HomeMy WebLinkAbout550 Mill St - 219723414009RES-017098-2019
Inspection Result
Eagle County, Colorado
P.O. Box 179 500 Broadway Eagle, CO
Phone: (970) 328-8730 Fax: (970) 328-7185
IVR Phone: 1-866-701-3307
Inspection Number: INSP-517315-2022 Permit Number: OWTS-017151-2019
Inspection Date: 09/07/2022
Inspector:
Permit Type: OWTS Permit
Inspection Type: OWTS Final Inspection
Work Classification: NewOwner:Allen & Danelle Brown
Job Address:0 Seventh ST IVR Pin Number:188675
Eagle, CO 81631 Project:<NONE>
Parcel Number:219723414009
Contractor:Phone: (970) 328-0876 / Cell: (970) 471-2121Brock Civil LLC
Inspection Status: Approved
Inspection Notes
Inspector Comments
Added Item: Septic Tank
A 1000 Valley Precast concrete septic tank was installed with visual and audible alarm system.
Added Item: Record Drawing
Received 9/6/2022 from Brock Civil.
Added Item: Record Photos
Received 9/6/2022 from Brock Civil.
Added Item: Site and Soil
Received 8/5/2019 from Brock Civil.
Added Item: Final Certification Letter
Received 9/6/2022 from Brock Civil.
Added Item: General Plan
Received 8/5/2019 from Brock Civil.
Added Item: Identification of Systems Contractor
Brock Civil was the licensed installer.
Wednesday, September 7, 2022
For more information visit: http://www.eaglecounty.us
Page 1 of 1
Page | 1
PROGRESS PICTURES REPORT, COMPLETE, 2022
OWTS – 017151- 2019
WORK FOR ALLEN BROWN
SEVENTH AND MILL STREET, EAGLE COUNTY, CO 81631
PN 2197-234-14-009
Constructed by Licensed installer BROCK CIVIL, LLC
21-16,
PICTURE 1 2021
CLEAN-OUT AND FLEXIBLE FERNCO FITTING AT HOUSE EXIT, 3 FT.
Page | 2
PICTURE 2 2021
4 INCH SCHEDULE 40 AT 2% MIN. NOTICE SCHEDULE 40 PIPE USED
FOR BEST PROTECTION FOR FROST COMPARED TO SDR 35.
Page | 3
PICTURE 3 2021
SCH 40 PIPE AT 2 % MIN. ¾” SCREEN ROCK BACKFILL.
Page | 4
PICTURE 4 AUDIBLE AND VISUAL ALARM NORTH WEST OF
SEPTIC TANKS ON DECK IN PLAIN SIGHT. OWNER TO REPLACE
BATTERY AS NEEED YEARLY MIN.
NO VEHICULAR TRAVEL OVER TANK OR PIPE.
Page | 5
PICTURE 5 TAR AND GASKET AT TANK ENTRANCE.
Page | 6
PICTURE 6 ENTRANCE INTO 1,000 GAL TANK WITH CLEANOUT.
Page | 7
PICTURE 7 2021
CONCRETE, ONE- PIECE SEPTIC TANK BY VALLEY PRECAST, SET
ON 6 INCHES WASHED ROCK, LEVEL. BACKFILLED TO GRADE.
CONCRETE LIDS PER MFGR. CLEAN AS REQUIRED. MINIMUM.
PUMP TANK ONCE PER 2-3 YEARS OR PER REG #43.
Professional Services
September 15, 2017
Brown Cabin
Lots 11, 12 and 13 Block 26
Fulford, CO
PN 2197-234-00-003
DESIGN CALCULATIONS FOR SEPTIC SYSTEM
REFERENCES
Eagle County Public Health Agency On-Site Wastewater Treatment System Regulations adopted May 13, 2014 (“Regulations”).
Colo. Dept. of Public Health and Environment Regulation #43 5 CCR 1002-43.
DESIGN FLOWS
Number of bedrooms = 2
Number of persons per bedroom = 2 (design flow)
Single Family Residential Design Flows = 75 gallons/day/person
Q design = 2 bdrms x 2 persons/bdrm x 75 gallons/person/day = 300 gpd
Owner to recognize that tank is only for holding and that more frequent pumping may be required.
SEPTIC TANK & PIPE CONSTRUCTION: Install septic tank level with sand gravel bedding. Install the delivery pipe from the
residence to the septic tank 2% slope, Schedule 40 PVC (ASTM D 2665) or SDR 35. Insulate under driveway or any parking area with 2”
rigid insulation. Septic tank to have risers brought to or above final grade and shall have a secure locking mechanism.
ALARM: A visual and audible alarm shall be incorporated into the controls and electrical connections. Alarm to be in an open area or
area easily visible.
NOTES:
1.The building sewer line from the house to the septic tank shall have a slope of ¼ inch per foot (2%). Bends in the building sewer shall
be limited to 45 degrees.
2.Use topsoil for vegetative cover.
3.Avoid vehicle traffic, animal concentrated loads and irrigation over the system. Fencing advised.
4.The Septic System Installation shall be inspected by the Design Engineer prior to backfill.
5.All installations shall meet the rules and regulations of the Eagle County Environmental Health Department.
6.Electrical requirements of alarm to be determined by Electrical Contractor prior to construction. In general, all electrical to be 18”
below grade.
7.Pump septic tank every 2-3 years minimum to prevent deterioration of concrete & overflow
8.Installer must be licensed installer in Eagle County; see permit.
MINIMUM DIMENSIONS TO FACILITIES
ACTUAL (MIN. REQ'D)
SEPTIC TANK TO BUILDING 6 FT (5 FT)
SEPTIC TANK TO WATER LINE 15 FT (10 FT)
BUILDING SEWER TO WATER LINE 15 FT (10 FT)
See 43.7, Table 7-1 for further information and requirements if changes are made to assure proper clearances.
5"
5"
Flexible
Boot
106"
53"56"
4"
Top
View
Section
View
68"
3"
20" Clear Access
TANK
ID
49"
19"
19"
·
·
·
·
·
·
·
·
·
·
·
·
·
1,000 Gal Tank (Holding)
Non-shrink concrete
SEPTIC TANK (OWTS & PERMIT)
N
SEPTIC TANK (OWTS & PERMIT)
N