About
1241 Red Canyon Rd - 194124402007
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway X Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2266-03 BUILDING PERMIT NO. 15069 OWNER: PAUL GRUBER PHONE: 970-926-5944 MAILING ADDRESS: P.O. BOX 4239, EDWARDS, CO 81632 APPLICANT: SAME PHONE: SYSTEM LOCATION: 1241 RED CANYON CREEK RD., EDWARDS, CO. TAX PARCEL NO. 1941-224-02-007 LICENSED INSTALLER: LCI, INC., SHELDON KUHNS LICENSE NO. 25-03 PHONE: 970-390-4+45 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR THE BARN BATHROOM 1000 GALLON SEPTIC TANK, 186 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 6 INFILTRATOR UNITS, AS PER ENGINEER'S DESIGN DATED 4/22/03. SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN WITH A CLEANOUT BETWEEN THE TANK AND THE BARN AND AN INSPECTION PORTAL AT THE END OF THE TRENCH. RAKE ALL TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS AND DO NOT INSTALL IN WET WEATHER. BE SURE TO MAIN ALL SET BACK REQUIREMENTS, ESPECIALLY THE MINIMUM 50 FT FROM THE STREAM TO THE LEACH AND TANK. CALL EAGLE COUNTY ENVIRON- MENTAL HEALTH AND DESIGN ENGINEER FOR THE FINAL INSPECTION PRIOR TO BACK FILLING WITH ANY PART OF THE INSTALLATION OR WITH ANY QUESTIONS REGARDING THE INSTALLATION. THE CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROVAL: LAURA FAWCETT DATE: JUNE 25, 2003 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID,ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 186 SQUARE FEET (VIA 6 INFILTRATOR UNITS PER DESIGN ) INSTALLED PLASTIC SEPTIC TANK: 1000 GALLONS IS LOCATED 180 DEGREES AND 15 FEET INCHES FROM THE CLEANOUT ON THE SOUTH WEST SIDE OF THE BARN COMMENTS: THE FINAL INSPECTION WAS DONE BY VICTOR CROCCO OF EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER ON 7/17/03. THE ENGINEER'S FINAL CERTIFICATION WAS RECEIVED ON 8/11/03. THIS SYSTEM IS ONLY LARGE ENOUGH TO ACCOMMODATE THE SINGLE BATHROOM IN THE BARN. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE - INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL DATE: AUGUST 19, 2003 Incomplete Applications Will NOT Be Accepted (Site Plan MUST be attached)c! ISDS Permit # � A (J Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 Eagle (970)328-8755, Fax (970)328-0349, El Jebel (970)927-3823 **************************************************************************** * FEE SCHEDULE APPLICATION FEE $350.00 * THIS FEE INCLUDES THE ISDS PERMIT, SITE EVALUATION (PERCOLATION TEST, * SOIL PROFILE OBSERVATION) AND FINAL INSPECTION * ADDITIONAL FEES MAY BE CHARGED IF A REINSPECTION IS NECESSARY, OR A * PRE -CONSTRUCTION SITE VISIT OR CONSULTATION IS NEEDED * REINSPECTION FEE $47.00, PRE -CONSTRUCTION SITE VISIT FEE $85.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" **************************************************************************** PROPERTY OWNER: -le k— MAILING ADDRESS: / a A(pk �2 � 9y�5' PHONE: 6 ` APPLICANT/CONTACT PERSON: 6, ( ( 061P4_ PHONE: 3 /%,-j/, LICENSED SYSTEMS CONTRACTOR: S- ,o f/I., PHONE: ?� — yc 5;-S— COMPANY/DBA: �_ C _Z_ ADDRESS: n /-3Q � 77tel", PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION WALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: LU" ��li �� y, ry, s- f4 f -<o 5 Tax Parcel Number: l /� 7 / �/�Q C>6 `7 Lot Size: �G r Physical Address: BUILDING TYPE: (Check applicable category) ( ) Residential/Single Family Number of Bedrooms ( ) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* / *These systems require design by a Registered Professional Engineer TYPE OF.,WATER SUPPLY: (Check applicable category) Well ( ) Spring ( ) Surface ( ) Public Name of Supplier: AP PL I CANT S I GNATURE : />�'Z._st e : G Cs AMOUNT PAID: RECEIPT #: /2 q-2 % DATE: t, ' CHECK #: _5003 CASHIER: - DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE:800-225-6136 www.eagle-county.com DATE: June 25, 2003 TO: Logan Craig, Inc. EAGLE COUNTY FROM: Eagle County Department of Environmental Health RAYMOND P. MERRY, REHS Director RE: Individual Sewage Disposal System Permit #2266-03 Tax Parcel # 1941-224-02-007, Property Location: 1241 Red Canyon Creek Rd., Edwards, CO., Gruber barn. Enclosed is your ISDS Permit #2266-03, and a copy of the engineer's design for this system. The permit is valid for 120 days or for the duration of your current building permit for this property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidate the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this Department. Systems that are designed by a Registered Professional Engineer must be certified by the engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer and views the installation. Please note that our ISDS Permit specifications are typically minimum requirements only and should be brought to the property owner's attention in case they may wish to install a system capable of handling larger wastewater flows. This permit does not indicate conformance with any other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact us at (970) 328-8755. cc: ISDS file # 2282-03 LKP Engineering, Luiza Petrovska Chrono file June 2003 OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 Engineering, Inc. CIVIL/GEOTECHNICAL April 21, 2003 Mr. Paul Gruber P.O. Box 4239 Edwards, CO 81632 Dear Paul: RE: Open Hole Observation - Barn Lot 8, Red Canyon Estates Eagle County, Colorado Project No. 03041 At the request of Sheldon, on April 18, 2003, we visited the construction site on Lot 8, Red Canyon Estates, Eagle County, Colorado. The purpose of our site visit, was to observe the soils exposed in the foundation excavation for the barn and compare them with the findings and recommendations of the Soil and Foundation Investigation Report, Project Number 2093, dated June 7, 2000. The excavation consisted of one, "U"-shaped trench. The trench was located at the base of the hillside. The soil exposed in the foundation excavation consisted of shale and sandstone bedrock. The soil exposed at the bottom of the excavation is suitable for the bearing capacity of 1500 psf, recommended in the above -named soil's report. We understand that this trench is for the back, foundation/retaining wall only, and individual footing pads will be constructed at a later date to support the front part of the barn. These pads will be supported on undisturbed soil, while the area for the support of the slab on grade will receive a structural fill. They used the on site, silty, gravelly sand for the backfill. A Standard Proctor Test was done on the backfill material. It had 115 pcf maximum dry density and 11.5% optimum moisture content. We measured the field density of the compacted soil with a nuclear gauge, according to the ASTM Standard D 2922-91, Test Methods for Density of Soil and Soil -Aggregate In Place by Nuclear Methods. We tested the first and second lift of the structural fill under the slab on grade area. The test results ranged from 92.6 to 97.9 percent of the maximum dry density. The test results are appended to this report. We recommend following the recommendations of the above -named soil's report during the remainder of the construction, specifically the sections on drainage and grading. If you have any questions, please do not hesitate to call. Sincerely, M rF LKP Engineering, In ZZO-) We- 7( 2JZ Luiza Petrovska, P President AL Enclosure C:\WP 10-LKP\0304I OPEN.wpd P.O. Box 2837, Edwards, CO 81632, (970) 926-9088 Tel, (970) 926-9089 Fax r L P . Engineeringg Inc. CIVIL/090TRMNICAL August 11, 2003 Mr. Paul Gruber P.O. Box 4239 Edwards, CO 81632 Dear Paul: RE: Inspection of Septic System Installation, Lot S, heel Canyon Estates Barn 1241 Red Canyon Creek -Road Eagle County, Colorado ]project No. 03041 Permit No. 2266-03 At the request of Sheldon., on July 11, 2003, we visited the construction site on Lot 9, Red Canyon Estates, 1241 Red Canyon Creels Road, Eagle County, Colorado. The purpose of our site visit was to observe the installation of the septic system for the barn. They installed the system in overall compliance with the septic system design, Drawing .No. 03041 SD.DWG, dated April 22, 2003. They installed a 1000-gallon, two -compartments, septic tank. A clean out was constructed between the septic tank and the foundation gall of the proposed barn. The effluent line from the septic tank to the first infiltrator of the leachfield was a total distance of 14 feet. Six, Standard Infiltrator Chambers were installed in one trench, as shown on the attached sketch. In the first and last, infiltrator, inspection ports were installed. The depth of the trench was no more than 36 inches. If you have an Sincerely, �q "°W �, LIB Engineers fW 0.3 a i to-y uiza Petrovska, ®.o . President ` ;��@. do not hesitate to call. cc: Ms. Laura Fawcett, Eagle County Environmental I-Iealth Division, fax: 328-0349 Enclosure C:1WP10-LKP\03043 OSI.wpd P.Q. Box 2937, Edwards, CO 81632, (970) 926-9088 Tel, (970) 926-9089 Fax TA -IqW 1 ')WT PWT'AggWTnWq A'M-I F,AMFg7PM1 r_ 7P'bT �W271TT1QQ ISDS PERMIT # PERCOLATION TEST EAGLE COUNTY ENVIRONMENTAL HEATLH -PHSYSICAL ADDRESS: _ LEGAL DESCRIPTION: MAILING ADDRESS: 00 '�ff TYPE OF DWELLING:NUMBER OF BEDROOMS: f. TEST HOLES PRE-SOAKED: YES NO SOIL TIME WATER DEPTH INCHES OF FALL RATE PROFILE n� mmmm mmmmmm mmmmmm I livM I V IJKUY LAJ I- INCH: PERC RATE: MINIMUM LEACH FIELD SIZE: MINIMUM SEPTIC TANK SIZE: 4 ENVIRONMENTAL HEALTH SPECIALIST DATE W 4,y INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2019-00 BP NO. 13300 OWNER: MAJACK LLC PHONE: 970-926-0986 MAILING ADDRESS: P.O. BOX 2487, EDWARDS, CO 81632 APPLICANT: SCOTT SCHMIDT PHONE: 970-926-0986 SYSTEM LOCATION: 1241 RED CANYON CREEK ROAD, EDWARDS, CO TAX PARCEL NO. 1941-244-02-005 LICENSED INSTALLER: T. NOTTINGHAM CONSTRUCTION, TERE NOTTINGHAM LICENSE NO. 37-00 PHONE: 970-471-2711 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 5 BEDROOM RESIDENCE 1500 GALLON 3-COMPARTMENT SEPTIC TANK WITH AN ELECTRIC LIFT STATION WITH AN ALARM, 1875 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 60 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN DATED 7/17/00. SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN, IN SERIAL DISTRIBUTION IN TRENCHES ALONG THE CONTOURS. BE SURE TO MAINTAIN ALL APPLICABLE SET BACK REQUIREMENTS. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. DO NOT BACK FILL ANY PORTION OF THE INSTALLATION UNTIL THE ENGINEER HAS INSPECTED AND APPROVED IT. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROVAL: DATE: AUGUST 9, 2000 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 18 7 5 SQUARE FEET (VIA 60 INFILTRATOR UNITS ) INSTALLED. CONCRETE SEPTICTANK: 1 500GALLONS IS LOCATED 156 DEGREES AND 15 FEET 6 INCHES FROM THE CLEANOUT ON THE SOUTH SIDE OF THE HOUSE. COMMENTS: THE FINAL INSPECTIONS WERE DONE BY LAURA FAWCETT OF RA LF COUNTY ENV HEALTH AND THE DESIGN ENGINEER ON JULY 17 and 18, 2001 THE FINAL ENGINEER CERTIF*CTION WAS RECEIVED ON NOVEMBER 8, 2001. THIS SYSTEM IS LARGE ENOUGH FOR 9--FIVE BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ' ' , " ENVIRONMENTAL HEALTH APPROVAL 4Lay c.l.� vz_� DATE: NOVEMBER 8, 2 0 01 complete Applications Will NOT Be Accepted c _(Site Plan MUST be attached) �J ISDS Permit # 1� Building Permit # /?1 5 (7n APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631. 328-8755/927-3823 (El Jebel) ************************************************************************** * FEE SCHEDULE * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * SIZING AND SITE VISIT FEE $85.00 (WHEN ENVIRONMENTAL HEALTH SIZES THE * SYSTEM USING YOUR SOILS REPORT) * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" ********************************i****************************************** PROPERTY OWNER: L �CiL LC - MAILING ADDRESS: PDX 016 2 PHONE: 726- L� tort ilA'iPHONE: APPLICANT/CONTACT PERSON: LICENSED SYSTEMS CONTRACTOR: !V m ������• PHONE: COMPANY/DBA: / e j'�*1,jG,, h �Y�� i� ADDRESS: &lc *************************************************************************** PERMIT APPLICATION IS FOR: (—T__NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL Legal Description: L ��- 8 A 1 Tax Parcel Number: Physical Address: SYSTEM: %5'l-2i>2 • aCF!� Lot Size: BUILDING TYPE: (Check applicable category) (Residential/Single Family Number of Bedrooms ( ) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type *These systems require design by a Registered Professional Engineer TYPE OF WA ER SUPPLY: (Chec pplicable category) ( ' We11 ( ) Spri4/lier ( S rf ace ( ) Public Name of,i� APPLICANT SIGNATURE: AMOUNT PAID: �� •©� RECEI PT # : DATE: O �` CHECK #: CASHIER: DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO November 8, 2001 Maj ack, LLC Attn: Larry Schmidt P.O. Box 2487 Edwards, CO 81532 Raymond P. Merry, REHS Director RE: Final of ISDS Permit #2019-00 Tax Parcel #1941-244-02-005. Property location: 1241 Red Canyon Creek Rd., Edwards, CO. Dear Mr. Schmidt: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sinc rely, r Janet Kohl Eagle County Environmental Health Department ENCL: Informational Brochure Final ISDS Permit cc: files OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 Community Development Department (970)328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com Date: August 9, 2000 EAGLE COUNTY, COLORADO TO: T. Nottingham Construction FROM: Environmental Health Division Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Issuance of Individual Sewage Disposal System Permit No.2019-00. Property Location: 1241 Red Canyon Creek Rd., Edwards, CO., Majack LLL property. Enclosed is your ISDS Permit No. 2019-00. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files LKP Engineering, Luiza Petrovska .L.LI euoj LCJF:Il 1J. J1 7 iCJ7L47Y_177 L-Kr LINUIIVttKINU INN I-'AUL ► i nee m 5 �jj s CMUGIRQTlrCIMCAL N oveanber 8, 2001 Mir. Scott Schmidt RE: Irnsnection of Sentic System Installation P.O. Box 2104 Lot 8, Red Canyon Estates Eagle County, Colorado Project No. 2093 - Permit No. 201.9-00 Dear Scott: ,At the request of Were Nottingham, on June 29 and July 18, 2001, we visited the construction site on Lot 8, Red Canyon Estates, 12.41 Red Canyon Creep Road., Eagle County, Colorado. 1 he purpose of our site visits was to observe the installation of the septic system. They installed the system in overall compliance with the septic system design, Drawing No. 2093SD.DWG, dated July 17, 2000. They installed a 1.500-gallon, three compartments, precast, a concrete, septic tank. In the last compartment of the septic tank, was a Zoeller Pump, Model 292, The tank had tree access openings, one over each of the compartments. The effluent line from the pump tank to the first infiltrator of the leachfteld was a total distance of 166 feet. The effluent line was 3-inch diameter schr40 pvc. The pump was sized to have 291 gal,j,ons per dose. The dosing, the floats function and the alarms were tested by Were Nottingham. The alarm was to be installed in the downstairs hallway. Sixty, Standard Infiltrator Chawhe7 were i mtalled in seven tx=ehe , as shown on the attached sketch. The first three trenches contained text, infiltrators each, the fourth had eight, the fib had seven, the si h had eight, and the seventh had i seven. infiltrators. The infiltrators were connected with serial distribution. The second axed third ifxltyators of the sixth trench were repaired by placing new infiltrators on tap of there. In the first and last infiltrator of each trench, inspwion? p w hnstWled, Honzontal clis ce from cente-r to center of the trenches, was 9 feet or ;more. The inlet of the effluent line to the first infiltrator was sealed. The depth of the trenches was no more than 36 inches. If you have any qtz&•please do not hesitate to call. Sincerely,FTa�d�' LOP Engineerin : '` 0 029526 R � u za Petrovska P President f'�f}F►�BDSPIP^�7.3,: cc: Ms. Laura Fawcett, Eagle County Envirofinezxtal kIealth Division, fax. 32$-0349 nc E JLil�+ V 7'4,I.L e C:\ gyp`![cslcoreldoc%WPDOCS120930SI-lump.WF1a P.4. Box 2837, Edwards, CO 81632, (970) 92&9088 Tel, (q70) 926-9()89 Fax ISDS Perini Date (.0 /-2q/c)/ �q "c,, � ISDS Final Inspection �� Completeness Form %13 ib Tank is 1� ou gal. Tank Material C tB Tank is located L- r � ft. and 6-- degrees from (persanent landmark) Tank is located ft. and degrees (permanent landmark) i Tank set level. Tank lids within 8" of finished grade. V� Size of field ft2 units lineal ft. Technology 'I f n Zk: n toy -I-td � Cleanout is installed in between tank and house(+ 1/100ft). /There is a "T" that goes down 14 inches in the inlet and outlet of the tank;__:_.----- nlet . and outlet' is sealed with tar,,t rubber gasket etc. _ T k has two metes with the:.. rger..c9tnpartment closest to the :. house. easure: distance and relative di re�cton to:field: 10 Depth of field. ft. �O tj1P, Soil interface raked. f,-1 Inspection portals at the.end of each trench._ Proper distance to setbacks. Chambers properly installed as per manufacturers specifications. (Chambers latched, end plates properly installed, rocks removed from trenches, etc.) ►/ Type of pipe used for building sewer line 41/1g.3 �� leach field • Other Inspectioxi meets requirements. Copy form to installer's file if recommendations for improvement.were suggested. ACTION TAKEN: - - Setbacks 'D Well Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Field 100 25 20 10 50 25 10 10 Tank 50 10 5 10 50 10 * 10 kidj11j1kiud 14:dz 7IUjzbluull cnr ii-iw -- xv 3 6806-9Z6 (OL6) `10,18806-9Z6 (OL6) `Z£918 00 `spigP `L£$Z X°S 'Q d ---- - - ---- � —. ---- - ...-sin—r r,ui iirnl -ru PpC�F:a Date 7- 17 -0,.3 ermit it6 6 - A ISDS P Timis FiDacti on_ - ��t ste*:aes Lrorm _ Tank is .0 5 0 gal. Tank Materialo a Tank is located I S ft. and =degrees � l� Tank is located __ft- and degrees from -- Tank set level. Tank lids within 6" of finished grade. ft Size of field = units _ lineal ft. Technology �Cleanout is installed iri between tank and house (+ 1/100ft) ._ ✓ There is a "T" that goes down 14 inches in the inlet and utlet of the tank-. et.and outlet is sealed with tax;_tape,. rubber gasket etc. -has t : a:ompartments with the.:-�;a.-,c-.pWpaXtmtent closest to the A �, house _ - .. .. . . i S' t o N relative dip car: to:e. l�t+atahurer ds,srarnce and _ Depth of field._ , S- 3��ft . .. t/ Soi.i interface raked. = -: ✓ nspectioa portals at the.end_of each trench.. proper distance to setbacks. ",-Z_ Chambers properly installed as per manufacturer$ specifications. (chambers latched, end plates properly installed, rocks kemoved from trenches, etc.) - S k,,.0 A-w, Type of pipe used for building sewer. line -Lb R 31 , leach field t h , �her - - inspection meets Copy fors to installers file if recommendations for improvement were suggested. ACTION TAKEN: 8 O e h ✓ r Setbacks well -Potable House Property Lake Dry Tank Drain WatCr Lines ine Stream Gulch Fied L00 25 20 10 50 25 10 10 50 10 5 10 50 10 * 10 ,wB 1266-A,673 E E- GE)UNTY-EW; REALTH P.O. BOX 179 EAGLE, CO 81631 SHEET NO. / pp CALCULATED BY- V f d c C O DATE 7- / 7- 0 CHECKED BY DATE SCALE _-- DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eagle-county.com August 19, 2003 Paul Gruber P.O. Box 4239 Edwards, CO 81632 EAGLE COUNTY RAYMOND P. MERRY, REHS Director RE: Final of ISDS Permit #2266-3, Tax Parcel #1941-224-02-007. Property location: 1241 Red Canyon Creek Rd., Edwards, CO. Dear Mr. Gruber: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Eagle County Environmental Health Department ENCL: Informational Brochure, Final ISDS Permit cc: files, August Chrono file OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 APR-23-2003 WED 01:16 PM CUSTOMER SERVICE FAX N0, 18005664022 P. 02 O SY,9TEMS INC Environmental onsita wastewater solutions"" April 23, 2003 To whom it may concern The manufacturer requires a minimum number of chambers for any leachfield, typically 10 to 12 chambers. In a situation where additional chambers will be used separately from the residential leachfield, as is this case for a half -bath in a barn for the homeowner(s), then a smaller amount of chambers could be recommended. Five to six chambers should be effective to handle the small daily flow from a toilet and wash basin That only two people would be using occasionally, and additional chambers could always be added in the future if needed. Jean Hutchinson ,-?Ma am`�� Market Development Infiltrator Systems, Inc 800-221-4436 860-577-7103 lJc.>curr'1r.:ntl corporate Office 04/9:S/0.3 P.O. Box 768 • 6 Business Park Road . Old Saybrook, CT 06475 . (860) 577 7000 - Fax (sso) 577-7007 .: •,. fir' � � .•� �r �'r ��^ ►. .t.�1a�' ,:., .. ''t.� �' -»,fit, y ' , �. • 2 '% Y�r' y �'��j t t��'!�~ l` . 1 �, �G yh�i��,, 'r '..IT�'! ' �.. pie •E r... <. `�..� i\�c` ` " �.�,�t�' •ems S 4 ,. � � ` ` - It . , �• _ � •fit � j. , _ ' it ` � � ,;, -v-�r'Zi'I '�• ` • �_ r ; \ `, iIr 0, , I IV- �'i Sr � Ky�l'� - L'.,V � 41 V, I' R VTI N 2019-00 Tax #1941-244-02-005 2266A-03 Tax #1941-224-02-007 JOB NAME _ Lot #8, Red Canyon MAJACK LLC_ Lot #8 Red Canyon Estates GRUBER Estates, 1241 Red Canyon Creek Rd. BARN 1241 Red Canvon Creak Rd_ _ var., -A- fln JOB NO. �? " .• DATE COMPLETED DATE BILLED ENOl / �ljl oil 1�1 / JOB COST G_ .. � � G t VLR � + • % ILA �!1 TOTAL SELLING PRICE TOTAL MATERIAL + "� INSURANCE ONE _ _■ • COSTS NE 1r. I ice_ tt•_•����.�Ls' � •, TOTAL•- co mmGROSS PROFIT: COSTS LESS OV% OF SELLING PRICE SERHEAD NET PROFIT JOB FOWM Product 278 JOB FOLDER (!Z' Pied In US.A. } !! �v�. ,UZ��i1-1 is ���{e."�t,yt(yZfI�7� c�c 1000 c 4 V 4-6 U 0,3 c' jO s d 9GliaN CA, � S C r t t co r- Cr ((' G G• S z c i c C) MO y Recycled Content 10% Post -Consumer i m DETAIL --A Dbmr.wrr _ CoodUm Cbwnbw/h vb*$Ww CW& / l if l r—r rr- r r w S35vwtto kWh NO,--- PRO cc T C �: -2os - _ DAB T a d N PROPOSED 18"/ULVERT= 59 L.F. ® 1.7% INV IN=12.5 INV OUT=11.5 U _ XISTiNC ` - STREAM 4' DIAMETER SDR35 BUILDING SEK R i 1.7 4' BOULDER WALL_, n � }2` cLEANouT 4-' BOULDER .'WALJL `\ 2.2 ' RRQR©,5 SRN a _ tNtSHED-FtCOR=12 +12.3 r:_ f ��\ 12 DIAMETER SDR35 Op Of`rye - EFFLUENT LINE t N +224 14 2_taJJDER WALL �� �� �� ��\� 16 BW- 30, ZIV: 32--- �Q� � �� � �\ � �� �� � �\ �� � NSPECTION PORT NDARkINF7L TRA TOR 80 m PERCOLA 770N TEST RESUL TS - A percolation rate of 30 minutes per inch will be used in he design. The percolation test is based on the data from the design of the system for the main house on the some lot r - z o DESIGN CALCULA DONS a Design percolation rate T = 30 minutes per inch The barn will have one bathroom, with toilet and a sink for washing hands o r Maximum ; dal7y Flow = Qmax Omox = (17oilet x 24.8 gal/day + 1Lavotory x 8.4 gal/day + 1Both/shower x 14.7 gol/day) x 1507. Qmax = 72 gpd i SEP77C TANK V = Omoxf24hrs x 30 hrs V = 90 gallons Minimum size required by ECEH is 750 gallon, minimum available is 1000 gallon, Q two compartment precast concrete tank by Copland Concrete or equivalent o ABSORP PON AREA 0 i z A = Omox/5 x %IT A = 9015 x 0 = 99 s f. Based on Applicotio Rate: A = 99 gpd/0.6 gpd/s. f A = 165 s. f. Standard Infiltrator Chamber System in a trench configuration with an allowed 50 percent reduction in the absorption area is recommended. Acorrected = 8.3 s. f. Surface area of one Infiltrator Chamber = 15.5 s. f. ~ Use 6 In filtrotor Chambers in one trench. p W --- A w� No7Fs. Z o 0 0i 1. Bends in the building - sewer shall be limited to 45 degrees. p 2. The septic tank shall be installed level. The tank shall have removable covers or manholes to within 8 P) U Z Z inches of the finished grade, for inspection and cleaning. Q WVO LLj J. Excavate three (3) feet wide trench. v1 Q CL 4. The bottom and the sidewalls of the trenches shall be raked to eliminate smearing. °O` • 5. Assemble and install the Infiltrator Chambers in the trenches according to the manufacturers = Q recommendations. W 6. Bockfili the sidewall area with native on —site soil for proper support. 7. Backfjll the trenches with a minimum of 12 inches of tamped soil cover. 8. Avoid vehicle traffic over the system. 9. All installations shall meet the rules and regulations of the Eagle County Environmental Health Division, -. Chapter 4, Individual Sewage Disposal Systems. 10. The Septic System installation shall be inspected by the Eagle County Environmental Health Department and by the Design Engineer prior to backfilling: rr `• V rn C14 0) o CD co N 00 o .-. U w C-) 0 U v X �~ 3 p w \ CO v00 1000 GALLON CONCRETE SEPTIC TANK �I N � BY COPLAND CONCRETE OR EQUIVALENT U ^1 o CN m .-. TOP YIETf 0 o r- r-----------------i r------------1 ! t 1 1 I I 1 1 t I 1 1 I I i i 1 1 t 1 I I i 1 ! 1 i t 1 1 1 1 I t IL � 1 f i 1 1 ! 1 1 i i 1 1 6"-6 1 t 1 I - t 1 I I t 1 i 1 t 1 1 1 1 ! L----------------- J L----------- J pE SIDE VIEW �Q; 29526 aa 20' p°•q [////'� DRAWN BY L. P. CHECKED BY L.P. PROJECT NGt: 03041 DATE: 04-22-2003 DRAWINC NO. 03041 SD. D WG SHEET 1 OF 1