HomeMy WebLinkAbout407 McLaughlin Ln - 247106306012INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway X Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2261-03 BUILDING PERMIT NO. 14871 OWNER: BRAD LUNDGREN PHONE: 815-397-4686 MAILING ADDRESS: 991 S PERRYVILLE RD., ROCKFORD, IL 61108 APPLICANT: SAME PHONE: SYSTEM LOCATION: 407 McLAUGHLIN RD., BASALT, CO TAX PARCEL NO. 2471-063-06-012 LICENSED INSTALLER: WILDCAT EXCAVATING, CO., DON BARR LICENSE NO. 65-03 PHONE: 970-3903190 DESIGN ENGINEER: CHURCH AND ASSOCIATES, TIM PETZ PHONE NO. 303-463-9317 INSTALLATION GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 3 BEDROOM RESIDENCE 1000 GALLON SEPTIC TANK, 1023 SQUARE FEET OF ABSORPTION AREA CREDIT VIA 33 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN DATED APRIL 10, 2003. SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN WITH A CLEAN -OUT BETWEEN THE TANK AND THE HOUSE, AND INSPECTION PORTALS IN EACH TRENCH. RAKE ALL TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS, AND DO NOT INSTALL IN WET WEATHER. BE SURE TO MAINTAIN ALL APPLICABLE SET BACK REQUIRE- MENTS. CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER FOR THE FINAL IN- SPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION, OR WITH ANY QUESTIONS REGARDING THE INSTALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROVAL: LAURA FAWCETT DATE: JUNE 23, 2003 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1023 SQUARE FEET (VIA 33 INFILTRATOR UNITS AS PER DESIGN ) INSTALLED CONCRETE SEPTIC TANK: 1000 GALLONS IS LOCATED 206 DEGREES AND 23 FEET 6 INCHES FROM THE CLEANOUT ON THE SOUTH SIDE OF THE HOUSE. COMMENTS: THE FINAL INSPECTION WAS DONE BY LAURA FAWCETT OF EAGLE COUNTY ENVIRONMENTAL HEALTH ON JULY 1, 2003, AND THE DESIGN ENGINEER ON JUNE 25 2003. THIS SYSTEM IS LARGE ENOUGH TO ACCOMMODATE A THREE BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE - INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVALdDATE: SEPTEMBER 9, 2003 INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2261-03 BUILDING PERMIT NO. 14871 OWNER: BRAD LUNDGREN PHONE: 815-397-4686 MAILING ADDRESS: 991 S PERRYVILLE RD., ROCKFORD, IL 61108 APPLICANT: SAME PHONE: SYSTEM LOCATION: 407 McLAUGHLIN RD., BASALT, CO TAX PARCEL NO. 2471-063-06-012 LICENSED INSTALLER: ASPEN EARTHMOVERS, TROY BUSTER LICENSE NO. 57-03 PHONE: 970-963-0377 DESIGN ENGINEER: CHURCH AND ASSOCIATES, TIM PETZ303-463-9317 PHONE NO. INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 3 BEDROOM RESIDENCE 1000 GALLON SEPTIC TANK,1023 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 33 INFILTRATOR UNITS PER DESIGN SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN DATED 4/10/03, WITH A CLEAN -OUT BETWEEN THE TANK AND THE HOUSE, AND INSPECTION PORTALS IN EACH TRENCH. RAKE ALL TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS, AND DO NOT INSTALL IN WET WEATHER. BE SURE TO MAINTAIN ALL APPLICABLE SET BACK RE- QUIREMENTS. CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER FOR THE FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION, OR WITH ANY QUESTIONS REGARDING THE INSTALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYS- TEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROVAL: DATE: MAY 14, 2003 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET (VIA ) INSTALLED TANK: GALLONS IS LOCATED DEGREES AND FEET INCHES FROM COMMENTS: ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL DATE: n=M_CU-CVU1 l V i CJF1 r RUN. CnULC t-UU111 1 CI`IV flr-rl 7 1 el.]COO 1 00 1 u 0 717 1 v_17013C1370 r. 1' J Incomplete Applications Will NOT Be Accepted (Site Plan MUST be attached) ISDS Permit #"' Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 816.31 Eagle (970)328-8755, Fax (970)328-0349, El Jebel (970)927-3823 * FEE SCHEDUL9 * APPLICATION PER $350.00 * THIS FEE INCLUDES THE ISDS PERMIT, SITE EVALUATION (PERCOLATION TEST, * SOIL PROFILE OBSERVATION) AND FINAL INSPECTION * ADDITIONAL FEES MAY BE CHARGED IF A REINSPECTION IS NECESSARY, OR A * PRE -CONSTRUCTION SITE VISIT OR CONSULTATION IS NEEDED * REINSPECTION FEE $47.00, PRE -CONSTRUCTION SITE VISIT FEE $85.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: �' qi FtF vQ.. R EOR> MAILING ADDRESS: APPLICANT/CONTACT PERSON: LICENSED SYSTEMS CONTRACTOR: COMPANY/DBA: ADDRESS: PHONE: CAS PHONE : (Kt5 PHONE: .. _31 QQo PERMIT APPLICATION IS FOR: ()() NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: La 3 Ram 91cRE-5 S;� b) vy52Whl &M & NO Tax Parcel Number: �'�% (20 Q(2Of Z1 Lot Size: Physical Address: �k7 Irk-_.tAa Lw RmAz, co ?Z6a BUILDING TYPE: (Check applicable category) 3 ()e) Residential/Single Family Number of Bedrooms ( ) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type *These systems require design by a Registered Professional Engineer TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surfac e OU Public Name of lie ! APPLICANT SIGNATURE: 07i- 07- 03 AMOUNT PAID: y RECEIPT # CHECK #: _ DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE:800-225-6136 www.eagle-county.com September 9, 2003 Brad Lundgren 991 S. Perryville Rd. Rockford, IL 61108 EAGLE COUNTY RAYMOND P. MERRY, REHS Director RE: Final of ISDS Permit #2261-03, Tax Parcel #2471-063-06-012. Property location: 407 McLaughlin Rd., Basalt, CO. Dear Mr. Lundgren: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Eagle County Environmental Health Department ENCL: Educational Brochure Final ISDS Permit cc: files, September 2003 Chrono file OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE:800-225-6136 www.eagle-county.com DATE: June 23, 2003 EAGLE COUNIY TO: Wildcat Excavating, CO., LLC FROM: Eagle County Department of Environmental Health RAYMOND P. MERRY, REHS Director RE: Individual Sewage Disposal System Permit 92261-03, Tax Parcel # 2471-063-06-012, Property Location: 407 McLaughlin Rd., Basalt, CO., Lundgren residence. Enclosed is your ISDS Permit #2261-03, and a copy of the engineer's design for this system. The permit is valid for 120 days or for the duration of your current building permit for this property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this Department. Systems designed by a Registered Professional Engineer must be certified by the engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer and views the installation. Please note that our ISDS Permit specifications are typically minimum requirements only and should be brought to the property owner's attention in case they may wish to install a system capable of handling larger wastewater flows. This permit does not indicate conformance with any other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact us at (970) 328-8755. cc: ISDS file # 2261-03 church & Associates, Tim Petz Chrono file May 2003 OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE:800-225-6136 www.eagle-county.com DATE: May 14, 2003 EAGLE COUNTY TO: Aspen Earthmoving, LLC FROM: Eagle County Department of Environmental Health RAYMOND P. MERRY, REHS Director RE: Individual Sewage Disposal System Permit #2261-03, Tax Parcel # 2471-063-06-012, Property Location: 407 McLaughlin Rd., Basalt, CO., Lundgren residence. Enclosed is your ISDS Permit #2261-03, and a copy of the engineer's design for this system. The permit is valid for 120 days or for the duration of your current building permit for this property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this Department. Systems designed by a Registered Professional Engineer must be certified by the engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer and views the installation. Please note that our ISDS Permit specifications are typically minimum requirements only and should be brought to the property owner's attention in case they may wish to install a.system capable of handling larger wastewater flows. This permit does not indicate conformance with any other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact us at (970) 328-8755. cc: ISDS file # 2261-03 church & Associates, Tim Petz Chrono file May 2003 OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 CHURCH & Associates. Inc. ENGINEERS & GEOLOGISTS August 28, 2003 John Muir Architects, Attn: Lane 201 Main Street, Suite 304 Carbondale, CO 81623 Subject: Revised Installation Observation, Proposed Lundgren Residence Lot 3, Ruedi Shores Eagle County, Colorado Job No. 15639W Mr. Muir, As requested, we observed the installation of the onsite wastewater system for the subject site on June 25, 2003. The system was designed under our Job No. 15639W, dated April 10, 2003. Eagle County requested more information because the previous installation observation, dated June 30, 2003, did not discuss the effluent inlet and serial overflow lines in adequate detail. The system includes the installation of a 1000-gallon, two -compartment, precast concrete septic tank with an effluent filter on the outlet, and three chamber -trenches with serial overflow distribution. The effluent inlet and serial lines to each trench were installed in the `top' of the gravelless chamber end plate. Each trench had 1 row of 11 chambers for a total of 33 chambers and of 1023 square feet of infiltrative area. An as -built drawing is included as Figure 1. The components of the OWS were installed in conformance with our plans and specifications. Sincerely, CHURCH & Associates, Inc. r - r' +�✓: ? • V Timothy R. Petz Project Manager EOC/trp 2 copies sent Reviewed by cs fig, ZVI Edward O. Church, Copy to Eagle County Department of Environmental Health, Attn: Laura Fawcett DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 www.geo-church.com 303.463.9317 Fax: 303.463.9321 Toll Free-1.877.248.3123 F'HUF'USEU HE61L)ENUE LOT 3, RUEDf SHORES SUBDIVISION, FILING NO. 1 SECTION 6, T8S, R8W EAGLE COUNTY, COLORADO I000-GALLON, TWO -COMPARTMENT PRECAST CONCRETE , SEPTIC TANK WITH AN EFFLUENT FILTER ` AT THE OUTLET PROPOSED 3-BEDROOM RESIDENCE 4" PVC SERIAL OVERFLOW LINE L14 L15---' AL3 CLEANOUT O \ — —L4 `ySdo L5 L6 L7 S- L8 L9 Soo/ 511.5 SQ. FT, OF INFILTRATIVE AREA IN 3 GRAVELLESS CHAMBER -TRENCHES. EACH TRENCH MUST HAS ONE ROW OF II CHAMBERS EACH FOR A TOTAL OF 33 CHAMBERS. L!: N 86' W, I' L6: S 4° W, 4' LIi: S 4° W, P L2: N 86° W, I' L7: S 28° W, 6.5' L12: S 49° W, I' L3:S2°E,I' L8:S1°E,IT LI3:S80'W,5' L4:S43*W,P L9:S41'E,2' L 14: S 13' E, 3. 5' L5: S 43* E, 4.5' L10: S 41' E, I' LI5: S 58° E, I' AS -BUILT DIAGRAM 4" PVC SEWER LINE 12' OBSERVATION/ VENT PIPE LIO LII L12 JOB NO. 15639W FIGURE 1 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS June 30, 2003 John Muir Architects, Attn: Lane 201 Main Street, Suite 304 Carbondale, CO 81623 Subject: Installation Observation, Proposed Lundgren Residence Lot 3, Ruedi Shores Eagle County, Colorado Job No. 15639W Gentleman; RECEIVED JUL 8 2UU3 ENVIRONMEN SAL HEALTH DEPARTMENT As requested, we observed the installation of the onsite wastewater system for the subject site on June 25, 2003. The system was designed- under- our Job No. 15639W, dated April 10; 2003. The system includes the installation of a 1000-gallon, two -compartment, precast concrete septic tank with an effluent filter on the outlet, and three chamber -trenches with serial overflow distribution. Each trench had 1 row of 11 chambers for a total of 33 chambers and of 1023 square feet of infiltrative area. An as -built drawing is included as Figure 1. The components of the OWS were installed in conformance with our plans and specifications. Sincerely, CHURCH & Associates, Inc. ��✓lam Timothy R. Petz Project Manager TRP/erb Reviewed by Joseph C. Kordziel, P.E. 2 copies sent copy to Eagle County Department of Environmental Health, Attn: Ray Merry DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 303.463.9317 Fax: 303.463.9321 PROPOSED RESIDENCE LOT 3, RUED! SHORES SUBDIVISION, FILING NO. 1 SECTION 6, T8S, R8W EAGLE COUNTY, COLORADO 1000-GALLON, TWO -COMPARTMENT PRECAST CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER AT THE OUTLET 4" PVC SERIAL OVERFLOW LINE L14 L15 ---'.A L13 SCALE ill =20' PROPOSED 3-BEDROOM RESIDENCE L2 L3 O L4 O L5 - L6 L7 L8 L9 3 s. 4 511.5 SQ. FT. OF INFILTRATIVE AREA IN 3 GRAVELLESS CHAMBER -TRENCHES. EACH TRENCH MUST HAS ONE ROW OF II CHAMBERS EACH FOR A TOTAL OF 33 CHAMBERS. LI:N86'IN, V L5:S4°W,4' LII:S4°W,P L2: N 86' W, 1' L7: S 28' W, 6.5' L12: S 49° W, I' L3: S 2° E, I' L8: S 1° E, 3.5' L13: S 80' W, 5' L4:S43*W,I' L9:S41°E,2' L14:S13'E,3.5' L5: S 43' E, 4.5' L10: S 41' E, I' L15: S 58' E, I' Ll CLEANOUT 4" PVC SEWER LINE OBSERVATION/ VENT PIPE 10 11 12 AS -BUILT DIAGRAM JOB NO. 15639W FIGURE 1 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS April 10, 2003 John Muir Architects, Attn: Lane 201 Main Street, Suite 304 Carbondale, CO 81623 Subject: OWS Design, Proposed Lundgren Residence Lot 3, Ruedi Shores Eagle County, Colorado Job No. 15639W Gentlemen; As requested, we have designed an onsite wastewater system (OWS) for the proposed residence. H.P. Geotech performed the subsurface investigation, on August 28, 2002. SITE CONDITIONS The lot is located in a rural residential area in Eagle County, Colorado, where OWS are required. The proposed drain field area has a slope of 30% to 35% to the southwest and a thick cover of native grasses and sagebrush with sparse aspen and evergreen trees. An ofisite community well will serve the properly. PROPOSED CONSTRUCTION A three -bedroom residence is proposed at the location presented on Figures 1 and 2. The OWS was sized based on 3 bedrooms and 450 Gallons Per Day (GPD) using Eagle County Department of Environ- mental Health (ECDEH) loading of 75 gallons per day per person. The sewage loading with a peaking factor of 1.5 is 675 GPD. The loading includes washing machines and garbage grinders. SUBSURFACE CONDITIONS A subsurface investigation was performed HP Geotech by digging three percolation holes, 44 to 50 inches deep, and one profile pit at the locations indicated on Figure 1. Subsurface materials in the .profile pit consisted of 1 foot of topsoil, underlain by sandy, gravelly clay to 3 feet, underlain by silty, clayey gravel with cobbles and scattered boulders to the maximum depth explored of 9 feet. No ground water was encountered. Percolation tests indicate percolation rates of 24 to 30 minutes per inch (MPI). The average percolation rate is 28 MPI. Gradation test results indicate material consisting of 62% gravel, 14% sand, and 24% fines at the depth of the percolation test, which classifies as a sandy loam to loam. A sandy loam to loam has an LTAR of 0.6 gals/SF/day and a percolation rate of 16 to 30 NTL The design is based on a percolation rate of 28 MPI. Percolation data is presented in Appendix A. RECOMMENDATIONS The installation requires. a septic tank with an effluent filter and a three chamber -trenches at the locations presented on Figure 2. The OWS design is based on an average sewage load of 450 GPD and a percolation rate of 28 MPI. The installation must include one 1000-gallon, two -compartment, precast concrete septic DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 303.463.9317 Fax: 303.463.9321 OWS Design Job No. 15639W, 4/10/03 Page 2 tank with an effluent filter on the outlet and three chamber -trenches. Each trench must have 1 row of 11 chambers for a total of 33 chambers and 511.5 square feet of infiltrative area. A 30% reduction was taken for the use of chamber -trenches. Serial overflow lines are required to distribute effluent to the trenches. Vehicle movement over the drain field area during construction should be kept at a minimum to minimize compaction of the receiving soils. The bottom of the trenches should be scarified with a pick, shovel, or backhoe bucket teeth prior to the addition of chambers. The surface of the field should be seeded after installation of the fields. A native seed mix should be sown at the drain field to revegetate the surface. These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler system should be installed over the trenches. OPERATION AND MAINTENANCE The owner must realize an OWS is different from public sewer service, and must assume the responsibility for maintenance of the OWS. The system is relatively maintenance free, but the owner must have the septic tanks pumped. In the absence of a monitoring program, the septic tanks should be pumped and the effluent filter cleaned every two years. There are daily considerations, such as not putting plastic or other nonbiode- gradable material into the OWS. Water use must be monitored so toilets are not allowed to run when seals malfunction. To illustrate the point, a running toilet can consume in excess of 1000 GPD. A loading of 1000 GPD could flood and irreparably harm the OWS. The loading from the backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas should not be introduced to the OWS. LEWffATIONS An OWS design requires installation by a contractor who is experienced in its installation. Our investigation, layout, design and recommendations are based on data submitted. If subsurface conditions considerably different from those described in this report are encountered, we should be notified to evaluate the effect on the proposed OWS. If the health department makes modifications to this design, we should be contacted to evaluate the impact on the performance of the OWS. All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic tank construction, and other specifications, which are not depicted in our report, are to conform to the requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of the Eagle County ISDS regulations and requirements. If there are questions or if we can be of further service, please call. The project manager is Tim Petz. CHURCH & Associates o �a Edward O. Church, P E U EOC/trp/erb 3 copies sent via Priority Mail Appendix A — H.P. Geotech Subsoil Study for Foundation Design and Percolation Test PROPOSED RESIDENCE SCALE -LOT 3, RUEDI SHORES SUBDIVISION, FILING NO. 1 1"=40' SECTION 6, T8S, R8W EAGLE COUNTY, COLORADO 8/20 r,°"9y a 'k. }' 5. N1 I. N. ... 54 t",5yM1 dro. d'4 O':b, , ::' ; a" , °4,y,„ e�1h`':, `'+y •ni 1"5 iy5n 'y, +55 �.9 °r"',. ` h'+° `'3:.° `5,°, ,S,A"'•..;50-"5Y`''40 °i'. h.'�,pG, (�'J J Q °`"""w •ee 'yo-. ^a "",:fir+ ^y Y ! a, aY " y �'r.u,.+^". '." w V .. x V"y, 'k. °,. •'an " x•b, '1''4. 'S:t, "5t >„4 N1, a �:,x''y '°t" 15. 5j'q" 'b, ,aY' ° '5.,, b.. n1'. a'S •qh„� �(/� k `x1•T," .ti,d *""1°•:5r y 4 �p ti..:�, a �. �d°. 1:ip I�R�SED :y M Yu,^ "o-4:", h.,^ h,hA ry o ten° 4�^'� "' .ti ""�. °.. 1 ,:,^ —�EbR' 0 ( y�ary ��, V"`a:a qt:x '""'^ °„t". '''i, `'a, � "� i`•d v �* IbENCE .ry y t ," 3 k` a **4'5,,,:,'Se •� "'4 y VO �°1",kd�.'u: ��'}'"L. " ud� 4y�kw ��r1. e"'y't'•ha '":� "Y;1• ' v5^ h1 �1n .,�" o-'V,1 :W i `. 44 �4 u":4d. J�1yi, `. �: ., 6� "^x. tR ^y ndy "'`15,r "9y,,, 'Mr 1•`+„ �"a° 'td �'d a6hn 1k a �. �' 'A; 1, 1', r. •5 � 'nn `"hy "i5 4 rr! ^+ O1'V"�•.. x,rti c^wb °" °"'•h'.q ."5t .ytrk r '^.• 'irr `h 45'S� 'a,n� 5:" �°':, `4, 'Y, ""h` h*'"a,1+u :R r,1 +,,5. L 'y"k " .'Sa 'S, ".'":,A •1'°i }15° 1''.F w5 � ''' h d1'''eT °'st o- F 4• 4'45, 5,, .`a'h,t44 5jky a. 1' A 'k' S'" 5 1 >'d"" "1 V "•0nF Ni ( •'1 h, y` y4 �Y „5 "y'ti,' a r„"`',< o 'a �"""'.u� "'�` q��5•,. „� 't ty ": °'tn °'uP ( A'h': 9r •4 �"4u 'S. h" �,y �°rY ""L'ry `"9n 'M '•`" \ 5",i,� 5:. 'r5. "°1' ; p �'r�4.r � h, ,� a�^y aryy �"vr '"S.hL `4, `' "�"S 'h,,, ^,,� I��.°. 2 g''d�""d,,t "4� •''h'S* ,r'"^,,, " " 'a, "� 4,,5 v..:t„ 'Tr:1d '• tir k„^ r1•:r °5rb "yu� dr. •"t• �•,,,,M "'a, °"^. '" `°,t''w °y. 2i°''^v ". �r� ` '':, ,'i^ `ayd i"h, ^°5"d¢.. "ti. AryTML4.¢'^�n:,,,� r```.:Y `°x,,,,'`°dx,,,�°`,::t, ^`'�r, "'"• ,��' ,`�„ "° F�{:,Zd'FII'�� I�" .�5 ,,,� F 4,��,r'a., '°,, ,"I/y .,, .,°t'd,:, �"4,. •'� "*� e"2r„y'S"",.t L,4 '``r, °""� yy`"n, ",i"P— "ay " °urry` "•14 �1\� Y '',•• n'ti 0. ` Lair °,,m„w No.,w m" a. 4"'tu,tt '45t '"^,,,� � "M1a, Ya °•5,,, >'h ''M, 5° �j5`� �r. � h�''y �' . 455''e , / //'��'n°n „ ' r A ,"ih:, "'':54"• M yk;h .5r 4. ,t +u1j4h � , ° 1 12" REAR EASEMENT " EXISTING THE LOCATION OF EXISTING AND VENT �. ,a � PROPOSED IMPROVEMENTS SHOWN r's� PIPES HEREIN AND THE WELL AND/OR DRAIN ,°"'F (LOT 2) FIELD LOCATIONS STAKED AT THE,r SITE ARE NOT THE RESULT OF A 10' SIDE PROPERTY SURVEY. IMPROVEMENT EASEMENT LOCATIONS ARE APPROXIMATE. IT IS , THE PROPERTY OWNER'S✓ RESPONSIBILITY TO DEFINE PROPERTY BOUNDARIES AND ENSURE ALL ONSITE IMPROVEMENTS ARE LOCATED WITHIN ` 3r; THE PLATTED SITE AND OUT OF , INAPPROPRIATE EASEMENTS, ALL SEPARATION DISTANCES ARE TO BE VERIFIED PRIOR TO EXCAVATION. SITE PLAN AND LOCATION OF JOB NO. 15639W PERCOLATION HOLES FIGURE 1 'PROPOSED RESIDENCE SCALE LOT 3, RUEDI SHORES SUBDIVISION, FILING NO. 1 1" 20' SECTION 6, T8S, F18W, EAGLE COUNTY, COLORADO NN\ N,.%, N � INN- N`\NN Nk N'N NN, NN,1. NN IN `kk `N "IN NN 'N N, N N% % 'N \ N" N% N, NN. N11 Pli�O§ED NN NN. "N. �-BEWOOM ',N�4 IN" NN, 1� N IN k 4� % N, 1�. " N NI" %,N %N, IN'N . . "IN \11\lk N"N,NS. N' N%, N. N,NNNN".INk ,N,' 'NN, N\l l.NNNN"N, , Nit nN NC�RAN T \ \'N, 1 " \1NN�,%,'1 . NN'" N" 'Nry N NN1 %NN `\11N, N ,Nl� Nlk 1000-GALLON, TWO -COMPARTMENTS t, 0 \PRECAST CONCRETE NN, N., SEPTIC TANK WITH AN Y. EFFLUENT FILTER AT THE OUTLET %,11 :, \ N,1'. IN, N, N N 'l , , IN, 4N"\ ,�,Pvc SEWER LINE N , Nk '. 114� N, N, k "N" "tr.N %IN INNN, 'N N `NN, " NF Nl� ", % NN 11N, vh "'kh 1� IN "N NN lk "I.N.'. N \ 4 .., PVC SERIAL,, N, N N ... lNN,, NN `NN, OVERFLOW LINE W. N, NN'.,N1, 4, 11, N, k" NN,11 N, N '' .\ Nl� \ 1 .1 NN ,N. NNk N%4.° NN, 'N NNN, 511.5 SQ. FT. OF INFILTRATIVE AREA IN GRAVELLESS CHAMBER -TRENCHES. EACH 'TRENCH MUST HAVE ONE ROW OF 11 CHAMBERS EACH FOR A TOTAL OF 33 CHAMBERS. N N, NN, NN, N." IN E' A I /V� ,NN\ LOCATION OF PROPOSED OWS JOB NO. 15639W FIGURE 2 TYPICAL PLAN VIEW I TYPICAL CROSS-SECTION 3 TRENCHES I SLOpF FOR ORA�/VgO E �y R %BACKFILL 4' EXTENT OF EXCAVATION EWINEMS S GEO=G M PROJECT MANAGER: TRP ' MIN. - GRAVELLESS CHAMBER 5' BY 6.25' 4" SDR 55 PVC OBSERVATION/VENT PIPE WITH CAP 1.5' FIELD CROSS SECTION JOB NO. 15639W FIGURE 3 Q �c ® I Q Q 33� C `... F @ `o E U n rnf A o= m W 4 CL C7 �3 v-3 pi m o C7 Y7 v E`°� m� as > v vim: EQ� C0.0 o a)3 o$ c� o Lo o o, a= xa�v v p LL m U°: #cm v o o avvO1i °- Q, Cl N —v+m Ra E Q O C p WO.. E+i V7 �v �� �i.✓ !-- � l.ci �j h,. RS - co �. a) N U ,( U �> co 3 o _O C cn m Q CD cr N 1 CL tL O Q U Q U c N E Q € Nf E 0 0 �vC C1 0 O Q O a Woo o r m �t C O a• CY U O Q U o F C'J as93 _•c o 0 O O T -C U- O S _m ¢9 c z6 �o a¢ oLn 3 = in C3 Um =w U jE N Eo n- w c' z p LLI a. M CD Z a_ = 0 En ~ ul LLI In O W U viz w n o Ln N m u LO L' C E Fn M� Q T Of cn �n O C a =Nma o` �rn t ,, W LL J 0) co T z W 4 1 LOT 3, RUEDI SHORES HEPWORTH=PAWLAK GEOTECHNICAL, INC. . SUBSOIL STUDY FOR FOUNDATION DESIGN AND PERCOLATION TEST JOB NO. 102 486 AUGUST 28, 2002 , FROM PHONE NO. : 815 229 9250 Nov. 27 2002 12:09PM P7 Brad Lundgren August 28, 2002 Page 2 Subsurface Copd.- ions: The Subsurface conditions at ,he Site were evaluated by excavating two exploratory pits in the building area and one profile pit in the septic disposal area at the approximate locations shown on Fig. 1. The logs of the pits are presented on Fig. 2. The subsoils encountered, below about lliy feet of topsoil, consist of sandy clay with gravel overlying silty clayey sandy gravel with cobbles and scattered boulders. Results of swell -consolidation testing performed on a relatively undisturbed sample of sandy clay matrix, presented on Fig. 3, indicate low compressibility tinder existing low moisture condition and .moderate compressibility under additional Ioading after wetting. Results of a gradation analysis performed on a sample of silty sandy clayey gavel {minus 5 inch fraction) obtained from the site axe presented on Fig. 4. No free water was observed in the pits at the time of excavation and the soils were slightly Moist to moist. Foundation Recommendadons: Considering the subsoil conditions -encountered in the exploratory pits and the ;nature of the proposed construction, we recommend spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 2,000 psf for support of the proposed residence. The soils tend to compress after wetting and there could be some post -construction foundation settlement_ The subgrade. soils should be evaluated for settlement/kzeave potential at the time of construction. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and .disturbed soils encountered at the foundation bearizxg level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural soils. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 42 inches below the exterior grade is typically used in this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length.of at least 12 feet_ Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 55 pcf for the on -site soil as bacictill. A sliding coefficient of 0.4 and a passive earth pressure of 300 pcf equivalent fluid unit weight, can. be used to resist lateral loading on the foundation_ Floor Slabs: The natural on -site soils, exclusive of topsoil, are suitable to support Iightly loaded slab -on -grade construction. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement_ Floor slab control joints N-P GEOTEcx Received Time Nov•2-7. 11:00AM FROM : PHONE No. : 815 229 9250 Nov. 27 2002 12:11PM P9 Brad Lundgren August 28, 2002 Page 4 capped with about 2 feet of the or. -site, finer graded soils to reduce surface water infiltration. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 12 inches in the first 10 feet in unpaved areas and a mi-mmu* ru slope of 3 inches in the first 10 feet in pavement and walkway areas. A swale will be needed uphill to direct surface runoff around the residence and garage. 4) Roof downspouts and drains should discharge well beyond the limits of - all backfill. 5) Landscaping which requires regular heavy irrigation should be located at least 4 feet from the building. Percolation Testing: Percolation tests were conducted on August 20, 2002 to evaluate the feasibility of an infiltration septic disposal system at the site. ' One profile pit and throe percolation holes were dug at the locations shown on Fig. 1. The test holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The soils exposed in the percolation holes are similar to those exposed in the Profile Pit shown on Fig. 2 and . consist of topsoil and sandy clay overlying silty clayey sandy gravel with cobbles and scattered boulders_ The percolation tests were conducted in the sandy gravel soils. The percolation test results are presented in Table H. Based on the subsurface conditions encountered and the percolation test results, the tested area based in the gravel subsoils should be suitable for a conventional infiltration septic disposal system. A civil engineer should design the infiltration septic disposal system. Limitations: This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either expressed or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Fig. 1, the proposed type of construction and our experience in the area. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits and variations in the subsurface conditions may not become evident until excavation. is performed. If conditions encountered during -construction appear different from those described ill this report, we should be H-P GEOTEcH Received Time Nov.97. iI:n m FROM PHONE NO. : 815 229 9250 Nov. 27 2002 12:11PM P10 Brad Lundgren August 28, 2002 Page 5 notified at once so re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted_ Significant design changes may require additional analysis or modifications. to the recommendations presented herein. We recommend ors -site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engineer. If you have any questions or if we may be of further assistance, please let us know. Sincerely, HEPWORTH - PAWLAK GEOTECHNICAL, INC- Louis E. Eller Reviewed by: Steven L. PawIak, P. • LEE/ksw attachment i 15222 0 s �ssaH�i. ��'PO (JF C0�2 H-P GEa=H Received Ti-me Nov•27. 1140AM FROM PHONE NO. : 815 229 9250 Nov. 27 2002 12:12PM P12 PIT 1 E 0 m +4=52 200-24 10 LEGEND: PIT 2 PROFILE PIT yj D0�95 y$• WC=7.4 D0-107 •' •, 0. .o- 10 TOPSOIL; sandy silt and clay, organic, firm, slightly moist, dark brown. CLAY (CL); sandy to very sandy,. gravelly, stiff, slightly moist, reddish brown to brown, slightly porous and calcareous, medium plasticity, GRAVEL (GIN); silty, clayey, sandy, with cobbles and scattered boulders, medium dense to. dense, 019P'tly moist to moist, reddish brown to brown, subangular rock_ 2" Diameter hand driven liner sample. Disturbed bulk sample. _J NOTES: 1. Exploratory Pits were excavated on August. 19, 2002 with a Komatsu PC120 trackhoe. 2. Locations of exploratory pits were measured approximately by pacing from features on the site pion provided. 3. Elevotrons of exploratory pits were not measured and loge of exploratory pits are drawn to depth. 4.' Th.e exploratory pit locations should be considered accurate only to the degree implied by' the methdd used. S. Th'e Imes .between materials shown on the exploratory pit logs represent the approximate boundaries between material types and transitions may be gradual. 6. No .free water. was encountered in the pits at the time of excavating. Fluctuations in water revel may occur with time. 7. Laboratory Testing Results: WC:..-. -Welter Content (3b ) 09 — Dry Density ( pcf ) +4 — .- 4rceht. retained on No. 4 sieve --200 ::. Percent. passing No. 200 sieve 7,02: 486 '}'fEPWdRTH—PAWLAK LOGS OF ,EXPLORATORY PITS Fig. `GEOTF-CH-NICAL, INC. m l s a m en Received Time Nov.27. IIAAAM FROM.: PHONE NO. : 815 229 9250 Nov. -27 2002 12:14PM P16 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 11 PERCOLATION TEST RESULTS JOB CVO. 102 486 HOLE CIO. HOLE DEPTH LENGTH OF WATER DEPTH WATER DEPTH DROP IN AVERAGE (INCHES) INTERVAL AT START OF AT END OF WATER PERCOLATION I (MIN) INTERVAL INTERVAL LEVEL RATE (INCHES) (INCHES) (INCHES) (M1N.IINCH) P-1 ' 44 15 5 3/4 2 718 2 7/8 water added 6 1/4 5 112 3/4 5 112 4 518 718 -4 5/8 4 5/8 4 3 1/4 314 - 3 1/4 2 3/4 1/2 2 3/4 2 314 23 P-2 50 .15 8 3/4 . 4 23 4 • f 3 3/4 1/4- - ---- - - — _3_3L�- — - -27-L8- - 7I8- water added 5 4 1/2 4 1/2 4 3 114 314 3 114 2 112 3/4 23 P-3 •46 15 5 i /4 2 718 2 3/8 2 7/8 2 1/4 5/8 2 114 1 3/8 7/8 water added 4 1/8 3 1/4 718 3 1/4 2 112 314 2 112 1 7/8 518 1 7/8 1 1 /8 314 22 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on August 19, 2002. Percolation tests were conducted on August 20, 2002. The average percolation rate is based on the last three readings of each test_ Received Time Nov.21. 11:00AM ISDS Permit # 2Z101-4)5 Date '1I .( 103 ISDS Final Inspection CgMleteness Form Tank is L� gal. Tank Material Tank is located i �2ft. and a DG degrees from (permanent landmark) Tank is located ft. and degrees from (permanent landmark) Tank set level. Tank lids within 8" of finished grade. Size of field ft2 Technology units lineal ft. Cleanout is installed in between tank and house(+ 1/100ft). There is a "T" that goes down 14 inches in the inlet and outlet of the tank: .V , V-7 � - """ \,,`�Inlet and outlet is sealed with tar -,tape rubber gasket etc. ✓Tank.;has two compartments with the 1:arger..,;cotppartment closest to the house. 1 Measure distance and relative direction to:f,ield� �2 ou dk Depth of field. ft. O /ASoil interface raked. Inspection portals at the.end of each trench.. Proper distance to setbacks. Chambers properly installed as per manufacturers specifications. (Chambers latched, end plates properly installed, rocks 'removed from trenches, etc.) (� Type of pipe used for building sewer line ')40 leach field v Other Inspection meets feqUir6ments.. Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: Setbacks Well Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Field 100 25 20 10 50 25 10 10 Tank 50 10 5 10 50 10 * 10 +FROM :' PHONE NO. August 28, 2002 815 229 9250 Qov, 27 2Q02 :09PM P6 ai.t 1: 1-'-4" Hepworth- awls$ G Lee � .. *c Raadili lea 7" Glenwood Springs, Colorado 81601 Phone:970-945-7988 Fnx- 970-94S-8454 hpgeocc�hpgeotech.com Brad Lundgren 913 North Main, #1408 Rockford, Illinois 61103 Job No. 102 486 Subject: Subsoil Study for Foundations Design and Percolation Test, Proposed. Residence, Lot 3, Ruedi Shores, Eagle County, Colorado Dear Mr. Lundgren: As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and percolation test for foundation and septic disposal designs at the subject site. The study was conducted in accordance with our agreement for geotechnsical engineering services to -you dated July 15, 2002 and amended by our letter dated August 1, 2002. The data obtained and our recommendations based on the proposed construction and subsurface conditions encountered are presented in this report. Evaluation of potential geologic hazard impacts on the site are beyond the scope of this study. Proposed Construction: The proposed residence will be a one to two story wood frame structure above a walkout basement and with a detached garage located on the site approximately as shown on Fig.1. Ground floors are proposed to be slab -on -grade. Cut depths are expected to range between about 4 to 12 feet. Foundation loadings for .this type of construction are assumed to be relatively light and typical of the proposed type of construction. The septic disposal systems is proposed to be located downhill and south of the residence, If building conditions or foilnd.ation -loadings are significantly different from those described above, we should be notified to re-evaluate the recommendations presented in this report. Site Conditions: The lot is located on the southwest side of McLaughlin Lane in the -southern part of -the subdivision near Frying Pan Road. The ground surface in the -building area slopes steeply down to the southwest on the order of 30%. There is about 1 -a-7 foot high fill embankment off of McLaughlin Lane. The lot is vegetated with abundant sagebrush, grass, weeds and scattered aspen and evergreen trees. Scattered . subangular cobbles are exposed at the ground surface. Received Time Nov.27. 11:00AM FROM PHONE NO. : 815 229 9250 Nov. 27 2002 12:09PM P7 Brad Lundgren August 28, 2002 Page 2 Subsurface Conditions: The subsurface conditions at the site were evaluated by excavating two exploratory pits in the building area and one profile pit in the septic disposal area at the approximate locations shown on Fig. 1. The logs of the pits are presented on Fig. 2. The subsoils encountered, below about 11iy feet of topsoil, consist of sandy clay with gravel overlying silty clayey sandy gravel with cobbles and scattered boulders. Results of swell -consolidation testing performed on a relatively undisturbed sample of sandy clay matrix, presented on Fig_ 3, indicate low compressibility under existing low moisture condition and moderate compressibility under additional Ioading after wetting. Results of a gradation analysis performed on a sample of silty sandy clayey gravel (minus 5 inch fraction) obtained from the site are presented on Fig. 4. No free water was observed in the pits at the time of excavation and the soils were slightly moist to moist. Foundation Recommendations: Considering the subsoil conditions' encountered in the exploratory pits and the mature of the proposed construction, we recommend spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 2,000 psf for support of the proposed residence. The soils tend to compress after wetting and there could be some post -construction foundation settlement_ The subgrade. soils should be evaluated for settlement/heave potential at the time of construction. Footings should be a minimum Width of 16 inches for cozetinuous walls and 2 feet for columns. Loose and disturbed soils encountered at the foundation bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural soils. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 42 inches below the exterior grade is typically used in this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length.of at least 12 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 55 pcf for the on -site soil as backfill. A sliding coefficient of 0.4 and a passive earth pressure of 300 pcf equivalent fluid unit weight, can be used to resist lateral loading on the foundation. Floor'Slabs: The natural on -site soils, exclusive of topsoil, are suitable to support lightly loaded slab -on -grade construction. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movemment. Floor slab control joints N-P GEOTECN Received Time Nov•27. 11:00AM FROM PHONE NO. : 815 229 9250 Nov. 27 2002 12:10PM P8 Brad Lundgren August 28, 2002 Page 3 should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of free -draining gravel should be placed beneath basement level slabs to facilitate drainage. This material should consist of minus 2 inch aggregate with less than 50% passing the Nd. 4 sieve and less than 2% passing the No. 200 sieve. .All fill materials -for support of floor slabs should be compacted to at least 95% of maximum standard Proctor density at a moisture content riear optimum. Required fill can consist of the on -site soils devoid of vegetation, topsoil and oversized rock. Underdrain System: Although free water was not encountered during our exploration, it has been our experience in mountainous areas that local perched groundwater can develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can create a perched condition. We recommend below -grade construction, such as retaining wills, crawlspace and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. The drains should consist of drainpipe placed in the bottom of the wall backfill -surrounded above the invert level with free -draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and sloped at a minimum 1 % to a suitable gravity outlet. Free -draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 11/2 feet deep. Surface Drainage: The following drainage precautions should be observed during construction and maintained at all times after the residence and garage have been completed: 1) Inundation. of the foundation excavations and underslab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas_ Free -draining wall backfill should be H-P GEOTECH Received Time Nov.27• I1:00AM FROM PHONE NO. : 815 229 9250 Nov. 27 2002 12:11PM P9 Brad Lundgren August 28, 2002 Page 4 capped with about 2 feet of the on -site, finer graded soils to reduce surface water infiltration. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in pavement and walkway areas. A swale will be'needed uphill to direct surface runoff around the residence and garage. 4) Roof downspouts and drains should discharge well beyond the limits of - all backfill. 5) Landscaping which requires regular heavy irrigation should be located at least 4 feet from the building. Percolation Testing: Percolation tests were conducted on August 20, 2002 to evaluate the feasibility of an infiltration septic disposal system at the site. ' One profile pit and three percolation holes were dug at the locations shown on Fig. 1. The test holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The soils exposed in the percolation holes are similar to those exposed in the Profile Pit shown on Fig. 2 and consist of topsoil and sandy clay overlying silty clayey sandy gravel with cobbles and scattered boulders. The percolation tests were conducted in the sandy gravel soils. The percolation test results are presented in 'fable ii. Based on the subsurface conditions encountered and the percolation test results, the tested area based in the gravel subsoils should be suitable for a conventional infiltration septic disposal system. A civil engineer should design the infiltration septic disposal system. limitations: This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either expressed or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Fig. 1, the proposed type of construction and our experience in the area. Olin findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits and variations in the subsurface conditions may not become evident until excavation is performed. if conditions encountered during construction appear different from those described in this report, we should be H-P GEOTECH Received Time Nov•21• II:00AM FROM PHONE NO. : 815 229 9250 Nov. 27 2002 12:11PM P10 Brad Lundgren August 28, 2002 Page 5 notified at once so re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been; appropriately interpreted_ Sign ificant design changes may require additional analysis or modifications. to the recommendations presented herein. We recommend on -site observation of excavations and foundation bearixig strata and testing of structural fill by a representative of the geotechnical engineer. If you have any questions or if we may be of further assistance, please let us lmow. Sincerely, HEPWORTH - PAWLAK GEOTECHNICAL, INC. Louis E. Eller Reviewed by: Steven L. Paw LEEIksw attachments H-P GEOTECH Received Time Nov.27. 11:OOAM FROM LOT 4 PHONE NO. : 815 229 9250 MCLAUGHLIM LANE PROPOSED GARAGE PIT i RESIDEN Y V ■ PET 2 P 2A z P 3 IT 3 Nov. 27 2002 12:12PM P11 APPROXIMATE SCALE i"_40' i 1 4$6 .. HEPWORTH--PAWLAK LOCATION OF EXPLORATORY PITS GEOTECHNICAL, INC. AND PERCOLATION TEST HOLES Received Time Nov.27. 11:00AM LOT 2 1 1 FROM PHONE NO. : 815 229 9250 Nov. 27 2002 12:12PM P12 PIT i PIT 2 PROFILE PIT 0 0 I -200-66 ;' B• I ,s +4362 WC-7.4 t -200-24 • '.did :dQ oR � 10 'Q• 10 LEGEND: ® TOPSOIL; sandy silt and day, organic, firm, slightly moist, dark brown. CLAY (CL); sandy to very sandy, gravelly, stiff, sllghtiy moist, reddish brown to brown, slightly porous and caicareous, medium plasticity. .;a GRAVEL (GM); silty, clayey, sandy, with cobbles and scattered boulders, medium dense to. dense, slIgh'tly moist to moist, reddish brown to brown, subangular rock_ 2" Diameter hand driven liner sample.' " �i Disturbed bulk sample. Ps NOTES: 1. Exploratory pits were excavated on August 19. 2002 with a Komatsu PC120 trackhoe. 2.. Locations of exploratory pits were measured approximately by pacing from features on the site plan provided. 3. Elevations of exploratory pits were not measured and logs of exploratory pits are drawn to depth. 4. The exploratory pit locations should be considered accurate only to the degree implied by the method uned. a. The lines . between materials shown on the exploratory pit logs represent the approximate boundaries between material types and transitions may be gradual. 6. No .free water. was encountered in the pits at the time of excavating. Fluctuations in water level may occur with time. 7. Laboratory Testing Results: WC:.-. Wdtar Content ( X ) 017— Dry Density ( pcf } +4 —...Percent. retained on No. 4 sieve •-�200 :­. 'Percent. passing No. 200 sieve 1.®2..48� : i-fEPWORTH—I?AWLAK LOGS OF EXPLORATORY PITS Fig. GEOTECHNICAL., INC. Received Time Nov•21. II:00AM FROM PHONE NO. : 815 229 9250 Nov. 27 2002 12:13PM P13 Moisture Content = 7.4 Dry Density — 107 Sample of: Sandy Ciay Motrix From: Pit 2 at 6 Feet M Compression upon wetting a. 5 percent gcf 0.1 1.0 10 100 APPUED PRESSURE — ksf G 1-02.486. -HEPWORTH—PAWLAK SWELL CONSOLIDATION TEST RESULTS Fig. 3. ' ,GEOTECHNICAL, INC. Received Time Nov.27• II:00AM FROM PHONE .: 815 229 5 Nov. 27 2002 12:14P M P15 5 \ & � » x §( »* > co k . u U ® m � � 7 § � _ § k $ £ S ` .B . \ K k ' 2 • -� K � � \ Ci f- � n co . .0 . $ Cj I I . D — ;w tea T:,�= �, 97 Li I fl n A W -LL FROM PHONE NO. : 815 229 9250 Nov. 27 2002 12:14PM P16 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 11 PERCOLATION TEST RESULTS JOB NO. 702 486 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 15 water added 5 3/4 2 718 2 7/8 23 6 1/4 5 1/2 314 5 112 4 518 718 •4 5/8 4 518 4 3 1/4 3/4 3 114 2 3/4 1/2 2 314 2 3/4 P-2 50 15 water added 6 3/4 4 2 314 23 4 3 3/4 1/4 3 3/4 2 7/8 7/8 5 4 112 1 /2 4 112 4 1/2 4 3 1/4 3/4 3 114 2 1/2 3/4 P-3 -46 15 water added 5 1/4 2 7/8 2 3/8 22 2 718 2 114 5/8 2 114 1 3/8 718 4 1/8 3 1/4 718 3 1/4 2 1/2 3/4 2 1/2 1 7/8 5/$ 1 7/8 1 1/8 314 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on August 19, 2.002. Percolation tests were conducted on August 20, 2002. The average percolation rate Is based on the last three readings of each test_ Received Time Nov.27. 11:00AM 2261-03 Tax #2471-063-06-012 NAME. Lot #3, Ruedi Shores LUNDGREN 407 McLaughlin, Basalt JOB NO. N i q I LOCATION BILL TO DATE STA TED LO 5 DATE COMPLETED DATE BILLED V11 (),Q Alt, �.6 4- -2- 1I5. �'kz 010 x,,�1� �t C)j - �- Pto JOB COST SUMMARY TOTAL SELLING PRICE TOTAL TOTA _ _ _~ —r'"- i In i 4y' k.. -. o r �0C) fps -/`L71 71 l D l)�X�'67 � /u-a&&vf dab- 1 W i 4 Lliikt wt�t WJ JOB FOLDER Product 278 d e6 j Q r, C o(-' �-tc�v�" C �(/L��G ZZ�1-03 `bB FOLDER 0- 3 407 J i I � Q _ a2(Pl-U3 cf-4 -71J03 1 �(orcF�3 I�,(��-�i �,�nSi�Ic r�s k �fr7�3-�C., 14D 1 ),� LC1J ,q 44✓1 SL �� x �4 r ,4 M S - � 4 s a. i r k V t7 u TA' V C'I--1Z T NT!7- 201 MAIN STREET #304 CARBONDALE, COLORADO 81623 (970) 704-9750 Phone: (970) 704-9750 Fax: (970) 704-0287 E-Mail: jma@sopris.net ISSUED FOR DATE PROGRESS SET 01/01/03 PROGRESS SET 01/23/03 PROGRESS SET 01/27/03 PRICING SET 02/10/03 DRAWING SITE PLAN DATE. 02/10/03 PROJECT LUNDGREN RESIDENCE A1.1