No preview available
HomeMy WebLinkAbout201 Eagle Crest - 210518202004INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT Eagle County Department of Environmental Health PERMIT N® 0766P.O. Box 850 - 550 Broadway Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST PLEASE CALL FOR FINAL INSPECTION BEFORE BE POSTED AT INSTALLATION SITE COVERING ANY PORTION OF INSTALLED SYSTEM Owner: John Boles Address: P.O. Box 71 - Edwards, CO 81632 System Location: Telephone: 926-3202 201 Eagle Crest Road - Lot 6 & 7, Block 6, Lake Creek Meadows Subdivision Licensed Installer: WY Construction License Number: . Conditional installation approval is hgry y r g$pd for the following: Lot 6 - 750gl Lot 7 - 1250gl Minimum requirements: Lt 7-12llon Septic Tank or Aerated Treatment unit Absorption area of dispersal area computed as follows: Percolation rate:__1Inch in 20 Minutes Absorption area per bedroom 280 Sq. Ft. Number of Bedrooms 5 X 280 Sq. Ft. minimum requirement per bedroom - equals 1400 Total Sq. Ft. minimum requirement Special Requirements: See Attached Letter Date: 09/22/86 Environmental Health Officer l y. Siz ao CONDITIONS: 1. All installations must comply with all requirements of the Eagle County Individual Sewage Disposal System Regulations, adopted pursuant to authority granted in 25-10-104, C.R.S. 1973, as amended. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structure not approved by the zoning and building departments shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Section III, 3.21 requires any person who constructs, alters or installs an Individual Sewage Disposal System to be licensed according to the regulations. FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Eagle County Individual Sewage Disposal System Regulations until the system is approved prior to covering any portion of the system. INSTALLED ABSORPTION OR DISPERSAL AREA SQ. FT. ` L LON INSTALLEDSEPTICTANK:L_ AS;y DEGREES;FEET DESIGN ENGINEER OF SYSTEM: INSTALLER OF SYSTEM: PHONE:. SEPTIC TANK CLEANOUT TO ITHIN 12"OF FINAL GRADE OR AERATED ACCESS PORTS ABOVE GRADE: YES v O PROPER MATERIALS AND ASSEMBLY: YES O COMPLIANCE WITH PERMIT REQUIREMENTS: YES COMPLIANCE WITH COUNTY //STTE REGULATION REQUIREMENTS: YES NO COMMENTS: 14 c ' 11671 Any item checked NO requires correction before final approval of system is.madee.. Arrange a e-inspection when work is completed.) DATE ( Final Approval)11 ENVIRONMENTAL HEALTH OFFICER: DATE ( Re -Inspection) ENVIRONMENTAL HEALTH OFFICER: RETAIN WITH RECEIPT RECORDS Name of Applicant: John Boles Amount Paid: $150.00 Receipt Number: 2390 Name of Owner: Same PERMIT Date: 2 86 Cashier: G. Parker White and Pink Copies - Environmental Health Department Yellow Copy - Applicant / Owner APbT ICA FOR-ui-i.-., AL SC..AGOIS-21SAL .C— ? T.., EN,' IRON`E:;TAL HEALTiI OFFICE - EAGLE CCU',TY P. O. lox S50 r- i Eagle, Colorado 81631 No. --.5ro PERMTT APPLICATT0% FEE: S150.00 328-7311 PERCOLITIO`d T!'ST F 7 $TJn' NA.` fE OF OWNER: 4oaN 4/Qje/S7jNL-- SOLZ ADDRESS: , 80X 7% &X>fc/1-24>S coi-U <y&'s Z PHONE: %ZC - 32 O L NAME OF APPLICVNT (if different from owner): ADDRESS: . e_ PHONE: DESIGN ENGINEER OF SYSTE.`1 (if applicable) ADDRESS: PLt JVII 1\J_01 lUuL : : INSLALL-MON OF SYSTEM: Licensed Installer (see attached list): ADDRESS: 1YaX /OOO ZA-C- -T PHONE: YES NO PERMIT APPLICATION IS FOR: 0e) New Installation LOCATION' OF PROPOSED INDIVIDUAL SE?•:AGE DISPOSAL SYSTEM: Street/ Rural Address: _-20/ C/4-CLL c2&-ST k Lot Size: i2t I 4 j, 8 Legal Description: 4r--T G, *- 7 13/%C Le BUILMI G OR SFRVTC'F TYPE —14-'I'l : — ---- Residential - Single Family Residential - Duplex Residential - Tr_plex NUMBER OF PERSONS: WASTE TYPES (check applicable cate^pries): Commercial or Institutional Non - Domestic Wastes O Garbage Disposal fir) Automatic Washer Other O- OF INDIVIDUAL SELAGE DISPOSAL SYSTEM PROPOSED: PHONE: 9Z 7 - 3 431 Alteration Repair Residential - Quadplex Co.•--:: ercial (state usage) NUMBER OF BEDR00_•iS : 0 T" (P - / Lv7' 7- el Dwelling Transient Use ic) Dishwasher Y-) Spa Tub X) Septic Tank (Z) ( ) Composting Toilet ( ) Incineration Toilet Vault Privy ( ) Greywater ( ) Chemical Toilet Pit Privy ( ) Aeration Plant Recycling, Potable Use Other Recycling, Other Use s WILL EFFLUENT BE DISCHARGED DIRECTLY INTO ?'AT='RS OF THE STATE: YES ( ) NO () IS SYSTEM DESIGNED FOR LESS THAN 2.000 GALLO?:S PER DAB'• YES (x) NO ( ) WASTEWATER FLOW REDUCTION PLAN: YES ( ) NO (,) I S yes, see attached was.t emte.t Stew ,Ledci ti_c;1 Med ods ) NOTE: The EnvZ%o;une;7.ta2 Heae_th O''.i.ecrL mail .educe the •,Leoui..ed ab.s0rLptio;i atea upon app, tovuZ 05 a;i adequate a:as -urati2 1, 5 ccv .teduCtCOII pZa,7. SOURCE AND TYPE OF WATER SUPPLY: ( ) Well Spring (!') Creek/Stream Give depth of all wells within 200 feet of system: itice>h/ If supplied -by communi water, give name of supplier: LAKE c42-MO, 4,44-Te2 Pti- SIGNATURE: - DATE:_ e — — — — — — — — — — — — — — — — — — — — — — — — — — -- s!— INFORMATION dEE LIWTO BE FILLED OUT BY ENVIRONMENTAL HEALTH OFFICER: GROUND CONDITIONS: Peneeist G,tound S.Zope r Depth to Bedto ch ( pen 8' P.to S'ZftHot e ) Depth to Gnou;idtcate,`c Tab& SOIL PERCOLATION TEST RESULTS:. M.i;iutcs pet .bLc;t -cn HO.Ze nI ao vnrS - .,sz pe'2 # 5-0,z Minutes pets inch .to Hole #2 FINAL DISPOSAL BY: Abso. tptio;l Ttte;ich, Bed o-t Pit ( ) Evapo.ttansPiAatc:on Above Gncund DZSpe.,sa2 ( ) Said Fi-P-tet Unde, tg.tound Dispetsae ( ) Was.Lcwatct Pond Amou; tt Pac d: Recei,ot Nu;ibc.t NOTE: Site Plan must be attached to -application. Date.: Env. Health Department - Rev. 4-07-83) PERCOLATION TEST ENVIRONMENTAL HEALTH DEPARTMENT Eagle County FEE: $50.00 ISDS APPLICATION NO. 26,;'0 OWNER: LEGAL DESCRIPTION: Lj->-r 6-r 7- RURAL ADDRESS: TYPE OF DWELLING: DATE OF PERCOLATION TEST: //- ?- -7 9 TEST HOLES PRE-SOAKED: YES NUMBER OF BEDROOMS: CJ Lo-r (0- / Lui 7— NO TYPE OF SOIL: TIME WATER DEPTH INCHES OF FALL RATE 1 2 3 1 2 3 1 2 3 1 2 3 PERCOLATION RATE: a o P) A RECOMMENDED MINIMUM SEPTIC TANK SIZE: (.csT 4, _ '`/S® 61 I, RECOMMENDED MINIMUM LEACH FIELD SIZE: / V60 /( RECOMMENDED MINIMUM SQUARE FOOTAGE PER BEDROOM: 986 qOo f( SITE HAS BEEN REVIEWED AND TESTED FOR PERCOLATION RATE. ice mac .--, 1 i - - Environmental Heal l Officer Date COMMENTS: .. c? Oti G/ `I.* / e Rev. 5/31/84 L EAGLE COUNTY 551 Broadway Eagle, Colorado 81631 303) 328 7311 CERTIFIED MAIL NUMBER - P 661 276 901 September 22, 1986 John Boles P.O. Box 71 Edwards, Colorado 81632 RE: Lot 6 & 7, Block 6, Lake Creek Meadows Dear Mr. Boles: Your individual sewage disposal system permit for the above referenced property is enclosed. You should attach this letter to your permit and consider the stipulation stated herein as condition of the permit. CONDITIONS FOR PERMIT #766: 1. The applicant must submit an as -built site plan showing the exact location of the sewage disposal system and an alternative or backup leach field site. The site plan must be prepared and signed by a registered enc ink, r architect or surveyor. 2. A lea h field easement -Just be created on Lot 6 for the co on disposal o !sewage effluent from Lot 6 & 7. In ad i ' , each field maintenance agreement must be approved by this office and recorded with the above referenced leach field easement. The leach field easement and associated maintenance agreement must be approved and recorded prior to issuance of a certificate of occupancy for either lot. Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer P.O. Box 850 P.O. Box 449 P.O. Box 537 P.O. Box 359 P.O. Box 479 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 John Boles September 22, 1986 Page 2 3. This permit is approved based on the building plans drawn by Snowden and Hopkins Architects - Job #8601, dated 9-4-86. A new individual sewage disposal system permit shall be required for expanded use beyond the designed capacity as stated in ISDS Application #3070 and the above referenced plans. 4. Water conserving appliances and fixtures are highly recommended. If you have any questions regarding this permit, please contact me. Sincerely, Sid Fox Asst. Environmental Health Officer EAGLE COUNTY SF/gp Enc. cc: ---Building Permit File C , Oc j ccr- v `l i r U 1 F, Sip . `• 1 2 EXHIBIT A PAGE I OF 2 QcT y? 3 07 PM'Bi LOT 6 1 1 21°13'54" R. 232.51' oo Y ' A. = 86.16' C.D. = 85.67' 5.00037'54"W. s° ? 3 3 , tiA b oh jYV ti° ry p ° h p BLOCK 6 `'s °2 ti do1P.0.8. c LOT 7 y, F- 0 . N W s N W W J LD 4 W SCALE I"= 40' t 1 4.iclCc>wri SEirvc.'ing Lri;inecril g, luc, OHrd i_M oATE a SEPT 87 P. O• Box 323 • 109 Brooks Lane Eagle, Colo. 81631 (303) 328-7208 87,005 COST 'SHARING AGREEMENT,.. For Maidtaince:of Co'mmon.Sewer,System `Serving DweTli`ngs on Lot 6 and 7, Block 6, Lake Creek Meadows, Eagle Co. Colo. As purchaser of: Lot ,, Block 6, Lake _Creek Meadows, in ' Eagle Co. Colo. I.agree as follow; I`-sha11 pay on demand the share of the cost of maintaince', repair and replacement of the sewer system, ie. sewer pipe and leach field, such share being one-fourth to Lot 6 and three -fourths to Lot 7. 2:; The above stated share is based on an: approximate one- fourth/three-fourths square footage relationship between- the two dwellings. 3. I agree that if I sell my share, I shall advise the buyer of this agreement and that the signing of this agreement is.a prerequisite to.the >sale 'of said share. 4... This agreement may be modified, changed, deleted from, or added to, onl'y,with the mutual consent and agreement of the owners ..and.., the noti£f icaLion of. - the Environmental Health .Office.,; Eagle Co., Colo. Dated;.; Signed, Owner) Purchaser) i 1987 t Mr. John D. Boles Post Office Box 2088 Vail, Colorado 81658 RE: Lot(s) 6 & 7, Block 6, Lake Creek Meadows Subdivision Dear Mr. Boles, Thank you for pointing out the discrepancy with the conditions of.the "footing and foundation permit" and the individual sewage disposal system permit". _Upon recon- sideration of the conditions, it has been determined that the leach `field easement and associated maintenance agree- ment must be submitted for review with your building permit application. The leach field easement and.maintenance agreement must be recorded with the Eagle County Clerk and Recorder prior to final inspection of the individual sewage disposal system. The other conditions referenced in my letter to you dated September 22, 1986, remain in effect. I hope this discrepancy did not cause you delay or hardship If you have any questions concerning this matter, please call or write. Sincerely, Sid Fox, Assistant Environmental Health Officer EAGLE COUNTY 551 Broadway Eagle, Colorado 81631 303) 328 7311 February 19, SF/cb cc: Bldg. file ISDS file Chrono file Board of County Commissioners Assessor P.O. Box 850 P.O. Box 449 Eagle, Colorado 81631 Eagle, Colorado 81631 Clerk and Recorder P.O. Box 537 Eagle, Colorado 81631 r o eta` 00 0 V tifi Mr. Sid Fox Environmental Health Office Eagle, Colorado 81631 Dear Sid, September 13,1986 Enclosed is an application for the sewage disposal system for my residence in Lake Creek and a check for 150.00 dollars for the fee. As we discussed I am not sending a check for the percolation test fee at this time because one should be on file in your office from 1981. If you have any questions or run into any more problems in processing my application please call me at any time. Sincerely, l John D. Boles P.O. Box 2088 9 Vail, Colorado 81658 .926-3202 .476-5810 INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. REPAIR PERMIT NO. 1873-99R ORIGINAL NO. IS-0766 OWNER: JOHN BOLES PHONE: 970-926-3589 MAILING ADDRESS: P.O. BOX 717 EDWARDS, CO 81632 APPLICANT: SAME PHONE: SYSTEM LOCATION: 201 EAGLE CREST RD., EDWARDS TAX PARCEL NO. 2105-182-02-004 LICENSED INSTALLER: DOUBLE M CONSTRUCTION. LARRY MORGAN LICENSE NO. 25-99 PHONE: 970-524-7429 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: EXISTING 1250 AND 1000 GALLON SEPTIC TANKS 2250 SQUARE FEET OF ABSORPTION AREA VIA 73 INFILTRATOR UNITS AS PER DESIGN. SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED5/11/99. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. PLEASE SUBMIT AS-BUILTS AFTER CONSTRUCTION IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL: ATE: MAY 20, 1999 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE FAGZCO_UNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 2 2 5f1 SQUARE FEET (VIA 73 TNFTLTRATOR UNITS ) EXISTING TANK: GALLONS IS LOCATED DEGREES AND FEET FROM COMMENTS: ENGINEER'S AS —BUILT DRAWING RECEIVED 7-6-99 ADDTTTONAT 500 GAT.T0N TTFT STATTON WAS INSTALLED TO ACCOMMODATE THE LOWER ELEVATION OF THE PIPE RUN FROM THE TANK TO THE LEACH FIELD ALSO AN ADDTIONAL CLEANOUT WAS INSTALLED ON THE SOUTH SIDE OF THE DRTVFWAv, ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL V ' DATE: JULY 8, 1999 iete Applications Will Si'e Plan MUST be attached) NOT Be Accepted ISDS Permit ## Building Permit T APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMITENVIRONMENTALHEALTHOFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 e rrrrrrrrr:r:rxr7rrr rr:r r7rr:r 8 8rr:r/9r*rr823vry( Basalt) rrvr:irr r crrrr rr:e*rvrPERMITAPPLICATIONFEE $150.00 PERCOLATION TEST FEE $125.00 MAKE ALL REMITTANCE PAYABLE TO: " r rrrrcvcryrxrrr rxtrrr c rrrr r r crr rrr*rvcr crrrr cEA r COUNTY r R AS RER"rr c5r rrr x PROPERTY OWNER: MAILING ADDRESS: ?O • per 717 r-t E>S CO $/C32 PHONE: APPLICANT/ CONTACT PERSON: b + N QoC PHONE.: LICENSED SYSTEMS CONTRACTOR: LA} D_y ,q PHONE; 52,f •7 lZS COMPANY/ DBA:UgIC- M C C,A} t DDRESS: cu M PERMIT APPLICATION IS FOR: (k) NEW INSTALLATION LOCATIONOFPROPOSEDINDIVIDUALSEWAGEDISPOSALSYSTEM:Legal Description: Lam- E u. "e paws Tax Parcel Number: Z Io51 SZO 4 Lot Size: Physical Address: Zp i L A-yL.j:-_ /^ -C BUILDING TYPE: (Check applicable category) Residential/Single Family Residential/ Multi-Family* Number of Bedrooms y Number of Bedrooms Commercial/Industrial* Type TYPE OF WATER SUPPLY: (Check applicable category) C) Well ( ) Spring ( ) Surface PublicNameofSupplier: These systems require design by a Registered Professional En gineer SIGNATURE: r Date: itYC*Yc*Y[YC NC Y: 7r iC Yc t XY[ic*Yc rr Yl Yr*ic it 7k :c Yc t Y**)k Y[r*7l Yt yt Y:* **lr Yc**:fc 7K Yc*YC AMOUNT PAID: 0 RECEIPT Y : (( DATE: CHECK z: CASHIER: TIME LOG: TRAVEL: PERC: FINAL: Community Development Department 970) 328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com EAGLE COUNTY, COLORADO July 8, 1999 Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 John Boles P.O. Box 717 Edwards, CO 81632 RE: Final of ISDS Repair Permit #1873-99R; Tax Parcel #2105-182-02-004. Property, location: 201 Eagle Crest Rd., Edwards, CO. Dear Mr. Boles: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL:Informational Brochure Final ISDS Permit cc: files INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 ORIGINAL PERMIT #1873-99 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. ALTERATION PERMIT NO. 1988-OOA BP NO. 12939 OWNER: JOHN BOLES PHONE: 970-926-3202 MAILING ADDRESS: P.O. BOX 426, EDWARDS, CO 81632 APPLICANT: SAME PHONE: 970-926-3202 SYSTEM LOCATION: 225 EAGLE CREST DRIVE, EDWARDS, CO TAX PARCEL NO: 2105-182-02-004 LICENSED INSTALLER: SNIDOW BACKHOE SERVICE, DONNIE SNIDOW LICENSE NO. 51-00 PHONE: 970-260-3478 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 5 BEDROOM RESIDENCE 2000 GALLON SEPTIC TANK TO REPLACE THE TWO EXISTING TANKS SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 5/24/00. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. ENVIRONMENTAL HEALTH APPROVAL: & L_ _4U4 DATE: JUNE 5, 2000 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET (VIA ) INSTALLED concrete TANK: 2000GALLONS IS LOCATED DEGREES AND FEET INCHES FROM see as -built drawing for system component locations. COMMENTS: Engineer final certification and as -built drawing received June 12, 2000, This system is large enough to accommodate 5 total bedrooms. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL( i f.(f DATE: '-®O-D NOT Be AcceptedincompleteApplicationsWill Site Plan MUST be attached) PfeuICUs Agem «-.v- i a-7 5 - 91 ISDS Permit # Ci Building Permit 7 2Q 3 APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (Basalt) PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $125.00 MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: ZdLF-S MAILING ADDRESS: _ it x-J2,, Epw 42z5 co g I (=3Z PHONE: `tZr- -5zo z APPLICANT/CONTACT PERSON: JON*-3 30LG5 PHONE: TZ(,-32o2 LICENSED SYSTEMS CONTRACTOR: too r- 5 N Dew PHONE: R7o-Z(op-'`f78 COMPANY/DBA: 6wDr)W ADDRESS: PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION ( ) ALTERATION (x) REPAIRLOCATIONOFPROPOSEDINDIVIDUALSEWAGEDISPOSALSYSTEM: Legal Description: ITS &1-7 tat,-K 6 L,,Atee c +c wtEr4lpwS Tax Parcel Number: c+_ Lot Size: l• F3 prc— Physical Address: 2.0It225, BUILDING TYPE: (Check applicable category) Residential/Single Family Number of Bedrooms $ Residential/Multi-Family* Number of BedroomsCommercial/Industrial* Type TYPE OF WATER SUPPLY: (Check applicable category) Well ( ) Spring ( ) Surface xj Public Name of Supplier: LA E C_eCe5-rc yKrI-ep o STeicr These systems require design by a Registered Professional Engineer SIGNATURE: ] a% Datec k*****k*Ycxx x,xa yr rcr 7cx**Yr**rc*x Yr vc*vrx Yc*vr****vc**vrx*xyc Klr Yr**xyc yc* J'/30 /0 AMOUNT PAID: RECEIPT Y : I ' DATE: CHECK: CASHIER: TIME LOG: TRAVEL: PERC: FINAL: Community Development Department 970)328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com June 12, 2000 Mr. and Mrs. John Boles P. O. Box 426 Edwards, CO 81632 EAGLE COUNTY, COLORADO Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Final of ISDS Alteration Permit #1988-OOA, Tax Parcel #2105-182-02-004. Property location: 225 Eagle Crest Dr., Edwards, CO. Dear Mr. and Mrs. Boles, This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Laura Fawcett, REHS Environmental Health Specialist II Eagle County Environmental Health ENCL: Informational Brochure Final ISDS Permit cc: files Community Development Department 970) 328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com Date: June 5, 2000 EAGLE COUNTY, COLORADO TO: Snidow Backhoe Service Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Alteration Permit No.1988A-00. Tax Parcel # 2105-182-02-004; Property Location: 225 Eagle Crest Drive, Edwards, CO., Boles residence. Enclosed is your ISDS Alteration Permit No. 1988A-00. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files LKP Engineering, Luiza Petrovska 05/24/2000 11:04 970-926-9089 LKP ENGINEERING, INC PAGE 02 LKP Engines CP JGE }' May 24, 2000 _ Mir: John Boles RE: Mo tic System P.O. Box 426 Lots 6 & 7;"eic a Cr®ek Meadows z Edwards, CO 81632 201.& 225'ie'C.Drive: Eagle Co f .=;£qlo: Project Nu > it-Nik 1873-99 Dear John: At the request of Qui$ti slg of.. Boles Cust 3tu Inc , on May. 22, 2000, we visited the site on Lots 6 & .1 .sake Creek M " :? 't 2SEagle Crest Drive Eagle County, Colorado. Thelarour site: visits'''o 44&ve dieuncovered septictank for the main residence and prendations foitwon. The leachfeld and a :5 `g electric lift stag we nstiue din May of 1999. Based on the on -site conyT21.:' ' t, we unde Ci ; .' :ot refer to have one septic tank for both buildings. Sini` Held was des.. d `tiruuc a to serve both p buildings, we also, thought if,radical to ha stank: We have confirmed this r with theEagle. County 'Envi:;ealth. Departm Included with this l Mr.' ae= .,4 ign'and the lion €or the new septic tank. r •_32 Thedrawingsshouldbesubaed. Eagle County, th.pai`tmeiit:for.a repair permit. If you have any quesle, -p do not hesitatelh- Sincerely, LKP Enginee} Luiza Petrov1j'E aZz President Enclosure Myf iitc\ corcldoc\ WPDOCS19983mo16VD f•. — ;may" P. O. Box 2837, Edwards,lY;(970). 926-9088 `Y (9'1#' 9$ 9:ax, E-mail: Ikpeag@snowcap.net 05/24/2000 11:04 970-926-9089 LKP ENGINEERING, INC PAGE 03 kPTI(" SYSTEM MODh'ATL01. the existing septic toi* for the four ::4idroor .residence at 225 Eagle Crest Drive wcs•::exco'vaf-ed. to .investloke odor . it was found that the inlet cornnection".fram ;$-e..building. seiner lini `& the septic tank was bent. It was also. obssl'ved that the iPOsting ;rank' was made out of plastic. Since the leocifield for the 4 bedroom residence is combined with the leochf4kf: for the one bedroidA"1• restc nce at 201 Eagle Crest Drive, the proped• 2{'0-gallon, . corgi, ;t'.fe `septic tank will serve both residences. The •old- s p_lic tank .at 'the 4-6e&bom residence will be Pumped out firil. on,4" han filled wtth+ .'fond, so it can be . abandoned; The existing septic. forvk .for .the one! ocif 3 residence will be pumped vut and removed Als.0j, new. building.=_sewer -At will.be constructed from the 4-bedroom .esdce :to' !he ne•-=twnk The new building sewer line . will bypass the•'bid tthe old buileft seam line, '.ond the old. delivery line. Ne ..c}.eakouts will be atrudtibd in front of both. buildings, and ot- 106- 4 ,6ot intervals ; 'ong -the sewer line, as necessary.. ICES/GN CAL C414A 011r, •jz•. Number of bedr m. s _: 4 in the mo `+hour' and one in. the second house Moximum daily Qm.dx 5 'bdr s x 2='persons/bdrm 5 ollons/person/day x 1509. CJm ox 1125 _Op d " SEP TICTANK `-'_{` V 0m ax/24ttr$ . x- ,3 J" hrs _ V = 7406 gollot's . Use 2000 gallon.;: two.. compartmen t pasmt.... oncrete tank by Copland Cofi&wfe ;b' equivalent NO TES: l: The building; a: 110he from the 'use :x•=the Sep tic took sh`alf: have slope. of 1/. tii;ch.p 'r foot. Bends in the building ge shall be 4 te4 45 degrees. 2. the septic...tonk stabll be instq/level.;;<le tank sh all h a've . rem'o wable .CEO vers or m onl ,O*. -- inches 'of . the fidtished igrade, for in'seo flan tr/ cleaning. _ 3 All installotr,6h-i§ •BE I meet the r r s and regulations of . 4; Eag - County Envirar ir en ca:;Hea/th Division, Chopte 4, lividual . Sewog'Aisp i5tl Systems. 4. The Sep tic Sjr ferb:'.,; nstallotion sh'a .be Nib ected by the Design . Engrteer' Dior to bockfillin; SEP ` d % F'ICATION PRO ECT NO.: 998 3 f CIVIL% GS0 4 Eif:1S COTS: LAKE CREEK MEADOWS SCAtE . b1 'Pis EAGLE ORES! ROAD N T. S. I I EAGLE •COUNTY, COLORADO qn re I FF' Englnee,ing; nc. os-za-zoov PREPARED FOR: -- ORAWINC NO.: .. . r.o. Box zes7 , dMards, vo`,63z . ;,•;flliN BOLES lcl (970) 926-90Ei6...+-Q t8-9089 _ - 05/24/2000 11:04 970-926-9089 LKP ENGINEERING, INC 'PAGE 04 ar o z Q. s: l U)` 13 4 -\ a W Z. Co. , l Wm o Y. a ,, az WI'` t mn p qvi xf ice_ , , • a 4 A"., . ROXCT Wa 9983" L< sEiiiAr. n rCATION C[V1L/Gl EFilliC i`• LOTS 'i' CAKE CREEK MEADOWS SCALE`;.. j'..' _ 40' 20J ' - E CREST ROAD " j 1 —EACCE COUNTY, Cot Do. DATE.- . KI Engin a ering, n c. os 24-2000. PREPARED FOR: ORAn,NC NO.: P.o. Sox 2837 Siiwardw,;l: .a1631 ] Oji%'is z tel (970) 926-90M LKP Enginee CIVELABO June 12, 2000 Mr. John Boles P,O. Box 426 Edwards, CO 81632 Dear John: Lots 6 4, reek Meadows 201 it 2.2 A-1 Dnw Eagle C.**, rMliNo. 1988A-00 0AttherequestofQ4AWW4-1 *A,S 2000, we vb N Block 6, Lake Creek -225 Eagle 6 the insWlafiol purposeofoursitevisitsWa*., 11. T.. concrete Theyinstalled, 0 sq line from the main residence"I Also, the 201 Eagle Crest Drive to 'NOw clegmouts the secondary residence. Alidi: -was installed the new tank. Risers will be' E' bring the ame4l inches from the finishedAn as -built of gr1yL . do not hesita If youhaveanySincerely, LKP Engineeriz Luiza Petrovska., President Ms. Laura Fawcett; :WF1-,,.-.`.C1'. ly Environtnm. L, A M y Fft\v) reW o OWPOOC SMS r&;I( 970 F.Q. Box 2837, Ed,wai ) VWfi6n, site on Lots 6 & 7, ae C. *='ty, Colorado. The• sysii rn alteration., tA ow inch diametersewer f . 9066ndw residence at at-.tfiv::main tesidence and at ex a1 9, 40 feet south from 31-illi. s pdc tank within 8 i6n is'Oppended to this letter. 6t-fax: 328- 7185 901 MOWN 4 WV. 1 g E-mail-, UTOnS@SnOWr- ajP,net v s-,r .ter cer sew u r .:u J u—Teo-7U07 LY r CIVU11tiGtt'ClIYUf 1141, t'f Ut fJL V Q ce J ca d IL l\ i IL Et o Y I wy yyy M1, .4M 1 t L ul Lli IT UT 4y i` 1-Z z....... w PI C OWW"A PIOINN e GiV1G%011 -nd ML kt,•;7, S. LAKE' MEK hdEAAtJNS 3CAL£; — 7 ,. + 4Gr I t31 & i'"'AGL£ CREST' ROAD LKII i Engineering,Inc. EAGLE COATY. CotORADO onT; Ob- 12-•.9000 P 0. Sax 2837 f4 wardw' 90.4102 +ES pRAtux Hd.: 9ram tel (970} 9' ! • —9089y: WIN 3a''' 9Wiffs: .. ... .. iri1 F€:i=±?M14s¢i 4i:'... ra u7uii7 rtli7aar iivL. t'liUt ql f LKP , Engin + x ' July 2, 1999 Mr. John Boles RE: Ilnspec of is Systim Installation P.O. Box 1279 Lots 6 & 7, flock 6* Lake Creek Meadows Avon, CO 91620 201 & 225 ale Crest Drive Eagle Coun+tr.,:+Coloredo Project No: "93 - f r.raft No.1873-99 Dear John: At the request of Billy Morgari of Double M Co ruction on June 25 through the 29, 1999, we visited the construction site on Lots 6 & 7, Block 6, Fake Greek Meadows, 201 & 225 Eagle Crest Drive, Eagle County, Coiarado. The purpose.of our site visits was to observe the installation of the septic system. They installed the systerh in overall compliance *ith the septic system design, Drawing No. 9983SD.DWf i, dated May 11,1999. The system was.insWed, as shown on the as -built sketch, attached. During constmaction it was discovered that the outlet pipe from the existing septic tanks was lower than the.inlet to -the new leachfield. For d is reason a new, 500-gallon, lift stationwas installed. A new clamout was also, installed; ii. the south side of the driveway. . sriygn - xee, Standard. Infiltrator Chambers were installed as shown on the sketch. The infiltrators were connected with serial..tIistribution. In t&-last infiltrator of each trench, inspection ports were installed. Horizontal. distaff from center to -renter of the trenches, was 9 feet or more. All piping was SDR-35, 4-inch`PVC. .The depth of the trenches Was two to.three feet. The soil profile in the trenches was consistent With the soil logged'in the profile hole. An as -built sketch of the system, prepared by tht -installer, is included. The site over the leacbfield should be graded to divert all runoff away from the leach£.eld. Water from an irrigation system or roof runoff can satin the leachfield and reduce its life. If you have any questions, please do not hesitate to call. Sincerely, LKP IEnR r President cc: Ms. Heather Savalox, Eagle County Environmenial Health Division, fax: 328-7185 Acoreldoe\ WF' 0CS199330S1.WPD P. O. Box 2837, Edwards, CO 81632, (970) 926-9088 Tel, (970) 926-9089 pax, E-mail: 1kpeng@snowcap.net i3' a rA J f V 7G0-7CJ07 LKr LNUINttKiNU, INN PAGE 02 h hh YY\•hhA h\V...... .. ............„\ 1 +\`l ......... Y+lh a+h allay\Y w mow 1...- _ _••_.. t J fft ff } CIVIL/GROTE4'i31sICAL LKP I Engineering; Inc. P.O. Box 2837 Edwards, CO 91632 ial (970) 926-9008 fax (970) 026-9059 n 46 a AS -BUILT SKETCH LOTS'6.& 7, BLOCK 6. LAKE CREEK MEADOWS 201 & 225 VOLE CREST ROAD EAGLE C"rr COLORADO PREPARED FOR: pia. JOH.N BOLES 998.3 07µ02-99 1 LKP ENGINEERING, INC. P.O. Box 2837 Edwards, CO 81632-2837 970) 926-9088 Fax (970) 926-9089 PERCOLATION TEST RESULTS Location: Lots 6 & 7, Block 6, Lake Creek Meadows Client: Mr. John Boles 201 & 225 Eagle Crest Drive P.O. Box 1279 Eagle County, Colorado Avon, CO 81620 Project No.: 9983 P-1 P-2 P-3 TIME/DEPTH 23" 23-8/16" 25-8/16" 10 5" 2-8/16" 5-8/16" 2-14/16" 10 6" 1" 22" add water 4-8/16" 16-8/16" 4-2/16" 1-4/16" 10 6-10/16" 10/16" 20-12/16" 16-4/16" 4-10/16" 8/16" 10 7-4/16" 10/16" 22-12/16"add water 5-8/16" 2" 5-2/16" 8/16" 10 7-14/16" 10/16" 20-4/16" 14-12/16" 5-8/16" 6/16" 10 8-6/16" 8/16" 22-4/16" 2" 5-14/16" 6/16" 10 8-14/16" 8/16" Dry 6-4/16" 6/16" PERC RATE 20 MIN/INCH 5 MIN/INCH---J 27 MIN/INCH AVG PERC 25 MINUTES PER INCH Average Percolation Hole Diameter: 8 Inches Holes Dug and Presoaked: May 4, 1999 Test Run: May 5, 1999 Ir 0766 13o les LA & $Q % RAI (V 1873-99R Tax# 2105-182-02-004 1988-OOA Tax 9FLlU-1zsL-UG-vv4 Lake Creek 201 Eagle Crest Rd Lot 6&7, Lake Creek BOLES Lots 6&7, Lake Creek BOLES "'%% nrigNAME, Lake 201 & 225 Eagle Crest Drive201EagleCrestRd.; .__ Lake Creek Meadows, Edwards Edwards T.i_ar.TwUbar i. BILL TO DATE STARTED DATE COMPLETED DATE BILLED S ( q 9 . - Ll P ,ce : cL H,t 1 cf-r.,. .•- fin N , Si IS5D shn 00o jf kmk-- 40'0- Z9so IJ N dA- 61,all s 7-u - P 9 en ok -a - C- iv-w o oyLik e.0-)-1 • i LaL c uj,Y-Ite- L JOB COST SUMMARY a TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR INSURANCE J C U + e , . -1- C C 4 t I. S F .. .'- c I SALES TAX v ' l `L, a l e MISC. COSTS L c L. C." 6 V l C(C' ' S v o Cf) 11 e J c? f c TOTAL JOB COST Z GROSS PROFIT LESS OVERHEAD COSTS OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 ®® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 Printed in U.SA JOB FOLDER w 120 glasses. 3. All materials, installation practices, setback requirements, etc. shall conform to Eagle County's Individual Sage Disposal System Regulations.. 4, Th,3 Engineer amid - Eagle Cosnty shall be notified wfien construction commences and kept abreast of the cons'ctior, Process so that sufficient inspection can be performed to as_ure conformance to these plans. 5. An 4' dce observation pit is to be dug, prior to Y_4 'Y C'iIfy depth to bedrock and vater able-.. f: Ems—= MacKown Sur-cving Engineerin„ Inc P. O. Bcx 323 Eti: c r tirC3.: 20 GRAPHIC SCALE 10 20 +0 IN FEET ) 1 inch = 20 ft SERIAL DISTRIBUTION SEE DETAIL A -A DECT10N PORT 4NDARD INFILTRATOR TYPICAL Perc No. 1 Perc No. 2 Perc No. 3 20 minutes per inch 5 minutes per inch 27 minutes pdr inch Average percolation rate recommended for design T = 25 minutes ;er inch. k f 80 i r j NOTE. 1. THE OLD LEACHF/ELD, WHICH HAD FAILED, IS LOCATED BELOW THE PROPOSED NEW LEACHF/ELD. IT CONSISTED OF FOUR, 70—FOOT SECT70NS OF SB2 PIPE. SINCE ITS ORIGINAL INSTALLATION, 8 TO 10 FEET OF FILL HAS BEEN PLACED ON TOP OF THE OLD LEACHF/ELD. THE FILL MATERIAL WAS TESTED FOR ` PERCOLA T70N AND THE TEST RESULTS ARE INCLUDED. THE NEW LEACHFIELD WILL BE SHALLOW.: THE DEPTH OF THE TRENCHES WILL NOT EXCEED 18 INCHES ` m US2. ALL ELEVA 770NS MUST BE FIELD VERIFIED. J. SITE PLAN DIG177ZED FROM AN OLD PLAN AND HAND SKETCH, PROVIDED BY MR. JOHN BOLES I; f f DESIGN CALCULATIONS ' Design percolation rate T = 25 minutes per inch Number of bedrooms = 5 I Maximum daily Flow = Qm ox Qmax = 5 bdrms x 2 persons/bdrm x 75 gallons/person/day x 1509 Qmax = 1125 god SEP77C TANK V = Qmax/24hrs x 30 hrs V = 1406gollons Use 1500 gallon, two comportment precast concrete tank by Copland Concrete or equivalent ABSORP77ON AREA I A = 0max/5 x r k A = 1125/5 x 25 = 1125 s. f. Amax = 1125 s. f. Based on Applicatio Rate: f A = 1125gpd/0.5 gpd/s. f. A = 2250 s. f. Standard Infiltrator Chamber System in a trench configuration with on 'allowed 50 percent reduction in the absorption area is recommended. F Acorrected = 1125s. f. Surfa7c,e_ area of one Infiltrator Chamber = 15.5- s. f. Use nfiltrator Chambers in five trenches with 15 Infiltrators in the Arst three "and 14 in the last two.. NQTES I i 1. The building sewer line from the house to the septic tank shall have a maximum slope of 114 inch per foot. Bends in the building sewer shall be limited to 45 degrees. 2. The two existing septic tanks should be pumped out. New connection from the junction of the two outlet pipes to the first infiltrator chamber should be installed. SOIL PROFILE J. Excavate three (3) feet wide trenches. The horizontal distance from sidewall to sidewall between the trenches shall be a minimum of six (6) feet. f PROFILE HOLE 4. The bottom and the sidewalls of the trenches shall be raked to eliminate ;smearing. 0.0 to 8.0 feet Fill, consisting of to soil and dark brown, 5. Assemble and install the Infiltrator Chambers in the trenches according to the manufacturers p recommendations. silty sand. 6. Backfill the sidewall area with native on—s/te soil for proper support. j 7. Backfill the trenches with a minimum of 12 inches of tamped soil cover. 8. Avoid vehicle traffic over the system. O IYjW Y00 L Qcp J 09 K` 1 Y O W ONV V LLJ ca N rWr^ v O v rr`• V " V r co oo 0 V vww Ld w W 00 04 U x o O 1 000 oPe'O R+Eire,, O• • PETRO F 9. All installations shall meet the rules and regulations of the Eagle County Environmental Health Division, • Chapter 4, Individual Sewage Disposal Systems. ems: 29526cc o d 10. The Septic System Installation shall be inspected by the Design Engineer prior to backt7lling. HAMBER DRAWN BY L.P. CHECKED BY L.P. PROJECT NO. 9983 12' - DATE.• 05-11-99 6.25' L/ A 1 A 1 L A A DRAWING NO.: 9983SD. D P N. T. S. STANDARD INFILTRATOR SHEET _ 1 of 1 Work Classification: AlterationPermit PO BOX 4737 EAGLE CO 81631- PO BOX 4737 EAGLE CO 81631- Address Owner Information Permit Status: Active Project Address 210518202004 Permit Type: OWTS Permit Permit NO. OWTS-9-12-8077 Expires: 1/17/2013 Issue Date: 9/19/2012 Parcel No. 000201 EAGLE CREST RD Suite: B EDWARDS AREA, CO Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: (970)382-3987 Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)926-9088LKP Engineering, Inc Contractor(s)Phone Primary ContractorLicense Number JAKOB SCHWAIGER (970)331-1209 Yes JOHN BOLES Permitted Construction / Details: This OWTS Permit for work on Lot 6 is associated with OWTS 8-12-7914 which is to install a separate OWTS to serve the adjacent Lot 7. Permission is granted to disconnect the effluent line from the 2,000 gallon tank, cap it and seal the entry. At the request of the owner, the effluent line that extends from Lot 7 on to Lot 6 is to remain in place after making sure the pipe is empty and capped on both ends. Contact LKP to provide details for sealing the entry portal and to inspect the capping and sealing project prior to covering the work in order to certify completion of the permit. Issued by: Environmental Health Department, Eagle County, CO September 20, 2012 Date Customer Copy Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED Work Classification: AlterationPermit PO BOX 4737 EAGLE CO 81631- PO BOX 4737 EAGLE CO 81631- Address Owner Information Permit Status: Active Project Address 210518202004 Permit Type: OWTS Permit Permit NO. OWTS-9-12-8077 Expires: 1/17/2013 Issue Date: 9/19/2012 Parcel No. 000201 EAGLE CREST RD Suite: B EDWARDS AREA, CO Private Wastewater System Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: (970)382-3987 Cell: Inspection For Inspections call: (970) 328-8755 Inspections: IVR PhoneEngineer(s) (970)926-9088LKP Engineering, Inc Contractor(s)Phone Primary ContractorLicense Number JAKOB SCHWAIGER (970)331-1209 Yes JOHN BOLES Permitted Construction / Details: This OWTS Permit for work on Lot 6 is associated with OWTS 8-12-7914 which is to install a separate OWTS to serve the adjacent Lot 7. Permission is granted to disconnect the effluent line from the 2,000 gallon tank, cap it and seal the entry. At the request of the owner, the effluent line that extends from Lot 7 on to Lot 6 is to remain in place after making sure the pipe is empty and capped on both ends. Contact LKP to provide details for sealing the entry portal and to inspect the capping and sealing project prior to covering the work in order to certify completion of the permit. Office Copy September 20, 2012 Issued by: Environmental Health Department, Eagle County, CO Date Ray Merry CONDITIONS: 1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED 3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.ea lecount .us goo EAGLE COUNTY P.O. Box 179 500 Broadway Eagle, CO 81631 www.eaglecounty.us PERMIT APPLICATION FOR ONSITE WASTEWATER TREATMENT SYSTEM OWTS PERMIT # BUILDING PERMIT # 3122 - 09.09.1986 INCOMPLETE APPLICATIONS WILL NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED) FEESCHEDULE APPLICATION FEE $800.00 MAJOR REPAIR FEE $800.00 MINOR REPAIR FEE 400.00 This fee includes the OWTS Permit, Site Evaluation (Percolation Test, or Soil Profile Observation) and Final Inspection. Additional fees may be charged if a re -inspection is necessary, or a pre -construction site visit or consultation is needed. The re -inspection fee is $135.00 Make all remittance payable to: Eagle County Treasurer. Property Owner: John D. Boles MailingAddress: Box 4737, Eagle, CO. 81631 Phone: 970.328.3987 email John.boleslohotmail.com Registered Professional Engineer: LKP Engineering, Inc. Phone: 970,926.9088 Applicant or Contact Person: Luiza Petrovska Phone: 970. 926.9088 Jakob 6ebu)Q+�er- Licensed Systems Contra tor: 32D &n-AfU0741D1 License# V& a2 Company / DBA: Phone: Mailing Address: ��� 7 email Permit Application is for: New Installation X Alteration Repair Location of Proposed Onsite Wastewater Treatment System: Legal Description: Lake Creek Meadows Subdivision, Block 6, Lot 6 a/os /&-a oa oo41 Tax Parcel Number: Lot Size: 1.8 acres Assessor's Link: www.eaelecountv.us/gatie/ ao1 Physical Address: 22�9- Eagle Crest Road, Edwards, CO. Building Type: X Residential / Single Family Number of Bedrooms: 4 Residential / Multi Family Number of Bedrooms: Commercial / Industrial* Type of Use: *These systems require design my a Registered Professional Engineer Type of Water Supply: If Public Name of Supplier: Private Well Spring Surface X Public Lake Creek Meadows Applicant Signature: John D. soles Office Use Only Amount Paid: Receipt #: Check #: a Ll Date: G�ts� ldfl a �6/�i ,q � 0-� S - OLD (1999) AS -BUILT SKETCH WITH 73 INFIL TRA TOR CHAMBERS z Q) ti m O J Q W ctz cn LV l V c) Q I I Qj Q NUQ: p0 o� q Lo J SEPTIC\` FLl1 I �.,. CLEAN❑UT W "' INSPE TED I W SEPTIC TANK LIDS SEPTICCLEAN❑UT \ I EXISTING 2000-GALLON TWO COMPARTMENT CONCRETE SEPTIC TANK LOCATED AND E-MAILED (8-7-12) BY EAGLE VALLEY SURVEYING (TYPICAL) DISCONNECT THE BUILDING SEWER LINE FROM LOT 7 LOT 7 PROPOSED NEW SEPTIC SYSTEM FOR LOT 7 AS -BUILT SKETCH PROJECT NO.: 9981 CIVIL/GEOTECHNICAL LOTS 6, BLOCK 6, LAKE CREEK MEADOWS SCALE. N. T. S. 201 EAGLE CREST ROAD nLKPEngin eering, In c. EAGLE COUNTY, COLORADO DATE 08-31-2012 PREPARED FOR: P.O. Box 2837 Edwards, CO 81632 DRAWING NO.: tel (970) 926-9088 MR. JOHN BOLES 1 October 2, 2012 Mr. John Boles P.O. Box 4737 Eagle, CO 81631 E-mail: john.boles1@hotmail.com RE: Inspection of Septic System Installation Lot 7, Block 6, Lake Creek Meadows 225 Eagle Crest Road Eagle County, Colorado Project No. : 12037- OWTS-8-12-7914 Dear John: At the request from Jake Schwaiger, on September 26 and 29, 2012, we visited the construction site at the Lot 7, Block 6, Lake Creek Meadows, 225 Eagle Crest Road, Eagle County, Colorado. The purpose of our site visits was to inspect the installation of the septic system. They installed the system in overall compliance with the septic system design, Drawing No. 12037SD.DWG, dated August 7, 2012, and as shown on the attached as-built sketch. They installed a 1500-gallon, two compartments, plastic septic tank by Roth MultiTanks. There was an existing cleanout between the septic tank and the building, and a second cleanout between the tank and the leachfield. The second cleanout was on the effluent line, and was about 9 feet east from the tank. Seventy-five, Q-4, Standard Infiltrator Chambers were installed in four trenches. There were twenty-five (17) infiltrators in the first trench. In the second and third trenches there were twenty-two infiltrators each, and in the last trench there were fourteen infiltrator chambers. There was a minimum of six feet separation between the trenches. In the first and last infiltrator of each trench, inspection ports were installed. The T’s in both compartments of the septic tank were at least 14-inches long. They also disconnected and capped both ends of the old building sewer line, thus separating the two septic systems. The old system will service Lot 6 and the new Lot 7. There is no other warranty either expressed or implied. If you have any questions, please do not hesitate to call. Sincerely, LKP Engineering, Inc. Luiza Petrovska, PE Enclosure cc: Eagle County Environmental Health Department, E-mail: Terri.Vroman@eaglecounty.us J:\_WP X4-LKP\_2012\12037OSIQ4.wpd P.O. Box 2837, Edwards, CO 81632 Tel (970) 926-9088