Franz,
Please find enclosed ISDS alteration permit, number 2574A-06 to conduct the construction
exactly as indicated on the permit. It remains valid for 120 days or for the duration of a current
building permit. The enclosed copy of the permit must be posted at the installation site. Any
changes in plans or specifications must be pre -approved by this department.
It is important to pay close attention to the special conditions which may have been included to
address site specific issues. All components of the system must be exposed for our
inspection.
Please remember our annual time frame for ISDS installations (unless otherwise specifically
approved by this department) in that permits issued on or before November 15 must be
installed prior to December 1. If unfavorable conditions prevail between the installation
and the final inspection (such as snow) special precautions must be taken to protect the
components from the elements to allow adequate inspections.
Please keep this office informed regarding the progress of your installation so we can provide
responsive customer service when scheduling your final inspection. Occupancy of the new
dwelling cannot be issued without the septic system being finally inspected.
If you have any questions, please feel free to contact us at (970) 328-8755.
Sincerely,
i
Terri Vroman, Administrative Technician IV
Enclosures: ISDS Permit #2574A-06
500 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179
4 - I
,,4rvIt-vW
R 'JECT 177 POIN7- DR,
PROJECT Pat)4b I
k)
project description A h -at,,,vc) _J4 W
date
task/action
follow-up
start
date
completion
date
4�
cz
ILL
M
M
PROJECT CONTACTS
name
phone/fox
e-mail
LLOL P, zjtkS F
'�70 — _7_M`-- el,:76)q
it
c't 70
,,7kfl ,777
documents enclosed
notes
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway o Eagle, Colorado 81631
Telephone: 328-8755
YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1 4 7 9
Please call for final inspection before covering any portion of installed system.
OWNER: David & Laura Struempler PHONE: 927-4171
MAILINGADDRESS: P. 0. Box 323 cty:Basalt state: CO Zip:81621
APPLICANT: David & Laura Struempler PHONE: 927-4171
SYSTEMLOCATION: 0777 Buck Point Dr. , Carbondale TAX PARCEL NUMBER: 2189-272-01-004
LICENSED INSTALLER: Elsworth Construction Co., Garry Elsworth ucENSENO: 60-95
DESIGN ENGINEER OF SYSTEM:
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
1000 GALLON SEPTIC TANK
ABSORPTION AREA REQUIREMENTS:
SQUARE FEET OF SEEPAGE BED 968 SQUARE FEET OF TRENCH BOTTOM.
SPECIAL REQUIREMENTS: Install 27 infiltrators in serially distributed trenches with 6ft.sidewall
to sidewall,as per requested by owner. Rake trench sidewalls and bottom. Do not install or
backfill in the rain. Call the County for final inspection.
L
ENVIRONMENTAL HEALTH APPROVAL: DATE: August 8, 1995
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT
TO AUTHORITY GRANTED IN 25. 10. 104. 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION
TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A
REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED.
FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED
PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 968 SQUAREFEET, via 27 infiltrators
INSTALLED SEPTIC TANK: 1000 GALLON 1580 N DEGREES 4016" FEETFROM the cleanout next to the house.
SEPTIC TANK ACCESS TO WITHIN S" OF FINAL GRADE AND
PROPER MATERIAL AND ASSEMBLY X YES NO
COMPLIANCE WITH COUNTY/ STATE REQUIREMENTS: X YES NO
ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED.
COMMENTS:
7�
ENVIRONMENTAL HEALTH APPROVAL: f <z a DATE: C j
ENVIRONMENTAL HEALTH APPROVAL: DATE:
(RE -INSPECTION IF NECESSARY)
RETAIN WITH RECEIPT RECORDS
APPLICANT / AGENT:
161TINi1qI4s1
PERMIT FEE PERCOLATION TEST FEE _ RECEIPT # CHECK #
Incomplete Applications Will NOT Be Accepted
(Site Plan MUST be attached)
ISDS Permit # /�
Building Permit #
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE.- EAGLE COUNTY
P. 0. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (Basalt)
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST E $2(00.00*,
* MAKE ALL REMITTANCE PAYABLE';TO: "EAGLE COUNTY TREASURER"
PROPERTY OWNER:
MAILING ADDRESS: _I -In Ct N;Co Z ) � 2-- 1 PHONE: q2-'"LI /T i
APPLICANT/CONTACT PERSON: 1- ( 11' °cst PHONE:
LICENSED SYSTEMS CONTRACTOR: PHONE:
COMPANY/DBA: toy -S � 1`l� � ADDRESS:
******************************** ***************************** ****** *****
PERMIT APPLICATION IS FOR: (A NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description: )-oi
Tax Parcel Number: c lq' a:7+a- j— o!:: j Lot Size: 3 9 CKcr S-
Physical Address:
BUILDING TYPE: (Check applicable category)
Residential/Single Family Number of Bedrooms
( ) Residential/Multi-Family* Number of Bedrooms
( ) Commercial/Industrial* Type
TYPE OF WATER SUPPLY: (Check applicable category)
Well ( ) Spring ( ) Surface
( ) Public Name of Supplier:
*These systems require design_by a Registered Professional Engineer
SIGNATURE:t C',
************************* *********
AMOUNT PAID: RECEIPT
CHECK #:
Date 4
j - DATE:
:7 7 P CASHIER:
t
Community Development Department
'(970) 328-8730
Fax: (970) 32:,3-7185
TDD: (970 _8-8797
EAGLE COUNTY, COLORADO
September 22, 1995
David and Laura Struempler
P.O. Box 323.
Basalt, CO 81621
Eagle County Building
1).0. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit No. 1479-95 Parcel #2189-272-01-004.
Property located at: 077.7 Buck Point Dr., Carbondale, CO.
Dear Mr. and Mrs. Struempler,
This letter is to inform you that the above referenced ISDS
Permit has been inspected and finalized. Enclosed is a copy to
retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also
enclosed is a brochure regarding the care of your septic system.
Be aware that later changes to your building may require
appropriate alterations of your septic system.
If you have any questions regarding this permit, please contact
the Eagle County Environmental Health Division at 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
ENCL: Information Brochure
Final ISDS Permit
enclosures
COMMUNITY DEVELOPMENT
DEPARTMENT
(303) 328-8730
Date:
I ••
August 9, 1995
Elsworth Construction Co.
Environmental Health Division
725 CHAMBERS AVE.
P.O. BOX 179
EAGLE. COLORADO 81631
FAX (303) 328-7207
RE: Issuance of Individual Sewage Disposal System
Permit No. 1479-95 Tax Parcel #2189-272-01-004
Property Location: 0777 Buck Point Dr.,
Carbondale, Co. Struempler residence.
Enclosed is your ISDS Permit No. 1479-95.It is valid for 120
days. The enclosed copy of the permit must be posted at the
installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved. Please call
our office well in advance for the final inspection.
systems designed by a Registered Professional Engineer must be
certified by the Engineer indicating that the system was
installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Engineer as builts must
be submitted for permit to be finalized and C.O. issued.
Permit specifications are minimum requirements only, and should
be brought to the property owner's attention.
This permit does not indicate conformance with other Eagle County
requirements.
If you have any questions, please feel free to contact the
Environmental Health Division at 328-8755.
cc: files
I '-) u J F L H M I r
PERCOLATION TEST
EAGLE COUNTY ENVIRONMENTAL HEALTH DEPT.
OWNER:
LEGAL DESCRIPTION:
MAILING ADDRESS;
TYPE OF DWELLING:
I
NUMBER OF BEDROOMS
TEST HOLES PRE-SOAKED: YES NO
T I, 'S
VT'
NMI
owl
MINI
MINI
Time to drop last inch q0
PERC RATE: MINIMUM SEPTIC TANK SIZE: o
n
MINIMUM LEACH FIELD SIZE: C7
COMMENTS: � , V) A
Coe&
PER Y: COS � ('Of -
DATE:
Envi'r'onmental Health officer
fo
rev. 6/90ks
ISDS Final Inspection
Completeness Form
V1/-rank is MC) aal. Tank Material
Tank is located ft. and degrees from—
(p4eL.a . �.dak)
Tan is located ft. and degrees from-
----�Tank set level.
--`_Tank lids within 8" of finished grade.
Size of field ft2 units lineal ft.
Technology
Cleanout is installed in between tank and house(+ 1/100ft).
There is a IT'l.that goes down 14 inches in the inlet and
outlet of the tank.
Inlet and outlet is sealed with tar tape, rubber gasket
etc.
L.,4ank has two compartments with the larger compartment
closest to the house.
Measure distance and relati,-,re dixelc�4on toltie1jV
V Depth of field' . ft.
Soil interface raked.
Inspection portals at the end of each trench.
Proper distance to setbacks.
Other V-1,trj,Cf i
t ram'
Inspection meets requirements.
Copy form to installer's file if recommendations for
improvement were suggested.
ACTION TAKEN:
Setbacks
Well Potable House Property Lake Dry Tank Drain
Water Lines line Stream Gulch
Field 100 25 20 10 50 25 10 10
Tank 50 10 5 10 50 10 10
Cr j
Eg
11 1