No preview available
HomeMy WebLinkAbout1016 The Summit Trl - 210716205002INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2034-00 BP NO. 13359 OWNER: KEN ULICKEY PHONE: 970-926-0292 MAILING ADDRESS: 277 ARBORETUM CIRCLE, WHEATON, IL 60187 APPLICANT: KINDLER CHASE PHONE: 970-926-1743 SYSTEM LOCATION: 5366 SUMMIT TRAIL, EDWARDS, CO TAX PARCEL NO.2107-162-05-002 LICENSED INSTALLER: ARENA EXCAVATING, STEPHEN JEWETT LICENSE NO.27-00 PHONE: 970-827-4221 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 6 BEDROOM RESIDENCE 2000 GALLON CONCRETE SEPTIC TANK, 1000 GALLON LIFT STATION TANK WITH AN ALARM AND DOSING VOLUME OF 338 GALLONS, 1134 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA A MOUNDED ENGINEER DESIGN WITH A PERIMETER AREA OF 8175 SQUARE FEET. SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 9/18/00. BE SURE TO MAINTAIN ALL APPLICABLE SET BACK REQUIRE- MENTS, AND DO NOT INSTALL IN WET WEATHER. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. DO NOT BACK FILL ANY PART OF THE STALLATION UNTIL THE ENGINEER HAS INSPECTED AND APPROVED IT. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN APPROVED.%�iD.j /� o�/ ENVIRONMENTAL HEALTH APPROVAL: N (J GLU L l o I DATE: SEPTEMBER 29, 2000 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED CONCRETE SEPTIC TANK: 2000 GALLONS IS LOCATED 171 DEGREES AND 34 FEET 6 INCHES FROM THE CLEANOUT ON THE EAST SIDE OF THE HOUSE. 1000 GALLON DOSING TANK ALSO TNSTAT.T.En- COMMENTS: THE FINAL INSPECTIONS WERE DONE BY LAURA FAWCETT OF ENV- HF.AT,TH ANTI TUF TIFSTGN FNG?INF ON JUNE 12-13, 2001. THE ENGINEER'S -FINAL CERTIFICATION AND AS —BUILT DRAWING WERE RFCFTVFn nN MAY 29, 2002. THIS SYSTEM IS LARGE ENOUGH FOR A•SIX BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. �' Bn � ENVIRONMENTAL HEALTH APPROVAL( G� u� DATE: JUNE 10 , 2002 e Applications V4:L1.1 ,NuT ne HccePt-=" WffTCT h4= Flrta!"}1R_C3) • ISDS Permit # �� Building Permit # — APPLICATIONT FOR INDIVIDUAL sEWAGE DISPOSAL SYSTEM --PERMIT ENVIRONMENTAL H'.ALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) **k��+A'*,k�•k'k'k'www,ttr,rkYX'+c,r}tttt*,t,tictk7ktl'+*,ki4*ic*dr*9[,tJr,th,kdt+kw**ir+-kF*,k*+,t�'+�++ir*F**dc * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 t * * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: L n MAILING ,ADDRESS APPLICANT/CONTAC LICENSED SYSTEMS T PERSON: COMPANY/DEA: ZzH-IAI' PERMIT APPLICATION IS FOR: (� PHONE PHONE 3g7v ADDRESS: 11Q 1 4y wx L_h NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Descripr-ion : Tax Parcel Number: Physical Address: BUILD IF" TYPE; (Check applicable Residential/Single Family ( ) Residential/Multi-Family* { ) Commercial/industrial* category) TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well t ) Spring ( ) Surface ( Public Name of Supplier: Number Number Type -- of Bedrooms ` of *These systems requi design b a R gistered Pr_Gtessional Eng.zaeer SIGNATURE:: Date D 7� by AMOUNT PAID: �JRECEIPT #: DATE:__QjCHECK #: CASHIER: F*A 1 MbIL- Vlt C�J ' LKP + ngineening, Inc. CIVILICIE0TEG'iitwTlCA L May 28, 2002 Mir. Benno Scheideggeir Summit Habitats F.J. Box 1829 Edwards, CO 81632 Dear Benno: RE: Ynspectian Of Septic System installation Mickey Residence: Lot 5, Cordillera Filing No. 36 .(1�- JThe.. r' uiru`nit Trali Eagle County, Colorado Project No. 20162 -Permit No. 2034-00 Attne request of Arena. Excavating, on .Turn 12, Lvfrl, We visited the construction site for th Unckcey Residence, Lot 5, Cordillera Filing No. 36, 1016 The Summit Frail, Eagle County, Colorado. The purpose of our site visits was to inspect the installation of the septic system. They installed the system in overall compliance with the septic system- design, Drawing No. 20162SD.DW , dated Septieei'ryber 18, 2000. The system was installed as showm on the attached as-built.skeeteb. They msta[W- a 2ni,}n_gallort two'-- rin al-k1h n is rein• a to i L f 1^. s..,: Y.,� . �, p . W.;x„tz,b, p•.,ca. ooI# ,q sPrpitic to LIK and a I000-gsallon, cieeef c lift station. A cleanout was instalied between the house and the septic to k as shown on the attached u'rd—W—Mg- The, effiWent line was 4" diameter, sch 40 pvc; connected to the 311 diameter, central manifold. Six laterals were constructed, three on each side of the central manifold. The laterals were a 1-1/4" diameter, perforated at their inverts witli 114" holes at 48" intervals. The ends of the laterals were capped. The gravel absorption area was 81 feet by 14 feet. The mound perimeter consisted of mortar type sand. with an tip slope dimension of 15 feet, 25 feet on each side of the gravel bed and 50 feet below. Inspection ;ports were installed on loth aides of the gravel heel. The. nUmp was installed and tested and a letter~ (attached) was submitted to us by Ball Schierkolk with Castle Peale Plumbing, Inc. if you have rdly l—stiouLs, please do not heiit'w' z tv ;.uii. Sincerely, Al 4� `'ti, �a l�C'? 29 a e Luiza Fetrovsk�` er Wt President cc: Ms. Laura. Fawcett, Eagle County Environmental Health Division, fax: 328-0349 tl,\Doeummts and Seifiitg dTninisirator\W DocumeriU\iWP!fi-i.KPt21)1620$1-moupa.wpd '.O. Box 2837, Edwards, CO 81632, (970) 926-9088 Tel, (970) 926-9089 Fax M^ki.. ',r,._'ni_ n i.ii-f 4 Ti-i Czx_i C V -f ii ii i-1 V ii it l Ui=nl Tf-f pGt'�:'- 1 Si I-% T3..... 1%0'7+-7 � f.......A.. r4r ®1 r— /^a ^% nnr nnnn — i n�rn� —, . c-u- Javx A03 r, nuwaruti, Lev 0AVJL, (7/V) 5FLO-yVi5o Iel, (Y(V) 924-9089 Fax MCW_!7,q_�XnfAXLitiri ii-i-3=fXi 1= fi-ttWiiV PW i i4Pr4i Ti-i PAGP:r • "—''- �YV 1 F-IIIL VJf UJ rla ce u� U'�3 4 is �41�l11t13 Habitats C9701 826-4696 CASTLE P y. PLUMBING INC. To Wixom it may concern, AS firer l..l;.F E91i WOW ris gring Inc, Civil drawing , titled S t e System l Win, dated l- 0--Wd pimp WE0712 PX 230 volt/ l ply l- S10020 , Mlq x .}f+:r+aiiali ^fC> rt I pzafie1wial a Tf, Palz been i ci llafi �trnf# ; vtp�. Wf F .. Dutton ai lot 5 Cardtllera Film' # 36 'rMi l pragle ca"'ty CO. The cotztr l pawl is located in s c►nWlvbm at thels.>Wer jewX $Qutb east corm of building. Bill Schw4 rkolk r mottle Peak Ph2nbing frx. 051241t}7 MCaY-:P+=a-Pf-Af i;n 1APFt 1 M - drAnM TF1- Frar�l f= r 'i d IMTV PHI J I4PaI TI-I Gtar = : 7 ISDS Permit #D�"U �� Date I 13101 ISDS Final Inspection L 10006 d10 d, Tank is .1000 gal. Tank Material Qom" it `! Tank is located 3`f 6 ft . and /' 1 degrees from 1pvnr en0 lrkl Tank is located ft. and degrees from (r.sa.aac laaas.rlc) Tank set level. Tank lids within 6" of finished grade. Size of field ft2 units lineal ft. Technology g (lX 144 .` J'1 OU40e - Cleanout is installed in between tank and house(+ 1/100ft). There is a "T" that goes down 14 inches in the inlet and outlet of the tank: Inlet. and outlet is sealed with tar,,tape,_ rubber gasket etc. '� k has two =compartments with the.;f3.air er•,cpt 1paxtment closest to house. �rw : M+ea_eure: distance and relative direq©n to:, field; Aepth of field. ft. Soil interface raked. Inspection portals at the.end of each trench.. Proper distance to setbacks. IJ=� Chambers properly installed as per manufacturers specifications. (Chambers latched, end plates properly installed, rocks 'removed from trenches, etc.) Sc�a Type of pipe used for building sewer leach field 3' Other Inspection meets re=irements. Copy form to installers file if recommendations for improvement were suggested. ACTION TAKEN: Setbacks Well Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Field 100 25 20 10 50 25 10 10 Tank 50 10 5 10 50 10 * 10 2034-00 Tax #2107-162-05-UUZ JOB NAME Lot #5, Filing 36 ULICKEY Cordillera Subdivision S166 summit Trail, Edwards JOB NO. 1) P- 1-33L? JOB FOLDER Product 278 JOB FOLDER bj 13 101 cK -a 2L34-0 0 Ltkcv-ej, 2034-00 Tax #2107-162-05—OUL JOB NAME Lot #5, Filing 36 ULICKEY Cordillera Subdivision 9166 Summit Trail, Edwards JOB NO. 1�3�s9 U JOB FOLDER Product ZM JOB FOLDER VJa-S SRDLL Siabt�'Sp "� ;hu�ickU e SoS � �a aPkeE�°��telcA. ti mo:u F A DESIGWCALCULAWNS OR GROSS - NET DISCHARGE. *EIGHT vixjw PV? 01ME' TANK 1050 CAL �,900 GAL Variable 4752 galona 93W Las - per verticaf inch -A -------------------- ZZ DIAUVEP -09 TION��A L uROSS A-7 I..:, c -48--;-20001 PUMP IWOM A41r c3l