    HomeMy WebLinkAbout646 Aspen Bluff Ln - 194121404002INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT 
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION 
P.O. Box 179 - 500 Broadway • Eagle, CO 81631 
Telephone: (970) 328-8755 
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2189-02 BP NO. 14123 
OWNER: JIM GREGG AND COMPANY PHONE: 303-472-8002 
MAILING ADDRESS: 30082 TROUTDALE RD. EVERGREEN, CO 80439 
APPLICANT: JAMIE PAPPAS PHONE: 970-845-2528 
SYSTEM LOCATION: 646 ASPEN BLUFF LANE, RED SKY RANCH, WOLCOTT, CO TAX PARCEL NO. 1941-214-04-001 
LICENSED INSTALLER: VAIL RESORTS DEVELOPMENT, JAMIE PAPPAS LICENSE NO.45-02 PHONE: 970-845-2528 
DESIGN ENGINEER: FLUIDYNE ENGINEERING, THOMAS KALLENBACH PHONE NO. 406-586-2289 
INSTALLATION GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 6 BEDROOM RESIDENCE 
1500 GALLON CONCRETE SEPTIC TANK, 1000 GALLON DOSING TANK, AND A D-NITE UNIT, FOR THE CONNECTION 
TO THE CLUSTER SYSTEM'S MAIN LEACH FIELD AT LOWER ASPEN BLUFFS, PERMITTED IN ISDS PERMIT #2112-01 
SPECIAL INSTRUCTIONS: INSTALL THE TANKS AS PER ENGINEER'S DESIGN DATED 2/27/02. THE METRO DISTRICT 
GENERAL MANAGER NEEDS TO CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER 
FOR THE FINAL INSPECTION_ PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION, OR WITH ANY 
QUESTIONS. THE FINAL APPROVAL OF THIS PERMIT REQUIRES THAT THE MAIN SYSTEM PERMITTED UNDER 
IS-2112-01 BE COMPLETED AND APPROVED AS WELL. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT 
BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. 
ENVIRONMENTAL HEALTH APPROVAL: RAYMOND P. MERRY DATE: MAY 6, 2002 
CONDITIONS: 
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM 
REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING 
REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING 
DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL 
ACTION AND REVOCATION OF THE PERMIT. 
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL 
SYSTEM TO BE LICENSED. 
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): 
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE 
DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF 
THE SYSTEM. ' 
INSTALLED 1500GALLON CONCRETE SEPTIC, 1000 GALLON DOSING TANK, AND A D-NITE UNIT EXACTLY AS 
DEPICTED ON THE ENGINEER'S DESIGN. 
COMMENTS: THE ENGINEER'S FINAL CERTIFICATION WAS RECEIVED ON JUNE 6, 2003. THIS OFFICE WAS WAITING 
TO RECEIVE AN AS -BUILT DRAWING OF THE SYSTEM COMPONENTS FROM THE CONTRACTOR. WE RECEIVED A 
LETTER ON OCTOBER 20, 2003 STATING THAT THE SYSTEM HAD BEEN STAKED OUT ACCORDING TO THE 
ENGINEER'S COORDINATES, AND THAT IT HAD BEEN INSTALLED EXACTLY AT THOSE COORDINATES. THIS SYSTEM 
IS CONNECTED TO THE MAIN DRAIN FIELD THAT SERVICES THE LOWER ASPEN BLUFFS AREA. 
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS 
MADE. ARRANGE A RE -INSPECTION ORK I E . 
ENVIRONMENTAL HEALTH APPROVA Y-1..1.. 2004 
Incomplete' Applications Will NOT Be iccepted 
l (Site Flan MUST be attached) 
1 can _ $SD6 Permit � 
emu 
— oZ I I �' 6 wilding Permit �•` —1 l-,Z5 
APP ICATION POR 'IHDIVIDUAL BMWE DISPOMM ByBTEM PBRMIT 
ENVIRONMENTAL HEALTH OFFICE,- EAGLE COUNTY 
P. 0. BOX 1.79 
EAGLE, CO 81631 
328-8735/92713823 (Basalt) 
* PERMIT APPLICATION FEE $1s0.00 PERCOLATIGN TEST FEE $200.00 
KAKE ALL REM=TTANCE PAYABL$' P : REA= CO,VNTY TPY. AsUMMq 
PROPERTY OWNER: qe4, C C ov (vC"-►�.-- 
MAILINGADDRESS: 2CO 8 a.. trc>uf&c.,) e- ( �c,�P/� 2� , Cy 8aj3� PHONE: 
3o3 
APPLICANT./CONTACT—PERSON: PHONE:'ara.& 
LICENSED SYSTEMS CONTRACTORV'Atr Le's PHONE: 
COMPANY/DBA: \)O ►A �es�• ADbRESs: . ()O Qox 'i S� (}�ua✓�' C� � tao 
PERMIT APPLICATION IS FOR: (>I NEW INSTALLATION ( ) ALTEA&TXON { ) REpA3:A 
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: 
Legal Description.: 6 S duff_ .�.�tie 1-incl F14 
Tax Parcel ' Number: Lot Size:. l• �d 6 Q,c 
Physical Address: _Lot c� G �� A -sac Uoff 2--e.; 
BUILDING TYPE:- (Check applicable c�tegary) ' 
(�q Residential/Single Family Number of .Bedrooms _6 
( ) Res idential/Multi-Family* Number of Bedrooms 
( ) Commercial/Industrial* Type 
TYPE OF WATER SUPPLY: (Check applicable category) 
Spring ( ) $urfa e 
(X) Public Name of Supplier: �Alc 
*These systems require design by a Registered Professional -.Engineer 
SIGNATURE: Date: 
AMOUNT PAID: RECEIPT #; � DATE:�- 
CHECK it: — CASHIER: 
C 4U4 
DEPARTMENT OF 
ENVIRONMENTAL HEALTH 
(970)328-8755 
FAX: (970) 328=8788 
TOLL FREE:800-225-6136 
www.eaglecounty.us 
May 11, 2004 
646 Aspen Bluff Lane, LLC 
511 Lionshead Mall 
Vail, CO 81657 
EAGLE COUNTY 
RAYMOND P. MERRY, REHS 
Director 
RE: Final of ISDS Permit #2189-02, Tax Parcel #1941-214-04-001. Property location: 
646 Aspen Bluff Ln., Wolcott, CO., 646 Aspen Bluff Ln., LLC property. 
Dear Property Owner; 
This letter is to inform you that the above referenced ISDS Permit has been inspected and 
finalized. Enclosed is a copy to retain for your records. This permit does not indicate 
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding 
the care of your septic system. 
Be aware that later changes to your building may require appropriate alterations of your septic 
system. 
If you have any questions regarding this permit, please contact the Eagle County Environmental 
Health Division at (970) 328-8755. 
Sincerely, 
Janet Kohl 
Eagle County Environmental Health Department 
ENCL: Educational Brochure 
Final ISDS Permit 
cc: files, May 2004 Chrono file 
500 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 
DEPARTMENT OF 
ENVIRONMENTAL HEALTH 
(970) 328-8755 
FAX (970) 328-8788 
TDD: (970) 328-8797 
TOLL FREE: 800-225-8136 
www.eagle-county.com 
EAGLE COUNTY, COLORADO 
Date: May 6, 2002 
TO: Vail Resorts Development 
Raymond P. Merry, REHS 
Director 
FROM: Environmental Health Division 
RE: Issuance of Individual Sewage Disposal System Permit No.2189-02. Tax Parcel 
# 1941-214-04-001. Property Location: 646 Aspen Bluffs Rd., Wolcott, CO., 
Greeg & Company property. 
Enclosed is your ISDS Permit No. 2189-02 and a field copy of the engineer design stipulated on 
the permit. It is valid for 120 days, or for the duration of your current building permit for this 
property. The enclosed copy of the permit must be posted at the installation site. Any changes 
in plans or specifications invalidates the permit unless otherwise approved. Please note any 
special requirements that may have been added to the design by this department. 
Systems designed by a Registered Professional Engineer must be certified by the Engineer 
indicating that the system was installed as specified. Eagle County Environmental Health 
must also view the installation prior to back filling. Please call well in advance for your 
final inspection. Your TCO will not be issued until our office receives this certification 
from the engineer, and views the installation. 
Permit specifications are minimum requirements only, and should be brought to the property 
owner's attention. 
This permit does not indicate conformance with other Eagle County requirements. Please 
notify this office if you have not been contracted to perform this installation. 
If you have any questions, please feel free to contact the Environmental Health Division at 328- 
8755. 
cc: files 
Fluidyne Engineering, Thomas Kallenbach 
OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 
F L U 1 D Y N E 
Scientists Engineers - Inventors 
June 6, 2003 
Eagle County Environmental Health Department 
Ray Merry, Director 
500 Broadway 
P.O. Box 179 
Eagle, CO 81631 
Subject: Red Sky Ranch Lot 9 Certification of Completion 
Dear Ray: 
Please accept this letter as confirmation of completion of the components serving the 
Red Sky Ranch lot 9. The individual system doses a pressure sewer for the Lower 
Aspen Bluff system. The lot 9 components are comprised of the 2000-gallon septic 
tank, 1000-gallon dose tank, and the Eliminite ® unit. 
Fluidyne, Inc. inspected the system during the last visit to the property (May 19, 2003). 
At that time the system was complete. Vail Resorts Development Co engineer Jamie 
Pappas, P.E, has tested the system. The certification process involved a leak test on 
the septic and dose tanks and a test to assure the transport of wastewater through the 
forcemain to the Lower Aspen Bluff Cluster (see enclosed). 
The inspection reveals the functionality of the system and its ability to support the 
treatment of wastewater. This letter serves as a certification of the system, that it is 
operative to provide wastewater treatment and that it was built in accordance with the 
plans. 
Please call with any questions. 
Respectfully, 
Adie hillips or Thomas J Kallenbach, P. E. 
Cc: Jamie Pappas 
uu/,.uo/ 4UUJ PAI 
1L; it MA 
M DOD LM 11111Qy11e 444 KAI JJEK I 
. . T0.0M.... ,� cos's 
'OR mri — 
9s:-ti. ftS:L:,900Zi20i00 
VAIL R E.5o R T S D EVELOPMENT COMPANY 
Sung 5,7003 
Ju5ftBuchanat 
Fluidyae 
25 N. Willson Ave. Suite F 
Bozeman, lVlT 59715 
Fax; 406-596-2335 
Dew Justin: 
. U you are mare we have completed the necessary testing requir=ents for the residence 
at Lot 9,Aspen Bluff, Red Sky Ranch . I have completed the testing requirements as 
iwt=ted by Fluidaye Inc. The water=nigh# ess test and verification, of correct opeMiiOn 
of the farce main p=p is discussed below. 
1000 and 2000 Gallorl Tgmk: 
A, water tightness test was conducted ever a 3 day period from August d A,uglxst 9, 
2003. 'There was no measurable drop in water level. Thus indicatiug no measureable 
leak in the Septic/Dose Tank. 
On may 5°' 2003 the force main dosing p urlp was turned on and it was verified that this 
pump operated as desireed. 
Please feol free to call me during the day if can provide you with any iuxthm 
information. 
Thank you, 
Vail Resorts Development Company 
11tA-7 
Jamie Pappas, Project Manager 
PAIL RCIaRTV 
Vail Re-wria Devalopm L Company * 137 Renduvark Road • Pwl Me Box 959 TAYm Colorado $1620-0959 • (970) 845 2535 • fox (970) 8"= * wv w+adc.cornl 
Vail , llwkenrWsa * Kg1%Lane® • $emr Creoke • UdhObr QUO • Armw646* 6 rUd Sky Ruftch* 0 
Z/T ' d 130S ' ow IFMdo13AM Wd9 G : 2 m2 ' S ' wnr 
TI ItJ_C_O3MrR� COT 1 0• IIC70MI TM- Cnr=1 C f'YiI IKITV CF.II I LJCn1 TLJ onl=. -2 
• - - — 1v-11 1 r nr-J e%-W"I1 tu•-� --J t.-JV7-U1 iWOv?G •G Y NUW LUUC-'-Ur--1JL 
October 20, 2003 
Ray Merry 
Eagle Comity Department of Environmental Health 
PO Box 850 
Eagle, CO 81631 
Re: As-Builts For: Lower Aspen Bluffs Lot 99 and Training Facility 
Dear Mr. Merry 
As you requested I am writing this letter to confirm the "As -Built locations" of the mower 
Aspen Bluff clustered system, Lot 9, and the Training facility. Prior to construction 
these systems were staked by Eagle Valley Surveying per coordinates given by Fluidynte 
Engineering Ina, and then installed per the surveyed stakes, Thus, the permitted plan sets 
in your office can be used for "As -Built" information for these systems. 
Please call me during the day at 845-2528 if you would like any further information 
regarding these systems. 
Sincerely 
Vail Resorts Development Company cc: Bill Kennedy 
AiLnueappas 
Project Manager 
AIL 96evkTr 
Vail fteaarte Develop.meat Compuny - 137Benchmark Road ■ P'oyt OlTM $ox 959 ■ Avan, Colorado 81620.0959 • (970) 845.253 _fax (97p) Ei<k5.2555 • www.vrdc.rnm 
Vail - llrmlenridge - KeyataneO + Beaver Creeks' • $etchclvr Gulch(b . Arrowheado • Red Sky Ranch' 
T sT • _S Tnn•ne: --. -- -- -- --- 
2189-02 Tax# 19'11- al,q-0j(- 00 / 
JOB NAME. Lot #9, Red Sky Ranch, GREGG & COMPANY JOB � 
646 Aspen Bluff Lane, Wolcott 
JVd PVWbi r=Um "L7s 
JOB FOLDER meted in u.SA 
is 
A B 
D-NTTE SYSTEM 2' EXTRUDED FOAM INSULATION 
28" DIA_ LID _rrr 
INSULATE BOTTOM OF LID 
__ � .� `�\�\�11_r� ��\�r�,=r�11=r�� j`� . D_ •..• - .• . _ . _ .. =s _* rr��1 �rr,11r ,�,r\r��� r`r�11�� rrr��r= 
4 . • - • d - ad - ° . 
_\\\,rr\ r\�\\_rrr rr\�\\err rr\_�� Q a. Q q. Q• _ d-. a ° a.- - a a d q a 
4 
f\11 
a _ a 
4 0 SCH 40 PVC 
TO SEPTIC TANK 
D-NfTE LW 
PROVIDED BY FLUIDYNE Inc. INSTALLED BY 
CONTRACTOR USA PATENT No. 5534147 & No. 5676828 
D-NITE UNIT COMES COMPLETE AND READY TO INSTALL 
CONTRACTOR TO MAKE CONNECTION TO 4" SEPTIC TANK 1 1/2a SCH 40 PVC 
- FILTER FABRIC 
MIRAFI 140N (OR 
EQUIVALENT) 
1" TO 1 1/2" GRAVEL FILL 
AROUND ENTIRE TANK 2' 
MINIMUM WIDTH 
1 LB BODS / DAY 
RETURN LINE AND 1 1/2" DOSE LINE. ALL OTHER PIPING FROM DOSE TANK. 
SHOWN ON D-NITE UNIT IS PROVIDED BY FLUIDYNE Inc. SLOPE TO DRAIN. 
28" I.D. RISER GREEN FIBERGLASS, INSULATED, CALLON PRECAST CONCFEM DOSE TAW 
WO GALLON PRECAST CONCRETE DUAL COWARTMENT SEPTA TANK LOCKING LID (TYP OF ALL LIDS) 
I FINISHED GRADE INSULATE BOTTOM OF LIDS (TYP) 
Orc� - - - - -- - --- ---- WATER TIGHT 
a JUNCTION BOX o 
1 1/2" PVC UNION 
00 
DRILL 3 16 W WEEP HOLE 
Q r 
Q 
-� 
4"0 SCH 40 PVC RETURN LINE 
SLOPE 1 /4- PER FOOT 
1 1 /2"0 SCH 40 PVC ELBOW 
FROM D-NITE DRAIN INSTALL 
TO D-NITE UNIT SLOPE TO DRAIN 
40 PVC 
----- 
TEE WITH 12" STUB DOWN 
--------------------------------------------- 
-------- 
-- 
4" SCH 
-- 
18" BELOW 
2" THICK EXTRUDED CLOSED CELL, 
SUBGRADE INSULATION (TYP) 
1 1/2"0 SCH 40 PVC 
LIQUID LEVEL 
USE TEE OR 
CONCRETE BAFFLE 
a 
_ 
"HIGH 
WATER ALARM 
OAT 
4"0 SCH 40 PVC FROM 
E U WER ON WITCH 
RESIDENCE SLOPE 1/4" PER PRESSURE JEWER OFF 
FOOT 4' -NI TIM d 
s 4.. 0 F 
N 
lllifri►ii 
1 
\\j\\j 
GRUNDFOS KP 250 SUBMERSIBLE 
EFFLUENT PUMP TO D-NITE UNI 
INSTALL "PIGGY -BACK" FLOATS TO 
RECIRCULATION PUMP FOR LOW WATER 
CUT-OUT HYDROMATIC SHEF SUBMERSIBLE 
EFFLUENT PUMP TO PRESSURE SEWER 
(SEE DOSE PUMP -INDIVIDUAL LOT NOTES) 
I Tr? --,AL r -tl- VC CCW=l / 
PRESSURE SEWER TRENCH DETAIL 
C DETAIL 
C6.4 SCALE: 3/4"=l' 
PIPE BEDDING MUST 
BE FREE OF LARGE 
ROCKS, SHARP ROCKS, 
TREE STUMPS, LOGS, 
& OTHER UNSUITABLE 
DEBRIS. 
MIN 2" PIPE BEDDING 
MATERIAL OVER 
INSULATION 
4" THICK BY W" WIDE 25 psi 
EXTRUDED INSULATION BOARD 
(AASHTO SPEC 
POLYSTYRENE, M230-70) 8' 
LENGTH MINIMUM WHERE PIPE 
IS LESS THAN 6.5' DEPTH 
AND UNDER DRIVEWAYS 
PIPE 
4" CLEAN GRAVEL 
OR SAND 
4" CLEAN GRAVEL 
OR SAND 
4" SCH 40 PVC SLEEVE UNDER DRIVEWAY'S 
UNDISTURBED SOIL 
INDMDUAL LOT NOTE 
SEPTIC TANK: 1500 GALLON PRECAST CONCRETE SEPTIC TANK 
DOSE TANK: 1000 GALLON PRECAST CONCRETE DOSE TANK 
D-NITE UNIT: PROPRIETARY NITROGEN REMOVAL SYSTEM. SUPPLIED BY FLUIDYNE Inc_ 
USA PATENT No- 5534147 AND No. 5676828 
DOSE PUMP: HYDROMAM SHEF 50 EFFLUENT PUMP LOTS, 9,10, 12, 
, 
DOSE PUMP CONTROLS: SJE RHOMBUS SIMPLEX CONTROL PANEL MODEL No. 112, WITH 
AUDIBLE / VISUAL HIGH WATER ALARM 
RECIRCULATION PUMP: GRUNDFOS KP 250 SUBMERSIBLE EFFLUENT PUMP 
RECIRCULATION PUMP CONTROLS: SUPPLIED BY FLUIDYNE Inc. 
DRAINFIELD FLOAT ASSEMBLIES: 3 ANCHOR MINI -FLOATS, OR EQUIVALENT 
1. PVC TO BE JOINED w/ PRIMED SOLVENT/CEMENT WELD JOINTS. PRIMER 
MUST IMPART A SALIENT COLORATION TO THE COMPONENTS BEING CEMENTED. 
FITTINGS PRIMED w/ COLORLESS PRIMER WILL BE REJECTED BY THE ENGINEER 
AND REPLACED AT THE CONTRACTORS EXPENSE. 
2. CONTRACTOR TO PRESSURE TEST SYSTEM IN PRESENCE OF THE ENGINEER. 
3. SUBSTITUTIONS TO THE DESIGN ARE TO BE EVALUATED BY FLUIDYNE 
4. CONTRACTOR TO TEST SEPTIC TANK & DOSE TANK FOR WATERTIGHTNESS. 
ANY MEASURABLE WATER LOSS IN A 24 HR PERIOD WILL BE REJECTED. 
5. SLOPE ALL PIPES TO DRAIN. 
I� 
m= 
20 10 0 20 40 60 80 
SCALE 1'= 20' CONTOUR INTERVAL 2 FEET 
'"WAR 
{ � 5 
�Yr� I I� ACV 
Iz 3T !LLJ _ 
DRAINAGE EASEMENT 
7820 781 7816 7814 7812 - 
\ --- 7810 .7810 
7822 _ 
S 55^24'15' E 416.70', 
7812 
7824 1IfIi f 
\ \ 
----- ----- --- \------- ----- �- 
---------------� 
-------------------- _7826�/ \_ 
782878367834 \ ----- 7814 
40? 7830 
787832 ELECTRIC V,```\ GOLF 
I � 
EASEMENT / ��` I----------------------------------84 
A. 
_ 1,00GALLONPRECAST 
--7816 5 
�� E 
CONCRETE SEPTIC TANK , 
----------------' \ RIMLLEV. 7$20.50 
` 7818 ad 
} �\ 
� \\ INVF''T IN: 
1,000 GALLON PRECAST 
\\ \\ ✓ '� ` \ / �, / �`\ - CONCRETE DOSE TANK PO DETAILS > 3 I 
___------------- -- - - 7818 RIM ELEV. 7820.Od SHO ON SHEET C7.1 
/ LOWER LEVEL FLOOR \ - 
ELEVATION 7824.E DWER .6 I 
:\ \ ,\ / \, %� ,_ -f � TIN• 7817 i �! 
/\\ FROM ARCHITECTURAI, PLANS------- 
\\ \� ------------RIM — D-NITEUNIT i I1 1 
r — — — — — ' \ — \ \\ _ - 7820 INVERT oUT$781s�s+20 
a I 
450 
+26 
\\ \ \ \ `\ ck �� +22`�- ----- - — — 
PROPOSED EDGE OF ASPHAL j/,, \\\` 0 7----------- _ 
7822 i i� k E 
1 
` 1 
patio 
4"PVC 
\ / / +28 �\ P 00' AT 2%�SZ,OP \ tS� 
1 1/2 (IPS) HDPE 160 psi SEWER SERVICE ' 
p a t i o INVERT OUT 7820.00 CONNECT TO EXISTING 
\ `/ +30 1 o w f l r ` - \ \ PRESSURE SEWER 
7884. - _ - - +24 ! \ _ — _ \ 6.5' COVER } 
line of_--- 
h 
\ \ - +26 
7828 
\ \ 7 6 
+281 \ \ 3 
C4 
- \ \ 7830 a 
_ ---- -- it 
= 
\\ \\ \\ t.o PP r ,'tine of ! - \ - -- ---- - E 
' \\\.0 310 ------ �- 5` swate_ ! ,_ 
\\ 7832 
L \ `\ �\ 
32 
! 1 RSR EASEMENT 
EDGE OF DIRT ROA ``� •° \ `� 2� ! SEE NOTE 5d ON PLAT 
` '= ------------- ---- —_ a__ /, CONNECT TO EXISTING i I ( I ; I •. 
d j` t^ O-E}r�-� +34 ,.- 1 112 (IPS) HDPE SERVICE I t Q I 
` +42 + \ ` ! /// - _ _ �/ WITH SCH80PVC i 
40 \\\ \ \ +34 34.5 /,- BARBED FITTING 
\ - _ 7826fc 
lS \ 
` dr stack rock T o I 
rtarnrn wa11 \ y ❑ I 
4-0 H h t. max. X, \ \ . _ PRESSURE SEWER CLEANOUT ( , 
----------------- 
\ _ 
\ _ 
840 
�`` ` \ ``\ 1.926 _ACRE&-- 
2 
------ i, 
FIRE HYDRAN 
;c) E 
A 4^34'40' 
R=125,00' 
L'=14 0 , 8 9THESE PLANS ARE TO DEPICT THE 
T=78.99 WASTEWATER SYSTEM ONLY. ALL 
C LE N =13 3.5 5' ARCHITECTURAL PLANS ARE TO BE PROVIDED 
BRG=S 46^06'53' E 
fine residential design 
III' I11 f 
the ke,ating' artnershi ,p Ppc 
801 Twelfth Street, Golden Colorado 80401 
wmkeathg-WtrrrWpzom 303-278-8840 
.' 
n � 
=a 
ri 
TONAL E 
11