HomeMy WebLinkAbout4001 Nolan Creek Rd - 219723400005Work Classification: NewPermit PO BOX 186 EAGLE CO 81631-0186 Address Owner Information Permit Status: Active Project Address 219723400003 Permit Type: OWTS Permit Permit NO. OWTS-4-16-14512 Expires: 12/7/2016 Issue Date: 8/9/2016 Parcel No. 4001 NOLAN CREEK RD Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR OWTS Final Inspection 095 PhoneEngineer(s) (970)471-2121BROCK CONSULTING, LLC Contractor(s)Phone Primary ContractorLicense Number BROCK CONSULTING LLC (970)328-2123 Yes21-16 HASBROUCK, BRUCE W., JR & SUSAN C. HASBROUCK, BRUCE W., JR & Permitted Construction / Details: Install the OWTS exactly as depicted on the Brock Consulting, LLC design stamped, signed and dated by Vern L. Brock, PE on June 6, 2016. System is designed to serve a two bedroom cabin. System consists of a 1,000 gallon Valley Precast two compartment septic tank with Bio effluent screen on the outlet tee; and 263 square feet of soil treatment area (prior to applying the 30% adjustment for using chambers) via the installation of 22 Infiltrator Quick 4 Plus Standard chambers atop a two foot layer of concrete sand arranged in two shallow, serially-connected trenches with 11 chambers in each trench. Verification of the LTAR must be demonstrated by observing an additional profile pit during excavation, the location of which must be shown on the as-built drawings. Any changes to the design requires written approval of Eagle County Environmental Health. The design engineer must conduct all inspections necessary to certify the system and prepare the as-built drawings. System certification along with as-built drawings and photos are required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. Issued by: Environmental Health Department, Eagle County, CO August 10, 2016 Date Customer Copy Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED Work Classification: NewPermit PO BOX 186 EAGLE CO 81631-0186 Address Owner Information Permit Status: Active Project Address 219723400003 Permit Type: OWTS Permit Permit NO. OWTS-4-16-14512 Expires: 12/7/2016 Issue Date: 8/9/2016 Parcel No. 4001 NOLAN CREEK RD Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR OWTS Final Inspection 095 PhoneEngineer(s) (970)471-2121BROCK CONSULTING, LLC Contractor(s)Phone Primary ContractorLicense Number BROCK CONSULTING LLC (970)328-2123 Yes21-16 HASBROUCK, BRUCE W., JR & SUSAN C. HASBROUCK, BRUCE W., JR & Permitted Construction / Details: Install the OWTS exactly as depicted on the Brock Consulting, LLC design stamped, signed and dated by Vern L. Brock, PE on June 6, 2016. System is designed to serve a two bedroom cabin. System consists of a 1,000 gallon Valley Precast two compartment septic tank with Bio effluent screen on the outlet tee; and 263 square feet of soil treatment area (prior to applying the 30% adjustment for using chambers) via the installation of 22 Infiltrator Quick 4 Plus Standard chambers atop a two foot layer of concrete sand arranged in two shallow, serially-connected trenches with 11 chambers in each trench. Verification of the LTAR must be demonstrated by observing an additional profile pit during excavation, the location of which must be shown on the as-built drawings. Any changes to the design requires written approval of Eagle County Environmental Health. The design engineer must conduct all inspections necessary to certify the system and prepare the as-built drawings. System certification along with as-built drawings and photos are required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. Office Copy August 10, 2016 Issued by: Environmental Health Department, Eagle County, CO Date Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED September 25, 2019 Mr. Bruce Hasbrouck bhasbrouck@centurytel.net Po Box 186 Eagle, CO 81631 RE: Final approval of the: Septic System Installation, OWTS-4-16-14512 Property location: 4001 Nolan Creek Road, Fulford – Parcel # 219723400003 Mr. Hasbrouck: This letter is to inform you that the above-referenced permit has been inspected and finalized. This OWTS permit was approved and sized to serve a two (2) bedroom cabin residence. Additional information about the maintenance your septic system needs can be accessed through our website links, provided on the Environmental Health Department’s septic system resource page. Be aware that changes in the use of your property or alterations of your building may require commensurate changes to, or relocation of, your septic system. Landscape features, trees with tap roots, irrigation systems and parking areas above the soil treatment area can cause premature system failure. It is equally important that you notice and immediately repair dripping faucets and hissing toilets as this will certainly cause the system to fail. If you have any questions regarding this information, please contact us at (970) 328-8755 and reference the OWTS septic permit number. Best Regards, Claire Lewandowski Environmental Health Specialist III Attachments: Certification Letter and Design – Septic System Flyer – Final Letter PUBLIC HEALTH & ENVIRONMENT (970) 328-8755 FAX: (970) 328-8788 Environment@eaglecounty.us SEPTIC RECORD DRAWING N GRAPHIC SCALE: 1"=10'