HomeMy WebLinkAbout285 Little Andorra - 210701303012INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 ORIGINAL PERMIT NO. 1937-99 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. ALTERATION PERMIT NO. 207OA-01 BP NO. 12906 OWNER: ROBERT SHAW PHONE: 9847-317-3777 MAILING ADDRESS: 25 TRI STATE OFFICE CENTER, SUITE 100, LINCOLNSHIRE, IL 60069 APPLICANT: GAYLE GRIDER, PHONE: 970-904-1274 SYSTEM LOCATION: 0285 LITTLE ANDORA, EDWARDS, CO TAX PARCEL NO. 2107-013-03-012 LICENSED INSTALLER: GRAEF CONSTRUCTION OF VAIL, ROBERT GRAEF LICENSE NO. 5-01 PHONE: 970-926-2059 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 5 BEDROOM RESIDENCE EXISTING 1500 GALLON CONCRETE SEPTIC TANK, ADDITIONAL 217 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 7 INFILTRATOR UNITS, FOR A TOTAL OF 31 UNITS, AS PER ENGINEER'S DESIGN DATED 2/21/01. SPECIAL REQUIREMENTS: CONNECT ADDITIONAL ABSORPTION AREA IN SERIAL DISTRIBUTION TO THE LAST ROW OF INFILTRATOR UNITS AS DE- PICTED ON THE ENGINEER'S DESIGN DATED 2/21/01, WITH AN INSPECTION PORTAL IN THE TRENCH. PLEASE NOTE THE ADDITION OF ONE MORE UNIT ON THE PLANS. PLEASE CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE ENGINEER FOR FINAL INSPECTION, AND DO NOT BACK FILL ANY PART OF THE INSTALLATION UNTIL BOTH ENTITIES HAVE INSPECTED IT. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN APPROVED. 1 ENVIRONMENTAL HEALTH APPROVAL:d/-)WJh.a-'.I�,UIZ,/ .� DATE: MARCH 20, 2001 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 217 SQUAREFEET(VIA 7 INFILTRATOR UNITS AS PER DESIGN ) COMMENTS: THE INSTALLATION WAS TNRPFcTFD Ry THE ngsiGN jzNC_T IEEPt AND WILLIAM CARLSON ON 3-22-01 THIS SYSTEM IS NOW LARGE ENOUGH FOR A 5 BEDROOM RESIDENCE AND CONSISTS OFA 1500 GALLON CON R T SEPTIC TANK AND 961 SQUARE FEET OF ARSORPTTON ARRA CREDIT, VIA 31 INFILTRATOR UNITS ANY ITEM NOT MEETING REQUIREMENTS WILL 1 C CTED BE R ROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL DATE: MARCH 27. 2001 Incomplete Applications Will NOT Bp Accepted (Site Plan MUST be attached) i 9✓'7-g1 9 I D Permit # Building Permit # 13Ab U, APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 Eagle (970)328-8755, Fax (970)328-0349, E1 Jebel (970)927-3823 ************************************************************************** * FEE SCHEDULE * PERMIT APPLICATION FEE $150.00 * PERCOLATION TEST/SOIL PROFILE AND SITE EVALUATION FEE $200.00 * SITE VISIT/CONSULTATION FEE $85.00 * REINSPECTION FEE $47.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: ) ��J�'V! C.1 iL w— II _ n I L ' l MAILING ADDRESSAS : APPLICANT/CONTACT PERSON: LICENSED SYSTEMS CONTRACTOR: COMPANY/DBA: AtDRESS: PHONE: (W7- -, `/'71 HONE : 5b0 qV -g�j g PHONE: *************************************************************************** PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION (/-4LTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: Tax Parcel Number: �a'%' 015 ` D 3 Physical Address: Lot Size: BUILDIN TYPE: (Check applicable category) (X) Residential/Single Family Number of Bedrooms .5_ ( ) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type *These systems require design by a Registered Professional Engineer TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surface (�) Public Name of Supplier:GA�,Ui-' l`h� APPLICANT SIGNATURE: Date: *************************************************************************** AMOUNT PAID: %J~� RECEIPT DATE: CHECK #: P II CASHIER: U.3xZ'JI-/UG11 10:00 ''dIUyZb'JUbJ LKh' EN(nlNLENiNU 1NU HAUE III /b1 v March 23, 2001 Mr. Scott Turnipseed RE: Tuspection of Selrtic System Installation -,Alteration P.O. Box 3388 Shaw Residence Eagle, CO 81631 Lot 62, Cordilleara. Filbig No. 3 Vial Fax: 328-3901. Eagle County, Colorado Project No. 99177 - Permit No. 207OA-01 Dear Scott: At the request of Rob Graef of Graef Construction, on March ,22, 2001, we visited the construetion site on Lot 62, Cordillera Filing No, 3, Eagle County, Colorado. The purpose of our site visits was to inspect the alteration to the existing leacbfield. An additional trench, with seven standard infiltrators was installed on the downhill side of the existing leachfietd. An inspection point was installed in the last infiltrator of the trench. The depth of the trench was 36 inches, and the soil exposed in the trench was light, gfayish-brawn, clayey -gravelly sand. The infiltrators of'the new trench were connected with serial distribution to the existing leachfield with infiltrators. Horizontal distance from center to center of the trenches, was 9 feet or more. All piping was SDR-35, 4-inch PVC. The septic system for the Shaw Residence, now consists of one 1500-gallon, two compartments, precast, concrete, septic tank and 31 Standard Infiltrator Chambers in four three trenches, with, 12 infiltrators in each of the first two trenches and 7 in the last. If you have any questions, please do not hesitate to call. Sincerely, LKP Engineerb r iz Petrovska, President cc: Ms. Laura Fawcett, Eagle County Environmental Health Division, fax: 328-0349 C:1MyFla$Nrz) ¢ldoetWPDMSN99179oei2.wgd P 0 Rnv ).Q97 VA .-A r i a - n, r , , ..,� 4V,•,, ,guy, a«;, �uAuraao clo�� '6 (970) 926-9o88 Tel - (970) 926-9089 Fax Ism Permit # 2a7'5A -0 ( ISDS Final InaRection Completeness Form Tank is i5 gal. Tank Material' Date 3 - 22^ Q / Tank, is located ft. and degrees from (permanent landmark) ✓Tank is located O ft. and degrees from d� �o��D:Oe✓� ®ram '�'r/q/aJ (2pzmanent landmackj Tank set levell. Tank lids within 8" of finished grade. Size of field 2/7 ftt2 unit C/L)S'lineal ft. Technology Clew is i stalled in between tank and house(+ 1/100ft). There is a "T" that goes down 14 inches in the inlet and outlet of the tank. . Inlet and outlet is sealed with tar• -,_tape, rubber gasket etc. Tcink ;has two compartments with the l*arger...;.cQtnpaxtment closest to house. Measure, distance and relative directimn to ;:.field: Depth of f ield. 2- f t . --- e`) Soil interface raked. ^� Inspection portals at the.end of each trench.. Proper distance to setbacks. chambers properly installed as per manufacturers specifications. (Chambers latched, end plates properly installed, rocks 'removed from trenches, etc.) Type of pipe used for building sewer line , leach field '�,o/z-3 � Other Inspection meets requirements. Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: Setbacks Well Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Field 100 25 20 10 50 25 10 10 Tank 50 10 5 10 50 10 * 10 EAfiLE-£$$II HEALTH P.O. BOX 179 EAGLE, CO 81631 JOB SHEET NO. OF CALCULATED BY JZ'/20 0 DATE CHECKED BY "�` �� Y DATE SCALE INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1937-99 BP NO. 12906 OWNER: ROBERT SHAW PHONE: 847-317-3777 MAILING ADDRESS: 25 TRI STATE OFFICE CENTER, SUITE 100, LINCOLNSHIRE, IL 60669 APPLICANT: SCOTT TURNIPSEED PHONE: 303-449-8939 SYSTEM LOCATION: LOT # 62, FILING 3, CORDILLERA SUBDIVISION. EDWARDS, CO TAX PARCEL NO. 2107-013-03-012 LICENSED INSTALLER: GRAEF CONSTRUCTION OF VAIL, ROBERT GRAEF LICENSE NO. 71-99 PHONE: 970-926-2059 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 4 BEDROOM RESIDENCE 1500 GALLON SEPTIC TANK 750 SQUARE FEET OF TRENCH ABSORPTION AREA VIA 24 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN. SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED9/16/99. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. BE SURE TO MAINTAIN ALL APPLICABLE SETBACK REQUIREMENTS. DO NOT BACK FILL ANY PART OF THE INSTALLATION UNTIL THE ENGINEER HAS IN- SPECTED AND APPROVED IT. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTILL THE SEPTIC SYSTEM RECEIVED FINAL CER- TIFICATION. i ENVIRONMENTAL HEALTH APPROVAL: DATE: NOVEMBER 29, 1999 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 750 SQUARE FEET (VIA 24 INFILTRATOR UNITS PER DESTGN ) INSTALLED CONCRETE. SEPTTC TANK: 1500 GALLONS IS LOCATED DEGREES AND 28 FEET INCHES FROM THE NORTH EAST CORNER OF THE BUILDING. COMMENTS: ENGINEER FINAL CERTIFICATION RECEIVED AUGUST 7, 2000. THE TANK FOR THIS SYSTEM IS OVER —SIZED TO ACCOMMODATE A FIVE BEDROOM RESIDENCE, BUT THE LEACH FTFTD TS ONLY TARCF FNoHcg TO ACCOMMODATE FOUR BEDROOMS. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. J / ENVIRONMENTAL HEALTH APPROVALDATE: AUGUST 8, 2000 bb! b !! lbbb l i s bl 'J f J-JZb-yJMJ LKN ENUINLLMINU, 1NC PAGE U1 Lit c>u August 7, 2000 }: .f Mr. Scott ') urni s :'t:i; :, •: $85 Arapahoe Ave_ IP llation Boulder, Co 90302 a..- .. Bad+_ ,. •: ter; • ": • Prvj - 06ftit No. 1937-99 Dear Scott. At the request of G `'.• • :em. . ar3'' ► , , u gust 3, 2000'vis ' J •c�in site on Lot 62, Cordillera Filing No. 3, Eagle, The ado. + p Visits was to observe the i nstal lation of the septic system.; Inc y installed the Ws i.. 'com Hance vv :' '' k >� : �.. d d"ign, Drawing No. 991775U_i7WC,, dated Septem ` x Tl' stem w w .61i the above -named .:'. , :Y lle `o drawing, They installed a 150 N z. 'aptsm at-tmen ; • �'... •taztlt with two risers ©n the access openings of t ; tank .. - p h k,`' Xocated 28 b do, iftg. 'twenty four Standard'. bens were ik ..; .. n ' 4 • Both rows of trenches contained twelve infiltrators. "' - Were ° " �; "., � ., connect s • rstriition.1<rt the last infiltrator oi'each trench, inspection rCs;,, : k�orixontal te` Beater of the trenches, wits 9 feet or more. All piping v - -inch PVC. r�;:•; es was no more than 36 you haveany If y uestitrot hesitate to dill Q. Sincerely,r " LKP > gin+erin «m/ls+mrrt I A 7At Petrov., a President a 29528 080, F cc.: Ms, Heatherl13;m+ironmentai , fsOc 328-0349 U7rcminutcrv:U,yFlw\c+raddueWP64C81sBln .:. �•�s'. ,��:•.';<: P.O. Box 2837, Edwards ::..,f .... • • � 2 r '74) 926-9088 T"10'9f3$*t, B-inail: lkpcng@snowcap.net Inuamplete"Applications.Will NOT Be Accepted ,(Situ Flan MUST be attached) ISDS Permit # M% - q % Building Permit # 1.2-q APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE. -.EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 3 - 27-3823 (Basalt) * PERMIT APPLICATION F $150.00 PERCOLATION TEST FEE $200.00 * MAKE ALL REMITTANC AYABLE'.TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: V\A"- .Z -3 -" L CC - MAILING ADDRESS: �-- i71EF t Dv �-A vf c�L4vL,tV.r.� 6I PHONE: -Wl �1jb3 APPLICANT/ CONTACT - PERSON : PHONE: 4 9) �3 � LICENSED SYSTEMS CONTRACTOR: -L 'a ��' ��`� PHONE: �z� �S COMPANY/ DBA : ADDRESS: *************************************************************************** PERMIT APPLICATION IS FOR: (>() NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: L"d �- o-, Tax Parcel Number • �� 5 Y1 b L '3.0 _>,,y t 2-- Lot Size: Physical Address: BUILDING TYPE:. (Check applicable category) (*Residential/Single Family Number of Bedrooms 4h- ( ) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surface (�) Public Name of. Supplier: hC��vZ��✓�- *These systems require d Sign by a Registered Professional- Engineer SIGNATURE: Date: S AMOUNT PAID:, I S� - RECEIPT # : 1 `� DATE • < CHECK # : CASHIER 1937-99 Tax #2107-013-03-012 207OA-01 Tax #2107-013-03-012 Lot # 62, Filing 3 SHAW Lot #62, Filing 3, SHAW JOB NAME Cordillera Subdivision Cordillera Subdivision 0285 Little Andora, Edwards JOB NO. f A q6 � JOB FOLDER Printed In U.S. Recycled Content 1096 Post -Consumer