Permit
Permit No. OWTS-026751-2023
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 5/16/2023 Expires: 9/8/2024
On-Site Wastewater
Treatement System
Project Address Parcel Number
222 GREEN MEADOW DR, EL JEBEL AREA,239122403001
Owner Information Address
John & Mandy Gross & Kotzman P.O. Box 1084
LaPorte, CO 80535
Phone: (970) 581-7983
Cell:
Email: JohnGross888@gmail.com
Inspections:
For Inspections Call: (970)
328-8755
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Permitted Construction / Details:
Install the new system exactly as depicted in the CBO Inc design dated February 8th, 2022, stamped and signed on
February 21st, 2022 by Romeo A Baylosis, PE. This system is designed to accommodate the maximum daily flows for
a 3 bedroom residence and a proposed future bedroom addition.
This OWTS consists of one sewer line from the residence. A Valley Precast 1,250 gallon, concrete, two-compartment
septic tank will be used with an effluent filter in the outlet tee. A PolyLok distribution box equipped with flow
equalizers will be accessible at grade. The STA consists of four over excavated 3' wide x 52' long trenches with a 6
inch sand filter. One 39" wide by 52' long GeoMat filter fabric will be placed over the sand filter in each trench.
Gradation analysis must confirm that sand is secondary media. The water line location should be noted on the
record drawing.
A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County
(EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor
without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503,
C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system or occupancy of the dwelling.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS
OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Salinsky
Date
May 16, 2023
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Friday, March 22, 2024 1
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-026751-2023
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 5/16/2023 Expires: 9/13/2023
On-Site Wastewater
Treatement System
Project Address Parcel Number
222 GREEN MEADOW DR, EL JEBEL AREA,239122403001
Owner Information Address
John & Mandy Gross & Kotzman P.O. Box 1084
LaPorte, CO 80535
Phone: (970) 581-7983
Cell:
Email: JohnGross888@gmail.com
Inspections:
For Inspections Call: (970)
328-8755
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Permitted Construction / Details:
Install the new system exactly as depicted in the CBO Inc design dated February 8th, 2022, stamped and signed on
February 21st, 2022 by Romeo A Baylosis, PE. This system is designed to accommodate the maximum daily flows for
a 3 bedroom residence and a proposed future bedroom addition.
This OWTS consists of one sewer line from the residence. A Valley Precast 1,250 gallon, concrete, two-compartment
septic tank will be used with an effluent filter in the outlet tee. A PolyLok distribution box equipped with flow
equalizers will be accessible at grade. The STA consists of four over excavated 3' wide x 52' long trenches with a 6
inch sand filter. One 39" wide by 52' long GeoMat filter fabric will be placed over the sand filter in each trench.
Gradation analysis must confirm that sand is secondary media. The water line location should be noted on the
record drawing.
A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County
(EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor
without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503,
C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system or occupancy of the dwelling.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS
OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Salinsky
Date
May 16, 2023
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Tuesday, May 16, 2023 1
INSPECTION WORKSHEET (INSP-540902-2025)
FOR EAGLE COUNTY GOVERNMENT
OWTS-026751-2023Case Number:Case Module:Permit Management
06/26/2024 ApprovedInspection Status:Inspection Date:
OWTS Final InspectionInspection Type:Inspector:Kirk Weems
Job Address:Parcel Number:222 Green Meadow Dr
El Jebel Area, CO
239122403001
Company Name NameContact Type
Applicant John & Mandy Gross & Kotzman
Engineer RB Civil LLC Romeo & Danica Baylosis/ Weappa
Engineer Consultant CBO Septic Consulting Carla Ostberg
Owner John & Mandy Gross & Kotzman
CommentsPassedChecklist Item
True 06/26/2024 - confirm1250 gal poly tankSeptic Tank - Septic Tank
True Submitted with PE Final Docs.Record Drawing - Record Drawing
True Submitted with PE Final Docs.Record Photos - Record Photos
True Submitted with PE Design Docs.Site and Soil - Site & Soil
True Received 06/09/2025Final Certification Letter - Final Certification Letter
True 06/26/2024 - All components appear to be installed in general
compliance with approved PE design.
General Plan - General Plan
True 06/26/2024 - confirm 4 trenches, each with 52' x 39" geomat. Dbox
installed with flow equalizers.
Soil Treatment Area (STA) - Soil Treatment Area (STA)
True Licensed Contractor - Dennis Brown
OWTSPL-000352-2024
Dennis Brown
Identification of Systems Contractor - Identification of
Systems Contractor
June 13, 2025 Page 1 of 1P.O. Box 179, 500 Broadway, Eagle, CO 81631-0179
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-026751-2023
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Final
Issue Date: 5/16/2023 Expires: 9/8/2024
On-Site Wastewater
Treatement System
Project Address Parcel Number
222 GREEN MEADOW DR, EL JEBEL AREA,239122403001
Owner Information Address
John & Mandy Gross & Kotzman P.O. Box 1084
LaPorte, CO 80535
Phone:
Cell: (970) 581-7983
Email: JohnGross888@gmail.com
Inspections:
For Inspections Call: (970)
328-8755
Engineer Phone Email
CBO Septic Consulting, Carla Ostberg (970) 309-0525 carla.ostberg@gmail.com
Contractor License Number Phone Email
Dennis Brown Excavation dl.brown@live.com(970) 379-8615OWTSPL-000390-20
25
Permitted Construction / Details:
Install the new system exactly as depicted in the CBO Inc design dated February 8th, 2022, stamped and signed on
February 21st, 2022 by Romeo A Baylosis, PE. This system is designed to accommodate the maximum daily flows for
a 3 bedroom residence and a proposed future bedroom addition.
This OWTS consists of one sewer line from the residence. A Valley Precast 1,250 gallon, concrete, two-compartment
septic tank will be used with an effluent filter in the outlet tee. A PolyLok distribution box equipped with flow
equalizers will be accessible at grade. The STA consists of four over excavated 3' wide x 52' long trenches with a 6
inch sand filter. One 39" wide by 52' long GeoMat filter fabric will be placed over the sand filter in each trench.
Gradation analysis must confirm that sand is secondary media. The water line location should be noted on the
record drawing.
A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County
(EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor
without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503,
C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system or occupancy of the dwelling.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS
OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Salinsky
Date
May 16, 2023
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Friday, June 13, 2025 1
CBO Inc.
129 Cains Lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
June 5, 2025 Project No. C1677
John Gross
Johngross888@gmail.com
Onsite Wastewater Treatment System Design
3-Bedroom Residence + 1 Future Bedroom
222 Green Meadow Drive
Eagle County, Colorado
John,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on June 25, 2024
for the subject property. Dennis Brown installed the system.
The OWTS design is based on 4-bedrooms (3 bedrooms in the residence plus a future bedroom). An
average daily wastewater flow of 525 GPD was used.
The 4-inch diameter SDR 35 sewer line exiting the residence has a double-sweep clean out and a
minimum 2% grade to the septic tank.
The system installation included a 1250-gallon, two-compartment concrete Norwesco® poly septic tank
with an effluent filter on the outlet tee. This filter must be cleaned annually, or as needed. Risers
bring the manhole lids to grade for access.
Effluent gravity flows to a distribution box and then to four 3’ wide x 52’ long trenches. The distribution
box is accessible from grade with flow equalizers. Each trench has 6-inches of sand filter material placed
in the trench excavation. One 39-inch wide GeoMat™ sheet was placed on top of the sand filter material
in each trench. A 4-inch diameter perforated pipe runs down the center of the GeoMat™, under the top
layer of fabric. Each trench has a total of 52 linear feet of GeoMat™ for a total of 208 linear feet of 39”
GeoMat™ and 624 square feet infiltrative area. Inspection ports were installed at the beginning and end
of each trench. Ports may be cut to grade and covered with a sprinkler box for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent on the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc.
Carla Ostberg, MPH, REHS
Distribution box Effluent filter with handle extension
Distribution box Clean out near foundation
Sewer pipe clean out
View of septic tank
1250 gal tank
Sewer line from tank to dbox perf pipe on GeoMat
Inlet Outlet
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-026751-2023
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 5/16/2023 Expires: 9/13/2023
On-Site Wastewater
Treatement System
Project Address Parcel Number
222 GREEN MEADOW DR, EL JEBEL AREA,239122403001
Owner Information Address
John & Mandy Gross & Kotzman P.O. Box 1084
LaPorte, CO 80535
Phone: (970) 581-7983
Cell:
Email: JohnGross888@gmail.com
Inspections:
For Inspections Call: (970)
328-8755
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Permitted Construction / Details:
Install the new system exactly as depicted in the CBO Inc design dated February 8th, 2022, stamped and signed on
February 21st, 2022 by Romeo A Baylosis, PE. This system is designed to accommodate the maximum daily flows for
a 3 bedroom residence and a proposed future bedroom addition.
This OWTS consists of one sewer line from the residence. A Valley Precast 1,250 gallon, concrete, two-compartment
septic tank will be used with an effluent filter in the outlet tee. A PolyLok distribution box equipped with flow
equalizers will be accessible at grade. The STA consists of four over excavated 3' wide x 52' long trenches with a 6
inch sand filter. One 39" wide by 52' long GeoMat filter fabric will be placed over the sand filter in each trench.
Gradation analysis must confirm that sand is secondary media. The water line location should be noted on the
record drawing.
A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County
(EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor
without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503,
C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system or occupancy of the dwelling.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS
OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Salinsky
Date
May 16, 2023
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Tuesday, May 16, 2023 1
832‐R‐13‐002
129 Cains Lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
February 8, 2022 Project No. C1677
John Gross
Johngross888@gmail.com
Onsite Wastewater Treatment System Design
3-Bedroom Residence + 1 Future Bedroom
221 Green Meadow Drive
Eagle County, Colorado
John,
CBO Inc. has completed an onsite wastewater treatment system (OWTS) design for the subject
residence. The property is located outside of Basalt, in an area where OWTSs are necessary.
Legal Description: Subdivision: OAK RIDGE I Lot: 1 BK-0640 PG-0585 DC 04-06-93
Parcel ID: 2391-224-03-001
SITE CONDITIONS The property is currently undeveloped. A 3-bedroom, single-family residence with the potential for an
additional bedroom in the future is proposed.
The residence will be served potable water from a community water system. No water line will come
within 25-feet of any OWTS component.
The proposed soil treatment area (STA) will be located to the southwest of the proposed residence. The
area has an approximate 10-12% slope to the southwest.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
prior to construction of the STA.
SUBSURFACE The subsurface was investigated by Kumar and Associates and findings are documented in a report
(enclosed) dated January 2, 2022, Project No 19-7-723.
Test Pits 1, 2, and 6 were excavated for the purpose of determining feasibility of construction of the
proposed STA.
Pit 1 consisted brown topsoil to 1.0-foot, underlain by silty clay loam to clay loam to 4.5-feet, underlain by
tan sand and gravel to a maximum depth of 6.5-feet. This horizon is described as sand and gravel, silty
with cobbles and probably boulders, medium dense, slightly moist, tan basalt rock, calcareous,
cemented. We typically describe this horizon as a calcareous clay matrix which grades as Soil Type 2.
No bedrock or groundwater was encountered.
Page 2
Pit 2 consisted of topsoil to 1.5-feet, underlain by silty clay loam to clay loam to 4.0-feet, underlain by tan
sand and gravel to a maximum depth explored of 7.0-feet where practical digging refusal was
encountered. No bedrock or groundwater was encountered.
Pit 6 consisted of topsoil to 1.5-feet, underlain by silty clay loam to clay loam to 3.0-feet, underlain by tan
sand and gravel to a maximum depth explored of 8.0-feet where practical digging refusal was
encountered. No bedrock or groundwater was encountered.
A sample of the clay loam horizon was taken from Pit 1 at 2.5 to 3.0-feet and consisted of 1% gravel,
20% sand, 51% silt, and 28% clay.
A sample of the sand and gravel horizon (calcareous clay matrix) from Pit 2 at 7.0 to 7.5-feet and
consisted of 23% gravel, 49% sand, 24% silt, and 4% clay.
These findings are consistent with soils typical in this area of Missouri Heights. STA sizing will be based
on Soil Type 2. A long term acceptance rate (LTAR) of 0.6 gallons per square foot will be used to
design the OWTS, in accordance with Eagle County OWTS Regulation.
Installation of the infiltrative area must occur just below the clay loam horizon, into the calcareous clay
matrix.
DESIGN SPECIFICATIONS
Design Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms = 450 GPD + 75 GPD (4th bedroom) =
525 GPD
LTAR = 0.6 GPD/SF
525 GPD / 0.6 GPD/SF x 1.0 (gravity trenches) x 0.7 (GeoMat™ with min. 6” sand) = 613 SF
The OWTS design is based on 3-bedrooms in the residence + 1 future bedroom = 4 total bedrooms. An
average daily wastewater flow of 525 GPD will be used.
For the purposes of this OWTS design, Benchmark Elevation at grade 7263’ has been established as
100’ Main Level Finished Floor (FF). Lower Level FF is 90’ 10 ¼” (7253.85’). CBO Inc. should be
notified of any discrepancies or problems with grade elevations of proposed components during
installation of the OWTS.
OWTS Component Minimum Elevation
Primary Tank Inlet Invert Approximate horizontal distance 56’ / min. 2% fall /
min. 14” fall
Distribution Box Approximate horizontal distance 13’ / min. 1% fall /
min. 1.625” fall
Infiltrative Surface Approximate horizontal distance to furthest trench
24’ / min. 1% fall / min. 3” fall
*Elevations are based upon standard OWTS installation practices. Component elevations may change during
installation due to site conditions. Minimum grade refers to piping between components.
The 4-inch diameter SDR 35 sewer line exiting the residence must have a double-sweep clean out and a
minimum 2% grade to the septic tank.
The system installation must include a minimum 1250-gallon, two-compartment concrete septic tank with
an effluent filter on the outlet tee. Any state-approved poly septic tank or concrete septic tank may be
Page 3
substituted. Risers must bring the manhole lids to grade for access. If more than one riser is added to
the septic tank, an extension handle must be installed on the effluent filter.
Effluent will gravity flow to a distribution box, and then to four 3’ wide x 52’ long trenches. The distribution
box must be accessible from grade and must have flow equalizers, or similar product, installed on each
outlet pipe in the distribution box to assure equal flow to each trench.
Each trench must have a minimum of 6-inches of sand filter material placed in each trench over-
excavation. Sand filter material must be clean, coarse sand, all passing a screen having four meshes to the
inch. The sand must have an effective size between 0.15 and 0.60 mm. The uniformity coefficient must be
7.0 or less. Material meeting ASTM 33, for concrete sand, with three percent or less fines passing 200 mesh
sieve may be used. A gradation of the sand media must be submitted to this office prior to
obtaining the sand.
One 39-inch wide GeoMat™ will be placed on top of the sand filter material on each trench. A 4-inch
diameter perforated pipe will be placed down the center of the GeoMat™, under the top layer of fabric.
Each trench will have a total of 52 linear feet of GeoMat™ for a total of 208 linear feet of 39” GeoMat™
and 624 square feet infiltrative area. All material associated with the GeoMat™ installation must be
proprietary products associated with the GeoMat™, including the geotextile fabric. Manufacturer instructions
must be followed regarding installation of the GeoMat™.
There must be at least 4-feet of undisturbed soil between each trench. Inspection ports must be installed
at the front corners of each trench to the side of the GeoMat™ and the end inspection ports will be tied
onto the end of the laterals. Ports may be cut to grade and placed in sprinkler boxes for access. There
shall be no cobble-sized (<2.5”) or greater rock in final cover over the GeoMat™.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
COMPONENT MANUFACTURER MODEL NO. COMMENTS
Septic Tank Valley Precast Item # 1250T-2CP 1250-gallon, two-compartment concrete septic tank (can substitute for any state-approved poly tank) Biotube Effluent Filter Orenco® Full Size Effluent Filter and housing Risers and Lids Orenco® Risers and Lids
Distribution Box PolyLok Distribution box, risers, lid, and
flow equalizers (4) GeoMat™ GeoMatrix Systems, LLC 208 ‘GeoMat™ (39” wide sheets)
The component manufacturers are typical of applications used by contractors and engineers in this area.
Alternatives may be considered or recommended by contacting our office. Construction must be
according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided
by Eagle County Environmental Health Department, and this design.
Page 4
INSTALLATION CONTRACTOR
CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours
in advance to observe the installation.
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
Page 5
2-21-2022
ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, CBO Inc. should be notified. All OWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Please call with questions.
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE
KOTZMAN, MANDY -
GROSS, JOHN E.
PO BOX 1084
LAPORTE, CO 80535-1084
Account: R027441
Tax Area: 007 - EL JEBEL (AREA) -
007
Acres: 2.710
Parcel: 2391-224-03-001
Situs Address:
000221 GREEN MEADOW DR
EL JEBEL AREA, 0
Value Summary
Value By:Market Override
Land (1)$2,580 N/A
Total $2,580 $2,580
Legal Description
Subdivision: OAK RIDGE I Lot: 1 BK-0640 PG-0585 DC 04-06-93
Sale Data
Doc. #Sale Date Deed Type Validity Verified Sale Price Ratio Adj. Price Ratio Time Adj.
Price
Ratio
202000257 01/06/2020 WD UI Y $185,000 1.39 $185,000 1.39 $185,000 1.39
Land Occurrence 1
Abstract Code 4117 - IRRIGATED LAND-AGRICLTRL.Percentage 100.0
Use Code 4000 - AGRICULTURAL Neighborhood 1010 - OAK RIDGE I
Land Code 5199 - IRR FARM LAND 2 5 TON Super Neighborhood 55 - BASALT/EL JEBEL AG
PROPERTIES
Size 2.71
SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT
Land A 2.713
Total 2.713
Value Rate Rate Rate Rate
$2,580 952.03
Property Record Card
Eagle
A#: R027441 P#: 239122403001 As of: 01/01/2022 Page 1 of 2
Abstract Summary
Code Classification Actual Value Taxable
Value
Actual
Override
Taxable
Override
4117 IRRIGATED LAND-AGRICLTRL.$2,580 $750 NA NA
Total $2,580 $750 NA NA
Property Record Card
Eagle
A#: R027441 P#: 239122403001 As of: 01/01/2022 Page 2 of 2
• Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
• Installs in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
• Easy to clean by
simply hosing off
whenever the tank
needs pumping
• Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
• Corrosion-proof
construction, to
ensure long life
• Lifetime warranty
Residential Biotube® Effluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a lifetime warranty. They prevent large solids from leaving
the tank, dramatically improving wastewater quality and extending the life
of residential drainfields.
Standard Features & Benefits
• Alarm available, to
signal the need for
cleaning
• Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
• Custom and
commercial sizes
available
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes’ entire
surface for filtering.
Particles larger than
the Biotube’s mesh
are prevented from
leaving the tank.
Optional
Features &
Benefits
Biotube
Filtering
Process
8-in. (200-mm)
Base Inlet Filter
4-in. (100-mm)
Insert Filter
4-in. (100-mm) Biotube Jr.
(4-in. Biotube cartridge avail-
able separately as Insert Filter)
Orenco’s superior effluent filters resist clogging better than all other brands. Our stan-
dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term
protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at
half the size of our standard model, has more filtering capacity than the full-sized filters
sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter
is ideal. And for low-profile tanks, there’s the Base Inlet Filter.
* Covered by patent numbers 5,492,635 and 4,439,323
4-in. (100-mm) Biotube Effluent Filter
APS-FT-1
Rev. 3.4 © 11/10
Orenco Systems®, Inc.
To Order
Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on
“Distributor Locator.”
Nomenclatures
Riser
wall
Tank wall
Filter housing
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube® filter cartridge
Solid base
4-in. Biotube
Effluent Filter
4-in. Biotube Jr.
4-in. Biotube Filter (standard)
4-in. Biotube Jr. (includes cartridge and housing)
Distributed By:
8-in. Biotube Filter (base inlet model)
4-in. Biotube Filter Insert (cartridge only)
Junior series
FT J0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Blank = 1/8" filtration
P = 1/16" filtration
Insert
FT i0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
-
For customized options (e.g., NC
indicates North Carolina regions)
-
Blank = 1/8" filtration
P = 1/16" filtration
FT 04
Biotube effluent filter series
Filter diameter (inches)
Housing height: 36" and 44" are standard
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Cartridge height: 28" and 36" are standard
-
Blank = 1/8" filtration
P = 1/16" filtration
W = fits Type 3034 outlet pipe
S = fits Schedule 40 outlet pipe
FT 2208 14 B
Biotube effluent filter series
Housing height: 22" standard
Cartridge height: 14" standard
Options:
A = float bracket
FS = 2" outlet orifice
FSO = 2" outlet orifice and overflow plate*
Base inlet model
-
Blank = 1/8" filtration
P = 1/16" filtration
Filter diameter (inches)
08 = 8"
* Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT