HomeMy WebLinkAbout1001 Ten Peaks Mesa Rd - 239104102001Inspection Result
Eagle County, Colorado
P.O. Box 179 500 Broadway Eagle, CO
Phone: (970) 328-8730 Fax: (970) 328-7185
IVR Phone: 1-866-701-3307
Inspection Number: INSP-504142-2020 Permit Number: OWTS-017150-2019
Inspection Date: 12/01/2020
Inspector: Lewandowski, Claire
Permit Type: OWTS Permit
Inspection Type: OWTS Final Inspection
Work Classification: NewOwner:Tami Kochen
Job Address:1001 TEN PEAKS MESA RD IVR Pin Number:188674
EL JEBEL AREA, CO Project:<NONE>
Parcel Number:239104102001
Contractor:Phone: (970) 963-3987 / Cell: (970) 987-7284Daly Excavation
Inspection Status: Approved
Inspection Notes
The above-referenced permit has been inspected and finalized.
The Onsite Wastewater Treatment System (OWTS) was designed and installed to serve the five-bedroom residence on the
above property. Additional information about the maintenance of your septic system needs can be accessed through links on
eaglecounty.org provided on the Environmental Health Department’s septic system resource page.
Be aware that changes in the use of your property or alterations of your building may require commensurate changes to, or
relocation of, your septic system. Landscape features, trees with taproots, irrigation systems, and parking areas above the
soil treatment area can cause a premature system failure. It is equally important that you notice and immediately repair
dripping faucets and hissing toilets as this will certainly cause the system to fail. If you have any questions regarding this
information, please contact us at (970) 328-8755 and reference the OWTS septic permit number.
Inspector Comments
Added Item: Septic Tank
Installed in compliance with approved design. A two compartment 1,500 gallon Roth poly tank was
approved to substitute the concrete tank.
Added Item: Record Drawing
Received, approved.
Added Item: Record Photos
Received, approved.
Added Item: Site and Soil
In compliance.
Added Item: Final Certification Letter
Prepared by design consultant Carla Ostberg. Stamped, signed, and dated November 17, 2020 by
Richard H. Petz, PE.
Added Item: General Plan
Tuesday, December 1, 2020
For more information visit: http://www.eaglecounty.us
Page 1 of 2
Installed in conformance with approved plans.
Added Item: Soil Treatment Area (STA)
Installed in compliance with approved design.
Added Item: Identification of Systems Contractor
Installed by Eagle County Licensed Contractor Joseph Bamford Daly Excavation.
Tuesday, December 1, 2020
For more information visit: http://www.eaglecounty.us
Page 2 of 2
November 13, 2020 Project No. C1457
Tami Kochen
tkochen@gmail.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
1001 Ten Peaks Mesa Road
Eagle County, Colorado
Permit Number OWTS-017150-2019
Tami,
ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS)
on August 22, 2019 for the subject property. Joe Bamford installed the system.
The OWTS design is based on 5-bedrooms, although only a 2-bedroom residence is currently developed.
An average daily wastewater flow of 600 GPD was used.
A 4-inch diameter SDR-35 sewer line with a double-sweep clean out and a minimum 2% grade to the
septic tank was installed after our inspection. Additional clean outs were installed at least 100-feet.
The system installation included a 1500-gallon, two-compartment ‘Roth’ poly septic tank with an effluent
filter on the outlet tee. Orenco® risers bring the manhole lids to grade for access.
Effluent gravity flows to a plastic distribution box, which was accessible from grade with risers. Speed
levelers were installed to assure equal flow to each trench. The STA consists of four trenches, each with
15 ‘Quick 4’ Infiltrator® chambers for a total of 60 chambers and 720 square feet of infiltrative area.
Trenches were separated by 8-feet of undisturbed soil. Inspection ports were installed at the beginning
and end of each trench. Ports may be cut to grade and placed in sprinkler boxes for access. The
infiltrative area was at least 2-feet below grade and did not exceed 3-feet below grade. The infiltrative
area was placed below the topsoil horizon.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are
made to the OWTS in the future. Any additional OWTS construction must be according to the county
regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By:
Carla Ostberg, MPH, REHS Richard H. Petz,
Septic tank installed Effluent filter and risers were installed after inspection
11/17/2020
Distribution box with access from grade angled pipe on inlet pipe installed after inspection
trenches
Trenches, separated by 8-feet
Inspection ports at beginning and end of each trench
832‐R‐13‐002
July 12, 2019 Project No. C1457
Tami Kochen
tkochen@gmail.com
Subsurface Investigation and Onsite Wastewater Treatment System Design
2-Bedroom Residence (+ 3 future bedrooms)
1001 Ten Peaks Mesa
Eagle County, Colorado
Tami,
ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater
treatment system (OWTS) design for the subject residence. The 37.93-acre property is located outside of
Basalt, in an area where OW TSs are necessary.
Legal Description: Subdivision: TEN PEAKS MESA Lot: 1
R649781 MAP 03-17-98
R649782 DEC 03-17-98
R685319 WD 07-15-98
R820047 DEC 01-13-03
Parcel ID: 2391-041-02-001
SITE CONDITIONS
The property is currently undeveloped. A 2-bedroom residence is proposed. Future expansion of the
house is possible. We have sized the OWTS to accommodate a 5-bedroom residence.
The residence will be served potable water from the community water system. The water line runs up the
driveway, to the west of the proposed residence.
The proposed STA is on a hillside near the bee hive, to the southeast of the residence. The STA slopes
to the east at approximately 10%, which is somewhat inconsistent with how the survey has depicted the
topography. The proposed area is covered with native grasses and sage.
Table 1 describes the minimum required setback of OWTS components to physical features on the
property compared to approximate, proposed setback distances.
Table 1
OWTS Components and
Physical Features
Minimum Required Setback Approximate Proposed Setback
House to Septic Tank 5’ 20’
Septic Tank to Well 50’ n/a
Septic Tank to Water Course 50’ n/a
STA to House 20’ 230’
STA to Well 100’ n/a
STA to Water Course 50’ n/a
Page 2
SUBSURFACE
The subsurface was investigated on July 10, 2019 by digging two soil profile test pit excavations (Test Pits).
Visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.1
The materials encountered in the Test Pit #1 consisted of dark brown, clay loam topsoil to 2.0-feet
underlain by tan calcareous sandy silt, or sandy clay with low Plasticity Index to a maximum depth
explored of 7.0-feet. The soils have a blocky to loose structure shape, a moderate structure grade, and
friable to firm consistence. No bedrock or groundwater was encountered.
The materials encountered in Test Pit #2 were consistent with materials in Test Pit #1. The Test Pit was
excavated to a maximum depth of 7.0-feet. No bedrock or groundwater was encountered.
STA sizing is based on Soil Type 2. A long term acceptance rate (LTAR) of 0.6 gallons per square
foot, will be used to design the OWTS.
Test Pit #1
Backfill from soil Test Pit #1
1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
Page 3
Test Pit #1 sieved sample
Note horizons
Page 4
Note moderate structure grade
Test Pit #2 and backfill
Note slope to east is gradual toward fence line
Page 5
View of test pit #1 looking toward Bee Hive
DESIGN SPECIFICATIONS
Design Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 150 GPD (4th and 5th bedrooms) = 600
GPD
LTAR = 0.6 GPD/SF
600 GPD / 0.6 GPD/SF x 1.0 (gravity trenches) x 0.7 (chambers) = 700 SF
The OWTS design is based on 5-bedrooms, although only a 2-bedroom residence is currently proposed.
An average daily wastewater flow of 600 GPD will be used.
For the purposes of this OWTS design, Benchmark Elevation at grade 7673’ has been established as
100’. ALL SERVICE septic, LLC should be notified of any discrepancies or problems with grade
elevations of proposed components during installation of the OWTS.
OWTS Component Minimum Elevation
Primary Tank Inlet Invert 98’ (7671’)
Distribution Box 92.5’ (7665.5’)
Infiltrative Surface 92’ (7665’)
A 4-inch diameter SDR-35 sewer line exiting the residence must have a double-sweep clean out and a
minimum 2% grade to the septic tank. Additional clean outs should be installed at least 100-feet.
The system installation must include a 1500-gallon, two-compartment septic tank with an effluent filter on
the outlet tee. Either an Infiltrator® poly septic tank or Valley Precast concrete septic tank may be used.
We have provided specifications for both septic tanks. Risers must bring the manhole lids to grade for
access. If more than one riser is added to the septic tank, an extension handle must be installed on the
effluent filter.
Effluent will gravity flow to a distribution box, which must be accessible from grade. Flow equalizers or
similar product must be installed to assure equal flow to each trench. The STA will consist of four
trenches, each with 15 ‘Quick 4’ Standard Plus Infiltrator® chambers for a total of 60 chambers and 720
square feet of infiltrative area. Trenches must be separated by at least 4-feet (we recommend 6-feet) of
undisturbed soil. Inspection ports must be installed at the beginning and end of each trench. Ports may
be cut to grade and placed in sprinkler boxes for access. The infiltrative area must be at least 2-feet
Page 6
below grade and must not exceed 3-feet below grade. The infiltrative area must be placed below the
topsoil horizon. Fill over chambers must be 3-inch minus and be able to support vegetative growth.
The component manufacturers are typical of applications used by contractors and engineers in this area.
Alternatives may be considered or recommended by contacting our office. Construction must be
according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided
by Eagle County Environmental Health Department, and this design.
INSTALLATION CONTRACTOR
ALL SERVICE septic, LLC expects that the installer be experienced and qualified to perform the scope of
work outlined in this design. The installer must review this design thoroughly and coordinate with our office
in advance of installation. Any additional conditions in this design or county permit must be completed and
documented prior to final approval of the OWTS installation. Communication between the installer and this
office is expected throughout the installation.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be
performed before backfill, after placement of OWTS components. Septic tanks, distribution devices,
pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic,
LLC should be notified 48 hours in advance to observe the installation.
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over
the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Livestock should not graze on the STA. Plumbing fixtures should be
checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or
leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
Page 7
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high
water conditions and shall be connected to a control breaker separate from the high water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be
according to the county regulations. Requirements not specified in this report must follow applicable
county regulations. The contractor should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working. Licensing of Systems Contractors
may be required by county regulation.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By:
Carla Ostberg, MPH, REHS
7/23/19
• Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
• Installs in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
• Easy to clean by
simply hosing off
whenever the tank
needs pumping
• Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
• Corrosion-proof
construction, to
ensure long life
• Lifetime warranty
Residential Biotube® Effluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a lifetime warranty. They prevent large solids from leaving
the tank, dramatically improving wastewater quality and extending the life
of residential drainfields.
Standard Features & Benefits
• Alarm available, to
signal the need for
cleaning
• Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
• Custom and
commercial sizes
available
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes’ entire
surface for filtering.
Particles larger than
the Biotube’s mesh
are prevented from
leaving the tank.
Optional
Features &
Benefits
Biotube
Filtering
Process
8-in. (200-mm)
Base Inlet Filter
4-in. (100-mm)
Insert Filter
4-in. (100-mm) Biotube Jr.
(4-in. Biotube cartridge avail-
able separately as Insert Filter)
Orenco’s superior effluent filters resist clogging better than all other brands. Our stan-
dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term
protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at
half the size of our standard model, has more filtering capacity than the full-sized filters
sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter
is ideal. And for low-profile tanks, there’s the Base Inlet Filter.
* Covered by patent numbers 5,492,635 and 4,439,323
4-in. (100-mm) Biotube Effluent Filter
APS-FT-1
Rev. 3.4 © 11/10
Orenco Systems®, Inc.
To Order
Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on
“Distributor Locator.”
Nomenclatures
Riser
wall
Tank wall
Filter housing
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube® filter cartridge
Solid base
4-in. Biotube
Effluent Filter
4-in. Biotube Jr.
4-in. Biotube Filter (standard)
4-in. Biotube Jr. (includes cartridge and housing)
Distributed By:
8-in. Biotube Filter (base inlet model)
4-in. Biotube Filter Insert (cartridge only)
Junior series
FT J0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Blank = 1/8" filtration
P = 1/16" filtration
Insert
FT i0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
-
For customized options (e.g., NC
indicates North Carolina regions)
-
Blank = 1/8" filtration
P = 1/16" filtration
FT 04
Biotube effluent filter series
Filter diameter (inches)
Housing height: 36" and 44" are standard
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Cartridge height: 28" and 36" are standard
-
Blank = 1/8" filtration
P = 1/16" filtration
W = fits Type 3034 outlet pipe
S = fits Schedule 40 outlet pipe
FT 2208 14 B
Biotube effluent filter series
Housing height: 22" standard
Cartridge height: 14" standard
Options:
A = float bracket
FS = 2" outlet orifice
FSO = 2" outlet orifice and overflow plate*
Base inlet model
-
Blank = 1/8" filtration
P = 1/16" filtration
Filter diameter (inches)
08 = 8"
* Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT
The Quick4® Plus Standard Chamber
The Quick4 Plus Standard Chamber
offers maximum strength through
its two center structural columns.
This chamber can be installed in
a 36-inch-wide trench. Like the
original line of Quick4 chambers,
it offers advanced contouring
capability with its Contour Swivel
Connection™ which permits turns
up to 15-degrees, right or left. It is
also available in four-foot lengths to
provide optimal installation flexibility.
The Quick4 Plus All-in-One 12
Endcap, and the Quick4 Periscope
are available with this chamber,
providing increased flexibility in
system configurations.
Maximum Strength
APPROVED in _____________________________________________
Quick4 Plus™ Series
Quick4 Plus All-in-One 12 Endcap Benefits:
• May be used at the end of chamber
row for an inlet/outlet or can be
installed mid-trench
• Mid-trench connection feature allows
construction of chamber rows with
center feed, as an alternative to
inletting at the ends of chamber rows
• Center-feed connection allows for
easy installation of serial distribution
systems
• Pipe connection options include
sides, ends or top
Quick4 Plus All-in-One Periscope Benefits:
• Allows for raised invert installations
• 180° directional inletting
• 12” raised invert is ideal for serial
applications
Certified by the International
Association of Plumbing
and Mechanical
Officials (IAPMO)
Quick4 Plus Standard Chamber Specifications
Size
34”W x 53”L x 12”H
(864 mm x 1346 mm x 305 mm)
Effective Length
48” (1219 mm)
Louver Height
8” (203 mm)
Storage Capacity
47 gal (178 L)
Invert Height
0.6” (15 mm), 5.3” (135 mm),
8.0” (203 mm), 12.7” (323 mm)
Quick4 Plus Standard Chamber Benefits:
• Two center structural columns offer increased stability and superior strength
• Advanced contouring connections
• Latching mechanism allows for quick installation
• Four-foot chamber lengths are easy to handle and install
• Supports wheel loads of 16,000 lbs/axle with 12” of cover
Contact Infiltrator Water Technologies’ Technical Services Department for assistance at 1-800-221-4436
4 Business Park Road
P.O. Box 768
Old Saybrook, CT 06475
860-577-7000 • Fax 860-577-7001
1-800-221-4436
www.infiltratorwater.com
U.S. Patents: 4,759,661; 5,017,041; 5,156,488; 5,336,017; 5,401,116; 5,401,459; 5,511,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending.
Infiltrator, Equalizer, Quick4, and SideWinder are registered trademarks of Infiltrator Water Technologies. Infiltrator is a registered trademark in France. Infiltrator Water Technologies is a registered trademark in Mexico.
Contour, MicroLeaching, PolyTuff, ChamberSpacer, MultiPort, PosiLock, QuickCut, QuickPlay, SnapLock and StraightLock are trademarks of Infiltrator Water Technologies.
PolyLok is a trademark of PolyLok, Inc. TUF-TITE is a registered trademark of TUF-TITE, INC. Ultra-Rib is a trademark of IPEX Inc.
© 2013 Infiltrator Water Technologies, LLC. All rights reserved. Printed in U.S.A.PLUS05 0713
Quick4 Plus™ Series
INFILTRATOR WATER TECHNOLOGIES STANDARD LIMITED WARRANTY
(a) The structural integrity of each chamber, endcap and other accessory manufactured by
Infiltrator (“Units”), when installed and operated in a leachfield of an onsite septic system in
accordance with Infiltrator’s instructions, is warranted to the original purchaser (“Holder”) against
defective materials and workmanship for one year from the date that the septic permit is issued for
the septic system containing the Units; provided, however, that if a septic permit is not required by
applicable law, the warranty period will begin upon the date that installation of the septic system
commences. To exercise its warranty rights, Holder must notify Infiltrator in writing at its Corporate
Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. Infiltrator
will supply replacement Units for Units determined by Infiltrator to be covered by this Limited
Warranty. Infiltrator’s liability specifically excludes the cost of removal and/or installation
of the Units.
(b) THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE.
THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
(c) This Limited Warranty shall be void if any part of the chamber system is manufactured by
anyone other than Infiltrator. The Limited Warranty does not extend to incidental, consequential,
special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages,
including loss of production and profits, labor and materials, overhead costs, or other losses or
expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty
coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse,
abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which
are not permitted by the installation instructions; failure to maintain the minimum ground covers
set forth in the installation instructions; the placement of improper materials into the system
containing the Units; failure of the Units or the septic system due to improper siting or improper
sizing, excessive water usage, improper grease disposal, or improper operation; or any other
event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails to comply
with all of the terms set forth in this Limited Warranty. Further, in no event shall Infiltrator be
responsible for any loss or damage to the Holder, the Units, or any third party resulting from
installation or shipment, or from any product liability claims of Holder or any third party. For this
Limited Warranty to apply, the Units must be installed in accordance with all site conditions
required by state and local codes; all other applicable laws; and Infiltrator’s installation instructions.
(d) No representative of Infiltrator has the authority to change or extend this Limited Warranty.
No warranty applies to any party other than the original Holder.
The above represents the Standard Limited Warranty offered by Infiltrator. A limited number of
states and counties have different warranty requirements. Any purchaser of Units should contact
Infiltrator’s Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase, to
obtain a copy of the applicable warranty, and should carefully read that warranty prior to the
purchase of Units.
Quick4 Plus Standard Chamber ___________________________________________________________________________________
Quick4 Plus All-in-One 12 Endcap ________________________________________________________________________________
Quick4 Plus All-in-One Periscope ________________________
EFFECTIVE LENGTH48"
12"
34"
QUICK4 PLUS
ALL-IN-ONE PERISCOPE
(360° SWIVEL)
12.7" INVERT
PRESSURIZED PIPE DRILL
POINTS LOCATIONS
(2 PLACES)
33"
18"
8" INVERT
13"
EFFECTIVE LENGTH48"
12"
34"
QUICK4 PLUS
ALL-IN-ONE PERISCOPE
(360° SWIVEL)
12.7" INVERT
PRESSURIZED PIPE DRILL
POINTS LOCATIONS
(2 PLACES)
33"
18"
8" INVERT
13" FRONT VIEW SIDE VIEW
EFFECTIVE LENGTH48"
12"
34"
QUICK4 PLUS
ALL-IN-ONE PERISCOPE
(360° SWIVEL)
12.7" INVERT
PRESSURIZED PIPE DRILL
POINTS LOCATIONS
(2 PLACES)
33"
18"
8" INVERT
13"
6"
5"9"