Permit
Permit No. OWTS-020827-2021
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 3/31/2021 Expires: 7/29/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
95 BLUE CREEK TRL, EL JEBEL AREA,239127105003
Owner Information Address
Brad Frisselle Phone:
Cell: (808) 283-2184
Email: bradterrye@hotmail.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
CBO Septic Consulting, Carla Ostberg (970) 309-0525 carla.osteberg@gmail.com
Contractor License Number Phone Email
Permitted Construction / Details:
Install the new system exactly as depicted in the CBO Septic Consulting design dated November 29th, 2020, signed
and stamped on December 2nd by Richard Petz P.E. This design will replace that submitted on October 15th, 2017.
The new system will be sized to accommodate the maximum daily flows for a 4 bedroom residence.
Two 8 foot deep test pits immediately adjacent to the STA must be excavated prior to installation to verify the soil
types present. Eagle County Environmental Health must be contacted to verify this at the time of excavation.
This OWTS consists of one sewer line from the residence. An Infiltrator 1,500 gallon two-compartment poly septic
tank with an effluent filter on the outlet tee followed by an Infiltrator 500 gallon pump chamber shall be used. An
Orenco ProPak PF3005 pump shall be used. The floats will be set to dose at 70 gallons per dose. An ADV will be
placed at the high point of the system and will be accessible at grade. The STA consists of three gravelless chamber
beds each with 2 rows of 10 Quick 4 Low Profile Infiltrator chambers for a total of 60.
A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County
(EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor
without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503,
C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Sell
Date
March 31, 2021
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Wednesday, March 31, 2021 1
***************************************************************************
APPLICATION FOR ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS) PERMIT
INCOMPLETE APPLICATIONS MAY NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEE SCHEDULE
APPLICATION FEE FOR NEW OWTS OR MAJOR REPAIRS $800.00 MINOR REPAIR FEE $400.00
Fee includes the design review, permitting and maintenance of OWTS records
Make all checks payable to: Eagle County Treasurer
Property Owner: _______________________________________Phone: ________________________
Owner Mailing Address: ________________________________ email: _________________________
Professional Engineer: __________________________________ Phone: ________________________
Applicant / Contact Person: ______________________________Phone: ________________________
Licensed Systems Contractor Name / Company: ___________________________________________
Contractor Mailing Address: _________________________________ Contractor License #:_______
Contractor Phone Number: ________________________ email: ______________________________
OWTS Permit Application is for: ____ New Installation ____ Alteration ____ Repair
Tax Parcel Number: _________________________________ Lot Size: ________________________
Assessor’s Link: www.eaglecounty.us/patie/
Physical Address: _____________________________________________________________________
Legal Description: ____________________________________________________________________
Building Type: _____ Residential / Single Family
_____ Residential / Multi Family
_____ Commercial / Industrial
Number of Bedrooms: ______
Number of Bedrooms: ______
Type of Use: _______________
*As of 06/27/2014, all systems require design by a Registered Professional Engineer.
Type of Water Supply: ____ Private Well ____ Spring ____ Surface ____ Public
If Public, Name of Supplier: ____________________________________________________________
Applicant Signature: ______________________________________Date:_______________________
****************************************************************************
Office Use Only: OWTS PERMIT # __________________ BUILDING PERMIT # ____________________
Amount Paid: ___________ Receipt #: ___________ Check #: ___________ Date: ______________
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.eaglecounty.us
P.O. Box 179
500 Broadway
Eagle, CO 81631
environment@eaglecounty.us
Brad & Terrye Frisselle 808 283 2184
123 Larkspur Lane, Aspen CO 81611 bradterrye@hotmail.com
Carla Ostberg, All Service Septic 970 309 5259
Olafur Johannsson 970 544 3377
T.B.D.
4
2391-271-05-003 4.457 acres
95 Blue Creek Trail
Lot 12 first filing Mountain Meadow Ranch
4
4
3
Olafur Johannsson
Digitally signed by Olafur Johannsson
DN: cn=Olafur Johannsson, o=Johannsson
Architects Inc., ou, email=oli@j-architects.net, c=US
Date: 2021.03.22 16:40:20 -06'00'
03/21/21
Inspection Result
Eagle County, Colorado
P.O. Box 179 500 Broadway Eagle, CO
Phone: (970) 328-8730 Fax: (970) 328-7185
IVR Phone: 1-866-701-3307
Inspection Number: INSP-518464-2022 Permit Number: OWTS-020827-2021
Inspection Date: 11/08/2022
Inspector: Lewandowski, Claire
Permit Type: OWTS Permit
Inspection Type: OWTS Final Inspection
Work Classification: NewOwner:Brad Frisselle
Job Address:95 BLUE CREEK TRL IVR Pin Number:192495
EL JEBEL AREA, CO Project:<NONE>
Parcel Number:239127105003
Contractor:Phone: / Cell:
Inspection Status: Approved
Inspection Notes
Inspector Comments
Added Item: Septic Tank
A 1500-gallon, two-compartment poly Infiltrator septic tank with an Orenco Biotube Effluent Filter on the
outlet tee followed by a 500-gallon Infiltrator pump chamber with an Orenco ProPak and PF3005 pump
were installed.
Added Item: Record Drawing
Received 6/14/2023 from CBO Inc.
Added Item: Record Photos
Received 6/14/2023 from CBO Inc.
Added Item: Site and Soil
Received 3/22/2021 from CBO Inc. Approved changes necessary for type R-1 soils observed in the
field upon inspection. Two feet of secondary sand was installed. under distribution laterals and
chambers were replaced with geomat distribution. Observed in compliance with regulations.
Added Item: Final Certification Letter
Received 6/14/2023 from CBO Inc.
Added Item: General Plan
Received 3/22/2021 from CBO Inc.
Added Item: Soil Treatment Area (STA)
Wednesday, June 14, 2023
For more information visit: http://www.eaglecounty.us
Page 1 of 2
Effluent is pressure dosed through 1.5-inch diameter distribution lines to three 7’ x 32’ beds. A
minimum of 2-feet of sand filter material was installed under GeoMat sheets.
Laterals were 1.5-inches in diameter with 5/32-inch diameter orifices facing down, spaced 2-feet on
center, installed on the GeoMat with the filter fabric over the laterals. Two 39” wide GeoMat were placed
on the 7-foot wide bed.
Added Item: Identification of Systems Contractor
Skyline Excavation was the licensed installer. License was obtained after installation.
Wednesday, June 14, 2023
For more information visit: http://www.eaglecounty.us
Page 2 of 2
CBO Inc.
129 Cains Lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
June 4, 2023 Project No. C1308
Brad Frisselle
123 Larkspur Lane
Aspen, CO 81611
Onsite Wastewater Treatment System (OWTS) Installation Observations
95 Blue Creek Trail
Eagle County, Colorado
Eagle County Permit OWTS-020827-2021
Brad,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on October 12 and
25, 2022 for the subject property. Skyline Excavating installed the system.
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD was used.
The system installation included a 1500-gallon, two-compartment poly Infiltrator® septic tank with an
Orenco® Biotube Effluent Filter on the outlet tee followed by a 500-gallon Infiltrator® pump chamber with
an Orenco® ProPak and PF3005 pump. The effluent filter in the pump chamber must be cleaned
annually, or as needed. The floats were set to dose approximately 70 gallons each pump cycle. The
control panel is located within line of sight of the septic tank, mounted on the exterior of the residence.
Valley Precast out of Buena Vista performed start up on the pumping system.
A 1.5-inch diameter Schedule 40 pump line was installed from the pump to an Orenco® automatic
distributing valve (ADV), model 6403. The ADV was placed at a high point in the system in an insulated riser
with access from grade.
A change was made to the soil treatment area (STA) after it was discovered that soils in the proposed STA
were classified as R-1.
Effluent is pressure dosed through 1.5-inch diameter distribution lines to three 7’ x 32’ beds. A minimum of
2-feet of sand filter material was installed under GeoMat™ sheets.
Laterals were 1.5-inches in diameter with 5/32-inch diameter orifices facing down, spaced 2-feet on center,
installed on the GeoMat™ with the filter fabric over the laterals. Two 39” wide GeoMat™ were placed on the
7-foot wide bed.
Each 1.5-inch diameter lateral ends in a sweeping ell facing up with a ball valve for flushing. Valves were
placed in a 10-inch sprinkler box for access. Inspection ports were placed in each corner of both beds.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS:
Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent on the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS
Septic tanks set COLORADO R E GIST
E
R
E
DTHOMAS A . C
RO
N
KPRO
F
E
SSI O N A L ENGINEER28322
View of septic tanks looking toward house
Septic tank
Clean out
Sewer line from house to tank
Inlet tee Effluent filter
Pump chamber Pump line from pump chamber to ADV
Geomat on sand
GeoMat beds
Pump chamber and ADV
ADV
Ready to install Orifice Shields
Control panel Inlet tee
Pumping system
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-020827-2021
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 3/31/2021 Expires: 7/29/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
95 BLUE CREEK TRL, EL JEBEL AREA,239127105003
Owner Information Address
Brad Frisselle Phone:
Cell: (808) 283-2184
Email: bradterrye@hotmail.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
CBO Septic Consulting, Carla Ostberg (970) 309-0525 carla.osteberg@gmail.com
Contractor License Number Phone Email
Permitted Construction / Details:
Install the new system exactly as depicted in the CBO Septic Consulting design dated November 29th, 2020, signed
and stamped on December 2nd by Richard Petz P.E. This design will replace that submitted on October 15th, 2017.
The new system will be sized to accommodate the maximum daily flows for a 4 bedroom residence.
Two 8 foot deep test pits immediately adjacent to the STA must be excavated prior to installation to verify the soil
types present. Eagle County Environmental Health must be contacted to verify this at the time of excavation.
This OWTS consists of one sewer line from the residence. An Infiltrator 1,500 gallon two-compartment poly septic
tank with an effluent filter on the outlet tee followed by an Infiltrator 500 gallon pump chamber shall be used. An
Orenco ProPak PF3005 pump shall be used. The floats will be set to dose at 70 gallons per dose. An ADV will be
placed at the high point of the system and will be accessible at grade. The STA consists of three gravelless chamber
beds each with 2 rows of 10 Quick 4 Low Profile Infiltrator chambers for a total of 60.
A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County
(EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor
without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503,
C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Sell
Date
March 31, 2021
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Wednesday, March 31, 2021 1
832‐R‐13‐002
November 29, 2020 Project No. C1308
Brad Frisselle
123 Larkspur Lane
Aspen, CO 81611
c/o Oli Johannsson
oli@j-archictes.net
Subsurface Investigation and Onsite Wastewater Treatment System Design
4-Bedroom Residence
95 Blue Creek Trail
Eagle County, Colorado
Brad,
ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater
treatment system (OWTS) design for the subject residence. The 4.46-acre property is located outside of
Basalt, in an area where OWTSs and wells are necessary. The site plan has been updated since our
original design dated October 15, 2017, in addition to changes in the regulation that necessitated the
design to be updated. Plans dated October 15, 2017 should be discarded and replaced with these dated
November 29, 2020.
Legal Description: Subdivision: MOUNTAIN MEADOW RANCH FIL 1 Lot: 12
BK-0277 PG-0410 MAP 10-30-78
Parcel ID: 2391-271-05-003
SITE CONDITIONS
The property is currently undeveloped and a 4-bedroom, single-family residence is proposed.
A private well will serve the residence potable water. The well is located greater than 50-feet from the
proposed septic tank and greater than 100-feet from the proposed soil treatment area (STA).
The proposed STA slopes to the south at approximately 20%. The area is vegetated with native grasses
and sage.
Table 1 describes the minimum required setback of OWTS components to physical features on the
property compared to approximate, proposed setback distances.
Table 1
OWTS Components and
Physical Features
Minimum Required Setback Approximate Proposed Setback
House to Septic Tank 5’ 40’
Septic Tank to Well 50’ 170’
STA to House 20’ 42’
STA to Well 100’ 153’
Page 2
SUBSURFACE
The subsurface was investigated on July 28, 2017 by digging two soil profile test pit excavations (Test Pits).
Visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.1 CTL Thompson
was also present to view and sample soils for the foundation. CTL Thompson’s report, Project No.
GS06158.000-120 dated September 6, 2017, is enclosed.
STA location will be in the area of Test Pit #2 and sizing is based on Soil Type 2. A long term
acceptance rate (LTAR) of 0.6 gallons per square foot, will be used to design the OWTS, in
accordance with Table 10-1 Soil Type 2 presented in the Eagle County On-Site Wastewater
Treatment System Regulations, adopted May 13, 2014.
Test Pits observed July 28, 2017
Test Pit #1
Test Pit #1 very rocky with backhoe refusal at approximately 4 to 5 feet below grade (near foundation)
Test Pit #2
Test Pit #2 less rocky, digging successful to approximately 6-feet below grade before refusal
1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
Page 3
Sieved sample
DESIGN SPECIFICATIONS
Design Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 75 GPD (4th bedroom) = 525 GPD
LTAR = 0.6 GPD/SF
525 GPD / 0.6 GPD/SF x 1.0 (pressure dosed beds) x 0.7 (chambers) = 613 SF
For the purposes of this OWTS design, Benchmark Elevation as finished floor of the residence has been
established as 100’ (7283’ 4”). CBO Inc. should be notified of any discrepancies or problems with grade
elevations of proposed components during installation of the OWTS.
OWTS Component Minimum Elevation
Primary Tank Inlet Invert Approx. horizontal distance 40’ / min. 2% fall / min.
10” fall to septic tank
Automatic Distributing Valves (ADVs) Approx. horizontal distance 19’ / min. 1% rise for
drain back / min. 2.375” rise
Infiltrative Area (to highest trench) Approx. horizontal distance 22’ / min. 1% fall / min.
2.75” fall
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD will be used.
The system installation will include a 1500-gallon, two-compartment poly Infiltrator® septic tank with an
Orenco® Biotube Effluent Filter on the outlet tee followed by a 500-gallon Infiltrator® pump chamber with
an Orenco® ProPak and PF3005 pump. The floats must be set to dose approximately 70 gallons each
pump cycle. The control panel must be located within line of sight of the septic tank. We
recommend Valley Precast out of Buena Vista perform start up on the pumping system.
Pump Table
Dose Range Max = 133 gal. (525 GPD x 25%
+ 2 gal drain back)
Min. 52 gal. (13 gal x 4) + 2 gal
drain back
Dose Setting 70 gallons/dose 2 gallons drain back (20’ / 1.5”
diameter pump line)
Float Separation 500-gallon pump chamber 5.5” on/off float separation
Pump Criteria 18.9 gallons per minute (GPM) 16 feet total dynamic head (TDH)
PVC risers must be installed on the tanks to bring access to grade. Enclosed specifications detail the
riser, lids, and tank adapter. Handle extensions on both the effluent filter and float tree must be installed
if the riser height exceeds 1-foot.
Page 4
A 1.5-inch diameter Schedule 40 pump line must be installed from the pump to an Orenco® automatic
distributing valve (ADV), model 6403. This pump line must have a minimum 1% grade for proper drain back
into the tank after each pump cycle. The ADV must be placed at a high point in the system and be placed in
an insulated riser with access from grade. Screened rock must be placed below the ADV to support the
ADV and to assure the clear pipes existing the ADV remain visible for future inspection and maintenance.
Effluent will be pressure dosed through 1.5-inch diameter pipes to three gravelless chamber beds, each
with 2 rows of 10 ‘Quick 4’ Low Profile Infiltrator® chambers, for a total of 60 chambers and 720 square
feet of infiltrative area. It should be noted that we kept sizing based of the STA based on 600 GPD rather
than 525 GPD. There must be at least 6-feet of undisturbed soil between each bed. Chambers may
not be placed more than 2-feet below native grade. Mounding over chambers may be necessary
to achieve a minimum of 1-foot of cover over chambers.
A level 1.5-inch diameter manifold will connect laterals in each bed. Effluent will be pressure dosed to
1.5-inch diameter laterals, which must be hung with zip ties from the underside of the chambers. Laterals
will have 5/32-inch diameter orifices facing up, with the exception of the first and last holes facing down
for drainage. Orenco® Orifice Shields may be placed under each downward-facing orifice. The orifices
must be placed 3-feet on center. Each lateral must end in a 90 degree ell facing up with a ball valve for
flushing. Valves may be placed in a valve box, accessible from grade, for access. Inspection ports must
be placed at the beginning and end of each trench. Ports may be cut to grade and covered with a valve
box for access.
The component manufacturers are typical of applications used by contractors and engineers in this area.
Alternatives may be considered or recommended by contacting our office. Construction must be
according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided
by Eagle County Environmental Health Department, and this design.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over
the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Livestock should not graze on the STA. Plumbing fixtures should be
checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or
leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
Page 5
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high
water conditions and shall be connected to a control breaker separate from the high water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be
performed before backfill, after placement of OWTS components. Septic tanks, distribution devices,
pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic,
LLC should be notified 48 hours in advance to observe the installation.
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be
according to the county regulations. Requirements not specified in this report must follow applicable
county regulations. The contractor should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working. Licensing of Systems Contractors
may be required by county regulation.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By:
Carla Ostberg, MPH, REHS
12/2/2020
Pump Selection for a Pressurized System - Single Family Residence Project
Frisselle Residence / 95 Blue Creek Trail
Parameters
Discharge Assembly Size
Transport Length Before Valve
Transport Pipe Class
Transport Line Size
Distributing Valve Model
Transport Length After Valve
Transport Pipe Class
Transport Pipe Size
Max Elevation Lift
Manifold Length
Manifold Pipe Class
Manifold Pipe Size
Number of Laterals per Cell
Lateral Length
Lateral Pipe Class
Lateral Pipe Size
Orifice Size
Orifice Spacing
Residual Head
Flow Meter
'Add-on' Friction Losses
1.25
20
40
1.50
6403
43
40
1.50
3
3
40
1.50
6
40
40
1.50
5/32
3
5
None
0
inches
feet
inches
feet
inches
feet
feet
inches
feet
inches
inches
feet
feet
inches
feet
Calculations
Minimum Flow Rate per Orifice
Number of Orifices per Zone
Total Flow Rate per Zone
Number of Laterals per Zone
% Flow Differential 1st/Last Orifice
Transport Velocity Before Valve
Transport Velocity After Valve
0.68
28
18.9
2
0.8
3.0
3.0
gpm
gpm
%
fps
fps
Frictional Head Losses
Loss through Discharge
Loss in Transport Before Valve
Loss through Valve
Loss in Transport after Valve
Loss in Manifold
Loss in Laterals
Loss through Flowmeter
'Add-on' Friction Losses
2.5
0.4
3.9
0.9
0.0
0.1
0.0
0.0
feet
feet
feet
feet
feet
feet
feet
feet
Pipe Volumes
Vol of Transport Line Before Valve
Vol of Transport Line After Valve
Vol of Manifold
Vol of Laterals per Zone
Total Vol Before Valve
Total Vol After Valve
2.1
4.5
0.3
8.5
2.1
13.3
gals
gals
gals
gals
gals
gals
Minimum Pump Requirements
Design Flow Rate
Total Dynamic Head
18.9
16.0
gpm
feet
0 5 10 15 20 25 30 35 40
0
50
100
150
200
250
300
Net Discharge (gpm)
PumpData
PF3005 High Head Effluent Pump
30 GPM, 1/2HP
115/230V 1Ø 60Hz, 200V 3Ø 60Hz
PF3007 High Head Effluent Pump
30 GPM, 3/4HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF3010 High Head Effluent Pump
30 GPM, 1HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF3015 High Head Effluent Pump
30 GPM, 1-1/2HP
230V 1Ø 60Hz, 200/230/460V 3Ø 60Hz
Legend
System Curve:
Pump Curve:
Pump Optimal Range:
Operating Point:
Design Point:
Item#
SEK- Orenco® Flushing Assemblies
Flushing Assemblies
Orenco® flushing assemblies provide easy
access for lateral maintenance. Flushing
assembly kits include a PVC sweep with ball
valve and a polyethylene valve box enclosure.
Orenco® flushing assemblies are available in the
following sizes:
• 1” diameter
• 1.25” diameter
• 1.5” diameter
• 2" diameter
Valve Boxes
Orenco® valve boxes are used to provide access
to flushing assemblies. Constructed of
polyethylene.
Valve Box, 7-in. diameter round enclosure
Note: Kits include VB7 valve box enclosure.
(719) 395-6764
Fax: (719) 395-3727
28005 County Road 317
P.O. Box 925
Buena Vista, CO 81211
Water &
Wastewater
• Systems
• Products
• Service Website: http://valleyprecast.com/
Email: frontdesk@valleyprecast.com
• Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
• Installs in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
• Easy to clean by
simply hosing off
whenever the tank
needs pumping
• Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
• Corrosion-proof
construction, to
ensure long life
• Lifetime warranty
Residential Biotube® Effluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a lifetime warranty. They prevent large solids from leaving
the tank, dramatically improving wastewater quality and extending the life
of residential drainfields.
Standard Features & Benefits
• Alarm available, to
signal the need for
cleaning
• Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
• Custom and
commercial sizes
available
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes’ entire
surface for filtering.
Particles larger than
the Biotube’s mesh
are prevented from
leaving the tank.
Optional
Features &
Benefits
Biotube
Filtering
Process
8-in. (200-mm)
Base Inlet Filter
4-in. (100-mm)
Insert Filter
4-in. (100-mm) Biotube Jr.
(4-in. Biotube cartridge avail-
able separately as Insert Filter)
Orenco’s superior effluent filters resist clogging better than all other brands. Our stan-
dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term
protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at
half the size of our standard model, has more filtering capacity than the full-sized filters
sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter
is ideal. And for low-profile tanks, there’s the Base Inlet Filter.
* Covered by patent numbers 5,492,635 and 4,439,323
4-in. (100-mm) Biotube Effluent Filter
APS-FT-1
Rev. 3.4 © 11/10
Orenco Systems®, Inc.
To Order
Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on
“Distributor Locator.”
Nomenclatures
Riser
wall
Tank wall
Filter housing
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube® filter cartridge
Solid base
4-in. Biotube
Effluent Filter
4-in. Biotube Jr.
4-in. Biotube Filter (standard)
4-in. Biotube Jr. (includes cartridge and housing)
Distributed By:
8-in. Biotube Filter (base inlet model)
4-in. Biotube Filter Insert (cartridge only)
Junior series
FT J0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Blank = 1/8" filtration
P = 1/16" filtration
Insert
FT i0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
-
For customized options (e.g., NC
indicates North Carolina regions)
-
Blank = 1/8" filtration
P = 1/16" filtration
FT 04
Biotube effluent filter series
Filter diameter (inches)
Housing height: 36" and 44" are standard
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Cartridge height: 28" and 36" are standard
-
Blank = 1/8" filtration
P = 1/16" filtration
W = fits Type 3034 outlet pipe
S = fits Schedule 40 outlet pipe
FT 2208 14 B
Biotube effluent filter series
Housing height: 22" standard
Cartridge height: 14" standard
Options:
A = float bracket
FS = 2" outlet orifice
FSO = 2" outlet orifice and overflow plate*
Base inlet model
-
Blank = 1/8" filtration
P = 1/16" filtration
Filter diameter (inches)
08 = 8"
* Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT
• PVC risers and
fiberglass access
lids come in various
diameters.
• PVC risers available
in standard 6-in.
(152-mm) incre-
ments.
• Custom risers can be
cut in 1-3 in. (25-76
mm) increments,
depending on riser
diameter.
• PVC risers can be
cast right into a con-
crete tank.
• PVC risers can be
installed onto a
concrete tank with a
bolt-down kit
• Cast-in or bolt-down
riser-tank adapters
are available.
• PVC risers and
fiberglass riser-tank
adapters can be
easily bonded to
fiberglass tanks with
a structural adhesive.
• Grade rings allow
installers to stack
extensions onto
PVC risers in the
field.
• Lids are easy to
install with stainless
steel, tamper-resis-
tant bolts (wrench
included) that help
prevent accidental
entry.
• Lids are lightweight,
watertight, non-skid,
and non-corroding.
• Lid insulation and
carbon filter vents
are available options.
• Lids can withstand
2500-lb wheel loads
(1100 kg), stronger
than any other lid on
the market.
• While not designed
for vehicular traffic,
lids have a breaking
point of 8000 lbs
(3600 kg).
• Lids are flat to allow
placement of back-
yard furnishings. No
unsightly domes, no
tripping.
• Standard lids are an
attractive green or
brown and blend in
with landscaping.
• Custom lid colors and
custom lid imprint-
ing are available on
quantity orders.
• Additional accesso-
ries are available for
PVC risers and lids,
including adhesive,
pipe grommets, cord
grips, splice boxes,
pipe cutting and drill-
ing tools, insulation,
vents, and fiberglass
brackets.
PVC Access Risers, Lids, & Accessories
Our PVC risers, fiberglass access lids, and other tank accessories allow access
to tanks without excavation. They’re adaptable to virtually any tank, both new and
existing. Lids and accessories fit most types of ribbed PVC pipe, including Ultra-Rib,
Ultra-Corr, KOR FLO, and Perma-Loc. Preassembled PVC risers and stock pipe lengths
can be purchased from Orenco. Or stock lengths can be purchased locally and cut as
needed. All components are designed to work well together.
Standard Features & Benefits
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA
800-348-9843 • 541-459-4449 • www.orenco.com
APS-RLA-1
Rev. 4.6 © 11/13
Page 1
Product SheetOrenco®
Orenco Systems®, Incorporated
Orenco®To Order
Call your nearest Orenco Systems®, Inc. Distributor. For nearest Distributor, call
Orenco at 800-348-9843, or visit www.orenco.com and click on “Distributor Locator.”
In addition to standard green and brown
lids, Orenco offers Landscape Lids in
grass, bark, and river rock patterns.
Landscape Lids are available in 18-,
21-, 24-, and 30-in. (460-, 535-, 610-,
and 760-mm) sizes. Custom imprinting
is available on quantity orders of
24- and 30-in. diameter lids (610-
and 760-mm).
Orenco’s PVC risers, fiberglass
access lids, and other accessories
are superior in quality, watertight,
non-corroding, and lightweight yet
strong.
Distributed By:
Model Code for Ordering (PS_Subheads #2)Biotube Pump Vault ComponentsPVC Access Risers, Lids & AccessoriesOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA
800-348-9843 • 541-459-4449 • www.orenco.com
APS-RLA-1
Rev. 4.6 © 11/13
Page 2
PVC Risers
Available in the following diameters: 12, 18,
24, and 30 in. (305, 460, 610, and 760 mm).
Can be installed with adapters or cast into
concrete tank. Lighter-duty PIP risers avail-
able in 8- and 15-in. diameters (205 and 380
mm).
Fiberglass Lids
Standard lids (green and brown ) are available
in the following diameters: 12, 18, 21, 24, 30,
36, and 48 in. (305, 460, 610, 760, 915,
1220 mm). Lighter-duty lids available in 8-,
12-, and 15-in. diameters (200, 305, 380
mm). Landscape Lids in grass, bark, and river
rock patterns are available in 18-, 21-, 24-,
and 30-in. (460-, 535-, 610- and 760-mm)
diameters. Custom imprinting available on
24-in. and 30-in. lids (610 and 760 mm)
Bolt-Down Kits
For fastening tank adapter to tank. Kit
includes stainless steel anchor bolts and
butyl sealant.
Tank Adapters
Fiberglass
RRFTA adapter
fits square
openings.
Available in 24- and 30-in. diameters (610
and 760 mm). Can be cast into or bolted to
concrete tank.
Riser Extension Adapters
(Grade Rings)
These easy-to-install adapters allow height
adjustment of risers in the field.
Lid Fasteners
Self-tapping stainless steel bolt can be used
on risers with and without bolt catches. Ask
us about hex-drive bits.
Cutting Jigs and Tools
For cutting Perma-Loc, Ultra-Rib, KOR FLO,
and Ultra-Corr pipe in the field and preparing
pipe for grommets/lid attachment.
Structural Adhesives
Adhesives are available for a variety of prod-
ucts that need bonding or sealing: PVC, ABS,
fiberglass, concrete, and rubber.
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 1 of 4
Biotube® ProPak Pump Package™
Technical Data SheetOrenco®
60-Hz Series Pump Packages General
Orenco’s Biotube® ProPak™ is a complete, integrated pump package for
filtering and pumping effluent from septic tanks. And its patented pump
vault technology eliminates the need for separate dosing tanks.
This document provides detailed information on the ProPak pump vault
and filter, 4-in. (100-mm) 60-Hz turbine effluent pump, and control panel.
For more information on other ProPak components, see the following
Orenco technical documents:
• Float Switch Assemblies (NSU-MF-MF-1)
• Discharge Assemblies (NTD-HV-HV-1)
• Splice Boxes (NTD-SB-SB-1)
• External Splice Box (NTD-SB-SB-1)
Applications
The Biotube ProPak is designed to filter and pump effluent to either
gravity or pressurized discharge points. It is intended for use in a septic
tank (one- or two-compartment) and can also be used in a pump tank.
The Biotube ProPak is designed to allow the effluent filter to be removed
for cleaning without the need to remove the pump vault or pump, simpli-
fying servicing.
Complete packages are available for on-demand or timed dosing sys-
tems with flow rates of 20, 30, and 50-gpm (1.3, 1.9, and 3.2 L/sec),
as well as with 50 Hz and 60 Hz power supplies.
Standard Models
BPP20DD, BPP20DD-SX, BPP30TDA, BPP30TDD-SX, BBPP50TDA,
BPP50TDD-SX
Product Code Diagram
Biotube® ProPak™ pump package components.
4-in. (100-mm)
turbine effluent pump
Pump motor
Pump
liquid end
Pump vault
Support pipe
Discharge
assembly
Float collar
Float stem
Floats
Float
bracket
Biotube® filter
cartridge
Vault inlet holes
External splice box
(Optional; internal splice
box comes standard.)
Riser lid
(not included)
Riser (not
included)
Control panel
BPP
Pump flow rate, nominal:
20 = 20 gpm (1.3 L/sec)
30 = 30 gpm (1.9 L/sec)
50 = 50 gpm (3.2 L/sec)
Control panel application:
DD = demand-dosing
TDA = timed-dosing, analog timer
TDD = timed dosing, digital timer, elapsed time
meter & counters
Standard options:
Blank = 57-in. (1448-mm) vault height, internal
splice box, standard discharge assembly
68 = 68-in. (1727-mm) vault height
SX = external splice box
CW = cold weather discharge assembly
DB = drainback discharge assembly
Q = cam lock
MFV = non-mercury float
-
Biotube® ProPak™ pump vault
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 2 of 4
ProPak™ Pump Vault
Materials of Construction
Vault body Polyethylene
Support pipes PVC
Dimensions, in. (mm)
A - Overall vault height 57 (1448) or 68 (1727)
B - Vault diameter 17.3 (439)
C - Inlet hole height 19 (475)
D - Inlet hole diameter (eight holes total) 2 (50)
E - Vault top to support pipe bracket base 3 (76)
F - Vault bottom to filter cartridge base 4 (102)
ProPak™ pump vault (shown with Biotube filter and effluent pump)
Biotube® Filter Cartridge
Materials of Construction
Filter tubes Polyethylene
Cartridge end plates Polyurethane
Handle assembly PVC
Dimensions, in. (mm)
A - Cartridge height 18 (457)
B - Cartridge width 12 (305)
Performance
Biotube® mesh opening 0.125 in. (3 mm)*
Total filter flow area 4.4 ft2 (0.4 m2)
Total filter surface area 14.5 ft2 (1.35 m2)
Maximum flow rate 140 gpm (8.8 L/sec)
*0.062-in. (1.6-mm) filter mesh available
Biotube® filter cartridge (shown with float switch assembly)
AA
D
E
B B
C
E
Technical Data Sheet Orenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 3 of 4
Pump Curves
Pump curves, such as those shown here, can help you determine
the best pump for your system. Pump curves show the relationship
between flow (gpm or L/sec) and pressure (TDH), providing a graphical
representation of a pump’s performance range. Pumps perform best
at their nominal flow rate, measured in gpm or L/sec.
4-in. (100-mm) Turbine Effluent Pumps
Orenco’s 4-in. (100 mm) Turbine Effluent Pumps are constructed of
lightweight, corrosion-resistant stainless steel and engineered plastics;
all are field-serviceable and repairable with common tools. All 60-Hz
PF Series models are CSA certified to the U.S. and Canadian safety
standards for effluent pumps, and meet UL requirements.
Power cords for Orenco’s 4-in. (100-mm) turbine effluent pumps are
Type SOOW 600-V motor cable (suitable for Class 1, Division 1 and 2
applications).
Materials of Construction
Discharge: Stainless steel or glass-filled polypropylene
Discharge bearing: Engineered thermoplastic (PEEK)
Diffusers: Glass-filled PPO
Impellers: Acetal (20-, 30-gmp), Noryl (50-gpm)
Intake screens: Polypropylene
Suction connection: Stainless steel
Drive shaft: 300 series stainless steel
Coupling: Sintered 300 series stainless steel
Shell: 300 series stainless steel
Lubricant: Deionized water and propylene glycol
Specifications
Nom. flow, Length Weight Discharge Impellers
gpm (L/sec) in. (mm) lb (kg) in., nominal 1
20 (1.3) 22.5 (572) 26 (11) 1.25 4
30 (1.9) 21.3 (541) 25 (11) 1.25 3
50 (3.2) 20.3 (516) 27 (12) 2.00 2
Performance
Nom. flow, hp (kW) Design Rated Min liquid
gpm (L/sec) flow amps cycles/day level, in. (mm) 2
20 (1.3) 0.5 (0.37) 12.3 300 18 (457)
30 (1.9) 0.5 (0.37) 11.8 300 20 (508)
50 (3.2) 0.5 (0.37) 12.1 300 24 (610)
1 Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® discharge
hose and valve assemblies. Consult your Orenco Distributor about fittings to connect discharge
assemblies to metric-sized piping.
2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® ProPak™ Pump
Vault.
10 20 30 40 6050 70
0.63 1.26 1.89 2.52 3.793.15 4.42
140
120
100
80
60
40
20
Flow in gallons per minute (gpm)
Flow in liters per second (L/sec)Total dynamic head (TDH) in feetTotal dynamic head (TDH) in metersPF 500511
43
37
30
24
18
12
6
PF 200511
PF 300511
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 4 of 4
AUTO
OFF
MAN
NN1
Control Panel (Demand Dose)
Orenco’s ProPak™ demand dose control panels are specifically engineered
for the ProPak pump package and are ideal for applications such as
demand dosing from a septic tank into a conventional gravity drainfield.
Materials of Construction
Enclosure UV-resistant fiberglass, UL Type 4X
Hinges Stainless steel
Dimensions, in. (mm)
A - Height 11.5 (290)
B - Width 9.5 (240)
C - Depth 5.4 (135)
Specifications
Panel ratings 120 V, 3/4 hp (0.56 kW), 14 A, single phase, 60 Hz
1. Motor-start contactor 16 FLA, 1 hp (0.75 kW), 60 Hz; 2.5 million cycles
at FLA (10 million at 50% of FLA)
2. Circuit 120 V, 10 A, OFF/ON switch, Single pole breakers
3. Toggle switch Single-pole, double-throw HOA switch, 20 A
4. Audio alarm 95 dB at 24 in. (600 mm), warble-tone sound, UL
Type 4X
5. Audio alarm 120 V, automatic reset, DIN rail mount silence
relay
6. Visual alarm 7/8-in. (22-mm) diameter red lens, “Push-to-silence,”
120 V LED, UL Type 4X
Control Panel (Timed Dose)
Orenco’s ProPak timed dose control panels are specifically engineered for
the ProPak pump package and are ideal for applications such as timed
dosing from a septic tank into a pressurized drainfield or mound. Analog or
digital timers are available.
Materials of Construction
Enclosure UV-resistant fiberglass, UL Type 4X
Hinges Stainless steel
Dimensions, in. (mm)
A - Height 11.5 (290)
B - Width 9.5 (240)
C - Depth 5.4 (135)
Specifications
Panel ratings 120 V, 3/4 hp (0.56 kW), 14 A, single phase, 60 Hz
Dual-mode Programmable for timed- or demand-dosing
(digital timed-dosing panels only)
1a. Analog timer 120 V, repeat cycle from 0.05 seconds to 30
(not shown) hours. Separate variable controls for OFF and
ON time periods
1b. Digital timer 120-V programmable logic unit with built-in LCD
(shown below) screen and programming keys. Provides control
functions and timing for panel operation
2. Motor-start contactor 16 FLA, 1 hp (0.75 kW), 60 Hz; 2.5 million cycles
at FLA (10 million at 50% of FLA)
3. Circuit breakers 120 V, 10 A, OFF/ON switch. Single pole 120 V
4. Toggle Switch Single-pole, double-throw HOA switch, 20 A
5. Audio alarm 95 dB at 24 in. (600 mm), warble-tone sound, UL
Type 4X
6. Visual alarm 7/8-in. (22-mm) diameter red lens, “Push-to-silence”,
120 V LED, UL Type 4X
Control panel, demand-dose Control panel, timed-dose (digital timer model shown)
1b
2
3
4
56
1
2
3
4
5
6
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 1 of 6
PF Series 4-inch (100-mm) Submersible Effluent Pumps
Technical Data SheetOrenco®
Applications
Our 4-inch (100-mm) Submersible Effluent Pumps are designed to
transport screened effluent (with low TSS counts) from septic tanks or
separate dosing tanks. All our pumps are constructed of lightweight,
corrosion-resistant stainless steel and engineered plastics; all are field-
serviceable and repairable with common tools; and all 60-Hz PF Series
models are CSA certified to the U.S. and Canadian safety standards for
effluent pumps, meeting UL requirements.
Orenco’s Effluent Pumps are used in a variety of applications, including
pressurized drainfields, packed bed filters, mounds, aerobic units, effluent
irrigation, effluent sewers, wetlands, lagoons, and more. These pumps
are designed to be used with a Biotube® pump vault or after a secondary
treatment system.
Features/Specifications
To specify this pump for your installation, require the following:
• Minimum 24-hour run-dry capability with no deterioration in pump life
or performance*
• Patented 1⁄8-inch (3-mm) bypass orifice to ensure flow recirculation
for motor cooling and to prevent air bind
• Liquid end repair kits available for better long-term cost of ownership
• TRI-SEAL™ floating impeller design on 10, 15, 20, and 30 gpm
(0.6, 1.0, 1.3, and 1.9 L/sec) models; floating stack design on 50 and
75 gpm (3.2 and 4.7 L/sec) models
• Franklin Electric Super Stainless motor, rated for continuous use and
frequent cycling
• Type SOOW 600-V motor cable
• Five-year warranty on pump or retrofit liquid end from date of manu-
facture against defects in materials or workmanship
* Not applicable for 5-hp (3.73 kW) models
Standard Models
See specifications chart, pages 2-3, for a list of standard pumps. For
a complete list of available pumps, call Orenco.
Product Code Diagram
PF -
Nominal flow, gpm (L/sec):
10 = 10 (0.6) 15 = 15 (1.0)
20 = 20 (1.3) 30 = 30 (1.9)
50 = 50 (3.2) 75 = 75 (4.7)
Pump, PF Series
Frequency:
1 = single-phase 60 Hz
3 = three-phase 60 Hz
5 = single-phase 50 Hz
Voltage, nameplate:
1 = 115* 200 = 200
2 = 230† 4 = 460
Horsepower (kW):
03 = 1⁄3 hp (0.25) 05 = ½ hp (0.37)
07 = ¾ hp (0.56) 10 = 1 hp (0.75)
15 = 1-½ hp (1.11) 20 = 2 hp (1.50)
30 = 3 hp (2.24) 50 = 5 hp (3.73)
Cord length, ft (m):‡
Blank = 10 (3) 20 = 20 (6)
30 = 30 (9) 50 = 50 (15)
* ½-hp (0.37kW) only
†220 volts for 50 Hz pumps
‡Note: 20-foot cords are available only for single-phase pumps through 1-½ hp
Franklin
Super Stainless
Motor
Franklin
Liquid End
Discharge Connection
Bypass Orifice
Suction Connection
LR80980
LR2053896
Powered by
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 2 of 6
Specifications, 60 Hz
Pump Model
PF100511 10 (0.6) 0.50 (0.37) 1 115 120 12.7 12.7 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF100512 10 (0.6) 0.50 (0.37) 1 230 240 6.3 6.3 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF10053200 10 (0.6) 0.50 (0.37) 3 200 208 3.8 3.8 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF100712 4, 5 10 (0.6) 0.75 (0.56) 1 230 240 8.3 8.3 8 1 ¼ in. GFP 25.9 (658) 17 (432) 30 (14) 300
PF10073200 4, 5 10 (0.6) 0.75 (0.56) 3 200 208 5.1 5.2 8 1 ¼ in. GFP 25.4 (645) 17 (432) 31 (14) 300
PF101012 5, 6 10 (0.6) 1.00 (0.75) 1 230 240 9.6 9.6 9 1 ¼ in. GFP 27.9 (709) 18 (457) 33 (15) 100
PF10103200 5, 6 10 (0.6) 1.00 (0.75) 3 200 208 5.5 5.5 9 1 ¼ in. GFP 27.3 (693) 18 (457) 37 (17) 300
PF102012 5, 6, 7, 8 10 (0.6) 2.00 (1.49) 1 230 240 12.1 12.1 18 1 ¼ in. SS 39.5 (1003) 22 (559) 48 (22) 100
PF102032 5, 6, 8 10 (0.6) 2.00 (1.49) 3 230 240 7.5 7.6 18 1 ¼ in. SS 37.9 (963) 20 (508) 44 (20) 300
PF10203200 5, 6, 8 10 (0.6) 2.00 (1.49) 3 200 208 8.7 8.7 18 1 ¼ in. SS 37.9 (963) 20 (508) 44 (20) 300
PF150311 15 (1.0) 0.33 (0.25) 1 115 120 8.7 8.8 3 1 ¼ in. GFP 19.5 (495) 15 (380) 23 (10) 300
PF150312 15 (1.0) 0.33 (0.25) 1 230 240 4.4 4.5 3 1 ¼ in. GFP 19.5 (495) 15 (380) 23 (10) 300
PF200511 20 (1.3) 0.50 (0.37) 1 115 120 12.3 12.5 4 1 ¼ in. GFP 22.3 (566) 18 (457) 25 (11) 300
PF200512 20 (1.3) 0.50 (0.37) 1 230 240 6.4 6.5 4 1 ¼ in. GFP 22.5 (572) 18 (457) 26 (12) 300
PF20053200 20 (1.3) 0.50 (0.37) 3 200 208 3.7 3.8 4 1 ¼ in. GFP 22.3 (566) 18 (457) 26 (12) 300
PF201012 4, 5 20 (1.3) 1.00 (0.75) 1 230 240 10.5 10.5 7 1 ¼ in. GFP 28.4 (721) 20 (508) 33 (15) 100
PF20103200 4, 5 20 (1.3) 1.00 (0.75) 3 200 208 5.8 5.9 7 1 ¼ in. GFP 27.8 (706) 20 (508) 33 (15) 300
PF201512 4, 5 20 (1.3) 1.50 (1.11) 1 230 240 12.4 12.6 9 1 ¼ in. GFP 34.0 (864) 24 (610) 41 (19) 100
PF20153200 4, 5 20 (1.3) 1.50 (1.11) 3 200 208 7.1 7.2 9 1 ¼ in. GFP 30.7 (780) 20 (508) 35 (16) 300
PF300511 30 (1.9) 0.50 (0.37) 1 115 120 11.8 11.8 3 1 ¼ in. GFP 21.3 (541) 20 (508) 28 (13) 300
PF300512 30 (1.9) 0.50 (0.37) 1 230 240 6.2 6.2 3 1 ¼ in. GFP 21.3 (541) 20 (508) 25 (11) 300
PF30053200 30 (1.9) 0.50 (0.37) 3 200 208 3.6 3.6 3 1 ¼ in. GFP 21.3 (541) 20 (508) 25 (11) 300
PF300712 30 (1.9) 0.75 (0.56) 1 230 240 8.5 8.5 5 1 ¼ in. GFP 24.8 (630) 21 (533) 29 (13) 300
PF30073200 30 (1.9) 0.75 (0.56) 3 200 208 4.9 4.9 5 1 ¼ in. GFP 24.6 (625) 21 (533) 30 (14) 300
PF301012 4 30 (1.9) 1.00 (0.75) 1 230 240 10.4 10.4 6 1 ¼ in. GFP 27.0 (686) 22 (559) 32 (15) 100
PF30103200 4 30 (1.9) 1.00 (0.75) 3 200 208 5.8 5.8 6 1 ¼ in. GFP 26.4 (671) 22 (559) 33 (15) 300
PF301512 4, 5 30 (1.9) 1.50 (1.11) 1 230 240 12.6 12.6 8 1 ¼ in. GFP 32.8 (833) 24 (610) 40 (18) 100
PF30153200 4, 5 30 (1.9) 1.50 (1.11) 3 200 208 6.9 6.9 8 1 ¼ in. GFP 29.8 (757) 22 (559) 34 (15) 300
PF301534 4, 5 30 (1.9) 1.50 (1.11) 3 460 480 2.8 2.8 8 1 ¼ in. GFP 29.5 (685) 22 (559) 34 (15) 300
PF302012 5, 6, 7 30 (1.9) 2.00 (1.49) 1 230 240 11.0 11.0 10 1 ¼ in. SS 35.5 (902) 26 (660) 44 (20) 100
PF30203200 5, 6 30 (1.9) 2.00 (1.49) 3 200 208 9.3 9.3 10 1 ¼ in. SS 34.0 (864) 24 (610) 41 (19) 300
PF303012 5, 6, 7, 8 30 (1.9) 3.00 (2.23) 1 230 240 16.8 16.8 14 1 ¼ in. SS 44.5 (1130) 33 (838) 54 (24) 100
PF303032 5, 6, 8 30 (1.9) 3.00 (2.23) 3 230 240 10.0 10.1 14 1 ¼ in. SS 44.3 (1125) 27 (686) 52 (24) 300
PF305012 5, 6, 7, 8 30 (1.9) 5.00 (3.73) 1 230 240 25.6 25.8 23 1 ¼ in. SS 66.5 (1689) 53 (1346) 82 (37) 100
PF305032 5, 6, 8 30 (1.9) 5.00 (3.73) 3 230 240 16.6 16.6 23 1 ¼ in. SS 60.8 (1544) 48 (1219) 66 (30) 300
PF30503200 5, 6, 8 30 (1.9) 5.00 (3.73) 3 200 208 18.7 18.7 23 1 ¼ in. SS 60.8 (1544) 48 (1219) 66 (30) 300
PF500511 50 (3.2) 0.50 (0.37) 1 115 120 12.1 12.1 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300
PF500512 50 (3.2) 0.50 (0.37) 1 230 240 6.2 6.2 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300
PF500532 50 (3.2) 0.50 (0.37) 3 230 240 3.0 3.0 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
PF50053200 50 (3.2) 0.50 (0.37) 3 200 208 3.7 3.7 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
PF500534 50 (3.2) 0.50 (0.37) 3 460 480 1.5 1.5 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
PF500712 50 (3.2) 0.75 (0.56) 1 230 240 8.5 8.5 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300
PF500732 50 (3.2) 0.75 (0.56) 3 230 240 3.9 3.9 3 2 in. SS 23.7 (602) 25 (635) 32 (15) 300
PF50073200 50 (3.2) 0.75 (0.56) 3 200 208 4.9 4.9 3 2 in. SS 23.1 (587) 26 (660) 32 (15) 300Design gpm (L/sec)Horsepower (kW)PhaseNameplate voltageActual voltageDesign flow ampsMax ampsImpellersDischarge size and material 1Length, in. (mm)Min. liquid level, 2 in. (mm)Weight, 3 lb (kg)Rated cycles/day
Technical Data Sheet Orenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 3 of 6
Specifications, 60 Hz (continued)
Pump Model
PF500734 50 (3.2) 0.75 (0.56) 3 460 480 1.8 1.8 3 2 in. SS 34.8 (884) 25 (635) 31 (14) 300
PF501012 50 (3.2) 1.00 (0.75) 1 230 240 10.1 10.1 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100
PF50103200 50 (3.2) 1.00 (0.75) 3 200 208 5.7 5.7 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300
PF501034 50 (3.2) 1.00 (0.75) 3 460 480 2.2 2.2 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300
PF5015124 50 (3.2) 1.50 (1.11) 1 230 240 12.5 12.6 5 2 in. SS 32.5 (826) 30 (762) 41 (19) 100
PF501532004 50 (3.2) 1.50 (1.11) 3 200 208 7.0 7.0 5 2 in. SS 29.3 (744) 26 (660) 35 (16) 300
PF503012 4, 5, 7, 8 50 (3.2) 3.00 (2.23) 1 230 240 17.7 17.7 8 2 in. SS 43.0 (1092) 37 (940) 55 (25) 100
PF50303200 4, 5, 8 50 (3.2) 3.00 (2.23) 3 200 208 13.1 13.1 8 2 in. SS 43.4 (1102) 30 (762) 55 (25) 300
PF503034 4, 5, 8 50 (3.2) 3.00 (2.23) 3 460 480 5.3 5.3 8 2 in. SS 40.0 (1016) 31 (787) 55 (25) 300
PF505012 5,6,7,8 50 (3.2) 5.00 (3.73) 1 230 240 26.2 26.4 13 2 in. SS 65.4 (1661) 55 (1397) 64 (29) 300
PF505032 5,6,7,8 50 (3.2) 5.00 (3.73) 3 230 240 16.5 16.5 13 2 in. SS 59.3 (1506) 49 (1245) 64 (29) 300
PF751012 75 (4.7) 1.00 (0.75) 1 230 240 9.9 10.0 3 2 in. SS 27.0 (686) 27 (686) 34 (15) 100
PF751512 75 (4.7) 1.50 (1.11) 1 230 240 12.1 12.3 4 2 in. SS 33.4 (848) 30 (762) 44 (20) 100
Specifications, 50 Hz
Pump Model
PF100552 10 (0.6) 0.50 (0.37) 1 220 230 3.9 4.1 6 1 ¼ in. GFP 23.0 (584) 17 (432) 26 (12) 300
PF100752 4, 5 10 (0.6) 0.75 (0.56) 1 220 230 6.2 6.2 9 1 ¼ in. GFP 26.8 (658) 17 (432) 30 (14) 300
PF101552 5, 6 10 (0.6) 1.50 (1.11) 1 220 230 10.5 11.4 18 1 ¼ in. SS 39.5 (1003) 22 (559) 46 (21) 300
PF300552 30 (1.9) 0.50 (0.37) 1 220 230 4.1 4.1 4 1 ¼ in. GFP 22.5 (572) 19 (483) 26 (12) 300
PF300752 30 (1.9) 0.75 (0.56) 1 220 230 6.1 6.1 5 1 ¼ in. GFP 24.8 (630) 19 (483) 29 (13) 300
PF301052 30 (1.9) 1.00 (0.75) 1 220 230 7.4 7.4 7 1 ¼ in. GFP 28.4 (721) 20 (508) 32 (15) 100
PF301552 4, 5 30 (1.9) 1.50 (1.11) 1 220 230 9.3 9.3 8 1 ¼ in. GFP 35.4 (899) 24 (610) 40 (18) 100
PF500552 50 (3.2) 0.50 (0.37) 1 220 230 4.0 4.0 2 2 in. SS 20.3 (516) 25 (635) 29 (13) 300
PF500752 50 (3.2) 0.75 (0.56) 1 220 230 6.3 6.4 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300
PF501052 50 (3.2) 1.00 (0.75) 1 220 230 7.3 7.4 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100
PF501552 50 (3.2) 1.50 (1.11) 1 220 230 9.1 9.1 5 2 in. SS 32.5 (826) 30 (762) 42 (19) 100
PF751052 75 (3.2) 1.00 (0.75) 1 220 230 7.3 7.3 4 2 in. SS 30.0 (762) 27 (686) 34 (15) 100
1 GFP = glass-filled polypropylene; SS = stainless steel. The 1 ¼-in. NPT GFP discharge is 2 7⁄8 in. octagonal across flats; the 1 ¼-in. NPT SS discharge is 2 1⁄8 in. octagonal across flats; and the
2-in. NPT SS discharge is 2 7⁄8 in. hexagonal across flats. Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® discharge hose and valve assemblies. Consult your Orenco
Distributor about fittings to connect hose and valve assemblies to metric-sized piping.
2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® Pump Vault or Universal Flow Inducer. In other applications, minimum liquid level should be top of pump. Consult
Orenco for more information.
3 Weight includes carton and 10-ft (3-m) cord.
4 High-pressure discharge assembly required.
5 Do not use cam-lock option (Q) on discharge assembly.
6 Custom discharge assembly required for these pumps. Contact Orenco.
7 Capacitor pack (sold separately or installed in a custom control panel) required for this pump. Contact Orenco.
8 Torque locks are available for all pumps, and are supplied with 3-hp and 5-hp pumps. Design gpm (L/sec)Horsepower (kW)PhaseNameplate voltageActual voltageDesign flow ampsMax ampsImpellersDischarge size and material 1Length, in. (mm)Min. liquid level, 2 in. (mm)Weight, 3 lb (kg)Rated cycles/day
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 4 of 6
Materials of Construction
Discharge Glass-filled polypropylene or stainless steel
Discharge bearing Engineered thermoplastic (PEEK)
Diffusers Glass-filled PPO (Noryl GFN3)
Impellers Celcon® acetal copolymer on 10-, 20, and 30-gpm models; 50-gpm impellers are Noryl GFN3
Intake screen Polypropylene
Suction connection Stainless steel
Drive shaft 7/16 inch hexagonal stainless steel, 300 series
Coupling Sintered stainless steel, 300 series
Shell Stainless steel, 300 series
Motor Franklin motor exterior constructed of stainless steel. Motor filled with deionized water and propylene glycol for constant lubrication. Hermetically
sealed motor housing ensures moisture-free windings. All thrust absorbed by Kingsbury-type thrust bearing. Rated for continuous duty. Single-
phase motors and 200 and 230 V 3-phase motors equipped with surge arrestors for added security. Single-phase motors through 1.5 hp
(1.11 kW) have built-in thermal overload protection, which trips at 203-221˚ F (95-105˚ C).
Using a Pump Curve
A pump curve helps you determine the best pump for your system. Pump curves show the relationship between flow (gpm or L/sec) and pressure
(total dynamic head, or TDH), providing a graphical representation of a pump’s optimal performance range. Pumps perform best at their nominal
flow rate — the value, measured in gpm, expressed by the first two numerals in an Orenco pump nomenclature. The graphs in this section show
optimal pump operation ranges with a solid line. Flow flow rates outside of these ranges are shown with a dashed line. For the most accurate
pump specification, use Orenco’s PumpSelect™ software.
Pump Curves, 60 Hz Models
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
24 81012141660
800
700
600
500
400
300
200
100 PF1005-FC
w/ ¼" flow
controller
PF10 Series, 60 Hz, 0.5 - 2.0 hp
PF1007
PF1010
PF1020
PF1005
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
36 12 15 18 21 2490
160
140
120
100
80
60
40
20
0
PF1503
PF15 Series, 60 Hz, 0.3 hp
Technical Data Sheet Orenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 5 of 6Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
5102025303540150
400
350
300
250
200
150
100
50
0
PF2005
PF2010
PF2015
PF20 Series, 60 Hz, 0.5 - 1.5 hp
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
510202530354045150
800
900
700
600
500
400
300
200
100
0
PF3005
PF3007
PF3010
PF3015
PF3020
PF3030
PF3050 PF30 Series, 60 Hz, 0.5 - 5.0 hp
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
450
400
350
300
250
200
150
100
50
0 10 02040506070809030
PF5050
PF5030
PF5015
PF5010
PF5007
PF5005
PF50 Series, 60 Hz, 0.5 - 5.0 hp
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
10 20 40 50 60 70 80 90 100300
80
90
100
70
60
50
40
30
20
10
0
PF75 Series, 60 Hz, 1.0 - 1.5 hpPF7515
PF7510
60 Hz Models (continued)
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 6 of 6Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.90.80.70.60.50.40.30.20.10
13119.57.96.34.83.21.6
120
100
80
60
40
20
0
160
180
140
394
328
262
197
131
66
525
459
PF100552
PF100752
PF101552
PF1005-FC
w/ 6mm flow
controller
PF10 Series, 50 Hz, 0.37 - 1.11 kW
Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.8 1.2 1.6 2.0 2.40.40
13 19 25 326.3
60
80
100
120
40
20
0
197
262
328
131
66
PF301552
PF301052
PF300752
PF300552
PF30 Series, 50 Hz, 0.37 - 1.11 kW
Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.5 1.0 2.0 2.5 3.0 3.5 4.0 4.51.50
7.9 16 32 40 48 56 6324
40
45
35
30
25
20
15
10
5
0
131
115
98
82
66
49
33
16
PF501552
PF501052
PF500752
PF500552
PF50 Series, 50 Hz, 0.37 - 1.11 kW
Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.6 1.2 2.4 3.0 3.6 4.2 5.44.8 6.01.80
10 19 4838 57 67 76 8629
27
30
24
21
18
15
12
9
6
3
0
89
79
69
59
49
39
30
20
PF751052
PF75 Series, 50 Hz, 0.75 kW
Pump Curves, 50 Hz Models
Introduction
Orenco’s automatic distributing valve assemblies, pressurized with small high-head effluent
pumps, are useful for distributing effluent to multiple zones. These zones can be segments
of sand filter manifolds, drainfields, or other effluent distribution systems. Distributing
valve assemblies can substantially simplify the design and installation of a distribution sys-
tem and reduce installation costs. This is particularly true where a distributing valve assem-
bly is used instead of multiple pumps and/or electrically operated valves. Additionally, a
reduction in long term operation and maintenance costs is realized due to a reduced size
and/or number of pumps. More even distribution can be achieved on sloping sites by zoning
laterals at equal elevations. This eliminates drainback to lower lines and the unequal distrib-
ution of effluent that occurs at the beginning of a cycle.
Valve Operation
The valve itself has only a few moving parts, requires no electricity, and alternates automati-
cally each cycle. Refer to Figure 1 for the following valve operation description. The flow
of the incoming effluent forces the rubber flap disk 1 to seat against the valve bottom 2.
The opening 3 in the rubber flap disk aligns with an opening in the valve bottom to allow
flow to only one valve outlet. The stem 4 houses a stainless steel spring which pushes the
rubber flap disk away from the valve bottom after the flow of effluent stops. The stem acts
as a cam follower and rotates the rubber flap disk as the stem is raised and lowered through
the cam 5. The force from the flow of effluent pushes the stem down through the cam and
the stainless steel spring pushes the stem back up through the cam when the flow of effluent
stops. Each linear motion of the stem allows the rubber flap disk to rotate half the distance
necessary to reach the next outlet. When there is no flow, the rubber flap disk is in the “up”
position and is not seated against the valve bottom.
5
4
3
2
1
Inlet
Outlets
Figure 1:
6000 Series Valve
Orenco Automatic Distributing
Valve Assemblies
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 1 of 6
For Wastewater Effluent Systems
This article may describe design criteria that was in effect at the time the article was written. FOR CURRENT DESIGN
CRITERIA, call Orenco Systems, Inc. at 1-800-348-9843.
The Distributing Valve Assembly
The Orenco Automatic Distributing Valve Assembly combines the distributing valve itself and sever-
al other components to give a complete preassembled unit that is easy to install, monitor, and main-
tain. Figure 2 shows a complete assembly. Because distributing valves with several outlets can be
difficult to line up and glue together in the field, the discharge lines in the assemblies are glued in
place at Orenco. The unions (1) allow removal and maintenance of the valve. The clear PVC pipe
sections (2) give a visual check of which discharge line is being pressurized. The inlet ball valve (3)
allows a quick, simple method to test for proper valve cycling. The ball valve also stops the flow of
effluent in case the pump is activated unexpectedly during maintenance or inspection. Check valves
may be necessary on the discharge lines. Use of check valves is discussed in the valve positioning
section.
Valve Assembly Hydraulics
Liquid flowing through the valve assembly must pass through fairly small openings and make several
changes in direction. Because of this, headlosses through the valve assembly are fairly high. Table 1
gives the headloss equations for several different assemblies and Figure 3 shows the graphical repre-
sentations of these equations. Orenco recommends that high-head turbine pumps be used to pressur-
ize the valve assemblies to ensure enough head is available for proper system operation. High-head
turbine pumps are also recommended because the use of a distributing valve usually requires more
frequent pump cycling. The high-head turbine pumps are designed for high cycling systems and will
outlast conventional effluent pumps by a factor of 10 or more in a high cycling mode. Furthermore,
the high-head turbine pump intake is 12 inches or more above the bottom of the pump and tends to
prevent any settled solids from being pumped into the distribution valve and obstructing its opera-
tion. A minimum flow rate through the distributing valve is required to ensure proper seating of the
rubber flap disk. Minimum flow rates for the various models are given in Table 1.
Figure 2:
Orenco Distributing Valve Assembly (6000 Series Valve)
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 2 of 6
Table 1. Automatic Distributing Valve Assembly Headloss Equations
Model Series Equation Operating Range (gpm)
V4400A HL = 0.085 x Q1.45 10 - 40
V4600A HL = 0.085 x Q1.58 10 - 25
V6400A HL = 0.0045 x Q2 + 3.5 x (1 - e-0.06Q) 15 - 70
V6600A HL = 0.0049 x Q2 + 5.5 x (1 - e-0.1Q) 15 - 70
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 3 of 6
0
5
10
15
20
25
30
35
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
Flow (gpm)Head Loss Through Assembly (ft.)V4600A
V4400A
V6600A
V6400A
The Pumping System
Although the distributing valve was designed for the irrigation industry, it has started to gain fairly
wide acceptance in the effluent pumping industry. However, because of the mechanical movements
of the valve, it is necessary to take steps to prevent solids from reaching the distributing valve that
may impede the operation of the valve. Orenco Biotube®Pump Vaults — when properly sized and
installed — provide the necessary protection to prevent valve malfunction. The Biotube®pump vault
accepts effluent only from the clear zone between a tank’s scum and sludge layers and then filters
this effluent through a very large surface area screen cartridge. Without this protection in effluent
systems, the valve has very little chance of reliable long-term operation.
Figure 3:
Automatic distributing valve assembly headloss curves
Valve Positioning
The physical position of the valve in relation to the pump and the discharge point is very important
for proper valve operation. The most reliable operation occurs when the valve is placed at the high
point in the system and as close to the pump as possible. The transport line between the pump and
valve should be kept full if possible. If the line is empty at the beginning of each cycle, pockets of
air during filling can cause random rotation of the valve. The valve is particularly vulnerable to this
erratic rotation with empty lines that are long and not laid at a constant grade. An ideal valve loca-
tion is shown in Figure 4.
If the final discharge point is more than about 2 feet above the valve and the system does not drain
back into the dosing tank, check valves should be installed on the lines immediately following the
valve and a pressure release hole or line should be installed just prior to the valve. This pressure
release hole or line can go into a return line to the dosing tank or to a “minidrainfield” near the valve.
In order for the valve to rotate reliably, no more than about 2 feet of head should remain against the
valve to allow the rubber flap disk to return to its up position. In many cases, it may take from one
minute to several minutes for the pressure in the valve to be lowered enough for proper rotation to
occur. Special care should be taken when installing systems controlled by programmable timers to
ensure cycling does not occur too rapidly. Figure 5 illustrates a valve assembly using check valves.
Pumping downhill to the valve should be avoided unless the transport line is very short and the ele-
vation between the discharge line out of the tank and the valve is less than about 2 feet. If the valve
is located many feet below the dosing tank, random cycling may occur while the transport line drains
through the valve at the end of the cycle. A pressure sustaining valve located just before the distrib-
uting valve may overcome this problem in some instances.
Dosing Tank
Discharge Laterals
Distributing Valve Assembly
Transport Line
Figure 4:
Ideal valve location
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 4 of 6
System Startup
Refer to the Hydrotek Valve booklet that is provided with the distributing valve assembly for the
sequencing of the valve outlets. The transport line should always be flushed with clean water before
installing the valve. Any sand, gravel, or other foreign objects that may have been in the pipe during
installation can easily become lodged in the distributing valve, causing malfunction.
With the pump running, alternately close and open the ball valve on the distributing valve assembly
to check proper rotation of the valve. (Note: If check valves are used on the lines after the distribut-
ing valve, the pump may need to be turned on and off to allow the pressure to be released from the
valve.) If visual operation of which zone is operating is not possible, watch the clear pipe on each
line for indication of which zone is operating.
Maintenance
Annually check for proper operation by following procedures listed in the Hydrotek Valve booklet
and system startup procedures listed above.
Troubleshooting
1. PROBLEM: Valve does not change or cycle to next zone or outlet
CAUSE: The stem and disk assembly is not rotating when water flow is turned off and then
back on.
SOLUTION 1: Ensure that there is no debris inside the cam. Clean and carefully reinstall the cam.
SOLUTION 2: If fewer than the maximum number of outlets are being used, check the installation
of the cam. Ensure that the stem and disk assembly is not being held down by an
improperly installed cam. Refer to the cam replacement instructions.
h
Check Valves if h>2'-0"
Distributing Valve Assembly
Transport Line
Dosing Tank
Pressure Release
Line if h>2'-0"
Discharge Laterals
Figure 5:
Valve assembly below final discharge point
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 5 of 6
SOLUTION 3: Remove the valve top and check for proper movement of stem and disk assembly.
Check for and remove any debris or foreign objects that may jam or retard the
movement of the disk.
SOLUTION 4: Check for freedom of movement of stem and disk assembly up and down over the
center pin in bottom of valve. Scale deposits may build up on the pin and hold stem
and disk assembly down. Clean pin and again check for freedom of movement.
SOLUTION 5: Be sure that all operating outlets are not capped and that the flow to operating zones
is not restricted in any manner. This would cause pressure to build up in the valve
and lock the stem and disk assembly in the down position.
SOLUTION 6: The backflow of water from uphill lines may be preventing the valve from cycling
properly. This can happen when the valve is placed too far below an elevated line.
If the valve cannot be placed close to the high point of the system, a check valve
should be installed near the valve in the outlet line that runs uphill from the valve
and a drain line installed just prior to the valve to relieve the pressure.
2. PROBLEM: Water comes out of all the valve outlets
CAUSE: Stem and disk assembly not seating properly on valve outlet.
SOLUTION 1: Check for sufficient water flow. A minimum flow rate is required to properly seat
the disk as shown in Table 1.
SOLUTION 2: Remove the valve top and check the inside walls to ensure that nothing is interfering
with the up and down movement of the stem and disk assembly inside the valve.
SOLUTION 3: Make sure that the operating outlets are not capped and that the flow to the operat-
ing zones are not restricted in any manner.
3. PROBLEM: Valve skips outlets or zones
CAUSE: Pumping into an empty transport line — especially downhill — may cause the valve
to skip outlets from pockets of air allowing the rubber flap disk to raise during a
cycle.
SOLUTION 1: Keep the transport line full.
SOLUTION 2: If the line must remain empty between cycles, use a larger diameter transport line
laid at a constant grade to prevent air pockets from forming.
CAUSE: The stem and disk assembly is being advanced past the desired outlet.
SOLUTION 1: Ensure that the correct cam for the desired number of zones is installed and that the
outlet lines are installed to the correct outlet ports of the valve as indicated by the
zone numbers on the top of the cam.
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 6 of 6
Distributing Valves
General
Orenco’s Automatic Distributing Valve Assemblies are
mechanically operated and sequentially redirect the
pump’s flow to multiple zones or cells in a distribution
field. Valve actuation is accomplished by a combination
of pressure and flow. Automatic Distributing Valve
Assemblies allow the use of smaller horsepower pumps
on large sand filters and drainfields. For example, a large
community drainfield requiring 300 gpm can use a six-line
Valve Assembly to reduce the pump flow rate requirement
to only 50 gpm.
Orenco only warrants Automatic Distributing Valves when
used in conjunction with High-Head Effluent Pumps with
Biotube®Pump Vaults to provide pressure and flow
requirements, and to prevent debris from fouling valve
operation. An inlet ball valve and a section of clear pipe
and union for each outlet are provided for a complete
assembly that is easy to maintain and monitor. Ideal
valve location is at the high point in the system. Refer to
Automatic Distributing Valve Assemblies (NTP-VA-1) for
more information.
Standard Models
V4402A, V4403A, V4404A, V4605A, V4606A, V6402A, V6403A,
V6404A, V6605A, V6606A.
Nomenclature
Submittal
Data Sheet
Side View
ball valve
elbow
Top View
coupling
clear pipe
distributing valve
union
Bottom View
elbows
Specifications
Materials of Construction
All Fittings:Sch. 40 PVC per ASTMspecification
Unions:Sch. 80 PVCper ASTMspecification
Ball Valve:Sch. 40 PVCper ASTMspecification
Clear Pipe:Sch. 40 PVCper ASTMspecification
V4XXX Distributing Valves: High-strength noncorrosive ABSpolymer and stainless steel
V6XXX Distributing Valves: High-strength noncorrosive ABSpolymer, stainless steel, and die cast metal
NSU-SF-VA-1
Rev. 3.0, © 4/03
Page 1 of 2
Applications
Automatic Distributing Valve Assemblies are used to pressurize
multiple zone distribution systems including textile filters, sand
filters and drainfields.
V
Indicates assembly
Model series:
44 = 4400 series (2-4 outlets)
46 = 4600 series (5-6 outlets)
64 = 6400 series (2-4 outlets)
66 = 6600 series (5-6 outlets)
Distributing valve
Number of active outlets
A
Distributing Valves (continued)
Flow (gpm)Head Loss Through Assembly (ft.)0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
0
5
10
15
20
25
30
35
V4400A
V6600A
V6400A
V4600A
NSU-SF-VA-1
Rev. 3.0, © 4/03
Page 2 of 2
Model Inlet Size (in.) Outlets Size (in.) Flow range (gpm) Max Head (ft.) Min. Enclosure
V4402A 1.25 1.25 10 - 40 170 VB1217
V4403A 1.25 1.25 10 - 40 170 VB1217
V4404A 1.25 1.25 10 - 40 170 VB1217
V4605A 1.25 1.25 10 - 25 170 RR2418
V4606A 1.25 1.25 10 - 25 170 RR2418
V6402A 1.5 1.5 15 - 100 345 RR2418
V6403A 1.5 1.5 15 - 100 345 RR2418
V6404A 1.5 1.5 15 - 100 345 RR2418
V6605A 1.5 1.5 15 - 100 345 RR2418
V6606A 1.5 1.5 15 - 100 345 RR2418
Quick4PLUSPLUS
STD LOW PROFILE CHAMBER
Failure to comply with these installation instructions may invalidate the warranty.
Contact Infiltrator Systems’ Technical Services Department for assistance at 800-221-4436.
Installing the Chambers and End Caps
1.To allow pressure laterals to drain after each dose, drill a hole in the
bottom of the pipe at the end of the pressure line. Place the snap-off
splash plate or a paving block at the bottom of the trench to protect the
infiltrative surface from erosion.
2.With a hole saw, drill out the
appropriate diameter hole to
accommodate the pressure lat-
eral pipe.
3.Insert the pressure lateral pipe
into the end cap’s drilled opening
and slide it into the manifold
pipe. Glue the pressure lateral
pipe to the manifold pipe.
4. With the pressure lateral pipe through the end cap, place the back
edge of the end cap over the inlet end of the first chamber. Be sure to
line up the locking pins on the top of both the chamber and end cap.
Before You Begin
Quick4 Plus Standard Low Profile (LP) Chambers can only be
installed according to state and/or local regulations. Soil and site
conditions must be approved prior to installation. Conduct a
thorough site evaluation to determine proper sizing and siting of
the system before installation.
Materials and Equipment Needed
Quick4 Plus Standard LP
Chambers
Quick4 Plus All-in-One or Q4
Plus Endcaps
PVC Pipe and Couplings
Backhoe
Laser, Transit or Level
Tape measure
Shovel and Rake
Utility Knife
1 1/4-inch Drywall Screws*
Screw Gun*
Small Valve-cover Box*
4-inch Cap Inspection Port
* Optional
These guidelines for construction machinery must be
followed during installation:
Avoid direct contact with chambers when using construction
equipment. Chambers require a 12-inch minimum of compacted cover
to support a wheel load rating of 16,000 lbs/axle or equivalent to an
H-10 AASHTO load rating.
Only drive across the trenches when necessary. Never drive
wheeled machinery over chambers.
Avoid stones larger than 3 inches in diameter in backfill. Remove
stones this size or larger that are in contact with chambers.
5. (Method A)Secure the pres-
sure lateral pipe to the top of the
first chamber with a plastic pipe
strap at the outlet end of the unit.
Slide the strap up through a slot
in the chamber top, down through
the other slot, and cinch the two
ends around the pipe.
6. (Method B)With the holes
pointing up, stabilize the pressure
lateral pipe on the ground to
prevent it from moving.
7. Lift and place the next
chamber onto the previous one at a 45-degree angle. Line up the
chamber end between the connector hook and locking pin at the top of
the first chamber. Lower it to the ground to engage the interlocks.
8. (Method A)Secure the lateral pipe to the top of the next chamber
once in place. Follow the same method in Step 5.
9. Continue interlocking chambers and securing the pipe until the trench
is completed.
10. Before attaching the final end cap, it may be necessary to remove
the tongue of the connector hook on the last chamber with a pair of
pliers depending on your pipe diameter.
11.Insert the pressure lateral
pipe through the hole in the final
end cap and slide the end cap
toward the last chamber. Lift the
end cap over the modified con-
nector hook and push straight
down to secure it to the chamber.
Note: If cleanout extensions are
required, use a hole saw to cut a
hole in the top of the Quick4
Plus All-in-One Endcap so the
pressure lateral pipe with an
elbow can extend to the ground
surface. For cleanout access,
use the “Installing Optional
Inspection Ports” section in the
general installation instructions.
12.If installing multiple rows of
chambers, follow Steps 1-9 to lay
the next row of chambers
parallel to the first. Keep a
minimum separation distance
between each row of chambers
as required by local code.
2
Drill pressure pipe hole.
Quick4®Plus Standard Low Profile Chambers
Pressure Distribution Systems Installation Instructions
5
Secure pressure pipe.
VALVE BOX (OR IRRIGATION BOX)
ACCESS FOR DRAINFIELD MAINTENANCE AND FLUSHING
QUICK4 PLUS STANDARD LP
11
Lateral pipe through end cap.
1" PRESSURE LATERAL (TYP.)
2" PRESSURE LATERAL (TYP.)
1” OR 2” TRENCH BOTTOM
PIPE PLACEMENT
Note: Health departments may
require a wet-run pressure check
to be done prior to chamber
installation when the pipe is lay-
ing on the ground. Check with
your local health department for
the proper procedure.
4
Place end cap over inlet end.
Distributed By:
6 Business Park Road • P.O. Box 768
Old Saybrook, CT 06475
860-577-7000 • FAX 860-577-7001
1-800-221-4436
www.infiltratorsystems.com
U.S. Patents: 4,759,661; 5,017,041; 5,156,488; 5,336,017; 5,401,116; 5,401,459; 5,511,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending. Infiltrator, Equalizer, and
Quick4 are registered trademarks of Infiltrator Systems Inc. Infiltrator is a registered trademark in France. Infiltrator Systems Inc. is a registered trademark in Mexico.
© 2009 Infiltrator Systems Inc. All rights reserved. Printed in U.S.A. PLUS030709AG-0
(a) The structural integrity of each chamber, end cap and other accessory manufactured by Infiltrator (“Units”), when installed and operated in a leachfield of an onsite
septic system in accordance with Infiltrator's instructions, is warranted to the original purchaser (“Holder”) against defective materials and workmanship for one year from the
date that the septic permit is issued for the septic system containing the Units; provided, however, that if a septic permit is not required by applicable law, the warranty perod
will begin upon the date that installation of the septic system commences. To exercise its warranty rights, Holder must notify Infiltrator in writing at its Corporate Headquarters
in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. Infiltrator will supply replacement Units for Units determined by Infiltrator to be covered by this
Limited Warranty. Infiltrator’s liability specifically excludes the cost of removal and/or installation of the Units.
(b) THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS,
INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
(c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than Infiltrator. The Limited Warranty does not extend to inciden-
tal, consequential, special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages, including loss of production and profits, labor and
materials, overhead costs, or other losses or expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty coverage are damage to the
Units due to ordinary wear and tear, alteration, accident, misuse, abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which are not
permitted by the installation instructions; failure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the
system containing the Units; failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, improper grease disposal, or improp-
er operation; or any other event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails to comply with all of the terms set forth in this Limited Warranty.
Further, in no event shall Infiltrator be responsible for any loss or damage to the Holder, the Units, or any third party resulting from installation or
shipment, or from any product liability claims of Holder or any third party. For this Limited Warranty to apply, the Units must be installed in
accordance with all site conditions required by State and local codes; all other applicable laws; and Infiltrator’s installation instructions.
(d) No representative of Infiltrator has the authority to change or extend this Limited Warranty. No warranty applies to any party other than the original Holder.
* * * * * * *
The above represents the standard Limited Warranty offered by Infiltrator. A limited number of States and counties have different warranty
requirements. Any purchaser of Units should contact Infiltrator's Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase,
to obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units.
Infiltrator Systems, Inc. Limited Warranty
Advantages of Method A
• Pipe and orifice placed closer to the chamber dome offer
improved distribution.
• Pipe positioned at the top of the chamber places it well above
effluent.
• Plastic pipe hanger easily secures pipe in place.
Advantage of Method B
• Pipe resting on the trench bottom allows easy installation and
maintenance.
• Stabilizing “T’s” keep pipe level.
• System promotes efficient pressure checks.
• Pipe resting on the trench bottom allows easier inspections if
monitoring ports are installed.
PRESSURE PIPE WITH
HOLES AT 12 O'CLOCK
(MAY BE INSTALLED ON
EITHER SIDE)
ALL WEATHER PLASTIC
PIPE STRAP WITH 120 POUNDS
TENSILE STRENGTH AT EVERY
CHAMBER CONNECTION
QUICK4 PLUS
STANDARD LP CHAMBER
34"
8"
STABILIZE OR "T" EVERY 10' TO
PREVENT PIPE ROTATION AND
MAINTAIN PROPER PIPE POSITION
3
34"
8"
PRESSURE PIPE WITH
HOLES AT 12 O'CLOCK
(MAY BE INSTALLED ON
EITHER SIDE)
QUICK4 PLUS
STANDARD LP CHAMBER
The Quick4® Plus Standard Low Profile (LP) Chamber
The Quick4 Plus Standard Low
Profile (LP) offers maximum
strength through its four center
structural columns. This chamber
can be installed in a 36-inch-wide
trench. It is shorter in height than
Infiltrator’s other Standard model
chambers, allowing for shallower
installation. Like the original line
of Quick4 chambers, it offers
advanced contouring capability with
its Contour Swivel Connection™,
which permits turns up to 15°, right
or left. The Quick4 Plus All-in-One
8 and Quick4 Plus Endcaps provide
increased flexibility in system design
and configurations.
Maximum Strength
APPROVED in _____________________________________________
Quick4 Plus™ Series
Certified by the International
Association of Plumbing
and Mechanical
Officials (IAPMO)
Quick4 Plus Standard LP Chamber Specifications
Size
34”W x 53”L x 8”H
(864 mm x 1346 mm x 203 mm)
Effective Length
48” (1219 mm)
Louver Height
6.3” (160 mm)
Storage Capacity
32 gal (121 L)
Invert Height
3.3” (84 mm), 9.6” (244 mm)
Quick4 Plus Standard Low Profile (LP) Chamber Benefits:
• Low profile design makes this
chamber ideal for shallow
applications
• Reduces imported fill needed
for cap and fill systems
• Four center structural columns
offer superior strength
• Advanced contouring connections
• Latching mechanism allows
for quick installation
• Four-foot chamber lengths
are easy to handle and install
• Supports wheel loads of
16,000 lbs/axle with 12” of cover
Quick4 Plus All-in-One Periscope Benefits:
• Allows for raised invert
installations
• 180° directional inletting
• 12” raised invert is ideal
for serial applications
Quick4 Plus All-in-One 8 Endcap Benefits:
• May be used at the end of chamber
row for an inlet/outlet or can be
installed mid-trench
• Mid-trench connection feature allows
center feed inletting of chamber rows
• Center-feed connection allows for
easy installation of serial distribution
systems
• Variable pipe connection options
allow for side, end or top inletting
• Piping drill points are set for
gravity or pressure pipe
Quick4 Plus Endcap Benefits:
• Simple, flat design
• Allows installation of a pipe
from the end only
• Piping drill points are set for
gravity or pressure pipe
Contact Infiltrator Water Technologies’ Technical Services Department for assistance at 1-800-221-4436
4 Business Park Road
P.O. Box 768
Old Saybrook, CT 06475
860-577-7000 • Fax 860-577-7001
1-800-221-4436
www.infiltratorwater.com
U.S. Patents: 4,759,661; 5,017,041; 5,156,488; 5,336,017; 5,401,116; 5,401,459; 5,511,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending.
Infiltrator, Equalizer, Quick4, and SideWinder are registered trademarks of Infiltrator Water Technologies. Infiltrator is a registered trademark in France. Infiltrator Water Technologies is a registered trademark in Mexico.
Contour, MicroLeaching, PolyTuff, ChamberSpacer, MultiPort, PosiLock, QuickCut, QuickPlay, SnapLock and StraightLock are trademarks of Infiltrator Water Technologies.
PolyLok is a trademark of PolyLok, Inc. TUF-TITE is a registered trademark of TUF-TITE, INC. Ultra-Rib is a trademark of IPEX Inc.
© 2016 Infiltrator Water Technologies, LLC. All rights reserved. Printed in U.S.A.PLUS01 0816
Quick4 Plus™ Series
INFILTRATOR WATER TECHNOLOGIES, LLC (“INFILTRATOR”)
Infiltrator Water Technologies, LLC STANDARD LIMITED Drainfield WARRANTY
(a) The structural integrity of each chamber, endcap, EZflow expanded polystyrene and/or other
accessory manufactured by Infiltrator (“Units”), when installed and operated in a leachfield of
an onsite septic system in accordance with Infiltrator’s instructions, is warranted to the original
purchaser (“Holder”) against defective materials and workmanship for one year from the date that
the septic permit is issued for the septic system containing the Units; provided, however, that if a
septic permit is not required by applicable law, the warranty period will begin upon the date that
installation of the septic system commences. To exercise its warranty rights, Holder must notify
Infiltrator in writing at its Corporate Headquarters in Old Saybrook, Connecticut within fifteen
(15) days of the alleged defect. Infiltrator will supply replacement Units for Units determined by
Infiltrator to be covered by this Limited Warranty. Infiltrator’s liability specifically excludes the cost
of removal and/or installation of the Units.
(b) THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE
ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
(c) This Limited Warranty shall be void if any part of the chamber system is manufactured by any-
one other than Infiltrator. The Limited Warranty does not extend to incidental, consequential, spe-
cial or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages, including
loss of production and profits, labor and materials, overhead costs, or other losses or expenses
incurred by the Holder or any third party. Specifically excluded from Limited Warranty coverage
are damage to the Units due to ordinary wear and tear, alteration, accident, misuse, abuse or
neglect of the Units; the Units being subjected to vehicle traffic or other conditions which are not
permitted by the installation instructions; failure to maintain the minimum ground covers set forth
in the installation instructions; the placement of improper materials into the system containing the
Units; failure of the Units or the septic system due to improper siting or improper sizing, excessive
water usage, improper grease disposal, or improper operation; or any other event not caused by
Infiltrator. This Limited Warranty shall be void if the Holder fails to comply with all of the terms set
forth in this Limited Warranty. Further, in no event shall Infiltrator be responsible for any loss or
damage to the Holder, the Units, or any third party resulting from installation or shipment, or from
any product liability claims of Holder or any third party. For this Limited Warranty to apply, the
Units must be installed in accordance with all site conditions required by state and local codes; all
other applicable laws; and Infiltrator’s installation instructions.
(d) No representative of Infiltrator has the authority to change or extend this Limited Warranty. No
warranty applies to any party other than the original Holder. The above represents the Standard
Limited Warranty offered by Infiltrator. A limited number of states and counties have different war-
ranty requirements. Any purchaser of Units should contact Infiltrator’s Corporate Headquarters in
Old Saybrook, Connecticut, prior to such purchase, to obtain a copy of the applicable warranty,
and should carefully read that warranty prior to the purchase of Units.
Quick4 Plus Standard Low Profile Chamber ________________________________________________________________________
Quick4 Plus All-in-One 8 Endcap ________________________
Quick4 Plus All-in-One Periscope ________________________
6"
5"9"
(EFFECTIVE LENGTH)
48"34"
8"
8"
4.5"
EFFECTIVE
LENGTH*
6"
18"
8"
3.3"
INVERT
13.3”
EFFECTIVE
LENGTH*
When installed
at the end
of a trench.
10.4"
EFFECTIVE
LENGTH*
When installed
between
2 chambers.INVERT
9.6"
18"
3.3"
INVERT
Quick4 Plus Endcap ____________________________________
(EFFECTIVE LENGTH)48"34"8"
8"
4.5"
EFFECTIVE
LENGTH*
6"
18"
8"
3.3"
INVERT
13.3”
EFFECTIVE
LENGTH*
When installed
at the end
of a trench.
10.4"
EFFECTIVE
LENGTH*
When installed
between
2 chambers.INVERT
9.6"
18"
3.3"
INVERT
(EFFECTIVE LENGTH)48"34"8"
8"
4.5"
EFFECTIVE
LENGTH*
6"
18"
8"
3.3"
INVERT
13.3”
EFFECTIVE
LENGTH*
When installed
at the end
of a trench.
10.4"
EFFECTIVE
LENGTH*
When installed
between
2 chambers.INVERT
9.6"
18"
3.3"
INVERT
(EFFECTIVE LENGTH)
48"34"
8"
8"
4.5"
EFFECTIVE
LENGTH*
6"
18"
8"
3.3"
INVERT
13.3”
EFFECTIVE
LENGTH*
When installed
at the end
of a trench.
10.4"
EFFECTIVE
LENGTH*
When installed
between
2 chambers.INVERT
9.6"
18"
3.3"
INVERT
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-SF-OS-1
Rev. 1.1, © 09/14
Page 1 of 1
Orifice Shields
Technical Data SheetOrenco®
General
Orenco Orifice Shields snap-fit onto laterals. They may be placed on
top of or beneath a lateral, depending on the location of the orifice.
Orifice shields are covered by method-of-use patent # 5,360,556.
Standard Models
OS075, OS100, OS125, OS150, OS200
Product Code Diagram
Material of Construction
PVC per ASTM D-1784
Physical Specifications
Model Shield O.D. Lateral pipe O.D.
in. (mm) in. (mm)
OS075 3.5 (89) 1.05 (27)
OS100 3.5 (89) 1.315 (33)
OS125 3.5 (89) 1.66 (42)
OS150 4.5 (114) 1.90 (48)
OS200 4.5 (114) 2.375 (60)
Applications
Orenco® Orifice Shields are used in a pressurized distribution system
to protect the orifices from backfill debris that might cause orifice
blockage.
Orifice shield installed on lateral pipe, standard configuration
Shield
Orifice
Cutaway view, standard configuration
Shield
Orifice
Cutaway view, cold weather configuration
OS
Lateral pipe size, nominal:
075 = 0.75 in. (20 mm)
100 = 1.00 in. (25 mm)
125 = 1.25 in. (32 mm)
150 = 1.50 in. (40 mm)
200 = 2.00 in. (50 mm)
Orifice shield
Claire Lewandowski <claire.lewandowski@eaglecounty.us>
95 Blue Creek Trail
4 messages
Danielle Sell <danielle.sell@eaglecounty.us>Mon, Mar 29, 2021 at 2:49 PM
To: Carla Ostberg <carla.ostberg@gmail.com>, richard@allservicespetic.com
Cc: Claire Lewandowski <claire.lewandowski@eaglecounty.us>
Good afternoon,
After reviewing the design and soil study performed for 95 Blue Creek Trail we noticed that it was noted that there was high gravel content in areas around the
foundation but not around the proposed location for the STA. We believe one additional test pit adjacent to the STA should be performed to confirm the gravel
content of the soil in this area. Are you able to do this so that we can move forward with the permit? We could also condition this in the permit to be performed at
the time of installation. We would like to be notified at this time to observe the test pit and soil content. Let me know your thoughts.
--
Danielle Sell, M.S.
Environmental Health Specialist I
Eagle County Public Health and Environment
Office: (970) 328-8755
Direct: (970) 471-6481
danielle.sell@eaglecounty.us
For the most recent COVID-19 information please visit www.eaglecountycovid.org.
Carla Ostberg <carla.ostberg@gmail.com>Mon, Mar 29, 2021 at 3:01 PM
To: Danielle Sell <danielle.sell@eaglecounty.us>
Cc: richard@allservicespetic.com, Claire Lewandowski <claire.lewandowski@eaglecounty.us>
I will get with Oli, the architect, to see if they have some equipment on site.
thanks!
Carla Ostberg
CBO Septic Consulting
970.309.5259
Office
981 Cowen Drive, B-7
Carbondale, CO 81623
Mailing
33 Four Wheel Drive Road
Carbondale, CO 81623
[Quoted text hidden]
Carla Ostberg <carla.ostberg@gmail.com>Wed, Mar 31, 2021 at 10:04 AM
To: Danielle Sell <danielle.sell@eaglecounty.us>, Richard Petz <patrich2us@yahoo.com>, Oli Johannsson <ojohannsson@comcast.net>
Cc: Claire Lewandowski <claire.lewandowski@eaglecounty.us>
Hi Everyone,
We did soils for this property some time ago, although I do remember it well as we were pleasantly surprised that the "soils" were better farther south vs the area
of the foundation was nothing but rock. We did the soil testing with CTL Thompson.
At the time of the original soil test, the rock content section of the regs was not broken out like it is now (although I updated the design more recently). The
challenge of "rock content" for soil in Missouri Heights continues as the calcareous clay matrix is somewhat unique to our area.
That said, there is no machine on site at this time. We are wondering if the permit could be issued with a contingency to further explore the area of the proposed
STA with additional test pits prior to construction of the OWTS. If we were to find consistency with my original findings, the design as documented will work fine.
If we are to find higher rock content in additional pits, we could change the design to bring in 2-3 feet of sand filter material to be placed under the chambers or
other distribution media with the design remaining generally the same size and configuration.
Currently, I have specified 3 beds, each with 2 rows of 10 Q4 chambers for a total of 60 chambers and 720 SQ of infiltrative area. If we simply over-excavated
and placed sand filter material, our LTAR would move from 0.6 gal/SF to 0.8 gal/SF (525 GPD/0.8 = min. 657 SF). We could keep the same 3 beds and would
meet the minimum square footage in the same footprint. If the design were to change to a sand filter, I may opt for a different distribution technology than
chambers, but we could address that with a revised design, should that be necessary.
Let us know your thoughts. Thank you!
Carla Ostberg
CBO Septic Consulting
970.309.5259
Office
981 Cowen Drive, B-7
Carbondale, CO 81623
Mailing
33 Four Wheel Drive Road
Carbondale, CO 81623
On Mon, Mar 29, 2021 at 2:50 PM Danielle Sell <danielle.sell@eaglecounty.us> wrote:
[Quoted text hidden]
C1308 OWTS Design Packet 11 29 20.pdf
5934K
Claire Lewandowski <claire.lewandowski@eaglecounty.us>Wed, Mar 31, 2021 at 10:19 AM
To: Carla Ostberg <carla.ostberg@gmail.com>
Cc: Danielle Sell <danielle.sell@eaglecounty.us>, Richard Petz <patrich2us@yahoo.com>, Oli Johannsson <ojohannsson@comcast.net>
That sounds like a good plan. Danielle can condition that in the permit and we will get it sent out.
Thanks!~
[Quoted text hidden]
--
Claire Lewandowski, REHS
Environmental Health Specialist III
970-328-8755 (office)
970-328-8747 (direct)
environment@eaglecounty.us
www.eaglecounty.us
For current information on COVID19 in Eagle County, please visit http://eaglecountycovid.org/
or call 970-328-9750
Environmental Health Department
500 Broadway | PO Box 179
Eagle, CO 81631
970-328-8755
_____________________________________________________________________________
NOTICE OF VIOLATION
_____________________________________________________________________________
IN THE MATTER OF:
Business Name: Skyline Excavation
Business Owner: Jose Manuel Landa (Manny Landa)
Mailing Address: 5033 CountyRroad 335, #124, New castle, CO, 81647, US
mannylanda1014@gmail.com
_____________________________________________________________________________
October 21, 2022
RE: NOTICE OF VIOLATION: OPERATING WITHOUT EAGLE COUNTY SYSTEMS
INSTALLER LICENSE
Dear Manuel Landa:
This letter is Official Notice that Manuel Landa/Skyline Excavation is in violation of Eagle County
Onsite Wastewater Treatment System (OWTS) Regulations, effective August, 2018:
1. Section 5.2.A. and Colorado Revised Statutes (C.R.S.) Section 25-10-109, which states that
“No person may engage in business as a systems installer without possessing a valid Eagle
County systems cleaner license.”
2. Any person who commits any of the following acts or violates any of the provisions of this
section has committed a Class 1 petty offense, as defined in C.R.S. §18-1.3-503: Conducts a
business as a systems cleaner without having obtained the license provided for in C.R.S. §25-
10-109(2), in areas which the Board has adopted licensing regulations pursuant to that
section. Upon a finding by the Board that a person is in violation of this regulation, the Board
may assess a penalty of up to $50 for each day of violation.
An OWTS was Installed at 95 Blue Creek Trail by Skyline Excavation and Manuel Landa without first
obtaining a 2022 Eagle County OWTS Installers license
Upon receipt of this notice, you have 2 business days to contact us and determine timeline for
compliance of these requirements. If contact by the business owner, or requirements of the NOV
are not fulfilled within the required time outlined, we shall begin the Administrative Hearing
process.
Your cooperation is greatly appreciated. If you have any questions, please contact 970-328-8755
1
or e-mail environment@eaglecounty.us. For additional information, you may also refer to
www.septicsmart.org
Sincerely,
, REHS Claire Lewandowski
Environmental Health Specialist III
EAGLE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT:
______________________________
Morgan Hill
Environmental Health Manager
Cc: Heath Harmon, Public Health Director
Assistant County Attorney
File
Claire Lewandowski <claire.lewandowski@eaglecounty.us>
95 Blue Creek Trail
2 messages
Carla Ostberg <carla.ostberg@gmail.com>Wed, Oct 19, 2022 at 10:54 AM
To: Claire Lewandowski <claire.lewandowski@eaglecounty.us>, Brent Ritter <britter@hansenconst.com>, Manuel Landa
<mannylanda1014@gmail.com>
Claire, Manny, and Brent,
I'm sorry that we are having to take steps backward on this.
Just to recap, I originally was onsite to do the soil investigation on July 28, 2017. The test pit close to the house was
extremely rocky, but farther south we got down to 6-feet, with soils the typical "calcareous clay matrix" which is the white
to tan, fine grained soils. The design choice for this, as with many of the systems I design in Missouri Heights, is to just
scrape the topsoil and get on top of that calcareous clay matrix horizon because once you get into that horizon, that's
where the big Basalt boulders live and they can be all sizes, including sizes that can't be moved or dug out.
I guess we just got "lucky" with our test pit and it wasn't representative enough of overall soils onsite.
Classifying soils as R-1, we need to import 2' min of sand filter material (it's WASHED SAND from WSM, similar to
concrete sand). With this change, we can size on 0.8 gal/SF and the required area is 656.5SF. The current design is
720SF, so we have sufficient SF to meet code requirements.
The footprints will be excavated to the extent possible, placing sand in the excavation and placing the chambers and
distribution laterals on top of the sand. Mounding will be necessary and soil should be imported to cover and regrade
over the beds.
The only other thing we need to verify is the easement to the west to assure we are not encroaching with the change in
the field location.
Please let me know if you have any questions!
Carla Ostberg
CBO Septic Consulting
970.309.5259
Office
981 Cowen Drive, B-7
Carbondale, CO 81623
Mailing
129 Cains Lane
Carbondale, CO 81623
Manuel Landa <mannylanda1014@gmail.com>Wed, Oct 19, 2022 at 9:04 PM
To: Carla Ostberg <carla.ostberg@gmail.com>
Cc: Brent Ritter <britter@hansenconst.com>, Claire Lewandowski <claire.lewandowski@eaglecounty.us>
Got it.
[Quoted text hidden]