HomeMy WebLinkAbout3148 Upper Cattle Creek Rd - 239123200001Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-017720-2019
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 11/13/2019 Expires: 9/14/2020
On-Site Wastewater
Treatement System
Project Address Parcel Number
3148 Upper Cattle Creek RD, 239123200001
Owner Information Address
James & Mary Griffith 3148 Upper Cattle Creek RD
Carbondale, CO 81623
Phone:
Cell:
Email: mimidork@aol.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
All Service Septic, Richard Petz (970) 704-0484 richard@allservicespetic.c
om
Contractor License Number Phone Email
Hughes Excavating Company travishughes501@reagan.
com
(970) 963-2004OWTSPL-000076-20
20
Permitted Construction / Details:
Install the OWTS exactly as depicted in the All Service Septic design dated November 6, 2019, stamped and signed
by Richard H. Petz, PE. The system is designed to serve the newly proposed three bedroom single family residence.
The OWTS consists of a 1,500 gallon, two-compartment Valley Precast septic tank with an Orenco Propak high head
effluent pump, model PF3005, installed in an Orenco Biotube Vault with floats set to deliver approximately 80
gallons (before drainback) of effluent to an automatic distribution valve, set at the high point of the system and
made accessible at grade, followed by 504 square feet of soil treatment area (STA) (after to reductions taken for
pressure dosing and use of chamber media). The STA consists of 42 Quick4 Plus Standard Infiltrator media arrange
in three shallow trenches, with 14 pressurized chambers in each, and inspection ports installed in both ends of each
trench, with 6 feet of separation between trenches, per design. Install inspection ports in both ends of each trench.
Maintain all setbacks and elevations as shown on design.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure functionality of the system. System certification, along with photos
and a record drawing is required to be submitted to, and approved by, Eagle County Environmental Health prior to
the use of the system or occupancy of the dwelling.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Claire Lewandowski
Date
November 13, 2019
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Tuesday, May 12, 2020 1
PERMIT INSPECTION HISTORY REPORT (OWTS-017720-2019)
FOR EAGLE COUNTY GOVERNMENT
OWTS Permit 10/22/2019Application Date:Permit Type:Owner:James & Mary Griffith
ParcelNew11/13/2019Work Class:Issue Date:239123200001
Active 03/22/2021Expiration Date:Status:Address: 3148 Upper Cattle Creek RD
CO
189262IVR Number:
Scheduled
Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection CompleteActual
Start Date
OWTS Final
Inspection
INSP-504681-2020 Requested Danielle Sell Incomplete
COMMENTS PassedChecklist Item
Septic Tank Observed in compliance with design and
regulations.
Yes
Record Drawing Received record drawing with final
certification from All Service Septic.
Drawing missing location of components
from two identifiable points. Request those
added to record drawing.
No
Record Photos Received. Sufficient.Yes
Final Certification Letter Received. Stamped, signed, and dated
December 21, 2020 by Richard H. Petz, PE.
Yes
Pressure Distribution Emailed Carla 12/22/20 to verify start up
and squirt test.
No
General Plan In compliance with approved design.Yes
Soil Treatment Area (STA)Arc 36 chambers used instead of Quick4,
STA equivalent to 504 square feet
required. Approved.
Yes
Identification of Systems
Contractor
Eagle County 2020 licensed contractor
Hughes Excavation completed the
installation.
Yes
December 22, 2020 Page 1 of 1P.O. Box 179, 500 Broadway, Eagle, CO 81631-0179
Inspection Result
Eagle County, Colorado
P.O. Box 179 500 Broadway Eagle, CO
Phone: (970) 328-8730 Fax: (970) 328-7185
IVR Phone: 1-866-701-3307
Inspection Number: El Jebel - 3148 Upper
Cattle Creek - 504681
Permit Number: OWTS-017720-2019
Inspection Date: 12/22/2020
Inspector: Lewandowski, Claire
Permit Type: OWTS Permit
Inspection Type: OWTS Final Inspection
Work Classification: NewOwner:James & Mary Griffith
Job Address: 3148 Upper Cattle Creek RD IVR Pin Number:189262
CO Project:<NONE>
Parcel Number:239123200001
Contractor:Phone: (970) 963-2004 / Cell: (970) 618-0445Hughes Excavating Company
Inspection Status: Approved
Inspection Notes
The above-referenced permit has been inspected and finalized.
The Onsite Wastewater Treatment System (OWTS) was designed and installed to serve the new three bedroom residence on
the above property. Additional information about the maintenance of your septic system needs can be accessed through our
website links, provided on the Environmental Health Department’s septic system resource page.
Be aware that changes in the use of your property or alterations of your building may require commensurate changes to, or
relocation of, your septic system. Landscape features, trees with taproots, irrigation systems, and parking areas above the
soil treatment area can cause a premature system failure. It is equally important that you notice and immediately repair
dripping faucets and hissing toilets as this will certainly cause the system to fail. If you have any questions regarding this
information, please contact us at (970) 328-8755 and reference the OWTS septic permit number.
Inspector Comments
Added Item: Septic Tank
Observed in compliance with design and regulations.
Added Item: Record Drawing
Received record drawing with final certification from All Service Septic. The sewer and effluent pipe
have tracer wire running along their length and are approved as an alternative to the having the
distances marked on the record drawing.
Added Item: Record Photos
Received. Sufficient.
Added Item: Final Certification Letter
Received. Stamped, signed, and dated December 21, 2020 by Richard H. Petz, PE.
Added Item: Pressure Distribution
Start up of pump and control panel were completed by Valley Precast on December 8, 2020.
Wednesday, December 23, 2020
For more information visit: http://www.eaglecounty.us
Page 1 of 2
Added Item: General Plan
In compliance with approved design.
Added Item: Soil Treatment Area (STA)
Arc 36 chambers used instead of Quick4, STA equivalent to 504 square feet required.
Added Item: Identification of Systems Contractor
Eagle County 2020 licensed contractor Hughes Excavation completed the installation.
Wednesday, December 23, 2020
For more information visit: http://www.eaglecounty.us
Page 2 of 2
December 19, 2020 Project No. C1464
Jim Griffith
jumgriffit@aol.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
3148 Upper Cattle Creek Road
Eagle County, Colorado
Permit Number OWTS-017720-2019
Jim,
ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS)
on May 18, 2019 for the subject property. Hughes Excavation installed the system.
The OWTS design is based on 3-bedrooms. An average daily wastewater flow of 450 GPD was used.
A new, 4-inch diameter SDR-35 sewer line with a double sweep clean out and minimum 2% grade to the
septic tank was installed. The installation included a 1500-gallon, two-compartment Valley Precast
concrete septic tank with an Orenco® ProPak pumping system and PF3005 pump. There is an effluent
filter in the second compartment of the septic tank. The effluent filter in the pump chamber must be
cleaned annually, or as needed.
The floats were set to dose approximately 80 gallons each pump cycle, allowing for approximately 40
gallons of drain back into the pump chamber after each pump cycle. The pumping system was wired and
is operational. We recommend Valley Precast out of Buena Vista perform start up on the pumping
system.
A 1.5-inch diameter Schedule 40 pump line was installed from the pump to an Orenco® automatic
distributing valve (ADV), model 6403. This pump line must have a minimum 1% grade for proper drain back
into the tank after each pump cycle. The ADV was placed at a high point in the system in an insulated riser
with access from grade.
Effluent is pressure dosed through 1.5-inch diameter pipes to three trenches, each with 12 ‘ARC’ ADS
chambers, for a total of 36 chambers and 540 square feet of infiltrative area. There was at least 4-feet of
undisturbed soil between each trench. Effluent is pressure dosed to 1.5-inch diameter laterals, which
were hung with zip ties from the underside of the chambers. Laterals have 5/32-inch diameter orifices
facing up, with the exception of the first and last holes facing down for drainage. The orifices were
placed 3-feet on center. Each lateral ends in a 90 degree ell facing up with a ball valve for flushing.
Valves were placed in a valve box, accessible from grade, for access. Inspection ports were placed at the
beginning and end of each trench. Ports may be cut to grade and covered with a valve box for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are
made to the OWTS in the future. Any additional OWTS construction must be according to the county
regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By:
Carla Ostberg, MPH, REHS Richard H. Petz,
Clean outs
12/21/2020
Sewer line to septic tank
1500 gal tank inlet tee
Pump chamber (float tree not attached in this photo) pump line to STA
ADV
Chamber trenches view of ADV and trenches
Inspection ports and flushing valves being installed (used flex pipe rather than specified flushing valves)
View of trenches inspection ports
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-017720-2019
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 11/13/2019 Expires: 9/14/2020
On-Site Wastewater
Treatement System
Project Address Parcel Number
3148 Upper Cattle Creek RD, 239123200001
Owner Information Address
James & Mary Griffith 3148 Upper Cattle Creek RD
Carbondale, CO 81623
Phone:
Cell:
Email: mimidork@aol.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
All Service Septic, Richard Petz (970) 704-0484 richard@allservicespetic.c
om
Contractor License Number Phone Email
Hughes Excavating Company travishughes501@reagan.
com
(970) 963-2004OWTSPL-000076-20
20
Permitted Construction / Details:
Install the OWTS exactly as depicted in the All Service Septic design dated November 6, 2019, stamped and signed
by Richard H. Petz, PE. The system is designed to serve the newly proposed three bedroom single family residence.
The OWTS consists of a 1,500 gallon, two-compartment Valley Precast septic tank with an Orenco Propak high head
effluent pump, model PF3005, installed in an Orenco Biotube Vault with floats set to deliver approximately 80
gallons (before drainback) of effluent to an automatic distribution valve, set at the high point of the system and
made accessible at grade, followed by 504 square feet of soil treatment area (STA) (after to reductions taken for
pressure dosing and use of chamber media). The STA consists of 42 Quick4 Plus Standard Infiltrator media arrange
in three shallow trenches, with 14 pressurized chambers in each, and inspection ports installed in both ends of each
trench, with 6 feet of separation between trenches, per design. Install inspection ports in both ends of each trench.
Maintain all setbacks and elevations as shown on design.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure functionality of the system. System certification, along with photos
and a record drawing is required to be submitted to, and approved by, Eagle County Environmental Health prior to
the use of the system or occupancy of the dwelling.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Claire Lewandowski
Date
November 13, 2019
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Tuesday, May 12, 2020 1
832‐R‐13‐002
November 6, 2019 Project No. C1464
Jim Griffith
jumgriffit@aol.com
Subsurface Investigation and Onsite Wastewater Treatment System Design
3-Bedroom Residence
3148 Upper Cattle Creek Road
Eagle County, Colorado
Jim
ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater
treatment system (OWTS) design for the subject residence. The almost 600-acre property is located
outside of Basalt, in an area where OWTSs and wells are necessary. The original design has been
modified to specify a larger septic tank to meet the required 48-hour retention time. Original design
documents dated August 28, 2019 should be replaced with these dated November 6, 2019.
Legal Description: See Enclosed “Property Report Card” from Eagle County Assessor’s website
Parcel ID: 2391-232-00-001
SITE CONDITIONS
The property is developed with two single-family residences and a mobile home. All are served by
separate OWTSs not addressed in this design.
A new, 3-bedroom, single-family residence is proposed. This design references the OWTS that will serve
the new residence.
The proposed building site on the property is in a large meadow. The proposed soil treatment area
(STA) is located to the south of the proposed residence and upgradient. The meadow is covered with
native grasses.
There is an abandoned irrigation ditch to the south of the proposed STA. This ditch does not run. A
minimum 25-foot setback will be maintained from the STA to the abandoned ditch.
The residence will be served by a private well. The well will be located to the north east of the proposed
residence. The well will be located greater than 50-feet from the proposed septic tank and greater than
100-feet from the proposed STA.
Table 1 describes the minimum required setback of OWTS components to physical features on the
property compared to approximate, proposed setback distances.
Table 1
OWTS Components and
Physical Features
Minimum Required Setback Approximate Proposed Setback
House to Septic Tank 5’ 20’
Septic Tank to Well 50’ 66’
Page 2
Septic Tank to Water Course 50’ n/a
STA to House 20’ 212’
STA to Well 100’ 351’
STA to Water Course 50’ n/a
SUBSURFACE
The subsurface was investigated on June 4 and July 29, 2019 by digging seven soil profile test pit
excavations (Test Pits). A visual and tactile soil analysis was completed by Carla Ostberg at the time of
excavation.1
The two soil horizons encountered on the property were dark brown clay loam topsoil underlain by light
brown to tan calcareous sandy silt which is sometimes described as “caliche”. The material grades out
with finer particles similar to clay; however, accepts water.
The first set of Test Pits (Test Pits #1 - #4) were excavated to the north and east of the proposed house
location. With the exception of Test Pit #1, all Test Pits had a topsoil horizon extending deeper than 4-feet
below native grade. No bedrock or groundwater was encountered.
The second set of Test Pits (Test Pits #5 - #7) were excavated to the south of the proposed residence.
The materials encountered in Test Pit #6 consisted of dark brown, clay loam to 3-feet, underlain by light
brown to tan “caliche” to a maximum depth explored of 7.0-feet. No bedrock or groundwater was
encountered.
The materials encountered in Test Pit #7 were consistent with those encountered in Test Pit #6. The test
pit was explored to a maximum depth of 7.0-feet. No bedrock or groundwater was encountered.
A sample was taken from below the dark brown topsoil horizon in Test Pit #6. The sample formed a ball
and a ribbon less than 1-inch in length before breaking. Soil structure shape was loose to blocky,
structure grade was moderate, consistent was loose to friable, and texture was more smooth than gritty.
STA sizing is based on Soil Type 2A to be conservative.
A long term acceptance rate (LTAR) of 0.5 gallons per square foot will be used to design the
OWTS.
Test Pits #1 - #4 excavated to the north of the proposed residence
1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
Page 3
Test Pit #1
Sieved sample of topsoil sieved sample of ‘caliche’
Page 4
Test Pit #2 had mottling a 7-feet, possible leakage from ditch that was lined 7-8 years ago
Topsoil to 6-feet
Page 5
Test Pits #5 - #7 excavated to the south of the proposed residence
Test pits, looking north
Test Pit #4
Page 6
Test Pit #5
Test Pit #6
Page 7
Caliche at 3-feet
Page 8
View of Test Pits #5-7 backfill from Test Pit #7
DESIGN SPECIFICATIONS
Design Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms = 450 GPD
LTAR = 0.6 GPD/SF
450 GPD / 0.5 GPD/SF x 0.8 (pressure dosed trenches) x 0.7 (chambers) = 504 SF
The OWTS design is based on 3-bedrooms. An average daily wastewater flow of 450 GPD will be used.
For the purposes of this OWTS design, Benchmark Elevation at grade 7423.25’ has been established as
100’ (finished floor). ALL SERVICE septic, LLC should be notified of any discrepancies or problems with
grade elevations of proposed components during installation of the OWTS.
OWTS Component Minimum Elevation
Primary Tank Inlet Invert 97.5’ (7420.75’)
Automatic Distributing Valve 102.75’ (7426’)
Infiltrative Surface 102.25’ (7425.5’)
A new, 4-inch diameter SDR-35 sewer line with a double sweep clean out and minimum 2% grade to the
septic tank must be installed.
The installation must include a 1500-gallon, two-compartment Valley Precast concrete septic tank with an
Orenco® ProPak pumping system and PF3005 pump. The floats must be set to dose approximately 80
gallons each pump cycle, allowing for approximately 40 gallons of drain back into the pump chamber
after each pump cycle.
Risers must be installed on the septic tank to bring access to grade. Handle extensions on both the
effluent filter and float tree must be installed if the riser height exceeds 1-foot. The control panel must be
located within line of sight of the septic tank. We recommend Valley Precast out of Buena Vista perform
start up on the pumping system.
A 1.5-inch diameter Schedule 40 pump line must be installed from the pump to an Orenco® automatic
distributing valve (ADV), model 6403. This pump line must have a minimum 1% grade for proper drain back
into the tank after each pump cycle. The ADV must be placed at a high point in the system and be placed in
an insulated riser with access from grade. Screened rock must be placed below the ADV to support the
ADV and to assure the clear pipes exiting the ADV remain visible for future inspection and maintenance.
Page 9
Effluent will be pressure dosed through 1.5-inch diameter pipes to three trenches, each with 14 ‘Quick 4’
Infiltrator® chambers, for a total of 42 chambers and 504 square feet of infiltrative area. There must be
at least 4-feet of undisturbed soil between each trench, although we recommend at least 6-feet. Effluent
will be pressure dosed to 1.5-inch diameter laterals, which must be hung with zip ties from the underside
of the chambers. Laterals will have 5/32-inch diameter orifices facing up, with the exception of the first
and last holes facing down for drainage. Orenco® Orifice Shields may be placed under each downward-
facing orifice. The orifices must be placed 3-feet on center. Each lateral must end in a 90 degree ell
facing up with a ball valve for flushing. Valves may be placed in a valve box, accessible from grade, for
access. Inspection ports must be placed at the beginning and end of each trench. Ports may be cut to
grade and covered with a valve box for access.
The component manufacturers are typical of applications used by contractors and engineers in this area.
Alternatives may be considered or recommended by contacting our office. Construction must be
according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided
by Eagle County Environmental Health Department, and this design.
INSTALLATION CONTRACTOR
ALL SERVICE septic, LLC expects that the installer be experienced and qualified to perform the scope of
work outlined in this design. The installer must review this design thoroughly and coordinate with our office
in advance of installation. Any additional conditions in this design or county permit must be completed and
documented prior to final approval of the OWTS installation. Communication between the installer and this
office is expected throughout the installation.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be
performed before backfill, after placement of OWTS components. Septic tanks, distribution devices,
pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic,
LLC should be notified 48 hours in advance to observe the installation.
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over
the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Page 10
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Livestock should not graze on the STA. Plumbing fixtures should be
checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or
leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high
water conditions and shall be connected to a control breaker separate from the high water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be
according to the county regulations. Requirements not specified in this report must follow applicable
county regulations. The contractor should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working. Licensing of Systems Contractors
may be required by county regulation.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By:
Carla Ostberg, MPH, REHS
11/6/19
Pump Selection for a Pressurized System - Single Family Residence Project
Griffith Residence
Parameters
Discharge Assembly Size
Transport Length Before Valve
Transport Pipe Class
Transport Line Size
Distributing Valve Model
Transport Length After Valve
Transport Pipe Class
Transport Pipe Size
Max Elevation Lift
Manifold Length
Manifold Pipe Class
Manifold Pipe Size
Number of Laterals per Cell
Lateral Length
Lateral Pipe Class
Lateral Pipe Size
Orifice Size
Orifice Spacing
Residual Head
Flow Meter
'Add-on' Friction Losses
1.25
375
40
1.50
6403
30
40
1.50
4.5
0
40
1.50
3
56
40
1.50
5/32
3
5
None
0
inches
feet
inches
feet
inches
feet
feet
inches
feet
inches
inches
feet
feet
inches
feet
Calculations
Minimum Flow Rate per Orifice
Number of Orifices per Zone
Total Flow Rate per Zone
Number of Laterals per Zone
% Flow Differential 1st/Last Orifice
Transport Velocity Before Valve
Transport Velocity After Valve
0.68
19
12.9
1
2.0
2.0
2.0
gpm
gpm
%
fps
fps
Frictional Head Losses
Loss through Discharge
Loss in Transport Before Valve
Loss through Valve
Loss in Transport after Valve
Loss in Manifold
Loss in Laterals
Loss through Flowmeter
'Add-on' Friction Losses
1.2
4.1
2.6
0.3
0.0
0.2
0.0
0.0
feet
feet
feet
feet
feet
feet
feet
feet
Pipe Volumes
Vol of Transport Line Before Valve
Vol of Transport Line After Valve
Vol of Manifold
Vol of Laterals per Zone
Total Vol Before Valve
Total Vol After Valve
39.7
3.2
0.0
5.9
39.7
9.1
gals
gals
gals
gals
gals
gals
Minimum Pump Requirements
Design Flow Rate
Total Dynamic Head
12.9
17.9
gpm
feet
0 5 10 15 20 25 30 35 40
0
50
100
150
200
250
300
Net Discharge (gpm)
PumpData
PF3005 High Head Effluent Pump
30 GPM, 1/2HP
115/230V 1Ø 60Hz, 200V 3Ø 60Hz
PF3007 High Head Effluent Pump
30 GPM, 3/4HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF3010 High Head Effluent Pump
30 GPM, 1HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF3015 High Head Effluent Pump
30 GPM, 1-1/2HP
230V 1Ø 60Hz, 200/230/460V 3Ø 60Hz
Legend
System Curve:
Pump Curve:
Pump Optimal Range:
Operating Point:
Design Point:
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 1 of 4
Biotube® ProPak Pump Package™
Technical Data SheetOrenco®
60-Hz Series Pump Packages General
Orenco’s Biotube® ProPak™ is a complete, integrated pump package for
filtering and pumping effluent from septic tanks. And its patented pump
vault technology eliminates the need for separate dosing tanks.
This document provides detailed information on the ProPak pump vault
and filter, 4-in. (100-mm) 60-Hz turbine effluent pump, and control panel.
For more information on other ProPak components, see the following
Orenco technical documents:
• Float Switch Assemblies (NSU-MF-MF-1)
• Discharge Assemblies (NTD-HV-HV-1)
• Splice Boxes (NTD-SB-SB-1)
• External Splice Box (NTD-SB-SB-1)
Applications
The Biotube ProPak is designed to filter and pump effluent to either
gravity or pressurized discharge points. It is intended for use in a septic
tank (one- or two-compartment) and can also be used in a pump tank.
The Biotube ProPak is designed to allow the effluent filter to be removed
for cleaning without the need to remove the pump vault or pump, simpli-
fying servicing.
Complete packages are available for on-demand or timed dosing sys-
tems with flow rates of 20, 30, and 50-gpm (1.3, 1.9, and 3.2 L/sec),
as well as with 50 Hz and 60 Hz power supplies.
Standard Models
BPP20DD, BPP20DD-SX, BPP30TDA, BPP30TDD-SX, BBPP50TDA,
BPP50TDD-SX
Product Code Diagram
Biotube® ProPak™ pump package components.
4-in. (100-mm)
turbine effluent pump
Pump motor
Pump
liquid end
Pump vault
Support pipe
Discharge
assembly
Float collar
Float stem
Floats
Float
bracket
Biotube® filter
cartridge
Vault inlet holes
External splice box
(Optional; internal splice
box comes standard.)
Riser lid
(not included)
Riser (not
included)
Control panel
BPP
Pump flow rate, nominal:
20 = 20 gpm (1.3 L/sec)
30 = 30 gpm (1.9 L/sec)
50 = 50 gpm (3.2 L/sec)
Control panel application:
DD = demand-dosing
TDA = timed-dosing, analog timer
TDD = timed dosing, digital timer, elapsed time
meter & counters
Standard options:
Blank = 57-in. (1448-mm) vault height, internal
splice box, standard discharge assembly
68 = 68-in. (1727-mm) vault height
SX = external splice box
CW = cold weather discharge assembly
DB = drainback discharge assembly
Q = cam lock
MFV = non-mercury float
-
Biotube® ProPak™ pump vault
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 2 of 4
ProPak™ Pump Vault
Materials of Construction
Vault body Polyethylene
Support pipes PVC
Dimensions, in. (mm)
A - Overall vault height 57 (1448) or 68 (1727)
B - Vault diameter 17.3 (439)
C - Inlet hole height 19 (475)
D - Inlet hole diameter (eight holes total) 2 (50)
E - Vault top to support pipe bracket base 3 (76)
F - Vault bottom to filter cartridge base 4 (102)
ProPak™ pump vault (shown with Biotube filter and effluent pump)
Biotube® Filter Cartridge
Materials of Construction
Filter tubes Polyethylene
Cartridge end plates Polyurethane
Handle assembly PVC
Dimensions, in. (mm)
A - Cartridge height 18 (457)
B - Cartridge width 12 (305)
Performance
Biotube® mesh opening 0.125 in. (3 mm)*
Total filter flow area 4.4 ft2 (0.4 m2)
Total filter surface area 14.5 ft2 (1.35 m2)
Maximum flow rate 140 gpm (8.8 L/sec)
*0.062-in. (1.6-mm) filter mesh available
Biotube® filter cartridge (shown with float switch assembly)
AA
D
E
B B
C
E
Technical Data Sheet Orenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 3 of 4
Pump Curves
Pump curves, such as those shown here, can help you determine
the best pump for your system. Pump curves show the relationship
between flow (gpm or L/sec) and pressure (TDH), providing a graphical
representation of a pump’s performance range. Pumps perform best
at their nominal flow rate, measured in gpm or L/sec.
4-in. (100-mm) Turbine Effluent Pumps
Orenco’s 4-in. (100 mm) Turbine Effluent Pumps are constructed of
lightweight, corrosion-resistant stainless steel and engineered plastics;
all are field-serviceable and repairable with common tools. All 60-Hz
PF Series models are CSA certified to the U.S. and Canadian safety
standards for effluent pumps, and meet UL requirements.
Power cords for Orenco’s 4-in. (100-mm) turbine effluent pumps are
Type SOOW 600-V motor cable (suitable for Class 1, Division 1 and 2
applications).
Materials of Construction
Discharge: Stainless steel or glass-filled polypropylene
Discharge bearing: Engineered thermoplastic (PEEK)
Diffusers: Glass-filled PPO
Impellers: Acetal (20-, 30-gmp), Noryl (50-gpm)
Intake screens: Polypropylene
Suction connection: Stainless steel
Drive shaft: 300 series stainless steel
Coupling: Sintered 300 series stainless steel
Shell: 300 series stainless steel
Lubricant: Deionized water and propylene glycol
Specifications
Nom. flow, Length Weight Discharge Impellers
gpm (L/sec) in. (mm) lb (kg) in., nominal 1
20 (1.3) 22.5 (572) 26 (11) 1.25 4
30 (1.9) 21.3 (541) 25 (11) 1.25 3
50 (3.2) 20.3 (516) 27 (12) 2.00 2
Performance
Nom. flow, hp (kW) Design Rated Min liquid
gpm (L/sec) flow amps cycles/day level, in. (mm) 2
20 (1.3) 0.5 (0.37) 12.3 300 18 (457)
30 (1.9) 0.5 (0.37) 11.8 300 20 (508)
50 (3.2) 0.5 (0.37) 12.1 300 24 (610)
1 Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® discharge
hose and valve assemblies. Consult your Orenco Distributor about fittings to connect discharge
assemblies to metric-sized piping.
2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® ProPak™ Pump
Vault.
10 20 30 40 6050 70
0.63 1.26 1.89 2.52 3.793.15 4.42
140
120
100
80
60
40
20
Flow in gallons per minute (gpm)
Flow in liters per second (L/sec)Total dynamic head (TDH) in feetTotal dynamic head (TDH) in metersPF 500511
43
37
30
24
18
12
6
PF 200511
PF 300511
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 4 of 4
AUTO
OFF
MAN
NN1
Control Panel (Demand Dose)
Orenco’s ProPak™ demand dose control panels are specifically engineered
for the ProPak pump package and are ideal for applications such as
demand dosing from a septic tank into a conventional gravity drainfield.
Materials of Construction
Enclosure UV-resistant fiberglass, UL Type 4X
Hinges Stainless steel
Dimensions, in. (mm)
A - Height 11.5 (290)
B - Width 9.5 (240)
C - Depth 5.4 (135)
Specifications
Panel ratings 120 V, 3/4 hp (0.56 kW), 14 A, single phase, 60 Hz
1. Motor-start contactor 16 FLA, 1 hp (0.75 kW), 60 Hz; 2.5 million cycles
at FLA (10 million at 50% of FLA)
2. Circuit 120 V, 10 A, OFF/ON switch, Single pole breakers
3. Toggle switch Single-pole, double-throw HOA switch, 20 A
4. Audio alarm 95 dB at 24 in. (600 mm), warble-tone sound, UL
Type 4X
5. Audio alarm 120 V, automatic reset, DIN rail mount silence
relay
6. Visual alarm 7/8-in. (22-mm) diameter red lens, “Push-to-silence,”
120 V LED, UL Type 4X
Control Panel (Timed Dose)
Orenco’s ProPak timed dose control panels are specifically engineered for
the ProPak pump package and are ideal for applications such as timed
dosing from a septic tank into a pressurized drainfield or mound. Analog or
digital timers are available.
Materials of Construction
Enclosure UV-resistant fiberglass, UL Type 4X
Hinges Stainless steel
Dimensions, in. (mm)
A - Height 11.5 (290)
B - Width 9.5 (240)
C - Depth 5.4 (135)
Specifications
Panel ratings 120 V, 3/4 hp (0.56 kW), 14 A, single phase, 60 Hz
Dual-mode Programmable for timed- or demand-dosing
(digital timed-dosing panels only)
1a. Analog timer 120 V, repeat cycle from 0.05 seconds to 30
(not shown) hours. Separate variable controls for OFF and
ON time periods
1b. Digital timer 120-V programmable logic unit with built-in LCD
(shown below) screen and programming keys. Provides control
functions and timing for panel operation
2. Motor-start contactor 16 FLA, 1 hp (0.75 kW), 60 Hz; 2.5 million cycles
at FLA (10 million at 50% of FLA)
3. Circuit breakers 120 V, 10 A, OFF/ON switch. Single pole 120 V
4. Toggle Switch Single-pole, double-throw HOA switch, 20 A
5. Audio alarm 95 dB at 24 in. (600 mm), warble-tone sound, UL
Type 4X
6. Visual alarm 7/8-in. (22-mm) diameter red lens, “Push-to-silence”,
120 V LED, UL Type 4X
Control panel, demand-dose Control panel, timed-dose (digital timer model shown)
1b
2
3
4
56
1
2
3
4
5
6
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 1 of 6
PF Series 4-inch (100-mm) Submersible Effluent Pumps
Technical Data SheetOrenco®
Applications
Our 4-inch (100-mm) Submersible Effluent Pumps are designed to
transport screened effluent (with low TSS counts) from septic tanks or
separate dosing tanks. All our pumps are constructed of lightweight,
corrosion-resistant stainless steel and engineered plastics; all are field-
serviceable and repairable with common tools; and all 60-Hz PF Series
models are CSA certified to the U.S. and Canadian safety standards for
effluent pumps, meeting UL requirements.
Orenco’s Effluent Pumps are used in a variety of applications, including
pressurized drainfields, packed bed filters, mounds, aerobic units, effluent
irrigation, effluent sewers, wetlands, lagoons, and more. These pumps
are designed to be used with a Biotube® pump vault or after a secondary
treatment system.
Features/Specifications
To specify this pump for your installation, require the following:
• Minimum 24-hour run-dry capability with no deterioration in pump life
or performance*
• Patented 1⁄8-inch (3-mm) bypass orifice to ensure flow recirculation
for motor cooling and to prevent air bind
• Liquid end repair kits available for better long-term cost of ownership
• TRI-SEAL™ floating impeller design on 10, 15, 20, and 30 gpm
(0.6, 1.0, 1.3, and 1.9 L/sec) models; floating stack design on 50 and
75 gpm (3.2 and 4.7 L/sec) models
• Franklin Electric Super Stainless motor, rated for continuous use and
frequent cycling
• Type SOOW 600-V motor cable
• Five-year warranty on pump or retrofit liquid end from date of manu-
facture against defects in materials or workmanship
* Not applicable for 5-hp (3.73 kW) models
Standard Models
See specifications chart, pages 2-3, for a list of standard pumps. For
a complete list of available pumps, call Orenco.
Product Code Diagram
PF -
Nominal flow, gpm (L/sec):
10 = 10 (0.6) 15 = 15 (1.0)
20 = 20 (1.3) 30 = 30 (1.9)
50 = 50 (3.2) 75 = 75 (4.7)
Pump, PF Series
Frequency:
1 = single-phase 60 Hz
3 = three-phase 60 Hz
5 = single-phase 50 Hz
Voltage, nameplate:
1 = 115* 200 = 200
2 = 230† 4 = 460
Horsepower (kW):
03 = 1⁄3 hp (0.25) 05 = ½ hp (0.37)
07 = ¾ hp (0.56) 10 = 1 hp (0.75)
15 = 1-½ hp (1.11) 20 = 2 hp (1.50)
30 = 3 hp (2.24) 50 = 5 hp (3.73)
Cord length, ft (m):‡
Blank = 10 (3) 20 = 20 (6)
30 = 30 (9) 50 = 50 (15)
* ½-hp (0.37kW) only
†220 volts for 50 Hz pumps
‡Note: 20-foot cords are available only for single-phase pumps through 1-½ hp
Franklin
Super Stainless
Motor
Franklin
Liquid End
Discharge Connection
Bypass Orifice
Suction Connection
LR80980
LR2053896
Powered by
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 2 of 6
Specifications, 60 Hz
Pump Model
PF100511 10 (0.6) 0.50 (0.37) 1 115 120 12.7 12.7 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF100512 10 (0.6) 0.50 (0.37) 1 230 240 6.3 6.3 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF10053200 10 (0.6) 0.50 (0.37) 3 200 208 3.8 3.8 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF100712 4, 5 10 (0.6) 0.75 (0.56) 1 230 240 8.3 8.3 8 1 ¼ in. GFP 25.9 (658) 17 (432) 30 (14) 300
PF10073200 4, 5 10 (0.6) 0.75 (0.56) 3 200 208 5.1 5.2 8 1 ¼ in. GFP 25.4 (645) 17 (432) 31 (14) 300
PF101012 5, 6 10 (0.6) 1.00 (0.75) 1 230 240 9.6 9.6 9 1 ¼ in. GFP 27.9 (709) 18 (457) 33 (15) 100
PF10103200 5, 6 10 (0.6) 1.00 (0.75) 3 200 208 5.5 5.5 9 1 ¼ in. GFP 27.3 (693) 18 (457) 37 (17) 300
PF102012 5, 6, 7, 8 10 (0.6) 2.00 (1.49) 1 230 240 12.1 12.1 18 1 ¼ in. SS 39.5 (1003) 22 (559) 48 (22) 100
PF102032 5, 6, 8 10 (0.6) 2.00 (1.49) 3 230 240 7.5 7.6 18 1 ¼ in. SS 37.9 (963) 20 (508) 44 (20) 300
PF10203200 5, 6, 8 10 (0.6) 2.00 (1.49) 3 200 208 8.7 8.7 18 1 ¼ in. SS 37.9 (963) 20 (508) 44 (20) 300
PF150311 15 (1.0) 0.33 (0.25) 1 115 120 8.7 8.8 3 1 ¼ in. GFP 19.5 (495) 15 (380) 23 (10) 300
PF150312 15 (1.0) 0.33 (0.25) 1 230 240 4.4 4.5 3 1 ¼ in. GFP 19.5 (495) 15 (380) 23 (10) 300
PF200511 20 (1.3) 0.50 (0.37) 1 115 120 12.3 12.5 4 1 ¼ in. GFP 22.3 (566) 18 (457) 25 (11) 300
PF200512 20 (1.3) 0.50 (0.37) 1 230 240 6.4 6.5 4 1 ¼ in. GFP 22.5 (572) 18 (457) 26 (12) 300
PF20053200 20 (1.3) 0.50 (0.37) 3 200 208 3.7 3.8 4 1 ¼ in. GFP 22.3 (566) 18 (457) 26 (12) 300
PF201012 4, 5 20 (1.3) 1.00 (0.75) 1 230 240 10.5 10.5 7 1 ¼ in. GFP 28.4 (721) 20 (508) 33 (15) 100
PF20103200 4, 5 20 (1.3) 1.00 (0.75) 3 200 208 5.8 5.9 7 1 ¼ in. GFP 27.8 (706) 20 (508) 33 (15) 300
PF201512 4, 5 20 (1.3) 1.50 (1.11) 1 230 240 12.4 12.6 9 1 ¼ in. GFP 34.0 (864) 24 (610) 41 (19) 100
PF20153200 4, 5 20 (1.3) 1.50 (1.11) 3 200 208 7.1 7.2 9 1 ¼ in. GFP 30.7 (780) 20 (508) 35 (16) 300
PF300511 30 (1.9) 0.50 (0.37) 1 115 120 11.8 11.8 3 1 ¼ in. GFP 21.3 (541) 20 (508) 28 (13) 300
PF300512 30 (1.9) 0.50 (0.37) 1 230 240 6.2 6.2 3 1 ¼ in. GFP 21.3 (541) 20 (508) 25 (11) 300
PF30053200 30 (1.9) 0.50 (0.37) 3 200 208 3.6 3.6 3 1 ¼ in. GFP 21.3 (541) 20 (508) 25 (11) 300
PF300712 30 (1.9) 0.75 (0.56) 1 230 240 8.5 8.5 5 1 ¼ in. GFP 24.8 (630) 21 (533) 29 (13) 300
PF30073200 30 (1.9) 0.75 (0.56) 3 200 208 4.9 4.9 5 1 ¼ in. GFP 24.6 (625) 21 (533) 30 (14) 300
PF301012 4 30 (1.9) 1.00 (0.75) 1 230 240 10.4 10.4 6 1 ¼ in. GFP 27.0 (686) 22 (559) 32 (15) 100
PF30103200 4 30 (1.9) 1.00 (0.75) 3 200 208 5.8 5.8 6 1 ¼ in. GFP 26.4 (671) 22 (559) 33 (15) 300
PF301512 4, 5 30 (1.9) 1.50 (1.11) 1 230 240 12.6 12.6 8 1 ¼ in. GFP 32.8 (833) 24 (610) 40 (18) 100
PF30153200 4, 5 30 (1.9) 1.50 (1.11) 3 200 208 6.9 6.9 8 1 ¼ in. GFP 29.8 (757) 22 (559) 34 (15) 300
PF301534 4, 5 30 (1.9) 1.50 (1.11) 3 460 480 2.8 2.8 8 1 ¼ in. GFP 29.5 (685) 22 (559) 34 (15) 300
PF302012 5, 6, 7 30 (1.9) 2.00 (1.49) 1 230 240 11.0 11.0 10 1 ¼ in. SS 35.5 (902) 26 (660) 44 (20) 100
PF30203200 5, 6 30 (1.9) 2.00 (1.49) 3 200 208 9.3 9.3 10 1 ¼ in. SS 34.0 (864) 24 (610) 41 (19) 300
PF303012 5, 6, 7, 8 30 (1.9) 3.00 (2.23) 1 230 240 16.8 16.8 14 1 ¼ in. SS 44.5 (1130) 33 (838) 54 (24) 100
PF303032 5, 6, 8 30 (1.9) 3.00 (2.23) 3 230 240 10.0 10.1 14 1 ¼ in. SS 44.3 (1125) 27 (686) 52 (24) 300
PF305012 5, 6, 7, 8 30 (1.9) 5.00 (3.73) 1 230 240 25.6 25.8 23 1 ¼ in. SS 66.5 (1689) 53 (1346) 82 (37) 100
PF305032 5, 6, 8 30 (1.9) 5.00 (3.73) 3 230 240 16.6 16.6 23 1 ¼ in. SS 60.8 (1544) 48 (1219) 66 (30) 300
PF30503200 5, 6, 8 30 (1.9) 5.00 (3.73) 3 200 208 18.7 18.7 23 1 ¼ in. SS 60.8 (1544) 48 (1219) 66 (30) 300
PF500511 50 (3.2) 0.50 (0.37) 1 115 120 12.1 12.1 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300
PF500512 50 (3.2) 0.50 (0.37) 1 230 240 6.2 6.2 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300
PF500532 50 (3.2) 0.50 (0.37) 3 230 240 3.0 3.0 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
PF50053200 50 (3.2) 0.50 (0.37) 3 200 208 3.7 3.7 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
PF500534 50 (3.2) 0.50 (0.37) 3 460 480 1.5 1.5 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
PF500712 50 (3.2) 0.75 (0.56) 1 230 240 8.5 8.5 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300
PF500732 50 (3.2) 0.75 (0.56) 3 230 240 3.9 3.9 3 2 in. SS 23.7 (602) 25 (635) 32 (15) 300
PF50073200 50 (3.2) 0.75 (0.56) 3 200 208 4.9 4.9 3 2 in. SS 23.1 (587) 26 (660) 32 (15) 300Design gpm (L/sec)Horsepower (kW)PhaseNameplate voltageActual voltageDesign flow ampsMax ampsImpellersDischarge size and material 1Length, in. (mm)Min. liquid level, 2 in. (mm)Weight, 3 lb (kg)Rated cycles/day
Technical Data Sheet Orenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 3 of 6
Specifications, 60 Hz (continued)
Pump Model
PF500734 50 (3.2) 0.75 (0.56) 3 460 480 1.8 1.8 3 2 in. SS 34.8 (884) 25 (635) 31 (14) 300
PF501012 50 (3.2) 1.00 (0.75) 1 230 240 10.1 10.1 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100
PF50103200 50 (3.2) 1.00 (0.75) 3 200 208 5.7 5.7 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300
PF501034 50 (3.2) 1.00 (0.75) 3 460 480 2.2 2.2 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300
PF5015124 50 (3.2) 1.50 (1.11) 1 230 240 12.5 12.6 5 2 in. SS 32.5 (826) 30 (762) 41 (19) 100
PF501532004 50 (3.2) 1.50 (1.11) 3 200 208 7.0 7.0 5 2 in. SS 29.3 (744) 26 (660) 35 (16) 300
PF503012 4, 5, 7, 8 50 (3.2) 3.00 (2.23) 1 230 240 17.7 17.7 8 2 in. SS 43.0 (1092) 37 (940) 55 (25) 100
PF50303200 4, 5, 8 50 (3.2) 3.00 (2.23) 3 200 208 13.1 13.1 8 2 in. SS 43.4 (1102) 30 (762) 55 (25) 300
PF503034 4, 5, 8 50 (3.2) 3.00 (2.23) 3 460 480 5.3 5.3 8 2 in. SS 40.0 (1016) 31 (787) 55 (25) 300
PF505012 5,6,7,8 50 (3.2) 5.00 (3.73) 1 230 240 26.2 26.4 13 2 in. SS 65.4 (1661) 55 (1397) 64 (29) 300
PF505032 5,6,7,8 50 (3.2) 5.00 (3.73) 3 230 240 16.5 16.5 13 2 in. SS 59.3 (1506) 49 (1245) 64 (29) 300
PF751012 75 (4.7) 1.00 (0.75) 1 230 240 9.9 10.0 3 2 in. SS 27.0 (686) 27 (686) 34 (15) 100
PF751512 75 (4.7) 1.50 (1.11) 1 230 240 12.1 12.3 4 2 in. SS 33.4 (848) 30 (762) 44 (20) 100
Specifications, 50 Hz
Pump Model
PF100552 10 (0.6) 0.50 (0.37) 1 220 230 3.9 4.1 6 1 ¼ in. GFP 23.0 (584) 17 (432) 26 (12) 300
PF100752 4, 5 10 (0.6) 0.75 (0.56) 1 220 230 6.2 6.2 9 1 ¼ in. GFP 26.8 (658) 17 (432) 30 (14) 300
PF101552 5, 6 10 (0.6) 1.50 (1.11) 1 220 230 10.5 11.4 18 1 ¼ in. SS 39.5 (1003) 22 (559) 46 (21) 300
PF300552 30 (1.9) 0.50 (0.37) 1 220 230 4.1 4.1 4 1 ¼ in. GFP 22.5 (572) 19 (483) 26 (12) 300
PF300752 30 (1.9) 0.75 (0.56) 1 220 230 6.1 6.1 5 1 ¼ in. GFP 24.8 (630) 19 (483) 29 (13) 300
PF301052 30 (1.9) 1.00 (0.75) 1 220 230 7.4 7.4 7 1 ¼ in. GFP 28.4 (721) 20 (508) 32 (15) 100
PF301552 4, 5 30 (1.9) 1.50 (1.11) 1 220 230 9.3 9.3 8 1 ¼ in. GFP 35.4 (899) 24 (610) 40 (18) 100
PF500552 50 (3.2) 0.50 (0.37) 1 220 230 4.0 4.0 2 2 in. SS 20.3 (516) 25 (635) 29 (13) 300
PF500752 50 (3.2) 0.75 (0.56) 1 220 230 6.3 6.4 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300
PF501052 50 (3.2) 1.00 (0.75) 1 220 230 7.3 7.4 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100
PF501552 50 (3.2) 1.50 (1.11) 1 220 230 9.1 9.1 5 2 in. SS 32.5 (826) 30 (762) 42 (19) 100
PF751052 75 (3.2) 1.00 (0.75) 1 220 230 7.3 7.3 4 2 in. SS 30.0 (762) 27 (686) 34 (15) 100
1 GFP = glass-filled polypropylene; SS = stainless steel. The 1 ¼-in. NPT GFP discharge is 2 7⁄8 in. octagonal across flats; the 1 ¼-in. NPT SS discharge is 2 1⁄8 in. octagonal across flats; and the
2-in. NPT SS discharge is 2 7⁄8 in. hexagonal across flats. Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® discharge hose and valve assemblies. Consult your Orenco
Distributor about fittings to connect hose and valve assemblies to metric-sized piping.
2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® Pump Vault or Universal Flow Inducer. In other applications, minimum liquid level should be top of pump. Consult
Orenco for more information.
3 Weight includes carton and 10-ft (3-m) cord.
4 High-pressure discharge assembly required.
5 Do not use cam-lock option (Q) on discharge assembly.
6 Custom discharge assembly required for these pumps. Contact Orenco.
7 Capacitor pack (sold separately or installed in a custom control panel) required for this pump. Contact Orenco.
8 Torque locks are available for all pumps, and are supplied with 3-hp and 5-hp pumps. Design gpm (L/sec)Horsepower (kW)PhaseNameplate voltageActual voltageDesign flow ampsMax ampsImpellersDischarge size and material 1Length, in. (mm)Min. liquid level, 2 in. (mm)Weight, 3 lb (kg)Rated cycles/day
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 4 of 6
Materials of Construction
Discharge Glass-filled polypropylene or stainless steel
Discharge bearing Engineered thermoplastic (PEEK)
Diffusers Glass-filled PPO (Noryl GFN3)
Impellers Celcon® acetal copolymer on 10-, 20, and 30-gpm models; 50-gpm impellers are Noryl GFN3
Intake screen Polypropylene
Suction connection Stainless steel
Drive shaft 7/16 inch hexagonal stainless steel, 300 series
Coupling Sintered stainless steel, 300 series
Shell Stainless steel, 300 series
Motor Franklin motor exterior constructed of stainless steel. Motor filled with deionized water and propylene glycol for constant lubrication. Hermetically
sealed motor housing ensures moisture-free windings. All thrust absorbed by Kingsbury-type thrust bearing. Rated for continuous duty. Single-
phase motors and 200 and 230 V 3-phase motors equipped with surge arrestors for added security. Single-phase motors through 1.5 hp
(1.11 kW) have built-in thermal overload protection, which trips at 203-221˚ F (95-105˚ C).
Using a Pump Curve
A pump curve helps you determine the best pump for your system. Pump curves show the relationship between flow (gpm or L/sec) and pressure
(total dynamic head, or TDH), providing a graphical representation of a pump’s optimal performance range. Pumps perform best at their nominal
flow rate — the value, measured in gpm, expressed by the first two numerals in an Orenco pump nomenclature. The graphs in this section show
optimal pump operation ranges with a solid line. Flow flow rates outside of these ranges are shown with a dashed line. For the most accurate
pump specification, use Orenco’s PumpSelect™ software.
Pump Curves, 60 Hz Models
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
24 81012141660
800
700
600
500
400
300
200
100 PF1005-FC
w/ ¼" flow
controller
PF10 Series, 60 Hz, 0.5 - 2.0 hp
PF1007
PF1010
PF1020
PF1005
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
36 12 15 18 21 2490
160
140
120
100
80
60
40
20
0
PF1503
PF15 Series, 60 Hz, 0.3 hp
Technical Data Sheet Orenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 5 of 6Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
5102025303540150
400
350
300
250
200
150
100
50
0
PF2005
PF2010
PF2015
PF20 Series, 60 Hz, 0.5 - 1.5 hp
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
510202530354045150
800
900
700
600
500
400
300
200
100
0
PF3005
PF3007
PF3010
PF3015
PF3020
PF3030
PF3050 PF30 Series, 60 Hz, 0.5 - 5.0 hp
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
450
400
350
300
250
200
150
100
50
0 10 02040506070809030
PF5050
PF5030
PF5015
PF5010
PF5007
PF5005
PF50 Series, 60 Hz, 0.5 - 5.0 hp
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
10 20 40 50 60 70 80 90 100300
80
90
100
70
60
50
40
30
20
10
0
PF75 Series, 60 Hz, 1.0 - 1.5 hpPF7515
PF7510
60 Hz Models (continued)
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 6 of 6Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.90.80.70.60.50.40.30.20.10
13119.57.96.34.83.21.6
120
100
80
60
40
20
0
160
180
140
394
328
262
197
131
66
525
459
PF100552
PF100752
PF101552
PF1005-FC
w/ 6mm flow
controller
PF10 Series, 50 Hz, 0.37 - 1.11 kW
Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.8 1.2 1.6 2.0 2.40.40
13 19 25 326.3
60
80
100
120
40
20
0
197
262
328
131
66
PF301552
PF301052
PF300752
PF300552
PF30 Series, 50 Hz, 0.37 - 1.11 kW
Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.5 1.0 2.0 2.5 3.0 3.5 4.0 4.51.50
7.9 16 32 40 48 56 6324
40
45
35
30
25
20
15
10
5
0
131
115
98
82
66
49
33
16
PF501552
PF501052
PF500752
PF500552
PF50 Series, 50 Hz, 0.37 - 1.11 kW
Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.6 1.2 2.4 3.0 3.6 4.2 5.44.8 6.01.80
10 19 4838 57 67 76 8629
27
30
24
21
18
15
12
9
6
3
0
89
79
69
59
49
39
30
20
PF751052
PF75 Series, 50 Hz, 0.75 kW
Pump Curves, 50 Hz Models
Introduction
Orenco’s automatic distributing valve assemblies, pressurized with small high-head effluent
pumps, are useful for distributing effluent to multiple zones. These zones can be segments
of sand filter manifolds, drainfields, or other effluent distribution systems. Distributing
valve assemblies can substantially simplify the design and installation of a distribution sys-
tem and reduce installation costs. This is particularly true where a distributing valve assem-
bly is used instead of multiple pumps and/or electrically operated valves. Additionally, a
reduction in long term operation and maintenance costs is realized due to a reduced size
and/or number of pumps. More even distribution can be achieved on sloping sites by zoning
laterals at equal elevations. This eliminates drainback to lower lines and the unequal distrib-
ution of effluent that occurs at the beginning of a cycle.
Valve Operation
The valve itself has only a few moving parts, requires no electricity, and alternates automati-
cally each cycle. Refer to Figure 1 for the following valve operation description. The flow
of the incoming effluent forces the rubber flap disk 1 to seat against the valve bottom 2.
The opening 3 in the rubber flap disk aligns with an opening in the valve bottom to allow
flow to only one valve outlet. The stem 4 houses a stainless steel spring which pushes the
rubber flap disk away from the valve bottom after the flow of effluent stops. The stem acts
as a cam follower and rotates the rubber flap disk as the stem is raised and lowered through
the cam 5. The force from the flow of effluent pushes the stem down through the cam and
the stainless steel spring pushes the stem back up through the cam when the flow of effluent
stops. Each linear motion of the stem allows the rubber flap disk to rotate half the distance
necessary to reach the next outlet. When there is no flow, the rubber flap disk is in the “up”
position and is not seated against the valve bottom.
5
4
3
2
1
Inlet
Outlets
Figure 1:
6000 Series Valve
Orenco Automatic Distributing
Valve Assemblies
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 1 of 6
For Wastewater Effluent Systems
This article may describe design criteria that was in effect at the time the article was written. FOR CURRENT DESIGN
CRITERIA, call Orenco Systems, Inc. at 1-800-348-9843.
The Distributing Valve Assembly
The Orenco Automatic Distributing Valve Assembly combines the distributing valve itself and sever-
al other components to give a complete preassembled unit that is easy to install, monitor, and main-
tain. Figure 2 shows a complete assembly. Because distributing valves with several outlets can be
difficult to line up and glue together in the field, the discharge lines in the assemblies are glued in
place at Orenco. The unions (1) allow removal and maintenance of the valve. The clear PVC pipe
sections (2) give a visual check of which discharge line is being pressurized. The inlet ball valve (3)
allows a quick, simple method to test for proper valve cycling. The ball valve also stops the flow of
effluent in case the pump is activated unexpectedly during maintenance or inspection. Check valves
may be necessary on the discharge lines. Use of check valves is discussed in the valve positioning
section.
Valve Assembly Hydraulics
Liquid flowing through the valve assembly must pass through fairly small openings and make several
changes in direction. Because of this, headlosses through the valve assembly are fairly high. Table 1
gives the headloss equations for several different assemblies and Figure 3 shows the graphical repre-
sentations of these equations. Orenco recommends that high-head turbine pumps be used to pressur-
ize the valve assemblies to ensure enough head is available for proper system operation. High-head
turbine pumps are also recommended because the use of a distributing valve usually requires more
frequent pump cycling. The high-head turbine pumps are designed for high cycling systems and will
outlast conventional effluent pumps by a factor of 10 or more in a high cycling mode. Furthermore,
the high-head turbine pump intake is 12 inches or more above the bottom of the pump and tends to
prevent any settled solids from being pumped into the distribution valve and obstructing its opera-
tion. A minimum flow rate through the distributing valve is required to ensure proper seating of the
rubber flap disk. Minimum flow rates for the various models are given in Table 1.
Figure 2:
Orenco Distributing Valve Assembly (6000 Series Valve)
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 2 of 6
Table 1. Automatic Distributing Valve Assembly Headloss Equations
Model Series Equation Operating Range (gpm)
V4400A HL = 0.085 x Q1.45 10 - 40
V4600A HL = 0.085 x Q1.58 10 - 25
V6400A HL = 0.0045 x Q2 + 3.5 x (1 - e-0.06Q) 15 - 70
V6600A HL = 0.0049 x Q2 + 5.5 x (1 - e-0.1Q) 15 - 70
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 3 of 6
0
5
10
15
20
25
30
35
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
Flow (gpm)Head Loss Through Assembly (ft.)V4600A
V4400A
V6600A
V6400A
The Pumping System
Although the distributing valve was designed for the irrigation industry, it has started to gain fairly
wide acceptance in the effluent pumping industry. However, because of the mechanical movements
of the valve, it is necessary to take steps to prevent solids from reaching the distributing valve that
may impede the operation of the valve. Orenco Biotube®Pump Vaults — when properly sized and
installed — provide the necessary protection to prevent valve malfunction. The Biotube®pump vault
accepts effluent only from the clear zone between a tank’s scum and sludge layers and then filters
this effluent through a very large surface area screen cartridge. Without this protection in effluent
systems, the valve has very little chance of reliable long-term operation.
Figure 3:
Automatic distributing valve assembly headloss curves
Valve Positioning
The physical position of the valve in relation to the pump and the discharge point is very important
for proper valve operation. The most reliable operation occurs when the valve is placed at the high
point in the system and as close to the pump as possible. The transport line between the pump and
valve should be kept full if possible. If the line is empty at the beginning of each cycle, pockets of
air during filling can cause random rotation of the valve. The valve is particularly vulnerable to this
erratic rotation with empty lines that are long and not laid at a constant grade. An ideal valve loca-
tion is shown in Figure 4.
If the final discharge point is more than about 2 feet above the valve and the system does not drain
back into the dosing tank, check valves should be installed on the lines immediately following the
valve and a pressure release hole or line should be installed just prior to the valve. This pressure
release hole or line can go into a return line to the dosing tank or to a “minidrainfield” near the valve.
In order for the valve to rotate reliably, no more than about 2 feet of head should remain against the
valve to allow the rubber flap disk to return to its up position. In many cases, it may take from one
minute to several minutes for the pressure in the valve to be lowered enough for proper rotation to
occur. Special care should be taken when installing systems controlled by programmable timers to
ensure cycling does not occur too rapidly. Figure 5 illustrates a valve assembly using check valves.
Pumping downhill to the valve should be avoided unless the transport line is very short and the ele-
vation between the discharge line out of the tank and the valve is less than about 2 feet. If the valve
is located many feet below the dosing tank, random cycling may occur while the transport line drains
through the valve at the end of the cycle. A pressure sustaining valve located just before the distrib-
uting valve may overcome this problem in some instances.
Dosing Tank
Discharge Laterals
Distributing Valve Assembly
Transport Line
Figure 4:
Ideal valve location
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 4 of 6
System Startup
Refer to the Hydrotek Valve booklet that is provided with the distributing valve assembly for the
sequencing of the valve outlets. The transport line should always be flushed with clean water before
installing the valve. Any sand, gravel, or other foreign objects that may have been in the pipe during
installation can easily become lodged in the distributing valve, causing malfunction.
With the pump running, alternately close and open the ball valve on the distributing valve assembly
to check proper rotation of the valve. (Note: If check valves are used on the lines after the distribut-
ing valve, the pump may need to be turned on and off to allow the pressure to be released from the
valve.) If visual operation of which zone is operating is not possible, watch the clear pipe on each
line for indication of which zone is operating.
Maintenance
Annually check for proper operation by following procedures listed in the Hydrotek Valve booklet
and system startup procedures listed above.
Troubleshooting
1. PROBLEM: Valve does not change or cycle to next zone or outlet
CAUSE: The stem and disk assembly is not rotating when water flow is turned off and then
back on.
SOLUTION 1: Ensure that there is no debris inside the cam. Clean and carefully reinstall the cam.
SOLUTION 2: If fewer than the maximum number of outlets are being used, check the installation
of the cam. Ensure that the stem and disk assembly is not being held down by an
improperly installed cam. Refer to the cam replacement instructions.
h
Check Valves if h>2'-0"
Distributing Valve Assembly
Transport Line
Dosing Tank
Pressure Release
Line if h>2'-0"
Discharge Laterals
Figure 5:
Valve assembly below final discharge point
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 5 of 6
SOLUTION 3: Remove the valve top and check for proper movement of stem and disk assembly.
Check for and remove any debris or foreign objects that may jam or retard the
movement of the disk.
SOLUTION 4: Check for freedom of movement of stem and disk assembly up and down over the
center pin in bottom of valve. Scale deposits may build up on the pin and hold stem
and disk assembly down. Clean pin and again check for freedom of movement.
SOLUTION 5: Be sure that all operating outlets are not capped and that the flow to operating zones
is not restricted in any manner. This would cause pressure to build up in the valve
and lock the stem and disk assembly in the down position.
SOLUTION 6: The backflow of water from uphill lines may be preventing the valve from cycling
properly. This can happen when the valve is placed too far below an elevated line.
If the valve cannot be placed close to the high point of the system, a check valve
should be installed near the valve in the outlet line that runs uphill from the valve
and a drain line installed just prior to the valve to relieve the pressure.
2. PROBLEM: Water comes out of all the valve outlets
CAUSE: Stem and disk assembly not seating properly on valve outlet.
SOLUTION 1: Check for sufficient water flow. A minimum flow rate is required to properly seat
the disk as shown in Table 1.
SOLUTION 2: Remove the valve top and check the inside walls to ensure that nothing is interfering
with the up and down movement of the stem and disk assembly inside the valve.
SOLUTION 3: Make sure that the operating outlets are not capped and that the flow to the operat-
ing zones are not restricted in any manner.
3. PROBLEM: Valve skips outlets or zones
CAUSE: Pumping into an empty transport line — especially downhill — may cause the valve
to skip outlets from pockets of air allowing the rubber flap disk to raise during a
cycle.
SOLUTION 1: Keep the transport line full.
SOLUTION 2: If the line must remain empty between cycles, use a larger diameter transport line
laid at a constant grade to prevent air pockets from forming.
CAUSE: The stem and disk assembly is being advanced past the desired outlet.
SOLUTION 1: Ensure that the correct cam for the desired number of zones is installed and that the
outlet lines are installed to the correct outlet ports of the valve as indicated by the
zone numbers on the top of the cam.
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 6 of 6
Distributing Valves
General
Orenco’s Automatic Distributing Valve Assemblies are
mechanically operated and sequentially redirect the
pump’s flow to multiple zones or cells in a distribution
field. Valve actuation is accomplished by a combination
of pressure and flow. Automatic Distributing Valve
Assemblies allow the use of smaller horsepower pumps
on large sand filters and drainfields. For example, a large
community drainfield requiring 300 gpm can use a six-line
Valve Assembly to reduce the pump flow rate requirement
to only 50 gpm.
Orenco only warrants Automatic Distributing Valves when
used in conjunction with High-Head Effluent Pumps with
Biotube®Pump Vaults to provide pressure and flow
requirements, and to prevent debris from fouling valve
operation. An inlet ball valve and a section of clear pipe
and union for each outlet are provided for a complete
assembly that is easy to maintain and monitor. Ideal
valve location is at the high point in the system. Refer to
Automatic Distributing Valve Assemblies (NTP-VA-1) for
more information.
Standard Models
V4402A, V4403A, V4404A, V4605A, V4606A, V6402A, V6403A,
V6404A, V6605A, V6606A.
Nomenclature
Submittal
Data Sheet
Side View
ball valve
elbow
Top View
coupling
clear pipe
distributing valve
union
Bottom View
elbows
Specifications
Materials of Construction
All Fittings: Sch. 40 PVC per ASTMspecification
Unions: Sch. 80 PVCper ASTMspecification
Ball Valve: Sch. 40 PVCper ASTMspecification
Clear Pipe: Sch. 40 PVCper ASTMspecification
V4XXX Distributing Valves: High-strength noncorrosive ABSpolymer and stainless steel
V6XXX Distributing Valves: High-strength noncorrosive ABSpolymer, stainless steel, and die cast metal
NSU-SF-VA-1
Rev. 3.0, © 4/03
Page 1 of 2
Applications
Automatic Distributing Valve Assemblies are used to pressurize
multiple zone distribution systems including textile filters, sand
filters and drainfields.
V
Indicates assembly
Model series:
44 = 4400 series (2-4 outlets)
46 = 4600 series (5-6 outlets)
64 = 6400 series (2-4 outlets)
66 = 6600 series (5-6 outlets)
Distributing valve
Number of active outlets
A
Distributing Valves (continued)
Flow (gpm)Head Loss Through Assembly (ft.)0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
0
5
10
15
20
25
30
35
V4400A
V6600A
V6400A
V4600A
NSU-SF-VA-1
Rev. 3.0, © 4/03
Page 2 of 2
Model Inlet Size (in.) Outlets Size (in.) Flow range (gpm) Max Head (ft.) Min. Enclosure
V4402A 1.25 1.25 10 - 40 170 VB1217
V4403A 1.25 1.25 10 - 40 170 VB1217
V4404A 1.25 1.25 10 - 40 170 VB1217
V4605A 1.25 1.25 10 - 25 170 RR2418
V4606A 1.25 1.25 10 - 25 170 RR2418
V6402A 1.5 1.5 15 - 100 345 RR2418
V6403A 1.5 1.5 15 - 100 345 RR2418
V6404A 1.5 1.5 15 - 100 345 RR2418
V6605A 1.5 1.5 15 - 100 345 RR2418
V6606A 1.5 1.5 15 - 100 345 RR2418
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-SF-OS-1
Rev. 1.1, © 09/14
Page 1 of 1
Orifice Shields
Technical Data SheetOrenco®
General
Orenco Orifice Shields snap-fit onto laterals. They may be placed on
top of or beneath a lateral, depending on the location of the orifice.
Orifice shields are covered by method-of-use patent # 5,360,556.
Standard Models
OS075, OS100, OS125, OS150, OS200
Product Code Diagram
Material of Construction
PVC per ASTM D-1784
Physical Specifications
Model Shield O.D. Lateral pipe O.D.
in. (mm) in. (mm)
OS075 3.5 (89) 1.05 (27)
OS100 3.5 (89) 1.315 (33)
OS125 3.5 (89) 1.66 (42)
OS150 4.5 (114) 1.90 (48)
OS200 4.5 (114) 2.375 (60)
Applications
Orenco® Orifice Shields are used in a pressurized distribution system
to protect the orifices from backfill debris that might cause orifice
blockage.
Orifice shield installed on lateral pipe, standard configuration
Shield
Orifice
Cutaway view, standard configuration
Shield
Orifice
Cutaway view, cold weather configuration
OS
Lateral pipe size, nominal:
075 = 0.75 in. (20 mm)
100 = 1.00 in. (25 mm)
125 = 1.25 in. (32 mm)
150 = 1.50 in. (40 mm)
200 = 2.00 in. (50 mm)
Orifice shield
NOT TO SCALE05/20/2015EMB1 of 1DFHDrawn by:Scale:Checked by:Sheet:Date:INFILTRATOR WATER TECHNOLOGIES4 Business Park Rd. Old Saybrook, CT 06475(800) 221-4436INFILTRATOR®water technologiesQUICK4 PLUS STANDARD CHAMBERTYPICAL TRENCH DETAILSECTION VIEW(36" WIDE TRENCH)8" INVERT34"6" COVER (min.)12" COVER H-1012"* LENGTH AND NUMBER OF TRENCHES DETERMINED BY DESIGN.34"SPACING PER CODENATIVE BACKFILLTOPSOILINFILTRATOR WATER TECHNOLOGIESQUICK4 PLUS STANDARD CHAMBERTYPICAL TRENCH DETAILSECTION VIEW(NOT TO SCALE)PRESSURE PIPEIF REQ'D, PER DESIGN
The Quick4® Plus Standard Chamber
The Quick4 Plus Standard Chamber
offers maximum strength through
its two center structural columns.
This chamber can be installed in
a 36-inch-wide trench. Like the
original line of Quick4 chambers,
it offers advanced contouring
capability with its Contour Swivel
Connection™ which permits turns
up to 15-degrees, right or left. It is
also available in four-foot lengths to
provide optimal installation flexibility.
The Quick4 Plus All-in-One 12
Endcap, and the Quick4 Periscope
are available with this chamber,
providing increased flexibility in
system configurations.
Maximum Strength
APPROVED in _____________________________________________
Quick4 Plus™ Series
Quick4 Plus All-in-One 12 Endcap Benefits:
• May be used at the end of chamber
row for an inlet/outlet or can be
installed mid-trench
• Mid-trench connection feature allows
construction of chamber rows with
center feed, as an alternative to
inletting at the ends of chamber rows
• Center-feed connection allows for
easy installation of serial distribution
systems
• Pipe connection options include
sides, ends or top
Quick4 Plus All-in-One Periscope Benefits:
• Allows for raised invert installations
• 180° directional inletting
• 12” raised invert is ideal for serial
applications
Certified by the International
Association of Plumbing
and Mechanical
Officials (IAPMO)
Quick4 Plus Standard Chamber Specifications
Size
34”W x 53”L x 12”H
(864 mm x 1346 mm x 305 mm)
Effective Length
48” (1219 mm)
Louver Height
8” (203 mm)
Storage Capacity
47 gal (178 L)
Invert Height
0.6” (15 mm), 5.3” (135 mm),
8.0” (203 mm), 12.7” (323 mm)
Quick4 Plus Standard Chamber Benefits:
• Two center structural columns offer increased stability and superior strength
• Advanced contouring connections
• Latching mechanism allows for quick installation
• Four-foot chamber lengths are easy to handle and install
• Supports wheel loads of 16,000 lbs/axle with 12” of cover
Contact Infiltrator Water Technologies’ Technical Services Department for assistance at 1-800-221-4436
4 Business Park Road
P.O. Box 768
Old Saybrook, CT 06475
860-577-7000 • Fax 860-577-7001
1-800-221-4436
www.infiltratorwater.com
U.S. Patents: 4,759,661; 5,017,041; 5,156,488; 5,336,017; 5,401,116; 5,401,459; 5,511,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending.
Infiltrator, Equalizer, Quick4, and SideWinder are registered trademarks of Infiltrator Water Technologies. Infiltrator is a registered trademark in France. Infiltrator Water Technologies is a registered trademark in Mexico.
Contour, MicroLeaching, PolyTuff, ChamberSpacer, MultiPort, PosiLock, QuickCut, QuickPlay, SnapLock and StraightLock are trademarks of Infiltrator Water Technologies.
PolyLok is a trademark of PolyLok, Inc. TUF-TITE is a registered trademark of TUF-TITE, INC. Ultra-Rib is a trademark of IPEX Inc.
© 2013 Infiltrator Water Technologies, LLC. All rights reserved. Printed in U.S.A.PLUS05 0713
Quick4 Plus™ Series
INFILTRATOR WATER TECHNOLOGIES STANDARD LIMITED WARRANTY
(a) The structural integrity of each chamber, endcap and other accessory manufactured by
Infiltrator (“Units”), when installed and operated in a leachfield of an onsite septic system in
accordance with Infiltrator’s instructions, is warranted to the original purchaser (“Holder”) against
defective materials and workmanship for one year from the date that the septic permit is issued for
the septic system containing the Units; provided, however, that if a septic permit is not required by
applicable law, the warranty period will begin upon the date that installation of the septic system
commences. To exercise its warranty rights, Holder must notify Infiltrator in writing at its Corporate
Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. Infiltrator
will supply replacement Units for Units determined by Infiltrator to be covered by this Limited
Warranty. Infiltrator’s liability specifically excludes the cost of removal and/or installation
of the Units.
(b) THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE.
THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
(c) This Limited Warranty shall be void if any part of the chamber system is manufactured by
anyone other than Infiltrator. The Limited Warranty does not extend to incidental, consequential,
special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages,
including loss of production and profits, labor and materials, overhead costs, or other losses or
expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty
coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse,
abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which
are not permitted by the installation instructions; failure to maintain the minimum ground covers
set forth in the installation instructions; the placement of improper materials into the system
containing the Units; failure of the Units or the septic system due to improper siting or improper
sizing, excessive water usage, improper grease disposal, or improper operation; or any other
event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails to comply
with all of the terms set forth in this Limited Warranty. Further, in no event shall Infiltrator be
responsible for any loss or damage to the Holder, the Units, or any third party resulting from
installation or shipment, or from any product liability claims of Holder or any third party. For this
Limited Warranty to apply, the Units must be installed in accordance with all site conditions
required by state and local codes; all other applicable laws; and Infiltrator’s installation instructions.
(d) No representative of Infiltrator has the authority to change or extend this Limited Warranty.
No warranty applies to any party other than the original Holder.
The above represents the Standard Limited Warranty offered by Infiltrator. A limited number of
states and counties have different warranty requirements. Any purchaser of Units should contact
Infiltrator’s Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase, to
obtain a copy of the applicable warranty, and should carefully read that warranty prior to the
purchase of Units.
Quick4 Plus Standard Chamber ___________________________________________________________________________________
Quick4 Plus All-in-One 12 Endcap ________________________________________________________________________________
Quick4 Plus All-in-One Periscope ________________________
EFFECTIVE LENGTH48"
12"
34"
QUICK4 PLUS
ALL-IN-ONE PERISCOPE
(360° SWIVEL)
12.7" INVERT
PRESSURIZED PIPE DRILL
POINTS LOCATIONS
(2 PLACES)
33"
18"
8" INVERT
13"
EFFECTIVE LENGTH48"
12"
34"
QUICK4 PLUS
ALL-IN-ONE PERISCOPE
(360° SWIVEL)
12.7" INVERT
PRESSURIZED PIPE DRILL
POINTS LOCATIONS
(2 PLACES)
33"
18"
8" INVERT
13" FRONT VIEW SIDE VIEW
EFFECTIVE LENGTH48"
12"
34"
QUICK4 PLUS
ALL-IN-ONE PERISCOPE
(360° SWIVEL)
12.7" INVERT
PRESSURIZED PIPE DRILL
POINTS LOCATIONS
(2 PLACES)
33"
18"
8" INVERT
13"
6"
5"9"
Item#
SEK- Orenco® Flushing Assemblies
Flushing Assemblies
Orenco® flushing assemblies provide easy
access for lateral maintenance. Flushing
assembly kits include a PVC sweep with ball
valve and a polyethylene valve box enclosure.
Orenco® flushing assemblies are available in the
following sizes:
• 1” diameter
• 1.25” diameter
• 1.5” diameter
• 2" diameter
Valve Boxes
Orenco® valve boxes are used to provide access
to flushing assemblies. Constructed of
polyethylene.
Valve Box, 7-in. diameter round enclosure
Note: Kits include VB7 valve box enclosure.
(719) 395-6764
Fax: (719) 395-3727
28005 County Road 317
P.O. Box 925
Buena Vista, CO 81211
Water &
Wastewater
• Systems
• Products
• Service Website: http://valleyprecast.com/
Email: frontdesk@valleyprecast.com
GRIFFITH, JAMES W.. JR
& MARY FARVER
3148 UPPER CATTLE CREEK RD
CARBONDALE, CO 81623-9748
Account: R029225
Tax Area: 178 - CROWN MTN
EXCLUDED BASALT AREA - 178
Acres: 597.123
Parcel: 2391-232-00-001
Situs Address:
EL JEBEL AREA, 0
Value Summary
Value By:Market Override
Land (1)$67,270 N/A
Land (2)$12,360 N/A
Land (3)$18,930 N/A
Mobile (1)$38,480 N/A
Single Family
Residence (1)
$829,060 N/A
Single Family
Residence (2)
$241,000 N/A
Extra Feature (1)$3,310 N/A
Extra Feature (2)$13,250 N/A
Extra Feature (3)$300,990 N/A
Extra Feature (4)$1,190 N/A
Extra Feature (5)$165,830 N/A
Extra Feature (6)$2,820 N/A
Extra Feature (7)$4,130 N/A
Extra Feature (8)$3,600 N/A
Extra Feature (9)$4,920 N/A
Total $1,707,140 $1,707,140
Legal Description
MBL HOME TITLE: TITLE UNK SERIAL: 229179T9489A&B YEAR:
1989 MAKE: TIT Section: 14 Township: 7 Range: 87 S1/2SW1/4-
NE1/4SW1/4-PCLIN SE1/4NW1/4 Section: 15 Township: 7 Range: 87
PCLIN SE1/4SE1/4 Section: 22 Township: 7 Range: 87 S1/2NE1/4-
PCLIN E1/2SE1/4 Section: 23 Township: 7 Range: 87 W1/2SW1/4-
S1/2NW1/4-NE1/4NW1/4-SW1/4NE1/4-NE1/4SW1
/4-PCLIN NW1/4NW1/4 Section: 26 Township: 7 Range: 87
NW1/4NW1/4 BK-0211 PG-0764 SWD 11-27-67
BK-0223 PG-0197 WD 01-03-72
BK-0241 PG-0548 QCD 08-25-75
BK-0292 PG-0689 QCD 10-12-79
BK-0292 PG-0691 QCD 10-12-79
BK-0477 PG-0333
R884305 EAS 07-16-04
Sale Data
Doc. #Sale Date Deed Type Validity Verified Sale Price Ratio Adj. Price Ratio Time Adj.
Price
Ratio
Property Record Card
Eagle County
A#: R029225 P#: 239123200001 As of: 08/28/2019 Page 1 of 11
Claire Lewandowski <claire.lewandowski@eaglecounty.us>
3148 Upper Cattle Creek Rd- Concern with proposed tank size
1 message
Claire Lewandowski <claire.lewandowski@eaglecounty.us>Fri, Nov 1, 2019 at 8:45 AM
To: Carla Ostberg <carla.ostberg@gmail.com>
Cc: environment@eaglecounty.us, mimdork@aol.com, Matthew Smith <matthew@thunderbowlarchitects.com>
Hi Carla,
I finished the review of the design submitted for the proposed OWTS at 3148 Upper Cattle Creek Rd. The question I have
is about the tank size and the 48 hour retention time with a two-compartment tank.
Regulation 43.0 b. states"The second compartment of a two-compartment septic tank may only be used as the pump tank
when the tank is specifically designed for this purpose and it can be demonstrated to the satisfaction of the ECPHA that
the minimum 48-hour detention time will not be decreased.-- "
As I see this a 3 bedroom home has a max daily flow rate of 450 gpd, so 900 gallons must be retained for 48 hours. With
the pump in the second compartment, on a maximum use day would pump up to 450 gallons of effluent, so in a 1,250
gallon tank would only retain 800 gallons for 48 hours, 100 gallons less than required.
I hope that makes sense. According to this reasoning the tank needs to be larger, either way you must demonstrate that
the 48 minimum retention time will not be decrease.
Please let me know if you have questions or concerns.
Best Regards,
Claire
Please note that beginning July 15 the Community Development Department will have new walk-in hours. The
office welcomes walk-in customers between 8 a.m. and 4 p.m. Monday through Friday, except holidays.
Claire Lewandowski, REHS
Environmental Health Specialist III
970-328-8755 (office)
970-328-8747 (direct)
environment@eaglecounty.us
www.eaglecounty.us
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
Telephone: (970) 328-8755
P.O. Box 179 - 500 Broadway, Eagle, CO 81631
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT# 2353-04 BP# 15795
OWNER: JAMES W. GRIFFITH PHONE: 970-963-2943
MAILING ADDRESS: 3148 UPPER CATTLE CREEK RD., CARBONDALE, CO 81623
APPLICANT: JIM MacDONALD PHONE: 970-963-3540
SYSTEM LOCATION: 3148 UPPER CATTLE CREEK RD., CARBONDALE, CO TAX PARCEL NO. 2391-232-00-001
LICENSED INSTALLER: JAMES W. GRIFFITH LICENSE NO. 19-04 PHONE: 970-963-2943
DESIGN ENGINEER: SOPRIS ENGINEERING, PAUL RUTLEDGE PHONE: 970-704-0311
INSTALLATION GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 3 BEDROOM RESIDENCE
1250 GALLON SEPTIC TANK 1860 SQUARE FEET OF ABSORPTION AREA CREDIT VIA 60 CHAMBERED UNITS, AS PER
ENGINEER'S DESIGN DATED 6/8/04.
SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN WITH A CLEANOUT BETWEEN THE TANK AND THE
HOUSE AND INSPECTION PORTALS IN EACH TRENCH. IF SOME AREAS IN THE PROPOSED TRENCHES NEED SOIL
REPLACEMENT FOR ADDED TREATMENT EFFICIENCY AND TO MITIGATE THE PRESENCE OF SCATTERED COBBLES
AND OR BOULDERS, THE ENGINEER RECOMMENDS THE PLACEMENT OF SUITABLE SOIL UNDERLYING A MINIMUM
OF 6 INCHES OF FILTER SAND MATERIAL PLACED TO A LEVEL GRADE WITH THE REST OF THE TRENCH. RAKE ALL
TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS AND DO NOT INSTALL IN WET WEATHER. BE SURE TO
MAINTAIN ALL APPLICABLE SET BACK REQUIREMENTS. CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE
DESIGN ENGINEER FOR THE FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION, OR
WITH ANY QUESTIONS REGARDING THE INSTALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT
BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED.
ENVIRONMENTAL HEALTH APPROVAL: VICTOR CROCCO DATE: JULY 8, 2004
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING
DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND
REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL
SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED 1250 GALLON CONCRETE SEPTIC TANK LOCATED 260 DEGREES AND 55 FEET FROM THE FIRST CLEANOUT ON
THE WEST SIDE OF THE HOUSE.
COMMENTS: THE ENGINEER'S FINAL CERTIFICATION AND AS -BUILT DRAWING WERE RECEIVED ON SEPTEMBER 23,
2004. THIS SYSTEM IS DESIGNED TO ACCOMMODATE A THREE BEDROOM RESIDENCE.
ANY ITEM NOT MEETING REQUIREMENTS WILL=TED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE INSPECTION
WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL �z e� c� DATE: SEPTEMBER 24, 2004
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970)328-8755
FAX: (970) 328-8788
TOLL FREE:800-225-6136
www.eaglecounty.us
September 24, 2004
James W. Griffith
3148 Upper Cattle Creek Rd.
Carbondale, CO 81623
EAGLE COUNTY
RAYMOND P. MERRY, REHS
Director
RE: Final of ISDS Permit #2353-04, Tax Parcel #2391-232-00-001. Property location:
3148 Upper Cattle Creek Rd., Carbondale, CO.
Dear Mr. Griffith:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sin erely,
Janet Kohl
Eagle County Environmental Health Department
ENCL: Educational Brochure
Final ISDS Permit
cc: files, September 2004 Chrono file
500 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179
September 21, 2004
y James Griffith
Griffith Ranch
3148 Upper Cattle Creek Road
Carbondale, CO 81623
RE: AS -BUILT On -site Wastewater System, Caretaker Residence, 3148 Upper Cattle Creek Road
Griffith Ranch, Eagle County Colorado
SE Job No. 24091.01 Eagle County Permit No. 2353-04
Dear Mr. Griffith:
Pursuant to Eagle County regulations, this letter and attached drawing provides documentation that the new OWS
system recently installed is in general compliance with the permitted design. Sopris Engineering has performed site
visits to inspect, measure and document the as built conditions of the constructed OWS system. The as -built size and
relative location of the new OWS system components is delineated on the attached drawing. Also attached is the
completed Eagle County document "ISDS Final Inspection Completeness Form". The OWS components have been
installed in accordance with Eagle County Regulations, the design presented in the Sopris Engineering Report and the
design drawing, dated June 8, 2004.
A double compartment, 1250-gallon concrete septic tank system has been installed with an effluent filter in the outlet
sanitary tee. Effluent discharges to a new 930 square foot soil absorption trench system configured for serial
distribution. Each trench was installed level and has an inspection port on the serial end of each trench and each
corner of the field. Adjacent trenches have a horizontal separation of 10-14 feet. The total as -built trench absorption
area is 930 SF, utilizing 60 standard leaching chambers installed in 4 serial trenches 94' long.
OWS Operation and Maintenance
The re establishment of vegetative cover over the field and responsibility for inspection and maintenance of the
system will remain with the Lot Owner or the owners representative. All components of the engineered OWS shall
be inspected on a regular basis and be properly maintained. The system and responsibility for repair and
maintenance of the system will remain with the Owner.
The OWS should require minimal maintenance. Several factors influencing the need for maintenance include: actual
wastewater flows versus design flows, the volume of kitchen/domestic waste (excluding human waste and toilet
paper), excessive household chemicals and other toxic liquids. The tank, absorption field and other system
components should be visually inspected bi-annually for debris, damage, leaks, or other potential problems. In
general, for a properly utilized system, septic tanks should be pumped and inspected every 2 - 4 years. The effluent
filters should be cleaned every six months and at the time of pumping. Absorption fields should be maintained with
suitable cover and kept free of root invasive plants. Positive surface drainage away from the absorption field should
be maintained.
We have forwarded a copy of this letter with attachments to Eagle County Environmental Health Division. Please
retain this copy for your records and As -built documentation use. If you have any questions or need any additional
informatiaaa-Dlease call.
LLC
507/WRi 6t • Suite A3 • Carbondale, CO 81623 • (970) 704-0311 • Fax (970) 704-0313 1
SopRis ENGINEERING • LLC civil consultants
ISDS Permit # Z 5^5� O¢- Installer Date:
ISDS FINAL INSPECTION
COMPLETENESS FORM
Tank is /ZS^U Gallons, Tank Material
Tank is located feet and_5 ¢716 degrees from S• Gv c ter"' `�` �'' "`' se
❑ (Permanent landmark)
Tank is located feet ands�ZWegrees from S/�'<o�rx,•�d
❑ (Permanent landmark)
Tank is set level, �Tfank lids within 8" of finished grade % sou �a
Size of field�oSquare feet, �Units,.37�Lineal feet, Technology S�.va� �u��,sv�-c�aw Css(
lean -out is installed in between tank and house (+1/100 feet)
c—"T" that goes down 14 inches in the inlet and outlet of the tank. Effluent filter on outle Yes r No
Inlet and outlet is sealed with tar tape, rubber gasket etcy�
Tank has two compartments with the larger compartment closest to the house
'' Measure distance and relative direction to field
Depth of fieleet 7 -- Z . S
interface raked
Inspection portals at the end of each trench
oper distance to set -backs
SC �S �&itJ
'---C--hambers properly installed as per manufacturers specifications. (Chambers latched, end plates
properly installed, rocks removed from trenches, etc.)
Splash plate(s) installed at least in first trench inlet 1-✓1— -emu-_`014
Type of pipe used for building sewer line-, l -,?-S' , leach field
Other
Inspection meets requirements
Copy form to installer's file if recommendations for improvement were suggested
ACTIONS TAKEN:
i01 10: E3R FRUM: ERULE CUUN I Y ENV HEH 3 (06ew (HU I U: y'ly (W'Jb.3ff.57b
I'ncoiiLplete Applications Will NOT Be Accepted
(Site Plan MUST be attached)
ISDS Permit # o
Building Permit # / _
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. O. BOX 179
EAGLE, CO 81631
Eagle (970)328-8755, Fax (970)328-0349, El Jebel (970)927-3823
FEE SCHEDULE
* APPLICATION FEE $350.00
* THIS FEE INCLUDES THE ISDS PERMIT, SITE EVALUATION (PERCOLATION TEST,
* SOIL PROFILE OBSERVATION) AND FINAL INSPECTION
* ADDITIONAL FEES MAY BE CHARGED IF A REINSPECTION IS NECESSARY, OR A
* PRE -CONSTRUCTION SITE VISIT OR CONSULTATION IS NEEDED
* REINSPECTION FEE $47.00, PRE -CONSTRUCTION SITE VISIT FEE $86.00
* MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
PROPERTY OWNER: � VS f %+�- tM4 J
MAILING ADDRESS: l y U�Lffff ONE
APPLICANT/CONTACT PERSON: ��►off-�P� (} Ee � PHONE: I -3JW
LICENSED SYSTEMS CONTRACTOR: PHONE: �9b3 Z4y-3
COMPANY/DBA:
Co T• �iSc, r (GsQ
PERMIT APPLICATION IS FOR: O( NEW TY"7. ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVID22UAL SEWAGE QSAL SYSTEM:
�J
Legal Description: q 12 _
Tax Parcel Number:
Physical Address:
-— Lot Size:
BUILDING TYPE: (Check applicable category)
()0 Residential/Single Family
( ) Residential/Multi-Family*
( ) Commercial/Industrial*
G�
9'16 z3
Number of Bedrooms 3
Number of Bedrooms
Type
*These systems require design by a Registered Professional Engineer
TYPE OF WATER SUPPLY- (Check applicable category)
( ) Well (r Spring ( ) Surface
( ) Public Name of Supplier -
APPLICANT SIGNATURE: Date: /7
AMOUNT PAID:
0
Of
RECEIPT #: ��� DATE: �0
CHECK #: Pi.`) / CASHIER:
CD
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX: (970) 328=8788
TOLL FREE:800-225-6136
www.eaglecounty.us
DATE:
TO:
FROM:
EAGLE COUNTY
July 8, 2004
James W. Griffith
Eagle County Department of Environmental Health
RAYMOND P. MERRY, REHS
Director
RE: Individual Sewage Disposal System Permit #2353-04, Tax Parcel #2391-232-00-001.
Property Location: 3148 Upper Cattle Creek Rd., Carbondale, CO., Griffith
caretaker unit.
Enclosed is your ISDS Permit #2353-04 and a copy of the engineer, s design for this system. The
permit is valid for 120 days or for the duration of your current building permit for this property.
The enclosed copy of the permit must be posted at the installation site. Any changes in plans or
specifications invalidate the permit unless otherwise approved. Please note any special
requirements that may have been added to the design by this Department.
Systems that are designed by a Registered Professional Engineer must be certified by the
engineer indicating that the system was installed as specified. Eagle County Environmental
Health must also view the installation prior to back filling. Please call well in advance for
your final inspection. Your TCO will not be issued until our office receives this certification
from the engineer and views the installation.
Please note that our ISDS Permit specifications are typically minimum requirements only and
should be brought to the property owner's attention in case they may wish to install a system capable
of handling larger wastewater,flows.
This permit does not indicate conformance with any other Eagle County requirements. Please
notify this office if you have not been contracted to perform this installation.
If you have any questions, please feel free to contact us at (970) 328-8755.
cc: ISDS file # 2353-04
Sopris Engineering, Paul Rutledge
July 2004 Chrono file
Encl: ISDS Permit #2353-04
500 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179
June 8, 2004
James Griffith
Griffith Ranch
3148 Upper Cattle Creek Road
Carbondale, CO 81623
RE: Caretaker Residence, Proposed On -site Wastewater System, 3148 Upper Cattle Creek Road
Griffith Ranch, Eagle County Colorado
SE Job No. 24091.01
Dear Mr. Griffith:
Pursuant to your request, this letter/report presents our findings in regard to the feasibility and design for an
engineered Onsite Wastewater System (OWS) at the above referenced Site. This design is based on our
evaluation of the site conditions with information provided by both of you for use in supporting your
application to Eagle County. Our recommendations are in accordance with Eagle County and the State of
Colorado ISDS Regulations. Eagle County must permit any proposed improvement to the site. We have
reviewed the information forwarded to us, formulated an OWS design and created a site plan with
construction details as part of our scope of work.
Conclusions
Based on our findings we believe that the design and installation of an approved OWS is feasible in
accordance with the Regulations of Eagle County and the State of Colorado. We recommend that a new
1250 gallon septic tank be installed that will discharge effluent to a 930 square foot soil absorption trench
system. The soil absorption system can be installed in natural soils and will be located within the general
area down gradient of the proposed house, as delineated on the attached plan. The system will meet all
required setbacks and be installed within the general boundaries indicated on the plan. Our design is
outlined below and delineated on the attached site plan.
Site Location
The subject site is located approximately 3 miles north of El Jebel at 3148 Upper Cattle Creek Road, on the
Griffith Ranch, Eagle County Colorado in Eagle County, Colorado. The site is situated in Section23, T 7
S, R 87 W of the 6tn P.M. The Site is part of a large ranch.
Existing Site Conditions
The site is located on irrigated agricultural lands. The site has a moderate slope (10-15%) toward the west.
The existing ground surface in the proposed absorption field area has an approximate slope of 10%. The
site is covered with pasture grass and weeds. Domestic water is supplied by a well. There are no wells
within 100 feet of the general vicinity of the proposed absorption field. An existing ranch manager's house
is located across the road from the proposed house and is going to be removed.
502 Main Street •
Suite A3 • Carbondale, CO 81623 •
(970) 704-031 1 • Fax
(970) 704-0313
SOPRIS
ENGINEERING e
LLC
civil consultants
James Griffith
SE Job No. 24091.01
June 8, 2004
Page 2
Proposed Site Conditions
It is our understanding that you intend to construct a 3-bedroom home with a detached garage. The
maximum number of rooms to be utilized as bedrooms in the future is 3. Therefore the system is designed
to handle the flow from a 3-bedroom house. The proposed improvements will include a new ISDS system
with appropriate site grading. The new structure is to be generally located as shown on the scanned site
plan provided by the owner.
Subsurface Conditions
A subsurface investigation and percolation test was conducted on April 30, 2003 by CTL/Thompson, Inc.
(CTL). The results are attached in the CTL report dated June 16, 2003, Job Number GS-3899.The subsoil
encountered at the site consists of 1/2 to 1 feet of topsoil overlying stiff silty to sandy clay with gravels to a
depth of 10 feet. Groundwater was not encountered in the test profile boring.
Percolation testing utilized three test borings, which yielded similar absorption rates. The fastest measured
rate was 120 minutes per inch and the slowest measured rate was 60 minutes per inch. The average
percolation rate is 80 minutes per inch and should be suitable for a conventional absorption system.
Additional geotechnical evaluations and inspections by the engineer and Eagle County should be
performed during initial stages of construction to verify assumptions made for the OWS design. An
additional profile hole needs to be excavated for visual inspection by the Eagle County Environmental
Health Specialist and the Engineer prior to excavation of the absorption field and prior to issuing the final
permit. The evaluations and inspections may result in modifications to the design that may include field
size revisions and possible soil replacement in select areas if needed. Sufficient notice to Eagle County and
the Engineer by the owner/contractor needs to be made in order to schedule the site visit.
Design Criteria
The absorption field is designed based on utilizing the suitable native soil for treatment in trenches.
Additional percolation test may be desirable to confirm the soil's acceptance rate.
Based on the reported percolation rate and observations of the percolation holes and test pit we have
designed a system that will treat the calculated quantity of effluent with native soils utilizing the Long
Term Acceptance Rate (LTAR) for the native soils per Eagle County requirements.
Based on the reported percolation rate and observations of the percolation borings and test pit we have
designed a system that will treat the calculated quantity of effluent with native soils utilizing the Long
Term Acceptance Rate (LTAR) for the native soils. The LTAR is based on the interpolation of absorption
rates corresponding to the average percolation rate. The wastewater application rates are from Table 7-2,
EPA Design Manual, Onsite Wastewater Treatment and Disposal Systems. The loading rate based on the
assumed percolation rate is approximately 0.37 gallons per day per square foot of soil absorption area. The
treated effluent will then be absorbed into the natural soils across the bottom area and a portion of the
sidewall areas of the trench excavations.
James Griffith
SE Job No. 24091.01
June 8, 2004
Page 3
The absorption field is designed based on utilizing the suitable native soil for treatment in trenches.
However if some areas in the proposed trenches need soil replacement for added treatment efficiency and
to mitigate the presence of scattered cobbles and or boulders, we recommend the placement of suitable soil
underlying a minimum of 1/2 foot of filter sand material placed to a level grade with the rest of the trench.
Proposed residence is a 3-bedroom house. The design flow is calculated as follows:
Residence unit - 3 bedrooms @ 2 person /bedroom = 6 person
From the Eagle County I. S. D. S. Regulation;
Max. Design flow (Qd) = # of people x 1.5(avg. flow) gal/person/day.
Gallons per day for the subject house 75 gal/person/day
Qd = 6*75*1.5 =675 Qa� 1/day
Septic Tank Design
Residence
Q = 6*75*1.5 =675
Volume (V) of tank = Design Flow * 1.25
(30 hour retention time)
V = 675 gal/day * 1.25 = 844
Use one 1250-gallon septic tank to provide additional primary treatment and extend
periodic pumping schedules.
Soil Absorption System Design
The percolation test indicated percolation rate between 60 and 120 minutes per inch with an average rate of
80 minutes per inch. Therefore this range is used to estimate a loading rate for the soil and size the
absorption area required for treatment utilizing' native soils.
A = Absorption Area
Long Term Acceptance Rate method (LTAR):
LTAR loading rate for soil with perc rate between
60 and 120 min/inch = 0.37 gal/S.F./day
A=Q/LTAR = 675/0.37 1824 sq. ft.
We recommend using a gravelless leaching chamber absorption trench system. The county allows up to a
50% adjustment in absorption area if gravelless leaching chambers are used in suitable soils. The
equivalent Absorption area per chamber unit is 15.5 S.F.
Apply a 50% reduction for utilizing gravelless infiltration chambers in a trench configuration.
A = 1824 sq. ft. x 0.50 = 912 sq. ft. (Apply a 50% reduction)
Assume 15.5 square feet per chamber: 912 sq.ft. = 58.8 chambers Use 60 chambers
15.5 sq.ft/chamber
James Griffith
SE Job No. 24091.01
June 8, 2004
Page 4.
We recommend using a trench system composed of 4 trenches 94 feet long and 3 foot wide, containing 15
standard leaching chamber units in each trench connected for serial distribution. Excavate absorption
trenches to accommodate a minimum 1131 sf of interior surface area. Pursuant to previous discussions
with Eagle County Environmental Health, serial distribution is recommended.
Distribution
An effluent filter shall be installed on the outlet of the secondary chamber in the septic tank. The filter
should be inspected every six months. Maintenance shall include cleaning the filter as needed and after
periodic pumping of the tank.
We recommend that the trenches be connected with the inlet pipe coming into the inlet port of the first
serial trench chamber. The effluent flow will run the length of the first trench discharge through the outlet
pipe connected to the end chamber. The outlet pipe will run across the minimum 6' separation distance to
the second serial trench and connect to the inlet port of the first chamber. The flow will run the length of
the second trench and connect the same way to the first chamber in the succeeding trenches. Each trench
will be constructed level with successive trenches installed at a lower elevation than the preceding trench to
accommodate drainage in the distribution pipes and surface grades. Each trench shall be constructed not to
exceed a maximum depth of 4 feet. The method allows for the sloped terrain, provides increased longevity
of the system and allows for maintenance and/or partial reconstruction if needed. An inspection port
should be installed on the top mid -point cut out at the serial end chamber in each trench. This will allow
for checking the performance of the system over time.
ISDS Operation and Maintenance
The system shall be inspected on a regular basis and be properly maintained. The system and
responsibility for repair and maintenance of the system will remain with the Lot Owner. The onsite system should require minimal maintenance. Several factors influencing the need for
maintenance include: actual wastewater flows versus design flows, the volume of kitchen/domestic waste
(excluding human waste and toilet paper), excessive household chemicals and other toxic liquids. The
tank, absorption field and effluent filter should be visually inspected bi-annually for debris, wear, damage,
leaks, or other potential problems. In general, for a properly utilized system, septic tanks should be
pumped and inspected every 2 - 4 years. The effluent filters should be cleaned every six months and at the
time of pumping. Absorption fields should be maintained with suitable cover and kept free of root
invasive plants. Positive surface drainage away from the absorption field should be maintained.
Construction and Inspections
Prior to construction of the permitted system the engineer should be contacted by the contractor and owner
well in advance to provide adequate time to discuss the system components with the contractor, answer
questions, resolve any conflict issues and schedule inspection site visits based on construction progress.'
County Regulations require that the Design Engineers of record perform site inspections of the permitted
system during construction and provide "As -Built" documentation of the installed. system to the County
after construction is complete. The Regulations further require site inspections and approval by the County
Environmental Health Department of the exposed components of the system prior to backfilling.
James Griffith
SE Job No. 24091.01
June 8, 2004
Page 5
Therefore the County Environmental Health Department should also be contacted and notified of the
construction schedule.
General Notes
1) All materials and installation practices shall conform to the Eagle County Individual Sewage Disposal
Regulation.
2) All sewer lines and distribution lines in the system shall be 4" Schedule 40 or SDR-35 PVC unless
specified otherwise on the plans.
3) Add a two-way clean out on the service line from the proposed house.
4) The system shall be plumbed to distribution effluent into the trenches with serial distribution.
5) The contractor shall ensure that the concrete septic tank and sewer lines are watertight.
6) The trench area must be protected to prevent damage from vehicular or livestock traffic and must be
crowned to divert drainage runoff away from the trenches to minimize surface infiltration.
7) The infiltration chambers shall be installed level in each trench. A splash plate shall be installed on the
trench bottom surface below the inlet in each serial trench to prevent scouring from the effluent or an
appropriate chamber end plate may be used to prevent scouring from the effluent. The top of the
backfill over the chambers shall be covered with filter fabric or other suitable pervious material to
prevent the migration of fines from the overlying topsoil layer.
8) The trenches must have a minimum cover of 12 inches. A final cover of topsoil suitable for vegetation,
a minimum 4" deep, shall be placed from the top of the pervious cover layer to the finished surface
grade.
9) The absorption trenches must be sodded or covered with vegetative ground cover.
Our design and recommendations are based upon data supplied to us by others. If subsurface or site
conditions are found to be different from those presented in this report, we should be notified to evaluate
the effect it may have on the proposed ISDS. If the County Environmental Health Department requests
changes or modifications to this design, we should be contacted to evaluate the effect on the ISDS.
If you have any question or need any additional information, please call.
Sincerely,
SOPRIS ENGINEERING; LLC
Paul} die
ISDS Permit # 3 5 3 v ti Inspector Date
ISDS Final Insuection
Completeness Form
Tank is r gal. Tank Material �• �I' ° c �' M �- c r -� 1 �� �a e c o s �, a c a
Tank is located S 5 ft. and 1&-0 degrees from
Tank is located ft. and degrees from
-f— Tank set level. Tank lids within 8" of finished grade.
Size of field ft2 /o d units ;lineal ft. Technology
e 5 Cleanout is installed in between tank and house(+ 1/100ft).
"T" that goes down 14 inches in the inlet and outlet of the tank. Effluent filter on outlet -for No
e"S Inlet and outlet is sealed with tar tape, rubber gasket etc.
Tank has two compartments with the larger compartment closest to the house.
d ,
Measure distance and relative direction to field. 1 3 15 b 0 �''
Depth of field
3 Soil interface raked.
4-2 5_ Inspection portals at the end of each trench.
Proper distance to setbacks.
Chambers properly installed as per manufacturers specifications. (Chambers latched, end plates prop
installed, rocks removed from trenches, etc.)
Splash plate(s) installed at least in first trench inlet.
3
Type of pipe used for building sewer line J 9 , leach field
Other .
Inspection meets requirements.
Copy form to installer's file if recommendations for improvement were suggested.
ACTION TAKEN:
Setbacks
Well Potable House Property Lake Dry Tank Drain Field
Water Lines line Stream Gulch
Field
100
25
20
10
50
25 10
Tank
50
10
5
10
50
10 * 10
1 1
■■■■■■■■■■■■■!E■■■■■■■■■■■■■■
■■■■■■■■■■■■■o■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■o■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■•■■■■■■
■■■■■■■■■■■■■■■■■■■■■■®■■m■■■■
■■■■■■■■■■■■■■■■■■■■■ ■■■EMMIN
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■m■■■ ■■■■
■■■■■■■■■■■■■■■■■■■■■■■mmm■■■■
■■■■■■■■■■■■■■■■■■■■mmmm■■I■■■■
■■■■■■■■■■■■■■■■, 'MMO I■■■■I■■■■
■■■■■■■■■■■■■■■►% oommum■■ IN
■■■■■■■■■■■■■m%m■m■■■m■m■m■■■■
■■■■■■■■■■■■mmmm/m■■■■■11■■■■■■
■■■■■■■■■■■mmmm■■m,■■■■LI®■'■■■
■■■■■■■■■■C■■�'mmmmm■■■■■��■i�■■■■
■■■■■■■■■■■mmmmm/�.■o■■®■■■■■■■
■■■■■■■■■■■EmMmm■M%■■■■■■■■■■■
■■■■■■■■■■■■■mmmmmm■■■■■■■■■■
■■■■■■■■■■■■■mmmm■■■■■■■■■■■■■
■■■■■■■■■■■■■■►©iTii■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■a
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■e■e■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■a■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
GEOTECHNICAL INVESTIGATION
PROPOSED CARETAKERS RESIDENCE
3148 UPPER CATTLE CREEK ROAD
EAGLE COUNTY, COLORADO
Prepared For:
MR. JAMES GRIfFITH
3148 Upper Cattle Gr4b'',Road
Carbondale;;; , 91623
4�
Job No. GS-3899
June 16, 2003
CTL/THOMPSONg INC.
CONSULTING ENGINEERS
234 CENTER DRIVE 0 GLENWOOD SPRINGS, COLORADO 81601 ® (970) 945-2809
TABLE OF CONTENTS
SCOPE 1
SUMMARY OF CONCLUSIONS 1
SITE CONDITIONS 2
PROPOSED CONSTRUCTION 2
SUBSURFACE CONDITIONS 3
SITE EARTHWORK 3
FOUNDATION 4
FLOOR SYSTEM AND GARAGE FLOOR SLAB 5
FOUNDATION WALLS 6
PERCOLATION TESTING 7
SURFACE DRAINAGE 8
LIMITATIONS g
FIGURE 1 - APPROXIMATE LOCATIONS OF EXPLORATORY BORINGS
FIGURE 2 - SUMMARY LOGS OF EXPLORATORY BORINGS
FIGURES 3 AND 4 - SWELL/CONSOLIDATION TEST RESULTS
FIGURES 5 THROUGH 7 - PERCOLATION TEST RESULTS
FIGURE 8 - EXTERIOR FOUNDATION WA.L*. RAIN
f.
TABLE 1 - SUMMARY OF LABORATOR!,:V S ING
MR. JAMES GRIFFITH
CARETAKERS RESIDENCE
CTUT JOB NO. GS-3899
SCOPE
0
This report presents the results of our geotechnical investigation for the
proposed caretakers residence to be built at 3148 Upper Cattle Creek Road in Eagle
County, Colorado. We conducted this investigation to evaluate subsurface
conditions at the site and provide foundation recommendations for the caretakers
residence. Our report was prepared from data developed during drilling of
exploratory borings atthe site, results of laboratory testing, engineering analysis and
our experience with similar conditions. This report includes a description of the
subsurface conditions observed in our exploratory borings, and presents
recommendations for design criteria for the recommended foundation and floor
systems, and geotechnical and construction criteria for details influenced by the
subsoils. Recommendations contained in this report were developed based on our
understanding of the planned construction. If plans differ significantly from the
descriptions contained in this report, we should be informed so that we can check
that our recommendations and design criteria are appropriate. A summary of our
conclusions is presented below.
SUMMARY OF CONCL
1. S u ace conditions encountered in our exploratory borings
co ed of a surficial layer of organic sandy clay "topsoil" above
sandy clays with scattered gravels to the maximum explored depth of
20 feet below the existing ground surface. In our TH-2 the clays were
underlain by silty to clean sands at 10 feet below the existing ground
surface. Free ground water was not observed in our exploratory
borings at the time of drilling.
2. We recommend constructing the residence on footing foundations
supported entirely by the undisturbed, native clay soils. Design and
construction criteria for footings are presented in the report.
3. We judge potential differential movement will be low for slabs -on -
grade supported by the native clay soils after scarifying, moisture
conditioning and compacting or on densely compacted structural fill.
Design and construction criteria for slabs -on -grade are presented in
the report.
MR. JAMES GRIFFITH
CARETAKERS RESIDENCE 1
CTUT JOB NO. GS-3899
4. Surface drainage should be designed to provide for rapid removal of
surface water away from the residence.
SITE CONDITIONS
The site is located on the Griffith Property at 3148 Upper Cattle Creek Road
which is approximately 3 miles north of El Jebel intersection on Highway 82 in Eagle
County, Colorado. Access to the site is from Upper Cattle Creek Road to an access
drive approximately 400 feet to the north of the proposed caretakers residence
location. The proposed caretakers residence is situated in an existing irrigated
pasture area. Ground surfaces slope down to the northwest at grades measured and
visually estimated at approximately 10 to 15 percent. Vegetation consists of irrigated
pasture grasses and weeds.
PROPOSED CONF�ION
We P-5nd the proposed single-family residence will be a one story,
manufacturede (modular) placed on a permanent foundation. An attached
garage may also be constructed. Floors in living areas will be structurally supported
by the foundation system with crawl space below. Floors in the garage will be slabs -
on -grade. Foundation loads are expected to vary between 1,000 and 2,000 pounds
per lineal foot of foundation wall with maximum interior column loads of 15 kips. We
were told that maximum excavation depths will be on the order of 6 to 8 feet at the
uphill (east) part of the building and approximately 3 to 4 feet at the downhill (west)
part of the building. Completed wall backfill depth may be slightly more than
excavation depth as final grades are adjusted for drainage. If construction will differ
significantly from the descriptions above, we should be informed so that we can
adjust our recommendations and design criteria, if necessary.
MR. JAMES GRIFFITH
CARETAKERS RESIDENCE
CTL/T JOB NO. GS-3899 2
SUBSURFACE CONDITIONS
We directed the drilling of two exploratory borings (TH-1 and TH-2), one profile
boring (Profile) and three percolation borings (P-1, P-2 and P-3) to investigate
subsurface conditions at the site. The approximate locations of our borings are
shown on Figure 1. Drilling operations were directed by our engineering geologist
who logged subsurface conditions encountered in the borings and obtained samples
of the excavated soils. Graphic logs of the soils encountered in our exploratory
borings are shown on Figure 2.
Subsurface conditions encountered in our exploratory borings consisted of
a 0.5 feet thick surficial layer of organic sandy clay "topsoil" with vegetative debris
above stiff to very stiff, moist, sandy clays with gravels to the maximum explored
depth of 19.5 feet below the existing ground surface. In our TH-2 the clays were
underlain by dense to very dense, moist, silty to clean sands at 10 feet below the
existing ground surface. No free ground water was found in our exploratory borings
during our drill g operations
SITE E?ORK
We judge the clay soils to have a low swell potential.
ading plans were not provided to us. Fill may be required to obtain
subgrade elevations for the garage floor and driveway. Areas which will receive fill
should be stripped of vegetation, organic soils and debris. The on -site soils free of
organic matter, debris and rocks larger than 6 inches in diameter can be used as fill.
Fill should be placed in loose lifts of 8 inches thick or less and moisture
conditioned to within 2 percent of optimum moisture content. Fill placed outside the
building footprint should be compacted to at least 95 percent of standard Proctor
(ASTM D 698) maximum dry density. Structural fill below garage floor slabs should
be compacted to at least 98 percent of ASTM D 698 maximum dry density. Moisture
MR. JAMES GRIFFITH
CARETAKERS RESIDENCE
CTLIT JOB NO. GS-3899 3
content and density of fill and structural fill should be checked by a representative
of our firm during placement.
We anticipate excavations for the building foundation and utilities can be
accomplished using conventional, heavy-duty excavation equipment. Excavation
sides will need to be sloped or braced to meet local, state and federal safety
regulations. We believe the native clays will classify as Type B soils based on OSHA
standards governing excavations. Temporary slopes deeper than 5 feet should be
no steeper than 1 to 1 (horizontal to vertical) in Type B soils. Contractors should
identify the soils encountered in the excavations and refer to OSHA standards to
determine appropriate slopes.
Soils removed from the excavation should not be stockpiled at the edge of the
excavation. Excavated soils should be placed at a distance from the top of the
excavation equal to at least the depth of the excavation.
Free ground water was not observed in our exploratory borings at the time of
drilling. We do not anticipate excavations for foundations or utilities will penetrate
ground water, however, excavations should be sloped to a gravity discharge or to
a temporary sump where water can be removed by pumping. The ground
surrounding the excavations should be sloped to direct runoff away from the
excavations.
FOUND
r exploratory borings indicate the native clay soils will be at anticipated
footing depths. The clay soils are expansive. The foundation should be designed to
resist uplift from expansive clays. We recommend constructing the residence on
footing foundations with a minimum deadload. Footings should be supported by the
undisturbed, native clays. The completed foundation excavation should be
inspected by a representative of our firm, prior to placing forms, to confirm that the
MR. JAMES GRIFFITH
CARETAKERS RESIDENCE
CTL/T JOB NO. GS•3899 4
native clays are exposed and suitable for support of the designed footings. We
anticipate maximum total movement of footing foundations with a minimum
deadload supported on the native clays will be less than 1 inch with differential
settlement of about '/2 the actual total settlement. Recommended design and
construction criteria for footings are presented below.
1. Footing foundations should be supported by the undisturbed, native
clay soils. Soils loosened during excavation or the forming process
for the footings should be removed or the soils can be re -compacted
prior to placing concrete.
2. Footings supported by the native clays can be designed for a
maximum allowable soil bearing pressure of 3,000 psf with a minimum
deadload of 750 psf or as high as practical.
3. Continuous wall footings should have a minimum width of at least 14
inches. Foundations for isolated columns should have minimum
dimensions of 18 inches by 18 inches. Larger sizes may be required,
depending upon foundation loads.
4. Grade beams and foundation walls should be well reinforced, top and
bottom, to span undisclosed loose or soft soil pockets. We
recommend reinforcement sufficient to span an unsupported distance
of at least 10 feet. Reinforcement should be designed by a qualified
structural engineer.
5. The soils beneath exterior footings should be protected from freezing.
We recommend the bottom of footings be constructed at a depth of at
least 36 inches below finished exterior grades for frost protection. The
Eagle County building department should be consulted to verify the
required frost protection depth.
FLOOR SYSTEM AND GA LOOR SLAB
Floors in living ar s will be structurally supported by the foundation with
crawl space below. The garage floor will be slabs -on -grade. Based on our laboratory
test data and our experience, we judge garage slab -on -grade construction can be
supported by the native clay soils after scarifying, moisture conditioning and
compacting or by densely compacted, structural fill built with the on -site soils with
low risk of differential movementand associated damage. We recommend the garage
MR. JAMES GRIFFITH
CARETAKERS RESIDENCE
CTUT JOB NO. GS•3899 5
0
floor be supported entirely by either the native clay soils or on densely compacted
structural fill. Structural fill placed to attain subgrade elevations for the garage floor
slab and exterior concrete flatwork should be in accordance with the
recommendations outlined in the SITE EARTHWORK section.
We recommend against providing a gravel layer below floor slabs since the
gravel layer will allow wetting of the entire area below the slab from a single water
source. We recommend the following precautions for slab -on -grade construction at
this site. Slabs should be separated from exterior walls and interior bearing
members with slip joints which allow free vertical movement of the slabs. Exterior
patio and porch slabs should be isolated from the residence. Frequent control joints
should be provided, in accordance with American Concrete Institute (ACI)
recommendations, to reduce problems associated with shrinkage and curling. Our
experience indicates panels which are approximately square generally perform better
than rectangular panels.
FOUNDATIO NS
le -. �
Fo I ion walls should be designed for lateral earth pressures where
backfill is not to about the same elevation on both sides of the wall. Many factors
affect the values of the design lateral earth pressure. These factors include, but are
not limited to, the type, compaction, slope and drainage of the backfill, and the
rigidity of the wall against rotation and deflection. For a very rigid wall where
negligible or very little deflection will occur, an "at -rest" lateral earth pressure
should be used in design. For walls which can deflect or rotate 0.5 to 1 percent of
wall height (depending upon the backfill types), lower "active" lateral earth pressures
are appropriate. Our experience indicates foundation walls can deflect or rotate
slightly under normal design loads, and that this deflection results in satisfactory
wall performance. Thus, the earth pressures on the walls will likely be between the
"active" and "at -rest" conditions.
MR. JAMES GRIFFITH
CARETAKERS RESIDENCE 6
CTUT JOB NO. GS-3899
If the on -site soils are used as backfill, we recommend design of below -grade
walls using an equivalent fluid density of at least 50 pcf for this site. This equivalent
density does not include allowances for sloping backfill, surcharges or hydrostatic
pressures. The recommended equivalent density assumes deflection; some minor
cracking of walls may occur. If very little wall deflection is desired, a higher
equivalent fluid density may be appropriate for design. Our recent experience
indicates most below -grade walls designed with 50 pcf to 55 pcf equivalent fluid
density have performed satisfactorily.
The structural engineer should also consider site specific grade restrictions
and the effects of large openings on the behavior of the walls. Backfill placed
adjacent to foundation wall exteriors should be free of organic matter, debris and
rocks larger than 6 inches in diameter. Backfill should be moisture conditioned to
within 2 percent of optimum moisture content and compacted to at least 95 percent
of standard Proctor (ASTM D 698) maximum dry density.
Water from rain, snow melt and surface irrigation of lawns and landscaping
frequently flows through relatively permeable backfill placed adjacentto a residence
and collects on the surface of relatively impermeable soils occurring at the bottom
of the excavation. This can cause wet or moist conditions in crawl space areas after
construction. To reduce the likelihood water pressure will develop outside
foundation walls and reduce risk of accumulation of water in the crawl space, we
recommend provision of a foundation drain. The drain should consist of a 4-inch
diameter, open joint or slotted pipe encased in free draining gravel. The drain should
lead to a positive gravity outfall, or to a sump pit where water can be removed by
pumping. A typigfoundation drain detail is presented on Figure 8.
PERCOLA ° �ESTING
We performed percolation testing in the planned percolation field area. One
profile boring and three percolation boringswere drilled at the approximate locations
MR. JAMES GRIFFITH
CARETAKERS RESIDENCE 7
CTUT JOB NO. GS-3899
shown on Figure 1. Graphic logs of the soils encountered in the borings are shown
on Figure 2. Our engineering technician performed percolation testing in the borings
on April 30, 2003. Percolation test results are presented on Figures 5 through 7.
Percolation rates were very slow at the percolation field area. According to state and
local regulations percolation rates outside the range of 5 min/per inch to 60 min/per
inch require that the septic system be designed by a qualified engineer.
SURFAC AMAGE
e;z"
rface drainage is critical to the performance of foundations, floor slabs and
concrete flatwork. We recommend the following precautions be observed during
construction and maintained at all times after the residence is completed:
1. The ground surface surrounding the exterior of the residence should
be sloped to drain away from the residence in all directions. We
recommend providing a slope of at least 12 inches in the first 10 feet
around the residence, where possible. In no case should the slope be
less than 6 inches in the first 5 feet.
2. Backfill around the exterior of foundation walls should be placed in
maximum 10 inch thick loose lifts, moisture conditioned to within 2
percent of optimum moisture content and compacted to at least 95
percent of standard Proctor (ASTM D 698) maximum dry density.
3. Roof downspouts and drains should discharge well beyond the limits
of all backfill. Splash blocks and downspout extensions should be
provided at all discharge points.
4. Landscaping should be carefully designed to minimize irrigation.
Plants used near foundation walls should be limited to those with low
moisture requirements; irrigated grass should not be located within 5
feet of the foundation. Sprinklers should not discharge within 5 feet
of the foundation and should be directed away from the building.
5. Impervious plastic membranes should not be used to coverthe ground
surface immediately surrounding the residence. These membranes
tend to trap moisture and prevent normal evaporation from occurring.
Geotextile fabrics can be used to control weed growth and allow some
evaporation to occur.
MR. JAMES GRIFFITH
CARETAKERS RESIDENCE
CTUT JOB NO. GS-3899 8
0
The exploratory borings drilled at the site provide a reasonably accurate
picture of subsurface conditions. Variations in the subsurface conditions not
indicated by our borings will occur. We should observe the completed foundation
excavation to confirm the native clays are exposed and suitable for support of the
footings as designed.
Our report was based on conditions disclosed by our exploratory borings,
engineering analysis and our experience. Criteria presented reflect our
understanding of the. proposed construction. If construction will differ significantly
from the descriptions in this report we should be informed so that we can check that
our recommendations and design criteria are appropriate.
This investigation was conducted in a manner consistent with that level of
care and skill ordinarily exercised by engineering geologists and geotechnical
engineers currently practicing under similar conditions in the locality of this project.
No other warranty, express or implied, is made. If we can be of further service in
discussing the contents of this report or in the analysis of the influence of the
subsoil conditions on the design of the structure, please call.
CTUTHOMPSON, INC. Reviewed by:
Wilson L. "L'wden, C.P.G. John Mechling, P.E.
Engineerin e,#Ibgist Branch Manager
LB:JM:cd
(5 copies sent)
MR. JAMES GRIFFITH
CARETAKERS RESIDENCE
CTUT JOB NO. GS-3899 9
SCALE: 1 °= 100'
Existing Caretakers Residence
Existing Access Drive
James Griffith
CaretWu" Realdence
Job No. GS-3899
x
O
^AF
� • � 10
X xx Existing Fenc
o=
•P-1 \ ® • TH-1
P-3 Profile
P-2 TH-2
Proposed
Caretakers
Residence
�a
cr
o Approrte
a� Loc# 0, of
'�s s Ex - .story
° Borings
F19. 1
TH-1
C
5
10
15
20
20
36/12
50/10
50/6
TH-
M
Ic sandy clay "topsoil", soft,
'hoist, dark brown. (OL)
silty to sandy with gravels,
'o very stiff, moist, tan,
(CL)
silty to clean with silty gravel
dense to very dense, moist,
'-own. (SM, SP, GM)
,sample. The symbol 36/12
4es that 36 blows of a 140
hammer falling 30 inches
required to drive a 2.5 inch
ampler 12 inches.
story borings were drilled on
'4, 2003 with 4—inch diameter,
sous flight auger and a
mounted drill rig.
ie ground water was found
exploratory borings at the
)f drilling.
explora! Wings are subject
expl. nlimitations and
sWW �q�� +��ontained in this report.
Job No. GS-3899 Fig. 2
7
6 ---------------------- ------------- j --------- r ------- r --- 1 -----------------------------
---------------------- ------ --- ------- ------- --------- ------------------------ - ---------- ......
-------------------- :
------------ --------- --------- - - ----------------------------------------- ............ --------- ------- ------- ----------------- -- - ---------------------
4 ---------------------------------------
---------- I --------- --------- I ------- I ----T-------- -------------------- - ----------- 7 --------- 1
------- --- - --------------- .......
EXPANSION AbElk CONSTANT:
PRESSUREDUE TO WETTING
2 ----------------------------------- ......... - - --- ------- -------------- --------- --------- .......... _ ............ .................... --------- .......... ------- ...........
z
O
z --------- ------------
------------
---------- - ---------------- ---------- ------------------ ........... ...... ---------- ------------------------------------------------------- ---------
W
----------- -- ------------------------
0 ----------------- ...... I --------- r ---- - --- - -- - - - ---------------- ---- --- t__,_ ----------------------- --
z
0
co
........... ------ ---- - --- -- ------------------ --------- ------------ -------------------- - ----------- --------- ------------
co ---------------------- ... . .......
a.
0 -2 ----------- --------------------------------- --------------------------
----------- ----------------- ---------------- ----------------------------- - ------------ - ------
- ----------- -------- -------- ----------
------------------------------------------------------ ............. .... r. ..................... . ......... ---------- - --- ------- ---------------------------
-4 --------- --------------------------------- ------ -------------------- ........ ---------- -------------------- ............ - ------- L ..........
-------------- ------
............ ............ -------- : ........... ........ ------------ -------- ---------- I ------------- -------- - ------------------------------ ------ -- ...... . -------- ......
-7 ------ ...... L ------- ....... L ...... ............. --------- ........ ....... .... --- ---
0.1 1.0
100
APPLIED PRESSURE -
Sample of CLAY, SANDY (CL) NATO' Y UNIT WEIGHT= 102 PCF
From TH-1 AT 9 FEET N X" 7: rr,64 MOISTURE CONTENT= 17.7 %
JOB NO. G-0-3899
Swell Consolidation
Test Results FIG. 3
f
6
5
4
3
2
z
0
U)
z
CL
x
ul
�112
z
0
LU
QR
CL
15
0 -2
-3
-4
_5
-6
-7
-8
N
--------------------- --------------------- ------- ---- - --------- -------------- ---------------------- --------------- ------- ----------------- -------
--------------------- ------- ------- - ------ ------- ........ -----------
........... .... ------ - -------- ------ ------
------------------- - ---------------- -------- ----
------------------------------------ I.- ------ r .... T --------- 1-7.7 --------------------------------- - - ---------- --------------------------- :
------------------ T -------- --------------- ---------
------------ ---------------
----------- .......... -------- --
-.- - -- ------- ---------------------------- I ------------------- -- ------- -------------------
-----------
----------- T -------------------------- --------------------------
------------- ----------------------------- 1 --- 7 ......
CONSTANTEXPANSION UNDER'
PRESSURI DUE TO WETTING
----------- 2 ------- -------------- ---------------------------------- -------- ------ --------------- -----------
--------------------------- .... ------ .......... -----------
-----------
------------------- -------------- ------------------ ----- - ----- -------------------- - ----------------
---------- ........ ...... ----------- ---- ...... ........... ------------------------ ------
---------------
-----------------
------------- I ------------------ ------------- ------------------ ....... -------------- ................. . ............
------------ I,--, ......... ---------- -------------- ----------------- I ........... - --------------------
---------------- ------- ...... ........ ...... -------------------------- --------------------- ------ -----------
0.1
Sample of CLAY, SANDY((
From TH-2 AT 4 FEET
JOB NO. GS-3899
1.0 10 100
APPLIED PRESSURE - KSF
NATURAL DRY UNIT WEIGHT= 106 PCF
NATURAL MOISTURE CON'T.,ENT= 13.1 %
Sweet - nsolidation
T suits FIG. 4
SATURATION AND PREPARATION
DATE: 04/28/03
TIME AT START OF SATURATION: 3:30 pm
PERCOLATION TEST
DATE: 04/30/03
WATER IN BORING AFTER 24 HOURS
_ YES X NO
PERCOLATION TEST RESULTS
HOLE
NUMBER
DEPTH
(INCHES)
TIME AT
START OF
INTERVAL
TIME
INTERVAL
(MINUTES)
DEPTH TO WATER
CHANGE
IN WATER
DEPTH
(INCHES)
PERCOLA-
TION RATE
(MIN/INCH)
START OF
INTERVAL
(INCHES)
END OF
INTERVAL
(INCHES)
P-1
32.0
12:15
30
9.0
9.25
0.25
120
12:45
15
9.25
9.5
0.25
60
1:00
15
9.5
9.75
0.25
60
1:15
30
9.75
10.0
0.25
120
1:45
15
10.0
10.25
0.25
60
2:00
15
10.25
10.25
0.25
60
2:15
15
10.25
10.5
0.25
60
2:30
15
10.5
10.75
0.25
60
2:45
30
10.75
11.0
0.25 �°�
120
3:15
15
11.0
11.25
0.
60
Job No. GS-3899 Fig. 5
SATURATION AND PREPARATION
PERCOLATION TEST
DATE: 04/28/03
TIME AT START OF SATURATION: 3:30 pm
DATE: 04/30/03
WATER IN BORING AFTER 24 HOURS
YES X NO
PERCOLATION TEST RESULTS
HOLE
NUMBER
DEPTH
(INCHES)
TIME AT
START OF
INTERVAL
TIME
INTERVAL
(MINUTES)
DEPTH TO WATER
CHANGE
IN WATER
DEPTH
(INCHES)
PERCOLA-
TION RATE
(MIN/INCH)
START OF
INTERVAL
(INCHES)
END OF
INTERVAL
(INCHES)
P-2
29.0
12:15
15
10.5
10.75
0.25
60
12:30
60
10.75
11.0
0.25
240
1:30
45
11.0
11.25
0.25
180
2:30
30
11.25
11.5
,a0�� �
120
Job No. GS-3899 Fig. 6
SATURATION AND PREPARATION
PERCOLATION TEST
DATE: 04/28/03
TIME AT START OF SATURATION: 3:30 pm
DATE: 04/30/03
WATER IN BORING AFTER 24 HOURS
YES X NO
PERCOLATION TEST RESULTS
HOLE
NUMBER
DEPTH
(INCHES)
TIME AT
START OF
INTERVAL
TIME
INTERVAL
(MINUTES)
DEPTH TO WATER
CHANGE
IN WATER
DEPTH
(INCHES)
PERCOLA-
TION RATE
(MIN/INCH)
START OF
INTERVAL
(INCHES)
END OF
INTERVAL
(INCHES)
P-3
33.0
12:15
15
10.5
11.0
0.5
30
12:30
15
11.0
11.5
0.5
30
12:45
15
11.5
11.75
0.25
60
1:00
15
11.75
12.0
0.25
60
1:15
15
12.0
12.25
0.25
60
1:30
15
12.25
12.5
0.25
60
1:45
15
12.5
12.75
0.25
60
2:00
15
12.75
13.0
0.25
60
2:15
15
13.0
13.25
0.25
60
2:30
15
13.25
13.5
0.25
60
2:45
15
13.5
13.75
0.25
60
3:00
15
13.75
14.0
0. �.
60
3:15
15
14.0
14.25
60
Job No. GS-3899 Fig. 7
°
NOTE
SLOPE DRAIN SHOULD BE AT LEAST 2 INCHES
PER REPORT BELOW BOTTOM OF FOOTING AT THE
--------------
/ HIGHEST POINT AND SLOPE DOWNWARD
~~~-- TO A POSITIVE GRAVITY OUTLET OR TO
A SUMP WHERE WATER CAN BE
l REMOVED BY PUMPING.
\_
BACKF|LL
(oowpnsmow AND \
COMPACTION PER ecponT)-------------
SLOPE
BELOW GRADE WALL
---------------
STRUCTURALLY SUPPORTED
PER
FLOOR SYSTEM
OSHA
ROVIDE PVC SHEETING
GLUED TO FOUNDATION
WALL TO REDUCE
CRAWL SPA E
MOISTURE PENETRATION
COVER GRAVEL WITH
REINFORCING STEEL
PER STRUCTURAL
ENCASE PIPE IN WASHED-'
CONCRETE AGGREGATE
C33, NO. 57 OR NO. 07).
EXTEND GRAVEL TO AT LEAST
1/2 HEIGHT OF FOOTING. .
-------------
------------------
DRAM 2" MINIMUM
O" MINIMUM I --
OR BEYOND 11
SLOPE FROM BOTTOM
OF FOOTING.
(WHICHEVER IS GREATER)
4-INCH DIAMETER PERFORATED
DRAIN PIPE. THE PIPE ,SHOULD
BE LAID IN A TRENCH WITH A
SLOPE RANGE BETWEEN 1/8
INCH AND 1/4 INCH DROP PER
FOOT OF DRAIN.
FOOTING OR PAD
Exterior
��NN����������
� �����.������.�..
���mmNN ��0��~��
�����mm ��°~�m°°
Job No. GS-3899 Fig^8
U)
F-
J
W
w
LL
0
Q
111■IIIIINI�I
��I��
�IIII�I
i�iiii■i�u
0
O
0
0
C
w
0
a
as
0
a
m
.Q
0_
as
c
m
iu
a�
c
m
0
a)
a
3
CO
hi
0
z
ISDS PERMIT # 2 £,
- U W Nbx: a w-. e, S W. U v- X L a R
PHSYSICAL ADDRESS: b Lit ems, yew ��1� Cc ��b2
LEGAL DESCRIPTION: z a i - Z 3 2- cr6 - O(of
MAII,ING ADDRESS: ;r•�-� �� r H t L c w v 1 - CC) rG z 3
TYPE OF DWELLING: SF NUMBER OF BEDROOMS: 3
-...-.r�..ue.a�.r...y...�r�..u�..�.•.a�-a.-�r.�r.�e..a..-,�.ti..-ti...�.-..��c �... y.. a,...ti...�..�-.r��_,�.__,� W_.W W W ..• -•- -•- -•-
TEST HOLES PRE-SOAKED: YES NO
SOIL
TRAE WATER DEPTH INCHES OF FALL RATE PROFILE
mmmmmomm
-
mmmmmmmmm
mmmmmmmmm
mmmmmmmm
mmmmmmmm
mmmmmmmm
mmmmmmmm
mmmmmmmm
mmmmmmmmm
mmmmmmmmmm
TIME TO DROP LAST INCH: PERC RATE:
MINIMUM LEACH FIELD SIZE: MINIMUM SEPTIC TANK SIZE:
COMMENTS: M� D e d to d 1 crr__-
S 1) f i v9 La e , Ls d w -6a 04 t•^-. /o JX-r-o .t/19
ENVIRONMENTAL HEALTH SPECIALIST DATE
September 21, 2004
James Griffith
Griffith Ranch
6148 Upper Cattle Creek Road
Carbondale, CO 81623
RE: AS -BUILT On -site Wastewater System, Caretaker Residence, 3148 Upper Cattle Creek Road
Griffith Ranch, Eagle County Colorado
SE Job No..24091.01 Eagle County Permit No. 2353-04
Dear Mr. Griffith:
Pursuant to Eagle County regulations, this letter and attached drawing provides documentation that the new OWS
system recently installed is in general compliance with the permitted design. Sopris Engineering has performed site
visits to inspect, measure and document the as built conditions of the constructed OWS system. The as -built size and
relative location of the new OWS system components is delineated on the attached drawing. Also attached is the
completed Eagle County document "ISDS Final Inspection Completeness Form". The OWS components have been
installed in accordance with Eagle County Regulations, the design presented in the Sopris Engineering Report and the
design drawing, dated June 8, 2004.
A double compartment, 1250-gallon concrete septic tank system has been installed with an effluent filter in the outlet
sanitary tee. Effluent discharges to a new 930 square foot soil absorption trench system configured for serial
distribution. Each trench was installed level and has an inspection port on the serial end of each trench and each
corner of the field. Adjacent trenches have a horizontal separation of 10-14 feet. The total as -built trench absorption
area is 930 SF, utilizing 60 standard leaching chambers installed in 4 serial trenches 94' long.
OWS Operation and Maintenance
The re establishment of vegetative cover over the field and responsibility for inspection and maintenance of the
system will remain with the Lot Owner or the owners representative. All components of the engineered OWS shall
be inspected on a regular basis and be properly maintained. The system and responsibility for repair and
maintenance of the system will remain with the Owner.
The OWS should require minimal maintenance. Several factors influencing the need for maintenance include: actual
wastewater flows versus design flows, the volume of kitchen/domestic waste (excluding human waste and toilet
paper), excessive household chemicals and other toxic liquids. The tank, absorption field and other system
components should be visually inspected bi-annually for debris, damage, leaks, or other potential problems. In
general, for a properly utilized system, septic tanks should be pumped and inspected every 2 - 4 years. The effluent
filters should be cleaned every six months and at the time of pumping. Absorption fields should be maintained with
suitable cover and kept free of root invasive plants. Positive surface drainage away from the absorption field should
be maintained.
We have forwarded a copy of this letter with attachments to Eagle County Environmental Health Division. Please
retain this copy for your records and As -built documentation use. If you have any questions or need any additional
information, please call.
LLC
er
5`W�I�'MIe_ Suite A3 • Carbondale, CO 81623 • (970) 704-0311 • Fax (970) 704-0313
SOPHIs ENGINEERING 9 LLC civil cons ,t,t,
i
ISDS Permit # S^sue �� Installer Date: Z1
ISDS FINAL INSPECTION
COMPLETENESS FORM
/ Tank is /2SO Gallons, Tank Material Goy _11_zl�l
Tank is located,-,d feet ands%gam-degrees from S
❑ (Permanent landmark)
Tank is located feet andsr�!� f egrees from -.5 ,cvw
❑ (Permanent landmark)
Tank is set level, �nk lids within 8" of finished arade
_-maize of fieldoSquare feet, Units, 3%Lineal feet, Technology So�.�� �c�,�� c�«� 6
lean -out is installed in beftveen tank and house (+1/100 feet)
4-l"T" that goes down 14 inches in the inlet and outlet of the tank. Effluent filter on outle Yes r No
----�Inlet and outlet is sealed with tar tape, rubber gasket etc��
Tank has two compartments with the larger compartment closest to the house
Measure distance and relative direction to field
Depth of field,�.�feet 7
interface raked
Inspection portals at the end of each trench
Proper distance to set -backs
ambers properly installed as per manufacturers specifications. (Chambers latched, end plates
properly installed, rocks removed from trenches, etc.)
Splash plate(s) installed at least in first trench inlet S�v'����.r-� w/ ��✓% �w�G4�
Type of pipe used for building sewer leach field
Other
Inspection meets requirements
Copy form to installer's file if recommendations for improvement were suggested
ACTIONS TAKEN:
AW
W C 0000
n
o (V v
s
c I-
' C3TQ
A
o
0 a
to
40�
fps
YIK
171
Nal.
t A
13
1
•
�a Q
• k 00
cn W
�� o
dt
Cw�
3+
CD
o
N
CJi
O
d
O
7
C2
u I
CD
4
tD * W Q !
tSl
CD N p
NW)
o �p ccn .tom
00
tD C ryen',
Q dA ]JJ
rn� 4! ,
CD
_._ . 3
CD
CD
CD
j'
CQ
N
Rio
OD N r
-a CS7
•
3
N,c�
CD
O
n�
CD
mn
77
`V
ZJ
Q
PROJECT- _ 3148—UUpperXCattle23GRIFFITH
231
Creek Rd., Carbondale, Co
pr
CARE TAKER UNIT
PROJECT
project description nc-y�—
date
task/action
follow-up
start
date
completion
date
i
'tle o b
r
('2$ O
t
•
e- �' � • v •: -� �c w. - U't
(0 0 5 1 �..1 # ., r � i � C , { �r� d
T 5 s . �. ✓
e,» :� x r s i
ppC
l%A_ }0S(� r.n. c 1.dS
lig�-a
4--o 4uu
�2,� 40rr-e,
4-dq{
1
V V
6, (L c, 4 lei
c' 15 13�_-c��k•4v<;eY
' {li,v_
t f
its
�o v
9,. c/
1
PROJECT CONTACTS
name
phone/fax
e-mail
APW
documents enclosed
-�%"y -
notesj,,a - ck vN, \ ' �reAc'tie's
� v t 14-s _�. �_ , 5 d e 1, " � , ' s ,� � f k � t -1 ;,.
94'
®®
GRAPHIC SCALE
10 20 40 80
( IN FEET )
I inch = 20 ft.
4" DIA. SOLID PVC
DISTRIBUTION PIPE
'INSPECTION PORT (TYP.)
INSTALLED 60 INFILTRATOR CHAMBERS IN 4 TRENOIE:
WITH 15 LEACHING CHAMBER IN EACH TRENCH.
TRENCHES MAY BE ADJUSTED AS LONG AS A TOTAL:
OF 930 SO. FT. OF AREA IS PROVIDED. LOCATION
TRENCHES MUST MEET ALL COUNTY SETBACK
REQUIREMENTS. THE SYSTEM SHALL BE PLUMBED FOR
SERIAL DISTRIBUTION. THE CHAMBERS IN EACH
TRENCH SHALL:: BE, INSTALLED AT LEVEL GRADE: ,THE
• BOTTOM ELEVATION ` "OF ` EACH, TRENCFI :MAX VARY TO
ACHIEVE A MAXIMUM DEPTH OF 36 INCHES TO THE
BOTTOM SURFACE BELOW THE PROPOSED GRADE.
4�_
f = ldE.ttoV�'L' 1 fir-., ,; �•tE
� / `'`f �f XIS M �1.� ��. , •� �• � CIO
...�;,..•,��-_� _,:'' f �• ; jt�, ..._ - _ `. "L•-_'
IV
New
For
��drCA � R 1�6' Rana
71
GRIFFITH fCH SITE PLAN
_E 1 "=200'
OWS SYSTEM NOTES
1. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO STATE AND
COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM (ISDS) REGULATIONS.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL
UTILITY COMPANIES FOR FIELD LOCATIONS OF UTILITIES PRIOR TO
CONSTRUCTION AND EXCAVATION,
3. ALL SEWER LINES TO BE SDR-35 OR SCHEDULE 40 P.V.C. PIPE UNLESS
NOTED OTHERWISE.
4. INSTALL A TWO-WAY CLEAN OUT ON THE SERVICE LINE FROM THE HOUSE.
5. THE SEPTIC TANK SHALL BE INSTALLED LEVEL ON COMPACTED EARTH. INSTALL
WATERTIGHT RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS
POINTS TO THE FINISHED SURFACE GRADE. PROVIDE BOUANCY COMPENSATION
IF GROUNDWATER LEVELS WILL RISE ABOVE THE BOTTOM OF THE TANK.
6, A SANITARY BAFFLE TEE IS REQUIRED ON THE SEPTIC TANK INLET AND OUTLET.
TWO WAY CLEAN OUT INSTALL THE INLET AND OUTLET TEES PLUMB AND IN A POSITION TO ALLOW
PROPOSED GRADE EASY INSPECTION AND MAINTAINANCE OF TANK FROM THE TANK RISERS.
FINISH FLOG? � 7• WE RECOMMEND THE INSTALLATION OF A 4" EFFLUENT FILTER CONTAINED IN THE
EXISTING GRADE 4" BAFFLE OUTLET TEE OF THE SEPTIC TANK. THE FILTER SHOULD BE
RISER & LID INSPECTED EVERY SIX MONTHS. THE EFFLUENT FILTER SHALL BE MAINTAINED
AND CLEANED WHEN THE TANK IS PERIODICALLY PUMPED OR AS NECCESSARY.
INSPECTION PORT PROPOS D Sfd0l1 E INSTALL A SUITABLE EXTENSION ON THE FILTER WITH A HANDLE TO BE WITHIN
W/ CAP (TYP. EFFLUENT FILTER OUTLET TEE 6" BELOW THE ACCESS LID.
(NO GLUE) 8. THE CONTRACTOR SHALL ENSURE THAT THE SEWER LINES, SEPTIC TANK AND
RISERS ARE WATERTIGHT. ALL PLUMBING FIXTURES AND OWS COMPONENTS
SHALL BE INSTALLED AND MAINTAINED TO AVOID SURFACE OR GROUNDWATER
FROM ENTERING THE SYSTEM AND TO PREVENT LEAKAGE FROM THE SYSTEM.
IN-HOUSE PLUMBING FIXTURES SHALL BE MAINTAINED TO PREVENT EXCESS
EFFLUENT DRA/V LINE WATER FROM ENTERING THE SEPTIC SYSTEM.
AT MINIMUM 27, SLOPE g, THE DIMENSIONS AND NOTES SHOWN ON THE PLAN INDICATE MINIMUM AREA,
SEPTIC TANK LENGTH, WIDTHS AND SEPARATION DISTANCES FOR THE TRENCHES, BED OR
EFFLUENT DISCHARGE LINE MOUNDED ABSORTTON FIELD.
AT MINIMUM 1% SLOPE 10. THE ABSORPTION TRENCHES SHALL BE EXCAVATED TO LEVEL GRADE IN
SERIAL DISTRIBUTION LINES NATIVE EARTH. STANDARD LEACHING CHAMBERS WILL BE PLACED IN THE
AT MINIMUM 1% SLOPE TRENCHES OVER THE NA71VE SOIL. THE TRENCH BOTTOM AND SIDEWALLS
SHALL BE SCARIFIED AND/OR RACKED IF SMEARING OCCURS.
11. THE LEACHING CHAMBERS SHALL BE INSTALLED LEVEL WITH A MINIMUM
COVER OF 10 INCHES NOT TO EXCEED 24 INCHES AND CONNECTED FOR
SERIAL DISTRIBUTION.
CROSS SECTION SLOPE DETAIL 12. AN APPROPRIATE CHAMBER END PLATE SHALL BE INSTALLED OR A SPLASH
N.T.S. PLATE SHALL BE INSTALLED ON THE TRENCH BOTTOM BELOW EACH TRENCH
INLET TO PREVENT SCOURING. END PLATES SHALL BE INSTALLED ON THE
END CHAMBERS IN EACH TRENCH.
13. VERTICAL INSPECTION PORTS SHALL BE INSTALLED FROM THE CENTER PRE
MARKED HOLE ON THE TOP OF THE SERIAL END CHAMBERS. (TYP. END OF
EACH ROW) THE PORTS MAY HAVE TREADED CAPS AT GRADE.
14. THE CHAMBERS WILL BE BACKFILLED WITH EXCAVATED MATERIAL VOID OF
ROCKS, THE BACKFILL MATERIAL SHALL NOT EXCEED 2 1/2" DIAMETER AND
SHALL BE PLACED TO AT LEAST 6 INCHES ABOVE THE TOP OF THE
CHAMBERS. THE TOP OF THE PLACED BACKFILL SHALL BE COVERED WITH A
LAYER OF FILTER FABRIC. A MINIMUM 4" DEPTH OF TOPSOIL IS TO BE
PLACED ABOVE THE BACKFILL TO THE SURFACE.
15. ALL INSTALLATION OF LEACHING CHAMBERS SHALL BE IN CONFORMANCE
WITH THE MANUFACTURES INSTALLATION INSTRUCTIONS.
16. THE ABSORPTON TRENCHES/BED OR MOUND MUST BE GENERALLY MARKED
AT THE FOUR CORNERS WITH INSPECTION PORTS AND/OR BURIED REBAR.
THE FIELDS MUST BE PROTECTED FROM VEHICULAR AND LIVESTOCK TRAFFIC.
17. THE ABSORPTON FIELD SURFACES MUST BE CROWNED TO DIVERT
SURFACE DRAINAGE AWAY FROM THE MOUNDED FIELD.
NOTE: 18. THE ENTIRE ABSORPTION FIELD SURFACE MUST BE REVEGATATED,
EACH RUN OF CHAMBERS MUST BE LEVEL. INLET AID END
CAP TO BE USED ON EACH END CHAMBER. INSTAL. 4" PVC 19. THE ABSORPTION FIELD SHALL BE INSTALLED PER THE REQUIRED SETBACK
INSPECTION PORT W/ CAP (NON -GLUED) ON END GtAMBERS DISTANCES:
OF EACH TRENCH. MAINTAIN 6' OF UNDISTURBED :OIL 10 feet from any property line.
BETWEEN TRENCHES. THE TRENCH BOTTOM ELEVA70N OF 25 feet from any potable water supply line.
ADJACENT TRENCHES MAY VARY WITH RESPECT TO FINISH 20 feet from any occupied dwelling.
SURFACE ELEVATION AND TO INSURE ADEQUATE OWRFLOW 100 feet from any well, spring or cistern.
DRAINAGE FROM THE PRECEDING SERIAL TRENCH. 50 feet from any stream or water course.
CROWN FIELD TRENCH TO DISTRIBUTION SYSTEM
DIVERT SURFACE WATER
REVEGATATION — 3' MIN 6' MIN 20• EFFLUENT WILL GRAVITY DISCHARGE THROUGH THE OUTLET BAFFLE TEE
TOPSOIL LAYER FROM THE SECONDARY COMPARTMENT OF THE SEPTIC TANK TO THE FIRST
' 7 " SERIAL TRENCH LEACHING CHAMBER, EFFLUENT WILL BE SERIAL
\ " DISTRIBUTED TO THE REMAINING SERIAL ABSORPTION TRENCHES VIA 4"
PERVIOUS MEMEBRANE LAYER _ 4 -12 12"
"\ " OVER FLOW DISTi21BU110N LINES.
FILTER FABRIC OR STRAW = �• �=�`-=t� �••�I•=== :-:. � � - MIN.
0'-"\� 21. THE EFFLUENT WILL DISTRIBUTE OVER THE BOTTOM SURFACE OF THE FIRST
SELECT BACKFILL LAYER a• .'4-•. - fl :.::. • \ AND SUCCEEDING TRENCHES. THE MINIMUM SLOPE OF THE DISCHARGE LINE
NATURAL ONSITE SOILS FREE }� U FROM THE TANK TO THE FIRST TRENCH SHALL BE INSTALLED AT A MINIMUM
29a SLOPE. THE CONNECTING DISTRIBUTION LINES SHALL BE INSTALLED AT
EX GRAVEL AND ROCKS IN Q :'; A . j/\T 12" DISTRIBUTION PIPING, OPE TO T14E I AND OF EACH SERIAL TRENCH.
FITTINGS SHALL BE TIGHT ANLLD
EXCESS OF 2 1/2" DIAMETERA MINIMUM OF
NFILDTRATORA CHAIMBER (TYP.) y� ��\\�j\`��\ INSTALLED TO INSURE DISTRIBUTION THROUGH THE SYSTEM.
SCARIFY/TILL BOTTOM SURFACE TO
A DEPTH OF 3" AND RAKE LEVEL UNDI7URBED SOIL
LEACHING CHAMBER CROSS SECTION DETAL
NTS
24091.01 24091-43-OWS.DWG 8116104
GENERAL NOTES:
1. THE OWS SYSTEM AS SHOWN ON THE PLAN AND THE DETAILS WERE
DESIGNED BY SOPRIS ENGINEERING. THE PROPOSED HOUSE, DRIVEWAY
AND PROPOSED CONTOURS WAS PROVIDED BY THE OWNER. THE
EXISTING LOT CONDITIONS AND SURVEY INFORMATION WAS PROVIDED BY
OTHERS.
2. THE EXISTING CONTOUR INTERVAL ON THIS MAP IS 5 FEET.
N0.1 DAT REVISION I BY
3148 UPPER CATTLE CREEK ROAD
GRIFFITH RANCH, EAGLE COUNTY, CO
CARETAKER HOUSE OWS SYSTEM
AS —BUILT ONSITE WASTEWATER SYSTEM
OPRI5 , LLC. SITE PLN AAND SYSTEM DETAILS
ENGINEERING
VIL CONSULTANT
502 MAIN STREET, SUITE A3 DES. PER CK YTN FILE NO. SHEET I
CARBONDALE, CO 81623
(970) 704-0311 DR. PER DATE 81f6/04 24091.01 OF I
r«
•0-«
r• «
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH
P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631
Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. q 1� 0 9'0'
Please call for final inspection before covering any portion of installed system.
OWNER: James W. Griffith Jr. PHONE: 963-2943
MAILING ADDRESS: 3148 Upper Cattle Creek Rd, Carbondale, CO 81623
AGENT: PHONE:
SYSTEMLOCATION: 3148 Upper Cattle Creek Rd, Carbondale
LICENSED INSTALLER: James Griffith, Jr. LICENSE NO. 4-91
DESIGN ENGINEER OF SYSTEM:
INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING:
1250 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT.
DISPERSAL ARf=A REQUIREMENTS:
SQUARE FEET OF SEEPAGE BED 210 SQUARE FEET OF TRENCH BOTTOM.
SPECIAL REQUIREMENTS: Owner requesting 10" SB2 = 80' of 10" SB2 in trenches. Install
inspection portals at end of trenches.
ENVIRONMENTAL HEALTH OFFICER: 1-11 41�;� -
DATE: 10/8/91
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10.104, C.R.S. 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH
LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM
TO BE LICENSED ACCORDING TO THE REGULATIONS.
FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED
PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION ORDISPERSAL AREA: 340 SQUARE FEET. Y/R IOD of Id .SB2 /
INSTALLED SEPTIC TANK: 1� // GALLONS �40 DEGREES N
S� FEET ?�m AIIV coehier pP aryyAc,/ Z
SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR:
PROPER MATERIALS AND ASSEMBLY YES NO
COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: �� YES NO
ANY ITEM CHECKED NO
REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE
ADE.ARRANGE A RE -INSPECTION WHEN WORKIS COMPETED.
COMMENTS: /S-UIr a I iOo em Aou) *'. /"0//S/Ze, %r a t �e'l*'a
a�al,o.v ems,AFP14-1 15 Stee/ Pr 3 be,4w,- S_ ENVIRONMENTAL HEALTH OFFICER: DATE: // /41_ 9/
ENVIRONMENTAL HEALTH OFFICER: DATE:
(RE -INSPECTION IF NECESSARY)
RETAIN WITH RECEIPT RECORDS PERMIT
APPLICANT/AGENT:
OWNER:
AMOUNT PAID: RECEIPT #: CHECK #: CASHIER:
ISDS Permit # 2_0
Building Permit #
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE- EAGLE COUNTY
P.O. BOX 179
EAGLE, CO 81631
328-8730/927-3823(Basalt)
PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $125.00
**************************************************************************
PROPERTY OWNER: �A IPCMVS
0- / m A¢./ 'F-• O a, F-Fr-rW
MAILING ADDRESS:31,40 kippwa- its GZ"Yap PHONE: C?
APPLICANT/CONTACT PERSON: PHONE: 9 �o3 --'XA
LICENSED SYSTEMS CONTRACTOR: �� 4-Q-11
ADDRESS: PHONE
PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description: -
Parcel Number: Lot size: .,q7 uLax
Physical Address i�f�yon,t z iI.5, �cy-y_, TZO-o
BUILDING TRIPE : - ( Check
( ) Residential /
(-)-Residential /
( ) Commercial /
HOT TUB
WATER CONSERVATION PLAN:
TYPE OF WATER SUPPLY:
Give depth of all
applicable category)
Single Family Number of Bedrooms 2—
Multi-Family* Number of Bedrooms
Industrial* Type
Yes ( ).. No
Yes ( ) No ( )
Well( ) Spring Surface ( )
Public ( ) Name of Supplier:
wells within 200 feet of system: No,v,7
*These systems require design by a Registered Professional Engineer
NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION
MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
SIGNATURE: DATE: f?i
*
�� G C/
AMOUNT PAI RECEIPT#�S S� _ DATE: I�
CHECK # q61 Q CASHIER:
TIME LOG
Travel Perc Final
COMMUNITY DEVELOPMENT
DEPARTMENT
(303) 328-8730
EAGLE COUNTY, COLORADO
November 14, 1991
James W. Griffith Jr.
3148 Upper Cattle Creek Rd
Carbondale, CO 81623
RE: Final of ISDS Permit No. 1090
Dear Mr. Griffith:
725 CHAMBERS AVE.
P.O. BOX 179
EAGLE, COLORADO 81631
FAX (303) 328.7207
This letter is to inform you that the above referenced ISDS
Permit has been inspected and finalized. Enclosed is a copy to
retain for your records. Also enclosed are informational sheets
regarding the care of your septic system.
If you have any questions regarding this permit, please contact
the Eagle County Environmental Health Division, P.O. Box 179,
Eagle, Colorado 81631. We can also be reached, depending on your
calling area, at the following numbers: Eagle Valley 328-8730;
Basalt/El Jebel 927-3823.
Sincerely,
C. Kelley Carhart
Office Assistant
ckc
Encl: Information Sheets
Final ISDS Permit
cc: Chrono File
ISDS File
Building Permit File
ni
Y3 - 7`7
G.t-v0� ► 4s C�� v MSt
V)W 9 4
ISDS PERMIT # AM&O
PERCOLATION TEST
EAGLE COUNTY ENVIRONMENTAL HEALTH DEPT.
OWNER: �
LEGAL DESCRIPTION:3%z/9 U9b��,A, A/
MAILING ADDRESS:
TYPE OF DWELLING: 5F/ ,, NUMBER OF BEDROOMS
TEST HOLES PRE-SOAKED: YES NO
TTMF. nv VAT T nitM"
1
2
3
1
2
3
1
2
3
1
2
3
0,
1
05
0(,
07
11.5
I1.0
1 17,25
4.375
Z.875
3.5
/D
/I
iZ
I'}b
I�,�j
7 D•D
2.5
1 1.5
2.75
Z.
3.3
I.$
3�
/_5
l�
�%
16.0
A-0
�1 75
2.0
1.5
1.75
2.5
3.3
21
4
Zo
16,%75
15.0
17-6
1'75
1.0
.75
15.7
5
4.7
s
y5
zG
11,0
16,D
7q,0
I. i2-5
I5
1.5
L1q
3.3
3,3
161
31)
3)
3
1�.315
17.5
z�{5
1.375
l 0
5
3b
S
to
71 "
35�,5
2.s,5
r 1.75
1.0
1.0
4.7
5
5
$
1.0
1.0
%
_ 1 /Pf•.s7 /i/O.//
II
zz,o
zo.75
27,p
5
1.25
.5
/
Z/
l6
Time to drop last inch S /o-�S
J / I'vo
PERC RATE: ,j MINIMUM SEPTIC TANK SIZE: rlla/�ta- J�J N20
MINIMUM LEACH FI/ELD SIZE: jo/ RZ1 oviow r�ve�t� /p'sg2- s 70' � ��56z 1_4 7ift e5
COMMENTS: 1ns •r �/ 14197ee 1111 .r %a j�S dry/ fyerc%LP�.
PERC TEST DONEAY:1 _A'�3
r
�/� 9�
DATE:
EnViX'onmeAtal Health Officer
rev. 6/90ks _I=
X ZD/ I
ri
vi
�r
1
Zli,w 5;
J
,op
S4' r�
i
N
-act q-a
L4 a'1z
DIAMOND G RANCH
Jarnes W. Griffith, Jr.
3148 Upper Cattle Creek Road
Carbondale, Colorado 81623
303-963-2943
�
To Date - t
n"0,4 M 4V4
Subject 2
Anxf-4' -D *51 (- -i
I N oq
. .. . ..... (kAj
c-
21 -.AJ
-x Lz
Ls iv n"v
,�. J
L. o i tN4 LILL-��'Dowj
-v t Ino -a L q T- -4 4-V)
-T
T-
V
C ov
THE
co".'Ji wr
DIAMOND G RANCH
James W. Griffith, Jr.
3148 UPPer Cattle Creek Road
Carbondale, Colorado 81623
303-963-2943
To C Date -Lo - 1 ---01 1
Subject Se%nc-
%0Q
-PCRIA-Sig F�o IN
r) t'r pi
C,A,o lijer-_ L,0 C_ArT. eL-V\A V, AefV-- CIO 4'.." *-e-
of" T"
-D- ' v
ou e-n,
?0, N PAQ03 I -VA
THE WRJTKwfu Co. RX&R4.41, IN 4nm4jl1
RECEIVED
OCT 0 1 10
EAGLE COUNTY
COMMUNITY DEVELOPMENT
ol
Chen € Northern, i nc.
G �osullmcl Umprieos alml scienlisis
XX
SUBSOIL SZUDY
FOR FOUNDATION DESIGN
/ PROPOSED RESIDENCE
3148 UPPER CATTLE CREEK ROAD
p \ yG&RFfD OO M Y, COIARADO
Job No. 4 300 90
Prepared For:
Jim and Mary Griffith
3148 Upper Cattle Creek Road
Carbondale CO 81623-9748
W
5080 Rued 154
Glenwood SpriNls. Colorado 81601
303 945.7459
303 946.2363 Facsimile
May 15, 1990
TABLE OF 00KI12't5
CONCLUSION
PURPOSE AND SOOPE OF STUDY
PROPOSED OONSTRUCTION
SITE CONDITION
FIELD EXPLORATION
SUBSOIL CONDITIONS
FOUNDATION RECOMMENDATIONS
FLOOR SLABS
UNDERDRAIN SYSTEM
SURFACE DRAINAGE
LI=ATIONS
FIGURE 1
- LOCATION OF EXPLORATORY BOR iGS
FIGURE 2
- LOGS OF EXPLORATORY BORINGS
FIGURE 3
- LEGEND AND NOTES
FIGURE 4
- SWELL -CONSOLIDATION TEST RESULTS.,'
FIGURE 5
- GRADATION TFST RESULT'S
TABLE I
- SUMMARY OF LABORATORY TEST RESULTS
1
1
2
2
2
3
4
5
5
6
7
CONCLUSIONS
The proposed residence should be founded with spread footings
bearing on the natural granular so ls'�and designed for an allowable
soil bearing pressure of 2000 psf. Other design and construction
criteria relating to geotechnical aspects of the proposed residence
are presented in the body of the report.
..•. •• • s
This report presents the results of a subsoil study for a proposed
residence to be located at 3148 Upper Cattle Creek Road, Garfield County,
Colorado. The project site is shown on Fig. 1. The study was conducted in
accordance with our agreement for geotechnical engineering services to Jim and
Mary Griffith, dated April 3, 1990.
A field exploration program consisting of exploratory borings was
conducted to obtain information on subsurface conditions. Samples obtained
during the field exploration were tested in the laboratory to determine their
engineering characteristics. The results of the field exploration and
laboratory testing were analyzed to develop recommendations for foundation
types, depths and allowable pressures for the proposed building foundation. The
results of the field exploration and laboratory testing are presented in the
report.
This report has been prepared to summarize the data obtained during this
study and to present our conclusions and recommendations based on the proposed
construction and the subsoil conditions encountered. Design parameters and a
discussion of geotechnical engineering considerations related to construction
of the proposed residence are included in the report.
W
PROPOSED OONSINXTION
The proposed 5000 square foot residence will be one story of wood I.ame
construction with an attached garage. Ground floor will either be slab -on -grade
or structural over a crawl space. Grading for the structure is expected to be
relatively minor with cut depths between about 6 to 8 feet. We. -assume
relatively light foundation loadings, typical of the proposed type. construction.
If building loadings, location or grading plans change significantly from
those described above, we should be notified to reevaluate the reccMrendations
contained in this report.
SITE OONDITIONS
The proposed building area is located on a west facing hillside. The
topography of the area is generally flat with slopes of 7% to 10% down to the
west. An existing gravel road is located to the north of the building area.
The road leads to an existing two-story wood frame house located about 300 feet
east of the proposed building area. There is an, existing pond reportedly about
8 feet deep located south of the existing house. A drainage swale runs from the
pond area down to the south of the proposed building area. The building area
is vegetated with grass. There are willows and brush along the drainage swale
to the south.
oil 0*'X�CO)IVZB V •
The field exploration for the project was conducted on April 4, 1990.
Two exploratory borings were drilled at the locations Shawn on Fig. 1 to
evaluate the subsurface conditions. The borings were advanced with 4-inch
diameter continuous flight augers powered by a truck mounted CME-55 drill rig.
The borings were logged by a representative of Chen -Northern, Inc.
-3-
Samples-of the subsoils were taken with 1 3/8-inch and 2-inch I.D. spoon
samplers. The samplers were driven into the subsoils at various depths with
blows from a 140 pound hammer falling 30 inches. This test is similar to the
standard penetration test described by ASIM Method D-1586. The penetration
resistance values are an indication of the relative density or consistency of
the subsoils. Depths at which the samples were taken and the. penetration
resistance values are shown on the Logs of Exploratory Borings, Fig. 2. The
samples were returned to our laboratory for review by the project engineer and
testing.
i
The subsoil conditions encountered at the site are shown graphically on
Fig. 2. The subsoils consist of 4 1/2 to 5 feet of topsoil overlying 5 1/2 to
7 1/2 feet of relatively dense, clayey sandy gravels containing cobbles and
boulders.
Very stiff to hard sandy silty clay
with occasional
gravel and
cobbles was
encountered below depths of 10 1/2 to
12 feet down to
the maxir=
depth explored, 21 feet.
laboratory testing performed on samples obtained from the borings included
natural moisture content, density, gradation analyses and Atterberg limits
testing. Swell -consolidation tests results,.,shown on Fig. 4, indicate that the
upper organic topsoil is highly compressible. The lower sandy clays have low
to moderate compressibility. Results of a gradation analysis performed on small
diameter drive samples (minus 1 1/2-inch fraction) of the natural granular soils
are shown on Fig. 5. Atterberg limits testing indicates the clay fraction of
the subsoils is of medium plasticity. The laboratory testing is summarized in
Table I.
-4-
No free water was encountered in the borings at the time of drilling or <
when checked two days later. The subsoils were generally moist.
FORMTION REOOMMENDATIONS
Considering the subsoil conditions encountered in the exPloratory borings
and the nature of the proposed construction, we recomwnd the residence be
founded with spread footings bearing on the natural granular soils below all
topsoil. The building foundation excavation may extetxd into the underlying
clays. We expect bearing on the clays will be acceptable.
The design and construction criteria presented below should be observed
for a spread footing foundation system. The construction criteria should be
considered when preparing project documents.
1) Footings placed on the undisturbed natural granular soils should be
designed for an allowable soil bearing pressure of 2000 psf. Based on
experience, we expect settlement of footings designed and constructed as
discussed in this section will be about l inch or less.
2) All existing fill, topsoil and any loose or disturbed soils should be
removed and the footing bearing level extended down to relatively dense
natural granular soils.
3) The footings should have a minimum width of 16 inches for continuous walls
and 2 feet for isolated pads.
4) Exterior footings and footings beneath unheated areas should be provided
with adequate soil cover above their bearing elevation for frost
protection. placement of foundations at least 36 inches below exterior
grade is typically used in this area.
5) Continuous foundation walls should be reinforced top and bottom to span
an unsupported length of at least 10 feet. Foundation walls acting as
-5
retaining structures should also be designed to resist a lateral earth
pressure corresponding to an equivalent fluid unit weight of 50 pcf.
G) A representative of the soil engineer should observe all footing
excavations prior to concrete placement to evaluate bearing conditions.
The natural on -site soils, exclusive of.topsoil, are suitable to support
lightly to moderately loaded slab -on -grade construction. TO reduce the effects
of some differential movement, floor slabs should be separated from all bearing
walls and columns with expansion joints which allow unrestrained vertical
movement. Floor slab control joints should be used to reduce damage due to
shrinkage cracking. The requirements for joint spacing and'slab reinforcement
should be established by the designer based on experience and the interned slab
use. A minimum 4-inch layer of free -draining gravel should be placed beneath
basement level slabs to facilitate drainage. This material should consist of
Minus 2-inch aggregate with less than 50% passing the No. 4 sieve and less than
2% passing the No. 200 sieve.
All fill materials for support of floor slabs should be compacted to at
least 95% of maximum standard proctor density at a moisture content near
Optimum- Required fill can consist of the on -site gravels devoid of vegetation,
topsoil and oversized rock.
DI V Di
Although free water was not encountered during our exploration, it has
been our experience in mountainous areas that local perdu d groundwater may
develop during times of heavy precipitation or seasonal runoff. Frozen ground
during spring runoff can create a perched condition. We recommend below grade
construction, such as retaining walls, crawl space and basement areas be
Protected from wetting and hydrostatic pressure buildup by an undezdrain system.
The drains should consist of drain tile placed in the bottom of the wall
backfill surrounded above the invert level with free -draining granular material.
The drain should be placed at least 1 foot. below lowest adjacent finish grade
and sloped at a minimum 1% to a suitable gravity outlet. Free -draining granular
material used in the underdrain system should contain less than 2% passing the
No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of
2 inches. The drain gravel backfill should be at least 2 feet deep.
The following drainage precautions should be observed during construction
and maintained at all times after the residence has been ccupleted:
1)' Inundation of the foundation excavations and underslab areas should be
avoided during construction.
2) Exterior backfill should be adjusted to near optimum moisture and
compacted
to
at least 95% of the maximcnn
standard proctor density in
pavement
and
slab areas and to at
least 90% of the maximum standard
Proctor density in landscape areas.
3) The ground surface surrounding the exterior of the building should be
sloped to drain away from the foundation in all directions. We recommend
a minimum slope of 12 inches in the first 10 feet in unpaved areas and a
minimum slope of 3 inches in the first 10 feet in paved areas. Free -
draining wall backfill should be capped with about 2 feet of the on -site
soils to reduce surface water infiltration.
4) Roof dawmPouts and drains should discharge well beyond the limits of all
backfill.
-7-
•LINIITATIONS
This report has been prepared in accordance with generally accepted soil
and foundation engineering practices in this area for use by the client for
design purposes. The conclusions and recommendations submitted in this report
are based upon the data cbtained from the exploratory borings drilled at the
locations indicated on Fig. 1 and the proposed type of construction. The nature
and extent of subsurface variations across the site may not become evident until
excavation is performed. If during construction, fill, soil, rock or water
conditions appear to be different from those described herein, this office
should be advised at once so reevaluation of the recommendations may be made.
We recommend on -site observation of excavations and foundation bearing strata
and testing of structural fill by a representative of the soil engineer.
Sincerely,
CF I NORMMN, INC.
By.
Daniel E. Hardin, P.E.
Reviewed By
Steven L. Pawlak, P.E.
DEH,/ec
cc: Morter Architects, Attn: Jim Morter
IJ
00
� r �
.000
1
BORING I
PROPOSED '� / _ i
BUILDING —J /
AREA 000,�
ro
el
IN 44
BORIN 2 /
cp
\ /
_—
\\�,; J� APPROXIMATE SCALE
EXISTING POND rvl /
8' DEEP ��--"� _ EXISTING HOUSE
100,
�J
14 500 90 1 ChenONorthern,Inc I LOCATION OF EXPLORATORY BORINGS I Fig. I
LCUGIVU.
® Topsoil; organic sandy clay, silty, slightly gravelly, occasional cob
to medium stiff, moist, dark brown to black, tiles, soft
© Clay (CL); silty, sandy, with occasional gravel and cobble -size basalt fragments,
very stiff to hard, moist, reddish brown.
rrRmyj Gravel. (GC) and cobbles, clayey, sandy, subangular basalt fragments, dense
moist, brown. ,
Relatively undisturbed drive sample; 2-inch I.D. California liner sample.
Drive sample; standard penetration test (SPT), 1 3/8-inch I.D. split spoon
sample, ASTM D-1586.
5/12 Drive sample blow count; indicates that 5 blows of a 140-pound hammer falling
30 inches were required to drive the California or. SPT sampler 12 inches.
NOTES:
1. Exploratory borings were drilled on April 4, 1990 with a 4-inch diameter
continuous flight power auger.
2. Locations of exploratory borings were measured approximately by pacing from
features shown on the site plan provided.
3. Elevations of exploratory borings were obtained by interpolation between c
on the site plan provided.
4. The exploratory boring locations and elevations should be considered accurate
only to the degree implied by the method used.
5. The lines between materials shown on the exploratory boring logs represent the
approximate boundaries between material ;,,apes and transitions may:;be gradual.
6. No free 4f:.;er was encountered in the bor:=gs at the time of drilling or when
checked k,wo days later. Fluctuations in water level may occur with time.
7. Laboratory Tasting Results:
WC = Water Cootent (%)
DD = Dry Density (pcf)
+4 = Percent retained on No. 4 sieve
-200 = Percent passing No. 200 sieve
LL = Liquid Limit (%)
PI = Plasticity Index (%)
4 300 90 1 ChenoNortheM,Inc Legend and Notes
Fig. 3
Boring
1
Boring
2
Elev. =
66'
Elev. =
74'
4
75
-
75
G
70
OV
IV
WC123
70
DD=99
0.
50/3
65
0�
10/25
65
5/12
.;
a)
DD=84
LL=344
+�
a,
PI=17LL-
v
60
o0
31/12
0
60
+'
>
°o
+4=63
=200=11
17/ 12
WC=24
a,
;•
.o
DD=102
>
a,
w
do
w
55
o.
•�
o;
40/12
.00
55
20/12
50
30/12
50
a5
45
Note: Explanation of symbols presented on Fig. 3.
4 300 90, J -ChenONOrthern,Inc Logs of Exploratory Borings Fig. 2
0
0 1
E 2
O
U
3
4
5
6
7
8
Ehl.,111111IM111Moisture
Content 23 percent
Moll
11111MIllBoring
■■IlilIIl■■1111111■■Illllu,
��111111��■1111111■■11111�,
■■I�IIIIEs��Il�IIII■■Illllh
■■1
11111111il.1111111
■■11��lll��lllllll����i��il
■�11
il�■�imu■■�nmi
�■INIII�■1�11111■■Illllgl
9L
0.1
Z 0
i
3
1 lu
APPLIED PRESSURE — ksf
1uu
Moisture Content 24 percent
Dry Unit Weight 102 pc1
Sampleof: sandy clay
From: Boring 2 at 15 feet
oil
■■uu��■�mm■■��ma
U.) Lu lu luu
APPLIED PRESSURE — ksf
4 300 90 1 Chen -Northern, Inc. I SWELL -CONSOLIDATION TEST RESULTS I Fig. 4
CA-1-79
NIIIIIIIIIIIIIIIIII�1
�
11NIIIIIIIIIIIIIIIIII
■
11111111111111111111111
VIIIIIIIIIIIIII�1111
��
�11111111111111111111�
1
1111111111111111111■
0
c
D
m
O
m
m
m
m
c
r
Ch
.Pb
o-
1090-91 J4-
JOB NAM1 IL � `z4 JosNo.
JOB LOCATION
BILL TO
DATE STARTED
DATE COMPLETED
DATE BILLED
JOB COST SUMMARY
TOTAL SELLING PRICE
ZY__ I
A
'� :✓. I
�+(
f
mall
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOIAER Product 278 ®® NEW ENC * s
//- /3 - 9/
'OLDER
Printed in U.S.A,
b
y
k —f.
f 7 �
T ll
+j( 1
=J ti
O
,
I
r I AiiTi1T' 16
z �
-O i
v e
i
}
�1
^r
r
T�
�I
�► i
q :. I: :.::.::.:.:.::.: J
1 iLL
s ,03
n I N n '. ..:.•. :•.� ..•.:,...em.�.s�.
4000
;:..`...:•: : •• " I .•._..• . '...".: . i
L w
II -77
•. ..•..•....•.•.•.•.. •.•..•..•.. -------------
L
! •i
I
0 �' : :=
aX.
i
.
1 . z. L-
"�»t-
� � \ I „ f. \✓ it _ :�•`�-sue::; ' �-XI�TEi, � Eta
r
r
7; Ton
is :•:•i 1
't27 rtEtA4a4N
4W,
1b
\ HIGH 1-•IATC-c � Rip up.P)- J
94
1 l �
F
�J
.....
W
C
,z,� '�
LU
_
cc
=
O,
cn
<
J
o
Q
J
cn
z
0
V
Q
a
E--
o
a
o
Q...
LL
L
a
M
m
cc
Cc
L
CC
cc)
�
<
v
UJ
J
M
°
of 2 2 •sheets
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
Eagle County Department of Environmental Health PERMIT N2 0876
P.O. Box 850 - 550 Broadway
Eagle, Colorado 81631
Telephone: 328-7311 or 949-5257 or 927-3823
YELLOW COPY OF PERMIT MUST PLEASE CALL FOR FINAL INSPECTION BEFORE
BE POSTED AT INSTALLATION SITE COVERING ANY PORTION OF INSTALLED SYSTEM
Owner: James W. Griffith, Jr. Telephone: 963-2943
Address: 3148 Upper Cattle Creek Road Carbondale, CO 81623
System Location: Same
>M6AM Installer: Andy Schwal l er - Divide Corporation License Number:
Conditional installation approval is hereby granted for the following:
Minimum requirements: 1�0 0 Gallon Septic Tank or Aerated Treatment unit
Absorption area of dispersal area computed as follows:
Percolation rate:_ Inch in Minutes
Absorption area per bedroom Sq. Ft.
Number of Bedrooms 3 X Sq. Ft. minimum requirement per bedroom -
equals Total Sq. Ft. minimum requirement
Special Requirements: Minimum 1000 gallon septic tank- 24n fppt of in" SR 2 equals two (2 )
oot lengths of 10" SB 2 with a diver
Date: 9-26-88 Environmental Health Officer:- Sid Fox
CONDITIONS:
1. All installations must comply with all requirements of the Eagle County Individual Sewage Disposal System
Regulations, adopted pursuant to authority granted in 25710-104, C.R.S. 1973, as amended.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building
requirements. Connection to or use with any dwelling or structure not approved by the zoning and building
departments shall automatically be a violation of a requirement of the permit and cause for both legal action and
revocation of the permit.
3. Section III, 3.21 requires any person who constructs, alters or installs an Individual Sewage Disposal System to
be licensed according to the regulations.
FINAL APPROVAL OF SYSTEM:
No system shall be deemed to be in compliance with the Eagle County Individual Sewage Disposal System
Regulations until the system is approved prior to covering any portion of the system.
I11}l�!}� 8F 1b'S
INSTALLED ABSORPTION OR DISPERSAL AREA: q0 - Q. FT.
INSTALLED SEPTIC TANK: 000 GALLONS; DEGREES; FEET
DESIGN ENGINEER OF SYSTEM: __ Also biC b ea- (� /Z i ^►
INSTALLER OF SYSTEM: _b Iyi PI ((22 - S( SZh(JJA-110-d PHONE:.
SEPTIC TANK CLEANOUT TO WITHIN 12"OF FINAL GRADE OR /
AERATED ACCESS PORTS ABOVE GRADE: YESy NO
PROPER MATERIALS AND ASSEMBLY: YES i✓ NO
COMPLIANCE WITH PERMIT REQUIREMENTS: YES NO
COMPLIANCE WITH COUNTY / STATE REGULATION REQUIREMENTS: YES �NO
COMMENTS:
(Any item checked NO requires correction before final approval of system is made. Arrange a re -inspection when
work is completed.)
DATE (Final Approval) ENVIRONMENTAL HEALTH OFFICER
DATE (Re -Inspection) ENVIRONMENTAL HEALTH OFFICER:
RETAIN WITH RECEIPT RECORDS PERMIT
Name of Applicant: James W. Griffith, Jr. Name of Owner: Same
Amount Paid: $275.00 Receipt Number: 399 Date: 9-6-88 Cashier: J . Brophy
Checks 2027 and 2028
White and Pink Copies - Environmental Health Department Yellow Copy - Applicant / Owner
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT \
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY No. 3 230 \
P. 0. BOX 179
EAGLE, COLORADO 81631
949-5257 Vail 328-7311 Eagle 927-3823 Basalt
PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $125.00
NAME OF OWNER: TRrr1em W . Gv. .,'r+Tk
MAILING ADDRESS: 31%48 Upj2y,g C*mg� C+effyy_ T,-xro PHONE: 963 -a S 51.3
NAME OF APPLICANT (If different from owner): - -
ADDRESS: PHONE:
DESIGN ENGINEER OF SYSTEM (If applicable):
ADDRESS: PHONE:
PERSON RICENSEDBINSTALLERSTA(LAjIOESOF SY(<):NO jVjZWin- Ea e . u.1Lvo 5ctwq 1ra
ADDRESS: 1716 Emma 200P'►SYt,.-r, Q 4162/ 9PHONE: 927- 50?-
PERMIT APPLICATION IS FOR: (X() NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Physical Address: Z) 4IyPPave CAj rLs-( �c e*-x Kv,%O Ca*LJ%0rA&,.1X' CO eL6a3
Parcel Number: Lot Size:
Legal Description: 5eaF A-rrau.F,jn
BUILDING OR SERVICE TYPE (Check applicable category):
x' Residential - Single Family ( ) Residential - Fourplex
( ) Residential - Duplex ( ) Commercial (Type)
( ) Residential - Triplex
NUMBER OF PERSONS: I NUMBER OF BEDROOMS: 3
WASTE TYPES Check applicable categories):
Commercial or Institutional (X) Dwelling
( ) Non -Domestic Wastes ( ) Transient Use
( X ) Garbage Disposal ( x) Dishwasher
( X) Automatic Washer ( ) Spa Tub
( ) Other (Specify):
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
k Septic Tank Composting Toilet ( ) Incineration Toilet
( ) Vault Privy ( ) Greywater ( ) Chemical Toilet
( ) Pit Privy ( ) Aeration Plant ( ) Recycling, Portable Use
( ) Other ( ) Recycling, Other Use
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE: ( ) YES ( X) NO
IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY: (X) YES ( ) NO
WATER CONSERVATION PLAN: ( ) YES NO
NOTE: The Environmental Health Office may reduce the required absorption area upon
approval of an adequate water conservation plan.
SOURCE AND TYPE OF WATER SUPPLY: ( V) Well ( ) Spring ( ) Creek/Stream
Give depth of all wells within 200 feet of system: ,5rr,&ft � war,., q"1 - 45011177O 6
If supplied by�comm nity water, give name of supplier:
SIGANTURE: DATE: 9006®
INFORMATION BELOW TO BE FILLED OUT BY ENVIRONMENTAL HEALTH OFFICER:
GROUND CONDITIONS: Percent ground slope 5170
SOIL
Depth to Bedrock (Per 8' profile hole) plC
Depth to Groundwater table Ole_
PERCOLATION TEST RESULTS: _ Minutes per inch in Hole#1
Q0 rM P,� Minutes per inch in Hole #2
)qo`Z-ir- Minutes per inch in Hole #3
FINAL DISPOSAL BY:
( ) Absorption Trench, Bed or Pit ( ) Evapotranspiration
( ) Above Ground Dispersal ( ) Sand Filter
( ) Under Ground Dispersal �® �( ) Wastewater Pond
( ) Other C8
AMOUNT PAID: �_ RECET NUMBER DATE:
NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION.
(Environmental Health Dept. - Rev. 4/88)
PERCOLATION TEST
ENVIRONMENTAL HEALTH DEPARTMENT
Eagle County
FEE: $125.00 ISDS APPLICATION NO. 3 -a 3C�'
OWNER:
LEGAL DESCRIPTION:
RURAL ADDRESS:
TYPE OF DWELLING:
e!M
NUMBER OF BEDROOMS:
DATE OF PERCOLATION TEST: 2-2-2 TYPE OF SOIL:
TEST HOLES PRE-SOAKED: YES, NO
TIME
WATER DEPTH
INCHES OF FALL
RATE
1
2
3
11
2
3
1
2
3
1
2
3
d3 7,4
1
`
:'5
/irS
3'l8r2e
3
PERCOLATION RATE: jW1 P-1
RECOMMENDED MINIMUM SEPTIC TANK SIZE: 1 0 0 c)
RECOMMENDED MINIMUM LEACH FIELD SIZE:
Vff __
RECOMMENDED MINIMUM SQUARE FOOTAGE PER BEDROOM: 7 X
SITE HAS BEEN REVIEWED AND TESTED FOR PERCOLATION RATE.
Environmental Health Officer Date
COMMENTS: I70' X 2 Val I dou-coenes. y,^
C w, S
Rev. 5/31/84
EAGLE COUNTY ENVIRONMENTAL HEALTH OFFICE
sim Griffith jr.
Name
• B2.30
Date Routed Application No.
Location
Please review the attached Individual Sewage Disposal System Permit Application and
return it with this completed form the the Environmental Health Office.
PLANNING: Complies with - YES NO REVIEWED BY DATE
Subdivision Regulations: NIA
Zoning Regulations: �0
Recommend Approval:. ✓
COMMENTS:
BUILDING: Complies with -
Building Permit Applied For:
Buildina Permit Issued:
Recommend Approval:
COMMENTS:
ENGINEER: Complies with -
Roads:
Grading:
Drainage:
Recommend Approval:
COMMENTS:
YES NO REVIEWED BY DATE
v
q7_�
YES NO REVIEWED BY DATE
ENVIRONMENTAL HEALTH: Complies with - YES NO REVIEUED BY Q4TE
Floodplain Permit Necessary:
I.S.D.S. Regs. Compliance:
Recommend Approval:
COMMENTS: J'1101Ov& ( C300 GA- t 00 STPT
o-F to"' 562. �a
Qtje+1,S 0
JOB NAME
JOB NO. XIL
JOB LOCATION
BILL TO
DATE STARTED
3 �}S upper Cates Of)
Ca bur
DATE COMPLETED I DATE BILLED
JOB COST SUMMARY
TOTAL SELLING PRICE
TOTAL MATERIAL
PERMIT # 876
OWNER: James W. Griffiths, Jr.
LOCATION: 3148 Upper Cattle Creek Road, Carbondale
INSTALLER: Andy Schwaller- Divide Corporation
SIZE OF TANK: 1000 Gallons
DWELLING: 3 BR Residence
PERC RATE: 40 MPI
ABSORPTION AREA: 240 Lineal feet of SB2 10"
FINALIZED: 10-5-88 BY: Sid Fox
10B
r /
_E LLD:
1
S)OWINCA RANCH ROAD
J E XIST I NGa STREAM
EXISTING POWER POLE-
1
-27
O4' �
dj
a $ z I 1ct
SC' �
i
- I
PROPOSED WELL i
LOCATION
SITE PLAN...FOR-
CARETAKERS HOUSE
APMESS:E A OWNS
OWNER: JAMES W. GRIFFITH JR.
ADDRESS:3148 UPPER CATTLE CREEK ROAD
CARBONDALECO. a l Ga
TELEPHONE NO.: - 9lb3. 2945
1 COUNTY: E-AcaLE
SITE SW Y4 OF THE SW Y4 , SECTION ?-3
LOCATION ' TWP. ? S RW-L 87 W G P M.
MIST FROM SECTION LINES • c=' FT. FROM SOUTH SEC. UNE
TO CTR. PT. OF "OUSE ' S (o0i FT. FROM WEST SEC. U E
DRAFTSMh,WI . PHILL1P MICRA.S . PAYNE
ADDRESS ; SAME A OWNER
TELEPHONE ' MO. 303 - 9,03 - 2943
DATE-: 9 _ $ _ ...
SGAt_E : 1 n ._� IO` _
SHEET p1= i
EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH
PLEASE CALL FOR FINAL P. 0. Box 850 - 550 Broadway PERMIT MUST BE POSTED
INSPECTION BEFORE COVERING Eagle, Colorado 81631 AT INSTALLATION SITE
ANY PORTION OF INSTALLED SYSTEM
328-7311 or 949-5257 or 927-3823 PERMIT NO. No- 55 1
OWNER: William Hignett ADDRESS: P.O. Box B, Aspen, CO 81611
SYSTEM LOCATION:
Lot 92, Blue Creek Ranch Subdivision
LICENSED INSTALLER: owner will be responsible as installer is Not LICENSE NUMBER:
**CONDITIONAL INSTALLATION APPROVAL is hereb licensed
y granted for the following:
MINIMUM REQUIREMENTS:1,000 gallon septic tank or aerated treatment unit.
Absorption area or dispersal area computed as follows:
PERCOLATION RATE: 1 inch in 10 minutes.
Absorption Area
per Bedroom
200
sq. ft.
No. of Bedrooms
3 x 200
sq.
ft. minimum requirement per bedroom
600
total sq. ft. minimum requirement.
SPECIAL REQUIREMENTS: This 1'SDS° was engi'nee G"i=ed T p engineAr desigp must be
followed for installation.
DATE: November 18, 1981 INSPECTOR: Erik W. Edeen
**CONDITIONS:
1. All installation must comply with all requirements of the County Individual Sewage
Disposal System Regulations, adopted pursuant to authority granted in 25-10-104,
C.R.S. 1973, as amended.
2. This permit is valid only for connection to structures which have fully complied
with County zoning and building requirements. Connection to or use with any
dwelling or structure not approved by the building and zoning departments shall
automatically be a violation of a requirement of the permit and cause for both
legal action and revocation of the permit.
3. Section III, 3.21 requires any person who constructs, alters, or installs an
individual sewage disposal system to be licensed according to the Regulations.
FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Eagle
County Individual Sewage Disposal System Regulations until the installed system is
approved prior to covering any part.
Installed Absorption or Dispersal Area: sq. ft.
Installed Septic Tank: gallons.�o���
Design Engineer of Syst . &eZ"`- 4 1�
Installer of System: r�r-/j ,— Phone:
Septic tank cleanout to within 12" of final ade or
aerated access ports above grade? Yes No _
Proper materials and assembly? Yes fie'
Compliance with permit requirements? Yes No
Compliance with County/State regulations requirements? Yes No
COMMENTS:
(Any item checked "No" requires correction before final approval of system is made.
Arrange a re -inspection when work is completed.)
DATE: //- 1% -/ INSPECTOR:
RF-TN-PFrTTnN nATF• TNCPP Tn p
PLEASE RMIRM THIS POP.TInN 141TH YnUR SITE PLAN AND FEE(S)
,,28--7311 949- 5 57 7 - 3
• r M EN V I ROEIaT 1L HE„L i H
BOX 850
EAGLE, COLORADO 81631
PER1'1IT FEE _ $150 PERCOLATION TEST FEE = S50
APPLICATION FOR INDIVIDUAL SE'. -'!AGE DISPOSAL SYSTEM PER111T
NO. Z/y
NAME OF OWNER: MQ, C-,hie=
ADDRESS: FIN rp NSPew -Co. &Hail PHIWIE: 92S-4S7'7_—
NAMI OF APPLICANT (IF DIFFERENT FROM O1,lNER):
ADDRESS
DESIGN ENGINEER OF SYSTEM (IF APPLICABLE):
PHONE:
ADDRESS: 4012 S. ggLkwo 5p, �..Tr A-% C�L6Nc���a0 g�(�PH0NE: _94<&.� ZpgZt
PERSON RESPONSIBLE FOR INSTALLATION OF SYSTEM: ��_d►����.,t A�o_'TC�I.�P�1J,�S
ADDRESS: / PHONE.
PERMIT APPLICATION IS FOR: (Xj New Installation ( ) Alteration ( ) Repair
LOCATION OF PROPOSED FACILITY: County E1=LE. Lot Size tZ�.ac.N Igo.•
City or Town, if within City or Town Limits
LEGAL DESCRIPTION:
STREET (RURAL) ADDRESS:
92
IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY? (X) Yes ( ) No
BUILDING OR SERVICE TYPE: (Check applicable category)
(X) Residential - Single-family dwelling
( ) Residential - Duplex
( ) Commercial - State usage
# Persons 2 0
Residential - Triplex
Residential - Quadplex
# Bedrooms
WASTE TYPES: (Check all applicable)
( ) Commercial or Institutional (X) Dwelling
( ) Non -domestic wastes ( ) Transient Use
( ) Other
SOURCE AND TYPE OF 14ATER SUPPLY: ( K) Well ( ) Spring
Give depth of all wells within 200 feet of the system:
If supplied by community water, give name of supplier:
TYPE OF INDIVIDUAL SEWAGE IDISPOSA.L SYSTEM, PROPOSED:
(Al Septic Tank ( ) Aeration Plant ( )
' .�aUl1, P'r'Ivy 1 i L_!Lr S,L.iIii� iUtisi 7
( ) Pit Privy ( ) Incineration Toilet ( )
( ) Greywater ( ) Other
( ) Garbage Grinder
( x) Dishwasher
( X) Automatic Masher
( ) Creek or Stream
Chemical Toilet
T.__yc_1 Illy, n.t[, CIJ.en IJJ..
Recycling, Other Use
WILL EFFLUENT BE DISCHARGED DIRECTL'r INTO IWATERS OF THE STATE? ( ) Yes ()C) No
Signature
Date
INFORMATION BELOW TO BE FILLED OUT BY ENVIRONMENTAL HEALTH OFFICER
GROUND CONDITIONS: Percent Ground Slope: `'
Depth to Bedrock (per 8' Profile Hole C '7 G(� Depth to Groundwater Table
SOIL PERCOLATION TEST RESULTS: �� h P Minutes per inch in Hole No. 1
Minutes per inch in Hole No. 2
,f l( t1i nutes per inch in Hole No. 3
FINAL DISPOSAL BY: ( ) Absorption Trench, Bed or Pit ( ) Evapotranspiration
( ) Above Ground Dispersal ( ) Sand Filter
( ) Underground Dispersal ( ) 'Wastewater Pond
( ) Other
f
Bu;fLDINGDIVISION INSPECTION REQUEST
P::O. Box 179
PHONE: 328-7311 E A G LE C O U N J Y
D),TE 4--JOB NAME
TIME RECEIVED V AM PM CALLER
BUILDING
FOOTING
FOUNDATION
FRAMING
FINAL
PARTIAL
LOCATION:
COVER
INSULATION
SHEETROCK
VENEER
ROOF
PARTIAL
LOCATION:
PLUMBING
ROUGH
STANDPIPE
FINAL W D C S
PARTIAL
LOCATION:
MECHANICAL
ELECTRICAL
VENTILATION
HEATING
HOODS
TEMPORARY
ROUGH
FINAL
SMOKE DETECTOR
PARTIAL
LOCATION:
PARTIAL
LOCATION:
❑ OTHER ❑ PARTIAL. LOCATION
READY FOR INSPECTION.
r' 1
MON , ' TUE WED THUR FRI AM PM
COMMENTS: G /
GAG �-
❑ APPROVED ❑ DISAPPROVED\ ❑ REINSPECT
❑ UPON THE FOLLOWING CORRECTIONS:
CORRECTIONS
DATE
EAGLE COUNTY ENVIRONMENTAL HEALTH
ROUTE FORM
// - /6- F / NAME 9/i
DATE ROUTED �,� ���� APPLIC. N0.
LOCATION
Please review the attached Individual Sewage Disposal System Permit Application and
return it and this completed form to the Environmental Health Office.
PLANNING: Complies with: YES NO REVIE14ED BY PATE
Subdivision Regulations:
Zoning Regulations:
Recommend Approval:
COMMENTS:
BUILDING:
Building Permit Applied For:
Building Permit Issued:
Recommend Approval:
COMMENTS: 70 /
ENGINEER: Complies with:
Roads:
Grading:
Drainage:
Recommend Approval:
COMMENTS:
ENVIRONMENTAL HEALTH:
Floodplain Permit Necessary:
I.S.D.S. Regs. Compliance:
Recommend Approval:
COMMENTS:
YES NO REVIEWED BY DATE
YES NO REVIEWED BY DATE
YES NO REVIEWED BY DATE
�
i
CONSTRUCTION PERMIT APPLICATION
Jurisdiction of EAGLE COUNTY
USE THIS FORM WHEN APPLYING FOR ANY OR.A-LL--QF THE FOLLOWING PERMITS:
CIRCLE THOSE THAT APPLY— [ A ] Building [ B ]' Plumbing [ C ] Electrical [ D ] Mechanical
[ E ] Road Cut/Right of Way [ F ] Individual Sewage Disposal System [ G ] Grading [ H ] Sign
Applicant to complete numbered spaces only.
JOB ADDRESS
1 LEGAL
DEAL
LOT NO.
BLK
TRACT
1 ❑SFE ATTACHED SHEET 1
OWNER
2`
MAIL ADDRESS
ZIP PHONE
CONTRACTOR
3 ,.
MAILADDRESS
PHONE LICENSE NO.
ARCHITECT OR DESIGNER
4
MAIL ADDRESS
PHONE LICENSE NO.
ENGINEER
5
MAIL ADDRESS
PHONE LICENSE NO.
LENDER
6
MAILADDRESS
BRANCH
USE OF BUILDING
7
No, of
Dwelling Units
8 Class of work: ❑ NEW ❑ ADDITION
O ALTERATION
❑ REPAIR ❑ MOVE ❑ REMOVE
9 Describe work:
10 Change of use from
Change of use to
11 Valuation of work: $
14
Total floor area of structure:
12 Acreage or sq. footage of lot:
15
Height of structure above finish grade:
13 Sq. footage of lot coverage:
16 Special Conditions and Additional Information:
17
Energy Award:
SITE PLAN MUST BE INCLUDED WITH THIS APPLICATION: exceptions are listed in
Eagle County Building Resolution. For site plan preparation instructions refer to Eagle County
publication "Graphic & Submittal Requirements for Site Plans".
18 I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS _ /f
APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.
ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS
TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT DATE
HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT
PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING
CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. SIGNATURE OF OWNER (IF OWNER BUILDER) DATE
APPLICATION ACCEPTED BY
PLANS CHECKED BY
APPROVED FOR ISSUANCE BY
White Copy —INSPECTOR Canary Copy —APPLICANT Pink Copy —ENVIRONMENTAL HEALTH Gold Copy —ASSESSOR
JOB NAM[
0551 Hignett
Creek Ranch
Cattle Creek
Lot 92 Blue
Sub 3148 Upper IIT
JOB NO� �
S�
Ana � ncerrnni
BILL TO
DATE STARTED
DATE COMPLETED
DATE BILLED
JOB COST SUMMARY
TOTAL SELLING PRICE
TOTAL MATERIAL
PERMIT # 551
OWNER: William * gnett
LOCATION: Lot 92 - Blue Creek Ranch Subdivision
INSTALLER: Owner
Design Engineer - Dave Grounds
SIZE OF TANK: 1,000 gallons
DWELLING: Residential - 3 bedrooms x 200 sq.ft.
PERC RATE: one inch/10 minutes (600 sq.ft.)
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
Finalized
-)-' -11 l _.
11-16-81
By: Erik Edeen
_DER
11
Printed in USA
f
Untreated Building Paper or
1'61 1 6 2" of Hoy or Straw
0
TOPSOIL
p
a - — o
--
f f
I/2- 21/2 Washedr
Grovel m
F t
1 �
3" O Perforated P V.C.
ASTM D2729
R
ABSORPTION TRENCH
GENERAL NOTES:
1)
All materials and field ccastruction to meet Eagle
County
regulations on Individual Sewage Disposal Systems.
2)
Location of septic tank arl leachfield are approximate
and may
require field adjustment.
to be 3-inch diameter Sewer and Drain
ASTM D2729.
3}
4)
tali sewer pipe
The septic tank shall be bedded on three inches of minus
1/2-inch
5)
material.
All connections to the septic tank and distribution
boxes shall
be grog ited and leakproof.
6)
5' of cast iron or 3034 PVC shall be used for house
connection
and at inlet and outlet of septic tank.
DESIGN CRITERIA AND CALCULATI)NS:
1)
Percolation rate 10 min./inch
2)
3 bedrooms
3)
Regnirec trench area 600 sq. f t.
4)
Septic tank required - 1000 gallon
SITE PLAN
FOR
SEPTIC SYSTEM
-\\--I\Tonk
w
X
t\
94.9
E X I S T I N G
HOUSE
NOTES:
1) Contour inte 7al - 1 foot
2) Benchmark -(,round at southwest house corner - Elev. 194.9'
3) O designs s a tree
moo_
Q
o A
ENVIRONMENTAL. HE�Lf�
PJ
20 0 20 410
SCALE: I inch = 20 feet
SITE PLAN FOR SEPTIC SYSTEM
ounta'n engineering 6 lond vvrvvytnp co.
406 So. Hyland Sauore Sups A I
Glenwood Springs, Colorado &601
(303)445-2U43
PREPARED FOR
Bill Hignett
DRN. BY DSD CKD. BY DWG SHEET OF
DATE 1 i /I j/R1 I SCALE „= 20' I JOB NO.