HomeMy WebLinkAbout1120 Diamond Star Rd - 193925204026 (2)PARCEL 14 37.04 ACRES 97.5' WELL PROPANE TANK HEADS WATER FEATURE PATIO PAVER WALKS LIGHT (TYP.) E PAD ELECTRIC TRANSFORMER PHONE PEDESTAL CENTERLINE SWALE PAVER WALK PAD AIR CONDITIONER 1120 TIE TO SOUTHERLY ANGLE PO INT PARCEL 141 £   :     TIE TO SOUTHWEST ANGLE POINT PARCEL 141£ (ELECTRIC METER WATER FEATURE 64.0 62.5 62.3 65.0 65.4 66.5 66.1 67.3 67.1 67.6 69.0 68.5 69.5 71.2 71.3 72.8 75.1 75.9 71.6 69.8 67.0 64.7 64.3 64.7 64.6 65.8 65.4 64.8 64.6 64.5 65.1 64.764.6 64.2 64.6 63.8 63.7 63.8 63.9 64.3 64.6 64.5 64.4 63.9 62.9 63.6 SPRINKLER VALVE CONCRETE DRIVE GRAVEL DRIVE GRAVEL VIEW- R E D C A N Y O N C LI F F S VIEW- SOUTH VALLEYVIEW POINT GARAGE SLAB ELEV=6765.1' SHED WOOD FRAME TWO STORY 4.0' 1 . 2 ' 12.3' 3 .7 ' 3.4' 27.3'2. 7 '51 . 0 ' 27.2' 16.4' 3 .1 ' 2.2'30 . 0 ' 2 0 . 2 ' 15.1' INVERT OUT 6" PVC INVERT IN 6" PVC PAD 97 1/2' RADIUS "HOMESITE" AS DEFINED IN THE DECLARATION AIR CONDITIONER PAVER WALKS CENTERLINE SWALE EXISTING MAIN HOUSE EXISTING BARN SHED 997 S.F. 21'-3"47'-0 "PROPOSED SHED 997 S.F. CLEANOUT CLEANOUT CLEANOUT EXISTING CLEANOUT EXISTING 2,000 GALLON SEPTIC TANK EXISTING GRAVITY EFFLUENT LINE TO SOIL TREATMENT AREA EXISTING SEWER LIN E PROPOSED SEWER LINE FROM SHED DOUBLE ENCASE SEWER LINE WITHIN 50 FEET OF WELL. SEE REPORT FOR DETAILS. 415 156A SITE PLAN FIGURE 1LOT 14, DIAMOND STAR RANCH APPROXIMATE SCALE: 1 INCH = 30 FEET sheet no. date: project: revisions: 0514piper / architecture, ltd.box 5560 avon, colorado 81620970-949-7074 dpiper@vail.netFINCHEM SHEDLOT 14, DIAMOND STAR RANCH EAGLE COUNTY COLORADO44'-0"21'-3"19'-8" 8"16'-0"3'-2 1/2" 44'-0" 23'-7 1/2"10'-0"11'-3"8"4"8"5'-1"4'-10"4"4"19'-9"8"4"4'-0"4'-0"1'-3"20'-0"17'-2 1/2"6"4'-4"5'-4"4"6"6"15'-3"8"4"4.10.15 permit EXERCISE AREA GOLF SIMULATOR MECH. top of conc. slab 100-0 f.d. @ 99-11 FLOOR PLAN 1/4" = 1' note: area in square feet = 935 s.f. shaded area of mech. = 85 s.f. net area = 850 s.f. roof edge 2-0A-2.14"A-4.1 A-4.1 PLAN NORTH Work Classification:Alteration 400 PONTE VEDRA BLVD PONTE VEDRA FL 32080-2817 AddressOwner Information Permit Status:Active Project Address 193925204026 Permit Type:OWTS Permit Permit NO.OWTS-6-15-12819 Expires:10/17/2015Issue Date:6/19/2015 Parcel No. 1120 DIAMOND STAR RD Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: Cell: Inspection For Inspections call:(970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)945-7988HP GEOTECH Contractor(s)Phone Primary ContractorLicense Number ARENA EXCAVATING AND DEVELOPMENT (970)328-3477 Yes34-15 FINCHEM, TIMOTHY WILLIAM & HOLLY BACHAND FINCHEM, TIMOTHY Permitted Construction / Details: Connect the plumbing from the half bathroom located in the shed via the installation of a new sewer line as detailed in the HP Geotech design report dated, stamped and signed May21, 2015. The new sewer line will connect to the existing sewer originating from the residence with a downstream wye connection just ahead of the 2,000 gallon septic tank and must also be encased as detailed in the design report. This OWTS Permit is an alteration to the septic system original permitted under ISDS Permit #2276-03. Contact the design engineer to conduct all inspections necessary to certify the system and to prepare the as-built drawings. System certification along with the as-built drawings and photos are required to be submitted to and approved by Eagle County Environmental Health prior to the use of the half bathroom or occupancy of the shed. Issued by: Environmental Health Department, Eagle County, CO June 19, 2015 Date Customer Copy Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101,et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED (:~I)tech HEPWORTH -PAWLAK GEOTECHNICAL October 28, 2015 Beck Building Company Attn: Graham Strickland POBox 7796 Avon, Colorado 81620 Ht'l'WlHth ·P,l\d.lk L/c,ltt'chIllC;11. 11K . r. 0. Drawer It'H7 Siln~nh\)mt', C~II\lr .I~I\\ tk'49:r Plwnt,: 970-4N~·1l)tN EIX: ~70·46R·5891 emai l: hrgl:"l)4@ h pgel)tech.Llll11 Job No. 415 156A Subject: As-Built Evaluation of On site Wastewater Treatment System Connection, Existing Residence, Lot 14, Diamond Star Ranch, 1120 Diamond Star Road, Eagle County, Colorado Dear Mr. Strickland: Hepworth-Pawlak Geotechnical, Inc. has observed the repair of the Onsite Wastewater Treatment System (OWTS) connection from the proposed shed to the existing OWTS located at 1120 Diamond Star Road in Eagle County, Colorado. We previously prepared an As-Built Evaluation of the OWTS in our report dated October 1,2015. The October 1st report showed a Femco fitting that was used to connect the sewer line from the residence to the new sewer line from the shed structure. The fernco fitting is considered unsuitable for the connection. The Fernco fitting was removed and replaced with an expandable glued repair fitting as shown in the photograph below. '. ~<::~~ -. Glenwood Springs 970-945-7988 • Parker 303-841-7119 • Colorado Sp ri ngs 719-633 -556 2 Beck Building Company October 28, 2015 Page 2 Based on our observations ofthe repair, the sewer line is now suitable for use. Please feel free to contact us if you have any questions regarding this letter. Sincerely, HEPWORTH -PAWLAK GEOTECHNICAL, INC. Jason A. Deem Project Geologist Chad M. Bringle, P.E. Project Engineer Job No. 415 156A ~tech October 30, 2015 Mr. Finchem c/o Graham Strickland graham@beckbuilds.com RE: Final approval of septic permit OWTS-6-15-12819; Tax parcel #193925204026; Property location: 1120 Diamond Star Road, Eagle area Mr. Finchem: This letter is to inform you that the above-referenced septic permit has been inspected and finalized. This permit was approved for the addition of a pool house/workout area to be connected to the existing OWTS system. Additional information about the maintenance your septic system needs as well as information about private wells can be accessed through web site links provided on the Environmental Health Department’s home page at http://www.eaglecounty.us/envHealth/ Be aware that changes in the use of your property or alterations of your building may require commensurate changes to, or relocation of, your septic system. Landscape features, trees with tap roots, irrigation systems and parking areas above the drain field can cause premature system failure. It is equally important that you notice and immediately repair dripping faucets and hissing toilets as this will certainly cause the system to fail. By following a few simple guidelines, like avoiding grease or other additives down the drain and making sure your septic tank is on a pumping schedule, your system has been designed to last for many years. If you have any questions regarding this information, please contact us at (970) 328-8755 and reference the OWTS septic permit number. Sincerely, Terri Vroman Administrative Technician IV cc: OWTS electronic permit folder Energov electronic file Graham Strickland – Beck & Assoc. Jason Deem – HP Geotech DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eaglecounty.us RAYMOND P. MERRY, REHS Director