Loading...
HomeMy WebLinkAbout194 Ronce Ln - 239133402004 - OWTS-6-14-10824DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eaalecounty.us EAGLE COUNTY P.O. Box 179 500 Broadway Eagle, CO 81631 www.eaglecounty.us PERMIT APPLICATION FOR ONSITE WASTEWATER TREATMENT SYSTEM OWTS PERMIT #OWTS IP ILG BUILDING PERMIT # INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED) FEE SCHEDULE APPLICATION FEE $800.00 MAJOR REPAIR FEE $800.00 MINOR REPAIR FEE $400.00 This fee includes the OWTS Permit, Site Evaluation (Percolation Test, or Soil Profile Observation) and Final Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction site visit or consultation is needed. The re -inspection fee is $135.00 Make all remittance payable to: Eagle County Treasurer. Property Owner: T�Ir \" L ��-v.aw. hone: 110- 9 4 � - 1 ` f14 e� . Mailing Address: 9 Qz'n�- �--c-,^c- $��23 email 2-���C�t�� vra .covv% Registered Professional Engineer: .SpXISt- Phone: 910-1-04-OSI i Applicant or Contact Person: O"ne-c- Phone: Licensed Systems Contractor: I �� License # Company / DBA: Phone: Mailing Address: email Permit Application is for: New Installation V" Alteration Location of Proposed Onsite Wastewater Treatment System: Legal Description: Tax Parcel Number: %7- O Assessor's Link: www.easlecounty.us/patie! Physical Address: Building Type: 1'�Ioq/ Residential / Single Family Residential / Multi Family Repair Lot Size: 4- • (o S G Number of Bedrooms: Number of Bedrooms: Commercial / Industrial* Type of Use: *These systems require design my a Registered Professional Engineer Type of Water Supply: Private Well If Public Name of Supplier: Applicant Signature: ************************ Spring ,____ Surface Public q—. ********************************************************* Office Use Only p-a -- Amount Paid: 40 Receipt #: Check #: ��, Date:&/ May 26, 2016 Mr John Putnam RE: Final approval of septic permit OWTS-6-14-10824; Tax parcel #239133402004; Property location: 194 Ronce Lane, El Jebel area Mr. Putnam: This letter is to inform you that the above-referenced septic permit was not sent to a Licensed Installer as one was not listed so in effect the septic system was installed without a permit . This permit was approved and sized for a total capacity for 3 bedrooms and should work correctly if the Engineer design was followed. Additional information about the maintenance your septic system needs can be accessed through web site links provided on the Environmental Health Department’s home page at http://www.eaglecounty.us/envHealth/ Be aware that changes in the use of your property or alterations of your building may require commensurate changes to, or relocation of, your septic system. Landscape features, trees with tap roots, irrigation systems and parking areas above the drain field can cause premature system failure. It is equally important that you notice and immediately repair dripping faucets and hissing toilets as this will certainly cause the system to fail. By following a few simple guidelines, like avoiding grease or other additives down the drain and making sure your septic tank is on a pumping schedule, your system has been designed to last for many years. If you have any questions regarding this information, please contact us at (970) 328-8755 and reference the OWTS septic permit number. Sincerely, Terri Vroman Administrative Technician IV cc: OWTS electronic permit folder Energov electronic file LKP Engineering – Project 07156 DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eaglecounty.us RAYMOND P. MERRY, REHS Director 6/1/2016 Eagle County Government Mail -Re: 20097.02 RE: Putnam Garage sewer service pipe Ray Merry <ray. merry@eaglecounty. us> EAGLE C_-:7) NT'f Re: 20097.02 RE: Putnam Garage sewer service pipe Ray Merry <ray. merry@eaglecounty. us> Wed, Jun 1, 2016 at 12:11 PM To: John Putnam <72alfa51@gmail.com> Cc: #environment <environment@eaglecounty.us>, Vance Gabossi <Vance.Gabossi@eaglecounty.us>, Paul Rutledge <prutledge@sopriseng.com> John, I'm sending a quick reminder so the completion of your garage construction project goes smoothly (building permit RES 5-14-10758 and septic connection permit OWTS 6-14-10824). 1 noticed that your building permit is set to expire on the 18th of this month but as long as inspections are performed, can be extended as I understand it. Environmental Health is still waiting for you to select a licensed systems contractor so we can send them the OWTS permit to run the sewer line from the garage and connect it to the existing septic system as specified by Sopris Engineering in their design dated April 14, 2014. Once we issue the OWTS Permit, the licensed contractor can perform the work and Sopris Engineering can conduct the inspection to provide certification that the connection was done according to their plans. We will alert the building department that the garage bathroom has adequate sewage disposal once we receive certification from Sopris Engineering and be done with the Environmental Health part of your project. Thanks and please "reply all" to this email should you have any questions. On Thu, May 29, 2014 at 5:31 PM, John Putnam <72alfa51@gmail.com> wrote: Terri - Attached (I hope) you will find the drawing from Sopris Engineering showing the septic tie-in for my proposed addition. Please let me know if you do not receive and I will send hard copy with application. Thanks - John Putnam Raymond P. Merry, REHS Director of Environmental Health PO Box 179 Eagle, CO 81631 970.328.8757 ray. merry@eaglecounty. us AThanks for not printing electronic media hftps:Hmail.google.com/mail/ca/LV0/?ui=2&ik= 1141485fcl &view= pt&search=sent&msg= 1550d29fa873bb6e&sim 1=1550d29fa873bb6e 1/1 6/7/2016 Eagle County Government Mail -Re: 20097.02 RE: Putnam Garage sewer service pipe pawed M�r4Y, .�;li� EAGLE Ray Merry <ray. merry@eaglecounty. us> Re: 20097.02 RE: Putnam Garage sewer service pipe Paul Rutledge <prutledge@sopriseng.com> To: Ray Merry <ray.merry @eaglecounty.us> Cc: John Putnam <72alfa51@gmail.com> Hi Ray Tue, Jun 7, 2016 at 10:22 AM I do not know who did the installation. I was not informed of the construction schedule or contacted by the owner or excavator. I only discussed the proposed installation with the owner and the connection to the septic tank in relation to the proposed garage sewer pipe. My last correspondence regarding the selection of a contractor was in response to an email I forwarded to John from Terri dated May 11, 2015. 1 was told that a plumber has been selected but I was not contacted by the contractor during this period of the schedule or requested to come to the site. My initial inspection was performed prior to completion of the connection without the benefit of the owner or contractor being on site. A follow up email was sent by Terry on February, 20 2015 to which I have no record of response. Another followup email was sent by Terri on May 15. 2016. 1 spoke with John and performed a recent inspection of the completed work. My followup inspection occured just prior to your Email dated June 1. As we have discussed before, OWTS plan continue to evolve with additional notes to cover issues that arise from individual projects. My more recent notes regarding pre construction meetings, contacts for inspection and coordination with the Engineer and County should have been added to Revised/Updated OWTS plan dated April 14, 2014 to clarify procedures. Paul Rutledge Design Engineer Sopris Engineering 970 704 0311 ----- Original Message ----- From: "Ray Merry" <ray.merry@eaglecounty.us> To: "Paul Rutledge" <prutledge@sopriseng.com> Cc: "#environment" <environment@eaglecounty.us>, "Vance Gabossi" <Vance. Gabossi@eaglecounty. us>, "John Putnam" <72a1fa51@gmai1.com> Sent: Monday, June 6, 2016 12:46:02 PM Subject: Re: 20097.02 RE: Putnam Garage sewer service pipe Thanks, Paul. Do you know who did the installation without the OWTS permit, required by 43.4 (F.)(4.)? John wasn't sure except for mentioning "Colorado Western Excavation" he thought out of Rifle and the name "Guiterez". There is a Western Colorado Excavating, Inc. company out of Rifle but I'd like to be certain prior to corresponding with them. Thanks. On Fri, Jun 3, 2016 at 5:39 PM, Paul Rutledge <prutledge@sopriseng.com> wrote: > Hi John and Ray > Attached is the AB letter and revised AB Record Drawing. > Thank you hftps:Hmail.google.com/mail/ca/LV0/?ui=2&ik= 1141485fc1 &view= pt&search= i nbox&m sg=1552b9c2b3333944&si m 1=1552b9c2b3333944 1 /3 6/24/2016 Eagle County Government Mail - Re: 20097.02 RE: Putnam Garage sewer service pipe P.- hYGcxS1c Ray Merry <ray.merry@eaglecounty.us> EAGLE COUNT Re: 20097.02 RE: Putnam Garage sewer service pipe John Putnam <72alfa51@gmail.com> Thu, Jun 23, 2016 at 6:21 PM To: Ray Merry <ray. merry@eaglecounty. us> Cc: Paul Rutledge <prutledge@sopriseng.com>, #environment <environment@eaglecounty.us>, Vance Gabossi <Vance.Gabossi@eaglecounty.us> Ray - My apologies for the late response as I have been on the road on on a boat. Yes, Western CO Ex was the company and Jimmy Guitineres (sp) is the owner. Let me know if there anything else I can get for you. Thanks for your help and understanding of my efforts to GC my project. John On Mon, Jun 6, 2016 at 2:46 PM, Ray Merry <ray.merry@eaglecounty.us> wrote: Thanks, Paul. Do you know who did the installation without the OWTS permit, required by 43.4 (F.)(4.)? John wasn't sure except for mentioning "Colorado Western Excavation" he thought out of Rifle and the name "Guiterez". There is a Western Colorado Excavating, Inc. company out of Rifle but I'd like to be certain prior to corresponding with them. Thanks. On Fri, Jun 3, 2016 at 5:39 PM, Paul Rutledge <prutledge@sopriseng.com> wrote: Hi John and Ray Attached is the AB letter and revised AB Record Drawing. Thank you Paul Rutledge Design Engineer Sopris Engineering 970 704 0311 ----- Original Message ----- From: "Ray Merry" <ray.merry@eaglecounty.us> To: "John Putnam" <72alfa51@gmail.com> Cc: "#environment" <environment@eaglecounty.us>, "Vance Gabossi" <Vance.Gabossi @eaglecounty.us>, "Paul Rutledge" <prutledge@sopriseng.com> Sent: Wednesday, June 1, 2016 12:11:42 PM Subject: Re: 20097.02 RE: Putnam Garage sewer service pipe John, I'm sending a quick reminder so the completion of your garage construction project goes smoothly (building permit RES 5-14-10758 and septic connection permit OWTS 6-14-10824). 1 noticed that your building permit is set to expire on the 18th of this month but as long as inspections are performed, can be extended as I understand it. Environmental Health is still waiting for you to select a licensed systems contractor <http://www.eaglecounty.us/EnvHealth/Documents/Septic/Licensed_ Installers_Cleaners/> so we can send them the OWTS permit to run the sewer line from the garage and connect it to the existing septic system as specified by Sopris Engineering in their design dated April 14, 2014. Once we issue the OWTS https://m ai l.googl e.com /m ai I/ca/u/0/?ui=2&i k=1141485fc 1 &view= pt&search= i nbox&m sg=1557fc8b234faa29&si m l=1557fc8b234faa29 1 /2 6/24/2016 Eagle County Government Mail -Re: 20097.02 RE: Putnam Garage sewer service pipe Permit, the licensed contractor can perform the work and Sopris Engineering can conduct the inspection to provide certification that the connection was done according to their plans. We will alert the building department that the garage bathroom has adequate sewage disposal once we receive certification from Sopris Engineering and be done with the Environmental Health part of your project. Thanks and please "reply all" to this email should you have any questions. On Thu, May 29, 2014 at 5:31 PM, John Putnam <72alfa51@gmail.com> wrote > Terri- > Attached (I hope) you will find the drawing from Sopris Engineering > showing the septic tie-in for my proposed addition. Please let me know if > you do not receive and I will send hard copy with application. > Thanks- • John Putnam Raymond P. Merry, REHS Director of Environmental Health PO Box 179 Eagle, CO 81631 970.328.8757 ray. merry. @eaglecounty. us P *Thanks for not printing electronic media* Raymond P. Merry, REHS Director of Environmental Health PO Box 179 Eagle, CO 81631 970.328.8757 ray.merry@eaglecounty. us `'� Thanks for not printing electronic media hftps:Hm ai I.googl e.com /m ai I/ca/u/0/?ui=2&i k=1141485fc 1 &view= pt&search= i nbox&m sg=1557fc8b234faa29&si m 1=1557fc8b234faa29 2/2 6/7/2016 Eagle County Government Mail -Re: 20097.02 RE: Putnam Garage sewer service pipe > Paul Rutledge > Design Engineer > Sopris Engineering > 970 704 0311 > ----- Original Message ----- > From: "Ray Merry" <ray.merry@eaglecounty.us> > To: "John Putnam" <72alfa51@gmail.com> > Cc: "#environment" <environment@eaglecounty.us>, "Vance Gabossi" < > Vance. Gabossi@eaglecounty.us>, "Paul Rutledge" <prutledge@sopriseng.com> > Sent: Wednesday, June 1, 2016 12:11:42 PM > Subject: Re: 20097.02 RE: Putnam Garage sewer service pipe > John, > I'm sending a quick reminder so the completion of your garage construction > project goes smoothly (building permit RES 5-14-10758 and septic connection > permit OWTS 6-14-10824). 1 noticed that your building permit is set to > expire on the 18th of this month but as long as inspections are performed, > can be extended as I understand it. > Environmental Health is still waiting for you to select a licensed systems > contractor > http://www.eaglecounty.us/EnvHealth/Documents/Septic/Licensed_Installers_Cleaners/ > so we can send them the OWTS permit to run the sewer line from the garage > and connect it to the existing septic system as specified by Sopris > Engineering in their design dated April 14, 2014. Once we issue the OWTS > Permit, the licensed contractor can perform the work and Sopris Engineering > can conduct the inspection to provide certification that the connection was > done according to their plans. We will alert the building department that > the garage bathroom has adequate sewage disposal once we receive > certification from Sopris Engineering and be done with the Environmental > Health part of your project. > Thanks and please "reply all" to this email should you have any questions. > On Thu, May 29, 2014 at 5:31 PM, John Putnam <72alfa51@gmail.com> wrote: > > Terri- * > Attached (I hope) you will find the drawing from Sopris Engineering > > showing the septic tie-in for my proposed addition. Please let me know if > > you do not receive and I will send hard copy with application. > > Thanks- * > John Putnam > Raymond P. Merry, REHS > Director of Environmental Health > PO Box 179 > Eagle, CO 81631 > 970.328.8757 > ray.merry@eaglecounty.us hftps://mail.google.com/mail/ca/LV0/?ui=2&ik= 1141485fc1 &view= pt&search= i nbox&m sg=1552b9c2b3333944&si m I=1552b9c2b3333944 2/3 6/7/2016 Eagle County Government Mail -Re: 20097.02 RE: Putnam Garage sewer service pipe > P *Thanks for not printing electronic media* Raymond P. Merry, REHS Director of Environmental Health PO Box 179 Eagle, CO 81631 970.328.8757 ray. merry@eaglecounty. us P *Thanks for not printing electronic media* hftps:Hmail.google.com/mail/ca/LV0/?ui=2&ik= 1141485fc1 &view= pt&search= i nbox&m sg=1552b9c2b3333944&si m I=1552b9c2b3333944 3/3 H� tech November 29, 2000 Hepworth-Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Fax: 970.945-8454 hpgeo@hpgeotech.com John and Robin Wood 521 Canyon View Drive Golden, Colorado 80403 Job No. 100 569 Subject: Additional Shallow Percolation Testing, Proposed Septic Disposal System, Lot 4, Gabossi Subdivision, 194 Ronce Lane, Eagle County, Colorado. Dear Mr. and Mrs. Wood: As requested by Paul Rutledge with Sopris Engineering, a representative of Hepworth- Pawlak Geotechnical, Inc. conducted additional shallow percolation testing at the subject site to evaluate the feasibility of an infiltration septic disposal system. The results of our work are presented in this report. We previously conducted a subsoil study and percolation test. and presented our findings in a report dated August 9, 2000, Job No. 100 569. Additional percolation testing at depths between 58 and 64 inches was conducted in this area and the results presented in a report dated November 6, 2000, Job No. 100 569. Three shallow backhoe pits had been excavated at the locations shown on Fig. 1. Percolation test holes (P 7, P-8 and P-9) were hand dug in the bottom of the backhoe pits and soaked one day prior to testing. The holes were covered with rigid foam insulation to protect against freezing overnight. The soils exposed in the percolation holes are similar to those exposed in the profile pit previously excavated in this area and consist of about 1 foot of topsoil overlying relatively dense slightly silty sandy gravel with cobbles and occasional small boulders to the profile pit depth of 1Otl2 feet. Groundwater was not observed in the profile pit and the soils were slightly moist to moist. Percolation tests were performed on November 22, 2000 by a representative of. Hepworth-Pawlak Geotechnical, Inc. The ground temperature A the time of the testing was about 40' to 43 ° F. The percolation test results are presented on Table I. The percolation test results indicate an infiltration rate of between about 12 and 20 minutes per inch with an average of 15 minutes per inch. If there are any questions or if we may be of further assistance, please let us know.. Sincerely, HEPWORTH - PAWLAK GEOTECHNICAL, INC. Jordy Z. Adamson, Jr., P.E. Rev. by: DEH JZA/ksw attachments cc: Sopris Engineering - Attn: Paul Rutledge LOT 4 PROFILE P 6 PIT 0 .P 5 P7 Q-P4 P 8 A I P 9 EXISTING IRRIGATION \ DITCH AP 1 AP EXISTING A P 3 SHED � I Gj 1 E/ BUILDINGI� PIT 3, SITE a / PI' PIT 1_— lop OF STEEP SLOPE APPROXIMATE SCALE 1" = 100' BENCH MARK: TOP OF WELL CASING, ELEV. = 100.0% ASSUMED. ROAR/NG FORK RIbER LEGEND: Q ADDITIONAL PERCOLATION TESTS FOR THIS STUDY. A, PERCOLATION TESTS FROM PREVIOUS STUDY. ® PROFILE PITS FROM PREVIOUS STUDY. I HEPWORTH — PAWLAK LOCATION OF EXPLORATORY PITS ! FI 1 100 569 GEOTECHNICAL, INC.. AND PERCOLATION TEST HOLES. f 9' 0 P HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE I PERCOLATION TEST RESULTS JOB NO. 100 569 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF . INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN.IINCH) P-7 36' 10 water added " 6'/a 5'/: 1 . 13 5 % 4 • 4 a/4 4 a/4 7 6 '/x /a 6 T/x 5 5 '/4 5 1/4. 5 4 '/4 - '/4 P-8 - 3o " " 10 water added water added water added 5 %a 3 %a 2 12 5 4 1 4 3 %4 5 '/: 4 '/: 1 4 '/a 5'h 4%a 1 4 ''A 3 a/4 a/c 3 %4 3 a/4 P-9 30 10 water added 5 'h 5 /_ 20 5 4 %x /a 4 4 /a ' 4 3 '/a T/a 5 '/4 5 /4 5 4 f4 '/a 4 'h 4 /_ 4 3 '/a '/a Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on November 21, 2000. The holes were covered with rigid foam insulation to protect against freezing overnight. Percolation tests were conducted on November 22, 2000. The average percolation rates were based on the last three readings of each test. Hepworth-Pawlak GeotechnicaI, Inc. 5020 County Road 154 Glenwood Springs, Colorado 31601 Phone: 970-945-7988 Fax:970.945.8454 hpgeo@hpgeotech.com August 9, 2000 John and Robin Wood 521 Canyon View Drive Golden, Colorado 80403 Job No. 100 569 Subject: Subsoil Study for Foundation Design and Percolation Test, Proposed Residence, Lot 4, Gabossi Subdivision, 194 Ronce Lane, Eagle County, Colorado Dear Mr. and Mrs. Wood: As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and percolation test for foundation and septic disposal designs at the subject site. The study was conducted in accordance with our agreement for geotechnicai engineering services to you dated July 11, 2000. The data obtained and our recommendations based on the proposed construction and subsurface conditions encountered are presented in this report. Proposed Construction: The proposed residence will be a one and two story wood frame structure located on the site as shown on Fig. 1. Ground floors will be slab -on - grade. Cut depths are expected to range between about 2 to 4 feet. Foundation loadings for this type of construction are assumed to be relatively light and typical of the proposed type bf construction. The septic disposal system is proposed to be located just north of the proposed residence. If building conditions or foundation loadings are significantly different from those described above, we should be notified to re-evaluate the recommendations presented in this report. Site Conditions: The lot consists of a relatively flat irrigated field between Ronce Lane on the north and the Roaring Fork River on the south. The building area is located at the southwest end of the field next to the top of a very steep slope down to the river. The slope is about 30 feet high and has a grade of about 13/4 horizontal to 1 vertical (60%). The slope appeared to be relatively stable. The'adjacent lots are developed with residences next to the steep down slope. John and Robin Wood August 9, 2000 Page 2 Subsurface Conditions: The subsurface conditions at the site were evaluated by excavating three exploratory pits in the building and septic disposal areas at the approximate locations shown on Fig. 1. The logs of the pits are presented on Fig. 2. The subsoils encountered, below about 1/2 foot of topsoil, consist of relatively dense, slightly silty sandy gravel and cobbles with boulders. The subsoils are river terrace deposits. Results of a gradation analysis performed on a sample of sandy gravel (minus 5 inch fraction) obtained from the site are presented on Fig. 3. No free water was observed in the pits at the time of excavation and the soils were moist. FCiInuaiCn RSCCmraieAdatiCuS: COuSldeImg the subsoil cvnditivnS enCOnntered m the exploratory pits and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 3,000 psf for support of the proposed residence. Footings should be set back at least 10 feet horizontally from the face of the steep down slope for stability considerations. The setback should be field verified at the time of construction. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils encountered at the foundation bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural soils. Voids created by boulder removal should be backfilled with compacted gravel or with concrete. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings_ at least 42 driches below the exterior grade is typically used in this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid uait.weight of at least 40 pcf for the on -site soil as backfill, excluding vegetation, topsoil and rock larger than about 6 inches. Floor Slabs: The natural on -site soils, exclusive of topsoil, are suitable to support lightly loaded slab -on -grade construction. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints Jshould be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on H-P GEOTECH John and Robin Wood August 9, 2000. Page 3 experience and the intended slab use. A thin layer of free -draining gravel may be placed beneath interior slabs to act as a leveling course. This material should consist of minus 2 inch aggregate with less than 50% passing the No. 4 sieve and less than 2% passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95 % of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on -site gravel soils devoid of vegetation, topsoil and oversized rock. Underdrain System: Although free water was not encountered during our exploration, it has been our experience in the area that local perched groundwater can develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can create a perched condition. We recommend below -grade construction, such . as retaining walls and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. Shallow crawlspace should not need a foundation drain provided backfill is properly placed and compacted and the surface has a positive slope away from the building. The drains should consist of drainpipe placed in the bottom of the wall backfill surrounded above the invert level with free -draining granular material. The drain should be placed at each level of excavation and at least I foot below lowest adjacent finish grade and sloped at a minimum 1 % to a suitable gravity outlet. Free -draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 50 % passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 1'/2 feet deep. Surface Drainage: The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95 % of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard JProctor density in landscape areas. Free -draining wall backfill should be capped with about 2 feet of the on -site, finer graded soils to reduce H-P GEOTECH John and Robin Wood l�August 9, 2000 J Page 4 surface water infiltration. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 6 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in pavement and walkway areas. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. Surface water should not be concentrated and directed on to the steep down slope without adequate erosion protection. Percolation Testing: Percolation tests were conducted at the locations shown on Fig. 1 to evaluate the feasibility of an infiltration septic disposal system at the site. The test holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The soils exposed in the percolation holes are similar to those exposed in the exploratory pits 13 shown on Fig. 2 and below the topsoil consist of slightly silty sandy gravel, cobbles and J boulders. The percolation test results are presented in Table 1. Based on the subsurface conditions encountered and the percolation test results, the tested area should be suitable for a conventional infiltration septic disposal system. If the disposal area is located closer than 70 feet from the top of the steep down slope, we should be contacted for review of potential slope stability considerations. Limitations: This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either expressed or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Fig. 1, the proposed type of construction and our experience in the area. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits and variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear different from those described in this report, we should be notified at once so re-evaluation of the recommendations may be made. H-P GEOTECH John and Robin Wood ` J August 9, 2000 Page 5 This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on -site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engineer. If you have any questions or if we may be of farther assistance, please let us imow. Sincerely, HEPWORTH - PAWLAK GEOTECHNICAL, INC. Steven L. Pawlak, P.E. SLP/ksm attachments cc: Meldor Construction - Attn: Norm Bacheldor J H-P GEOTECH PIT 1 PIT 2 PIT 3 ELEV= 97,2' ELEV.=97.6' ELEV.=97.3' 0 0 b b y ! 5 aae os >°- 5 I -200=3 oa o 10 10 LEGEND: ® TOPSOIL; organic sandy silt, slightly moist, dark brown. Q ' GRAVEL, COBBLES AND BOULDERS (GM -GP); slightly siity, sandy, dense, moist, brown, rounded rocks -.i Disturbed bulk sample. -'COTES: 1. Exploratory, pits were excavated on August 2, 2000 with a backhoe. 2. Locations, of exploratory pits were measured approximately by pacing from features on the site plan provided. 3. Elevations of exploratory pits were measured by hand level and refer to the Bench Mark shown on Figure 1. 4. The exploratory pit locations and .elevations should be considered accurate only to the degree implied by the, method used. S. The lines between materials shown an the exploratory pit logs represent the approximate boundaries between material types and transitions may be gradual. 6. No free• water was encountered in the pits at the time of excavating. Fluctuations in water level may occur with time. 7. Laboratory Testing Results: }4 = Percent retained on No. 4 sieve -200 = Percent passing No. 200 sieve 100 569 HEPWORTH - PAWLAK LOGS OF EXPLORATORY PITS Fig: I 2 j GEOTECHNICAL, INC. HEPWORTH-PAWLAK GEOTECHNICAL, INC. Illir-iil»i PERCOLATION TEST RESULTS JOB NO. 100 569 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES)- DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MINJINCH) P-1 50 15 refill refill 6 36 4 V4 1 '/4 - S 4% 3 1'/4 3 6'/4 1 % 6 A 4 2 1/4 7 '1A 6 1 '/2 6 3 3/4 2 '/4 P-2 50 15 ' refill refill 4 1 A. 2 10 6 %: 5 '/2 1 5A 2 3%: 6 '% 5 1 '% 5 3 %: 1 Y. P-3 ' 49 15 refill refill refill 5 3 2 7 '/4 4 3 '/4 4 2 Y, 1 %: 6 % 4 %4 2.'/s 6 '% 5 1 '/4 Note: Test holes were hand dug in bottom of backhoe pits and soaked on August 2, 2000. Percolation test were conducted on August 3, 2000. The percolation rate is the average of the last two readings of each test. J GP:.,,. b1tech HEPWORTH-PAWLAK GEOTECHNICAL October 28, 2004 John Wood 194 Ronce Lane Hepworth-Pawlak Geocechnical, Inc. 5020 Councy Road 154 Glenwood Springs, Colorado 81601 Plione: 970-945-7988 Fax: 970-945.8454 email: hpgeoehpgeorech.com Carbondale, Colorado 81623 Job No. 100 569 Subject: Observation of Excavation, Proposed Office/Study Addition,194 Ronce Lane, West of El Jebel, Eagle County, Colorado Dear Mr. Wood: As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. observed the excavation at the subject site on October 28, 2004 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. The services were performed in accordance with our agreement for professional engineering services to John Wood, dated October 28, 2004. We previously performed a subsoil study for the existing residence ^ dated August 9, 2000 , Job No. 100 569. JThe proposed addition will consist of a single story of wood frame construction approximately 16 feet by 16 feet in plan size attached to the southwest comer of the existing residence. Ground floor will be slab -on -grade. Spread footings designed for an allowable bearing pressure of 3,000 psf will support the addition. At the time of our visit to the site, the foundation excavation consisted of a perimeter trench cut in one level from 3% to 4 feet below the adjacent ground surface. The soils exposed in the bottom of the excavation consisted of slightly silty sandy gravel. The bottom of the excavation appeared to have been compacted. The existing footing is exposed along the east side of the excavation where the new footing will attach to the building. Up to 2 feet of silt and sand soils below 1 foot of on -site granular fill remained in the existing unexcavated portion of the proposed floor slab. No free water was encountered in the excavation and the soils were slightly moist to moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 3,000 psf should be adequate for support of the proposed addition. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. The bearing soils should be protected against frost and concrete should not be placed on frozen soils. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection_ Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 42 feet. The fine-grained soils remaining in the proposed slab area tend to compress and there could be some post -construction slab settlement, especially if the subgrade soils become wet. A positive way to limit slab Parker 303-841-7119 0 Colorado Springs 719-633-5562 • Silverthome 970-468.1989 John Wood October 28, 2004 Page 2 settlement would be to remove the fill and fine-grained soils to expose the underlying natural dense gravel and re-establish subgrade level with a suitable granular material such as road base. Structural fill placed within floor slab areas should be compacted to at least 95% of standard Proctor density at a moisture content near optimum. Baekfiil placed around the structure should be compacted and the surface graded to prevent ponding within at least 10 feet of the building. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. it is possible the data ob'uaned by subsurface exploration could change the recommendations contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, Jthen a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH—PAWLAK GEOTCHNICAL, INC. Trevor L. Knell, P.E. Reviewed by: Daniel E. Hardin, P.E. TLK/ksw Job No.100 569 MeCh 1 t - Getech November 6, 2000 John and Robin Wood Hepworth-Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone:970-945-7988 Fax: 970-945-8454 hpgeo@hpgeotech.com 521 Canyon View Drive Golden; Colorado 80403 Job No. 100 569 Subject: Additional Percolation Testing, Proposed Septic Disposal System, Lot 4, Gabossi Subdivision, 194 Ronce Lane, Eagle County, Colorado. . Dear Mr. and Mrs. Wood: As requested; a representative of Hepworth-Pawlak Geotechnical; Inc. conducted percolation testing at the subject site to evaluate the feasibility of an infiltration septic disposal system. The results of our work are presented in this report. We previously conducted a subsoil study and percolation test and presented our findings in a report dated August 9, 2000, Job No. 100 569. A profile pit and three shallow backhoe pits had been excavated at the locations shown on Fig. '1. Percolation test holes had been dug in the bottom of the backhoe pits and soaked by the excavator prior to our testing. The soils exposed in the percolation holes are similar to those exposed in the profile pit and consist of about 1 foot of topsoil overlying relatively dense slightly silty sandy gravel with cobbles and occasional small boulders to the profile pit depth of 101/2 feet. Groundwater was not observed in the profile pit and the soils were slightly moist to moist. Percolation tests were performed on November 3, 2000 by a representative of Hepworth-Pawlak Geotechnical, Inc. The percolation test results are presented on Table I. The percolation test results indicate an infiltration rate of between about 2 and 7 minutes per inch. Based on the subsurface conditions observed and the percolation test results, Eagle County may require that a civil engineer be engaged to design the septic disposal system. . If there are any questions or if we may be of further assistance, please let us know. Sincerely, HEPWORTH - PAWLAK GEOTECHNICAL, INC. Jordy Z. Adamson, Jr., P.E. J Rev. by: DEH JZAIksw . attachments LOT 4 P 6A I] PROFILE PIT P 4A 1 ( EXISTING IRRIGATION DITCH AP1 AP EXISTING A P 3 SHED Ep 0�/BUILDING1� PIT 3 ` SITE All / PI, PIT_1 ~ TOP OF STEEP SLOPE APPROXIMATE SCALE 1" = i00' BENCH MARK: TOP OF WELL CASING; ELEV. = 100.0', ASSUMED. ROAR/NG FOR/f R/YDR LEGEND: A ADDITIONAL PERCOLATION TESTS ® PERCOLATION TEST FROM PREVIOUS STUDY. HEPWORTH - PALOCATION OF I 100 569 ( GEOTECHNICAL, NC. AND PERCO ATIONLORATORY TEST HOLESS I F19' 1 I HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE I PERCOLATION TEST RESULTS JOB NO. 100 569 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN.ANCH) P-4 .60 1 5 % 5 '/4 2 5 % 4 3/4 4 3/4 4 '/z Y4 4 '/z 4 '/2 4 3 '/2 /: 3 '% 3 '/2 3 2 '/a './a 2 '/. 2 /: P-5 ' 64 5 9 7 2 7 7 6 1 6 5 '/4 '/4 5 % 4 T/x 3/4 4 % 3 3/4 3/4 3 '/4 3 Ya 3 2 '/4 3/4 2 '/4 1 'h % P-6 58 .. 1 5 % 5 '/4 '/x ' 2 5 Y4 5 '/4 5 4 % /4 4 0/4 4 Y4 '/2 4 '/4 3 °/4 Y: 3Y4 3A Y. 3 Y4 2 °/4 '/a 2 Ya 2 '/4 Ya Note: Percolation test holes were dug and soaked by others prior to our testing. Percolation tests were conducted on November 3, 2000. The average percolation rates were based on the last three readings of each test. . June 2, 2016 John Putnam Putnam Residence 194 Ronce Lane Carbondale CO 81623 "John Putnam" 72a1fa51(iDgmai1.com RE: Putnam Residence As -Built OWTS —Documentation and Design Capacity Site Location: Lot 4, Gabossi Subdivision, in Eagle County Colorado. SE Job No. 20097.02 , Building Permit RES 5-14-10758 & OWTS Permit 64440824 Dear John: Pursuant to Eagle County regulations, this letter and attached drawing provides docrunentation that the new utility sewer connection from your recently completed detached garage to the existing OWTS system is in compliance with the design dated April 14, 2014. Sopris Engineering has performed site visits to inspect, measure and document the as built conditions of the added components that connect to the previously installed septic tank. The as -built information and location of the new components and the previous OWTS components is delineated on the attached revised Record drawing. Also attached are construction photographs. The previously installed OWTS components were installed in accordance with the former Eagle County ISDS Regulations; the Sopris Engineering Report and the design drawings dated November 29, 2000. An As -built drawing and letter, dated January 18, 2001 was submitted to the County and previous property owners. At that time the proposed detached garage was not built, however the original building plans and associated OWTS design included the utility bathroom for the garage. Existine OWT5 Comnonents The existing system includes an absorption trench facility that was constructed utilizing serial distribution. The effluent is pumped to the inlet of the first serial absorption trench one to the existing sloping topography on site. Each trench was installed level and is complete with an inspection port. Adjacent trenches have a horizontal separation of approximately 6 feet. A separate 304nch diameter ribbed PVC pump basin chamber was installed near the proposed garage location that receives effluent from the double compartment, 1000- gallon concrete septic tank system previously installed with sanitary tees & effluent filter. The Pump basin was installed with an alternating dual pump assembly and provides adequate storage volume for effluent dosing and drain back. A two-way clean was installed between the house and the tank. The total as -built trench absorption area is 604 SF, utilizing 39 chambers and was sized per the previous design Regulations in effect at the time of construction. New OWTS Comnonents The new components recently completed include a new 4" SDR-26 PVC sewage pipe installed from the new garage utility bathroom to the previously installed septic tank. The pipe was installed with atwo-way clean out and was routed to the side inlet port for gravity discharge into the primary tank chamber. An inlet sanitary tee was installed that is accessible fi•om the primary chamber riser. The existing OWTS has adequate capacity to continue serving the residence with the utility bathroom. 502 Main Street •Suite A3 • Carbondale , CO 81623 (970) 704-0311 •Fax (970) 704-0313 SOPRIS ENGINEERING • Urp civil consultants John Putnam SE Job No. 20097.02 June 2, 2016 Page 2 In order to update the previous system documentation this OWTS As -Built conditions letter includes design capacity and soil information for current and future use. The soil conditions, former design capacity and associated capacity with respect to the current Regulation 43 design criteria are summarized below. Sub Surface Soil Conons A previous subsurface soil investigation was conducted by HP Geotech Inc, that reported the percolation test results dated August 9, 2000. The results of percolation tests indicated the average percolation rate of 15 minutes per inch. Additional Subsurface soil investigations and USDA soil texture method tests were performed by Sopris Engineering in May 2015. The soils in the area between the garage and septic tank were sampled and characterized by application of the USDA soil texture method analysis. The soils were tested to confirm the hydraulic loading rate for use in comparison of the existing system design with respect to Regulation 43. The soils appear to be consistent with the soils in the previously installed absorption system. The native soils sampled from 2-3 feet below the surface are characterized as a soil type 2 consisting of silt loam texture with granular structure. This soil has an effective loading rate for conventional soil treatment of 0.60 gal/S.F./day for a level 1 conventional treatment system. The equivalent percolation rate is approximately 16-25 minutes per inch. OWTS Design Criteria ner Former Regulation OWTS Design per Former County ISDS Regulation: Single family 3-bedroom home &fixture garage utility bathroom Design flow (Qd) = Q avg. flow (# of people x 75 gal/person/day x Treatment trenches Absorption/Infilhation Area Design: Average percolation rate of 15 minutes per inch. A= 675 *(15) %2 = 523 S.F. 5 1.5 Actual field size was calculated per previous Eagle County ISDS Regulations,Table 5: A = #bedrooms x 200 sf trench/bedroom = 3 x 200 = 600 sf Used previous standard infiltrator chambers: 15.5 sf interior surface per chamber. Therefore at: 600 sf = 38.7 chambers Installed 39 chambers 15.5 OWTS Design per Current Adopted County Regulation 43: Single family 3-bedroom home Design flow (Qd) = Q avg. flow (# of people x 75 gal/person/day = gal/day (design) 3 bedroom house equivalent @ 2 persons per bedroom Qavg = 3x2x75= 450 gal/day Total Design Flow is 450 gal/day Required septic tank volume is I000gallons John Putnam SE Job No. 20097.02 June 2, 2016 Page 3 OWTS Absorption Field Design per Current Adopted County Regulation 43: Number of previous standard infiltrator chambers (Regulation 43) (LTAR) for treatment level 1 is 0.60 gals/SF/day. L.F.1=1.0 Pump Dosed Trench (Table 10-2) L.F.2=0.7 Chambers in Trench (Table 10-3) Absorption area per old standard Infiltrator leaching chamber= 15.5 S.F. 450/0.6 x 0.9 x 0.7 = 473 sf /15.5 = 31 chambers. Installed 39 Chambers. Existing 39 chambers units = 39 chamber x 15.5 S.F./chamber = 605 S.F. Soil Treatment Unit (STU) Area. Assuming the new allowance for area per chamber based on 3' wide trench by chamber length (18.75) Then 18.75 S.F./chamber x 39 chambers = 731.25 S.F. Existing Capacity Q gpd = 731.25 S.F. x 0.6 g/sf/d / 0.9 / 0.7 = 696 gpd; 696 gpd 1150 galibedroom = 4.6 bedrooms. Summary The OWTS has the capacity to handle and treat sewage flows up to 696 gpd that would include 4 single family residential bedrooms with and additional 96 gpd capacity for other uses. The System has significant excess capacity above its current usage based on the existing 3-bedroom single family home. Continued Usaee and Maintenance The OWTS should be inspected on a regular basis and be properly maintained. The system and responsibility for repair and maintenance of the systems will remain with the Owner. The owner shall employ the services of qualified service providers to inspect the OWTS and perform any maintenance required that includes the cleaning of the septic tank effluent filter, dosing pump assembly and periodic pumping of the septic tank as necessary to ensure that the system is in good operating condition and performing as designed. In general, for a properly utilized system, septic tanks should be pumped and inspected every 2 - 4 years. The effluent filter should be cleaned every six months and at the time of pumping. Absorption fields should be maintained with suitable vegetative cover and kept five of root invasive plants. Positive surface drainage away from the absorption field should be maintained. If you have any question or need any additional information, please call. Sincerely, SOPRIS ENGINEERING, LLC Paul E. Rutledge Design Engir}gy�r'r�axtf 2ii09Y loot I ar► 1.4 >�) j'do r 6 jIF IF } - to 144 tofY OF Wl lea' l..1 -r m ' i i10 • .� t to IF For to 711 Foot F` • ¢ M1 � y , r to IF Flar 14 IF 14 IN LFF ! IF 4Foop IF It (j-!.'.3 # ,. IF. IF to F,q Ri Co Vic+W, LLL_ ,sarr}_-'- C.i F:. y. 4, jet -' ,.1 7 IF- or F,F&... 'thy ,t I' �. . 3 It For. I 43�. �. FA IF motor IF Ax %.. b age, y IF _ e w t �'!'a OPERATION AND MAINTENANCE GUIDE FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEMS Prepared by Sopris Engineering, L.L.C. April pril 6, 2000 A properly designed and utilized ISDS system should require minimal maintenance. In all cases the operation of the system should be automatic. Several factors influencing the need for maintenance include; actual wastewater flows into the system versus design flows, the volume of kitchen/domestic waste (excluding human waste and toilet paper), excessive household chemicals or other toxic liquids and the physical integrity of the system components. Maintenance of engineered and non engineered systems should include annual visual inspections of all structures, aocess/inspection ports and mechanical components if applicable. Larger dosing systems and large second homes may require periodic inspections with certain adjustments based on variable usage. ISDS Operation and Maintenance Septic Tanks It is recommended that the septic tank(s) should be inspected annually or if plumbing problems are -"� experienced. In general, for a properly designed system, septic tanks should be inspected and pumped 7c every 2 - 4 years. In addition to removal of the accumulated solids from the tank the service lines should be hydraulically cleaned. This procedure is usually performed by the septic pump service and is especially important in homes with'heavy kitchen use and/or plumbing problems. The scum layer should not exceed . a depth of 12" or exceed a depth of 3" above the bottom of the outlet device. The depth of solids (sludge) should not exceed 1/3 of the depth of the tank or a depth below the bottom of the outlet device of.15"-2.5" times the total liquid depth. The single most important aspect regarding maintenance of septic tank is the protection of the absorption area from failure due to suspended solids scouring the system. Measuring the scum and sludge layers is the only way to determine the need for pumping. Several methods can be used to determine if the above recommended depths have been exceeded from visual tape measurements to use of indicator sticks. Pumping the tank should be done by fast breaking up the scum layer and mixing the sludge layer with the liquid portion by alternately pumping liquid from the tank and re -injecting it into the bottom of the tank. This procedure should be repeated until only a small residual of sludge remains in the tank which is necessary for seeding purposes. Tanks should never be washed or disinfected after pumping Material removed from tanks should be disposed of per methods approved by local bealth jurisdictions. . Post pumping inspections are necessary to check inlet and outlet baffles and risers. Check for signs of damage, leaks in or out of tanks, proper sealing of access risers and closure of lids. Check the inlet service pipe and the outlet distribution pipe for accumulated debris to determine if cleaning is needed. Check the seals around the pipes at the inlet and outlet ports on the tank to insure they are watertight_ Repair any damage to insure the tank operates as designed. Appropriate safety and sanitary practices should always be followed while working with sewage systems. Check anchoring devices if applicable. Septic Tank Additives In general chemical, bacteriological or enzyme additives are not recommended or needed to maintain or improve septic tank efficiency. Available products have not been proven to enhance a systems performance and should not be used in an attempt to help breakdown solids to reduce the need for pumping. Some additives have proven to have adverse effects to the normal operation of the system. Dosine systems For systems with a dosing and/or distribution pump system it is recommended that the pumps, valves, siphons, tank, control floats, wires and any other applicable components be visually inspected annually for wear, damage, leaks, or other potential problems. Separate dosing tanks need to be checked for water tightness structural and plumbing integrity the same as for a septic tank. Check for evidence of sediments or scum layers which will indicate problems with the septic tank Check to see if the water level markings on the side of the tank are consistent Variability indicates that the distribution device, pumps, float switches and/or controls may not be operatingproperly. The dosing system should be checked for performance by observing it's dosing cycle, distribution pattern and calculating or monitoring its discharge volume. The current performance should be compared with previous observations and adjustments should be made to the controls if needed to maintain or improve compliance with the design. If a filter screen is used it should be cleaned as needed, annually and when the tank is pumped. Absorotion fields Absorption fields should be maintained with suitable cover and kept free of root invasive plants. positive surface drainage away from the absorption field should be maintained. The inspection ports should be observed to check for distribution and infUtration of effluent in the system. Check the surrounding ground for seepage, excessive wetness or erosion near the base of the filter mound or field. Avoid any frequent or heavy equipment or vehicular traffic over a field and immediately, evaluate and repair any damage to the system if an impact occurs. Check for any signs of subsidence. Maintain any barriers to prohibit livestock form entering the area Storm Draina To the maximum extent possible Storm water shall be directed away from absorption fields and prevented from entering system structures. Any breach in underground pipes or risers should be repaired as soon as possible. Alterations and additions to individual sites should be performed with respect to the existing ISDS system. Miscellaneous Guidelines and Precautions Avoid pumping tanks during high ground water months if tank is installed below the ground water table. Adequate anchoring on septic and dosing tanks is required on installations where groundwater is present. The absorption areas must be protected to prevent damage from vehicular or livestock traffic. Minimize the amount of water, oils, grease, household chemicals and solids discharging into the system. Garbage disposals are not recommend for use with ISDS systems or system size and maintenance schedules need to be increased by 30 to 50 percent. 502 Main Street • Suite A • Carbondale, CO 81623 • (970) 704.0311 • Fax (970) 704-0313 a Dx�-mCOp Now D. VI(� mm 2>1 V,.p -Z AO 0 �-mi J.�S a0 -Ir K-z OAo o c m a Ai z xOm;roC apt DmN y-I 09059 TOZS mZ N CDDD zm>y �CG Z rvrmF ��mDO �py�W jm C Opmp SS 0,v>wAOZ2D D2 m �o XK O� r>-zf9 caYm OA vvv mp zr K�1<xm po ovya o xmo ALCM �-,z ��vyx ~x Om vmmom ogm om -z1Om ->M,x SK <.i N� i 0 0 .ZmCy fx�lAm Z.Dy DOm1O O m OVImyZ rtl FomT- A- TZZID Iz"ao�n�. z�io omczim m� �'imoD>m Div x> o �m -IryO a' i�U1S O'I`rA mS mmo snim 2CmG) W �Om �; O o�gmK baOA T m m oz F '�y •��'yxA cm-i�vvoim mm ml"� Z mDZO m A vmz�om ZA Oy3 Mg S `N10u1e$�1�j'1�i'lcpfoul h4�/i/���' Z� Ems �� 0. ..isz Ee N M u�U -yI Ifn Z Z $� o uu F O iv v A y V n z � [� 0z [[i]f N yV 0 p a �O tC..),I AO mm vwiZ p m OOOO VJ � N mo oK tj o9 m� N0 a o i m 1 o pr5ya0AN Am mC➢yy>m yOm Om Om m 000~ DrZm mcqpimn mao-znpsD Zma p o� _v.am� `- F>y > o0 yylA.idoz= Ammppy aAma pm ZN0A ONnA zo�� A-O> N t*IA 0 A i, mA D ma -mnmmS cvx OOym r_ V OA D .z .Cw 0mpoz> Z'IOZ LIFO 4ZJNZ8 ON 'DAD tm� m T TtNnZmym m V1 y=NN rm220 Oy A[] 91 20rOOZ 'm (ZJ KNCm wlm, peml 1OOm m0 >x m o"m�o'm'' pm2 >cvm m mm z v� A>A>c, D�In <yno �m- r 'o"p �gm 0 mzm> o Cyo� o�v� mIA"Aa mw 82h by �x py2 r`i>n ?5Zm u�8cyim W ��z m K (m/1 DA -3y mON a' O'nZ �O~r 0 OCS m T A' 2> 820>0 S C a10.Zy1 ON 0m ZM�z-iW>OrO Zm6m-mmi O�<t�m m9F A3 Omoy oa my aO mm oc a,o m my zAy o Pm mzw o �om Nz > v ar < v myi Cmm <N WmN A ml 2 m y1 F �Y N G +DmiYU .�A P £8 o K� jm 26 > >59 fig_ 0 o Ap>c<Tzm y rp+��z roc ap ��Om�am 0�->1 uNiYpNO-� zi mOmAaTvzr- - nm � im6�o0 "Y' rnA z o>r- imA '!jz azy Am2 � p CAN Af ySD A9 pnr maz zos mm Nmy sm z >A-J tom moz m =10 z Amy zx az N w m nom A m yf�l O -Z T Z m N= On r mm �m v ym ma zZ AO a� r zz vm :5 A r z O N A FP.DI1 :,TIE `FF`(. TON StRI— :E ' FAR NO. :E=111 Rag. 23 2001 11:19AN '.. 29.5, IMPROVEMENT LOCATION CERTIFICATE- 194 PONCE LANE APPARENT / Z'.. '; GRAPHIC SCALE 50' A=SS xn " 1w em aum ESMT. PVC 66 1 inch - 2DO TL 50' PRESS. ( PIPELINE EAS HOUSE BLOWUP NOTE PROPERTY DESCRIPTION —7.5' EASMT. SIOE a REM LOT c, LASOSSI SUSDPASION, ACCORDING TO THE PLAT RECORDED FEBRUMY H, R9911N BOOK 319 AT PACE 310 AS RECEPTION NO. 2144581. COUNTY OF EAGLE STATE OF 4YM.ORADO IMPROVEMENT LOCATION CERTIFICATE I HEREBYCERTIFY THAT THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED FOR .SEE 4 BELOW ,T, ,THAT IT IS NOT A LAND SURVEY PLAT OR IMPROVEMENT SURVEY PLA AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE IMPROVEMENT LINES. I FURTHER CERTIFY THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE, 08/24/01,EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENT CROSSING OR BURDENING ANY PART OF SAID PARCEL. AS NOTED. TITLE COMMITMENT PROVIDED BY: STEWART TITLE CO. .ORDER # 01029650 4 ALPINE BANK 4 JOHN WOOD AND ROBIN WOOD m°0""1p°1p`5y p1 ��G\ST¢/�� p�. xM1 BY Fa THE SEXTON SURVEY CO BRIldB TEIEi1?:.5. 31944 128 WEST 3F' STREET 29t. ' RIFLE CO. 81650 DATE D ,{ 970-625-3711 970-945-4700 JOB N0. 01=,798;vSS10HP�"' TYPICAL YARD LANSCAPED SURFACE OR AGGREATE PAVED SURFACE CARD PROCTOR BACKFILL OR CLASS 6 ROAD BASE TRENCH CROSS-SECTION FOR 3DR-.26 HDPE OR SCHED-40 PIPES N.T.S. 2" DIA. SCH 40 PERFORATED DISTRIBUTION—� LATERAL (PRESSURIZED) PIPE INSTALLED AT THE TOP OF THE CHAMBER TOOT E MIDPOINT OF THE TERMINAL END CHAMBER. EN OF PIPE CAPPED, INSTALED 4" INSPECTION PORT (TYP.). 4" DIA. 4" DIA. SOLID SCHEDULE 40 GENERAL LOCI EXISTING 2" PRESSURE EFFLUENT TRANSPORT PIPE. � EXISTING 30" DIA, BY 10' DEEP PUMP BASIN ASSEMBLY \ DOSING TANK, INSTALLED DUPLEX P3005 \ PUMP DdSfNG ASSEMBLY. THE DOSING VOLUME IS 80 GALLONS, EXISTING WELL / \ NEW UTILITY BATHROOM CONSTRUCTED IN NEW GARAGE / FOR USE BY HOMEOWNER INSTALLED TWO-WAY CLEANOUT INSTALLED 4" SDR-2 C AT 2% / BEDDED W/ LAS 6 ABC NEW UTILITY BATHROOM SERVICE PIPE INSTA LED TO F��SnLc EXISTING SEPTIC TANK SIDE INL T PORT W/ SANITARY TEE ACCESSIBLE FROM ACC SS LID. yOGS� EXISTING 2-COMPARTMENT 1000 GAL. CONCRETE SEPTIC TANK W/ EFFLUENT FILTER INSTALLED ON THE OUTLET OF THE KCNDARY CHAMBER. XIS G 4" SEWAGE PIPE XISTING WO -WAY CLEANOUT 10 CIO °00 �FFs -----� RONCE LANE ------ //—x--z7---Z ----- ------ \ oy�0 e less) INSTALLED 39 TRENCH CHAMBERS IN 3 ROWS OF 13, A TOTAL OF 600 SO, FT, CT�ON T (TYP. OF AREA IS PROVIDED. LOCATION OF TRENCHES MEET COUNTY SETBACK ER PIP REQUIREMENTS. THE SYSTEM IS PLUMBED FOR SERIAL DISTRIBUTION. THE CHAMBERS IN EACH TRENCH ARE INSTALLED ON LEVEL GRADE, THE MAXIMUM DEPTH OF ANY TRENCH DOES c' NOT EXCEED 36". EXISTING GRADE AT PROPOSED 1 ` TRENCH LOCATION IS APPROXIMATELY \ 3' FEET HIGHER THAN THE SEPTIC TANK LIMITS EXCAVATON AN ELECT BACKFILL \ 50' WIDE HIGH PRESSURE GAS LINE EASEMENT 0 RE \\ E ISTING IRRIGATION�OITCH as /EXISTING WELL �4 28377 MEN \ �' NEW SHED \ �?r!yJ'9/ONAL E� mrrrarn�" JOHN PUTNAM PROPERTY + LOT 4, GABOSSI SUBDIVISION PUTNAM RESIDENCE EXISTING OWTS WITH GARAGE SERVICE OPRIS ENGINEERING, LLC. AB —RECORD OWTS DRAWING PROPERTY LINE 20097 Putnam—AB—OY/TS—REVISED-6-2-76.dwg 502 MAIN STREET, SUITE A3 CARBONDALE, CO 81623 (s7o) 7o4—o3t1 YTN I CK, DR. PER � DATE 6/2/16 FILE N0, ISHEET 1 2oos7.o2 � of 1 z o m C 0 X D Z � � Dz (/) 0 m � � o � II cn x co — o rz <v)D �X Z O ry = m z D