Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout250 Forest Dr - 218923301002Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-019833-2020
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 10/16/2020 Expires: 2/15/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
250 FOREST DR, 218923301002
Owner Information Address
Arthur Reeds Phone:
Cell: (970) 379-5744
Email:
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Excavation Services Inc troy@excavationservices.b
iz
(970) 948-1915OWTSPL-000093-20
20
Permitted Construction / Details:
Install the OWTS exactly as depicted in the CBO Inc design dated September 6, 2020, prepared by Carla Ostberg,
stamped signed and dated September 24, 2020 by Romeo A. Baylosis, PE. The system is designed to serve a
two-bedroom single family residence.
The OWTS consists of a 1,000 gallon Infiltrator two-compartment poly septic tank with an effluent filter in the outlet
tee, followed by a 420 square foot soil treatment area via three rows of 12 Infiltrator Quick4 Standard Plus chambers,
for a total of 36 chambers, in a screen rock bed, no less than two feet and no more than four feet below grade. Install
inspection ports in all four corners of the bed.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system or occupancy of the dwelling.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Claire Lewandowski
Date
October 16, 2020
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Friday, October 16, 2020 1
Inspection Result
Eagle County, Colorado
P.O. Box 179 500 Broadway Eagle, CO
Phone: (970) 328-8730 Fax: (970) 328-7185
IVR Phone: 1-866-701-3307
Inspection Number: INSP-506912-2021 Permit Number: OWTS-019833-2020
Inspection Date: 04/30/2021
Inspector: Sell, Danielle
Permit Type: OWTS Permit
Inspection Type: OWTS Final Inspection
Work Classification: NewOwner:Arthur Reeds
Job Address:250 FOREST DR IVR Pin Number:191442
CO Project:<NONE>
Parcel Number:218923301002
Contractor:Phone: (970) 963-8355 / Cell: (970) 948-1915Excavation Services Inc
Inspection Status: Approved
Inspection Notes
This letter is to inform you that the above-referenced permit has been inspected and finalized. The Onsite Wastewater
Treatment System (OWTS) was designed and installed to serve the two-bedroom residence on the above property. The
OWTS installed is considered a higher level treatment system by Eagle County Public Health Agency’s OWTS Regulations
and must be operated and maintained in accordance with applicable regulations.
Inspector Comments
Added Item: Septic Tank
1000 gallon poly Infiltrator septic tank, two-compartment.
Added Item: Record Drawing
Received 4/30/2021 from CBO Inc.
Added Item: Record Photos
Received 4/30/2021 from CBO Inc.
Added Item: Site and Soil
Received 10/16/2021 from CBO Inc.
Added Item: Final Certification Letter
Received 4/30/2021 from CBO Inc.
Added Item: General Plan
Received 10/16/2021 from CBO Inc.
Added Item: Soil Treatment Area (STA)
432 square feet, gravity flow through 3 rows of 12 chambers.
Added Item: Identification of Systems Contractor
Excavation Services Inc.
Friday, April 30, 2021
For more information visit: http://www.eaglecounty.us
Page 1 of 2
Friday, April 30, 2021
For more information visit: http://www.eaglecounty.us
Page 2 of 2
33 Four Wheel Drive Road
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
March 29, 2021 Project No. C1536
Jon Nell Reeds
jonnell@carbondaleco.net
Onsite Wastewater Treatment System (OWTS) Installation Observations
250 Forest Drive
Eagle County, Colorado
Permit Number OWTS-19833-2020
Jon Nell,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on October 16,
2020 for the subject property. Excavation Services installed the system.
The OWTS design is based on 2-bedrooms. An average daily wastewater flow of 300 GPD was
used.
A distance of 107-feet from the well to the septic tank was verified.
A new 4-inch Schedule 40-sewer line was installed with a double-sweep clean out and minimum 2% fall
to the septic tank.
The system installation included a 1000-gallon, two-compartment poly Infiltrator® septic tank with an
effluent filter on the outlet tee. This filter must be cleaned annually, or as needed. Risers bring the
manhole lids to grade for access.
Effluent gravity flows to a level manifold connecting three rows of ‘Quick 4’ Infiltrator® chambers, with 12
chambers in each row for a total of 36 chambers and 432 square feet of infiltrative area in the soil
treatment area (STA). Inspection ports were installed at each corner of the bed. Ports may be cut to
grade and placed in sprinkler boxes for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
4-27-2021
Please call with questions.
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS Romeo Baylosis, P.E.
View of septic tank and STA
Chamber bed Manifold bedded
Inlet pipe Risers on septic tank
Building manifold
Sewer line from tank to STA
Level manifold
Effluent filter
Inspection ports to be installed
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-019833-2020
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 10/16/2020 Expires: 2/15/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
250 FOREST DR, 218923301002
Owner Information Address
Arthur Reeds Phone:
Cell: (970) 379-5744
Email:
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Excavation Services Inc troy@excavationservices.b
iz
(970) 948-1915OWTSPL-000093-20
20
Permitted Construction / Details:
Install the OWTS exactly as depicted in the CBO Inc design dated September 6, 2020, prepared by Carla Ostberg,
stamped signed and dated September 24, 2020 by Romeo A. Baylosis, PE. The system is designed to serve a
two-bedroom single family residence.
The OWTS consists of a 1,000 gallon Infiltrator two-compartment poly septic tank with an effluent filter in the outlet
tee, followed by a 420 square foot soil treatment area via three rows of 12 Infiltrator Quick4 Standard Plus chambers,
for a total of 36 chambers, in a screen rock bed, no less than two feet and no more than four feet below grade. Install
inspection ports in all four corners of the bed.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system or occupancy of the dwelling.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Claire Lewandowski
Date
October 16, 2020
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Friday, October 16, 2020 1
832‐R‐13‐002
33 Four Wheel Drive Road
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
September 6, 2020 Project No. C1536
Jon Nell Reeds
jonnell@carbondaleco.net
Subsurface Investigation and Onsite Wastewater Treatment System Design
2-Bedroom Residence
250 Forest Drive
Eagle County, Colorado
Jon Nell,
CBO Inc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The property is located outside of Carbondale, in an area
where OWTSs and wells are necessary.
Legal Description: Subdivision: COULTER CREEK RANCHES Lot: 7
Parcel ID: 2189-233-01-002
SITE CONDITIONS Initial construction of a structure has begun, and it intended to become a 2-bedroom residence.
A well was drilled to the southwest of the residence. The well is greater than 50-feet from the proposed
septic tank and greater than 100-feet from the proposed soil treatment area (STA).
The proposed STA is located to the north of the residence and west of the driveway. The area is in a
clearing and is covered with native grasses where surrounding areas are vegetated with aspen trees.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
prior to construction of the STA.
SUBSURFACE The subsurface was investigated on July 12, 2020 by digging two soil profile test pit excavations (Test Pits).
Visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.1
The materials encountered in the Test Pit #1 consisted of medium brown sandy loam to loam with
increasing angular rock with depth to a maximum depth explored of 7.0-feet. No bedrock or groundwater
was encountered.
The materials encountered in Test Pit #2 were consistent with those encountered in Test Pit #1. Test Pit
#2 was excavated to a maximum depth explored of 7.0-feet. No bedrock or groundwater was
encountered.
1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
Page 2
A sample of the soils was taken from Test Pit #1 at 3-feet below grade. Soil structure grade was
moderate. The soil formed a ball and a ribbon approximately 1-inch in length before breaking. Soil
structure shape was blocky and consistence was friable. Soil texture was more gritty than smooth.
STA sizing is based on Soil Type 2, Sandy Loam to Loam. A long term acceptance rate (LTAR) of 0.6
gallons per square foot.
View of area of Test Pits
Sidewall Test Pit #1
Page 3
Sieved sample ribbon just under 1-inch
DESIGN SPECIFICATIONS Design Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 2 Bedrooms = 300 GPD
LTAR = 0.6 GPD/SF
300 GPD / 0.6 gal/SF x 1.2 (gravity bed) x 0.7 (chambers) = 420 SF
The OWTS design is based on 2-bedrooms. An average daily wastewater flow of 300 GPD will be used.
For the purposes of this OWTS design, Benchmark Elevation has been established as the sewer line
existing the residence as 100’. CBO Inc. should be notified of any discrepancies or problems with grade
elevations of proposed components during installation of the OWTS.
OWTS Component Minimum Elevation
Primary Tank Inlet Invert Approx. horizontal distance 43’ / min. 2% fall to
septic tank / min. 10.75” fall
Infiltrative Surface Approx. horizontal distance 22’ / min. 1% fall to
STA / min. 2.75” fall
A new 4-inch Schedule 40-sewer line must be installed with a double-sweep clean out and minimum 2%
fall to the septic tank. We recommend minimum Schedule-40 under the driveway.
The system installation must include a 1000-gallon, two-compartment poly Infiltrator® septic tank with an
effluent filter on the outlet tee. Risers must bring the manhole lids to grade for access. If more than one
riser is added to the septic tank, an extension handle must be installed on the effluent filter.
Effluent will gravity flow to a level manifold connecting three rows of ‘Quick 4’ Infiltrator® chambers, with
12 chambers in each row for a total of 36 chambers and 432 square feet of infiltrative area. Inspection
ports must be installed at each corner of the bed. Ports may be cut to grade and placed in sprinkler
boxes for access.
Page 4
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
COMPONENT MANUFACTURER MODEL NO. COMMENTS
Septic Tank Infiltrator® IM 1060-2CP 2-compartment, 1000-
gallon poly septic tank
Effluent Filter Orenco® 4-inch diameter, full size
Chambers Infiltrator® (36) ‘Quick 4’ Standard Plus Chambers
The component manufacturers are typical of applications used by contractors and engineers in this area.
Alternatives may be considered or recommended by contacting our office. Construction must be
according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided
by Eagle County Environmental Health Department, and this design.
INSTALLATION CONTRACTOR
CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours
in advance to observe the installation.
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
Page 5
9-24-2020
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, CBO Inc. should be notified. All OWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Please call with questions.
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS Romeo A. Baylosis, P.E.
9/6/2020 Eagle County GIS Viewer
https://map.eaglecounty.us/GIS_Viewer/?query=Address Labels,PARCEL_NUM,218923301002 1/1
0 150 300ft
+
–
Address, Parcel, or Schedule
39.518 -107.079 Degrees
Eagle County GIS Viewer http://www.eaglecounty.us
250 Forest Drive Legend
90 ft
N➤➤N
• Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
• Installs in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
• Easy to clean by
simply hosing off
whenever the tank
needs pumping
• Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
• Corrosion-proof
construction, to
ensure long life
• Lifetime warranty
Residential Biotube® Effluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a lifetime warranty. They prevent large solids from leaving
the tank, dramatically improving wastewater quality and extending the life
of residential drainfields.
Standard Features & Benefits
• Alarm available, to
signal the need for
cleaning
• Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
• Custom and
commercial sizes
available
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes’ entire
surface for filtering.
Particles larger than
the Biotube’s mesh
are prevented from
leaving the tank.
Optional
Features &
Benefits
Biotube
Filtering
Process
8-in. (200-mm)
Base Inlet Filter
4-in. (100-mm)
Insert Filter
4-in. (100-mm) Biotube Jr.
(4-in. Biotube cartridge avail-
able separately as Insert Filter)
Orenco’s superior effluent filters resist clogging better than all other brands. Our stan-
dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term
protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at
half the size of our standard model, has more filtering capacity than the full-sized filters
sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter
is ideal. And for low-profile tanks, there’s the Base Inlet Filter.
* Covered by patent numbers 5,492,635 and 4,439,323
4-in. (100-mm) Biotube Effluent Filter
APS-FT-1
Rev. 3.4 © 11/10
Orenco Systems®, Inc.
To Order
Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on
“Distributor Locator.”
Nomenclatures
Riser
wall
Tank wall
Filter housing
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube® filter cartridge
Solid base
4-in. Biotube
Effluent Filter
4-in. Biotube Jr.
4-in. Biotube Filter (standard)
4-in. Biotube Jr. (includes cartridge and housing)
Distributed By:
8-in. Biotube Filter (base inlet model)
4-in. Biotube Filter Insert (cartridge only)
Junior series
FT J0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Blank = 1/8" filtration
P = 1/16" filtration
Insert
FT i0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
-
For customized options (e.g., NC
indicates North Carolina regions)
-
Blank = 1/8" filtration
P = 1/16" filtration
FT 04
Biotube effluent filter series
Filter diameter (inches)
Housing height: 36" and 44" are standard
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Cartridge height: 28" and 36" are standard
-
Blank = 1/8" filtration
P = 1/16" filtration
W = fits Type 3034 outlet pipe
S = fits Schedule 40 outlet pipe
FT 2208 14 B
Biotube effluent filter series
Housing height: 22" standard
Cartridge height: 14" standard
Options:
A = float bracket
FS = 2" outlet orifice
FSO = 2" outlet orifice and overflow plate*
Base inlet model
-
Blank = 1/8" filtration
P = 1/16" filtration
Filter diameter (inches)
08 = 8"
* Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT
The Quick4® Plus Standard Chamber
The Quick4 Plus Standard Chamber
offers maximum strength through
its two center structural columns.
This chamber can be installed in
a 36-inch-wide trench. Like the
original line of Quick4 chambers,
it offers advanced contouring
capability with its Contour Swivel
Connection™ which permits turns
up to 15-degrees, right or left. It is
also available in four-foot lengths to
provide optimal installation flexibility.
The Quick4 Plus All-in-One 12
Endcap, and the Quick4 Periscope
are available with this chamber,
providing increased flexibility in
system configurations.
Maximum Strength
APPROVED in _____________________________________________
Quick4 Plus™ Series
Quick4 Plus All-in-One 12 Endcap Benefits:
• May be used at the end of chamber
row for an inlet/outlet or can be
installed mid-trench
• Mid-trench connection feature allows
construction of chamber rows with
center feed, as an alternative to
inletting at the ends of chamber rows
• Center-feed connection allows for
easy installation of serial distribution
systems
• Pipe connection options include
sides, ends or top
Quick4 Plus All-in-One Periscope Benefits:
• Allows for raised invert installations
• 180° directional inletting
• 12” raised invert is ideal for serial
applications
Certified by the International
Association of Plumbing
and Mechanical
Officials (IAPMO)
Quick4 Plus Standard Chamber Specifications
Size
34”W x 53”L x 12”H
(864 mm x 1346 mm x 305 mm)
Effective Length
48” (1219 mm)
Louver Height
8” (203 mm)
Storage Capacity
47 gal (178 L)
Invert Height
0.6” (15 mm), 5.3” (135 mm),
8.0” (203 mm), 12.7” (323 mm)
Quick4 Plus Standard Chamber Benefits:
• Two center structural columns offer increased stability and superior strength
• Advanced contouring connections
• Latching mechanism allows for quick installation
• Four-foot chamber lengths are easy to handle and install
• Supports wheel loads of 16,000 lbs/axle with 12” of cover
Contact Infiltrator Water Technologies’ Technical Services Department for assistance at 1-800-221-4436
4 Business Park Road
P.O. Box 768
Old Saybrook, CT 06475
860-577-7000 • Fax 860-577-7001
1-800-221-4436
www.infiltratorwater.com
U.S. Patents: 4,759,661; 5,017,041; 5,156,488; 5,336,017; 5,401,116; 5,401,459; 5,511,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending.
Infiltrator, Equalizer, Quick4, and SideWinder are registered trademarks of Infiltrator Water Technologies. Infiltrator is a registered trademark in France. Infiltrator Water Technologies is a registered trademark in Mexico.
Contour, MicroLeaching, PolyTuff, ChamberSpacer, MultiPort, PosiLock, QuickCut, QuickPlay, SnapLock and StraightLock are trademarks of Infiltrator Water Technologies.
PolyLok is a trademark of PolyLok, Inc. TUF-TITE is a registered trademark of TUF-TITE, INC. Ultra-Rib is a trademark of IPEX Inc.
© 2013 Infiltrator Water Technologies, LLC. All rights reserved. Printed in U.S.A.PLUS05 0713
Quick4 Plus™ Series
INFILTRATOR WATER TECHNOLOGIES STANDARD LIMITED WARRANTY
(a) The structural integrity of each chamber, endcap and other accessory manufactured by
Infiltrator (“Units”), when installed and operated in a leachfield of an onsite septic system in
accordance with Infiltrator’s instructions, is warranted to the original purchaser (“Holder”) against
defective materials and workmanship for one year from the date that the septic permit is issued for
the septic system containing the Units; provided, however, that if a septic permit is not required by
applicable law, the warranty period will begin upon the date that installation of the septic system
commences. To exercise its warranty rights, Holder must notify Infiltrator in writing at its Corporate
Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. Infiltrator
will supply replacement Units for Units determined by Infiltrator to be covered by this Limited
Warranty. Infiltrator’s liability specifically excludes the cost of removal and/or installation
of the Units.
(b) THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE.
THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
(c) This Limited Warranty shall be void if any part of the chamber system is manufactured by
anyone other than Infiltrator. The Limited Warranty does not extend to incidental, consequential,
special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages,
including loss of production and profits, labor and materials, overhead costs, or other losses or
expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty
coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse,
abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which
are not permitted by the installation instructions; failure to maintain the minimum ground covers
set forth in the installation instructions; the placement of improper materials into the system
containing the Units; failure of the Units or the septic system due to improper siting or improper
sizing, excessive water usage, improper grease disposal, or improper operation; or any other
event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails to comply
with all of the terms set forth in this Limited Warranty. Further, in no event shall Infiltrator be
responsible for any loss or damage to the Holder, the Units, or any third party resulting from
installation or shipment, or from any product liability claims of Holder or any third party. For this
Limited Warranty to apply, the Units must be installed in accordance with all site conditions
required by state and local codes; all other applicable laws; and Infiltrator’s installation instructions.
(d) No representative of Infiltrator has the authority to change or extend this Limited Warranty.
No warranty applies to any party other than the original Holder.
The above represents the Standard Limited Warranty offered by Infiltrator. A limited number of
states and counties have different warranty requirements. Any purchaser of Units should contact
Infiltrator’s Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase, to
obtain a copy of the applicable warranty, and should carefully read that warranty prior to the
purchase of Units.
Quick4 Plus Standard Chamber ___________________________________________________________________________________
Quick4 Plus All-in-One 12 Endcap ________________________________________________________________________________
Quick4 Plus All-in-One Periscope ________________________
EFFECTIVE LENGTH48"
12"
34"
QUICK4 PLUS
ALL-IN-ONE PERISCOPE
(360° SWIVEL)
12.7" INVERT
PRESSURIZED PIPE DRILL
POINTS LOCATIONS
(2 PLACES)
33"
18"
8" INVERT
13"
EFFECTIVE LENGTH48"
12"
34"
QUICK4 PLUS
ALL-IN-ONE PERISCOPE
(360° SWIVEL)
12.7" INVERT
PRESSURIZED PIPE DRILL
POINTS LOCATIONS
(2 PLACES)
33"
18"
8" INVERT
13" FRONT VIEW SIDE VIEW
EFFECTIVE LENGTH48"
12"
34"
QUICK4 PLUS
ALL-IN-ONE PERISCOPE
(360° SWIVEL)
12.7" INVERT
PRESSURIZED PIPE DRILL
POINTS LOCATIONS
(2 PLACES)
33"
18"
8" INVERT
13"
6"
5"9"