HomeMy WebLinkAbout875 Cordillera Wy - 210712204009INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2188-02 BP NO. 14147
OWNER: TOM KOEHLER PHONE: 970-926-0323
MAILING ADDRESS: P.O. BOX 6714, AVON, CO 81620
APPLICANT: GARY MARNER PHONE: 970-926-3093
SYSTEM LOCATION: 875 CORDILLERA WAY, EDWARDS, CO TAX PARCEL NO. 2107-122-04-009
LICENSED INSTALLER: REYNOLDS CORPORATION, BUZZ REYNOLDS LICENSE NO. 63-02 PHONE: 970-949-4226
DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 4 BEDROOM RESIDENCE
1500 GALLON SEPTIC TANK, 1488 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 48 INFILTRATOR UNITS, AS PER ENGINEER DESIGN REVISIONS
DATED 6/20/02. ' 20 UZ
SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESI , WITH A CLEANOUT BETWEEN THE TANK AND THE HOUSE. BE SURE TO MAINTAIN
ALL APPLICABLE SET BACK REQUIREMENTS AND DO NOT INSTALL IN WET WEATHER. CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND
THE DESIGN ENGINEER FOR FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION, OR WITH ANY QUESTIONS
REGARDING THE INSTALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS
BEEN INSPECTED AND APPROVED.
ENVIRONMENTAL HEALTH APPROVAL: 69m= DATE: MAY 17, 2002
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL
AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM
IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 1488 SQUARE FEET (VIA 48 STANDARD INFILTRATOR UNITS )
INSTALLED CONCRETE SEPTIC TANK: 1500 GALLONS IS LOCATED 80 DEGREES AND 30 FEET INCHES
FROM THE CLEANOUT ON THE NORTH WEST SIDE OF THE HOUSE.
COMMENTS: THE FTNAT. TNRPFCTTONS WFRF DONE, RY RAYMOND MERRY OF EAGLE COUNTY ENVIRONMENTAL HEAL H
AND THE DESIGN ENGINEER ON JULY 11, 2002. THE ENGINEER'S FINAL CERTIFTCATTON WAS RECEIVED ON
AUGUST 19, 2002. THIS SYSTEM IS LARGE ENOUGH TO ACCOMMODATE A FOUR BEDROOM RESIDENCE.
ANY ITEM NOT MEETING REQUIREMENTS WILL BE F R ROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS
COMPLETED.
ENVIRONMENTAL HEALTH APPROVA DATE: AUGUST 19. 2002
v
;Incomplete Applications Will NOT Be Accepted
( Plan MUST be attached)
ISDS Permit #1
Building Permit #
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. O. BOX 179
EAGLE, CO 81631
Eagle (970)328-8755, Fax (970)328-0349, E1 Jebel (970)927-3823
****************************************************************************
* FEE SCHEDULE
* APPLICATION FEE $350.00
*. THIS FEE INCLUDES THE ISDS PERMIT, SITE EVALUATION (PERCOLATION TEST,
* SOIL PROFILE OBSERVATION) AND FINAL INSPECTION
* ADDITIONAL FEES MAY BE CHARGED IF A REINSPECTION IS NECESSARY, OR A
* PRE -CONSTRUCTION SITE VISIT OR CONSULTATION IS NEEDED
* REINSPECTION FEE $47.00, PRE -CONSTRUCTION SITE VISIT FEE $85.00
* MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
PROPERTY OWNER:
MAILING ADDRESS • P. o. Bo x "7 i y A o� o,v �n g I &- z. a PHONE. 9 zf-- o_3z3
i»ARN a CcNsr,2ucTca.s �,vc,
APPLICANT/CONTACT PERSON: GARV PHONE: qZC,-36`►3
-LICENSED SYSTEMS CONTRACTOR : %� E yN o t. p s c o R P. PHONE: 9"yf
COMPANY/DBA : e-Alf ADDRESS: p 0- gb�` -7 3 B � A axv
***************************************************************************
PERMIT APPLICATION IS FOR: X NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
SIS
Legal Description: for 9 Fic i.vy /ter- z C"o,eoi c«e�4 wA 9J
Tax Parcel Number: Zror7 i Z-Z-o 5/ 0-09 Lot Size • Z 37
Physical Address: Z;j�.-7 S A4 Z-Z- ",V �'o,e {y/ LLE �2A
BUILDING TYPE: (Check applicable category)
GX) Residential/Single Family
( ) Residential/Multi-Family*
( } Commercial/Industrial*
Number
Number
Type _
of Bedrooms. U
of Bedrooms
*These systems require design by a Registered Professional Engineer
TYPE OF WATER SUPPLY: (Check applicable category)
( ) Well ( ) Spring ( ) Surface
( Public. Name of Supplier: E2w s v
APPLICANT SIGNATURE: Date: / S © Z
AMOUNT PAID: RECE I PT #: -� I 7 DATE:
CHECK #: I CASHIER:
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX (970) 328-8788
TDD: (970) 328-8797
TOLL FREE: 800-225-8136
www.eagle-county.com
EAGLE COUNTY, COLORADO
Date: June 25, 2002
TO: The Reynolds Corporation
FROM: Environmental Health Division
Raymond P. Merry, REHS
Director
RE: Reissuance of Individual Sewage Disposal System Permit No.2188-02. Tax
Parcel # 2107-122-04-009. Property Location: 875 Cordillera Way, Edwards,
CO., Koehler residence.
Enclosed is your ISDS Permit No. 2188-02 and a field copy of the engineer design stipulated on
the permit. It is valid for 120 days, or for the duration of your current building permit for this
property. The enclosed copy of the permit must be posted at the installation site. Any changes
in plans or specifications invalidates the permit unless otherwise approved. Please note any
special requirements that may have been added to the design by this department.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County Environmental Health
must also view the installation prior to back filling. Please call well in advance for your
final inspection. Your TCO will not be issued until our office receives this certification
from the engineer, and views the installation.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements. Please
notify this office if you have not been contracted to perform this installation.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
LKP Engineering, Luiza Petrovska
OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX (970) 328-8788
TDD: (970) 328-8797
TOLL FREE: 800-225-8136
www.eagle-county.com
EAGLE COUNTY, COLORADO
August 19, 2002
Tom Koehler
P.O. Box 6714
Avon, CO 81620
Raymond P. Merry, REHS
Director
RE: Final of ISDS Permit #2188-02, Tax Parcel #2107-122-04-009. Property
location: 875 Cordillera Way, Edwards, CO.
Dear Mr. Koehler:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,
Janet Kohl
Eagle County Environmental Health Department
ENCL: Informational Brochure
Final ISDS Permit
cc: files
OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX (970) 328-8788
TDD: (970) 328-8797
TOLL FREE: 800-225-8136
www.eagle-county.com
EAGLE COUNTY, COLORADO
Date: May 17, 2002
TO: The Reynolds Corporation
Raymond P. Merry, REHS
Director
FROM: Environmental Health Division
RE: Issuance of Individual Sewage Disposal System Permit No.2188-02. Tax Parcel
# 2107-122-04-009. Property Location: 875 Cordillera Way, Edwards, CO.,
Koehler residence.
Enclosed is your ISDS Permit No. 2188-02 and a field copy of the engineer design stipulated on
the permit. It is valid for 120 days, or for the duration of your current building permit for this
property. The enclosed copy of the permit must be posted at the installation site. Any changes
in plans or specifications invalidates the permit unless otherwise approved. Please note any
special requirements that may have been added to the design by this department.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County Environmental Health
must also view the installation prior to back filling. Please call well in advance for your
final inspection. Your TCO will not be issued until our office receives this certification
from the engineer, and views the installation.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements. Please
notify this office if you have not been contracted to perform this installation.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
Marcin Engineering, Tony Donovan
OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179
LY�r CIYLl11VGGfL 1IYt7 11''il1
rout JZI J.J
I1I '' Engineering, Inc.
CNIL/GEOTECI LAICAL
,August 19, 2002
Mr. Tbomas Koehler
892 Harbor Island
Clearwater, FL 33767
Dear Mr. Koehler.
RE: Inspection of Septic System Installation
Lot 9, Cordillera, Filing No's l & 2
0875 Cordillera. Way
Eagle Comity, Colorado
Project No. 01191- ISDS Permit No. 2188-02
At the request of Mr. Cxary Marner, on July 11, 2002, we visited, the construction site on Lot 9,
Cordillera Filing No's 1 & 2, 0875 Cordillera Way, Eagle County, Colorado. The purpose of out site
visit was to Wspect the installation of the septic system.
They installed the system in overall compliance with the septic system design., Dravving No.
011.91 SD.DWG, dated June 20, 2002. They installed a 1.500-gallon, two cotxtpartments, precast, concrete
septic tank. The septic tattle. had "T's" in both compartments_ Two sewer lines came out of the house from
the north side of the building as shown. on the sketch. A cleanout was installed for each line between the
house and the tank, which is also shown on the as -built sketch..
Forty eight, Standard Inf.ltrator Chambers were installed in eight trenches with. 6 infiltrators in
eaeb tre-tech. The infiltrators were connected with serial distribution and were 9 feet on center. In the .first
and last itffiltrator of each trench, inspection ports were installed. The effluent line was 4-inch SDR 35
PVC.
The location of'the septic tank and the location of the line coining into the hnrst row of infiltrators
was different frora the origiaal dravviag. The attached as -built sketch shoves the new location of the tank
and the lute coming into the first row of infiltrators.
Please reference the as -built sketch for the precise location of the tank and leach field area.
If you have any questions, please do not hesitate to call..
LKP Engineer'
�ui�zaPetro k,;PE �»
President'
Enclosure '�`�_ t1"'.
cc: Gary Manner at%"*97t attd ECBF); Department at 970-328-0349
01191.05i.doa
P.0. Box 2837, Edwards, CO 81632, (970) 926-9088 .Tel., (970) 926-9089 Pax
^.I Ir-A 0_nM(n'7 Mrlk1 MCI. -2nnM TM. Cllf"I C rill Ik ITV Ck 11 1 1 1r—^1 TI 1
I ` 1
/ t
=r 4, tf r If r
:''oo;lA T•7t' ?. p/ S� oi.� .•:": A.
I.uT 17
C, 5.016 A. o �OT3� ^:$' f.994 Ac.
/ I e T 0455� .�� �, i 0930
Wa
W t �09 AC 'Zl1�.3. , t,23 Ac. /•e 7\ ! /
ii sec (0340.
u!T r `� �,•9d 9/'6 F �
2532AC �,/e• LOT 16
13 1` o A .i1 'e'sr ,;o6oSj `\ ,,• `? (3. 112 Ac.
N .�' �' \`, r• �En LIEN}fi �T.i �y Co J,0910
t
IN
u
V 1/ yS 9f l
t
la p
• Ism „'' "� s°O
LOT
.b0 S '^ � •P � �. LAiNi:•) f A51 Ml bl 6 ,� OJ t UT
TOT
Vic
3 eeo
70,
101
LOT 14
•f \ /
"•J
OK N 5✓ACT
Q
•• /
TRACT A \ y '
LOT I.�
OVEN SWCt 57'l Ac
N�
v
z
huff Ina.urr.
�
fl...lnuy
i
C+•riGl.+
a.
/.1 iFrrl.
Gj5
%P • C?! 1
150.37
c
�4!•S4. 297.60 - -- --
� 02 53F W
C2 )TAin" lu I sociates, hx
� n $ply1W CREEK ROAD �.......... .l,Kuwl..,.�.& As.....»�.�m.....�..
A�8 v� hM1 Y.1NlL ISM Ft NiWGTON'1A1.0-11 Mj 11, FF
.h t0M[NI IANTNERS
7/01/88 -^88/138_ -.
LKP ENGINEERING, INC.
P.O. Box 2837
Edwards, CO 81632-2837
(970) 926-9088
Fax (970) 926-9089
PERCOLATION TEST RESULTS
Client: Thomas Koehler Location: Lot 9, Cordillera Filing No's 1 &2
892 Harbor Island 0875 Cordillera Way
Clearwater, FL 33767 Eagle County, Colorado
Project No.: 01191
P-1
P-2
P-3
TIME/DEPTH
16", 40"Overall
22", 40"Overall
21", 41" Overall
12:10
6-8/16"
5"
4-8/16"
12:20
8-8/16"
2"
6"
1"
6"
1-8/16"
12:30
9"
8/16"
6-8/16"
8/16"
7"
1"
12:40
9-4/16"
4/16"
6-12/16"
4/16"
7-12/16"
12/16"
12:50
9-8/16"
4/16"
7-4/16"
8/16"
8-8/16"
12/16"
1:00
9-12/16"
4/16"
7-12/16"
8/16"
9-4/16"
12/16"
1:10
10"
4/16"
8-4/16"
8/16"
10"
12/16"
PERC RATE
40 MIN/INCH
20 MIN/INCH
13.3 MIN/INCH
AVG PERC
25 MPI
Average Percolation Hole Diameter: 12 Inches
Holes Dug and Presoaked: June 12, 2002
Test Run: June 13, 2002
By: Peter Petrovski
Soil Profile: 0 - 1.5'- Silty Sandy Topsoil
1.5 - 9'- Brown, Silty Gravelly
Sand
No ground water encountered
LKP ENGINEERING, INC.
P.O. Box 2837
Edwards, CO 81632-2837
(970) 926-9088
Fax (970) 926-9089
PERCOLATION TEST RESULTS
Client: Thomas Koehler Location: Lot 9, Cordillera Filing No's 1&2
892 Harbor Island 0875 Cordillera Way
Clearwater, FL 33767 Eagle County, Colorado
Project No.: 01191
P-1
P-2
I P-3
TIME/DEPTH
16", 40"Overall
22", 40"Overall
2111,4111 Overall
12:10
6-8/16"
5"
4-8/16"
12:20
8-8/16"
2"
6"
1"
6"
1-8/16"
12:30
9"
8/16"
6-8/16"
8/16"
7"
1"
12:40
9-4/16"
4/16"
6-12/16"
4/16"
7-12/16"
12/16"
12:50
9-8/16"
4/16"
7-4/16"
8/16"
8-8/16"
12/16"
1:00
9-12/16"
4/16"
7-12/16"
8/16"
9-4/16"
12/16"
1:10
10"
4/16"
8-4/16"
8/16"
10"
12/16"
PERC RATE
40 MIN/INCH
20 MIN/INCH
13.3 MIN/INCH
AVG PERC
25 MPI
Average Percolation Hole Diameter: 12 Inches
Holes Dug and Presoaked: June 12, 2002
Test Run: June 13, 2002
By: Peter Petrovski
Soil Profile: 0 - 15- Silty Sandy Topsoil
1.5 - 9'- Brown, Silty Gravelly
Sand
No ground water encountered
LETTER OF TRANSMITTAL
TO:CC>LAM3� DATE: z'� t' MCI JOB NO:
��r ATTENTION: Al
RE:
WE ARE SENDING YOU VIA: FAX ATTACHED PICKUP OR DELIVERY
DELIVERED BY: THE FOLLOWING ITEMS:
SHOP DRAWINGS PRINTS PRODUCT INFORMATION CHANGE ORDER
SPECIFICATIONS COPY OF LETTER
#COPIES
DATE
DESCRIPTION
JU.aF /3A
sNG.PC- §TQG
z o 2
G/ i �' --t.� �. rs �✓� r " G
THESE ARE TRANSMITTED AS CHECKED BELOW:
FOR YOUR APPROVAL REVIEWED BY MCI AS REQUESTED
FOR YOUR USE FURNISH AS CORRECTED REJECTED
REVISE AND SUBMIT
PRINTS RETURNED AFTER LOAN TO US
COPY TO:
COPIES
FOR REVISS AND COMMENT
-. - — ---- ... - e . .. era.._ weep__. nwn wens runs C--. ®7R_t19l2_Rd°YQ P-allselaw 67A-GnA.anftl
ISDS Permit # P �8 D Date i
T_anS Final InaRect4on
filet ass Form
Tank is i.t DD gal. Tank Material
Tank is located ft_ __L6degrees from Cll+�
_� (pas�wat l�m..slcl
Tank is located ft. and degrees fr
Tank set level. Tank lids within 8" of finished grade.
Size of field /YU ft2 � � units --?oQ lineal ft.
Technologyf�--F.-�
_/ Cleanout is installed in between tank and house (+ 1/100ft)
V"There is a "T" that goes down 14 inches in the inlet and wt l L
outlet of the tank:
et. and outlet is sealed with tar• -,tape, rubber gasket etc.
L-- k ;has two. compartments with the. A. -ar _r-;..cartment closest to
house.
l�ecahure: dstancerand relative
Depth of f ield. � 3_1' f t . _
'Soil interface raked. A)
__',, -Inspection portals at the .end of each trench_.
1---proper distance to setbacks.
L_�Chambers properly installed as per manufacturers specifications.
(chambers latched, end plates properly installed, rocks temoved from
trenches, etc.)
Type of pipe used for building sewer line S� , leach field sL�L ko
Other
UI/Inspection meets regUirements.
Copy form to installer's file if recoamle¢dations for improvement. Were
suggested.
ACTION TAKEN:
setbacks
Well Potable House Property Lake Dry Tank Drain
Water Lines line Stream Gulch__
Field 100
25
20
10
50
25 10
10
50
10
5
10
50
10 *
10
EAGLE- COUNT-Y-EW; RFAUTH
P.O. BOX 179
EAGLE, CO 81631
JOB
SHEET NO.
CALCULATED BY
OF
DATE
CHECKED BY DATE
SCALE
PRODUCTM-1(Single Sheen) 2rr-f (Padded) /�/®Mc., Gr;W, Mug. 01477. To OnW PHONE FULL FREE T-ffW 5-4iN9
2188-02 Tax #2107-122-04-009
JOB NAME Lot #9, Filing 1&2, KOEHLER
Cordillera Subdivision
875 Cordi 7 i ---
JOB NO..,�
ION
STARTED
� 1 _
DATE COMPLETED
DATE BILLED
I MAE
%
.
1111
w0j,w,,wr0E=
gill _[__ 0
1
i
�� I Ili l ail.. ►i
!
��1 r1-11 W.1;
Z/1i
1
-
1
JOB COST SUMMARY
,s
1
I '
TOTAL SELLING PRICE
-.
101111 sum
m
WIN
TOTAL MATERIAL
_■j
Ord
s
I! III iippj
!"Elm
�■
_Al
MISC. COSTS
111121W.6I �00#W,
1.-■
IN WrA WX
TOTAL JOB COST
ME
GROSS PROFIT
_■
•LESS:OVERHEAD
•
_■
BoaT/LDER Produ.x zia ��� $ 8 gyp' /�l� �o F�wI �� �(� � S '� wll ��3�� /jo J OLDER . ��;� _
(a)
Recycled Content
10% Post -Consumer
7 7-
Y-
_
-
Y F-
z
s t -
t
--
- -
cc _-
CIL
_-
Z-_ - --
---
--
_ i
_lr4lb
Zi
4z� c - Lx_ _- z
-� --` _-
FN Q
r4io lot
CC
- - Q
cc _ --
=.o�
cc
- _ -
z�
�ADcc
CL °-
p00�R s'� _
•......
t�p`t;.• ?ETq, .lF�
r •
- DA M VV -20-2i. 02- 3 -
DRAwNG Nam
4
-
-
> -
r.
z. _
-i
-
� s
2-
$'-
—