Permit
Permit No. OWTS-019702-2020
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 9/25/2020 Expires: 1/25/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
440 FROST CREEK DR, EAGLE AREA,210925302007
Owner Information Address
Ken and Mamie Jones 1908 Grosvenor LN
Colleyville, TX
Phone: (970) 331-1150
Cell:
Email: kjones@epacsales.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
JVA Inc, Simon Farrell (303) 444-1951 sfarrell@jvajva.com
Contractor License Number Phone Email
Defina Construction, INC gary@definaconstruction.c
om
(970) 376-6702OWTSPL-000081-20
20
Permitted Construction / Details:
Install the OWTS exactly as depicted in the JVA, Inc design stamped, signed, and dated September 11, 2020 by
Simon A. Farrell, PE. The system is designed to serve a 5 bedroom single family residence.
The system consists of a Valley Precast 1,250 gallon, single compartment tank with effluent screen and alarm placed
on the outlet, followed by a 2,000 gallon Valley Precast 3-compartment recirculating/dose tank which will send
wastewater to two, Advantex AX-20 pods for nitrification using an Orenco PF500512 pump. Nitrified effluent flows to
the splitter valve (mode 3B) for recirculation to the 1,250 gallon first tank for denitrification then is dosed using an
Orenco PF500512 pump to 576 square feet of soil treatment area (STA). The STA consists of two beds, each
arranged with of three rows of 8 Infiltrator Quick 4 Plus Standard chambers for a total of 48 chambers. Distribution
lateral details, along with orifice size, spacing and orientation are on the design drawing.
The contractor must verify that all electrical components and inspections are covered under the electrical permit
associated with the Orenco Vericom control panel (Model VCOM-AX20B2) and pump connections. The alarm must
be connected to a separate circuit. Additional pump details are on the design drawing. Advantex systems must
conform to the CDPHE technology approval letter dated May 1, 2018.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure functionality of the system. System certification, along with photos
and a record drawing is required to be submitted to, and approved by, Eagle County Environmental Health prior to
the use of the system or occupancy of the dwelling.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Claire Lewandowski
Date
September 25, 2020
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Friday, September 25, 2020 1
September 11th, 2020
Ms. Claire Lewandowski, REHS
Eagle County Environmental Health
590 Broadway
Eagle, CO 81631
RE: Frost Creek - Onsite Wastewater Treatment System Design – Lot 60, Eagle County, CO
Dear Claire:
JVA Inc. (JVA) has prepared a design of an onsite wastewater treatment system (OWTS) to
serve Lot 60 within the Frost Creek PUD. JVA is the designated engineer to process all OWTS
permit applications within Frost Creek. JVA has prepared the OWTS design to be in general
conformance with OWTS requirements of the PUD.
The 2019 annual Water Quality Monitoring Report prepared by Wright Water Engineers
documents exceedances of the 85th percentile background concentrations during sampling events
in 2019. The report states the following ‘The trends of water quality parameters seen throughout
the sampling of groundwater and surface water at the Frost Creek PUD have not reflected a
marked upward increase in concentrations of the sampled parameters. As more homes are
constructed on the Frost Creek PUD during 2020, the surface water and groundwater sampling
location will continue to be monitored’
Sincerely,
JVA, INCORPORATED
By: _______________________
Simon Farrell, P.E.
Project Manager, Associate
Attachment A - OWTS design – Lot 60
Attachment B - Visual and Tactile Soil Evaluation
Attachment C - Discharge pump calculations
FROST CREEK
LOT 60 ONSITE WASTEWATER TREATMENT SYSTEM
EAGLE COUNTY, COLORADO
PERMIT SET
SEPTEMBER 2020
Set No._______
JVA, Inc.1319 Spruce Street
www.jvajva.com
Boulder, CO 80302 303.444.1951
Boulder ● Fort Collins ● Winter Park
Glenwood Springs ● Denver
09/11/2020
LEGEND, NOTES AND ABBREVIATIONSG0.1 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY:
DRAWN BY:
CHECKED BY:
JOB #:
DATE:
© JVA, INC.FROST CREEKLOT 60 OWTSEAGLE, COLORADOSHEET NO.
1037.14e
SEPTEMBER 2020
SAF
AR/JNG
AR
JVA, Inc.1319 Spruce Street
www.jvajva.com
Boulder, CO 80302 303.444.1951
Boulder ● Fort Collins ● Winter Park
Glenwood Springs ● Denver
09/11/2020
7253.87
7251.50
7247.64
7243.45
7239.18
7235.47
7231.46
7227.47
7223.87
7228.58
7228.52
7228.64
7229.11 CIVIL SITE PLANC1.0 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY:
DRAWN BY:
CHECKED BY:
JOB #:
DATE:
© JVA, INC.FROST CREEKLOT 60 OWTSEAGLE, COLORADOSHEET NO.
1037.14e
SEPTEMBER 2020
SAF
AR/JNG
AR
JVA, Inc.1319 Spruce Street
www.jvajva.com
Boulder, CO 80302 303.444.1951
Boulder ● Fort Collins ● Winter Park
Glenwood Springs ● Denver
09/11/2020
TREATMENT SYSTEM AND SITE DETAILSCD1.0 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY:
DRAWN BY:
CHECKED BY:
JOB #:
DATE:
© JVA, INC.FROST CREEKLOT 60 OWTSEAGLE, COLORADOSHEET NO.
1037.14e
SEPTEMBER 2020
SAF
AR/JNG
AR
JVA, Inc.1319 Spruce Street
www.jvajva.com
Boulder, CO 80302 303.444.1951
Boulder ● Fort Collins ● Winter Park
Glenwood Springs ● Denver
09/11/2020
SOIL TREATMENT AREA DETAILSCD1.1 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY:
DRAWN BY:
CHECKED BY:
JOB #:
DATE:
© JVA, INC.FROST CREEKLOT 60 OWTSEAGLE, COLORADOSHEET NO.
1037.14e
SEPTEMBER 2020
SAF
AR/JNG
AR
JVA, Inc.1319 Spruce Street
www.jvajva.com
Boulder, CO 80302 303.444.1951
Boulder ● Fort Collins ● Winter Park
Glenwood Springs ● Denver
09/11/2020
September 11, 2020
Ms. Claire Lewandowski, REHS
Eagle County Environmental Health
590 Broadway
Eagle, CO 81631
RE: Frost Creek Lot 60 – Site and Soil Investigation Report for an Onsite Wastewater
Treatment System (OWTS)
JVA Job No. 1037.14e
Dear Claire:
Enclosed in this report are the results of the site and soil evaluation for Lot 60’s proposed OWTS
located in Frost Creek, Colorado. This report provides information needed to support the design
of an OWTS including: results from the preliminary investigation, the site visit, and the soil
evaluation. Design calculations are included in the drawing Permit Set attached.
PRELIMINARY INVESTIGATION
In preparation for a site visit and soil evaluation, a preliminary investigation was conducted the
week of November 8, 2019. Architectural site plans, aerial imagery, and previous Geotechnical
investigations were used for the preliminary investigation. Geotechnical investigations were
performed by HP Geotech in October 2002 across Frost Creek for OWTS suitability. Results from
the HP Geotech report showed that Test Hole A had a topsoil from zero to six inches deep, then a
clay layer to four feet, and a gravel-clay layer from four to eight feet deep. Test Hole B had a
topsoil from zero to six inches deep, then a clay layer to four feet deep, and a gravel-clay layer
from four to eight feet deep. No groundwater was encountered in either test holes.
SITE VISIT AND SOIL EVALUATION
A site visit and soil evaluation were conducted on November 8, 2019. The purpose of the site visit
and soil evaluation was to confirm hypotheses from the preliminary investigation, identify the
topography, landscape position, vegetation, and site constraints for the proposed OWTS, and to
conduct a visual and tactile soil evaluation of the underlying soils where the proposed soil
treatment area (STA) is to be located for both suitability and sizing.
The topography of the site slopes from west to east. The dominant vegetation at the proposed
OWTS consists of native grasses. Site Constraints are shown in the Permit Documents. For the
visual and tactile soil evaluation, two soil profile holes were excavated using a tracked excavator
in the locations identified in the Permit Documents. As seen in
Table 1 below, soil morphology for both Soil Profile Hole One and Two from zero to one feet
deep was consistent with a Soil Type 3, and from one to eight feet deep was Soil Type 2. No
redoximorphic features, indicating seasonally high ground water, were found in either holes.
Figures 1 through 4 below show the soil profile holes and corresponding morphology. Therefore,
Soil Type 2 was identified as the soil type.
Frost Creek Lot 60
Site and Soil Investigation
9/11/20
2 of 2
Table 1 – Visual and Tactile Soil Results
Profile
Hole
Depth
(ft.) Percent Rock Soil
Texture
Soil
Structure
Type
Soil
Structure
Grade
Soil
Type
1
0 – 1 0% retained on
20 mm sieve
0% retained
on 2 mm sieve
Sandy Clay
Loam Blocky Moderate 3
1 – 8 0% retained
on 20 mm sieve
0% retained
on 2 mm sieve Silt Loam Blocky Moderate 2
2
0 – 1 0% retained on
20 mm sieve
0% retained
on 2 mm sieve
Sandy Clay
Loam Blocky Moderate 3
1 – 8 0% retained
on 20 mm sieve
0% retained
on 2 mm sieve Silt Loam Blocky Moderate 2
Figure 1 – Profile Hole One
Figure 2 – Profile Hole One Soil Morphology
Figure 3 – Profile Hole Two Figure 4 – Profile Hole Two Soil Morphology
Sincerely,
JVA, INCORPORATED
By: _______________________
James Cochran, P.E.
Project Engineer
Job Name: Frost Creek Lot 60
Job Number: 1037.14e
Date: 9/9/2020
By: JNG
Line Variable Description Value Unit Note
Lateral Distribution Piping
Nlaterals Number of Laterals being feed by one pump cycle = 6.0 --
Llateral Lateral Length = 35 ft
Orifice Spacing = 2.0 ft Manual Input
Norifices Number of Orifices per Lateral = 18 --
Orifice Discharge and Total Flow
Corifice Orifice Discharge Coefficient = 0.63 -- Sharp Edge
Dorifice Diameter of Orifice = 0.13 in 1/8'' diameter orifice
g Acceleration due to Gravity = 32.2 ft/s2
hn Residual Head at last Orifice = 4.22 ft Chosen value.
Qn Discharge from Single Orifice = 0.40 gpm
= 2.45Corfice·(Dorfice)2·(2ghn)0.5
Qlateral Flow into Each Lateral = 6.96 gpm = Qn x Norifice
Qtotal Total Flow into Soil Treatment Area = 41.7 gpm
= Qlateral x Nlaterals
Headloss in Lateral Distribution Piping (Hazen-Williams)
Clateral Hazen-Williams Coefficient = 150 -- For PVC
dLateral Lateral Inside Diameter = 1.59 in For 1.5'' SCH 40
hlateral Headloss due to Friction in Lateral = 0.13 ft = 10.5Llateral·(Qlateral/Clateral)1.85·(dlateral)-4.87
hf-lateral Actual Headloss due to Friction in Lateral = 0.043 ft
= 1/3 x hlateral (Accounting for Orifices)
Headloss in Manifold (Hazen-Williams)
Lmanifold Length of Manifold = 9 ft Same as the STA Max Width
dmanifold Manifold Inside Diameter = 1.59 in For 1.5'' SCH 40
Cmanifold Hazen-Williams Coefficient = 150 -- For PVC
hmanifold Headloss due to Friction in Manifold = 0.92 ft
= 10.5Lmanifold·(Qtotal/Cmanifold)1.85·(dmanifold)-4.87
hf-manifold Actual Headloss due to Friction in Manifold = 0.31 ft = 1/3 x hmanifold (Accounting for Orifices)
Headloss in Delivery Piping (Hazen-Williams)
Lpipe Length of Delivery Pipe = 25 ft From Dosing chamber to manifold
dpipe Delivery Pipe Inside Diameter = 1.59 in For 1.5'' SCH 40
Cpipe Hazen-Williams Coefficient = 150 -- For PVC Pipe
hf-pipe Headloss due to Friction in Pipe = 2.57 ft
= 10.5Lpipe·(Qtotal/Cpipe)1.85·(dpipe)-4.87
Total Dynamic Head (Hazen-Williams)
hf-fittings Headloss due to Fittings = 2.88 ft One 90 deg bend to STA. Six 90 deg bends to laterals
Headloss through Automatic Distirbuting Valve = 23.00 ft
hs Static Head = 3.50 ft Max Elevation difference (typically in tank or to ADV)
TDH Total Dynamic Head = 36.52 ft = hs + hf-fittings + hf-pipe + hf-manifold + hf-lateral + hn
Volume of pipes
Delivery Pipe (drainback to tank) = 3 gal = ((3.14/4)*(dpipe/12)2*(Lpipe))*7.48
STA Laterals = 22 gal
= ((3.14/4)*(dpipe/12)2*(Lpipe))*7.49
Total Volume = 24 gal
Duty Point
Flowrate =42 gpm
Total Dynamic Head =37 ft
HUNTERS VIEW OWTS 6 (Lots 114 115 116)
PUMP CALCULATIONS
FC Lot 60 Pump Calculation - Pump Design Calculations Page 1 of 1
INSPECTION WORKSHEET (EAGLE AREA - 440 FROST CREEK - 513314)
FOR EAGLE COUNTY GOVERNMENT
OWTS-019702-2020Case Number:Case Module:Permit Management
03/09/2022 ApprovedInspection Status:Inspection Date:
OWTS Final InspectionInspection Type:Inspector:
Job Address:Parcel Number:440 Frost Creek Dr
Eagle Area, CO
210925302007
Company Name NameContact Type
Contractor Defina Construction, INC Gary Defina
Engineer JVA Inc Simon Farrell
Owner Ken and Mamie Jones
CommentsPassedChecklist Item
True This system is an Advantex treating at TL3N and considered
higher level treatment.
Higher Level Treatment System - Higher Level
Treatment System (when applicable)
True A Valley Precast 1,250 gallon, single compartment tank with
effluent screen and alarm placed on the outlet, followed by a 2,000
gallon Valley Precast 3-compartment recirculating/dose tank
which will send wastewater to two, Advantex AX-20 pods for
nitrification using an Orenco PF500512 pump was used.
Septic Tank - Septic Tank
True Received 3/8/2022 from JVA Inc.Record Drawing - Record Drawing
True Received 3/8/2022 from JVA Inc.Record Photos - Record Photos
True Received 9/22/2020 from JVA Inc.Site and Soil - Site & Soil
True Received 3/8/2022 from JVA Inc.Final Certification Letter - Final Certification Letter
True Received 9/22/2020 from JVA Inc.General Plan - General Plan
True The STA consists of two beds, each arranged with of three rows of
8 Infiltrator Quick 4 Plus Standard chambers for a total of 48
chambers. Distribution lateral details, along with orifice size,
spacing and orientation are on the design drawing.
Soil Treatment Area (STA) - Soil Treatment Area (STA)
True Defina Construction was the licensed installer.Identification of Systems Contractor - Identification of
Systems Contractor
March 09, 2022 Page 1 of 1P.O. Box 179, 500 Broadway, Eagle, CO 81631-0179
March 4, 2022
Claire Lewandowski, REHS, Environmental Health Specialist III
Eagle County Environmental Health
500 Broadway Street
Eagle, CO 81631
RE: Onsite Wastewater Treatment System Final Certification – 440 Frost Creek Drive, Lot 60
Dear Claire:
The Onsite Wastewater Treatment System (OWTS) covered under Eagle County Permit No.
OWTS-019702-2020 was installed by Defina Construction, Inc for 440 Frost Creek Drive. This
letter certifies that the construction of the OWTS was completed as per the approved design plan.
The final record drawings from JVA, and construction photographs are provided as attachments.
As part of the final approval process JVA observed that start-up was completed by the
manufacturer’s representative (Valley Precast, Inc), and completed a site visit to check all system
components. Although all unit processes function properly, the system cannot currently be
remotely monitored via Vericomm due to lack of internet infrastructure. CenturyLink is aware
of the issue and is upgrading the main panel in Eagle Spur. In the interim Frost Creek will have
a more concerted onsite effort by stopping biweekly to check the OWTS and respond to local
visual and audio alarms.
Sincerely,
JVA, INCORPORATED
By: ________________________
Simon Farrell, P.E.
Project Manager, Associate
Enclosure:
Attachment A – Record Drawings
Attachment B – Construction Photographs
CC: Julie Gustavson, JVA
ATTACHMENT A – RECORD DRAWINGS
ATTACHMENT B – CONSTRUCTION PHOTOGRAPHS
Lot 60