Permit
Permit No. OWTS-018817-2020
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 6/2/2020 Expires: 9/30/2020
On-Site Wastewater
Treatement System
Project Address Parcel Number
426 SQUIRES LN, EAGLE AREA,210935101002
Owner Information Address
Mark and Deborah Spiers 427 Garfield ST
Denver, CO 80206
Phone: (908) 304-2305
Cell:
Email: msspiers@gmail.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
JVA Inc, Simon Farrell (303) 444-1951 sfarrell@jvajva.com
Contractor License Number Phone Email
Permitted Construction / Details:
A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County
(EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor
without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503,
C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS.
Install the OWTS exactly as depicted in the JVA, Inc. design stamped, signed and dated April 7, 2020 by Simon A.
Farrell, PE. The OWTS is designed with capacity to serve a 5 bedroom residence.
The system consists of a Valley Precast 1,250 gallon, single compartment tank with effluent screen and alarm placed
on the outlet, followed by a 2,000 gallon Valley Precast three-compartment recirculating/dose tank which will send
wastewater to two, Advantex AX 20 pods for nitrification using an Orenco PF 500512 pump. Nitrified effluent flows to
the splitter valve for recirculation to the 1,250 gallon first tank for denitrification then is dosed using an Orenco PF
751012 pump to 1728 square feet of soil treatment area via two beds each consisting of four rows of 18 Infiltrator
Quick 4 Plus Standard chambers for a total of 144 Infiltrator chambers, set atop two feet of sand filter media that
meets a gradiation of prefferred or secondary media as defined in 43.11.C.2.
Note: Gradation of the sand media use must be completed within one month prior to the installation and confirmed
with the design engineer. If the sand does not conform to secondary or preferred sand media requirements, it
cannot be used for the sand treatment media.
Distribution lateral details, along with orifice size, spacing and orientation are on the design drawing. The contractor
must verify that all electrical components and inspections are covered under the electrical permit associated with
the Orenco Vericom control panel (Model VCOM-AX20B2) and pump connections. The alarm must be connected to a
separate circuit. Additional pump details are on the design drawing. Advantex systems must conform to the
CDPHE technology approval letter dated May 1, 2018.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure functionality of the system. System certification, along with photos
and a record drawing is required to be submitted to, and approved by, Eagle County Environmental Health prior to
the use of the system or occupancy of the dwelling.
Tuesday, June 2, 2020 1
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Claire Lewandowski
Date
June 02, 2020
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Tuesday, June 2, 2020 2
***************************************************************************
APPLICATION FOR ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS) PERMIT
INCOMPLETE APPLICATIONS MAY NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEE SCHEDULE
APPLICATION FEE FOR NEW OWTS OR MAJOR REPAIRS $800.00 MINOR REPAIR FEE $400.00
Fee includes the design review, permitting and maintenance of OWTS records
Make all checks payable to: Eagle County Treasurer
Property Owner: _______________________________________Phone: ________________________
Owner Mailing Address: ________________________________ email: _________________________
Professional Engineer: __________________________________ Phone: ________________________
Applicant / Contact Person: ______________________________Phone: ________________________
Licensed Systems Contractor Name / Company: ___________________________________________
Contractor Mailing Address: _________________________________ Contractor License #:_______
Contractor Phone Number: ________________________ email: ______________________________
OWTS Permit Application is for: ____ New Installation ____ Alteration ____ Repair
Tax Parcel Number: _________________________________ Lot Size: ________________________
Assessor’s Link: www.eaglecounty.us/patie/
Physical Address: _____________________________________________________________________
Legal Description: ____________________________________________________________________
Building Type: _____ Residential / Single Family
_____ Residential / Multi Family
_____ Commercial / Industrial
Number of Bedrooms: ______
Number of Bedrooms: ______
Type of Use: _______________
*As of 06/27/2014, all systems require design by a Registered Professional Engineer.
Type of Water Supply: ____ Private Well ____ Spring ____ Surface ____ Public
If Public, Name of Supplier: ____________________________________________________________
Applicant Signature: ______________________________________Date:_______________________
****************************************************************************
Office Use Only: OWTS PERMIT # __________________ BUILDING PERMIT # ____________________
Amount Paid: ___________ Receipt #: ___________ Check #: ___________ Date: ______________
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.eaglecounty.us
P.O. Box 179
500 Broadway
Eagle, CO 81631
environment@eaglecounty.us
April 8, 2020
Ms. Claire Lewandowski, REHS
Eagle County Environmental Health
590 Broadway
Eagle, CO 81631
RE: Frost Creek - Onsite Wastewater Treatment System Design – Lot 3, Eagle County, CO
Dear Claire:
JVA Inc. (JVA) has prepared a design of an onsite wastewater treatment system (OWTS) to
serve Lot 3 within the Frost Creek PUD. JVA is the designated engineer to process all OWTS
permit applications within Frost Creek. JVA has prepared the OWTS design to be in general
conformance with OWTS requirements of the PUD.
The 2019 annual Water Quality Monitoring Report prepared by Wright Water Engineers
documents exceedances of the 85th percentile background concentrations during sampling events
in 2019. The report states the following ‘The trends of water quality parameters seen throughout
the sampling of groundwater and surface water at the Frost Creek PUD have not reflected a
marked upward increase in concentrations of the sampled parameters. As more homes are
constructed on the Frost Creek PUD during 2020, the surface water and groundwater sampling
location will continue to be monitored’
Sincerely,
JVA, INCORPORATED
By: _______________________
Simon Farrell, P.E.
Project Manager, Associate
Attachment A - OWTS design – Lot 3
Attachment B - Visual and Tactile Soil Evaluation
Attachment C - Discharge pump calculations
ATTACHMENT A – OWTS DESIGN – LOT 3
ATTACHMENT B – VISUAL AND TACTILE SOIL
EVALUATION
April 8, 2020
Ms. Claire Lewandowski, REHS
Eagle County Environmental Health
590 Broadway
Eagle, CO 81631
RE: Frost Creek Lot 3 – Site and Soil Investigation Report for an Onsite Wastewater
Treatment System (OWTS)
JVA Job No. 1037.9e
Dear Claire:
Enclosed in this report are the results of the site and soil evaluation for Lot 3’s proposed OWTS
located in Frost Creek, Colorado. This report provides information needed to support the design
of an OWTS including: results from the preliminary investigation, the site visit, and the soil
evaluation. Design calculations are included in the drawing Permit Set attached.
PRELIMINARY INVESTIGATION
In preparation for a more efficient and informed site visit and soil evaluation, a preliminary
investigation was conducted the week of October 1st, 2019. Aerial imagery, and previous
Geotechnical investigations were used for the preliminary investigation. Geotechnical
investigations were performed by HP Geotech in October 2002 across Frost Creek for OWTS
suitability; this geotechnical investigation has been submitted to Eagle County previously. Results
from the HP Geotech report showed that Test Hole A and B had a topsoil from zero to six inches
deep, then a clay layer to four feet, and a gravel-clay layer from four to eight feet deep. No
groundwater was encountered in either test holes.
SITE VISIT AND SOIL EVALUATION
A site visit and soil evaluation were conducted on October 8th, 2019 by James Cochran; James has
passed the CPOW Soils Evaluation Course. The purpose of the site visit and soil evaluation was
to confirm hypotheses from the preliminary investigation, identify the topography, landscape
position, vegetation, and site constraints for the proposed OWTS, and to conduct a visual and
tactile soil evaluation of the underlying soils where the proposed soil treatment area (STA) is to
be located for both suitability and sizing.
The topography of the site slopes from west to east, and the dominant vegetation consists of native
grasses. Site Constraints are shown in the Permit Documents. For the visual and tactile soil
evaluation, two soil profile holes were excavated using a tracked excavator. As seen in Table 1
below, Soil Type R-2 was identified as the soil type. No redoximorphic features, indicating
seasonally high ground water, were found in either holes. Figures 1 through 4 below show the soil
profile holes and corresponding morphology. The proposed STA will be an unlined sand filter
with beds.
Frost Creek Lot 3
Site and Soil Investigation
4/8/20
2 of 2
Table 1 – Visual and Tactile Soil Results
Profile
Hole
Depth
(ft.) Percent Rock Soil
Texture
Soil
Structure
Type
Soil
Structure
Grade
Soil
Type
1
0 – 2 0% retained on
20 mm sieve
5% retained
on 2 mm sieve
Sandy
Loam Blocky Moderate 3
2 – 3 90% retained
on 20 mm sieve
10% retained
on 2 mm sieve
Sandy
Loam Blocky Moderate R-2
2
0 – 3 0% retained on
20 mm sieve
5% retained
on 2 mm sieve
Sandy
Loam Blocky Moderate 3
3 – 6 90% retained
on 20 mm sieve
10% retained
on 2 mm sieve
Sandy
Loam Blocky Moderate R-2
Figure 1 – Profile Hole One Figure 2 – Profile Hole One Soil Morphology
Figure 3 – Profile Hole Two Figure 4 – Profile Hole Two Soil Morphology
Sincerely,
JVA, INCORPORATED
By: _______________________
James Cochran, P.E.
Project Engineer
ATTACHMENT C – DISCHARGE PUMP
CALCULATIONS
Pump Selection for a Pressurized System - Single Family Residence Project
Frost Creek Lot 3
Parameters
Discharge Assembly Size
Transport Length
Transport Pipe Class
Transport Line Size
Distributing Valve Model
Max Elevation Lift
Manifold Length
Manifold Pipe Class
Manifold Pipe Size
Number of Laterals per Cell
Lateral Length
Lateral Pipe Class
Lateral Pipe Size
Orifice Size
Orifice Spacing
Residual Head
Flow Meter
'Add-on' Friction Losses
2.00
130
40
2.00
None
7
12
40
1.50
8
78
40
1.50
1/8
3
3.75
None
0
inches
feet
inches
feet
feet
inches
feet
inches
inches
feet
feet
inches
feet
Calculations
Minimum Flow Rate per Orifice
Number of Orifices per Zone
Total Flow Rate per Zone
Number of Laterals per Zone
% Flow Differential 1st/Last Orifice
Transport Velocity
0.38
216
81.5
8
2.5
7.8
gpm
gpm
%
fps
Frictional Head Losses
Loss through Discharge
Loss in Transport
Loss through Valve
Loss in Manifold
Loss in Laterals
Loss through Flowmeter
'Add-on' Friction Losses
13.3
12.8
0.0
1.1
0.2
0.0
0.0
feet
feet
feet
feet
feet
feet
feet
Pipe Volumes
Vol of Transport Line
Vol of Manifold
Vol of Laterals per Zone
Total Volume
22.7
1.3
65.9
89.9
gals
gals
gals
gals
Minimum Pump Requirements
Design Flow Rate
Total Dynamic Head
81.5
38.2
gpm
feet
0 20 40 60 80 100
0
20
40
60
80
100
Net Discharge (gpm)
PumpData
PF7515 High Head Effluent Pump
75 GPM, 1-1/2HP
230V 1Ø 60Hz
PF7515 High Head Effluent Pump
75 GPM, 1HP
230V 1Ø 60Hz
Legend
System Curve:
Pump Curve:
Pump Optimal Range:
Operating Point:
Design Point:
INSPECTION WORKSHEET (EAGLE AREA - 426 SQUIRES - 508451)
FOR EAGLE COUNTY GOVERNMENT
OWTS-018817-2020Case Number:Case Module:Permit Management
07/08/2021 ApprovedInspection Status:Inspection Date:
OWTS Final InspectionInspection Type:Inspector:Claire Lewandowski
Job Address:Parcel Number:426 Squires Ln
Eagle Area, CO
210935101002
Company Name NameContact Type
Contractor Vailterra Construction Abraham Alvarado
Engineer JVA Inc Simon Farrell
Owner Mark and Deborah Spiers
CommentsPassedChecklist Item
TrueDosing Chamber/Tank - Dosing Chamber/Tank (when
applicable)
TrueHigher Level Treatment System - Higher Level
Treatment System (when applicable)
True Inspected 7/8/2021, 1250 gallon Valley Precast single
compartment tank with an effluent screen and alarm placed on the
outlet followed by a 2000 gallon Valley Precast three compartment
recirculating/dose tank which will send wastewater to two
Advantex AX@) pods for nitrification using an Orenco PF 500512
pump.
Septic Tank - Septic Tank
TrueRecord Drawing - Record Drawing
TrueRecord Photos - Record Photos
True Received 6/3/2020 from JVA Inc.Site and Soil - Site & Soil
True Final Certification provided by JVA, dated October 22, 2021, signed
by Simon Farrell, PE.
Final Certification Letter - Final Certification Letter
True Received 6/3/2020 from JVA Inc.General Plan - General Plan
True Inspected 7/8/2021, 2 beds of 4 row rows of 18 chambers for a
total of 144.
Soil Treatment Area (STA) - Soil Treatment Area (STA)
True Vailterra Construction was the licensed installer.Identification of Systems Contractor - Identification of
Systems Contractor
November 03, 2021 Page 1 of 1P.O. Box 179, 500 Broadway, Eagle, CO 81631-0179
October 22, 2021
Claire Lewandowski, REHS, Environmental Health Specialist III
Eagle County Environmental Health
500 Broadway Street
Eagle, CO 81631
RE: Onsite Wastewater Treatment System Final Certification – 426 Squires Lane, Lot 3
Dear Claire:
The Onsite Wastewater Treatment System (OWTS) covered under Eagle County Permit No.
OWTS-018817-2020 was installed by Turnipseed for 426 Squires Lane and is ready for final
certification from Eagle County Environmental Health. The engineer of record for this system is
Simon Farrell with JVA, Inc (JVA). The final record drawings from JVA, and construction
photographs are provided as attachments.
As part of the final approval process JVA ensured that start-up was completed by the
manufacturer’s representative (Valley Precast, Inc). The system is connected and can be
monitored remotely as required in the PUD.
Please proceed with the closeout process for this OWTS permit.
Sincerely,
JVA, INCORPORATED
By: ________________________
Simon Farrell, P.E.
Associate
Enclosure:
Attachment A – Record Drawings
Attachment B – Construction Photographs
CC: Julie Gustavson, JVA
ATTACHMENT A – RECORD DRAWINGS
FROST CREEK
LOT 3 ONSITE WASTEWATER TREATMENT SYSTEM
EAGLE COUNTY, COLORADO
PERMIT SET
APRIL 2020
Set No._______
JVA, Inc.1319 Spruce Street
www.jvajva.com
Boulder, CO 80302 303.444.1951
Boulder ● Fort Collins ● Winter Park
Glenwood Springs ● Denver
GENERAL NOTESG0.1 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY:
DRAWN BY:
CHECKED BY:
JOB #:
DATE:
© JVA, INC.FROST CREEKLOT 3 OWTSEAGLE, COLORADOSHEET NO.
1037.9e
APRIL 2020
SAF
JRC
JRC
JVA, Inc.1319 Spruce Street
www.jvajva.com
Boulder, CO 80302 303.444.1951
Boulder ● Fort Collins ● Winter Park
Glenwood Springs ● Denver
CONFORMED TO CONSTRUCTION RECORD 10/2021CLFCLFRECORD DRAWINGS1
CIVIL SITE PLANC1.0 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY:
DRAWN BY:
CHECKED BY:
JOB #:
DATE:
© JVA, INC.FROST CREEKLOT 3 OWTSEAGLE, COLORADOSHEET NO.
1037.9e
APRIL 2020
SAF
JRC
JRC
JVA, Inc.1319 Spruce Street
www.jvajva.com
Boulder, CO 80302 303.444.1951
Boulder ● Fort Collins ● Winter Park
Glenwood Springs ● Denver
CONFORMED TO CONSTRUCTION RECORD
10/2021CLFCLFRECORD DRAWINGS1
TREATMENT SYSTEM AND SITE DETAILSCD1.0 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY:
DRAWN BY:
CHECKED BY:
JOB #:
DATE:
© JVA, INC.FROST CREEKLOT 3 OWTSEAGLE, COLORADOSHEET NO.
1037.9e
APRIL 2020
SAF
JRC
JRC
JVA, Inc.1319 Spruce Street
www.jvajva.com
Boulder, CO 80302 303.444.1951
Boulder ● Fort Collins ● Winter Park
Glenwood Springs ● Denver
CONFORMED TO CONSTRUCTION RECORD
10/2021CLFCLFRECORD DRAWINGS1
SOIL TREATMENT AREA DETAILSCD1.1 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY:
DRAWN BY:
CHECKED BY:
JOB #:
DATE:
© JVA, INC.FROST CREEKLOT 3 OWTSEAGLE, COLORADOSHEET NO.
1037.9e
APRIL 2020
SAF
JRC
JRC
JVA, Inc.1319 Spruce Street
www.jvajva.com
Boulder, CO 80302 303.444.1951
Boulder ● Fort Collins ● Winter Park
Glenwood Springs ● Denver
CONFORMED TO CONSTRUCTION RECORD 10/2021CLFCLFRECORD DRAWINGS1
ATTACHMENT B – CONSTRUCTION PHOTOGRAPHS
Lot 3
Sand Gradation Analysis Spreadsheet.xlsx
GRADATION ANALYSIS TEST
ENTER INFORMATION IN BLUE CELLS
LABORATORY TEST REPORT DATA
GRADATION RESULTS COMPARED TO PREFERRED AND SECONDARY SAND FILTER SPECIFICATIONS
Parameter Value Units
Preferred
Sand
Value
Pass / Fail
Preferred
Sand
Secondary
Sand Value
Pass / Fail
Secondary
Sand
Laboratory United Companies
Client:
Location / Plant:102_01202-Eagle
Sample / Product:14111-Gypsum 1/4" Concrete Sand
Sample Date:04/20/2021 - 05/20/2021
Lab Test Date:
Job Number:
SIEVE SIEVE OPENING IN
MILLIMETERS
PERCENT
PASSING THRU
SIEVE
3"75 100.0
1.5 37.5 100.0
3/4"19 100.0
3/8"9.5 99.0
No. 4 4.75 97.0
No. 8 2.36 81.0
No. 16 1.18 63.0
No. 30 0.6 41.0
No. 50 0.3 19.0
No. 100 0.15 6.0
No. 200 0.075 2.3
D60 - Diameter that 60 percent of the
sample is finer than.1.10 millimeters
Effective Size - D10 - Diameter that 10
percent of the sample is finer than.0.196 millimeters 0.25 to 0.60 0.15 to 0.60 PASS
Uniformity Coefficient (D60 / D10)5.61 unitless ratio < or = 4.0 < or = 7.0 PASS
Percent passing thru #200 Sieve 2.3 millimeters < or = 3 PASS < or = 3 PASS
FAIL
FAIL
Diameter of Particle in MillimetersPercent Passing Sieve0
10
20
30
40
50
60
70
80
90
100
75 37.5 19 9.5 4.75 2.36 1.18 0.6 0.3 0.15 0.075
Plot of Gradaon Analysis