HomeMy WebLinkAbout1609 Colorow Rd - 210713102002INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION v P.O. Box 179 - 500 Broadway • Eagle, CO 81631 �' / Telephone: (970) 328-8755m nl� .k COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1914-99 BUILDING PERMIT NO. 12784 OWNER: JACK SNOW PHONE: 970-476-9228 MAILING ADDRESS: 1000 LIONS RIDGE LOOP #3D, Vail, CO 81657 APPLICANT: SAME PHONE: 970-476-9228 SYSTEM LOCATION: 1609 SQUAW CREEK RD., EDWARDS, CO TAX PARCEL NO. 2107-151-02-002 LICENSED INSTALLER: VANDERWALKER CONSTRUCTION, BOB VANDERWALKER LICENSE NO. 54-99 PHONE: 970-926-1465 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 4 BEDROOM RESIDENCE 1250 GALLON 2-COMPARTMENT SEPTIC TANK, (ENGINEER DESIGN RECOMMENDS A 1500 GALLON TANK) 1250 SQUARE FEET OF ABSORPTION AREA VIA 40 INFILTRATOR CHAMBERED UNITS. SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 9/13/99. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION DO NOT BACK -FILL UNTIL AFTER THE INSPECTION HAS BEEN COMPLETED. BUILDING TEMPORARY CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS RECEIVED (�FINAL �APPROVAL. ENVIRONMENTAL HEALTH APPROVAL: rYG{ {,'Gl �.iJ X DATE: July 17, 2000 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1240 SQUARE FEET (VIA 40 TNFTT,TRATnR TTNTTS PFR T)F$T(-,W INSTALLED CONCRFTE SF.PTTC TANK: 1500 GALLONS IS LOCATED DEGREES AND 1 _ FEET INCHES FROM THE SOUTHWEST CORNER OF THE WESTERN CORNER C)F THE RTTTT T)TNf COMMENTS: ENGTNEER FTNAT CRRTTFTr.AT10,NRECEjVgO OCTOBER 199 2QOn THIS SYSTEM TS TARC'F FNOTIG14 TO ACCOMMODATF. A FC)TTR RFTTRnC)m j1 E21pENCg ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFO E FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. I 0 ENVIRONMENTAL HEALTH APPROVAL DATE: OCTOBER 20, 2000 y� 1 AWL Vi Sent by:EN4IR@NMENTAL WEALTH Aug-24-89 07 :21&m frw+t 1280349*970476.9023 FnCoMplete 7Applicat 10nS Will NOT Be Accepted •� itS.Ll e Platt MUST re atta:hed: lSDS Pe.-M« L itAV%_ c q Building.- APPLICATION FOR INDIVIDUAL SZNAGE DISPOSAL SYSTEM PERMIT ENVIF.UN.M.E4TAL HEi+_LTE OFFITE - 7. O. BOX 179 E,A"LE, ^G 82-5-11 329-87"5•'927-3$23 (Ell .lebexl xlKf+*}**M*klliFxx***iWYIRW**********il****-iewww*a+****+1&tza.* * PERMIT APPLICATION PES PZR1'_`0LAT:C:J 7---ST FEE * * MAKE ALL REMITTANCE PAYABLE, TC : ' Sk"- .'5 C ;.)L?.'7 :'Y R EA U F � ***A*i**4*************71**** k#?**#*N A*T*#:k*****;YC/f#*wA k#*#7h*Y,'*yrt#•IC 1t x x•k PROPERTY OWNER: �Ov.I1 '� �-�No1►�? __— -• - - KATLING ADURESS; ta6Q r-10 5 ZkV" Lf*1 6P kJAG LD �� rfi�-F AFPL•!CANT /CONTAi.-V PERSON: . rk 4.~yo LICENSED SYS'� FMSrnNTRACTOR .....-'-- COMPA1 Y/^BA: t✓ Cc I �: uD0F: E':: 5, rY**ri.k�4+'#.k**,1•AklbNYr!****i.*w*xxx****•ttl**y*►its**xR>r *xw rx-RWWtr yix*trw +r rr**A+z n*rah FERMiT APPLICATION IS FCr . V NEW INS7ALLATIOr: UTERATII._/N ( ; R-_ a?P. LOCATION OF PROPOSRD IND. 7VjT) ..4'_1 SEII'AQ.;V Uj? pr ' `SA_r Sy_1;7EM: Legad Uescx•i rct . on ; to-grt_ _ Tax Parcel tizimber. : ���a � t5► 4L PhyS4.Ca l A Lddre$$: 7. r sW= 6-D B� ?ZAt7I[�t YFG (Check applicable ca-; gmr ) (residential Single Number rf Facroxi: _..._.....�� ( ) h,,rnber �- TYPE OF..,WATER SUPPLX : (Check applicab"-n.tego-V t we11 ( 1 sprincx f ) 8 ;z ft .:;e ( ) public Name of SZ-0121 .et : *Theae system eguireI sign b�, ec .e �r. �, "xo essi:n l rr��-e:eer. SIGNATURE-- Date l��Fh******7M Yr WW*W** **ak****#*#*#*#***nrri'k*elr•f 4tY+.wx***t**,erk4wye�fl fk�r .�►/a i*#•,k*.ram AMOUNT PAID: .�, �`� RECEIPT # : OAT'E I. CHECK # : I Post -It' Fax Note 7671 dale act �► Fran V , V ,`'4• AFL. E ff Community Development Department (970) 328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com EAGLE COUNTY, COLORADO Date: September 21, 1999 TO: Vanderwalker Construction Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Permit No. 1914-99. Tax Parcel # 2107-151-02-002. Property Location: 1609 Squaw Creek Rd., Edwards, CO., Snow residence. Enclosed is your ISDS Permit No. 1914-99. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files LKP Engineering, Luiza Petrovska Community Development Department (970) 328-8730 FAX (970)328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com October 20, 2000 Jack Snow 1000 Lions Ridge Loop Vail, CO 81657 EAGLE COUNTY, COLORADO Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Final of ISDS Permit #1914-99, Tax Parcel #2107-151-02-002. Property location: 1609 Squaw Creek Rd, Edwards, CO. Dear Mr. Snow: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, J44 Janet Kohl Environmental Health Department Eagle County Community Development ENCL: Informational Brochure Final ISDS Permit cc: files LRI LIYLitI Y(_LI\11YL7 11V1.. 1-Rur- CJl j C11 >>" Z' •rgin eerm in October 19, 2000 Mr. dock Snow R" 1000 Lionsridge Loop, Suite 3D "Vail, CO 81657 Dear Jack: RF:'nepectioa of Segtic System Istallation S11ow R.esidenee Lot 4A, Colorow, 1609 Squaw Creek Road Eagle County, Colorado Project No. 99169 - permit No. 1914-99 At the request of Bob Vanderwalker, on July 18, September 26, and October 18, 2000, we visited the construction site on Lot 4A, Colorow Subdivision, 1609 Squaw Creek Road, Eagle County, Colorado. The purpose of our site visits was to observe the installation of the septic system. They installed the system ill. overall compliance with the septic system desigtx, Drawitxg No_ 99169SD.DWG, dated September 13, 1999, The system drawing. They installed a 1 Spa -gallon, was itstalled as shown on the above-natxaed n., two compartno:ents, precast, concrete septic tank. The tank was installed on the west side of the west part of the proposed residence, 14 feet southwest from the westernmost corner' The distance from the septic tank to the leacbfield was 85 feet, Forty, Standard Infiltrator Chambers were installed in rive trenches. Each row of trenches contained eight. infiltrators- The infiltrators were connected. with serial distribution, In the last .infiltrator Of each trench, inspection ports were installed_ Horizontal distance from center to center of the trenches, was 9 feet or more, All piping was SDK-35, 4-ineb PVC. The depth of the trenches was no more than 36 inches. If you have any questions, please do not hesitate to call. Sincerely,,$a�i.ta� EEF Engine erin e+p� Pr�j�F,ow ip ° Luiza Fetrovska, e m President , °4�J " NA� � trykbt CC,. Ms. Heather Savalox, Eagle County .Environmental Health Division, fax. 328-0349 �;�MyFil°slcnsddOcIWPDQ�g1491598Si. Wr>:3 r;l l; Rnv )RRi7 PAnrnm& f'..1-j- ny/ten �vJ r I ..,uw�,ual t.4J1Uj¢C#4 �iAO L % WO) 926-9088 Tel + (970) 926-9089 Fax n T-1 Q_PfiMM TWI 1 1 1 • fl=OdM TI - Ct3f=1 C 1`1-11 II, ITV CAII I IJcnl Tu LKP ENGINEERING, INC. P.O. Box 2837 Edwards, CO 81632-2837 (970) 926-9088 Fax (970) 926-9089 PERCOLATION TEST RESULTS Client: Mr. Jack Snow RKD 1000 Lionsridge Loop, Suite 31) Vail, CO 81657 Project No.: 99169 Location: Lot 4A, Colorow Subdivision Eagle County, Colorado P-1 P-2 P-3 TIME/DEPTH 25-8/16" 24" 23-4/16" 10 8-4/16" 5-8/16" 10" 3-6/16" 9-2/16" 1-2/16" 10 10-12/16" 2-8/16" 11-8/16" 1-8/16" 10-4/16" 1-2/16" 10 12" 1-4/16" 12-10/16" 1-2/16" 11-6/16" 1-2/16" 10 13-4/16" 1-4/16" 13-8/16" 14/16" 12-8/16" 1-2/16" 10 14" 12/16" 14" 8/16" 13" 8/16" 10 14-12/16" 12/16" 14-8/16" 8/16" 13-8/16" 8/16" 10 15-8/16" 12/16" 15" 8/16" 14" 8/16" PERC RATE 13.33 MIN/INCH 20 MINANCH 20 MIN/INCH AVG PERC 18 MINUTES PER INCH Average Percolation Hole Diameter: 10 Inches Holes Presoaked: September 8, 1999 Test -Run: September 9, 1999 By: Peter Petrovski Soil Profile: 0 -2' Topsoil 2'-4' Dark reddish -brown, sandy clay 4'-8' Light brown, silty sand 1914-99 Tax vzl-u/-ID-L-ul-vul- Lot #4A, Colorow SNOW JOB NAME 1609 Squaw Creek Rd., Edwards JOB NO. ,00 1/1Q 1 �1/+ATIl1 AI BILL TO DATE ST RTED DATE- COMPLETED DATE BILLED 61C sc ce P 444 a ��� z �- �► �t-� �v ��► r7 I h-� fv� �z� C��. l JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Printed In U.S.A.