Permit
Permit No. OWTS-021231-2021
Permit Type: OWTS Permit
Work Classification: Alteration
Permit Status: Active
Issue Date: 4/29/2021 Expires: 8/27/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
554 ESCALANTE, EL JEBEL AREA,239127207005
Owner Information Address
Jacquelyn Lefebvre Phone:
Cell: (508) 221-3562
Email: nantucketjuicebar@yahoo.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Zamora Excavating Inc gerryzamora@msn.com(970) 379-7171OWTSPL-000117-20
21
Permitted Construction / Details:
Replace the septic tank originally permitted under 0196IS exactly as depicted in the CBO Inc design dated April 21st,
2021, stamped and signed on April 26th, 2021 by Romeo Baylosis PE.
The replacement tank is 1,060 gallon two compartment Roth poly septic tank with an effluent filter on the outlet tee.
The elevation of the tank placement must align with the existing sewer line exiting the residence and the existing
sewer line to the STA. Risers must be added as necessary to bring both access manholes to or above grade. Install
a double-sweep clean out as specified on the design drawings between the tank and the house. Replace cast iron
sewer pipe as necessary with SDR-35. The old tank is to be abandoned in place as specified in 43.9(C.). Be sure to
stake soil treatment area to prevent soil compaction from heavy equipment or tank staging.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Sell
Date
April 29, 2021
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Thursday, April 29, 2021 1
Inspection Result
Eagle County, Colorado
P.O. Box 179 500 Broadway Eagle, CO
Phone: (970) 328-8730 Fax: (970) 328-7185
IVR Phone: 1-866-701-3307
Inspection Number: INSP-525072-2023 Permit Number: OWTS-021231-2021
Inspection Date: 08/31/2023
Inspector:
Permit Type: OWTS Permit
Inspection Type: OWTS Final Inspection
Work Classification: AlterationOwner:Homemade LLC
Job Address:554 ESCALANTE IVR Pin Number:192911
EL JEBEL AREA, CO Project:<NONE>
Parcel Number:239127207005
Contractor:Phone: (970) 963-1399 / Cell: (970) 379-7171Zamora Excavating Inc
Inspection Status: Approved
Inspection Notes
Inspector Comments
Added Item: Septic Tank
A new, 1000-gallon, two-compartment Roth® poly septic tank with an Orenco Biotube Effluent filter on
the outlet tee was installed. The existing tank was abandoned in place.
Added Item: Record Drawing
Received 8/31/2023 from CBO Inc.
Added Item: Record Photos
Received 8/31/2023 from CBO Inc.
Added Item: Site and Soil
Received 4/27/2021 from CBO Inc.
Added Item: Final Certification Letter
Received 8/31/2023 from CBO Inc.
Added Item: General Plan
Received 4/27/2021 from CBO Inc.
Added Item: Soil Treatment Area (STA)
The existing STA from 1977 remains with no evidence of malfunctioning.
Added Item: Identification of Systems Contractor
Zamora Excavating was the licensed installer.
Thursday, August 31, 2023
For more information visit: http://www.eaglecounty.us
Page 1 of 2
Thursday, August 31, 2023
For more information visit: http://www.eaglecounty.us
Page 2 of 2
CBO Inc.
129 Cains Lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
April 3, 2023 Project No. C1600
Jackie Lefebvre
nantucketjuicebar@yahoo.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
554 Escalante
Eagle County, Colorado
Permit Number OWTS-021231-2021
Jackie,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) in the early
summer 2021 and April 3, 2023 for the subject property. Zamora Excavating installed the system.
The existing septic tank was pumped, collapsed, and the remaining void filled with onsite material.
The original OWTS was sized for 3 bedrooms in 1977. The residence has 3 bedrooms currently.
The existing cast iron sewer line was replaced to the house foundation. The 4-inch diameter SDR-35
PVC sewer line had a minimum 2% fall to the septic tank and a double-sweep clean out.
A new, 1000-gallon, two-compartment Roth® poly septic tank with an Orenco Biotube Effluent filter on
the outlet tee was installed. This filter must be cleaned annually, or as needed. Risers bring the
manhole lids to grade.
A new 4-inch SDR-35 sewer line was installed from the septic tank and tied into the existing sewer line
approximately 15-feet from the new septic tank. The existing STA from 1977 remains with no evidence
of malfunctioning.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent on the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc.
Carla Ostberg, MPH, REHS
View of new sewer line and new septic tank / Septic tank bedded in sand
Final grading around septic tank View of septic tank lids
New sewer line with clean out View of septic tank lids
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-021231-2021
Permit Type: OWTS Permit
Work Classification: Alteration
Permit Status: Active
Issue Date: 4/29/2021 Expires: 8/27/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
554 ESCALANTE, EL JEBEL AREA,239127207005
Owner Information Address
Jacquelyn Lefebvre Phone:
Cell: (508) 221-3562
Email: nantucketjuicebar@yahoo.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Zamora Excavating Inc gerryzamora@msn.com(970) 379-7171OWTSPL-000117-20
21
Permitted Construction / Details:
Replace the septic tank originally permitted under 0196IS exactly as depicted in the CBO Inc design dated April 21st,
2021, stamped and signed on April 26th, 2021 by Romeo Baylosis PE.
The replacement tank is 1,060 gallon two compartment Roth poly septic tank with an effluent filter on the outlet tee.
The elevation of the tank placement must align with the existing sewer line exiting the residence and the existing
sewer line to the STA. Risers must be added as necessary to bring both access manholes to or above grade. Install
a double-sweep clean out as specified on the design drawings between the tank and the house. Replace cast iron
sewer pipe as necessary with SDR-35. The old tank is to be abandoned in place as specified in 43.9(C.). Be sure to
stake soil treatment area to prevent soil compaction from heavy equipment or tank staging.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Sell
Date
April 29, 2021
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Thursday, April 29, 2021 1
832‐R‐13‐002
33 Four Wheel Drive Road
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
April 21, 2021 Project No. C1600
Jackie Lefebvre
nantucketjuicebar@yahoo.com
Onsite Wastewater Treatment System Septic Tank Replacement Design
3-Bedroom Residence
554 Escalante
Eagle County, Colorado
Jackie,
CBO Inc. completed an onsite wastewater treatment system (OWTS) septic tank replacement design for
the subject residence. The property is located outside of Basalt, in an area where OWTSs are
necessary.
Legal Description: Subdivision: ASPEN MESA ESTATES FIL 1 LOT:35
Parcel ID: 2391-272-07-005
SITE CONDITIONS A 3-bedroom, single-family residence presently exists and is utilizing an existing OWTS. The OWTS is
documented by Eagle County Permit No. 196 which received final approval on August 5, 1977. The
OWTS was inspected by Joe Zamora on November 19, 2020 and the septic tank was found to have
significant deterioration on the outlet side of the septic tank. There is a desire to replace the septic tank
at this time.
The residence is served potable water form a community water system. The proposed septic tank will
not come within 25-feet of the water line.
The existing soil treatment area (STA) appeared to be functioning normally. The intent is to continue to
use the existing STA.
DESIGN SPECIFICATIONS The existing septic tank will be abandoned in place. The septic tank must be pumped, collapsed, and
remaining void filled with gravel, sand, or compacted soil.
Design Calculations:
3 bedrooms = min. 1000-gallons septic tank capacity
The existing cast iron sewer line must be replaced to the house foundation. The 4-inch diameter SDR-35
PVC sewer line must have a minimum 2% fall to the septic tank and a double-sweep clean out.
A new, Roth® poly two-compartment septic tank with an Orenco Biotube Effluent filter on the outlet tee
must be installed. Risers must bring the manhole lids to grade. We recommend Orenco® risers and lids.
If more than 1-foot of risers are installed, a handle extension must be added to the effluent filter.
Page 2
For the purposes of this OWTS design, Benchmark Elevation has been established as 100’ as the sewer
line exiting the residence. Elevation of the septic tank placement must align with the existing sewer
line exiting the residence and the existing sewer line to the STA. CBO Inc. should be notified of any
discrepancies or problems with grade elevations of proposed components during installation of the
OWTS.
Any cast iron pipe after the septic tank should also be replaced with minimum SDR-35 sewer line with a
minimum 1% fall to the existing STA. We recommend testing the STA with approximately 100 gallons of
water to assure it is accepting effluent properly.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
COMPONENT MANUFACTURER MODEL NO. COMMENTS
Septic Tank Roth Model MRT-1060 2-compartment poly
septic tank
Tank Risers and Lids Orenco® Double-walled PVC Risers and Lids (24” diameter)
Effluent Filter Orenco® Full size effluent filter
Construction must be according to Eagle County On-Site Wastewater Treatment System Regulations, the
OWTS Permit provided by Eagle County Environmental Health Department, and this design.
INSTALLATION CONTRACTOR
CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours
in advance to observe the installation.
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
Page 3
4-26-2021
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, CBO Inc. should be notified. All OWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Please call with questions.
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE
N
SCALE: 1 = 50'=0"
\::ilIIi!iIIlIIi[:�:::/1:::t:::.{,;:::�:;-_-,. __
DRAWINGS MUST BE USED IN
CONJUNCTION WITH DESIGN
LETTER DATED 04/21/2021
@ � i:�::.:,\li�liil!!!!�I[ {!ill11!l(ll�li!!lii)§l!;\e;
I ·:,/:,>':>,I ill!!i!I I I 3 BEDROOM I RESIDENCE
I
EXISTING----...._
SEPTIC TANK
TO BE
ABANDONED
...
APPROX.
STA
I I I I I I Lot 35
l 1.50 acres as platted (DSITE PLAN
33 Four Wheel Drive Road
Carbondale, Colorado 81623
Phone 970.309.5259
carla@allserviceseptic.com
1'=501 -01
WATER Tl
SLIP-ON PVC CAP
DO NOT GLUE
INSULATED COPPER
TRACER WIRE
4" DIA SDR-35--�
SEWER LINE
G STA to REMAIN
i
i i i i i i i i i i i i i
@CLEAN OUT DE��lh--
FINISHED GRADE
4" DIA SDR-35 SEWER LINE
(MIN 2% SLOPE TO TANK,
MIN.1% TO STA)
SCREENED ROCK----
OR SAND FOR --i���� BEDDING
8" MIN.
3" MIN.
@lRENCH DETAILllff 16 !l!Ai1
' =::..:=..:»1111.0'.nn.• ·-
Homemade LLC
554 Escalante
Eagle County, Colorado
Project Number: C1600
Date: 04/21/2021
Designed by: CBO
Reviewed by: RB
W1.0
Sheet 1 OF 2
• Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
• Installs in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
• Easy to clean by
simply hosing off
whenever the tank
needs pumping
• Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
• Corrosion-proof
construction, to
ensure long life
• Lifetime warranty
Residential Biotube® Effluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a lifetime warranty. They prevent large solids from leaving
the tank, dramatically improving wastewater quality and extending the life
of residential drainfields.
Standard Features & Benefits
• Alarm available, to
signal the need for
cleaning
• Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
• Custom and
commercial sizes
available
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes’ entire
surface for filtering.
Particles larger than
the Biotube’s mesh
are prevented from
leaving the tank.
Optional
Features &
Benefits
Biotube
Filtering
Process
8-in. (200-mm)
Base Inlet Filter
4-in. (100-mm)
Insert Filter
4-in. (100-mm) Biotube Jr.
(4-in. Biotube cartridge avail-
able separately as Insert Filter)
Orenco’s superior effluent filters resist clogging better than all other brands. Our stan-
dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term
protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at
half the size of our standard model, has more filtering capacity than the full-sized filters
sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter
is ideal. And for low-profile tanks, there’s the Base Inlet Filter.
* Covered by patent numbers 5,492,635 and 4,439,323
4-in. (100-mm) Biotube Effluent Filter
APS-FT-1
Rev. 3.4 © 11/10
Orenco Systems®, Inc.
To Order
Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on
“Distributor Locator.”
Nomenclatures
Riser
wall
Tank wall
Filter housing
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube® filter cartridge
Solid base
4-in. Biotube
Effluent Filter
4-in. Biotube Jr.
4-in. Biotube Filter (standard)
4-in. Biotube Jr. (includes cartridge and housing)
Distributed By:
8-in. Biotube Filter (base inlet model)
4-in. Biotube Filter Insert (cartridge only)
Junior series
FT J0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Blank = 1/8" filtration
P = 1/16" filtration
Insert
FT i0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
-
For customized options (e.g., NC
indicates North Carolina regions)
-
Blank = 1/8" filtration
P = 1/16" filtration
FT 04
Biotube effluent filter series
Filter diameter (inches)
Housing height: 36" and 44" are standard
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Cartridge height: 28" and 36" are standard
-
Blank = 1/8" filtration
P = 1/16" filtration
W = fits Type 3034 outlet pipe
S = fits Schedule 40 outlet pipe
FT 2208 14 B
Biotube effluent filter series
Housing height: 22" standard
Cartridge height: 14" standard
Options:
A = float bracket
FS = 2" outlet orifice
FSO = 2" outlet orifice and overflow plate*
Base inlet model
-
Blank = 1/8" filtration
P = 1/16" filtration
Filter diameter (inches)
08 = 8"
* Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT
554 Escalante
W rite a des c ription for your m ap.
Legend
554 Es c alante Rd
200 ft
N➤➤N
HOMEMADE LLC
26 LOVERS LN
NANTUCKET, MA 02554-2842
Account: R031608
Tax Area: 007 - EL JEBEL (AREA) -
007
Acres: 1.500
Parcel: 2391-272-07-005
Situs Address:
000554 ESCALANTE
EL JEBEL AREA, 0
Value Summary
Value By:Market Override
Land (1)$190,000 N/A
Single Family
Residence (1)
$658,970 N/A
Extra Feature (1)$3,520 N/A
Total $852,490 $852,490
Legal Description
Subdivision: ASPEN MESA ESTATES FIL 1 Lot: 35
Sale Data
Doc. #Sale Date Deed Type Validity Verified Sale Price Ratio Adj. Price Ratio Time Adj.
Price
Ratio
202025674 12/22/2020 SWD N $842,000 101.25 $842,000 101.25 $842,000 101.25
B: 000693 P:
000374
04/15/1996 WD QV Y $450,000 189.44 $450,000 189.44 $450,000 189.44
Land Occurrence 1
Abstract Code 1112 - SINGLE FAM.RES.-LAND Percentage 100.0
Use Code 1000 - RESIDENTIAL Neighborhood 1010 - OAK RIDGE I
Land Code 9057 - FOX RUN MEADOWS Super Neighborhood 900 - BASALT / EL JEBEL AREA
Size 1.5
SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT
Land L 1
Total 1.00
Value Rate Rate Rate Rate
Property Record Card
Eagle County
A#: R031608 P#: 239127207005 As of: 04/25/2021 Page 1 of 3
Land Occurrence 1
$190,000 190,000.00
Single Family Residence Occurrence 1
Abstract Code 1212 - SINGLE FAM.RES-
IMPROVEMTS
Percentage 100.0
Use Code 1000 - RESIDENTIAL Neighborhood 1010 - OAK RIDGE I
Building Type 121200 - SFR Arch Style 3 - 2 STORY
Exterior Wall 16 - FR STUCCO Percentage 100.0
Roof Cover 5 - METAL Roof Structure 2 - SHED
Interior Wall 5 - DRYWALL Percentage 100.0
Floor 12 - HARDWOOD
14 - CARPET INV
Percentage 20.0
80.0
Heating Fuel 3 - GAS Heating Type 3 - FORCED AIR
Air Conditioning 1 - NONE Actual Year Built 1977
Bedrooms 3 Bathrooms 3
Construction Quality 3 - FAIR Effective Year Built 2000
Fixtures 13 Rooms 8
Units 1 Units 1
Super Neighborhood 900 - BASALT / EL JEBEL AREA Stories 3 - STORIES 3.0
Use Code 1000 - RESIDENTIAL Garage 4 - GARAGE 1101-1250
SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT
BAS 1428.0 1428.0 1428.0 1428.0
FBM 1428.0 1142.4 1428.0 1428.0
FOP 298.0 89.4 298.0
FUS 357.0 357.0 357.0 357.0
GDF 1200.0 1200.0
PTO 420.0 42.0 420.0
UDU 551.0 220.4 551.0
WDD 699.9 140.0 699.9
Total 6,381.90 3,419.20 3,213.00 6,381.90
Value Rate Rate Rate Rate
$658,970 103.26 192.73 205.09 103.26
Property Record Card
Eagle County
A#: R031608 P#: 239127207005 As of: 04/25/2021 Page 2 of 3
Single Family Residence Occurrence 1
Sketch by Apex IV™24.0'50.0'24.0'50.0'
GDF
1200.0 ft²29.0'19.0'29.0'19.0'
UDU
551.0 ft²17.0'21.0'17.0'21.0'
FUS
357.0 ft²21.0'14.0'17.0'21.0'17.0'14.0'21.0'14.0'2.0'21.0'2.0'14.0'
FBM
1428.0 ft²8.0'21.0'8.0'FOP
168.0 ft²20.0'21.0'20.0'21.0'
PTO
420.0 ft²21.0'14.0'17.0'21.0'17.0'14.0'21.0'14.0'2.0'21.0'2.0'14.0'
BAS
1428.0 ft²
5.0'26.0'5.0'FOP130.0 ft²17.0'7.0'
1
0
.
6
'
21.0'10.6'7.0'17.0'WDD 699.9 ft²
Extra Feature Occurrence 1
XFOB Code 110 - FIREPL. A.Abstract Code 1212 - SINGLE FAM.RES-
IMPROVEMTS
Percentage 100.0 Use Code 1000 - RESIDENTIAL
Neighborhood 1010 - OAK RIDGE I Building Number 1
SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT
XFOB Units 1
Total 1.00
Value Rate Rate Rate Rate
$3,520 3,520.00
Abstract Summary
Code Classification Actual Value Taxable
Value
Actual
Override
Taxable
Override
1112 SINGLE FAM.RES.-LAND $190,000 $13,590 NA NA
1212 SINGLE FAM.RES-IMPROVEMTS $662,490 $47,370 NA NA
Total $852,490 $60,960 NA NA
Property Record Card
Eagle County
A#: R031608 P#: 239127207005 As of: 04/25/2021 Page 3 of 3
ZAMORA EXCAVATING, INC.
P.O. Box 754 • Carbondale, CO 81623
Office: (970) 963-1399 • Cell: (970) 379-7171
May 15, 2025
Eagle County Environmental Health
551 Broadway
Eagle, Colorado 81631
Re: OWTS Inspection
554 Escalante
Eagle County, Colorado
On May 12, 2025 1 inspected the septic system located at 554 Escalante. During this inspection the
septic tank was pumped by All Valley Resource. The tank appeared to be in good condition.
I was able to locate the approximate area of the leach field. As Eagle County had no original design of
the leach field that was installed, I based the schematic on a 600sq' leach field which is the specification
recommended by Eagle County for this system. There appeared to be no adverse conditions in the leach
field. There was no visible ground water or odor detected.
Overall, I found the septic system to be in good working condition.
If you need further information, I can be reached at (970) 379-7171.
Thank you.
cam✓ ,f 2r °Y'!✓� !G
oseph B. Zamora
NAWT Certified Inspector
Certification #132631TC
ZAMORA EXCAVATING, INC.
A I
ig-4
P.O. Box 754 • Carbondale, CO 81623
Office: (970) 963-1399 • Cell: (970) 379-7171
May 15, 2025
Re: OWTS Inspection
554 Escalante
Eagle County, Colorado
Disclaimer: This inspection is intended as an evaluation of the present condition of the onsite
wastewater treatment system based upon what was observed and the Licensed Inspector's
expertise in onsite wastewater technology. The Inspector has not been retained to
warrant or guarantee the proper functioning of the system for any period of time in the
future. Because of the numerous factors which may affect the operation of an onsite
wastewater treatment system, as well as the inability of the Inspector to supervise or
monitor the use or maintenance of this system, this report shall not be construed as a
warranty by the Inspector that the system will function properly for any particular
prospective buyer. The Inspector disclaims any warranty, either expressed or implied,
arising from the inspection or this report. The evaluation does not ascertain the impact
the system is having on groundwater.
Please feel free to contact me at (970) 379-7171 should you have any questions.
Sincerely,
J6se. Zamora
NAWT Certified Inspector
Certification #132631TC
ZAMORA EXCAVATING, INC.
P.O. Box 754 • Carbondale, CO 81623
Office: (970) 963-1399 • Cell: (970) 379-7171
May 15, 2025
Eagle County Environmental Health
551 Broadway
Eagle, Colorado 81631
Re: OWTS Inspection
554 Escalante
Eagle County, Colorado
On May 12, 2025 1 inspected the septic system located at 554 Escalante. During this inspection the
septic tank was pumped by All Valley Resource. The tank appeared to be in good condition.
I was able to locate the approximate area of the leach field. As Eagle County had no original design of
the leach field that was installed, I based the schematic on a 600sq' leach field which is the specification
recommended by Eagle County for this system. There appeared to be no adverse conditions in the leach
field. There was no visible ground water or odor detected.
Overall, I found the septic system to be in good working condition.
If you need further information, I can be reached at (970) 379-7171.
Thank you.
cam✓ ,f 2r °Y'!✓� !G
oseph B. Zamora
NAWT Certified Inspector
Certification #132631TC
ZAMORA EXCAVATING, INC.
A I
ig-4
P.O. Box 754 • Carbondale, CO 81623
Office: (970) 963-1399 • Cell: (970) 379-7171
May 15, 2025
Re: OWTS Inspection
554 Escalante
Eagle County, Colorado
Disclaimer: This inspection is intended as an evaluation of the present condition of the onsite
wastewater treatment system based upon what was observed and the Licensed Inspector's
expertise in onsite wastewater technology. The Inspector has not been retained to
warrant or guarantee the proper functioning of the system for any period of time in the
future. Because of the numerous factors which may affect the operation of an onsite
wastewater treatment system, as well as the inability of the Inspector to supervise or
monitor the use or maintenance of this system, this report shall not be construed as a
warranty by the Inspector that the system will function properly for any particular
prospective buyer. The Inspector disclaims any warranty, either expressed or implied,
arising from the inspection or this report. The evaluation does not ascertain the impact
the system is having on groundwater.
Please feel free to contact me at (970) 379-7171 should you have any questions.
Sincerely,
J6se. Zamora
NAWT Certified Inspector
Certification #132631TC
;f<2z:-
M
N�.
5113125, 3:34 PM
Mail - Gerry Zamora - Outlook
htps:lloutiook_live.comlma ill0li nboxli dlAQMkADAwATN iZmYAZC00YThmLThjYwA2LTAwAiOwMAoARgAAA°1o2BTDYvl8RFxGnMF7wCzDJ ygHAAgYM... 1 f 1
� 5
fl
5 v,� And
f
x r y
r � }. { � � �.,_ , -0 " to - �. - .•
9s-NO—
Now'Omsk- -. e. �--
�y. .t`.'1 f; A.
Ma
Id ♦` I� 1. + #.
�f �... NOW
J ` ' v,. - 1 _? �' , r� 't t • x41:� '!'�-. w i y} /'1 �`,33 r ` s+..
�+ .� fir+ `�i.. lad' .%�"•°'�` t,,�s r.+�y�r '��,�,�� lRAM
F ��`\(��{-�1�� ��w .PL � f �� F�"•iy7 \^S1 _: '�. %�i F mod,. �J. .^.J � _ y�c�
Ait
is n t
� aL :J
"� way Y =7 f1•� +�F' - � s'^ � 1t ,, 4�y7� ��,�4 ,• 6� "':'� � (.
sale
+x . }` 4 i � _ 1 ,dam. r• S
Ito