HomeMy WebLinkAbout705 Vista Hi Dr - 239134101001Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-024628-2022 Permit Type: OWTS Permit Work Classification: New Permit Status: Final Issue Date: 6/30/2022 Expires: 8/14/2023 On-Site Wastewater Treatement System Project Address Parcel Number 705 VISTA HI DR, EL JEBEL AREA,239134101001 Owner Information Address David Hess PO Box 1980 Carbondale, CO 81623 Phone: Cell: (215) 360-2969 Email: phillydave@gmail.com Inspections: For Inspections Call: (970) 328-8755 Engineer Phone Email CBO Septic Consulting, Carla Ostberg (970) 309-0525 carla.ostberg@gmail.com Contractor License Number Phone Email E&L Trucking & Excavation, INC.eandlexcavation@aol.com(970) 309-3057OWTSPL-000410-20 25 Permitted Construction / Details: Install the new system exactly as depicted in the CBO Inc design dated August 19th, 2021, stamped and signed on September 3rd, 2021. This system is designed to accommodate the maximum daily flows for a 4 bedroom house. The OWTS consists of one sewer line from the residence. A Valley Precast 1,250 gallon, two-chamber septic tank with an effluent filter in the outlet tee. A PolyLok 6-Hole Distribution Box equipped with flow equalizers will be accessible at grade. The STA consists of 6 shallow trenches of 11 Infiltrator Quick 4 Plus Standard chambers for a total of 66. A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County (EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503, C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Danielle Salinsky Date June 30, 2022 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Tuesday, April 1, 2025 1 Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-024628-2022 Permit Type: OWTS Permit Work Classification: New Permit Status: Active Issue Date: 6/30/2022 Expires: 8/14/2023 On-Site Wastewater Treatement System Project Address Parcel Number 705 VISTA HI DR, EL JEBEL AREA,239134101001 Owner Information Address David Hess 1607 South ST STE #2 Philadelphia, PA 19146 Phone: Cell: (215) 360-2969 Email: phillydave@gmail.com Inspections: For Inspections Call: (970) 328-8755 Engineer Phone Email RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com Contractor License Number Phone Email E&L Trucking & Excavation, INC.eandlexcavation@aol.com(970) 309-3057OWTSPL-000205-20 22 Permitted Construction / Details: Install the new system exactly as depicted in the CBO Inc design dated August 19th, 2021, stamped and signed on September 3rd, 2021. This system is designed to accommodate the maximum daily flows for a 4 bedroom house. The OWTS consists of one sewer line from the residence. A Valley Precast 1,250 gallon, two-chamber septic tank with an effluent filter in the outlet tee. A PolyLok 6-Hole Distribution Box equipped with flow equalizers will be accessible at grade. The STA consists of 6 shallow trenches of 11 Infiltrator Quick 4 Plus Standard chambers for a total of 66. A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County (EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503, C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Danielle Salinsky Date June 30, 2022 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Monday, February 27, 2023 1 Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-024628-2022 Permit Type: OWTS Permit Work Classification: New Permit Status: Active Issue Date: 6/30/2022 Expires: 10/28/2022 On-Site Wastewater Treatement System Project Address Parcel Number 705 VISTA HI DR, EL JEBEL AREA,239134101001 Owner Information Address David Hess 1607 South ST STE #2 Philadelphia, PA 19146 Phone: Cell: (215) 360-2969 Email: phillydave@gmail.com Inspections: For Inspections Call: (970) 328-8755 Engineer Phone Email RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com Contractor License Number Phone Email Permitted Construction / Details: Install the new system exactly as depicted in the CBO Inc design dated August 19th, 2021, stamped and signed on September 3rd, 2021. This system is designed to accommodate the maximum daily flows for a 4 bedroom house. The OWTS consists of one sewer line from the residence. A Valley Precast 1,250 gallon, two-chamber septic tank with an effluent filter in the outlet tee. A PolyLok 6-Hole Distribution Box equipped with flow equalizers will be accessible at grade. The STA consists of 6 shallow trenches of 11 Infiltrator Quick 4 Plus Standard chambers for a total of 66. A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County (EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503, C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Danielle Salinsky Date June 30, 2022 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Thursday, June 30, 2022 1 CBO Inc. 129 Cains Lane Carbondale, CO 81623 970.309.5259 carla.ostberg@gmail.com March 30, 2025 Project No. C1643 David Hess phillydave@gmail.com Onsite Wastewater Treatment System (OWTS) Installation Observations 705 Vista Hi Drive Eagle County, Colorado Permit OWTS-024628-2022 David, CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on August 9, 2023 for the subject property. E&L Trucking installed the system. The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD was used. The system installation included a 1250-gallon, two-compartment Valley Precast concrete septic tank with an effluent filter on the outlet tee. This filter must be cleaned annually, or as needed. Risers bring the manhole lids to grade for access. Effluent gravity flows to a distribution box, and then to six gravelless chamber trenches. The distribution box was accessible from grade with flow equalizers installed on each outlet pipe in the distribution box to assure equal flow to each trench. Each trench consists of 11 ‘Quick 4’ Standard Plus Infiltrator® chambers for a total of 66 chambers and 792 square feet of infiltrative area. There was at least 4-feet of undisturbed soil between each trench. Inspection ports were installed at the beginning and end of each trench. Ports may be cut to grade and placed in sprinkler boxes for access. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent on the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, CBO Inc. Carla Ostberg, MPH, REHS Tank hole prep Tank delivery View of septic tank and foundation Septic tank to distribution box D-box to field Effluent filter must be cleaned annually, or as needed. View of sewer line from foundation to tank / inlet tee All sewer lines have tracer wire Sewer line exiting foundation Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-024628-2022 Permit Type: OWTS Permit Work Classification: New Permit Status: Active Issue Date: 6/30/2022 Expires: 10/28/2022 On-Site Wastewater Treatement System Project Address Parcel Number 705 VISTA HI DR, EL JEBEL AREA,239134101001 Owner Information Address David Hess 1607 South ST STE #2 Philadelphia, PA 19146 Phone: Cell: (215) 360-2969 Email: phillydave@gmail.com Inspections: For Inspections Call: (970) 328-8755 Engineer Phone Email RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com Contractor License Number Phone Email Permitted Construction / Details: Install the new system exactly as depicted in the CBO Inc design dated August 19th, 2021, stamped and signed on September 3rd, 2021. This system is designed to accommodate the maximum daily flows for a 4 bedroom house. The OWTS consists of one sewer line from the residence. A Valley Precast 1,250 gallon, two-chamber septic tank with an effluent filter in the outlet tee. A PolyLok 6-Hole Distribution Box equipped with flow equalizers will be accessible at grade. The STA consists of 6 shallow trenches of 11 Infiltrator Quick 4 Plus Standard chambers for a total of 66. A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County (EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503, C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Danielle Salinsky Date June 30, 2022 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Thursday, June 30, 2022 1 832‐R‐13‐002 129 Cains Lane Carbondale, CO 81623 970.309.5259 carla.ostberg@gmail.com August 19, 2021 Project No. C1643 David Hess phillydave@gmail.com Subsurface Investigation and Onsite Wastewater Treatment System Design 4-Bedroom Residence 705 Vista Hi Drive Eagle County, Colorado David, CBO Inc. performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The 5.06-acre property is located outside of Basalt, in an area where OWTSs and wells are necessary. Legal Description: Subdivision: MOUNTAIN MEADOW RANCH FIL 2 Lot: 32 BK-0289 PG-0266 MAP 08-03-79 Parcel ID: 2391-341-01-001 SITE CONDITIONS The property is currently undeveloped. A single-family residence is proposed. The residence will be served potable water by an onsite well. The well will be located to the northeast of the residence. The well will be at least 50-feet from the septic tank and at least 100-feet from the proposed soil treatment area (STA). The proposed STA slopes at an approximate 20% to the south. The area is vegetated with limited native grasses and some mature pinion and juniper trees. With the proposed trench configuration, it will be possible to navigate between trees that may be desired to save. There should be no traffic or staging of material over the future STA site to avoid compaction of soils prior to construction of the STA. SUBSURFACE The subsurface was investigated on July 8, 2021 by digging two soil profile test pit excavations (Test Pits). Visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.1 The materials encountered in Test Pit #1 consisted of medium brown topsoil to 2-feet, underlain by tan to whitish calcareous clay matrix to a maximum depth explored of 5.0-feet where refusal was encountered on a large boulder. No bedrock or groundwater was encountered. The materials encountered in Test Pit #2 consisted of medium brown topsoil to 4-inches, underlain by 1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile Evaluation of Soils Training. Page 2 light brown, dense, sandy loam to 3.5-feet with a calcareous clay matrix to a maximum depth explored of 6.5-feet. No bedrock or groundwater was encountered. A sample was taken from Test Pit #1 at approximately 3-feet below grade. The soil structure grade below was moderate. Soil structure grade in Test Pit 2 was more dense (weak). The soil formed a ball and a ribbon less than 1-inch in length before breaking. Soil structure shape was blocky and consistence was friable. Soil texture was more gritty than smooth. STA sizing is based on Soil Type 2A. A long term acceptance rate (LTAR) of 0.5 gallons per square foot, will be used to design the OWTS. Digging Test Pit #1 Proposed STA Backfill Page 3 Test Pit #1 refusal on boulder Sieved sample from Test Pit #1 Ribbon less than 1-inch Page 4 View of Test Pit #2 Test Pit #2 Backfill Page 5 DESIGN SPECIFICATIONS Design Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 75 GPD (4th Bedroom) = 525 GPD LTAR = 0.5 GPD/SF 525 GPD / 0.5 GPD/SF x 1.0 (gravity trenches) x 0.7 (chambers) = 735 SF The new OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD will be used. For the purposes of this OWTS design, Benchmark Elevation at 6930’ (Finished Floor) has been established as 100’. The sewer line will exit the residence at approximately 98’. CBO Inc. should be notified of any discrepancies or problems with grade elevations of proposed components during installation of the OWTS. OWTS Component Minimum Elevation Primary Tank Inlet Invert Approximate horizontal distance to septic tank 20’ / min. 2% fall / min. 5” fall Distribution Box Approximate horizontal distance to distribution box 22’ / min. 1% fall / min. 2.75” fall Infiltrative Surface Approximate horizontal distance to STA 50’ (to farthest trench) / min. 1% fall / min. 6.25” fall *Elevations are based upon standard OWTS installation practices. Component elevations may change during installation due to site conditions. The 4-inch diameter SDR-35 sewer line exiting the residence must have a double-sweep clean out and a minimum 2% grade to the septic tank. The system installation must include a minimum 1250-gallon, two-compartment septic tank (any state- approved concrete or poly tank is acceptable) with an effluent filter on the outlet tee. Risers must bring Page 6 the manhole lids to grade for access. If more than one riser is added to the septic tank, an extension handle must be installed on the effluent filter. Effluent will gravity flow to a distribution box, and then to six gravelless chamber trenches. The distribution box must be accessible from grade and must have flow equalizers, or similar product, installed on each outlet pipe in the distribution box to assure equal flow to each trench. Each trench will consist of 11 ‘Quick 4’ Standard Plus Infiltrator® chambers for a total of 66 chambers and 792 square feet of infiltrative area. There must be at least 4-feet of undisturbed soil between each trench. Inspection ports must be installed at the beginning and end of each trench. Ports may be cut to grade and placed in sprinkler boxes for access. COMPONENT SPECIFICATIONS The component manufacturers are typical of applications used by contractors and engineers in this area. CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must be submitted, in writing, to our office for approval prior to installation. Component technical data sheets are available upon request. COMPONENT MANUFACTURER MODEL NO. COMMENTS Septic Tank Valley Precast Item # 1250T-2CP 1250-gallon, 2- compartment concrete septic tank Biotube Effluent Filter Orenco® Full Size Effluent Filter and housing Tank Risers and Lids Orenco® Double-walled PVC Risers and Lids (24” diameter) Distribution Box PolyLok D-Box 8C Poly distribution box, lids, risers, and flow equalizers Chambers Infiltrator® Standard Plus 66 ‘Quick 4’ Chambers Construction must be according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided by Eagle County Environmental Health Department, and this design. INSTALLATION CONTRACTOR CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this design. The installer must review this design thoroughly and coordinate with our office in advance of installation. Any additional conditions in this design or county permit must be completed and documented prior to final approval of the OWTS installation. Communication between the installer and this office is expected throughout the installation. INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours in advance to observe the installation. In an effort to improve the accuracy of the record drawing, we request that the installer provide a sketch of the installation, including path of the sewer lines, water line installation (if applicable), septic tank location, STA location, and measurements from building corners or another fixed objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design Page 7 Packet. Photographs of the installation and final cover are also requested to supplement our installation documentation. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high-water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3-inch. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, CBO Inc. should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The Page 8 9-3-2021 contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, CBO Inc. Reviewed By: Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE HESS, DAVID - EARY, JESSICA 1607 SOUTH ST UNIT 2 PHILADELPHIA, PA 19146-1541 Account: R023841 Tax Area: 007 - EL JEBEL (AREA) - 007 Acres: 5.060 Parcel: 2391-341-01-001 Situs Address: 000705 VISTA HI DR EL JEBEL AREA, 0 Value Summary Value By:Market Override Land (1)$250,000 N/A Total $250,000 $250,000 Legal Description Subdivision: MOUNTAIN MEADOW RANCH FIL 2 Lot: 32 BK-0289 PG-0266 MAP 08-03-79 Sale Data Doc. #Sale Date Deed Type Validity Verified Sale Price Ratio Adj. Price Ratio Time Adj. Price Ratio 202105778 03/12/2021 WD QV Y $380,000 65.79 $380,000 65.79 $380,000 65.79 04/06/1998 WD UV Y $215,000 N/A $215,000 N/A $215,000 N/A Land Occurrence 1 Abstract Code 0100 - VACANT RES LAND Percentage 100.0 Use Code 1000 - RESIDENTIAL Neighborhood 1010.2 - MOUNTAIN MEMORIES Land Code 9056 - MOUNTAIN MEADOWS Super Neighborhood 900 - BASALT / EL JEBEL AREA Size 5.06 SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT Land L 1 Total 1.00 Value Rate Rate Rate Rate $250,000 250,000.00 Property Record Card Eagle A#: R023841 P#: 239134101001 As of: 09/03/2021 Page 1 of 2 Abstract Summary Code Classification Actual Value Taxable Value Actual Override Taxable Override 0100 VACANT RES LAND $250,000 $72,500 NA NA Total $250,000 $72,500 NA NA Property Record Card Eagle A#: R023841 P#: 239134101001 As of: 09/03/2021 Page 2 of 2 • Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction • Installs in min- utes inside new or existing tanks; extendible tee handle for easy removal • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion-proof construction, to ensure long life • Lifetime warranty Residential Biotube® Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. Standard Features & Benefits • Alarm available, to signal the need for cleaning • Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time • Custom and commercial sizes available Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes’ entire surface for filtering. Particles larger than the Biotube’s mesh are prevented from leaving the tank. Optional Features & Benefits Biotube Filtering Process 8-in. (200-mm) Base Inlet Filter 4-in. (100-mm) Insert Filter 4-in. (100-mm) Biotube Jr. (4-in. Biotube cartridge avail- able separately as Insert Filter) Orenco’s superior effluent filters resist clogging better than all other brands. Our stan- dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at half the size of our standard model, has more filtering capacity than the full-sized filters sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter is ideal. And for low-profile tanks, there’s the Base Inlet Filter. * Covered by patent numbers 5,492,635 and 4,439,323 4-in. (100-mm) Biotube Effluent Filter APS-FT-1 Rev. 3.4 © 11/10 Orenco Systems®, Inc. To Order Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on “Distributor Locator.” Nomenclatures Riser wall Tank wall Filter housing Extendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube® filter cartridge Solid base 4-in. Biotube Effluent Filter 4-in. Biotube Jr. 4-in. Biotube Filter (standard) 4-in. Biotube Jr. (includes cartridge and housing) Distributed By: 8-in. Biotube Filter (base inlet model) 4-in. Biotube Filter Insert (cartridge only) Junior series FT J0418 Biotube effluent filter series Filter diameter (inches) Cartridge height (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Options: Blank = no options M = flow modulation plate installed A = float bracket attached Blank = 1/8" filtration P = 1/16" filtration Insert FT i0418 Biotube effluent filter series Filter diameter (inches) Cartridge height (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee - For customized options (e.g., NC indicates North Carolina regions) - Blank = 1/8" filtration P = 1/16" filtration FT 04 Biotube effluent filter series Filter diameter (inches) Housing height: 36" and 44" are standard Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height: 28" and 36" are standard - Blank = 1/8" filtration P = 1/16" filtration W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe FT 2208 14 B Biotube effluent filter series Housing height: 22" standard Cartridge height: 14" standard Options: A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate* Base inlet model - Blank = 1/8" filtration P = 1/16" filtration Filter diameter (inches) 08 = 8" * Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT The Quick4® Plus Standard Chamber The Quick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36-inch-wide trench. Like the original line of Quick4 chambers, it offers advanced contouring capability with its Contour Swivel Connection™ which permits turns up to 15-degrees, right or left. It is also available in four-foot lengths to provide optimal installation flexibility. The Quick4 Plus All-in-One 12 Endcap, and the Quick4 Periscope are available with this chamber, providing increased flexibility in system configurations. Maximum Strength APPROVED in _____________________________________________ Quick4 Plus™ Series Quick4 Plus All-in-One 12 Endcap Benefits: • May be used at the end of chamber row for an inlet/outlet or can be installed mid-trench • Mid-trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows • Center-feed connection allows for easy installation of serial distribution systems • Pipe connection options include sides, ends or top Quick4 Plus All-in-One Periscope Benefits: • Allows for raised invert installations • 180° directional inletting • 12” raised invert is ideal for serial applications Certified by the International Association of Plumbing and Mechanical Officials (IAPMO) Quick4 Plus Standard Chamber Specifications Size 34”W x 53”L x 12”H (864 mm x 1346 mm x 305 mm) Effective Length 48” (1219 mm) Louver Height 8” (203 mm) Storage Capacity 47 gal (178 L) Invert Height 0.6” (15 mm), 5.3” (135 mm), 8.0” (203 mm), 12.7” (323 mm) Quick4 Plus Standard Chamber Benefits: • Two center structural columns offer increased stability and superior strength • Advanced contouring connections • Latching mechanism allows for quick installation • Four-foot chamber lengths are easy to handle and install • Supports wheel loads of 16,000 lbs/axle with 12” of cover Contact Infiltrator Water Technologies’ Technical Services Department for assistance at 1-800-221-4436 4 Business Park Road P.O. Box 768 Old Saybrook, CT 06475 860-577-7000 • Fax 860-577-7001 1-800-221-4436 www.infiltratorwater.com U.S. Patents: 4,759,661; 5,017,041; 5,156,488; 5,336,017; 5,401,116; 5,401,459; 5,511,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending. Infiltrator, Equalizer, Quick4, and SideWinder are registered trademarks of Infiltrator Water Technologies. Infiltrator is a registered trademark in France. Infiltrator Water Technologies is a registered trademark in Mexico. Contour, MicroLeaching, PolyTuff, ChamberSpacer, MultiPort, PosiLock, QuickCut, QuickPlay, SnapLock and StraightLock are trademarks of Infiltrator Water Technologies. PolyLok is a trademark of PolyLok, Inc. TUF-TITE is a registered trademark of TUF-TITE, INC. Ultra-Rib is a trademark of IPEX Inc. © 2013 Infiltrator Water Technologies, LLC. All rights reserved. Printed in U.S.A.PLUS05 0713 Quick4 Plus™ Series INFILTRATOR WATER TECHNOLOGIES STANDARD LIMITED WARRANTY (a) The structural integrity of each chamber, endcap and other accessory manufactured by Infiltrator (“Units”), when installed and operated in a leachfield of an onsite septic system in accordance with Infiltrator’s instructions, is warranted to the original purchaser (“Holder”) against defective materials and workmanship for one year from the date that the septic permit is issued for the septic system containing the Units; provided, however, that if a septic permit is not required by applicable law, the warranty period will begin upon the date that installation of the septic system commences. To exercise its warranty rights, Holder must notify Infiltrator in writing at its Corporate Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. Infiltrator will supply replacement Units for Units determined by Infiltrator to be covered by this Limited Warranty. Infiltrator’s liability specifically excludes the cost of removal and/or installation of the Units. (b) THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE (c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than Infiltrator. The Limited Warranty does not extend to incidental, consequential, special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages, including loss of production and profits, labor and materials, overhead costs, or other losses or expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse, abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation instructions; failure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the system containing the Units; failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, improper grease disposal, or improper operation; or any other event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails to comply with all of the terms set forth in this Limited Warranty. Further, in no event shall Infiltrator be responsible for any loss or damage to the Holder, the Units, or any third party resulting from installation or shipment, or from any product liability claims of Holder or any third party. For this Limited Warranty to apply, the Units must be installed in accordance with all site conditions required by state and local codes; all other applicable laws; and Infiltrator’s installation instructions. (d) No representative of Infiltrator has the authority to change or extend this Limited Warranty. No warranty applies to any party other than the original Holder. The above represents the Standard Limited Warranty offered by Infiltrator. A limited number of states and counties have different warranty requirements. Any purchaser of Units should contact Infiltrator’s Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase, to obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units. Quick4 Plus Standard Chamber ___________________________________________________________________________________ Quick4 Plus All-in-One 12 Endcap ________________________________________________________________________________ Quick4 Plus All-in-One Periscope ________________________ EFFECTIVE LENGTH48" 12" 34" QUICK4 PLUS ALL-IN-ONE PERISCOPE (360° SWIVEL) 12.7" INVERT PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 33" 18" 8" INVERT 13" EFFECTIVE LENGTH48" 12" 34" QUICK4 PLUS ALL-IN-ONE PERISCOPE (360° SWIVEL) 12.7" INVERT PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 33" 18" 8" INVERT 13" FRONT VIEW SIDE VIEW EFFECTIVE LENGTH48" 12" 34" QUICK4 PLUS ALL-IN-ONE PERISCOPE (360° SWIVEL) 12.7" INVERT PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 33" 18" 8" INVERT 13" 6" 5"9" Property Information https://property.eaglecounty.us/assessor/taxweb/search.jsp 705 Vista Hi Drive 239134101001 5ac Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs INCOMPLETE APPLICATIONS MAY NOT BE ACCEPTED It is recommended that you apply for an OWTS Permit and Building Permit concurrently. State law requires the OWTS Permit to be issued prior to the Building Permit. OWTS Permits expire after 120 days without an active building permit. Physical Address * Tax Parcel Number:* Lot Size: Residential/Single Family Residential/ Multi Family Commercial/Industrial Other: 4 Private Well Public Spring Surface N/A Ownership and Contact Information Building Type:* Number of Bedrooms (if residential), or type of use (if commercial)* Water Supply:* If Public, Name of Supplier David Hess 215-360-2969 1607 South Street, Philadelphia, PA 19146 phillydave@gmail.com David Hess 215-360-2969 phillydave@gmail.com Property Owner * Owner Phone Number * Owner Mailing Address Owner Email Address * Applicant/Contact Person:* Applicant Phone Number * Applicant Email Address * Licensed Systems Contractor Only License d Systems Contractors approved by Eagle County are authorized to perform work on OWTS in Eagle County. A list of Licensed Systems Contractors is available on the website: https://drive.google.com/file/d/1avu8QVUe cGCiUTYK3FE3JiVKBO5AlLca/view?usp=sharing To be Selected prior to star t 215-360-2969 phillydave@gmail.com Licensed System Contractor Name/ License #* Contractor Phone Number * Contractor Email * New Installation- $800 - New Builds of Residence or ADU Major Repair- $800 - Full OWTS or Soil Treatment Area (STA) repair or replacement Minor Repair- $400- Tank Replacement Only Alterations - Alteration- $400- Bedroom Additions/ADU Additions/Remodels to an existing permitted OWTS. Small Repair- $135 - Sewer pipe replacements, pump replacements. Like-for-like replacement of component in the original Professionally Engineered Design. Does not change the way the system was designed to function. may include connections to auxiliary structures that do not increase daily flow rate. Work that does not require a permit includes : adding risers and/or tank lid replacements, tee replacement, cleanout replacements, and very minor five feet or less of straight sewer pipe replacement where the contractor will submit scope of work and before and after photos to ECPHA New Installation- $800 - New Builds of Residence or ADU The State Law requires that the OWTS permit be issued before the building permit is issued. If your application is incomplete, it will delay the issuance of your OW TS permit, and the issuance of the building permit. Eagle County Board of Health declares that its general policy is to require the use of public sewer systems where and whenever feasible and to limit the installation of OWTS only to areas that are not feasible for connection to public sewer. Eagle County will not issue an OWTS permit where the structure to be served is within the applicable Water and Sanitation District that provides public sewer, unless the public ser vice provider is not willing to serve the structure, and authorizes the use of an OWTS. ALL OWTS IN EAGLE COUNTY MUST BE DESIGNED BY A COLORADO REGISTERED PROFESSIONAL ENGINEER. https://www.eaglecounty.us/environmentalheal th/septicsystems OWTS Permit Application is for:* Romeo A Baylosis 970-309-5259 carla.ostberg@gmail.com All of the Following Must be Summitted to be Considered a Complete Application: Electronically (preferred) to environment@eaglecounty.us By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County Office, Community Development Depar tment 500 Broadway in Eagle Dropped off at Eagle County Office, 20 Eagle County Drive in El Jebel Professional Engineer Name:* Engineer Phone Number:* Engineer Email:* Satisfactory design with site plan and soil profile results from a Colorado Registered Professional Engineer will be submitted * Online (2.5% convenience fee) https://client.pointandpay.net/web/eaglecoenvhealth By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County Office, Community Development Depar tment 500 Broadway in Eagle Dropped off at Eagle County Office, 20 Eagle County Drive in El Jebel The State Law requires that the OWTS permit be issued before the building permit is issued. Incomplete application, designs, will delay the issuance of the OWTS permit, and the issuance of the building permit/ An OWTS permit must be issued to the Licensed Systems Contractor prior to any installation, repair, or alteration work is performed. The contracted Licensed Systems Contractor must receive the permit from ECEH before the OWTS is installed. Completing this application does not constitute a permit. Eagle County’s review and approval of the Engineer’s design is required before a permit will be issued. Major Repair- $800 Full Replacement of the System or Tank and/or Soil Treatment Area (STA) repair or replacement. Tank Only Replacement is considered a Minor Repair. Environmental Health Prioritizes the Review of Repair Applications and Designs “Repair” means restoration of functionality and/or treatment by reconstruction, relocation, or replacement of an on-site wastewater treatment system or any component thereof in order to allow the system to function as intended. The $800 Permit Fee will submitted * I agree and understand that:* Emergency Use Permit May Be Required Concurrently with the issuance of a repair permit, the ECPHA may issue an emergency use permit authorizing continued use of a malfunctioning system on an emergency basis for a period not to exceed the period stated in the repair permit. Such an emergency us e permit may be extended, for good cause shown, in the event repairs may not be completed in the period state d in t he repair permit through no fault of the owner or occupant and only if the owner or occupant will continue to make repairs to the system. Malfunctioning. The OWTS or component within is not performing as designed, but not failing Failing. Sewage is leaking on the gound, into the ground untreated. Sewage is backing up into the house. Effluent is ponding, daylighting, or being disposed of without secondary treatment from a STA. Other:New install N/A ALL OWTS IN EAGLE COUNTY MUST BE DESIGNED BY A COLORADO REGISTERED PROFESSIONAL ENGINEER. https://www.eaglecounty.us/environmentalheal th/septicsystems Romeo A Baylosis 970-309-5259 The system is * If the system is failing please describe any emergency use steps being taken. Professional Engineer Name:* Engineer Phone Number:* carla.ostberg@gmail.com All of the Following Must be Summitted to be Considered a Complete Application: Electronically (preferred) to environment@eaglecounty.us By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County Office, Community Development Depar tment 500 Broadway in Eagle Dropped off at Eagle County Office, 20 Eagle County Drive in El Jebel Online (2.5% convenience fee) https://client.pointandpay.net/web/eaglecoenvhealth By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County Office, Community Development Depar tment 500 Broadway in Eagle Dropped off at Eagle County Office, 20 Eagle County Drive in El Jebel Engineer Email:* Satisfactory design with site plan and soil profile results from a Colorado Registered Professional Engineer will be submitted * The $800 Permit Fee will submitted * The State Law requires that the OWTS permit be issued before the building permit is issued. Incomplete application, designs, will delay the issuance of the OWTS permit, and the issuance of the building permit/ An OWTS permit must be issued to the Licensed Systems Contractor prior to any installation, repair, or alteration work is performed. The contracted Licensed Systems Contractor must receive the permit from ECEH before the OWTS is installed. Completing this application does not constitute a permit. Eagle County’s review and approval of the Engineer’s design is required before a permit will be issued. Minor Repair- $400- Tank Replacement Only “Repair” means restoration of functionality and/or treatment by reconstruction, relocation, or replacement of an on-site wastewater treatment system or any component thereof in order to allow the system to function as intended. Please note: repairs or replacement of the Soil Treatment Area are considered a Major Repair, other components may qualify for a small repair permit Emergency Use Permit May Be Required Concurrently with the issuance of a repair permit, the ECPHA may issue an emergency use permit authorizing continued use of a malfunctioning system on an emergency basis for a period not to exceed the period stated in the repair permit. Such an emergency us e permit may be extended, for good cause shown, in the event repairs may not be completed in the period state d in t he repair permit through no fault of the owner or occupant and only if the owner or occupant will continue to make repairs to the system. Malfunctioning. The tank or component within is not performing as designed, but not failing Failing. Sewage is leaking on the ground, into the ground untreated. Sewage is backing up into the house. Tank is not water-tight. Other:New Install I agree and understand that:* The tank is * ALL OWTS IN EAGLE COUNTY MUST BE DESIGNED BY A COLORADO REGISTERED PROFESSIONAL ENGINEER. https://www.eaglecounty.us/environmentalheal th/septicsystems Romeo A Baylosis 970-309-5259 carla.ostberg@gmail.com All of the Following Must be Summitted to be Considered a Complete Application: If the system is failing please describe any emergency use steps being taken. Professional Engineer Name:* Engineer Phone Number:* Engineer Email:* Electronically (preferred) to environment@eaglecounty.us By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County Office, Community Development Depar tment 500 Broadway in Eagle Dropped off at Eagle County Office, 20 Eagle County Drive in El Jebel Online (2.5% convenience fee) https://client.pointandpay.net/web/eaglecoenvhealth By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County Office, Community Development Depar tment 500 Broadway in Eagle Dropped off at Eagle County Office, 20 Eagle County Drive in El Jebel An OWTS permit must be issued to the Licensed Systems Contractor prior to any installation, repair, or alteration work is performed. The contracted Licensed Systems Contractor must receive the permit from ECEH before the OWTS is installed. Completing this application does not constitute a permit. Eagle County’s review and approval of the Engineer’s design is required before a permit will be issued. Alteration- $400 Bedroom Additions/ADU Additions/Remodels to an existing permitted OW TS. State Law requires that the OWTS permit be issued before the building permit is issued. If your application is incomplete, it will delay the issuance of your OW TS permit, and the issuance of the building permit. Satisfactory design with site plan from a Colorado Registered Professional Engineer will be submitted: * The $400 Permit Fee will submitted * I agree and understand that:* New Install ALL OWTS IN EAGLE COUNTY MUST BE DESIGNED BY A COLORADO REGISTERED PROFESSIONAL ENGINEER. https://www.eaglecounty.us/environmentalheal th/septicsystems Romeo A Baylosis 970-309-5259 carla.ostberg@gmail.com All of the Following Must be Summitted to be Considered a Complete Application: Existing OWTS Permit Number of Alteration:* Professional Engineer Name:* Engineer Phone Number:* Engineer Email:* Electronically (preferred) to environment@eaglecounty.us By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County Office, Community Development Depar tment 500 Broadway in Eagle Dropped off at Eagle County Office, 20 Eagle County Drive in El Jebel Online (2.5% convenience fee) https://client.pointandpay.net/web/eaglecoenvhealth By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County Office, Community Development Depar tment 500 Broadway in Eagle Dropped off at Eagle County Office, 20 Eagle County Drive in El Jebel The State Law requires that the OWTS permit be issued before the building permit is issued. Incomplete application, designs, will delay the issuance of the OWTS permit, and the issuance of the building permit/ An OWTS permit must be issued to the Licensed Systems Contractor prior to any installation, repair, or alteration work is performed. The contracted Licensed Systems Contractor must receive the permit from ECEH before the OWTS is installed. Completing this application does not constitute a permit. Eagle County’s review and approval of the Engineer’s design is required before a permit will be issued. Small Repair- $135 Sewer pipe replacements, pump replacements. Like-for-like replacement of component in the original Professionally Engineered Design. Does not change the way the system was designed to function. May include tanks. May include Satisfactory evaluation of existing design and proposed changes required with site plan and soil profile results from a Colorado Registered Professional Engineer will be submitted * The $400 Permit Fee will submitted I agree and understand that:* connections to auxiliary structures that do not increase daily flow rate. All repairs and connections must be completed by a licensed Eagle County OWTS Contractor. State Law requires that the OWTS permit be issued before the building permit is issued. If your application is incomplete, it will delay the issuance of your OW TS permit, and the issuance of the building permit. New Install New Install All of the Following Must be Summitted to be Considered a Complete Application: Online (2.5% convenience fee) https://client.pointandpay.net/web/eaglecoenvhealth By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County Office, Community Development Depar tment 500 Broadway in Eagle Dropped off at Eagle County Office, 20 Eagle County Drive in El Jebel Existing OWTS Permit Number:* Describe the repair work to be done:* The $135 Permit Fee will submitted * The State Law requires that the OWTS permit be issued before the building permit is issued. Incomplete application, designs, will delay the issuance of the OWTS permit, and the issuance of the building permit. It is best to submit the building permit to Community Development concurrently with this permit as most building permits have longer review times. An OWTS permit must be issued to the Licensed Systems Contractor prior to any installation, repair, or alteration work is performed. The contracted Licensed Systems Contractor must receive the permit from ECEH before the OWTS is installed. Completing this application does not constitute a permit. Eagle County’s review and approval of the work and existing PE design is required before a permit will be issued. Work that does not require a permit May Include: adding risers and/or tank lid replacements, tee replacement, cleanout replacements, and very minor five feet or less of straight sewer pipe replacement where the contractor will submit scope of work and before and after photos to ECPHA All work on a OWTS must be completed by a licensed Eagle County OWTS Contractor. N/A New Install N/A New Install I agree and understand that:* Existing OWTS Permit Number: (if not known please state so)* Describe the repair work to be done:* Photos of before and after will be submitted to Eagle County Environmental Health environment@eaglecounty.us Only an Eagle County Licensed Systems Contractor must perform work on an OWTS. Any additional work may require a permit and will be submitted for review to Eagle County EH This form was created inside of Eagle County Government. I agree and understand that:*  Forms Inspection Result Eagle County, Colorado P.O. Box 179 500 Broadway Eagle, CO Phone: (970) 328-8730 Fax: (970) 328-7185 IVR Phone: 1-866-701-3307 Inspection Number: INSP-524432-2023 Permit Number: OWTS-024628-2022 Inspection Date: 04/01/2025 Inspector: Lewandowski, Claire Permit Type: OWTS Permit Inspection Type: OWTS Final Inspection Work Classification: NewOwner:Aspen Vista Development LLC Job Address:705 VISTA HI DR IVR Pin Number:196544 EL JEBEL AREA, CO Project:<NONE> Parcel Number:239134101001 Contractor:Phone: (970) 309-3057 / Cell: (970) 309-3057E&L Trucking & Excavation, INC. Inspection Status: Approved Inspection Notes Inspector Comments Added Item: Septic Tank 2023.08.08 Observed in conformance will plans and regulations. Risers will be added to grade and add length to effluent filter handle to be corrected. Added Item: Record Drawing 03.30.2025 - Received with PE Final Added Item: Record Photos 03.30.2025 - Received with PE Final Added Item: Site and Soil 2023.08.08 All setbacks and soils correspond to design and meet regulations Added Item: Final Certification Letter Received 03.30.2025 Added Item: General Plan 2023.08.08 Distribution box observed level and equipped with speed levelers. Water tight at grade access. Added Item: Soil Treatment Area (STA) 2023.08.08 Observed install to conformance with design and regulations. Added Item: Identification of Systems Contractor 2025.04.01 - E&L Trucking - OWTSPL-000205-2022 Tuesday, April 1, 2025 For more information visit: http://www.eaglecounty.us Page 1 of 2 Tuesday, April 1, 2025 For more information visit: http://www.eaglecounty.us Page 2 of 2 Claire Lewandowski <claire.lewandowski@eaglecounty.us> OWTS Permit Application attachments - 705 Vista Hi Drive, Carbondale, CO 2 messages David H <phillydave@gmail.com>Tue, Jun 21, 2022 at 4:24 PM To: environment@eaglecounty.us Cc: Carla Ostberg <carla.ostberg@gmail.com> To: Eagle County Environmental Health Please see the attached documents accompanying the new single family residential OWTS permit application that was submitted online today. I submitted an online application using the provided google form today. Please note that the form required that I complete info for new installation, major repairs, and minor repairs. I completed redundant info as required by the electronic form despite this application being for a new install only. I hope that this did not cause any issues for you. I completed an online payment of the $800 fee plus a $20 online convenience fee. Confirmation Number: 116304551 Please let me know if you have any questions or require any additional info. Thanks, David Hess 215-360-2969 2 attachments 20210819 C1643 OWTS Design Packet 8 19 21.pdf 3624K 20210819 C1643 Component Specifications 8 19 21.pdf 4541K Danielle Salinsky <danielle.salinsky@eaglecounty.us>Tue, Jun 21, 2022 at 4:26 PM To: David H <phillydave@gmail.com> Cc: environment@eaglecounty.us, Carla Ostberg <carla.ostberg@gmail.com> Received, thank you. We will get this in our queue for review. Danielle [Quoted text hidden] -- Danielle Salinsky, M.P.H., M.S. Environmental Health Specialist I Eagle County Public Health and Environment Office: (970) 328-8755 Direct: (970) 471-6481 danielle.salinsky@eaglecounty.us