HomeMy WebLinkAbout178 Wildflower Ln - 194122205009Work Classification:New
4343 OCEAN COURSE DR S
JACKSONVILLE BEACH FL 32250-
Address Owner Information
Permit Status:Active
Project Address
194122205009
Permit Type:OWTS Permit
Permit NO.OWTS-5-14-10649
Expires: 9/19/2014Issue Date:5/22/2014
Parcel No.
178 WILDFLOWER LN
Private Wastewater
System
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone: (904)238-3908
Cell:
Inspection
For Inspections call:(970) 328-8755
Inspections:
IVR
PhoneEngineer(s)
406-388-7504ELIMINITE, INC
Contractor(s)Phone Primary ContractorLicense Number
Holland Creek (970)343-0229 Yes04-14
JOSEPH & BRENDA ADEEB
Permitted Construction / Details:
Install exactly as depicted on the design done by Thomas J. Kallenbach, PE stamped, signed and dated
March 10, 2014.
System consists of a Simplex 820 grinder system and a FLXX 2,500 gallon 3 compartment septic tank with
electric lift station connected to the state approved 27 lot cluster system located on tract AA, red Sky
Ranch.
Certification of proper installation and as-built drawings are required to be submitted to Eagle County
Environmental Health prior to final approval and use of the system.
Issued by: Environmental Health Department, Eagle County, CO
May 22, 2014
Date
Customer Copy
Ray Merry
CONDITIONS:
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH
LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
Work Classification:New
4343 OCEAN COURSE DR S
JACKSONVILLE BEACH FL 32250-
Address Owner Information
Permit Status:Active
Project Address
194122205009
Permit Type:OWTS Permit
Permit NO.OWTS-5-14-10649
Expires: 9/19/2014Issue Date:5/22/2014
Parcel No.
178 WILDFLOWER LN
Private Wastewater
System
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone: (904)238-3908
Cell:
Inspection
For Inspections call:(970) 328-8755
Inspections:
IVR
PhoneEngineer(s)
406-388-7504ELIMINITE, INC
Contractor(s)Phone Primary ContractorLicense Number
Holland Creek (970)343-0229 Yes04-14
JOSEPH & BRENDA ADEEB
Permitted Construction / Details:
Install exactly as depicted on the design done by Thomas J. Kallenbach, PE stamped, signed and dated
March 10, 2014.
System consists of a Simplex 820 grinder system and a FLXX 2,500 gallon 3 compartment septic tank with
electric lift station connected to the state approved 27 lot cluster system located on tract AA, red Sky
Ranch.
Certification of proper installation and as-built drawings are required to be submitted to Eagle County
Environmental Health prior to final approval and use of the system.
Office Copy
May 22, 2014
Issued by: Environmental Health Department, Eagle County, CO Date
Ray Merry
CONDITIONS:
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH
LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.eaglecounty.us
EAGLE COUNTY
P.O. Box 179
500 Broadway
Eagle, GO 81631
www.eaglecounty.us
PERMIT APPLICATION FOR ONSITE WASTEWATER TREATMENT SYSTEM
OWTS PERMiT # —/ BUILDING PERMIT # ES —I
INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEE SCHEDULE
APPLICATION FEE $800.00 MAJOR REPAIR FEE $800.00 MINOR REPAIR FEE 00.00
This fee includes the OWTS Permit, Site Evaluation (Percolation Test, or Soil Profile Observation) and Final
Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction site visit or
consultation is needed. The re -inspection fee is $135.00
Make all remittance payable to: Eagle County Treasurer.
Property Owner: Joe and Brenda Adeeb Phone: 904-880-8310
Mailing Address: c/o Holland Creek Metro, 28 second St, Suite email
213, Edwards CC 81532
hollandcreekwatert@centurylink.net
Registered Professional Engineer: Thomas Kallenbach _Phone: 406-581-1613
Applicant or Contact Person:
Holland Creek Metro 970-569-3045
Phone: _
Licensed Systems Contractor: Donald Odell License #
Company / DBA:
Holland Creek Metro
Phone:
Mailing Address: same email
4-14
cell 970-331-9057
same
Permit Application is for: X New Installation Alteration Repair
Location of Proposed Onsite Wastewater Treatment System:
Legal Description: _ Lot 35 Red Sky Ranch
Tax Parcel Number: 1941-222 05-009 Lot Size: 0.858
Assessor's Link: www.earJecountv.us/uatiel
Physical Address:
Building Type:
178 Wildflower Lane, Wolcott, CO.81655
Residential / Single Family
Residential / Multi Family
Number of Bedrooms: 5
Number of Bedrooms:
Commercial / Industrial* Type of Use:
*These systems require design my a Registered Professional Engineer
Type of Water Supply: Private Well Spring Surface X Public
If Public Name of Supplier:
PSWID: CO-0119673- Red Sky Ranch water treatment facility
Applicant Signature: vim`
Office Use Only
Amount Paid: Receipt #: �� �% �OCheck #:L Date:
June 8, 2015
Joe & Brenda Adeeb
c/o Holland Creek Metro
28 Second St, Suite 213
Edwards, CO 81632
RE: Final approval of septic permit OWTS-7-14-10649; Tax parcel #194122205009;
Property location: 178 Wildflower Lane, Wolcott Area
Joe:
This letter is to inform you that the above-referenced septic permit has been inspected and
finalized. This permit was approved and sized for a 5 bedroom dwelling. Additional information
about the maintenance your septic system needs as well as information about private wells can be
accessed through web site links provided on the Environmental Health Department’s home page
at http://www.eaglecounty.us/envHealth/
Be aware that changes in the use of your property or alterations of your building may
require commensurate changes to, or relocation of, your septic system. Landscape features,
trees with tap roots, irrigation systems and parking areas above the drain field can cause
premature system failure. It is equally important that you notice and immediately repair
dripping faucets and hissing toilets as this will certainly cause the system to fail. By
following a few simple guidelines, like avoiding grease or other additives down the drain and
making sure your septic tank is on a pumping schedule, your system has been designed to
last for many years.
If you have any questions regarding this information, please contact us at (970) 328-8755 and
reference the OWTS septic permit number.
Sincerely,
Terri Vroman
Administrative Technician IV
cc: OWTS permit folder
Energov electronic file
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.eaglecounty.us
RAYMOND P. MERRY, REHS
Director
5/8/2014
Eagle County Government Mail - OWTS application parcel 1941-222-05-009
F by -SIC
EAGLE COU
OWTS application parcel 1941-222-05-009
Holland Creek Water Dept <hollandcreekwater@centurylink.net>
To: environment@eaglecounty.us
Terri Vroman <terri.vroman@eaglecounty.us>
Thu, May 8, 2014 at 11:16 AM
Attached are electronic copies of an application and OWTS design for lot 35, 178 Wildflower Lane in Wolcott,
CO. 81655 in Red Sky Ranch.
This home will be connected to the State Licensed 27 unit system serving all of tract AA (COX66027) therefore
does not have an individual soil treatment area on the lot.
I will bring the hard copy of the application and drawing along with the fees to your office this afternoon. Thank
you. Don O
Donald Odell CWP, CIOWTS-A
Holland Creek Metropolitan District
970-569-3045 water/wastewater office
hollandcreekwater@centurylink. net
i �4Home of the 2015 Alpine World Ski Championships!
2 attachments
ECO OWTS application RSR lot 35.pdf
759K
•� ACAD-Adeeb to Metro Dist 1-02-14-D-Size Layout (2).pdf
818K
hftps:Hmai I .g oog I e.corrdmai I/u/0/?ui=2&i k=30478a9c52&\A evw pt&search= i nbox&th=145dcd6dfOe6a459&si ml=145dcd6dfOe6a459 1 /1
June 5, 2015
Raymond P. Merry, RHES
Environmental Health Director
Eagle County Government
P.O. Box 179
Eagle, Colorado 81631
Subject: Onsite Wastewater System Final Certification, 178 Wildflower Lane, Red Sky Ranch Lot 35, Tract AA, Wolcott,
CO 81655.
Dear Mr. Merry:
Please accept this letter as final certification of the installation of the wastewater system for the above referenced
property. Holland Creek Metro District completed installation and I have reviewed their work and found it to be in
compliance with the approved plans. Record drawings are attached.
If you have questions, please contact me at your convenience.
Sincerely,
Thomas J. Kallenbach, P.E.
Lift Station, N 39 41.460 W 106 40.758
57’ 0”
41’0”
Transformer to center of tank 24’
Water vault to center of tank 24 ‘
Center septic tank is N 39 41.447 W 106 40.783
Septic layout
178 Wildflower Lane, Wolcott. CO. 81655
Discharges into force main to
common system
MAIN LEVELFF:7395.7LOWER LEVELFF:7384.7GARAGEFF:7395.2739674007390738073907380738873867384738473
9
4 7398739673947392738873867384738273927392
738073827394739673927390738673847390738673907388738673847
3
8
2
7
3
8
6 1 12" SDR 11 HDPE PIPEHDPE CLEANOUT. BRING CLEANOUT VERTICAL:,7+60227+5$',8625(48,9$/(17),77,1*668&+$67:2ELBOWS.ZOELLER MODEL 820PACKAGED GRINDERPUMP STATION2500 GAL. PRECASTCONCRETE SEPTIC TANKCONTROL PANEL LOCATION6&+BUILDING SEWERWITH CLEANOUTFITTINGSSTA-RITE S.T.E.P. PLUS10 GPM HIGH HEADDUPLEX TURBINE PUMPSCONNECTION TO STATEAPPROVED PRESSURESEWER.ISOLATION VALVEINSTALL HDPE PIPE BELOW FROST PENETRATION DEPTH.PUMPS REQUIRE 240 V. CONTROL PANEL CONTROL CIRCUITS REQUIREINDEPENDENT 120 V CIRCUITS.INSTALL PRECAST SEPTIC TANK AND PACKAGED GRINDER STATIONACCORDING TO MANUFACTURERS INSTRUCTIONS.INSTALL CLEANOUTS IN ACCORDANCE WITH EAGLE COUNTY REGULATIONS.'212786($6,1*/((/%2:72%5,1*7+(&/($1287727+(SURFACE. USE EITHER A SMOOTH RADIUS OR A COMBINATION OF FITTINGS.INSTALL A HOLLAND CREEK METRO DISTRICT APPROVED ISOLATION VALVEBETWEEN THE SEPTIC TANK AND PUBLIC PRESSURE SEWER PIPE.LOCATION OF COMPONENTS SHOWN IS APPROXIMATE. CONSULT HOLLANDCREEK METRO DISTRICT FOR FINAL LOCATIONS.NO UTILITIES HAVE BEEN IDENTIFIED. IT IS THE RESPONSIBILITY OF THECONTRACTOR TO CONTACT THE APPROPRIATE UTILITY LOCATING SERVICES.STA-RITE S.T.E.P. PLUSD SERIES EFFLUENT PUMP.DUPLEX ARRANGEMENTRED SKY RANCH TRACT AA LOT 35178 WILDFLOWER LANEDNTS1/1PREPARED BY:THOMAS J. KALLENBACH, P.E.GRINDER PUMP OPERATING POINTMARCH 10, 2014