HomeMy WebLinkAbout737 Granite Springs Trl - 210715401001INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 213 8-01 BP NO. 13 877 OWNER: TIM AND KATHRYN ELLER PHONE: 214-981-6100 MAILING ADDRESS: P.O. BOX 19900, DALLAS, TX 75201 APPLICANT: SUMMIT HABITATS, DANA PHONE: 970-926-1793 SYSTEM LOCATION: 737 GRANITE SPRINGS TRAIL, EDWARDS, CO TAX PARCEL NO. 2107-154-01-001 LICENSED INSTALLER: DAVIS EXCAVATING, JUSTIN AHRING LICENSE NO. 27-01 PHONE: 970-926-3788 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 7 BEDROOM RESIDENCE 2000 GALLON SEPTIC TANK, AND A 1000 GALLON ELECTRIC LIFT STATION WITI4 AN AUDIO AND VISUAL ALARM SYSTEM, 2625 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 85 INFILTRATOR UNITS, AS PER ENGINEER'S DESIGN SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 5/29/01, WITH A CLEANOUT BETWEEN THE TANK AND THE HOUSE, AND INSPECTION PORTALS IN EACH TRENCH. ANY WATER FEATURES INSTALLED ON THE PROPERTY MUST BE LINED AND LEAK PROOF, AND OUTSIDE OF ALL APPLICABLE SET BACK REQUIREMENTS AS LISTED ON THE DESIGN. RAKE ALL TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS, AND DO NOT INSTALL IN WET WEATHER. THE ALARM SYSTEM MUST BE TESTED PRIOR TO CERTIFICATION. CALL EAGLE COUNTY ENVH2ON- MENTAL HEALTH FOR FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION OR WITH ANY QUESTIONS. THE LEACH FIELD AREA MUST BE FENCED OFF TO PREVENT ANY CONSTRUCTION TRAFFIC IN THE AREA. DO NOT STORE ANY CONSTRUCTION MATERIALS OR ALLOW ANY LANDSCAPING OVER THE LEACH FIELD. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROVAL: WILLIAM CARLSON DATE: NOVEMBER 1, 2001 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. " 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 2625 SQUARE FEET NIA 85 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN 1 INSTALLED CONCRETE SEPTIC TANK, 2000 GALLONS IS LOCATED 54 DEGREES AND 48 FEET 6 INCHES FROM THE CLEAN -OUT ON THE EAST SIDE OF THE HOUSE, AND A 1000 GALLON ONE COMPARTMENT TANK FOR THE ELECTRIC LIFT STATION ADJACENT TO THE MAIN TANK. COMMENTS: FINAL INSPECTIONS WERE DONE BY LAURA FAWCETT AND THE DESIGN ENGINEER ON AUGUST 8, 2003. THE FINAL ENGINEERING CERTIFICATION WAS RECEIVED ON JANUARY 9, 2003. THIS SYSTEM IS LARGE ENOUGH TO ACCOMMODATE A SIX BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. r�. ENVIRONMENTAL HEALTH APPROVAL(C� Lt'/l_ l J DATE: MARCH 12, 2003 incomplete Applications Will NOT Be Accepted (Site Plan MUST be attached) ISDS Permit # �L(5 a -() 1 Building Permit # ! °�iR °�i r) APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 Eagle (970)328-8755, Fax (970)328-0349, El Jebel (970)927-3823 * FEE SCHEDULE * APPLICATION FEE $350.00 * THIS FEE INCLUDES THE ISDS PERMIT, SITE EVALUATION (PERCOLATION TEST, * SOIL PROFILE OBSERVATION) AND FINAL INSPECTION * ADDITIONAL FEES MAY BE CHARGED IF A REINSPECTION IS NECESSARY, OR A * PRE -CONSTRUCTION SITE VISIT OR CONSULTATION IS NEEDED * REINSPECTION FEE $47.00, PRE -CONSTRUCTION SITE VISIT FEE $85.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" *****************-*�!********************************************************** PROPERTY OWNER: i M t VAJ(Vv� vt 4" it � C v- MAILING ADDRESS: ol 410 o �� b e7 �x � PHONE: 2 14 1161 117 11)V APPLICANT/CONTACT PERSON: �,vyvXvv t �`6 A^A_7 PHONE: LICENSED SYSTEMS CONTRACTOR: A skvc, J-ow( 4 PHONE: COMPANY/DBAAV&V�a �,�cC�y�n-I'� ADDRESS : *************************************************************************** PERMIT APPLICATION IS FOR: (>() NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIffVI--DUAL SEWAGE DISPOSAL SYSTEM:�j Legal Description: l�fi { �l� � 1 n j 2 J I , C(?Zd A /`t 'f� Tax Parcel Number: 2 {� "7rK-1 _ d 1 —0 0 --Lot Size: lo•�ZJ� Physical Address: 737 �o t4- 5V vtvi4S 1 r A e , YMCl BUILDIN TYPE: (Check applicable category) Residential/Single Family Number of Bedrooms Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type *These systems require design by a Registered Professional Engineer TYPE OF WATER SUPPLY: ( ) Well ( ) Public Name APPLICANT SIGNATURE: (Check applicable category) Spring ( ) Surface of Supplier: fA4 LF- Y4-tye4`_ Date: 01 ? o *************************************************************************** AMOUNT PAID: RECEIPT #: DATE: CHECK #: �5 0 1 i % CASHIER: DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO March 12, 20.03 Raymond P. Merry, REHS Director Tim and Kathryn Eller P.O. Box 1.9900 :Dallas, TX 75201 " - RE:- Final of ISDS Permit #2138-01 Tax- Parcel 921-07-154-01-001 Property location:, 73 7 Granite Springs.Trail,_Edwards,.CO. Dear Mr. & Mrs. Eller: This letter is'to,inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your.records. This permit does not indicate compliance withany other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Eagle County Environmental Health Department ENCL: Informational Brochure Final ISDS Permit cc: files OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 Community Development Department (970)328-8730 FAX (970) 328-7185 TDD .(970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com EAGLE COUNTY, COLORADO Date: September 19, 2001 TO: Arena Excavating FROM: Environmental Health Division Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Issuance of Individual Sewage Disposal System Permit No.2138-01. Tax Parcel # 2107-154-01-001. Property Location: 737 Granite Springs Trail, Edwards, CO., Eller residence. Enclosed is your ISDS Permit No. 2138-01 and a field copy of the engineer design stipulated on the permit. It is valid for 120 days, or for the duration of your current building permit for this property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer, and views the installation. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files LKP Engineering, Luiza Petrovska DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO Date: November 1, 2001 TO: Davis Excavating FROM: Environmental Health Division Raymond P. Merry, REHS Director RE: Issuance of Individual Sewage Disposal System Permit No.2138-01. Tax Parcel # 2107-154-01-001. Property Location: 737 Granite Springs Trail, Edwards, CO., Eller residence. Enclosed is your ISDS Permit No. 2138-01. Please obtain a field copy of the engineer design stipulated on the permit from the engineer or the general contractor. It is valid for 120 days, or for the duration of your current building permit for this property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer, and views the installation. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files LKP Engineering, Luiza Petrovska OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 CIVIUGEOTECHNICAL January 2, 2003 Mr. Matt Shoulders Summit Habitats P.O. Box 1829 Edwards, CO 81632 Dear Matt: RIE: Inspection of Septic System installation Trot 13, Block 5, Cordillera Filing No. 34 737 Granite Springs Trail Eagle County, Colorado Project No. 9947 - Permit No. 2138-0I At your request, and at the request of Mr. Rick Filters with Davis Excavating, on July 30, and August 8, 2002., we visited the construction site on Lot 13, Block 5, Cordillera Filing No, 34, 737 Granite Springs Trail, Eagle County, Colorado. The purpose of our site visits was to observe the installation of the septic system. They installed the system in overall compliance with the septic system- design, Drawing No. 99475D.DWCT, dated May 29, 2001. They installed a 2000-gallon, two compartments, precast, a concrete, septic tank, and a 1000-gallon one compartment, concrete, septic tank. We understand that in the second septic tank, they installed a Zoeller Pump, Model 292. As of today, the pump and the alarms had not been tested. The effluent line from the pump tank to the first infiltrator of the leachfi.eld was a total distance of 346 feet. The effluent line was 2-inch diameter sch4O PVC. About 160 feet of the effluent line crossing under the driveway was dou'ale encased in a 5-inch diameter, C900 pipe. The Eighty -.five, Standard lrf,ltrator Chambers were installed in eight trenches, as shown on the attached sketch, The first five trenches (near the road) contained eleven infiltrators each, and the last three had ten infiltrators each. The infiltrators were connected with serial distribution. In the first and last infiltrator of each trench, inspection ports were installed. Horizontal distance from center to center of the trenches, was 9 feet or more. If you have any questions, please do not hesitate to can. Sinoerely, LKP Engineering, Luiza Petrovska, PF President cc: Ms. Laura Fawcett'. Enclosure C ;IWP 10-LXP19947osI-pump.wpd Environmental Health Division, fax: 328-0349 P_OA2 Ox 2837, Edwards, CO 81632, (970) 926-9088 Tel, (970) 926-9089 Fax 7Q grlt-A ' WT Vd\1T?-ggMTnM-4 A\A-1 C.QMaQ7r-M) C t+, 1CM cnn7 ICT :On j S �f MMIT HABITATS �w-11_1COL%.rORATED qq q May 6, 2003 LIP Engineering, Inc., Attn: Luiza Petrovska P-0,130X 2837 Edwards; CO 81632 Dear Luiza, Enclosed please find a plan `view of the mechanical room at the Eller Residence 737 Granite Springs Trail, where the septic alarm system'is located. We will have Thul .Electronics interface with the alarm to send it throtigh the emergency speaker system. ,Also find a copy of a letter signed by Davis excavation verifying.the operation of the septic system. T believe you need these items to get our final septic approval with the count. If you have any questions please call me at 977-6611. Site Superintendent, Summit Habitats, Inc, Enclosure 4 , CUSTOM BUILDERS + RESIDINTIAL &. COMM ERCIACCONSTRUCTION 27 MAIN •S-I UFT « SU172 200 + RO. Box 1829. &)WAws, CO 83632 - PH 970.-926r1743 + t;x 970-926-48S1 * sumklab@snowcap.nn i,fA ��1F2.-t ')KIT L)KM.-M-1KITL)KM —N1 CO0007CMl C C4, -CM CMM7 )CT ton I,** - #,A* .IMT P"TN7-AWTqM-4 v Re; tiller lift station (sewer) verification, 5-2-2D03 Performed by Rick Filter of Davis Excavating Lic.* 53-03 1, Rick Filter verify that the lift station at the Eller residence operates and complies to the Eagle County specification, per LKP design. Rick Filter, Davis Excavating r� i -1- 4fa �C14-dJ 1 ')KIT MKITMM-MKITC1hl7 JlA'l COMC07f:MJc Ci,'Cn crn7 lrTlnn �i ISDS Permit # on138-Date ISDS Final Insvection 2000 Co�leteness Form Tank is gal. Tank Material ,�n ✓/ Tank is located P1ft. and `5 4 degrees from (permanent landmark) 4 Tank is located ft. and degrees from (permanent landmark) . ✓ _ V Icy ��� ��ank set level. '~Tank lids within e" of finished grade. Size of field ft2 as units lineal ft. ' r°�J a Technology�'�`� 1---'Cleanout is installed in between tank and house(+ 1/100ft). l---- There is a "T" that goes down 14 inches in the inlet and outlet of the tank. OLUI#Afi``3 wn- let and outlet is sealed w h ta��_ r t perubber gasket- V Tank has two compartments with the larger compartment closest to the house. /.Measure distance and relative direction to field. L. ti V Depth of field 3 ft. Soil interface raked:— )Z4 I Z, 4.4 Inspection portals at the end of _each trench.. Proper distance to setbacks. r%"Chambers properly installed as per manufacturers specifications. (Chambers latched, end plates properly installed, rocks removed from trenches, etc.) s� Type of pipe used for building sewer line leach field Other Inspection meets requirements. Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: ' Setbacks Well Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Field 100 25 20 10 50 25 10 10 Tank 50 10 5 10 50 10 * 10 EAGLE --COUNTY ENV. HEALTH P.O. BOX 179 EAGLE, CO 81631 PRODUCT 2De.1 (Single SAem) 2115-1 (PaIM) ®® kt.. Grdon. Mass. 01471. To Order PHONE TOLL FREE 1-8*225-M JOB SHEET NO. OF_ CALCULATED BY DATE CHECKED BY DATE 2138-01 Tax#210715401001 JOB NAM.E.Lot #1 3,Block5 ELLER Filing 34, Cordillera JOB NO.0 �3gr) q 1. LOCATION f --- I ) BILL TO DATE STARTED DATE COMPLETED DATE BILLED �l /� ram^ ` ^ �� <2 �/Zl i `o J- f U1 �- Gti ✓1 j d'- 1e� —- ' I/ I {S % 2 { L. Jm cu /45 ' �J0 //l�/L /`// / �L %`o�NX U -�/ , � ' " "W _fe ��V( e6s� /elf / L-6 - f AI J j o JOB COST SUMMARY lL2 O� !� LL // ' off' a doo ✓L W �1 a� TOTAL SELLING PRICE r 0D0 �2f N` TOTAL MATERIAL TOTAL LABOR 8 !e z -' e. 45�. Q �s - INSURANCE SALES TAX MISC. COSTS b K +rw jzv<. ct' TOTAL JOB COST ►(q GROSS PROFIT �� b LESS OVERHEAD COSTS OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 JOB FOLDER Printed U.S.A. -4 zpm :17 V I 1 �'. r - �. I 1 —. 5 s - ( _ r W , - L '4 J '-. T -31Q' R- r _ „- ;. s:.,•� .. , ... _...... �, :,' - : , _ ..tt�C� ,: _ . �..'wl ; :... Nn7r'• rraF* eanv>- renrK ,s PRnnur.jrn av rnvr eNn rnn►ra;*rc -F GROSS NET DISCHARGE l WE GHT VCr M U E VOLUME PER CYCLE TANKAlD . 1050 GAL. 'goo GAL. - Variable 17.62 gallons 9300 : LBS -per vertical inch Y/Tw&col NV: yogi _ f DA M 05-29-2001