HomeMy WebLinkAbout757 Elsie Ave - 219723101010Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-024715-2022 Permit Type: OWTS Permit Work Classification: New Permit Status: Active Issue Date: 7/15/2022 Expires: 11/14/2022 On-Site Wastewater Treatement System Project Address Parcel Number 1 ELSIE AV, FULFORD,219723101010 Owner Information Address Todd Potestio 1932 Cherry ST Denver, CO 80220 Phone: (720) 323-1749 Cell: Email: modern.traditions.denver@gmail.com Inspections: For Inspections Call: (970) 328-8755 Engineer Phone Email Brock Civil LLC, Vern Brock (970) 471-2121 vern@brockcivil.com Contractor License Number Phone Email Brock Civil LLC vern@brockcivil.com(970) 471-2121OWTSPL-000177-20 22 Permitted Construction / Details: Install the OWTS vault exactly as depicted in the Brock Civil design dated, stamped and signed on July 14th, 2022 by Vern L Brock, PE. The vault is designed to serve as a holding tank for a 3 bedroom cabin in Fulford where a traditional OWTS with a soil treatment area cannot be accommodated due to lot size. The OWTS consists of a single sewer line exiting the cabin with a cleanout within 5 feet of the outer wall, followed by a two-compartment 1,500 gallon Valley Precast septic tank, with audible and visual high water alarm in the second compartment with floats set for alarm at 75% capacity. Maintain all elevations and setbacks. Note: Due to occurrences of septic tanks floating in the area, it is strongly recommended that the tank be anchored. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Danielle Salinsky Date July 15, 2022 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Friday, July 15, 2022 1 Inspection Result Eagle County, Colorado P.O. Box 179 500 Broadway Eagle, CO Phone: (970) 328-8730 Fax: (970) 328-7185 IVR Phone: 1-866-701-3307 Inspection Number: INSP-527863-2023 Permit Number: OWTS-024715-2022 Inspection Date: 12/08/2023 Inspector: Permit Type: OWTS Permit Inspection Type: OWTS Final Inspection Work Classification: NewOwner:Todd Potestio Job Address:1 ELSIE AV IVR Pin Number:196635 FULFORD, CO Project:<NONE> Parcel Number:219723101010 Contractor:Phone: (970) 328-0876 / Cell: (970) 471-2121Brock Civil LLC Inspection Status: Approved Inspection Notes Inspector Comments Added Item: Septic Tank A two-compartment 1,500 gallon Valley Precast septic tank, with audible and visual high water alarm in the second compartment with floats set for alarm at 75% capacity was installed. Added Item: Record Drawing Received 12/6/2023 from Brock Civil. Added Item: Record Photos Received 12/6/2023 from Brock Civil. Added Item: Site and Soil Received 7/11/2022. Added Item: Final Certification Letter Received 12/6/2023 from Brock Civil. Added Item: General Plan Received 7/11/2022. Added Item: Identification of Systems Contractor Spiegel Construction was the licensed installer. Friday, December 8, 2023 For more information visit: http://www.eaglecounty.us Page 1 of 1 Inspection Result Eagle County, Colorado P.O. Box 179 500 Broadway Eagle, CO Phone: (970) 328-8730 Fax: (970) 328-7185 IVR Phone: 1-866-701-3307 Inspection Number: FULFORD - 1 ELSIE - 527863 Permit Number: OWTS-024715-2022 Inspection Date: 12/12/2023 Inspector: Permit Type: OWTS Permit Inspection Type: OWTS Final Inspection Work Classification: NewOwner:Todd Potestio Job Address:1 ELSIE AV IVR Pin Number:196635 FULFORD, CO Project:<NONE> Parcel Number:219723101010 Contractor:Phone: (970) 328-0876 / Cell: (970) 471-2121Brock Civil LLC Inspection Status: Approved Inspection Notes Inspector Comments Added Item: Septic Tank A two-compartment 1,500 gallon Valley Precast septic tank, with audible and visual high water alarm in the second compartment with floats set for alarm at 75% capacity was installed. Added Item: Record Drawing Received 12/11/2023 from Brock Civil. Added Item: Record Photos Received 12/11/2023 from Brock Civil. Added Item: Site and Soil Received 7/11/2022. Added Item: Final Certification Letter Received 12/11/2023 from Brock Civil. Added Item: General Plan Received 7/11/2022. Added Item: Identification of Systems Contractor Spiegel Construction was the licensed installer. Tuesday, December 12, 2023 For more information visit: http://www.eaglecounty.us Page 1 of 1 Page 1 of 5 P.O. Box 23 Eagle, CO 8163 Cell 970-471-2121 December 11, 2023 VIA email: [environment@eaglecounty.us] Department of Environmental Health P.O Box 179, 500 Broadway Eagle, CO 81631 Re:Certification of Septic Tank Installation OWTS – 024715-2022 Property Address:Elsie Avenue, Fulford, Block 22, Lots 11-16 Eagle County Parcel 2197-231-01-010 Eagle, Colorado 81631 Property Owners:Potestio 9232 Cherry Street, Denver, Colorado 80220 Dear Environmental Health: Please accept this letter, record drawing and progress pictures as certification for the OWTS serving the permitted residential structure at Elsie Avenue, Fulford meets the approved OWTS design drawings in accordance with 5 CCR 1002-43 (Reg 43) and Eagle County Department of Health Regulations, as constructed by Chris Spiegel, License # OWTSSPL-302-2023. The minimum holding tank size for Fulford is 1,000 gallons. Due to (4) bedrooms, the owner installed a 1,500-gallon plastic holding tank. For this permit, it is asserted that the lot cannot accommodate an STA due to lot size, setbacks, etc. Septic Tank to be pumped as needed and to meet Reg 43. Regards, Vern L. Brock, P.E. Brock Civil, LLC cc: Todd Potestio Attached:Septic Record Drawing, 10/23 Progress Pictures Report Complete 2023 1 5 '15' 28'-6" 2 8 ' - 1 0 "9800'9799'9798'9797'9796'9795'9800'9801'9802'9803'9804'9805'9806'9807'9808'9809'9810'13%2%2%2%2%SEPTIC RECORD DRAWING BROCK CIVIL, LLC PO BOX 3644 EAGLE, COLORADO 81631 OFFICE (970) 471-2121 FAX (970) 328-0875 VERN@BROCKCIVIL.COMSHEETBLOCK 22 LOT 11-16SEPTIC RECORD DRAWINGPOTESTIO CABIN FULFORD, CO 1 ELSIE AVE(60' ROW)SHEET NOTES:1.THE HEREWITH DRIVEWAY AND PARKING PLAN (C1) IS FOR THE SOLE ACCESS OF THE OWNEROF SUBJECT LOTS 11-16 AND NOT A GUARANTEE OR LEGAL DETERMINATION OF THE ACCESSOF THE GENERAL PUBLIC ACROSS LOTS 11-16, BLK 22. Page | 1 PROGRESS PICTURES REPORT, COMPLETE 2023 OWTS – 024715- 2022 POTESTIO CABIN, PN 2197-231-01-010 1 ELSIE AVENUE, FULFORD, EAGLE COUNTY, CO 81631 Constructed by Licensed installer Chris Spiegel, dba Spiegel Excavation, LLC PICTURE 1 2022 CLEAN-OUT RISER AT HOUSE, GASKETED FLEXIBLE CONNECTIONS W/ SDR35 PIPE, CONVERSTION TO SCH 40 PIPE, 2% MIN SLOPE (SEE LEVEL ON PIPE) TOWARDS 1,500-GAL FRALO PLASTIC TANK, GASKET AT TANK ENTRANCE. 5 INCHES OF ¾ SCREEN ROCK BEDDING. 2 INCH FOAM BOARD INSULATION OVER PIPE WITH CAUTION TAPE, NOT SHOWN. ALL ROCK SCREENED FROM BACKFILL. Page | 1 PICTURE 2 2022 4 INCH SCHEDULE 40 AT 2% MIN. Page | 1 PICTURE 3 2022 SCH 40 PIPE AT 2 % MIN. ¾” SCREEN ROCK BACKFILL. Page | 1 PICTURE 4 2023 SEPTIC TANK WITH ESTABLISHED VEGATATION. AUDIBLE AND VISUAL ALARM AT NORTHEAST CORNER OF HOUSE IN PLAIN SIGHT. OWNER TO REPLACE BATTERY AS NEEED YEARLY MIN. PUMP TANK AS NEEDED. NO VEHICULAR TRAVEL OVER TANK OR PIPE. TANK PROTECTED Page | 1 Page | 1 Page | 1 Page | 1 Page | 1 1 5 '15' 28'-6" 2 8 ' - 1 0 "9800'9799'9798'9797'9796'9795'9800'9801'9802'9803'9804'9805'9806'9807'9808'9809'9810'13%2%2%2%2%SEPTIC SITE PLAN BROCK CIVIL, LLC PO BOX 3644 EAGLE, COLORADO 81631 OFFICE (970) 471-2121 FAX (970) 328-0875 VERN@BROCKCIVIL.COMSHEETBLOCK 22 LOT 11-16SEPTIC SITE PLANPOTESTIO CABIN FULFORD, CO 1 ELSIE AVE(60' ROW)SHEET NOTES:1.THE HEREWITH DRIVEWAY AND PARKING PLAN (C1) IS FOR THE SOLE ACCESS OF THE OWNEROF SUBJECT LOTS 11-16 AND NOT A GUARANTEE OR LEGAL DETERMINATION OF THE ACCESSOF THE GENERAL PUBLIC ACROSS LOTS 11-16, BLK 22. Professional Services July 6, 2022 Potestio Cabin Lots 11663 Block 22 1 ELSIE AVE Fulford, CO DESIGN CALCULATIONS FOR SEPTIC SYSTEM REFERENCES Eagle County Public Health Agency On-Site Wastewater Treatment System Regulations adopted May 13, 2014 (“Regulations”). Colo. Dept. of Public Health and Environment Regulation #43 5 CCR 1002-43. DESIGN FLOWS Number of bedrooms = 2 Number of persons per bedroom = 2 (design flow) Single Family Residential Design Flows = 75 gallons/day/person Q design = 2 bdrms x 2 persons/bdrm x 75 gallons/person/day = 300 gpd Owner to recognize that tank is only for holding and that more frequent pumping may be required. SEPTIC TANK & PIPE CONSTRUCTION: Install septic tank level with sand gravel bedding. Install the delivery pipe from the residence to the septic tank 2% slope, Schedule 40 PVC (ASTM D 2665) or SDR 35. Insulate under driveway or any parking area with 2” rigid insulation. Septic tank to have risers brought to or above final grade and shall have a secure locking mechanism. ALARM: A visual and audible alarm shall be incorporated into the controls and electrical connections. Alarm to be in an open area or area easily visible. NOTES: 1.The building sewer line from the house to the septic tank shall have a slope of ¼ inch per foot (2%). Bends in the building sewer shall be limited to 45 degrees. 2.Use topsoil for vegetative cover. 3.Avoid vehicle traffic, animal concentrated loads and irrigation over the system. Fencing advised. 4.The Septic System Installation shall be inspected by the Design Engineer prior to backfill. 5.All installations shall meet the rules and regulations of the Eagle County Environmental Health Department. 6.Electrical requirements of alarm to be determined by Electrical Contractor prior to construction. In general, all electrical to be 18” below grade. 7.Pump septic tank every 2-3 years minimum to prevent deterioration of concrete & overflow 8.Installer must be licensed installer in Eagle County; see permit. MINIMUM DIMENSIONS TO FACILITIES ACTUAL (MIN. REQ'D) SEPTIC TANK TO BUILDING 6 FT (5 FT) SEPTIC TANK TO WATER LINE 15 FT (10 FT) BUILDING SEWER TO WATER LINE 15 FT (10 FT) See 43.7, Table 7-1 for further information and requirements if changes are made to assure proper clearances. Top View Section View 129" 132" 56"53" Flexible Boot Butyl Rubber Sealant 4" 5" 68" 68" 20" Clear Access TANK ID 49" 19"19"19" · · · · · · · · · · · · ·