HomeMy WebLinkAbout101 Casteel Creek Rd - 210519404003INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. ALTERATION PERMIT NO. IS-2194-02 BP NO. 14229 OWNER: DAVE BENBOW PHONE: 303-988-8200 MAILING ADDRESS: 165 SOUTH UNION, SUITE 250, LAKEWOOD, CO 80228 APPLICANT: GLENN PALMER, ALPINE ENGINEERING PHONE: 970-926-3373 SYSTEM LOCATION: 2102 WEST LAKE CREEK RD., EDWARDS, CO TAX PARCEL NO. 2105-194-04-001 LICENSED INSTALLER: LONG'S EXCAVATION, JERRY McARTHUR LICENSE NO.34-02 PHONE: 970-949-4682 DESIGN ENGINEER: ALPINE ENGINEERING, GLENN PALMER PHONE NO. 970-926-3373 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 4 BEDROOM RESIDENCE EXISTING 1250 GALLON SEPTIC TANK, 1519 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 49 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN REVISIONS DATED 5/28/02. THE EXISTING TANK CAPACITY AND THE NUMBER OF COMPARTMENTS IT CONTAINS NEED TO BE VERIFIED THROUGH PUMPING RECORDS. CALL ENVIRONMENTAL HEALTH FOR A SOIL PROFILE OB- SERVATION PRIOR TO OR AT THE TIME OF INSTALLATION. THERE ARE SEVERAL NOTES ON THE FIELD SET OF PLANS THAT NEED SPECIAL ATTEN- TION, SPECIFICALLY THE ONE THAT IS HIGH -LIGHTED REGARDING THE OLD LEACH FIELD BE SURE TO MAINTAIN ALL APPLICABLE SETBACK RE- QUIREMENTS. RAKE ALL TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS, AND DO NOT INSTALL IN WET WEATHER CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER FOR FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION, OR WITH ANY QUESTIONS REGARDING THE INSTALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROV DATE: JUNE 4, 2002 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1488 SQUARE FEET (VIA 49 TMFTT.TRAT(-g IJNTTS ) INSTALLED CONCRETE SF.PTTC TANK: 1 non GALLONS IS LOCATED DEGREES AND 2 FEET INCHES FROM THE CLEAN —OUT NEAR THE OD TANK COMMENTS: THE FINAL INSPECTION WAS DONE BY THF. DFRTGN FNCTNFFR nN IQ.j?fn9THE ENGINEER'S FINAL CERTIFICATION AND AS —BUILT DRAWING WERE RECEIVED ON 10/ /02 THIS SYSTEM TR LARGE ENOUGH FOR A 4 BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROV DATE: OCTOBER 16, 2002 FEB- i9-2002 0`3: 551-1 FF OUM:.tHULt LUUN i r Cw~ naN = i U_: — �• � • Ins 7plete Applications Will NOT Be Accepted (Site Plan MUST be attached) % q / ISDS Permit # Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 Eagle (970)328-8755, Fax (970)328-0349, E1 Jebel (970)927-3823 FEE SCHEDULE * APPLICATION FEE $350.00 * THIS FEE INCLUDES THE ISDS PERMIT, SITE EVALUATION (PERCOLATION TEST, * SOIL PROFILE OBSERVATION) AND FINAL INSPECTION * ADDITIONAL FEES MAY BE CHARGED IF A REINSPECTION IS NECESSARY, OR A * PRE -CONSTRUCTION SITE VISIT OR CONSULTATION IS NEEDED * REINSPECTION FEE $47.00, PRE -CONSTRUCTION SITE VISIT FEE $85.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" we'v PH. �03 -9g8- gz�7 PROPERTY OWNER: MK DQVE 1 p 3n3 tjBg 573 cloAcvtillc�AFI- R3aArcD �vu4c PHONE: S13-57-:50 2D MAILING ADDRESS: S. lJlVlb/`i r Sv ITG` Z - L4YEx/GvDj C0 gO220 PHONE: APPLICANT/CONTACT PERSON: G,t Nov vA rnF` C6.M) LICENSED SYSTEMS CONTRACTOR: � , F_�-X PHONE: 970 ' c%LII q/a87- COMPANY/DBA: ADDRESS: PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description. LOT tD Z , A. �E S0 r3 O P CoT 10 , NEW yy �� M TO P?:0 Tax Parcel Number : �C� - 1 � - 1 _6 0 ) Lot Size. 15. S66 AC. Physical Address: 2(OZ Gv�T CA�Gf : tE °� DSO BUILDING TYPE: (Check applicable category) Number of Bedrooms Residential/Single Family Number of Bedrooms ( ) Residential/Multi-Family ( ) Commercial/Industrial* Type *These systems require design by a Registered Professional Engineer TYPE OF WATER SUPPLY: (Check applicable category) (�) Well ( ) Spring ( ) Surface ( ) Public Name of Supplier: ✓✓�� f APPLICANT SIGNATURE: Y n Date: 6a�lb e AID:V RECEIPT #: T /v� AMOUNTP CHECK #: d CASHIER: DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO October 16, 2002 Raymond P. Merry, REHS Director Dave Benbow 165 South Union, Suite 250 Lakewood, CO 80228 RE: Final of ISDS Alteration Permit #2194A-02, Tax Parcel #2105-194-04-001. Property location: 2102 West Lake Creek Rd., Edwards, CO. Dear Mr. Benbow: This letter is to inform you that the above referenced. ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Eagle County Environmental Health Department ENCL: Informational Brochure Final ISDS Permit cc: files OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO Date: June 4, 2002 TO: Long's Excavation Raymond P. Merry, REHS Director FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Permit #2194A-02. Tax Parcel #2105-194-04-001. Property Location: 2102 West Lake Creek Rd., Edwards, CO., Benbow residence. Enclosed is your ISDS Alteration Permit #2194A-02. Please obtain a field copy of the engineer design stipulated on the permit from the engineer. It is valid for 120 days, or for the duration of your current building permit for this property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer, and views the installation. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files Alpine Engineering, Glenn Palmer OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 /' Qp REG/5�� oQ�.•'®. P42''•'�1 OCT 9 2002 �:�� 22753 ENVIRONMENTAL ENGINEERING INC. � Alpine Engineering. Inc./P.O. Box 97/Edwards, Colorado/81632/970-926-3373/FAX 90 7 .zc;v?- FACSIMILE TRANSMISSION al�ff»i PINE D ATE: I iD 1°a- 12-oe;q IJOB T TLE: i'J�h1 PAD IiV DES ► D ►u C - �� (Nome IrAllrzft �VCI l e i GG' Lt��v rn e: k<✓w _ r� ,Company: ��bL C. H Company. Company- IFax: Fax: Fax: t Name: Marne: Name: Company: Company. Company. Farr Fax: Fox: iNuMba., of pages (including cover sheet) � 61.: �0 A IRENIARKS: PIC -fire Q a-h ev®/v f!'Sfr/ iia o v1 S trr✓ TH C to � L. r. , T eft P�'i r2 b 7Z7 NL-"l� q y G o na , fL. M S 9L�r P T-K n F Y�, v tZ I/ v ry I iv e= / L TV 6 M.tS • Ai -rep J:�,-e- I - I, S t Gv TN 7-H TW PF IIVFlt nt /t l-vit n e & `1,-v► ti 1crij r i 4, LOJG S kDCC •-r g"TV-f\cTOr?-- sA-Ih r/tAr r>tr FtLL0 '1.1/A-r Cyy"yc—VA�11-1I 1 e I~YL- ' 2L) I, V V �i'A DES C,0WF' t 2- Aj FA-A4 SUT ; t1c S . n r. r- IL w !ail I✓ , r tr-i .t a' .. u r I n�>~, c �-I2sF'ro �p -•- Pig- wv-r � S !N t, 1 A- t✓vf'!S I PST 1~ N C- ® y Al.t`I'-Ev UDO Low6seyc Ippov v cr NCq- •r)iE p AS0—,VLLT— Al i o 01/4 5 r;`i%` li I c �a NF/ rvn tNP5 5 spjp�4 C119E --tv6M5- I5 A)C 00,0M JIVAIL5. 15 /¢ r r A uc- ur uc ic:eop HErint tnul"LLKlnb zi-ruzie-b:i:i-r;i p.1 P) m ENGINEERING INC. D a��q� 0 P9' t d 22753 �0! Alpine Engineering, lac./P.O. Box 97/Edwords, Colorado%81632/970-926-3373%rA.` I 90 - --- FACSIMILE TRANSMISSION DATE -- o I Z �, JOB TITLE: f3 r�! P�UW Quest [>tveE"' I %r 4r 3'ti i' eu ....:�_ e: GG 't L C�tg °� ? me: t�U _ f (IName: 3Company: Company- Company. II Far: i rox! 11 Fox: (Name: tame: Name: Company: Company- Company. Fox: Fax: Fox: INumbar of pages (including corer sheet) REMARKS: P-c4VW '1 � i'- k4e is &W!° -rite Cmm 62 pcwgsp IV `-FJf::� V t an> t2-1-r rC s C7 P r=tom ! �GtrtrD� 6�fs ` i P. -r G n unAj 9t"eTU.- l C z ars j PL,PT"R VF t'�v .y rary rMFfs &1-P2S id PL- w rN rt�- rr�� mot= r��rt r-n�rr�� � e ram` �a r ���•��-. - t t_. r 5' �-YC — 6 "T'tM- C -[V e to kA *T- t is {Ir LP I'V &g EL-4 !k 161 'Vvtwct t Vi Tl i tA&"I co, r `X 't : 1Q tt -AV`l, FV IPi CP(?(+ i r !a E L-' " If 1 :' hA! l L N L. A *T e£�ULt}E`YL. ��r.. _ +� "A16 S i 7" •i�C - W 5 �._ nn!`r . 4 . . ...... .... z I �o f 9W T NggM T nMq -IM T A-iH dqP': P T ;7n ,-n a.an P NE EM ENGINEERING INC. Alpine Engineering, Inc./P.O. Box 97/Edwards, Colorado/81632/970-926-3373/FAX 970-926-3390 FACSIMILE TRANSMISSION (DATE: J3f 1pZ IJOB TITLE: N�LrI Name: L q vvA Fgvice % Name: Name: Company. Company. Company. Fax: Fax: Fax: Name: Name: Name: Company. Company. Company. Fox: Fax: Fox: PI{�� ENGINEERING INC. Alpine Engineering, Inc./P.O. Box 97/Edwards, Colorado/81632/970-926-3373/FAX 970-926-3390 TRANSMITTAL - DATE: JOB TITLE: Name: �� Name: Name: i Company- Company. Company. Fax: Fax: Fax: lName: Name: Name: Company. Company. Company. Fax: Fax: Fax: (Number of pages (including cover sheet) REMARKS: �! �r` M1 REGEIVED 82 NOV 4 2002�,Y::NT�,L ENVIBONIMENTAL HEALTH DEPARTMENT ALPINE ENGINEERING, INC. • ALPINE ENGINEERING, INC. May 6, 2002 Mr. Bill Carlson Eagle County Health Department P.O. Box 179 Eagle, Co 81631 Re: Lot 10.2, Lake Creek, Benbow Residence �p,00 RFG�S O U. P. >' �Ovv�`je1 Ica 22753 s Introduction: A 3 bedroom cabin was constructed in the late 1970's, on Lot 10.2 a resubdivision of Lot 10, New York Mountain Project, Eagle County Colorado. The site is adjacent to west Lake Creek Road and accessed from Casteel Creek Road (which intersects west Lake Creek Road approximately 200 yards south of the Baryeta Trail Head, 2102 west Lake Creek Road. It is my understanding that the owner's representative (Ken Harkias of Trends West) visited Eagle County Health Department in the Fall of 2001 and that an ISDS permit was issued for the construction of the existing septic system. The permit indicated a 1,250 gallon septic tank (verify) and absorption trench sized fo 3 bedrooms using the A = Q/S)4'r (percolation rate) basis (600 SF). 1j, i9 Proposed Constructio . A new bedroom is to be added to the existing 3 bedroom house (for a total of 4 bedrooms). The new bedrooms will displace the existing 2 car garage attached to the existing cabin so a new garage (no living space or plumbing) is proposed to be constructed approximately 60 feet north of the existing house. The existing absorption trench appears.to be a gravel system: I'm not sure it's a bed or trench configuration. The existing absorption area was encountered on the edge of the soil profile hole excavation (TP-2, Nov. 5, 2001), and had approximately 3' of cover (soil) over the top of gravel. Soil Profile Hole: Two soil profile holes were dug on Nov. 5, 2001; TP-1 was approximately 40' above the existing and proposed absorption area; TP-2 was adjacent to the existing and proposed absorption area. Koechlein Engineering was on site to observe the test pits, and the test pit logs are attached. The logs show that approximately 1 R. of top soil was found over sandy silts. No groundwater was encountered at the time of excavation, and no soil mottling existed to indicate seasonal changes in the groundwater table. Percolation Tests and Application Rate: 3 percolation tests were performed on Nov. 5, 2001, ranging from 12 to 18 minutes per inch. Based upon the soil type and percolation rate, an application rate of .6gpd/sf was used. Sewage Generation: 4 bedrooms x 2 persons/bedroom x 75gpd/person x 150% = 900gpd Edwards Business Center • P.O. Box 97 • Edwards, Colorado 81632 • (970) 926-3373 • Fax (970) 926-3390 pep Ua Ue 11:-tea HLVIM:9 tl'IblMLLKINU Jf[JJeEi;i:jf:j P. Ile �� f ,% r. Ass um edfespprQx. location 160 of e i$tng field, vIANIWCpv 98.0r .. r.. &ali tic spno Addit ro � F i ,,,.• .rr ,�,r.ea4S .... +�.' 'e � X Exist.r Gravel Drive �4 � J r�� r � �- —�' �'"' �^^ `ti+ _ �� .Y�, � � r � � y ....r .,os .w� 'ram J;y/•�, f +" �, � .r� r� '� r �y! '�� �s .f°� 1 �� r+ �•• +'17�.+'�� —� �... TwwW+�pp ,W awe rs n.r+wr,..,....r ..r � � w+P � � � (/ � � _ ✓ � "'�-� a rT .sue •�' .r rr. �` r�w. �s -�v �. _� �. ^,� :rr � �!' f+ r���Ar'� rriY� � a�� J �r ter. r,� �r �� s �� �� Of , ,, A - n ,, —A -r r. _ —I - - - - . — oep it uc 11:uua nL-rint tnUlnttK111U u-/uzie-bid-fj P. 1 ENGINEERING INC. Alpine Engtneering, tnc./P.Q. Box 97/Edwards, Colorado/81632/970-926•-3373/FAX 970-926-3390 FACSIMILE TRANSMISSION DATE: 9' JOB TI TLE:+t Nome: 1,r 6gvC,-f Nome. � � Name: cort,pany��i sd Company. Gty1 Company- { Fax: Fax: Fax: j tNome: Name: Name: Company. Company. Company. Fox: Fox: Fox: Number of pages (including cover shee,) REMARKS: r LA1,4X r ke afv�.. j rt rrn 4 -7 ^1rMnIn 'YI Ir 11 !'t.. Cf ^m Tn. r-nf-1 r rnl Ik ITV rk 11 1 Llr7nl TLJ O,l,.=. +1 it UC 1 1: U 1 a HL.r 119t LnU I MLLK 1 MU :J"/uz i:!bj 3 /;3 kf5 6 Fflu A)p CRW 1,pv 5 Gt rlo "� fV // flVE MAt L �1149,0111AZ z z -ro 4 � 4 r W/Itc HEI&H r w ornc fow W. 1^_CIll 4 -7 - ifw11, ^I TI Ir 4 M . CM^" 7M M. r^ 1 r P'- IL mkI ILL II I 1 1-1 - I ziep Uo uG 1 1 : ft 1 a HLr 111L ti` b l MLLK I nb U-1UUebJJ'/U P. 1 AaP MI IN 1E ENGiNEERiwrIG tNC. . Alpine Engineering, Inc./P.O. Box 97/Edwards, Coiorodo/81632/970-926--3373/FAX 970-926-3390 FACSIMILE TRANStiSSION I fl ATE: cj -5 - DZ JJOf TITLE: Br--lole ec_ - 192! Nome: I.avro 'FGl'L1fce* me: in I.3A, Vvv" Na i Compony: Company. Company. r i Fax: .► Fox: k .155 . Fax: Name: Name: Home., Compony. Company Company. Fox: Fox: Fax: Number of pages (including cover sheet) RENIARKS: w1 �'Str1►t� 1 b !R ►�Ga r,,•, 15 r �'" 6 Ott se 0 .y4,�,. �i/�«} J�y � (e* Pit, The e t 7'. t r -(a eee r® U r t r �. Oi05 1 �. ff !1� X f If `' rbwA ♦ C low be*-7%tgft 602ems wyrj l- /sT efi'PjF'0 wry p `-� ( s' It 1 i rlrm C llmm '1 T1 11 1 4 4 . A 4 ^K4 T M . rh!'9 r !`rll 1k ITV rL 11 1 1_ Ir(11 TI_I OFt(_^C . 4 (. k L r� o ISDS PERMIT #) ?'4- 02 /u o Perc�- PERCOLATION TEST EAGLE COUNTY ENVIRONMENTAL HEATLH � .OWNER:_ �A�� 'PHSYSICAL ADDRESS: -I1 o X Uses-} L e-Sm z C,c e- LEPAL DESCRIPTION: Le 4- I0,a -, , x v s ,, ►a o �6 � W , �Jekj ` of v\ MMAAJLING ADDRESS: am\;ewoe E'DF DWELLING: ke AD.: NUMBER OF BEDROOMS: TPST HOLES PRE-SOAKED: YES NO SOIL TIME WATER DEPTH INCHES OF FALL RATE PROFILE TIME TO DROP LAST INCH: PERC RATE: MINIMUM LEACH FIELD SIZE: MINIMUM SEPfTIC TANK SIZE: V0 b,�tc,c h os �+rGJvJwix �cr e.A 91 Zesii��2 COMMENTS: So i L < le a e) N X'k V, r-c e r K (� i G 1 ` F, e (j P a J N 6i� �P /� A a P n! ,T 1 e S C h CJ I) 1( C J n! t N? #t7 �vMN e4lC��c,N�� c9:Jt IQSICPC i�0�4� G{ 15d ti NY'fcgvn+tvL I ENVIRONMENTAL HEALTH SPECIALIST DATE _i Vi Edwards Business Center • R Box 97 • Edwards, Colorado 81632 • (970) 926-3373 • Fax,(970) 926-3390 KOECHLEIN CONSULTING ENGINEERS, INC. Consulting Geotechnical Engineers x ` t t-����aflnr J. -7v NOT TO SCALE VICINITY MAP [>s•,6i JOB NO. 01-185 FIG. 1 L.OIIau1•n.p - PROPOSED 6AFAGE kk LvtAnc ;'�'1 ilk i ell i j ; '� 1 =gx 1. t AEA 6 ,1! i M LOT 10.2 _ = 1 15.866 acres e no' ow 1"=60• a 'r't'r g a- 1=ifY 6101• SB6�6'?Y[ II99.J9' . LOCATIONS OF EXPLORATORY TEST PITS �SoIL -tL� F J08 NO. WAS5 TP-1 -0 WC=9 DD=101 WC=19 5 -200 = 81 �10 LEGEND: TP-2 ® TOPSOIL 15 SILT, Sandy Scattered gravel and cobble, Dry to slightly moist, a ium dense, Brown. a HAND DRIVE SAMPLE. Indicates 2.0 inch diameter brass liner w driven into the soil by a hammer. w u_ Z 20 BULK SAMPLE. Obtained from backhoe cuttings. -- Ir- a - —. w 0 Notes: 1. Exploratory test pits were excavated on November 5, 2001 using a rubber -tired backhoe. 2. No free ground water was encountered at the time of excavating. 3. The Test Pit Logs are subject to the explanations, limitations, and conclusions as contained in this report. 4. Laboratory Test Results: WC - Indicates natural moisture (%) DD - Indicates dry density (pcf) -200 - Indicates percent passing the No. 200 sieve M 5. Approximate elevations are based on the Topographic Map prepared by Meyer Land Systems, dated October 19, 2001. LEGEND OF EXPLORATORY TEST PITS LOGS OF EXPLORATORY TEST PITS N 5 10 15 5 40 i JOB NO. 01-185 FIG. TABLE 7-2 RECOMMENDED RATES OF WASTEWATER APPLICATION FOR TREN'H AND BED BOTTOM AREAS (4)(11)(121a Percol ati or, Application Soil Texture — Rate Rateb min/in. gpd/ft2 Gravel, coarse sand <1 Not suitablec Coarse to medium sand 1 - 5 1.2 Fine sand, loamy sand � Sand 1 oam, loam 6 - 16 - 15 30 0.8 Loam, pc. -ous silt 1 ca.n 31 - 60 0.45 Silty clay loam, clay loamd F1 - 120 0.2e a May be suitable estimates for sidewall infiltration rates. b Rates based on septic tank effluent from a domest`c waste source. A factor of safety may be desirable for w-istes of significantly different character. c Soi 1 s with pert-il ati on rates <1 min/in. can be used if the soil is replaced with a suitably thick (>2 ft) layer of loamy sand or sand. d Soils without expandable clays. e 1 hese soils may be easily damaged during constructi un. 214 SOILS AND FOUNDATION INVESTIGATION PROPOSED BENBOW CABIN LOT 10.2 2102 W. LAKE CREEK ROAD NEW YORK MOUNTAIN PROJECT EAGLE COUNTY, COLORADO Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy • Suite 115 • Lakewood, CO 80228-2845 LAKEWOOD AVON SILVERTHORNE (303) 989-1223 (970) 949-6009 (970) 468-6933 (303) 989-0204 FAX (970) 949-9223 FAX (970) 468-6939 FAX KOECHLEIN CONSULTING ENGINEERS, INC. CONSULTING GEOTECHNICAL AND MATERIALS ENGINEERS SOILS AND FOUNDATION INVESTIGATION PROPOSED BENBOW CABIN LOT 10.2 2102 W. LAKE CREEK ROAD NEW YORK MOUNTAIN PROJECT EAGLE COUNTY, COLORADO Prepared for: Ken Harkias Trends West, Inc. P.O. Box 2382 Edwards, CO 81632-2382 Job No. 01-185 November 13, 2001 DENVER: 12364 West Alameda Prkwy., Suite 135, Lakewood, CO 80228 (303) 989-1223 AVON. (970) 949-6009 SILVERTHORNE. (970) 468-6933 November 13, 2001 Job No. 01-185 KOECHLEIN CONSULTING ENGINEERS, INC Consulting Geotechnical Engineers TABLE OF CONTENTS SCOPE I EXECUTIVE SUMMARY I SITE CONDITIONS 2 PROPOSED CONSTRUCTION 3 INVESTIGATION 4 SUBSURFACE CONDITIONS 4 RADON 5 EXCAVATIONS 5 GROUND WATER 6 FOUNDATION 7 FLOOR SLABS 8 FOUNDATION DRAINAGE 9 LATERAL WALL LOADS 9 RETAINING WALLS 10 SURFACE DRAINAGE 11 IRRIGATION 11 COMPACTED FILL 12 LIMITATIONS 13 VICINITY MAP Fig. 1 LOCATIONS OF EXPLORATORY TEST PITS Fig. 2 LOGS OF EXPLORATORY TEST PITS Fig. 3 LEGEND OF EXPLORATORY TEST PITS Fig. 4 GRADATION TEST RESULTS Fig. 5 SWELL -CONSOLIDATION TEST RESULTS Fig. 6 TYPICAL WALL DRAIN DETAIL Fig. 7 TYPICAL RETAINING WALL DRAIN DETAIL Fig. 8 $ November 13, 2001 Job No. 01-185 5 KOECHLEIN CONSULTING ENGINEERS, INC. Consulting Geotechnical Engineers SCOPE This report presents the results of a soils and foundation investigation for the proposed Benbow cabin to be located on Lot 10.2, a resubdivision of Lot 10, in the New York Mountain Project in Eagle County, Colorado. The approximate site location is shown on the Vicinity Map, Fig. 1. The purpose of this investigation was to evaluate the subsurface conditions at the site and to provide geotechnical recommendations for the proposed structure. This report includes descriptions of subsurface soil and ground water conditions encountered in the exploratory test pits, recommended foundation systems, allowable bearing capacity, and recommended design and construction criteria. This report was prepared from data developed during our field investigation and our experience with similar projects and subsurface conditions in the area. The recommendations presented in this report are based on a residential cabin being constructed on the lot. We should be contacted to review our recommendations when final plans for the structure have been completed. A summary of our findings and conclusions is presented below. EXECUTIVE SUMMARY 1. The subsurface conditions encountered in the exploratory test pits were similar. The subsurface conditions consisted of up to 1.0 foot of topsoil underlain by a medium dense, sandy silt with scattered gravel and cobble to the maximum depth explored of 8.0 feet. Laboratory test results November 13, 2001 KOECHLEIN CONSULTING ENGINEERS, INC. Job No.01-185 Consulting Geotechnical Engineers indicated that the sandy silt has a very low to low collapse potential when wetted. 2. Topsoil to a depth of 1.0 foot was encountered at this site. Greater depths of topsoil could be encountered throughout the site. The topsoil will need to be removed from all construction areas prior to construction. The topsoil may be used in landscaping areas. 3. At the time of this investigation, no free ground water was encountered in the exploratory test pits to the maximum depth explored of 8.0 feet. 4. We anticipate that the subsurface conditions at the proposed foundation elevation will consist of sandy silt with scattered gravel and cobble. In our opinion, the natural sandy silt will support spread footings for the proposed cabin. Refer to the FOUNDATION section of this report for more details. 5. The subsurface conditions encountered at the proposed floor slab elevation consisted of the natural sandy silt. In our opinion, slabs -on -grade may be constructed on the natural sandy silt with a low risk of movement. Refer to the FLOOR SLABS section of this report for more details. 6. Open cuts and excavations require precautions as outlined in this report in order to maintain the stability of slopes and sides of excavations. 7. In our opinion conventional construction equipment will be capable of completing the necessary excavations. 8. Drainage around the cabin should be designed and constructed to provide for rapid removal of surface runoff and avoid concentration of water adjacent to foundation walls. 9. The potential for radon gas is a concern in the area. Building design should include ventilation systems for below grade areas such as crawl spaces and basements. SITE CONDITIONS The proposed cabin will be located on Lot 10.2, a resubdivision of Lot 10, in the 2 November 13, 2001 KOECHLEIN CONSULTING ENGINEERS, INC Job No.01-185 Consulting Geotechnical Engineers New York Mountain Project in Eagle County, Colorado. The lot is accessed by a gravel road, which borders the western boundary of the site. A ditch is located to the west of the existing gravel access road above the site. An existing residence is located approximately 60 yards to the south of the proposed cabin site. Two ponds are located down towards the northeast of the proposed cabin. The cabin site is bordered on the west side by a gravel driveway, which loops around to the north and provides access to the lower east side of the cabin site. The site slopes down towards the east at an approximate grade of 30 to 40 percent. Vegetation on the lot consists of grasses, bushes, weeds, aspen trees and pine trees. PROPOSED CONSTRUCTION At the time of this investigation, plans for the proposed cabin were not available. We anticipate that a two-story residential cabin with a walkout basement and slab -on - grade floors will be constructed on this site. We believe that the cabin will be of cast -in - place concrete and wood frame construction. We anticipate that excavations of 8 feet will be necessary for construction of the proposed cabin. Maximum column and wall loads were assumed to be those normally associated with residential structures. 3 1 November 13, 2001 Job No. 01-185 KOECHLEIN CONSULTING ENGINEERS, INC Consulting Geotechnical Engineers INVESTIGATION Subsurface conditions were investigated at this site on November 5, 2001, by excavating two exploratory test pits with a rubber -tired backhoe at the locations shown on • the Locations of Exploratory Test Pits, Fig. 2. An engineer from our office was on the site to observe the excavating of the exploratory test pits and visually classify and document the subsurface soil and ground water conditions. A description of the subsurface soils observed in the exploratory test pits is shown on the Logs of Exploratory Test Pits, Fig. 3, and on the Legend of Exploratory Test Pits, Fig. 4. Representative soil samples obtained from the exploratory test pits were tested in our laboratory in order to determine their natural moisture content, gradation properties and swell -consolidation properties. The results of the laboratory tests are presented on the Logs of Exploratory Test Pits, Fig. 3, on the Gradation Test Results, Fig. 5, and on the Swell -Consolidation Test Results, Fig. 6. SUBSURFACE CONDITIONS The subsurface conditions encountered in the exploratory test pits were similar. The subsurface conditions consisted of up to 1.0 foot of topsoil underlain by a dry to slightly moist, medium dense, sandy silt with scattered gravel and cobble to the maximum depth explored of 8.0 feet. The sandy silt became more dense with depth. El November 13, 2001 KOECHLEIN CONSULTING ENGINEERS, INC Job No. 01-185 Consulting Geotechnical Engineers Laboratory test results indicated that the sandy silt has a low collapse potential when wetted. At the time of this investigation, no free ground water was encountered in the exploratory test pits to the maximum depth explored of 8.0 feet. In recent years, radon gas has become a concern. Radon gas is a colorless, odorless gas that is produced by the decay of minerals in soil and rock. The potential for radon gas in the subsurface strata of mountain terrain is likely. Since excavations for lower levels in the cabin are anticipated, we suggest that the building be designed with ventilation for below grade areas. EXCAVATIONS We anticipate that excavations up to 8 feet in depth will be required for construction of the proposed cabin. Based on the subsurface conditions, it is our opinion that conventional construction equipment will be capable of completing the necessary excavations. Care needs to be exercised during construction so that the excavation slopes remain stable. The subsurface soil, which consisted of a sandy silt with scattered gravel and cobble, classifies as Type B soils in accordance with OSHA regulations. OSHA 5 • November 13, 2001 Job No. 01-185 KOECHLEIN CONSULTING ENGINEERS, INC. Consulting Geotechnical Engineers regulations should be followed in all excavations and cuts. Approximately 1.0 foot of topsoil was encountered in the exploratory test pits. Greater depths of topsoil could be encountered throughout the site. All topsoil beneath the proposed construction should be removed. The topsoil may be used in landscape areas. Backfill should be placed and compacted as recommended in the COMPACTED FILL section of this report. GROUND WATER At the time of this investigation, ground water was not encountered in the exploratory test pits to the maximum depth explored of 8.0 feet. Based on the conditions exposed within the test pits, we do not anticipate that ground water will adversely affect the construction of the proposed cabin. However, our investigation was performed during a dry time of the year. It is possible that ground water may be encountered during wetter times of the year. If ground water is encountered within excavations for the cabin, the ground water can typically be controlled by shallow trenches on the outside of the foundation for the cabin. The shallow trenches should be sloped down to a sump pit, where the water can be removed by pumping or to a gravity outlet. If ground water is encountered within the excavation for the cabin, we should be contacted to provide specific recommendations at that time. Col f November 13, 2001 KOECHLEIN CONSULTING ENGINEERS, INC. Job No.01-185 Consulting Geotechnical Engineers FOUNDATION The subsurface conditions at the foundation elevation consist of the sandy silt with scattered gravel and cobble. In our opinion, the proposed cabin may be supported by a spread footing foundation system bearing on the natural sandy silt. We recommend that the spread footing foundation system be designed and constructed to meet the following criteria: 1. Footings should be supported by the natural sandy silt or compacted fill. All existing topsoil should be removed prior to construction of the foundations. All footings should extend at least 3 feet below the existing natural ground surface. 2. We recommend wall and column footings be designed for a maximum allowable soil bearing pressure 2,000 psf. 3. The base of the exterior footings should be established at a minimum depth below the final exterior ground surface, as required by the local building code. We believe that the depth for frost protection in the local building code in this area is 3.5 feet. 4. " We anticipate that scattered cobbles could be encountered at the foundation elevation. Removal of the cobbles may result in depressions and rough bottoms in the excavation. The resulting depressions can be backfilled with compacted backfill or lean concrete. 5. Column footings should have a minimum dimension of 24 inches square and continuous wall footings should have a minimum width of 16 inches. Footing widths may be greater to accommodate structural design loads. 6. Continuous foundation walls should be reinforced to span local anomalies in the soil. 7. Fill should be placed and compacted as outlined in the COMPACTED FILL section of this report. We recommend that a representative of our VA a November 13, 2001 KOECHLEIN CONSULTING ENGINEERS, INC- Job No.01-185 Consulting Geotechnical Engineers office observe and test the placement and compaction of structural fill used in foundation construction. It has been our experience that without engineering quality control, poor construction techniques can occur which result in poor foundation performance. 8. A representative of our office must observe the completed foundation excavation. Variations from the conditions described in this report, which were not indicated by our test pits, can occur. The representative can observe the excavation to evaluate the exposed subsurface conditions. FLOOR SLABS The subsurface soils at the floor slab elevations consisted of topsoil or natural sandy silt. The topsoil is not suitable for support of slab -on -grade floors. In our opinion, the sandy silt may support slabs -on -grade with a low risk of movement. We recommend the following precautions for the construction of slab -on -grade floors: 1. Slabs may be placed on the natural sandy silt or compacted fill. All topsoil beneath slabs -on -grade should be removed prior to construction of floors. 2. We anticipate that scattered cobbles could be encountered at the floor slab elevations. The removal of cobbles may result in depressions and rough bottoms in the excavation. Fill may be placed and compacted beneath the slabs -on -grade to fill in depressions and act as a leveling course for the slabs. 3. Frequent control joints should be provided in all slabs to reduce problems associated with shrinkage. 4. Fill beneath slabs -on -grades may consist of on -site soils free of deleterious material or approved fill. Fill should be placed and compacted as recommended in the COMPACTED FILL section of this report. Placement and compaction of fill beneath slabs should be observed and tested by a representative of our office. November 13, 2001 Job No. 01-185 KOECHLEIN CONSULTING ENGINEERS, INC Consulting Geotechnical Engineers FOUNDATION DRAINAGE Surface water, especially that originating from snowmelt, tends to flow through relatively permeable backfill typically found adjacent to foundations. The water that flows through the fill collects on the surface of relatively impermeable soils occurring at the foundation elevation. Both this surface water and possible ground water can cause wet or moist below grade conditions after construction. Since we anticipate below grade areas, we recommend the installation of a drain along the below grade foundation walls. The drain should consist of a 4-inch diameter perforated pipe encased in free draining gravel and a manufactured wall drain. The drain should be sloped so that water flows to a sump where the water can be removed by pumping, or to a positive gravity outlet. Recommended details for a typical foundation wall drain are presented in the Typical Wall Drain Detail, Fig. 7. LATERAL WALL LOADS We anticipate that walls will be planned which may require lateral earth pressures for design. Lateral earth pressures depend on the type of backfill and the height and type of wall. Walls, which are free to rotate sufficiently to mobilize the strength of the backfill, should be designed to resist the "active" earth pressure condition. Walls, which are restrained, should be designed to resist the "at rest" earth pressure condition. Basement walls are typically restrained. The following table presents the lateral wall W November 13, 2001 Job No. 01-185 KOECHLEIN CONSULTING ENGINEERS, INC Consulting Geotechnical Engineers pressures that may be assumed for design. Earth Pressure Condition Equivalent Fluid Pressure' (pcf) Active 35 At -rest 50 Passive 300 Notes: 1. Equivalent fluid pressures are for a horizontal backfill condition with no hydrostatic pressures or live loads. 2 A coefficient of friction of 0.3 may be used at the base of footings to resist lateral loads. Backfill placed behind or adjacent to foundation walls and retaining walls should be placed and compacted as recommended in the COMPACTED FILL section of this report. Placement and compaction of the fill should be observed and tested by a representative of our office. RETAINING WALLS Due to the slope of the lot, it is possible that retaining walls may be constructed for the proposed project. If retaining walls are to be constructed, in order to reduce the possibility of developing hydrostatic pressures behind retaining walls, a drain should be constructed adjacent to the wall. The drain may consist of a manufactured drain system and gravel. The gravel should have a maximum size of 1.5 inches and have a maximum of 3 percent passing the No. 200 sieve. Washed concrete aggregate will be satisfactory for the drainage layer. The manufactured drain should extend from the bottom of the 10 Y November 13, 2001 KOECHLEIN CONSULTING ENGINEERS, INC Job No.01-185 Consulting Geotechnical Engineers retaining wall to within 2 feet of subgrade elevation. The water can be drained by a perforated pipe with collection of the water at the bottom of the wall leading to a positive gravity outlet. A typical detail for a retaining wall drain is presented in the Typical Retaining Wall Drain Detail, Fig. 8. SURFACE DRAINAGE Reducing the wetting of structural soils and the potential of developing hydrostatic pressure behind below grade walls can be achieved by carefully planned and maintained surface drainage. We recommend the following precautions be observed during construction and maintained at all times after the cabin is completed. 1. Wetting or drying of the open excavation should be minimized during construction. 2. All surface water should be directed away from the top and sides of the excavation during construction. 3. The ground surface surrounding the exterior of the cabin should be sloped to drain away from the building in all directions. We recommend a slope of at least 12 inches in the first 10 feet. 4. Backfill, especially around foundation walls, should be placed and compacted as recommended in the COMPACTED FILL section of this report. IRRIGATION Sprinkler systems installed next to foundation walls or sidewalks could cause consolidation of backfill below and adjacent to these areas. This can result in settling of November 13, 2001 Job No. 01-185 KOECHLEIN CONSULTING ENGINEERS, INC. Consulting Geotechnica! Engineers exterior steps, patios and/or sidewalks. We recommend the following precautions be followed: 1. Do not install a sprinkler system next to foundation walls. The sprinkler system should be at least 10 feet away from the cabin. 2. Sprinkler heads should be pointed away from the structure or in a manner that does not allow the spray to come within 10 feet of the cabin. 3. The landscape around the sprinkler system should be sloped so that no ponding occurs at the sprinkler heads. 4. If shrubs or flowers are planted next to the cabin, these plants should be hand watered. a 5. Install landscaping geotextile fabrics to inhibit growth of weeds and to allow normal moisture evaporation. We do not recommend the use of a plastic membrane to inhibit the growth of weeds. 6. Control valve boxes, for automatic sprinkler systems, should be periodically checked for leaks and flooding. COMPACTED FILL Structural fill for this project may consist of the on -site sandy silt with scattered gravel and cobble or approved imported granular fill. The imported fill may consist of non -expansive silty or clayey sands or gravels with up to 30 percent passing the No. 200 sieve and a maximum plasticity index of 10. No cobbles or boulders larger than 6 inches should be placed in fill areas. Fill areas should be stripped of all vegetation and topsoil, scarified, and then compacted. Topsoil may be used in landscape areas. Fill should be 12 November 13, 2001 KOECHLEIN CONSULTING ENGINEERS, INC Job No. 01-185 Consulting Geotechnical Engineers placed in thin loose lifts then moisture treated and compacted as shown in the following table. The recommended compaction varies for the given use of the fill. Recommended Compaction Percentage of the Percentage of the Percentage of the Use of Fill Standard Proctor Modified Proctor Optimum Maximum Dry Maximum Dry Moisture Content Density Density (ASTM D-698 (ASTM D-698) (ASTM D-1557) or D-1557)' Below Structure Foundations 98 95 -2 to +2 Below Slab -On -Grade Floors 95 90 -2 to +2 Utility Trench Backfill 95 90 -2 to +2 Backfill (Non -Structural) 90 90 -2 to +2 Notes: - 1. For clay soils the moisture content should be 0 to +2 percent of the optimum moisture content. For granular soils the moisture' content should be —2 to +2 of the optimum moisture content. We recommend that a representative from our office observe and test the placement and compaction of structural fill. Fill placed below foundations or slab -on - grade floors is considered structural. It has been our experience that without engineering quality control, poor construction techniques can occur which result in poor foundation and slab performance. LIMITATIONS Although the exploratory test pits were located to obtain a reasonably accurate determination of subsurface conditions, variations in the subsurface conditions are always possible. Any variations that exist beneath the site generally become evident during 13 November 13, 2001 KOECHLEIN CONSULTING ENGINEERS, INC Job No.01-185 Consulting Geotechnical Engineers excavation for the structure. Therefore, a representative of our office must observe the completed excavations to confirm that the soils are as indicated by the exploratory test pits and to verify our foundation and floor slab recommendations. The placement and compaction of fill, as well as installation of foundations, should also be observed and tested. The design criteria and subsurface data presented in this report are valid for 3 years from the date of this report. We appreciate the opportunity to provide this service. If we can be of further assistance in discussing the contents of this report or in analyses of the proposed structure from a soils and foundation viewpoint, please contact our office. KOE,F,1t,''CONSULTING ENGINEERS, INC. ������n��Q.�O R FG/,S' ''% 33822 c ��.t'•.11/G3fol ���� YDN A11, �, ```���. Scott B. gwyers, P.E. Project Engineer Reviewed by: William N. Houlette, P.E. Senior Engineer (4 copies sent) 14 KOECHLEIN CONSULTING ENGINEERS, INC. Consulting Geotechnical Engineers Vs 1 V VICINITY MAP NOT TO SCALE JOB NO. 01-185 FIG. 1 A KOECHLEIN CONSULTING ENGINEERS, INC. Consulting Geotechnical Engineers i s ersY1Y • Fnov 1 f1 I AP ROX TE PROPOSED t+ CA, IN SSE 14 qp If F !i t (t' 1 =Z1, i 111 F }1 t LOT 10.2 _ 15.866 acres a F + ga { !s t 97F * { ! pP s a"5*2r c t moo,I _I ._.....i926Y 610➢' ` 58616'27'[ I; 1299.]9• .. ..._ LOCATIONS OF EXPLORATORY TEST PITS JOB NO. 01-185 FIG. 2 �r KOECHLEIN CONSULTING ENGINEERS, INC. Consulting Geotechnical Engineers TP-1 TP-2 0 0 WC=9 DD=101 WC=19 5 -200 = 81 5 10 10 15 15 s w w m m LL 20 20 Z H a m m w m 25 25 30 30 35 35 40 40 LOGS OF EXPLORATORY TEST PITS JOB NO. 01-185 FIG. 3 KOECHLEIN CONSULTING ENGINEERS, INC. Consulting Geotechnical Engineers LEGEND: ® TOPSOIL SILT, Sandy, Scattered gravel and cobble, Dry to slightly moist, Medium dense, Brown. HAND DRIVE SAMPLE. Indicates 2.0 inch diameter brass liner driven into the soil by a hammer. BULK SAMPLE. Obtained from backhoe cuttings. Notes: 1. Exploratory test pits were excavated on November 5, 2001 using a rubber -tired backhoe. 2. No free ground water was encountered at the time of excavating. 3. The Test Pit Logs are subject to the explanations, limitations, and conclusions as contained in this report. 4. Laboratory Test Results: WC - Indicates natural moisture M DD - Indicates dry density (pcf) -200 - Indicates percent passing the No. 200 sieve (%) 5. Approximate elevations are based on the Topographic Map prepared by Meyer Land Systems, dated October 19, 2001. LEGEND OF EXPLORATORY TEST PITS die JOB NO. 01-185 FIG. 4 KOECHLEIN CONSULTING ENGINEERS 6 inNn 100 #4 0 #20 #30 #4 #iffl -'AD #200 0 90 10 80 20 70 (9 30 -p z 60 m x 40 m a z 50 Z 50 X w 40 m D 60 w o z m 30H O 70 20 80 10 90 0 100 200 100 10 1 0.1 0.01 0.001 DIAMETER OF PARTICLE IN MM + 3" GRAVEL SAND SILT CLAY Sample of SILT, Sandy GRAVEL 1 % SAND 18 % Source TP-1 Sample No. Elev./Depth 4.0 feet SILT & CLAY 81 % LIQUD LIMIT %, PLASTICITY INDEX % Sample of Source Sample No. Elev./Depth GRAVEL % SAND % SILT & CLAY % LIQUID LIMIT % PLASTICITY INDEX %, GRADATION TEST RESULTS Job No 01-185 FIG. 5 KOECHLEIN CONSULTING ENGINEERS 0 1 z 3 u 6 7 8 9 Pressure, p, ksf Sample of SILT, Sandy Natural Dry Unit Weight= 101.0 (pcf) Source TP-1 Sample No. Elev./Depth 3.0 feet Natural Moisture Content= 9 % Job No. SWELL -CONSOLIDATION TEST RESULTS 01-185 FIG. 6 KOECHLEIN CONSULTING ENGINEERS, INC. Consulting Geotechnical Engineers CLAYEY BACKFILL 10 1 � _—_— — MANUFACTURED III.II — WALL DRAIN I I� i iI COMPACTED BACKFILL BELOW GRADE WALL EDGE OF EXCAVATION (EXCAVATE AS PER OSHA REGULATIONS) FILTER FABRIC GRAVEL- 12" --PLASTIC SHEETING PERFORATED --f— PERFORATED PIPE 12" MIN. NOTES: 1. DRAIN SHOULD BE AT LEAST 12 INCHES BELOW TOP OF FOOTING AT THE HIGHEST POINT AND SLOPE DOWNWARD TO A POSITIVE GRAVITY OUTLET OR TO A SUMP WHERE WATER CAN BE REMOVED BY PUMPING. 2. THE DRAIN SHOULD BE LAID ON A SLOPE RANGING BETWEEN 1 /8 INCH AND 1 /4 INCH DROP PER FOOT OF DRAIN. 3. GRAVEL SPECIFICATIONS: WASHED 1 1 /2 INCH TO NO. 4 GRAVEL WITH LESS THAN 3% PASSING THE NO. 200 SIEVE. TYPICAL WALL DRAIN DETAIL tj JOB NO. 01-185 �i FIG. 7 KOECHLEIN CONSULTING ENGINEERS, INC. Consulting Geotechnical Engineers CLAYEY BACKFILL 10 COMPACTED BACKFILL EDGE OF EXCAVATION (EXCAVATE AS PER OSHA REGULATIONS) FILTER FABRIC PERFORATED PIPE NOTES: MANUFACTURED WALL DRAIN -RETAINING WALL 1. DRAIN SHOULD BE SLOPED DOWNWARD TO A POSITIVE GRAVITY OUTLET OR TO A SUMP WHERE WATER CAN BE REMOVED BY PUMPING. 2. THE DRAIN SHOULD BE LAID ON A SLOPE RANGING BETWEEN 1 /8 INCH AND 1 /4 INCH DROP PER FOOT OF DRAIN. 3. GRAVEL SPECIFICATIONS: WASHED 1 1 /2 INCH TO NO. 4 GRAVEL WITH LESS THAN 3% PASSING THE NO. 200 SIEVE. TYPICAL RETAINING WALL DRAIN DETAIL JOB NO. 01-185 FIG. 8 2194-02 Tax #2105-194-04-001 JOB NAMIE- Lot #10.2, New York Mt. Project BENBOW 2102 West Lake Creek Rd., Edwards JOB NO. f) P_ / qo)-� Printed In USA m. TION 1 idr ffffl0�0' STARTED DATE COMPLETED DATE BILLED n. MEMO- W.0119. M I EN6,6INAI ill INFM�=ff.44MM, W%MWE 0�� "WHE 17121 MIKE �El� JOB COST SUMMARY �mvw&fflml I'M 4-AL SELLING PRICE E �111 TOTAL MATERIAL mE _152W m INSURANCE [it �11-4 11 IN 0 COSTS I arm rol 11 "i.FMISC. Fg, Vol 111 N WE I �NmllfffrlmlI. F 1 W4111 I'll mmm 9116M "Id "4lKMWAM=%X-... ------ -T-4 M I ME AM' I 1 Alill 1 Do .1 Al TOTAL JOB COST! 71 Ow OSS PROFIT; 11 W�El Ni LESS OVERHEAD COSTS % OF SELLING PRICE Ij _■ NET PROFIT, JOB FOLDER Product 278 441� uk'. x 47 4L I- L JOB FOLDER 6 is _W dr Q14111 1) J�y &6 D 'nA-v-k -,a, 4S 0 CO ckA 911 c Lc/vis OLO "A- cl/?/� 9— (0/-//0,!) Ok jo A0V V- -1 , I -L - A Z IAV �07 ""goo X2f I- _ - - -- = - -' --. - - :. - - - - , _ - - -- -- - - -- - - - - _ h _ - _ -._I _. _ - _ _ _ _ _ _ _ _ - _ _ _ _ __ _ - - - _ - _ - _ - - - -.[ ,-_- _-- - r-_-- - ._. - - - _ _ - - .- - -- -- - . - _ _ __ - -- _-_ - __ _ __ _ - - -- _- _ -_ . _ - - _ -. _ - - - : _ - -_ _ _ - _ - - - -- _ - _ - _ - _ - - - - - I - - - _ - _ . _ _ ___ _ _ _ _ - _ _ __ - _ - __ - _-- _ - - - - -_ - _ - _ _ - - _ - - _ _ _- _ , _ _ _ - - . _ _ _ _ _ I± - - - --_.. -- - - -- _.-- - ._ _. - _ _ _ - - - _ - - - _ - . - - _ - - _ - - - - - .. - - - - _ - _ _ _ _ _ _ - _ _ - - - _ _ - - - - - - _ - - - - - - - - - - - - - - _ - - - - `- _-- - - - - - - - - - - _ - - _ i - - .. - _.. - -- _ _ - „- _ _ - - - - - _ _ - - - _ _ - - - - - - - - - - _ - - - _ - - - - - . - _ - - , -- - - _ - - - - - - _ - - , - - - - - - - - - - - - _ - - - - - - - d-t - - _ - - - = _ _ _ .-r �. " f ,. T� _ _ _ - ,- ' , - i _ z o .r _ rowmate Location _ M S } v , a See Note - # Out of Ex1lstin Tank •, =i ` M, I - _ of Water Pum s erif existin Invert g _ 1 _ ` , , - i ,l _ - - - k 1 -_ _ � _ � .. , _, � _ � :. h �_ � Vie t Labe free � '�N - � ,i rovided :♦ .. : _ , - - - -- _ � _ - _ _ 1 � minimum slo a can- be , '_, ,, � \-� �_ � - - '\ ,{ ,: x i _ P _ - ,. and Verif P � _ s _ _ � -_ �-� Assumed Inv. Out 19.8 - , ♦` _ ' �. ; : ,_ -. \ \_ �. , _ " o - - - �� to the new field. _ = X_ _ from the tank = 4- - l- .' - _,.` X -";� • s'/ - - -.fix,.-; \ -_� _ iltrator Trenches -, �_ existin i e at outlet of existing tank. - Pro osed 3 Inf P Connect to 9 P P - _ - - - p f - j _ _ �i f - Lon I = 100 100 tr ► -, \`.� , --.,- , _ III III w N `� ell `� �� Notes. �' Surve Genera 16 16 Units I y 17, f ) _- Verb `exfs �n size 1 20' uTluT,r\�5= ;. i W ZOM I MENT l - - ' - EASE z �< - - - ed tJctober 8, 2001 and ovide 1.5 M.ax°Cover. �wi� ;. ;_ ': _ m i - 1) Survey Date comment Pr \ '`_-����_ , Septic Tank �- 3 - '` 1 NOCNi _ - - completed October 10, 2001._ _ . - - Ai�NE I _ - - __ _ - _ _ - - _ - s - ---�. 1. - Qllon _ re aired - - - I _ ;h:. __�-• -... ,�_.`. _ ( C� - oi'•'o _ i r - ments Lot lines. Building Envelope _ - _ - - _ _ _ -- - _ y2��� g - - Q _ - _ _ - - _ - - - - _ - - _ _ - 2) Location of, Improve , - _ and Easements are based upon the Final Pla ` - �- - . r Mountain Pro' ct. as . I W . �I k . Resubdiwsion of Lot 10. New 1e i [ - filed for record August 27. 1985 at Book; 423. Page - - _ ' - ffice of the Clerk` _ ' I _ j - 578, Reception No. 319844 in the 0 - � - I I - - / ' of Ea le State of Colorado and % '� f % and Recorder. County 9 ,,� nd at the time of this survey as - - - - - Survey Monuments fou AD / r � _ _ shown hereon. This Survey does not constitute a ._ - , boundar survey nor any investigation into record _ - , . I ' / / / �� I y ` . easements or encumbrances associated with this 1 I - - - 3) ASSUMED ELEVATION DATUM: 8217.E for the top o - ,�� / / - I - : s I l monument "Station Tarp";being an 8" ,W e - - q' / ` - - _ 3 the survey �" a / / �2J�• �S; w I \' I - and 1 'n southwesterly of the south horseshoe�it. as ` I - . - _ yi g a LOWER POND / "� -� _yr` - , '� E / - -� _ � � 1 I ,,\ti _ __ 1 1 shown hereon. This elevation data is inte-Xp ated from ��__ / - - - / W� 27 / _ _ I i ma rovided b No Na rchitects. o / �� 6 �� _ . topograph c P p Y / / S _ / _ _ `_.I . . - - 4 CONTOUR INTERVAL• 2 foot. _ . ; _ ) / / / �FjO �0 / / sXuK,, y/v�� I 25, \r 5 Utilities are shown approxim y and should be field - Assumed/0pproX locotto �/ / W� / / _ - i. ! verified poor to excovot�op I I I - . �! - 6 Me r Land S terns darts not warrantor certify to / _ Of a I$iing field; / poi _� i . PT,,' I I I ) _ _ - - the inte rity of an digital Data supplied in con function \.� / f E CSC / / / / �// _ . 9 surve . ' FIRE Exist / ! ��.cP / / / i I l . . with this map ar y . ! �? RING rseshoe i a �N - � / / -.1 / i = I , I _ 7 STREET ADDRESS: Not Posted - • ! ?� � ? H° it 1 ,/ / /l / j i _ l ` hown . ° P / ��� . / / c � / / _ J \ I 1 f I _ 8) Location an dimensions of Building Envelopes �Q - / / ! ,. W , _ , / i r i / c / / / ) • hereon was scaled from the Final Plat. P / Bxist. / N og'03 5� T/ // / / / JJ �Q? Hors it �� 195.00// / I k � - // o // t Qo,�r _ I I I E - - / / '%\J 4r .� / a' Existing I I" - - . . ' r - _ �- 1 Q° �� / 5 I .--� �,. f a 3 BR House ' W I 0 I - / _ - ,� ask �, - -- LOT 0.2 o I I - - // / - ` , I I I / -t Io I r _ -_ ♦.. _._. ! �� ' 866 acres c 44 t / .• / ,._._ _ ,� Pro os _ , , :.r v, 15. r �i _ - �. l _ o o scn v .��i�,"_ Existm Sewer �. V �� / - / / /� ,2 / s �_ - -: _ ea _out 9 ao �.. I - II _ ab i / / / / -+ -y-• - I / i _ BR = 1 / s / 1 wer - _ - $Q i : > - osed Se - _ / Pro I tU - s �k� / , / 1 Ad�iitio p __ - /h=•- - - I . -'�� 1 f '� / / 1 - t - _ ;k r /- _ _ - i I- r - - /_ i q / / '/ _ __ - _ _ - -f' _ - = --_ - -f - _ _ _ I _ - - - - _ - ._ 08' i _ i - -_ - / / - / _ ' - 1 - - / 4 - i_ / / _ / I / / _ - - - - - - - - - - a - - Z - - - -> I - - - - - - s / .- -_ 1 8 / � ' \_ 1 `� _ _ , 1 - - - - - ? t _'- - - s iA - - - - - i 7 s _ - i w. ' a I ? _ _t o- 4 - I - +48 ti A - ro _ i - - - _ - 1 _ - - - - - a a - - - - - - . - 'P 2 / - �:: I 25 . O F / - -� ' V I ' - -- a a - I g / a- �' t^ s a f ' '� / / _ I 1 2 _ / > a - . .- ----._:---- i`- - -Q `� - ?% - - 1,,,�- T - -` _ / �x, - �._\'_. �'. ?` ?-ems--'\ / / - aaa -aa �•-- �, 1. • - - - I-- - ---.- : - -- _ - - to - - 1 _ q - a /': y.•-. _ - - - �.� a . - _- - C� ! \ / ; = a / =} is :ems � o 'A I A ' / I - . , , � \ ',, - - _ / ___� / / f_' .� -- / �/ ✓aaa a✓✓ ✓a _� a 8 D14. S WTE _ / ., a 5 / ti __ 2 4 Ir --,,",,�' .. _ --.8 a _ ANTE NA �j 1 �is� . _ �i %GHQ/� \ ♦ :./*��^, " .�=\ . (y ✓ ' / a •r / "{ - I .t , _� \• le r a i f �• o x - `' - \ \ •r - \ k �' f•., 3 �\ � O _ j;- 1f ,'.. i t - _I / - - s vC52 _ /I _ - - o � ? i ✓ a C '"�`- .W` X \ ; _ -..ems- - -.I -� _ - _ '> - ti ti } f :, _ M a v x O 1 _ - Y - r. - i �► _ \ _ ' - ti .1.._ ♦ - ,_ r , _ ,-. _ Dry - _ x i >, - - - - �� " _ r r , , .._ , .,_ i _ r r_ _ > / ti �_ z f ? J _ r �; - _ l _ --, l . _ .� _ _ . - t _ _ _ 3 Y - , f. _ , _ _ _ ��- _ - n� - is - - - N -. -% -. rt �/� to __ _ � -' - - _ ,_ 1 - . s`i y • -YJ I _ T_ -• F. s - _ _ _ ✓ 3 r. >> _ - - `- _. -`. l - - ./ram__ _ - _ _- - - _ - , - li_ _ - _ r . _ ! t- / ter, > _J-= » - - - - 24 �.71.� / r: _ t > . g _ . 1� Grav .. t _ _ _ _ . t tp - _ - r �; ! _. _ _ - _ , _ _ _ _ _ _ _ _. t -. _ . -: ` \ 822E - - / / / _ - - _ _ - � - / - +� s" - - X jti 1' j? \.I -_;''\ '1s s/ �,. a ✓ I a �' r - a p° �. r a a � - a �' 1 _ _ - ,-_ 0 - � i'a_` _ j- - _ _ _ _ N I. _ - \ - 2'Z•$/ 'I '/ - /�_ // // a ��____�__ a a_aa ��..� - - I� q a - //�. a _-aaa ��a✓----•- a./.V, r�� --. -♦I-~ - \-. �$ / // / / a. aaj aaa___ / -WW` �� �'�' ���' ����---8260- �r `o ,_'. �23 /�' / // // �di 1.� / s!"�V _ / /- i ��� as _ JZ: Ins ection Par 1���../( ,a2 ��f,��.�s _ _ - - - - p +. / / - aaW -`a\ ` .���� _� / tea_ uTM___a --. ;�''i . � `!I -r'a. :. f� �-:'I € i 1 r 3 / �► a a a - a �.- \ ���i a a �. / a f` cr / I =' Ibl .� a ` '' t r d • Q ~'+i _.+aaa 23--- / / ✓✓ _a aaa -/ �- -�v ✓ / a �J .� =�.^� , L.F �.� - --- - - - - _ _ � _ _ `I _a a 81 -/ I _1 _i _aa \ _ / a_ 4 a ', / � ��- as / Cr I -,_ ;_�\ _ Tom_ #Y` '�- - - - - - 1----`•++> -• - ! _ _ _ _ -- _ - - t - `- I -a iaa2� :1�r // // aaaa _aa--_-� a•.. \ � a / `� / a i��a_- aaaa aaa ' /`- \, x'.4 r "t"t _ I__ {y��W f as % / / - - a ate' / a� /�.- -a a a/ �. /_ \ `✓ r f�= - t- >> I Pro osed 2 to 4 higher - "'"� _ _ _ - `_ P / q� 7 / aaa �.. a� a / _ - }.b �.aa aa_ as �I'� 4 \• �: �'�' - 1 tea_ I Z �� _ _ - _ - >.r�"_r r24 /// /// `` a�r� �_ ~i/�/�� - My��� ��.-;A.Ta a /-_�✓ ✓ a �,�_ >-._�.�_: - -, ``fit _ -�.=-• - I - Boulder or Keystone Wall �a ,�. _ - -- - ` I� o 0 `✓/ / i �••� as _✓ _ _�i1'� .�� - a� __-..._ �.a 'r- �� q�, / / __-✓_ / // ----'_ �I -__ate-_ as _�� O a-;s - r•,...:�i _ _-.i w V I i. Remove Trees BCD _a2''� �/ ��' ------ / -- __- - R, - (v Q _ _ a _ - ` a - a ��_ -_ �. =tea'' t - - I w _ - 44.E / I / r+ _ - �• a _ �- _ a� _ ► - a' = < - - - i Possibl remove Tree Q f. _ _-- ___--- �� - ..:� - - - - - Y - �'�Q/ � I a__ a ��,-�.�.�= sa a- a_a ✓_`- `./' ,r `-- -i _ - �: I AI a4, ,, �' - _ i _,. - - - as I as 'C - - , \, _a 1- I �._ - -• _ _ - _ - - =y Z,j r_- I `_ //. _. � _•► --- -/ - aaa _�.s.--,` - -' \_ xr, _ _ '� - - - �i - - - a {' s € I-- --_- _ _ -` _ -- / // t� _J a -I // --_r.a__ _a I aa�i�a 3 -�: _ _ 0•... c - -� a J �� - - rir - - - a n 2 -, / . - - - ✓ - - - a - a r=/ -�! - ^1 �N� 5 �- __ ), _ - - ': -I _ _ I �„- - - - - - I _ - _ - +I -- �t3`5 / _ / a / . - - aaa _ - - � - _ a _ J a - _ �1 . 4 . � �, . > "N� �. a _ `►D _'.R - -'_ _ /. D - a a _ i - - _ - _ _ - - - / / / r _ / "'�__ _ aaa - _ a _ a �_ _ ,'� >( K _ ,, ' • -,'� /` - OR� V G-.-'= � � . _ - _ a - - I - - -, - i �aZ�4 // '/ -f ��_�✓a as-- - i �.-- JVpTE ME�y o S - - - 6 I I - _ _ - - - - - a a - = �, `. "G - � -'.r r_ �' - Y j -Tk\.1�� 'EAS - � - I N j = - - - _ _ - - _ _:_'+s - _ - __ _ - - _ _ r825 � / _ - _- � _ _ - _ - - _ a a a :, a'- - .� �. - - r- _ ' �;�' �.,�, -, - - - ti I=� _ - - _ - • - - y_ i _ - - - - - i-_ . - Q��- / / /� �� /-ter -�,��a -�/ , -a. _ -�^ v % - a - - '.f _ _ ; `_,\x=A �aI - �� - _ - _ _ _ _ 5cZ T _ - _ - - _ - _ _ -- t - _ - _ - ,�i a / � i I .� �`. _ - -i a - _ _ � - -'.ice - x <}f .Y r� _ a - I - - - - - _ - _ - _ - - _ I - _ _ i 'g a � �i _ / a __- _ >. % r -ate_ _h -i ^'` �.. `-�� r 1 ,"_ja a _ l I =2 f x; /� i - _ -'- : ;'� _ - _ - - - / �a as / I /a �-- - .�- - ft -' - - - - - - . - - ` -- --- - - - - _ _. _ _ �� I 20 aaa ,�_.----, � _ -, max = , -, �. _ = - ,_S _ a _ � - _ GRAPHIC SCALE -\x �; 6 I Legend Proposed - -- - Setback - Well e .,..- Setback - Stream . -81 1 6�r-(yamM- Contour w Walls ^ Cleanout (or Inspection Portal over field) - f�' �Z // tea- -�- -'�'Ca�Q C�\, �' � '� =,�%� ' -�f� , ia/ i-� 10 20 - _ _ - - - - - - - - , - - - / - - a/ - I I.' ` _1 '� �` � .�X18t >" < \ •Js- ti ? '-„�` . , _,_, � ''4_ -= i /-"` - - - a a _ 20 - 0 - . . -g26 �. is ° - I `, _X .- z> ` �= r i Ro°� - _ - - -- - � _ _ j / 1�r / / !. K X. \_� , � ?':X _-jam;_ -`' \, � - r ' > i (IN FEET) . _ - . _ _ �/ / \ram "," \ ,_/ -__ � _ _-� - inch = 20 ft . 1 - - I - - - i I - p - F I - _ - - -- --- - _ - }-- - - _ I I A: - ' I- - r 1 --. { - Q ./� _ _ _ _ - r' V , _ - - _ - . " - - - _ -- -------------- - -_ .�� 1 - - -- =- - - = - -- tJ� . - ad later - - Note =_ t, - I _ 1 1f-the-existin"ovet leach-field-is-encountered/excavated during -the construction of the- General Notes General Notes Continued new field. -_the gravel wll likely need to hauled to- the dump. and -replaced withF sand. It _is , _ - w enches as hi h as oo ble (minimum 1 bury_ on - _ t AI ine En ineerin ,Inc. at least 48-hours prior to installing any septic system 15. The Owner must realize an on -site sewage disposal system is considerably different from -__ _ therefore proposed #a raise the ne tr 9 - _ P- -- 1. Contac P 9 9 - _ downhill side , of _trench) and place l'- fll over top. If grave($ encountered during construction. improvement. public sewer services. The Owner must be aware of and assume the responsibility for distal before rocedin with _construction.= - - - - - � -� continued maintenance of the system. We recommend the pumping of the septic at the end . �c L_1Et immea Y_ P 9 _ - _ n 2. Compact sewer trenches to 90� standard proctor density, or per soil engineer's of the first year of use to monitor sludge accumulation and a minimum of every two years recommendations. _ - afterwards. There are also daily considerations; such as not putting plastic or other - non -biodegradable material down the sewage disposal system. Also. water use must be SEPTIC TANK SIZE - 3. Provide risers on septic tanks to finish grade. carefully monitored so toilets are not allowed to run when seals malfunction.- To illustrate the r oms Verif tie size of the existing tank and provide point: it should be noted that a running tolet would consume in excess of 1000 gallons per Minimum tank size - 1,250 gallons for 4 bed o Y 4. Comply with all Eagle County and Colorado Department of Health regulations regarding day, if allowed to run. Excessive loading (such as from running toilets) will flood and 1,250 gallons. septic system installation. irrevocably harm the system and stress the on -site well ' - - y t �" - 16. We also caution u a ainst installation of a water softener The high levels of salt from t t'%r,.- SETBACKS 5 Provide inspection portals per Eagle County regulations. Y° g I_ - - ".>\ i t ' �� � � the back wash of a water softener is detrimental to all on -site sewage disposal systems and ». of water is a wel located near the "wishing well" on the n sewer lines and se tic tank. a separate drywell should be constructed for backwash waste if a water softener is installed. m i- _ 2 TO 3 DIA -, I �; ��, Well: It is our understand that the source 4 •... r _ - _ - - -_ y f _ - _ - - _ _ - f /�' o tion el ch. Provide minimum setbacks per table 6. Provide minimum 5 horizontal distance between trees a d p No landscaping or plastic can be installed over the disposal field that will reduce the - - o t - - i30ULDERS �f '. east side of the ponds at least 120' from the abs rp en _ -- _ - - "i �� below: 7- Field -all n sewer to avoid existing trees. buildings and structures evapotranspira - I - _ _ _ o g tion from "the field . 2 - _ - - 10' se aration between water and sewer lines. Or encase per Colorado Q = I s tern inimum slo a from buildin to septic tank. 1� 17. Provide minimum p 1 3/4" WASHED . minimum horizontal distances in feet between components of a sewage disposa ys 8, Provide 4 minimum cover and 2� m P g De artment of Health re ulations. N - ROCK Table of -, •. . - �� installed after November 15. 1973. and pertinent physical features. minimum slope after septic tank with cover as required to provide 1' to 1.5' cover over P 9 I _ . u? a r . o - of j _ 1- - =_L o "* - a N .- o I I MIRAFl 140N o _ \_ _ . i ff _ -- 1 - o _ OR EQUIV. m o �1 - - - - , .\ \\, ", I ! rn ice-- y \ \ .\ =, i ;/ :\- - __ - - - .\ \ / \i t ' l , w ♦ \\ \ -3 s. a \ \\ F I 'a 0 o I r o v �?, - ,�: \` / < \ o! \, r f RFORATED _ o ` fA -- - a / /ter ", - ,.; 4' PE _ �,- j I - J I _ - a� - , '"'�•"} �� 9` -/ 1 PVC ' 3= c - \ `�'. ;_ - - �< - i co - 0 0 "; - / s ;_, - ' I X Y. y . _ { m z F o o f' ,</� %'�, /r < ='ii," i ! %mod - ✓ I - > M 0 � _ - ` - DAYLIGHT �� �- f�/- - w o AIN - a TO DR Q i s Y �- 0 _ ( a - REQ D � INFIL TRATOR -COVER L h omers as k nd abso r tion trenc c I rotors. a tic fan a infi t r eanouts s i to sewe cl location t es P 18. Provide to P n at 100' s acin but not between dosing tank and tee). required by Eagle County for as-builts, and submit to AEI. 9. Provide cleanouts at bends, a d P 9 ( - 10. Sewerline to be schedule 40 PYC under roads, SDR35 elsewhere. - 19. 4" SDR 35 PVC ® 2% min. slope, 4' bury before septic tank. 1.59E after tank. ' minimum between trench walls. - 20. All septic tanks" to be concrete. - 11. Provide 6 11 oth locat ions are ' fil r tion a er b w II or an in t a rce is a e h water sou ( n know if t o 9 Y 1 nn 21. We do t 12. Do not begin any sewer .construction prior- to notification of Alpine Engineering, Inc.. G e _ Palmer 970-926-3373. The septic system is also to be inspected by Eagle County Health approximate). Department and Alpine Engineering, Inc. prior to backfill. contact them for this purpose as - - - - _ well. . installation of the subsurface 14. We recommend -that -the Absorption Field be seeded after disposal system. A good native grass cover will promote evapotranspiration from the field. We recommend using a seed mix such as Foothills, Pasture or Prairie mix available at local feed - and seed stores. These mixes do not require irrigation and develop a growth 10 to 15 inches - high. No automatic sprinkler system should be installed above the disposal field. • - - BOULDER RETAINING WAL . . o _ . ` O I ' _ Scaler 1 - 2 -0 - I - o ` Scale: 1 - 2 -0 - - =- I - _ - . _ _ _ _ - _ __ - _ __ - - - - - - - - - _ - - - - _ - - - - - - - - - - _ - - - i - -- I_ - - - _ _ - - _ _ _ a . - . - - - r _ - -_ -__:. - - - - _ - _ - - - __ - - - - - _ - - - _ - - - - - _ --_--- _ _ -_-__ - -- _ _. - - - - - - - - - - --_ - - _-_ - __-- _- . Spring, Wells, Suction Lines Potable Water Supply Line Dwelling. Occupied Building Property Lines _ Subsol Drains Lake. Water Course, Irrigation Ditch or Stream Dry Gulches Septic Tank s#s #ss ss# Abso tion Trench 100 25 20 10 i 10 50 25 10 . sss - :s s i - Septic Tanks 50 10 5 10 : 10 50 10 s, s# ss ss Building Sewer 50 10 10 50 10 Apo peon S �., P _ 22753 = o _ .� _. •1 0..1 3 aD 1 N EM it N O O N r 0 N X X X X x x x x v � 0 w w O Z U � U W �p Q W X 2 U 0