Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
 
     
     
    HomeMy WebLinkAbout757 Elsie Ave - 219723101010Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone:  (970) 328-8730
Fax:  (970) 328-7185 
Permit
Permit No. OWTS-024715-2022
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 7/15/2022 Expires: 11/14/2022
On-Site Wastewater 
Treatement System
Project Address Parcel Number
1 ELSIE AV, FULFORD,219723101010
Owner Information Address
Todd Potestio 1932  Cherry ST
Denver, CO 80220 
Phone: (720) 323-1749
Cell: 
Email: modern.traditions.denver@gmail.com
Inspections:
For Inspections Call: (970) 
328-8755
Engineer Phone Email
Brock Civil LLC, Vern  Brock (970) 471-2121 vern@brockcivil.com
Contractor License Number Phone Email
Brock Civil LLC vern@brockcivil.com(970) 471-2121OWTSPL-000177-20
22
Permitted Construction / Details:
Install the OWTS vault exactly as depicted in the Brock Civil design dated, stamped and signed on July 14th, 2022 by 
Vern L Brock, PE. The vault is designed to serve as a holding tank for a 3 bedroom cabin in Fulford where a 
traditional OWTS with a soil treatment area cannot be accommodated due to lot size. 
The OWTS consists of a single sewer line exiting the cabin with a cleanout within 5 feet of the outer wall, followed 
by a two-compartment 1,500 gallon Valley Precast septic tank, with audible and visual high water alarm in the 
second compartment with floats set for alarm at 75% capacity. Maintain all elevations and setbacks. 
Note: Due to occurrences of septic tanks floating in the area, it is strongly recommended that the tank be anchored. 
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior 
to backfilling any component of the OWTS.  The design engineer is responsible for conducting all inspections 
necessary to certify the installation and assure the functionality of the system.  System certification, along with 
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health 
prior to the use of the system or occupancy of the dwelling.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS 
OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Salinsky
Date
July 15, 2022
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM 
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND 
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS 
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, 
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Friday, July 15, 2022 1
Inspection Result
Eagle County, Colorado
P.O. Box 179 500 Broadway Eagle, CO
Phone: (970) 328-8730   Fax: (970) 328-7185
IVR Phone: 1-866-701-3307
Inspection Number:  INSP-527863-2023 Permit Number:  OWTS-024715-2022
Inspection Date: 12/08/2023
Inspector: 
Permit Type: OWTS Permit
Inspection Type: OWTS Final Inspection
Work Classification: NewOwner:Todd Potestio
Job Address:1 ELSIE AV IVR Pin Number:196635
FULFORD, CO Project:<NONE>
Parcel Number:219723101010
Contractor:Phone: (970) 328-0876 / Cell: (970) 471-2121Brock Civil LLC
Inspection Status: Approved
Inspection Notes
Inspector Comments
Added Item: Septic Tank
A two-compartment 1,500 gallon Valley Precast septic tank, with audible and visual high water alarm in 
the second compartment with floats set for alarm at 75% capacity was installed.
Added Item: Record Drawing
Received 12/6/2023 from Brock Civil.
Added Item: Record Photos
Received 12/6/2023 from Brock Civil.
Added Item: Site and Soil
Received 7/11/2022.
Added Item: Final Certification Letter
Received 12/6/2023 from Brock Civil.
Added Item: General Plan
Received 7/11/2022.
Added Item: Identification of Systems Contractor
Spiegel Construction was the licensed installer.
Friday, December 8, 2023 
For more information visit: http://www.eaglecounty.us
Page 1 of 1
Inspection Result
Eagle County, Colorado
P.O. Box 179 500 Broadway Eagle, CO
Phone: (970) 328-8730   Fax: (970) 328-7185
IVR Phone: 1-866-701-3307
Inspection Number:  FULFORD - 1 ELSIE - 
527863 
Permit Number:  OWTS-024715-2022
Inspection Date: 12/12/2023
Inspector: 
Permit Type: OWTS Permit
Inspection Type: OWTS Final Inspection
Work Classification: NewOwner:Todd Potestio
Job Address:1 ELSIE AV IVR Pin Number:196635
FULFORD, CO Project:<NONE>
Parcel Number:219723101010
Contractor:Phone: (970) 328-0876 / Cell: (970) 471-2121Brock Civil LLC
Inspection Status: Approved
Inspection Notes
Inspector Comments
Added Item: Septic Tank
A two-compartment 1,500 gallon Valley Precast septic tank, with audible and visual high water alarm in 
the second compartment with floats set for alarm at 75% capacity was installed.
Added Item: Record Drawing
Received 12/11/2023 from Brock Civil.
Added Item: Record Photos
Received 12/11/2023 from Brock Civil.
Added Item: Site and Soil
Received 7/11/2022.
Added Item: Final Certification Letter
Received 12/11/2023 from Brock Civil.
Added Item: General Plan
Received 7/11/2022.
Added Item: Identification of Systems Contractor
Spiegel Construction was the licensed installer.
Tuesday, December 12, 2023 
For more information visit: http://www.eaglecounty.us
Page 1 of 1
Page 1 of 5 
  P.O. Box 23
Eagle, CO 8163
Cell   970-471-2121
December 11, 2023
VIA email: [environment@eaglecounty.us]
Department of Environmental Health
P.O Box 179, 500 Broadway
Eagle, CO 81631
Re:Certification of Septic Tank Installation
OWTS –  024715-2022
Property Address:Elsie Avenue, Fulford, Block 22, Lots 11-16
Eagle County Parcel 2197-231-01-010
Eagle, Colorado 81631
Property Owners:Potestio
9232 Cherry Street,
Denver, Colorado 80220
Dear Environmental Health:
Please accept this letter, record drawing and progress pictures as certification for the 
OWTS serving the permitted residential structure at Elsie Avenue, Fulford meets the 
approved OWTS design drawings in accordance with 5 CCR 1002-43 (Reg 43) and Eagle 
County Department of Health Regulations, as constructed by Chris Spiegel, License # 
OWTSSPL-302-2023.  The minimum holding tank size for Fulford is 1,000 gallons.  Due to 
(4) bedrooms, the owner installed a 1,500-gallon plastic holding tank. For this permit, it is 
asserted that the lot cannot accommodate an STA due to lot size, setbacks, etc.  
Septic Tank to be pumped as needed and to meet Reg 43.
Regards,
Vern L. Brock, P.E.
Brock Civil, LLC
cc:  Todd Potestio 
Attached:Septic Record Drawing, 10/23
                Progress Pictures Report Complete 2023
1
5
'15'
28'-6"
2
8
'
-
1
0
"9800'9799'9798'9797'9796'9795'9800'9801'9802'9803'9804'9805'9806'9807'9808'9809'9810'13%2%2%2%2%SEPTIC RECORD DRAWING
BROCK CIVIL, LLC
PO BOX 3644
EAGLE, COLORADO 81631
OFFICE (970) 471-2121 FAX (970) 328-0875
VERN@BROCKCIVIL.COMSHEETBLOCK 22 LOT 11-16SEPTIC RECORD DRAWINGPOTESTIO CABIN
FULFORD, CO
1 ELSIE AVE(60' ROW)SHEET NOTES:1.THE HEREWITH DRIVEWAY AND PARKING PLAN (C1) IS FOR THE SOLE ACCESS OF THE OWNEROF SUBJECT LOTS 11-16 AND NOT A GUARANTEE OR LEGAL DETERMINATION OF THE ACCESSOF THE GENERAL PUBLIC ACROSS LOTS 11-16, BLK 22.
Page | 1
PROGRESS PICTURES REPORT, COMPLETE 2023
OWTS – 024715- 2022
POTESTIO CABIN, PN 2197-231-01-010
1 ELSIE AVENUE, FULFORD, EAGLE COUNTY, CO 81631
Constructed by Licensed installer Chris Spiegel, dba Spiegel Excavation, LLC
PICTURE 1 2022
CLEAN-OUT RISER AT HOUSE, GASKETED FLEXIBLE CONNECTIONS 
W/ SDR35 PIPE, CONVERSTION TO SCH 40 PIPE, 2% MIN SLOPE (SEE 
LEVEL ON PIPE) TOWARDS 1,500-GAL FRALO PLASTIC TANK, 
GASKET AT TANK ENTRANCE.  5 INCHES OF ¾ SCREEN ROCK 
BEDDING. 2 INCH FOAM BOARD INSULATION OVER PIPE WITH 
CAUTION TAPE, NOT SHOWN.
ALL ROCK SCREENED FROM BACKFILL.
Page | 1
PICTURE 2 2022
4 INCH SCHEDULE 40 AT 2% MIN. 
Page | 1
PICTURE 3 2022
SCH 40 PIPE AT 2 % MIN. ¾” SCREEN ROCK BACKFILL.
Page | 1
PICTURE 4 2023   SEPTIC TANK WITH ESTABLISHED 
VEGATATION.   AUDIBLE AND VISUAL ALARM AT NORTHEAST 
CORNER OF HOUSE IN PLAIN SIGHT.  OWNER TO REPLACE 
BATTERY AS NEEED YEARLY MIN.
PUMP TANK AS NEEDED.
NO VEHICULAR TRAVEL OVER TANK OR PIPE. TANK PROTECTED
Page | 1
Page | 1
Page | 1
Page | 1
Page | 1
1
5
'15'
28'-6"
2
8
'
-
1
0
"9800'9799'9798'9797'9796'9795'9800'9801'9802'9803'9804'9805'9806'9807'9808'9809'9810'13%2%2%2%2%SEPTIC SITE PLAN
BROCK CIVIL, LLC
PO BOX 3644
EAGLE, COLORADO 81631
OFFICE (970) 471-2121 FAX (970) 328-0875
VERN@BROCKCIVIL.COMSHEETBLOCK 22 LOT 11-16SEPTIC SITE PLANPOTESTIO CABIN
FULFORD, CO
1 ELSIE AVE(60' ROW)SHEET NOTES:1.THE HEREWITH DRIVEWAY AND PARKING PLAN (C1) IS FOR THE SOLE ACCESS OF THE OWNEROF SUBJECT LOTS 11-16 AND NOT A GUARANTEE OR LEGAL DETERMINATION OF THE ACCESSOF THE GENERAL PUBLIC ACROSS LOTS 11-16, BLK 22.
Professional Services  
July 6, 2022
Potestio Cabin
Lots 11663 Block 22
1 ELSIE AVE
Fulford, CO
DESIGN CALCULATIONS FOR SEPTIC SYSTEM
REFERENCES
Eagle County Public Health Agency On-Site Wastewater Treatment System Regulations adopted May 13, 2014 (“Regulations”).
Colo. Dept. of Public Health and Environment Regulation #43 5 CCR 1002-43.
DESIGN FLOWS
Number of bedrooms = 2
Number of persons per bedroom = 2 (design flow)
Single Family Residential Design Flows = 75 gallons/day/person
Q design = 2 bdrms x 2 persons/bdrm x 75 gallons/person/day = 300 gpd
Owner to recognize that tank is only for holding and that more frequent pumping may be required.
SEPTIC TANK & PIPE CONSTRUCTION:    Install septic tank level with sand gravel bedding.  Install the delivery pipe from the
residence to the septic tank 2% slope, Schedule 40 PVC (ASTM D 2665) or SDR 35.  Insulate under driveway or any parking area with 2”
rigid insulation.  Septic tank to have risers brought to or above final grade and shall have a secure locking mechanism.
ALARM:  A visual and audible alarm shall be incorporated into the controls and electrical connections.  Alarm to be in an open area or
area easily visible.
NOTES:
1.The building sewer line from the house to the septic tank shall have a slope of ¼ inch per foot (2%).  Bends in the building sewer shall
be limited to 45 degrees.
2.Use topsoil for vegetative cover.
3.Avoid vehicle traffic, animal concentrated loads and irrigation over the system.  Fencing advised.
4.The Septic System Installation shall be inspected by the Design Engineer prior to backfill.
5.All installations shall meet the rules and regulations of the Eagle County Environmental Health Department.
6.Electrical requirements of alarm to be determined by Electrical Contractor prior to construction.  In general, all electrical to be 18”
below grade.
7.Pump septic tank every 2-3 years minimum to prevent deterioration of concrete & overflow
8.Installer must be licensed installer in Eagle County; see permit.
MINIMUM DIMENSIONS TO FACILITIES
                ACTUAL       (MIN. REQ'D)
SEPTIC TANK TO BUILDING   6 FT            (5 FT)
SEPTIC TANK TO WATER LINE  15 FT            (10 FT)
BUILDING SEWER TO WATER LINE  15 FT            (10 FT)
See 43.7, Table 7-1 for further information and requirements if changes are made to assure proper clearances.
Top
View
Section
View
129"
132"
56"53"
Flexible
Boot 
Butyl Rubber
Sealant
4"
5"
68"
68"
 20" Clear Access
TANK
ID
49"
19"19"19"
·
·
·
·
·
·
·
·
·
·
·
·
·