Permit
Permit No. OWTS-020811-2021
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 4/1/2021 Expires: 7/30/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
390 PASEO, EL JEBEL AREA,239127304004
Owner Information Address
Ryan Watts Phone:
Cell: (970) 439-8746
Email: rywatts@hotmail.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Hagist Excavation, LLC tim@hagistx.com(970) 379-9726OWTSPL-000112-20
20
Permitted Construction / Details:
Install the new system exactly as depicted in the CBO Septic Consulting design dated March 7th, 2021, stamped and
signed March 20th, 2021 by Romeo Baylosis P.E. The new system will be sized to accommodate the maximum daily
flows for a 3 bedroom residence with the possibility of an additional bedroom in the future.
Two 8 foot deep test pits must be excavated prior to the installation of the STA to verify the soil types present. Eagle
County Environmental Health should be contacted at this time to verify this.
This OWTS consists of one sewer line from the residence foundation. An Infiltrator 1,500 gallon, 2-compartment poly
septic tank and an Infiltrator 500 gallon, single compartment poly pump chamber shall be used in series. The pump
and the Biotube ProPak Pump Package will be present in the 500 gallon tank. An Orenco PF3005 pump will be used.
The floats will be set to dose 70 gallons each pump cycle. An ADV located at the high point of the system, made
accessible at grade, will alternate doses between two sets of distribution laterals to a 3 feet unlined sand filter bed
that measures 7' by 47'. Inspection ports should be present at each corner of the bed. Gradation analysis must
confirm that sand is secondary sand media.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system or certifying occupancy.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Sell
Date
April 01, 2021
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Thursday, April 1, 2021 1
INSPECTION WORKSHEET (EL JEBEL AREA - 390 PASEO - 514060)
FOR EAGLE COUNTY GOVERNMENT
OWTS-020811-2021Case Number:Case Module:Permit Management
04/20/2022 ApprovedInspection Status:Inspection Date:
OWTS Final InspectionInspection Type:Inspector:
Job Address:Parcel Number:390 Paseo
El Jebel Area, CO
239127304004
Company Name NameContact Type
Contractor El Jebel Concrete LLC Jim Marshall
Engineer RB Civil LLC Romeo Baylosis
Engineer Consultant CBO Septic Consulting Carla Ostberg
Owner Ryan Watts
CommentsPassedChecklist Item
True A 1500-gallon, two-compartment Norwesco® poly septic tank
followed by a pump chamber with an Orenco® Biotube Pump
Vault and an Orenco PF5005 pump was used. The pump
chamber was constructed of two 4-foot diameter concrete
manways joined with butyl rubber sealant.
Septic Tank - Septic Tank
True Received 4/14/2022 from CBO Inc.Record Drawing - Record Drawing
True Received 4/14/2022 from CBO Inc.Record Photos - Record Photos
True Received 5/14/2021 from CBO Inc.Site and Soil - Site & Soil
True Received 4/14/2022 from CBO Inc.Final Certification Letter - Final Certification Letter
True Received 5/14/2021 from CBO Inc.General Plan - General Plan
True The STA consisted of two 7' x 47' over excavated beds with a 3 foot
sand filter. An ADV was placed at the high point of the system. Two
39" wide GeoMats were placed on the 7 foot wide beds.
Soil Treatment Area (STA) - Soil Treatment Area (STA)
True El Jebel Concrete and Excavation was the licensed installer.Identification of Systems Contractor - Identification of
Systems Contractor
April 20, 2022 Page 1 of 1P.O. Box 179, 500 Broadway, Eagle, CO 81631-0179
CBO Inc.
129 Cains Lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
April 12, 2022 Project No. C1591
Ryan Watts & Kayla Kawalick
Rywatts@hotmail.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
390 Paseo
Eagle County, Colorado
Permit Number OWTS-4-1-2021
Ryan and Kayla,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on August 21 and
April 12, 2022 for the subject property. Jim Marshall with El Jebel Concrete and Excavation installed the
system.
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD was used.
The system installation included a 1500-gallon, two-compartment Norwesco® poly septic tank followed
by a pump chamber with an Orenco® Biotube Pump Vault and an Orenco® PF5005 pump. Due to a
shortage of materials during the time the system was installed, the pump chamber was constructed of two 4-
foot diameter concrete manways joined with butyl rubber sealant. A water test was performed on the pump
chamber to assure it was water-tight. The floats were set to dose approximately 70 gallons each pump
cycle, allowing approximately 1.5 gallons of drain back. The control panel for the pump was located within
line of sight of the septic tank. Valley Precast out of Buena Vista performed start-up of the pumping system
on February 17, 2022.
Effluent is pumped through a 1.5-inch diameter pump line from the pump chamber to an Orenco®
automatic distributing valve (ADV), model 6402. The ADV was placed at a high point in the system in an
insulated riser with access from grade.
Effluent is pressure dosed to through 1.5-inch diameter distribution lines to two 7’ x 47’ beds. A minimum of
3-feet of sand filter material was installed in the over-excavated footprints. There was at least 6-feet of
undisturbed soil between each sand filter. A gradation of the sand media is enclosed.
Laterals were 1.5-inches in diameter with 5/32-inch diameter orifices facing down, spaced 2.5-feet on center,
installed on the GeoMat™ with the filter fabric over the laterals. Laterals were placed 2-feet from the edges
of the bed with 3.0-feet between the laterals. Two 39” wide GeoMat™ were placed on the 7-foot wide beds.
Each 1.5-inch diameter lateral ends in a sweeping ell facing up with a ball valve for flushing. Valves were
placed in 10-inch sprinkler boxes for access. Laterals were covered by a soil separation fabric and at least
1-foot of topsoil or other suitable soil able to support vegetative growth. Inspection ports were placed at
each corner of each bed. Ports were cut to grade and covered with a valve box for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
4-14-2022
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent on the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS Romeo Baylosis, P.E.
Layout of GeoMat™ on sand filter media with laterals, orifice shields, and flushing valves at the end of
each lateral
View of septic tank lids View of pump chamber Septic tank
Pump chamber / water test / butyl sealant
Manifold connecting laterals on each bed Over-excavation prior to placement of sand
Stub out in foundation for sewer line
Looking south toward pump chamber Looking from ADV toward STA
Pump chamber ADV
Inlet side of tank Effluent filter
Pump Selection for a Pressurized System - Single Family Residence Project
Parameters
Discharge Assembly Size
Transport Length Before Valve
Transport Pipe Class
Transport Line Size
Distributing Valve Model
Transport Length After Valve
Transport Pipe Class
Transport Pipe Size
Max Elevation Lift
Manifold Length
Manifold Pipe Class
Manifold Pipe Size
Number of Laterals per Cell
Lateral Length
Lateral Pipe Class
Lateral Pipe Size
Orifice Size
Orifice Spacing
Residual Head
Flow Meter
'Add-on' Friction Losses
1.25
13
40
1.50
6402
33
40
1.50
2
3
40
1.50
4
45
40
1.50
5/32
2.5
5
None
0
inches
feet
inches
feet
inches
feet
feet
inches
feet
inches
inches
feet
feet
inches
feet
Calculations
Minimum Flow Rate per Orifice
Number of Orifices per Zone
Total Flow Rate per Zone
Number of Laterals per Zone
% Flow Differential 1st/Last Orifice
Transport Velocity Before Valve
Transport Velocity After Valve
0.68
38
25.8
2
1.7
4.1
4.1
gpm
gpm
%
fps
fps
Frictional Head Losses
Loss through Discharge
Loss in Transport Before Valve
Loss through Valve
Loss in Transport after Valve
Loss in Manifold
Loss in Laterals
Loss through Flowmeter
'Add-on' Friction Losses
4.7
0.5
5.8
1.3
0.0
0.2
0.0
0.0
feet
feet
feet
feet
feet
feet
feet
feet
Pipe Volumes
Vol of Transport Line Before Valve
Vol of Transport Line After Valve
Vol of Manifold
Vol of Laterals per Zone
Total Vol Before Valve
Total Vol After Valve
1.4
3.5
0.3
9.5
1.4
13.3
gals
gals
gals
gals
gals
gals
25.8
19.5
gpm
feet
0 1020304050607080
0
20
40
60
80
100
120
140
160
Net Discharge (gpm)
PumpData
PF5005 High Head Effluent Pump
50 GPM, 1/2HP
115/230V 1Ø 60Hz, 200/230V 3Ø 60Hz
PF5007 High Head Effluent Pump
50 GPM, 3/4HP
230V 1Ø 60Hz, 200/230/460V 3Ø 60Hz
PF5010 High Head Effluent Pump
50 GPM, 1HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF5015 High Head Effluent Pump
50 GPM, 1-1/2HP
230V 1Ø 60Hz, 200V 3Ø 60Hz
Legend
System Curve:
Pump Curve:
Pump Optimal Range:
Operating Point:
Design Point:
February 17, 2022
To Whom It May Concern:
We have been to the following site(s):
390 Paseo Dr, El Jebel
Pump startup was completed.
We have verified that the system was started properly. The System went through several
cycles with no issues.
Sincerely,
Travis Nall
Service Manager
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-020811-2021
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 4/1/2021 Expires: 7/30/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
390 PASEO, EL JEBEL AREA,239127304004
Owner Information Address
Ryan Watts Phone:
Cell: (970) 439-8746
Email: rywatts@hotmail.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Hagist Excavation, LLC tim@hagistx.com(970) 379-9726OWTSPL-000112-20
20
Permitted Construction / Details:
Install the new system exactly as depicted in the CBO Septic Consulting design dated March 7th, 2021, stamped and
signed March 20th, 2021 by Romeo Baylosis P.E. The new system will be sized to accommodate the maximum daily
flows for a 3 bedroom residence with the possibility of an additional bedroom in the future.
Two 8 foot deep test pits must be excavated prior to the installation of the STA to verify the soil types present. Eagle
County Environmental Health should be contacted at this time to verify this.
This OWTS consists of one sewer line from the residence foundation. An Infiltrator 1,500 gallon, 2-compartment poly
septic tank and an Infiltrator 500 gallon, single compartment poly pump chamber shall be used in series. The pump
and the Biotube ProPak Pump Package will be present in the 500 gallon tank. An Orenco PF3005 pump will be used.
The floats will be set to dose 70 gallons each pump cycle. An ADV located at the high point of the system, made
accessible at grade, will alternate doses between two sets of distribution laterals to a 3 feet unlined sand filter bed
that measures 7' by 47'. Inspection ports should be present at each corner of the bed. Gradation analysis must
confirm that sand is secondary sand media.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system or certifying occupancy.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Sell
Date
April 01, 2021
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Thursday, April 1, 2021 1
832‐R‐13‐002
33 Four Wheel Drive Road
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
March 7, 2021 Project No. C1591
Ryan Watts & Kayla Kawalick
Rywatts@hotmail.com
Onsite Wastewater Treatment System Design
3-Bedroom Residence + 1 Future Bedroom
390 Paseo
Eagle County, Colorado
Ryan and Kayla,
CBO Inc. has completed an onsite wastewater treatment system (OWTS) design for the subject
residence. The property is located outside of Basalt, in an area where OWTSs are necessary.
Legal Description: Subdivision: ASPEN MESA ESTATES FIL 1 Lot: 52
Parcel ID: 2391-273-04-004
SITE CONDITIONS The property is currently undeveloped. A 3-bedroom residence is proposed with a future bedroom
contemplated.
The residence will be served by a community water system. The water line will enter the property from
the north and no OWTS component will come within 25-feet of the water line.
The proposed soil treatment area (STA) will be located south of the residence. The area is densely
vegetated with scrub oak. The area slopes to the southeast at an approximate 20-22% slope.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
prior to construction of the STA.
SUBSURFACE American GeoServices made recommendations regarding the proposed OWTS in a septic feasibility report
dated July 31, 2020, Project No. 0326-WS20 (enclosed). The report classified soils as Silty Sand Silt to Silty
Clayey Sand with more than 35% gravel/rock, concluding soils should be classified as R-0 for design
purposes.
Two Borings were drilled to a maximum depth explored of 5.0-feet. No groundwater was encountered at the
time of drilling.
The materials encountered in Boring #1 consisted of sand to silty sand with gravel and cobbles, medium to
fine grain, brown, dry to damp, medium dense to dense (colluvium) to 1.25-feet, underlain by sandy
clayey to silty clayey and weathered rock fragments, brown to gray brown, medium dense to dense, low
plasticity (colluvium) to a maximum depth explored of 5.0-feet.
Page 2
The materials encountered in Boring #2 consisted of sandy clayey to silty clayey and weathered rock
fragments, brown to gray brown, medium dense to dense, low plasticity (colluvium) to a maximum depth
explored of 5.0-feet.
STA sizing is recommended as R-0 with a proposed over-excavated sand filter with a minimum of 3-feet
sand filter material (Secondary Sand). A long term acceptance rate (LTAR) of 0.8 gallons per square
foot will be used to design the OWTS.
No open profile pits were excavated in the scope of work outlined in this report. Soil profile test pits to
must be excavated with a track hoe to verify soils prior to construction of the OWTS. Access to
the location of the proposed STA is made difficult because of a steep slope off the county road to the
south and dense vegetation on the property. When the driveway is constructed, it will be feasible to bring
in a track hoe for access to the proposed STA and removal of trees. We must be present to evaluate
soils in the soil profile test pits when excavated. If soils are different than described by American
GeoServices, we may propose a change to the OWTS design; however, in our experience with soils in
this area, findings in the American GeoServices report are consistent with soils typically encountered in
this area.
DESIGN SPECIFICATIONS
Design Calculations:
Average Design Flow = 75 gallons/person/day (GPD) x 2 people/bedroom x 3 Bedrooms + 75 GPD (4th
bedroom) = 525 GPD
LTAR = 0.8 GPD/SF
525 GPD / 0.8 GPD/SF = 657 SF
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD will be used.
For the purposes of this OWTS design, Benchmark Elevation at grade 7166’ (Lower Level Finished
Floor) has been established as 100’. The sewer line will exit the foundation at approximately 7164’ (98’).
CBO Inc. should be notified of any discrepancies or problems with grade elevations of proposed
components during installation of the OWTS.
OWTS Component Minimum Elevation
Primary Tank Inlet Invert Approximate horizontal distance 37’ / min. 2% fall
to septic tank / min. 9.25” fall
Automatic Distributing Valve Approximate horizontal distance 13’ / min. 1% rise
for drain back / min. 1.625” rise
Infiltrative Surface Approximate horizontal distance to farthest bed 33’
/ min. 1% fall / min. 4.125” fall to farthest bed
*Elevations are based upon standard OWTS installation practices. Component elevations may change during
installation due to site conditions.
The system installation will include a 1500-gallon, two-compartment Infiltrator® poly septic tank followed
by a 500-gallon Infiltrator® poly pump chamber with an Orenco® Biotube Pump Vault and an Orenco®
PF3005 pump. The floats should be set to dose approximately 70 gallons each pump cycle, allowing
approximately 1.5 gallons of drain back. The control panel for the pump must be located within line of sight
of the septic tank. We recommend Valley Precast out of Buena Vista be contracted for start-up of the
pumping system.
Page 3
Pump Table
Dose Range Max = 133 gal. (525 GPD x 25%
+ 1.5 gal drain back)
Min. 53.5 gal. (13 gal x 4) + 1.5
gal drain back
Dose Setting 70 gallons/dose 1.5 gallons drain back (13’ / 1.5”
diameter pump line)
Float Separation 500 gallon Infiltrator® poly pump
chamber
5.5” on/off float separation
Pump Criteria 25.8 gallons per minute (GPM) 19.5 feet total dynamic head
(TDH)
Effluent will be pumped through a 1.5-inch diameter pump line from the pump chamber to an Orenco®
automatic distributing valve (ADV), model 6402. This pump line must have a minimum 1% grade for proper
drain back into the tank after each pump cycle. The ADV must be placed at a high point in the system and
be placed in an insulated riser with access from grade. Screened rock must be placed below the ADV to
support the ADV and to assure the clear pipes exiting the ADV remain visible for future inspection and
maintenance.
Effluent will be pressure dosed to through 1.5-inch diameter distribution lines to two 7’ x 47’ beds. A
minimum of 3-feet of sand filter material will be installed in the over-excavated footprints. There must be at
least 6-feet of undisturbed soil between each sand filter. Sand filter material must be clean, coarse sand, all
passing a screen having four meshes to the inch. The sand must have an effective size between 0.15 and
0.60 mm. The uniformity coefficient must be 7.0 or less. Material meeting ASTM 33, for concrete sand, with
three percent or less fines passing 200 mesh sieve may be used. A gradation of the sand media must
be submitted to this office prior to obtaining the sand.
Laterals must be 1.5-inches in diameter with 5/32-inch diameter orifices facing down, spaced 2.5-feet on
center, installed on the GeoMat™ with the filter fabric over the laterals. Laterals should be placed 2-feet
from the edges of the bed with 3.0-feet between the laterals. Two 39” wide GeoMat™ must be placed on
the 7-foot wide beds. All material associated with the GeoMat™ installation must be proprietary products
associated with the GeoMat™, including orifice shields and geotextile fabric. Manufacturer instructions must
be followed regarding installation of the GeoMat™.
Each 1.5-inch diameter lateral must end in a sweeping ell facing up with a ball valve for flushing. Valves
should be placed in a 10-inch sprinkler box for access. Laterals must be covered by a soil separation
fabric and at least 1-foot of topsoil or other suitable soil able to support vegetative growth. There shall be no
cobble-sized (<2.5”) or greater rock in final cover over the GeoMat™. Inspection ports must be placed at
each corner of each bed. Ports may be cut to grade and covered with a valve box for access.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
Page 4
COMPONENT MANUFACTURER MODEL NO. COMMENTS
Septic Tank Infiltrator® Item # IM-1530-2CP 1500-gallon, 2-
compartment poly septic
tank
Effluent Filter Orenco® 4-inch diameter, full size
filter and housing
Pump Tank Infiltrator® Item # IM-540-HH 500-gallon, single
compartment poly pump
chamber
Pump Orenco® PF300511 ½ HP
120 Volt
Biotube ProPak Pump Package Orenco® BPP30DD Vault, Filter, Control Panel (demand dose)
Tank Risers and Lids Orenco® Double-walled PVC Risers and Lids (24” diameter)
ADV Orenco® V6402A 1.5” Inlet and Outlets
ADV Riser and Lid Orenco® Double-walled PVC Risers
and Lids (30” diameter) GeoMat™ GeoMatrix Systems, LLC 188’ GeoMat™ (39” sheets)
68 orifice shields Flushing Assembly Orenco® 1.5” diameter (2) 45° or 90° long sweep only (4 total)
Construction must be according to Eagle County On-Site Wastewater Treatment System Regulations, the
OWTS Permit provided by Eagle County Environmental Health Department, and this design.
INSTALLATION CONTRACTOR
CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours
in advance to observe the installation.
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
Page 5
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, CBO Inc. should be notified. All OWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Page 6
3-20-2021
Please call with questions.
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE
Pump Selection for a Pressurized System - Single Family Residence Project
Parameters
Discharge Assembly Size
Transport Length Before Valve
Transport Pipe Class
Transport Line Size
Distributing Valve Model
Transport Length After Valve
Transport Pipe Class
Transport Pipe Size
Max Elevation Lift
Manifold Length
Manifold Pipe Class
Manifold Pipe Size
Number of Laterals per Cell
Lateral Length
Lateral Pipe Class
Lateral Pipe Size
Orifice Size
Orifice Spacing
Residual Head
Flow Meter
'Add-on' Friction Losses
1.25
13
40
1.50
6402
33
40
1.50
2
3
40
1.50
4
45
40
1.50
5/32
2.5
5
None
0
inches
feet
inches
feet
inches
feet
feet
inches
feet
inches
inches
feet
feet
inches
feet
Calculations
Minimum Flow Rate per Orifice
Number of Orifices per Zone
Total Flow Rate per Zone
Number of Laterals per Zone
% Flow Differential 1st/Last Orifice
Transport Velocity Before Valve
Transport Velocity After Valve
0.68
38
25.8
2
1.7
4.1
4.1
gpm
gpm
%
fps
fps
Frictional Head Losses
Loss through Discharge
Loss in Transport Before Valve
Loss through Valve
Loss in Transport after Valve
Loss in Manifold
Loss in Laterals
Loss through Flowmeter
'Add-on' Friction Losses
4.7
0.5
5.8
1.3
0.0
0.2
0.0
0.0
feet
feet
feet
feet
feet
feet
feet
feet
Pipe Volumes
Vol of Transport Line Before Valve
Vol of Transport Line After Valve
Vol of Manifold
Vol of Laterals per Zone
Total Vol Before Valve
Total Vol After Valve
1.4
3.5
0.3
9.5
1.4
13.3
gals
gals
gals
gals
gals
gals
Minimum Pump Requirements
Design Flow Rate
Total Dynamic Head
25.8
19.5
gpm
feet
0 5 10 15 20 25 30 35 400
50
100
150
200
250
300
Net Discharge (gpm)
PumpData
PF3005 High Head Effluent Pump
30 GPM, 1/2HP
115/230V 1Ø 60Hz, 200V 3Ø 60Hz
PF3007 High Head Effluent Pump
30 GPM, 3/4HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF3010 High Head Effluent Pump
30 GPM, 1HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF3015 High Head Effluent Pump
30 GPM, 1-1/2HP
230V 1Ø 60Hz, 200/230/460V 3Ø 60Hz
Legend
System Curve:
Pump Curve:
Pump Optimal Range:
Operating Point:
Design Point:
390 Paseo Legend
390 Paseo
200 ft
N➤➤N
• Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
• Installs in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
• Easy to clean by
simply hosing off
whenever the tank
needs pumping
• Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
• Corrosion-proof
construction, to
ensure long life
• Lifetime warranty
Residential Biotube® Effluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a lifetime warranty. They prevent large solids from leaving
the tank, dramatically improving wastewater quality and extending the life
of residential drainfields.
Standard Features & Benefits
• Alarm available, to
signal the need for
cleaning
• Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
• Custom and
commercial sizes
available
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes’ entire
surface for filtering.
Particles larger than
the Biotube’s mesh
are prevented from
leaving the tank.
Optional
Features &
Benefits
Biotube
Filtering
Process
8-in. (200-mm)
Base Inlet Filter
4-in. (100-mm)
Insert Filter
4-in. (100-mm) Biotube Jr.
(4-in. Biotube cartridge avail-
able separately as Insert Filter)
Orenco’s superior effluent filters resist clogging better than all other brands. Our stan-
dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term
protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at
half the size of our standard model, has more filtering capacity than the full-sized filters
sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter
is ideal. And for low-profile tanks, there’s the Base Inlet Filter.
* Covered by patent numbers 5,492,635 and 4,439,323
4-in. (100-mm) Biotube Effluent Filter
APS-FT-1
Rev. 3.4 © 11/10
Orenco Systems®, Inc.
To Order
Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on
“Distributor Locator.”
Nomenclatures
Riser
wall
Tank wall
Filter housing
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube® filter cartridge
Solid base
4-in. Biotube
Effluent Filter
4-in. Biotube Jr.
4-in. Biotube Filter (standard)
4-in. Biotube Jr. (includes cartridge and housing)
Distributed By:
8-in. Biotube Filter (base inlet model)
4-in. Biotube Filter Insert (cartridge only)
Junior series
FT J0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Blank = 1/8" filtration
P = 1/16" filtration
Insert
FT i0418
Biotube effluent filter series
Filter diameter (inches)
Cartridge height (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
-
For customized options (e.g., NC
indicates North Carolina regions)
-
Blank = 1/8" filtration
P = 1/16" filtration
FT 04
Biotube effluent filter series
Filter diameter (inches)
Housing height: 36" and 44" are standard
Options:
Blank = no options
M = flow modulation plate installed
A = float bracket attached
Cartridge height: 28" and 36" are standard
-
Blank = 1/8" filtration
P = 1/16" filtration
W = fits Type 3034 outlet pipe
S = fits Schedule 40 outlet pipe
FT 2208 14 B
Biotube effluent filter series
Housing height: 22" standard
Cartridge height: 14" standard
Options:
A = float bracket
FS = 2" outlet orifice
FSO = 2" outlet orifice and overflow plate*
Base inlet model
-
Blank = 1/8" filtration
P = 1/16" filtration
Filter diameter (inches)
08 = 8"
* Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 1 of 4
Biotube® ProPak Pump Package™
Technical Data SheetOrenco®
60-Hz Series Pump Packages General
Orenco’s Biotube® ProPak™ is a complete, integrated pump package for
filtering and pumping effluent from septic tanks. And its patented pump
vault technology eliminates the need for separate dosing tanks.
This document provides detailed information on the ProPak pump vault
and filter, 4-in. (100-mm) 60-Hz turbine effluent pump, and control panel.
For more information on other ProPak components, see the following
Orenco technical documents:
• Float Switch Assemblies (NSU-MF-MF-1)
• Discharge Assemblies (NTD-HV-HV-1)
• Splice Boxes (NTD-SB-SB-1)
• External Splice Box (NTD-SB-SB-1)
Applications
The Biotube ProPak is designed to filter and pump effluent to either
gravity or pressurized discharge points. It is intended for use in a septic
tank (one- or two-compartment) and can also be used in a pump tank.
The Biotube ProPak is designed to allow the effluent filter to be removed
for cleaning without the need to remove the pump vault or pump, simpli-
fying servicing.
Complete packages are available for on-demand or timed dosing sys-
tems with flow rates of 20, 30, and 50-gpm (1.3, 1.9, and 3.2 L/sec),
as well as with 50 Hz and 60 Hz power supplies.
Standard Models
BPP20DD, BPP20DD-SX, BPP30TDA, BPP30TDD-SX, BBPP50TDA,
BPP50TDD-SX
Product Code Diagram
Biotube® ProPak™ pump package components.
4-in. (100-mm)
turbine effluent pump
Pump motor
Pump
liquid end
Pump vault
Support pipe
Discharge
assembly
Float collar
Float stem
Floats
Float
bracket
Biotube® filter
cartridge
Vault inlet holes
External splice box
(Optional; internal splice
box comes standard.)
Riser lid
(not included)
Riser (not
included)
Control panel
BPP
Pump flow rate, nominal:
20 = 20 gpm (1.3 L/sec)
30 = 30 gpm (1.9 L/sec)
50 = 50 gpm (3.2 L/sec)
Control panel application:
DD = demand-dosing
TDA = timed-dosing, analog timer
TDD = timed dosing, digital timer, elapsed time
meter & counters
Standard options:
Blank = 57-in. (1448-mm) vault height, internal
splice box, standard discharge assembly
68 = 68-in. (1727-mm) vault height
SX = external splice box
CW = cold weather discharge assembly
DB = drainback discharge assembly
Q = cam lock
MFV = non-mercury float
-
Biotube® ProPak™ pump vault
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 2 of 4
ProPak™ Pump Vault
Materials of Construction
Vault body Polyethylene
Support pipes PVC
Dimensions, in. (mm)
A - Overall vault height 57 (1448) or 68 (1727)
B - Vault diameter 17.3 (439)
C - Inlet hole height 19 (475)
D - Inlet hole diameter (eight holes total) 2 (50)
E - Vault top to support pipe bracket base 3 (76)
F - Vault bottom to filter cartridge base 4 (102)
ProPak™ pump vault (shown with Biotube filter and effluent pump)
Biotube® Filter Cartridge
Materials of Construction
Filter tubes Polyethylene
Cartridge end plates Polyurethane
Handle assembly PVC
Dimensions, in. (mm)
A - Cartridge height 18 (457)
B - Cartridge width 12 (305)
Performance
Biotube® mesh opening 0.125 in. (3 mm)*
Total filter flow area 4.4 ft2 (0.4 m2)
Total filter surface area 14.5 ft2 (1.35 m2)
Maximum flow rate 140 gpm (8.8 L/sec)
*0.062-in. (1.6-mm) filter mesh available
Biotube® filter cartridge (shown with float switch assembly)
AA
D
E
B B
C
E
Technical Data Sheet Orenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 3 of 4
Pump Curves
Pump curves, such as those shown here, can help you determine
the best pump for your system. Pump curves show the relationship
between flow (gpm or L/sec) and pressure (TDH), providing a graphical
representation of a pump’s performance range. Pumps perform best
at their nominal flow rate, measured in gpm or L/sec.
4-in. (100-mm) Turbine Effluent Pumps
Orenco’s 4-in. (100 mm) Turbine Effluent Pumps are constructed of
lightweight, corrosion-resistant stainless steel and engineered plastics;
all are field-serviceable and repairable with common tools. All 60-Hz
PF Series models are CSA certified to the U.S. and Canadian safety
standards for effluent pumps, and meet UL requirements.
Power cords for Orenco’s 4-in. (100-mm) turbine effluent pumps are
Type SOOW 600-V motor cable (suitable for Class 1, Division 1 and 2
applications).
Materials of Construction
Discharge: Stainless steel or glass-filled polypropylene
Discharge bearing: Engineered thermoplastic (PEEK)
Diffusers: Glass-filled PPO
Impellers: Acetal (20-, 30-gmp), Noryl (50-gpm)
Intake screens: Polypropylene
Suction connection: Stainless steel
Drive shaft: 300 series stainless steel
Coupling: Sintered 300 series stainless steel
Shell: 300 series stainless steel
Lubricant: Deionized water and propylene glycol
Specifications
Nom. flow, Length Weight Discharge Impellers
gpm (L/sec) in. (mm) lb (kg) in., nominal 1
20 (1.3) 22.5 (572) 26 (11) 1.25 4
30 (1.9) 21.3 (541) 25 (11) 1.25 3
50 (3.2) 20.3 (516) 27 (12) 2.00 2
Performance
Nom. flow, hp (kW) Design Rated Min liquid
gpm (L/sec) flow amps cycles/day level, in. (mm) 2
20 (1.3) 0.5 (0.37) 12.3 300 18 (457)
30 (1.9) 0.5 (0.37) 11.8 300 20 (508)
50 (3.2) 0.5 (0.37) 12.1 300 24 (610)
1 Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® discharge
hose and valve assemblies. Consult your Orenco Distributor about fittings to connect discharge
assemblies to metric-sized piping.
2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® ProPak™ Pump
Vault.
10 20 30 40 6050 70
0.63 1.26 1.89 2.52 3.793.15 4.42
140
120
100
80
60
40
20
Flow in gallons per minute (gpm)
Flow in liters per second (L/sec)Total dynamic head (TDH) in feetTotal dynamic head (TDH) in metersPF 500511
43
37
30
24
18
12
6
PF 200511
PF 300511
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1
Rev. 1.2, © 08/14
Page 4 of 4
AUTO
OFF
MAN
NN1
Control Panel (Demand Dose)
Orenco’s ProPak™ demand dose control panels are specifically engineered
for the ProPak pump package and are ideal for applications such as
demand dosing from a septic tank into a conventional gravity drainfield.
Materials of Construction
Enclosure UV-resistant fiberglass, UL Type 4X
Hinges Stainless steel
Dimensions, in. (mm)
A - Height 11.5 (290)
B - Width 9.5 (240)
C - Depth 5.4 (135)
Specifications
Panel ratings 120 V, 3/4 hp (0.56 kW), 14 A, single phase, 60 Hz
1. Motor-start contactor 16 FLA, 1 hp (0.75 kW), 60 Hz; 2.5 million cycles
at FLA (10 million at 50% of FLA)
2. Circuit 120 V, 10 A, OFF/ON switch, Single pole breakers
3. Toggle switch Single-pole, double-throw HOA switch, 20 A
4. Audio alarm 95 dB at 24 in. (600 mm), warble-tone sound, UL
Type 4X
5. Audio alarm 120 V, automatic reset, DIN rail mount silence
relay
6. Visual alarm 7/8-in. (22-mm) diameter red lens, “Push-to-silence,”
120 V LED, UL Type 4X
Control Panel (Timed Dose)
Orenco’s ProPak timed dose control panels are specifically engineered for
the ProPak pump package and are ideal for applications such as timed
dosing from a septic tank into a pressurized drainfield or mound. Analog or
digital timers are available.
Materials of Construction
Enclosure UV-resistant fiberglass, UL Type 4X
Hinges Stainless steel
Dimensions, in. (mm)
A - Height 11.5 (290)
B - Width 9.5 (240)
C - Depth 5.4 (135)
Specifications
Panel ratings 120 V, 3/4 hp (0.56 kW), 14 A, single phase, 60 Hz
Dual-mode Programmable for timed- or demand-dosing
(digital timed-dosing panels only)
1a. Analog timer 120 V, repeat cycle from 0.05 seconds to 30
(not shown) hours. Separate variable controls for OFF and
ON time periods
1b. Digital timer 120-V programmable logic unit with built-in LCD
(shown below) screen and programming keys. Provides control
functions and timing for panel operation
2. Motor-start contactor 16 FLA, 1 hp (0.75 kW), 60 Hz; 2.5 million cycles
at FLA (10 million at 50% of FLA)
3. Circuit breakers 120 V, 10 A, OFF/ON switch. Single pole 120 V
4. Toggle Switch Single-pole, double-throw HOA switch, 20 A
5. Audio alarm 95 dB at 24 in. (600 mm), warble-tone sound, UL
Type 4X
6. Visual alarm 7/8-in. (22-mm) diameter red lens, “Push-to-silence”,
120 V LED, UL Type 4X
Control panel, demand-dose Control panel, timed-dose (digital timer model shown)
1b
2
3
4
56
1
2
3
4
5
6
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 1 of 6
PF Series 4-inch (100-mm) Submersible Effluent Pumps
Technical Data SheetOrenco®
Applications
Our 4-inch (100-mm) Submersible Effluent Pumps are designed to
transport screened effluent (with low TSS counts) from septic tanks or
separate dosing tanks. All our pumps are constructed of lightweight,
corrosion-resistant stainless steel and engineered plastics; all are field-
serviceable and repairable with common tools; and all 60-Hz PF Series
models are CSA certified to the U.S. and Canadian safety standards for
effluent pumps, meeting UL requirements.
Orenco’s Effluent Pumps are used in a variety of applications, including
pressurized drainfields, packed bed filters, mounds, aerobic units, effluent
irrigation, effluent sewers, wetlands, lagoons, and more. These pumps
are designed to be used with a Biotube® pump vault or after a secondary
treatment system.
Features/Specifications
To specify this pump for your installation, require the following:
• Minimum 24-hour run-dry capability with no deterioration in pump life
or performance*
• Patented 1⁄8-inch (3-mm) bypass orifice to ensure flow recirculation
for motor cooling and to prevent air bind
• Liquid end repair kits available for better long-term cost of ownership
• TRI-SEAL™ floating impeller design on 10, 15, 20, and 30 gpm
(0.6, 1.0, 1.3, and 1.9 L/sec) models; floating stack design on 50 and
75 gpm (3.2 and 4.7 L/sec) models
• Franklin Electric Super Stainless motor, rated for continuous use and
frequent cycling
• Type SOOW 600-V motor cable
• Five-year warranty on pump or retrofit liquid end from date of manu-
facture against defects in materials or workmanship
* Not applicable for 5-hp (3.73 kW) models
Standard Models
See specifications chart, pages 2-3, for a list of standard pumps. For
a complete list of available pumps, call Orenco.
Product Code Diagram
PF -
Nominal flow, gpm (L/sec):
10 = 10 (0.6) 15 = 15 (1.0)
20 = 20 (1.3) 30 = 30 (1.9)
50 = 50 (3.2) 75 = 75 (4.7)
Pump, PF Series
Frequency:
1 = single-phase 60 Hz
3 = three-phase 60 Hz
5 = single-phase 50 Hz
Voltage, nameplate:
1 = 115* 200 = 200
2 = 230† 4 = 460
Horsepower (kW):
03 = 1⁄3 hp (0.25) 05 = ½ hp (0.37)
07 = ¾ hp (0.56) 10 = 1 hp (0.75)
15 = 1-½ hp (1.11) 20 = 2 hp (1.50)
30 = 3 hp (2.24) 50 = 5 hp (3.73)
Cord length, ft (m):‡
Blank = 10 (3) 20 = 20 (6)
30 = 30 (9) 50 = 50 (15)
* ½-hp (0.37kW) only
†220 volts for 50 Hz pumps
‡Note: 20-foot cords are available only for single-phase pumps through 1-½ hp
Franklin
Super Stainless
Motor
Franklin
Liquid End
Discharge Connection
Bypass Orifice
Suction Connection
LR80980
LR2053896
Powered by
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 2 of 6
Specifications, 60 Hz
Pump Model
PF100511 10 (0.6) 0.50 (0.37) 1 115 120 12.7 12.7 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF100512 10 (0.6) 0.50 (0.37) 1 230 240 6.3 6.3 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF10053200 10 (0.6) 0.50 (0.37) 3 200 208 3.8 3.8 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300
PF100712 4, 5 10 (0.6) 0.75 (0.56) 1 230 240 8.3 8.3 8 1 ¼ in. GFP 25.9 (658) 17 (432) 30 (14) 300
PF10073200 4, 5 10 (0.6) 0.75 (0.56) 3 200 208 5.1 5.2 8 1 ¼ in. GFP 25.4 (645) 17 (432) 31 (14) 300
PF101012 5, 6 10 (0.6) 1.00 (0.75) 1 230 240 9.6 9.6 9 1 ¼ in. GFP 27.9 (709) 18 (457) 33 (15) 100
PF10103200 5, 6 10 (0.6) 1.00 (0.75) 3 200 208 5.5 5.5 9 1 ¼ in. GFP 27.3 (693) 18 (457) 37 (17) 300
PF102012 5, 6, 7, 8 10 (0.6) 2.00 (1.49) 1 230 240 12.1 12.1 18 1 ¼ in. SS 39.5 (1003) 22 (559) 48 (22) 100
PF102032 5, 6, 8 10 (0.6) 2.00 (1.49) 3 230 240 7.5 7.6 18 1 ¼ in. SS 37.9 (963) 20 (508) 44 (20) 300
PF10203200 5, 6, 8 10 (0.6) 2.00 (1.49) 3 200 208 8.7 8.7 18 1 ¼ in. SS 37.9 (963) 20 (508) 44 (20) 300
PF150311 15 (1.0) 0.33 (0.25) 1 115 120 8.7 8.8 3 1 ¼ in. GFP 19.5 (495) 15 (380) 23 (10) 300
PF150312 15 (1.0) 0.33 (0.25) 1 230 240 4.4 4.5 3 1 ¼ in. GFP 19.5 (495) 15 (380) 23 (10) 300
PF200511 20 (1.3) 0.50 (0.37) 1 115 120 12.3 12.5 4 1 ¼ in. GFP 22.3 (566) 18 (457) 25 (11) 300
PF200512 20 (1.3) 0.50 (0.37) 1 230 240 6.4 6.5 4 1 ¼ in. GFP 22.5 (572) 18 (457) 26 (12) 300
PF20053200 20 (1.3) 0.50 (0.37) 3 200 208 3.7 3.8 4 1 ¼ in. GFP 22.3 (566) 18 (457) 26 (12) 300
PF201012 4, 5 20 (1.3) 1.00 (0.75) 1 230 240 10.5 10.5 7 1 ¼ in. GFP 28.4 (721) 20 (508) 33 (15) 100
PF20103200 4, 5 20 (1.3) 1.00 (0.75) 3 200 208 5.8 5.9 7 1 ¼ in. GFP 27.8 (706) 20 (508) 33 (15) 300
PF201512 4, 5 20 (1.3) 1.50 (1.11) 1 230 240 12.4 12.6 9 1 ¼ in. GFP 34.0 (864) 24 (610) 41 (19) 100
PF20153200 4, 5 20 (1.3) 1.50 (1.11) 3 200 208 7.1 7.2 9 1 ¼ in. GFP 30.7 (780) 20 (508) 35 (16) 300
PF300511 30 (1.9) 0.50 (0.37) 1 115 120 11.8 11.8 3 1 ¼ in. GFP 21.3 (541) 20 (508) 28 (13) 300
PF300512 30 (1.9) 0.50 (0.37) 1 230 240 6.2 6.2 3 1 ¼ in. GFP 21.3 (541) 20 (508) 25 (11) 300
PF30053200 30 (1.9) 0.50 (0.37) 3 200 208 3.6 3.6 3 1 ¼ in. GFP 21.3 (541) 20 (508) 25 (11) 300
PF300712 30 (1.9) 0.75 (0.56) 1 230 240 8.5 8.5 5 1 ¼ in. GFP 24.8 (630) 21 (533) 29 (13) 300
PF30073200 30 (1.9) 0.75 (0.56) 3 200 208 4.9 4.9 5 1 ¼ in. GFP 24.6 (625) 21 (533) 30 (14) 300
PF301012 4 30 (1.9) 1.00 (0.75) 1 230 240 10.4 10.4 6 1 ¼ in. GFP 27.0 (686) 22 (559) 32 (15) 100
PF30103200 4 30 (1.9) 1.00 (0.75) 3 200 208 5.8 5.8 6 1 ¼ in. GFP 26.4 (671) 22 (559) 33 (15) 300
PF301512 4, 5 30 (1.9) 1.50 (1.11) 1 230 240 12.6 12.6 8 1 ¼ in. GFP 32.8 (833) 24 (610) 40 (18) 100
PF30153200 4, 5 30 (1.9) 1.50 (1.11) 3 200 208 6.9 6.9 8 1 ¼ in. GFP 29.8 (757) 22 (559) 34 (15) 300
PF301534 4, 5 30 (1.9) 1.50 (1.11) 3 460 480 2.8 2.8 8 1 ¼ in. GFP 29.5 (685) 22 (559) 34 (15) 300
PF302012 5, 6, 7 30 (1.9) 2.00 (1.49) 1 230 240 11.0 11.0 10 1 ¼ in. SS 35.5 (902) 26 (660) 44 (20) 100
PF30203200 5, 6 30 (1.9) 2.00 (1.49) 3 200 208 9.3 9.3 10 1 ¼ in. SS 34.0 (864) 24 (610) 41 (19) 300
PF303012 5, 6, 7, 8 30 (1.9) 3.00 (2.23) 1 230 240 16.8 16.8 14 1 ¼ in. SS 44.5 (1130) 33 (838) 54 (24) 100
PF303032 5, 6, 8 30 (1.9) 3.00 (2.23) 3 230 240 10.0 10.1 14 1 ¼ in. SS 44.3 (1125) 27 (686) 52 (24) 300
PF305012 5, 6, 7, 8 30 (1.9) 5.00 (3.73) 1 230 240 25.6 25.8 23 1 ¼ in. SS 66.5 (1689) 53 (1346) 82 (37) 100
PF305032 5, 6, 8 30 (1.9) 5.00 (3.73) 3 230 240 16.6 16.6 23 1 ¼ in. SS 60.8 (1544) 48 (1219) 66 (30) 300
PF30503200 5, 6, 8 30 (1.9) 5.00 (3.73) 3 200 208 18.7 18.7 23 1 ¼ in. SS 60.8 (1544) 48 (1219) 66 (30) 300
PF500511 50 (3.2) 0.50 (0.37) 1 115 120 12.1 12.1 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300
PF500512 50 (3.2) 0.50 (0.37) 1 230 240 6.2 6.2 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300
PF500532 50 (3.2) 0.50 (0.37) 3 230 240 3.0 3.0 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
PF50053200 50 (3.2) 0.50 (0.37) 3 200 208 3.7 3.7 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
PF500534 50 (3.2) 0.50 (0.37) 3 460 480 1.5 1.5 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300
PF500712 50 (3.2) 0.75 (0.56) 1 230 240 8.5 8.5 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300
PF500732 50 (3.2) 0.75 (0.56) 3 230 240 3.9 3.9 3 2 in. SS 23.7 (602) 25 (635) 32 (15) 300
PF50073200 50 (3.2) 0.75 (0.56) 3 200 208 4.9 4.9 3 2 in. SS 23.1 (587) 26 (660) 32 (15) 300Design gpm (L/sec)Horsepower (kW)PhaseNameplate voltageActual voltageDesign flow ampsMax ampsImpellersDischarge size and material 1Length, in. (mm)Min. liquid level, 2 in. (mm)Weight, 3 lb (kg)Rated cycles/day
Technical Data Sheet Orenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 3 of 6
Specifications, 60 Hz (continued)
Pump Model
PF500734 50 (3.2) 0.75 (0.56) 3 460 480 1.8 1.8 3 2 in. SS 34.8 (884) 25 (635) 31 (14) 300
PF501012 50 (3.2) 1.00 (0.75) 1 230 240 10.1 10.1 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100
PF50103200 50 (3.2) 1.00 (0.75) 3 200 208 5.7 5.7 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300
PF501034 50 (3.2) 1.00 (0.75) 3 460 480 2.2 2.2 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300
PF5015124 50 (3.2) 1.50 (1.11) 1 230 240 12.5 12.6 5 2 in. SS 32.5 (826) 30 (762) 41 (19) 100
PF501532004 50 (3.2) 1.50 (1.11) 3 200 208 7.0 7.0 5 2 in. SS 29.3 (744) 26 (660) 35 (16) 300
PF503012 4, 5, 7, 8 50 (3.2) 3.00 (2.23) 1 230 240 17.7 17.7 8 2 in. SS 43.0 (1092) 37 (940) 55 (25) 100
PF50303200 4, 5, 8 50 (3.2) 3.00 (2.23) 3 200 208 13.1 13.1 8 2 in. SS 43.4 (1102) 30 (762) 55 (25) 300
PF503034 4, 5, 8 50 (3.2) 3.00 (2.23) 3 460 480 5.3 5.3 8 2 in. SS 40.0 (1016) 31 (787) 55 (25) 300
PF505012 5,6,7,8 50 (3.2) 5.00 (3.73) 1 230 240 26.2 26.4 13 2 in. SS 65.4 (1661) 55 (1397) 64 (29) 300
PF505032 5,6,7,8 50 (3.2) 5.00 (3.73) 3 230 240 16.5 16.5 13 2 in. SS 59.3 (1506) 49 (1245) 64 (29) 300
PF751012 75 (4.7) 1.00 (0.75) 1 230 240 9.9 10.0 3 2 in. SS 27.0 (686) 27 (686) 34 (15) 100
PF751512 75 (4.7) 1.50 (1.11) 1 230 240 12.1 12.3 4 2 in. SS 33.4 (848) 30 (762) 44 (20) 100
Specifications, 50 Hz
Pump Model
PF100552 10 (0.6) 0.50 (0.37) 1 220 230 3.9 4.1 6 1 ¼ in. GFP 23.0 (584) 17 (432) 26 (12) 300
PF100752 4, 5 10 (0.6) 0.75 (0.56) 1 220 230 6.2 6.2 9 1 ¼ in. GFP 26.8 (658) 17 (432) 30 (14) 300
PF101552 5, 6 10 (0.6) 1.50 (1.11) 1 220 230 10.5 11.4 18 1 ¼ in. SS 39.5 (1003) 22 (559) 46 (21) 300
PF300552 30 (1.9) 0.50 (0.37) 1 220 230 4.1 4.1 4 1 ¼ in. GFP 22.5 (572) 19 (483) 26 (12) 300
PF300752 30 (1.9) 0.75 (0.56) 1 220 230 6.1 6.1 5 1 ¼ in. GFP 24.8 (630) 19 (483) 29 (13) 300
PF301052 30 (1.9) 1.00 (0.75) 1 220 230 7.4 7.4 7 1 ¼ in. GFP 28.4 (721) 20 (508) 32 (15) 100
PF301552 4, 5 30 (1.9) 1.50 (1.11) 1 220 230 9.3 9.3 8 1 ¼ in. GFP 35.4 (899) 24 (610) 40 (18) 100
PF500552 50 (3.2) 0.50 (0.37) 1 220 230 4.0 4.0 2 2 in. SS 20.3 (516) 25 (635) 29 (13) 300
PF500752 50 (3.2) 0.75 (0.56) 1 220 230 6.3 6.4 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300
PF501052 50 (3.2) 1.00 (0.75) 1 220 230 7.3 7.4 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100
PF501552 50 (3.2) 1.50 (1.11) 1 220 230 9.1 9.1 5 2 in. SS 32.5 (826) 30 (762) 42 (19) 100
PF751052 75 (3.2) 1.00 (0.75) 1 220 230 7.3 7.3 4 2 in. SS 30.0 (762) 27 (686) 34 (15) 100
1 GFP = glass-filled polypropylene; SS = stainless steel. The 1 ¼-in. NPT GFP discharge is 2 7⁄8 in. octagonal across flats; the 1 ¼-in. NPT SS discharge is 2 1⁄8 in. octagonal across flats; and the
2-in. NPT SS discharge is 2 7⁄8 in. hexagonal across flats. Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® discharge hose and valve assemblies. Consult your Orenco
Distributor about fittings to connect hose and valve assemblies to metric-sized piping.
2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® Pump Vault or Universal Flow Inducer. In other applications, minimum liquid level should be top of pump. Consult
Orenco for more information.
3 Weight includes carton and 10-ft (3-m) cord.
4 High-pressure discharge assembly required.
5 Do not use cam-lock option (Q) on discharge assembly.
6 Custom discharge assembly required for these pumps. Contact Orenco.
7 Capacitor pack (sold separately or installed in a custom control panel) required for this pump. Contact Orenco.
8 Torque locks are available for all pumps, and are supplied with 3-hp and 5-hp pumps. Design gpm (L/sec)Horsepower (kW)PhaseNameplate voltageActual voltageDesign flow ampsMax ampsImpellersDischarge size and material 1Length, in. (mm)Min. liquid level, 2 in. (mm)Weight, 3 lb (kg)Rated cycles/day
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 4 of 6
Materials of Construction
Discharge Glass-filled polypropylene or stainless steel
Discharge bearing Engineered thermoplastic (PEEK)
Diffusers Glass-filled PPO (Noryl GFN3)
Impellers Celcon® acetal copolymer on 10-, 20, and 30-gpm models; 50-gpm impellers are Noryl GFN3
Intake screen Polypropylene
Suction connection Stainless steel
Drive shaft 7/16 inch hexagonal stainless steel, 300 series
Coupling Sintered stainless steel, 300 series
Shell Stainless steel, 300 series
Motor Franklin motor exterior constructed of stainless steel. Motor filled with deionized water and propylene glycol for constant lubrication. Hermetically
sealed motor housing ensures moisture-free windings. All thrust absorbed by Kingsbury-type thrust bearing. Rated for continuous duty. Single-
phase motors and 200 and 230 V 3-phase motors equipped with surge arrestors for added security. Single-phase motors through 1.5 hp
(1.11 kW) have built-in thermal overload protection, which trips at 203-221˚ F (95-105˚ C).
Using a Pump Curve
A pump curve helps you determine the best pump for your system. Pump curves show the relationship between flow (gpm or L/sec) and pressure
(total dynamic head, or TDH), providing a graphical representation of a pump’s optimal performance range. Pumps perform best at their nominal
flow rate — the value, measured in gpm, expressed by the first two numerals in an Orenco pump nomenclature. The graphs in this section show
optimal pump operation ranges with a solid line. Flow flow rates outside of these ranges are shown with a dashed line. For the most accurate
pump specification, use Orenco’s PumpSelect™ software.
Pump Curves, 60 Hz Models
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
24 81012141660
800
700
600
500
400
300
200
100 PF1005-FC
w/ ¼" flow
controller
PF10 Series, 60 Hz, 0.5 - 2.0 hp
PF1007
PF1010
PF1020
PF1005
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
36 12 15 18 21 2490
160
140
120
100
80
60
40
20
0
PF1503
PF15 Series, 60 Hz, 0.3 hp
Technical Data Sheet Orenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 5 of 6Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
5102025303540150
400
350
300
250
200
150
100
50
0
PF2005
PF2010
PF2015
PF20 Series, 60 Hz, 0.5 - 1.5 hp
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
510202530354045150
800
900
700
600
500
400
300
200
100
0
PF3005
PF3007
PF3010
PF3015
PF3020
PF3030
PF3050 PF30 Series, 60 Hz, 0.5 - 5.0 hp
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
450
400
350
300
250
200
150
100
50
0 10 02040506070809030
PF5050
PF5030
PF5015
PF5010
PF5007
PF5005
PF50 Series, 60 Hz, 0.5 - 5.0 hp
Total dynamic head (TDH) in feetFlow in gallons per minute (gpm)
10 20 40 50 60 70 80 90 100300
80
90
100
70
60
50
40
30
20
10
0
PF75 Series, 60 Hz, 1.0 - 1.5 hpPF7515
PF7510
60 Hz Models (continued)
Technical Data SheetOrenco®
Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1
Rev. 2.2, © 09/14
Page 6 of 6Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.90.80.70.60.50.40.30.20.10
13119.57.96.34.83.21.6
120
100
80
60
40
20
0
160
180
140
394
328
262
197
131
66
525
459
PF100552
PF100752
PF101552
PF1005-FC
w/ 6mm flow
controller
PF10 Series, 50 Hz, 0.37 - 1.11 kW
Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.8 1.2 1.6 2.0 2.40.40
13 19 25 326.3
60
80
100
120
40
20
0
197
262
328
131
66
PF301552
PF301052
PF300752
PF300552
PF30 Series, 50 Hz, 0.37 - 1.11 kW
Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.5 1.0 2.0 2.5 3.0 3.5 4.0 4.51.50
7.9 16 32 40 48 56 6324
40
45
35
30
25
20
15
10
5
0
131
115
98
82
66
49
33
16
PF501552
PF501052
PF500752
PF500552
PF50 Series, 50 Hz, 0.37 - 1.11 kW
Total dynamic head (TDH) in metersTotal dynamic head (TDH) in feet, nominalFlow in liters per second (L/sec)
Flow in gallons per minute (gpm), nominal
0.6 1.2 2.4 3.0 3.6 4.2 5.44.8 6.01.80
10 19 4838 57 67 76 8629
27
30
24
21
18
15
12
9
6
3
0
89
79
69
59
49
39
30
20
PF751052
PF75 Series, 50 Hz, 0.75 kW
Pump Curves, 50 Hz Models
Introduction
Orenco’s automatic distributing valve assemblies, pressurized with small high-head effluent
pumps, are useful for distributing effluent to multiple zones. These zones can be segments
of sand filter manifolds, drainfields, or other effluent distribution systems. Distributing
valve assemblies can substantially simplify the design and installation of a distribution sys-
tem and reduce installation costs. This is particularly true where a distributing valve assem-
bly is used instead of multiple pumps and/or electrically operated valves. Additionally, a
reduction in long term operation and maintenance costs is realized due to a reduced size
and/or number of pumps. More even distribution can be achieved on sloping sites by zoning
laterals at equal elevations. This eliminates drainback to lower lines and the unequal distrib-
ution of effluent that occurs at the beginning of a cycle.
Valve Operation
The valve itself has only a few moving parts, requires no electricity, and alternates automati-
cally each cycle. Refer to Figure 1 for the following valve operation description. The flow
of the incoming effluent forces the rubber flap disk 1 to seat against the valve bottom 2.
The opening 3 in the rubber flap disk aligns with an opening in the valve bottom to allow
flow to only one valve outlet. The stem 4 houses a stainless steel spring which pushes the
rubber flap disk away from the valve bottom after the flow of effluent stops. The stem acts
as a cam follower and rotates the rubber flap disk as the stem is raised and lowered through
the cam 5. The force from the flow of effluent pushes the stem down through the cam and
the stainless steel spring pushes the stem back up through the cam when the flow of effluent
stops. Each linear motion of the stem allows the rubber flap disk to rotate half the distance
necessary to reach the next outlet. When there is no flow, the rubber flap disk is in the “up”
position and is not seated against the valve bottom.
5
4
3
2
1
Inlet
Outlets
Figure 1:
6000 Series Valve
Orenco Automatic Distributing
Valve Assemblies
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 1 of 6
For Wastewater Effluent Systems
This article may describe design criteria that was in effect at the time the article was written. FOR CURRENT DESIGN
CRITERIA, call Orenco Systems, Inc. at 1-800-348-9843.
The Distributing Valve Assembly
The Orenco Automatic Distributing Valve Assembly combines the distributing valve itself and sever-
al other components to give a complete preassembled unit that is easy to install, monitor, and main-
tain. Figure 2 shows a complete assembly. Because distributing valves with several outlets can be
difficult to line up and glue together in the field, the discharge lines in the assemblies are glued in
place at Orenco. The unions (1) allow removal and maintenance of the valve. The clear PVC pipe
sections (2) give a visual check of which discharge line is being pressurized. The inlet ball valve (3)
allows a quick, simple method to test for proper valve cycling. The ball valve also stops the flow of
effluent in case the pump is activated unexpectedly during maintenance or inspection. Check valves
may be necessary on the discharge lines. Use of check valves is discussed in the valve positioning
section.
Valve Assembly Hydraulics
Liquid flowing through the valve assembly must pass through fairly small openings and make several
changes in direction. Because of this, headlosses through the valve assembly are fairly high. Table 1
gives the headloss equations for several different assemblies and Figure 3 shows the graphical repre-
sentations of these equations. Orenco recommends that high-head turbine pumps be used to pressur-
ize the valve assemblies to ensure enough head is available for proper system operation. High-head
turbine pumps are also recommended because the use of a distributing valve usually requires more
frequent pump cycling. The high-head turbine pumps are designed for high cycling systems and will
outlast conventional effluent pumps by a factor of 10 or more in a high cycling mode. Furthermore,
the high-head turbine pump intake is 12 inches or more above the bottom of the pump and tends to
prevent any settled solids from being pumped into the distribution valve and obstructing its opera-
tion. A minimum flow rate through the distributing valve is required to ensure proper seating of the
rubber flap disk. Minimum flow rates for the various models are given in Table 1.
Figure 2:
Orenco Distributing Valve Assembly (6000 Series Valve)
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 2 of 6
Table 1. Automatic Distributing Valve Assembly Headloss Equations
Model Series Equation Operating Range (gpm)
V4400A HL = 0.085 x Q1.45 10 - 40
V4600A HL = 0.085 x Q1.58 10 - 25
V6400A HL = 0.0045 x Q2 + 3.5 x (1 - e-0.06Q) 15 - 70
V6600A HL = 0.0049 x Q2 + 5.5 x (1 - e-0.1Q) 15 - 70
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 3 of 6
0
5
10
15
20
25
30
35
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
Flow (gpm)Head Loss Through Assembly (ft.)V4600A
V4400A
V6600A
V6400A
The Pumping System
Although the distributing valve was designed for the irrigation industry, it has started to gain fairly
wide acceptance in the effluent pumping industry. However, because of the mechanical movements
of the valve, it is necessary to take steps to prevent solids from reaching the distributing valve that
may impede the operation of the valve. Orenco Biotube®Pump Vaults — when properly sized and
installed — provide the necessary protection to prevent valve malfunction. The Biotube®pump vault
accepts effluent only from the clear zone between a tank’s scum and sludge layers and then filters
this effluent through a very large surface area screen cartridge. Without this protection in effluent
systems, the valve has very little chance of reliable long-term operation.
Figure 3:
Automatic distributing valve assembly headloss curves
Valve Positioning
The physical position of the valve in relation to the pump and the discharge point is very important
for proper valve operation. The most reliable operation occurs when the valve is placed at the high
point in the system and as close to the pump as possible. The transport line between the pump and
valve should be kept full if possible. If the line is empty at the beginning of each cycle, pockets of
air during filling can cause random rotation of the valve. The valve is particularly vulnerable to this
erratic rotation with empty lines that are long and not laid at a constant grade. An ideal valve loca-
tion is shown in Figure 4.
If the final discharge point is more than about 2 feet above the valve and the system does not drain
back into the dosing tank, check valves should be installed on the lines immediately following the
valve and a pressure release hole or line should be installed just prior to the valve. This pressure
release hole or line can go into a return line to the dosing tank or to a “minidrainfield” near the valve.
In order for the valve to rotate reliably, no more than about 2 feet of head should remain against the
valve to allow the rubber flap disk to return to its up position. In many cases, it may take from one
minute to several minutes for the pressure in the valve to be lowered enough for proper rotation to
occur. Special care should be taken when installing systems controlled by programmable timers to
ensure cycling does not occur too rapidly. Figure 5 illustrates a valve assembly using check valves.
Pumping downhill to the valve should be avoided unless the transport line is very short and the ele-
vation between the discharge line out of the tank and the valve is less than about 2 feet. If the valve
is located many feet below the dosing tank, random cycling may occur while the transport line drains
through the valve at the end of the cycle. A pressure sustaining valve located just before the distrib-
uting valve may overcome this problem in some instances.
Dosing Tank
Discharge Laterals
Distributing Valve Assembly
Transport Line
Figure 4:
Ideal valve location
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 4 of 6
System Startup
Refer to the Hydrotek Valve booklet that is provided with the distributing valve assembly for the
sequencing of the valve outlets. The transport line should always be flushed with clean water before
installing the valve. Any sand, gravel, or other foreign objects that may have been in the pipe during
installation can easily become lodged in the distributing valve, causing malfunction.
With the pump running, alternately close and open the ball valve on the distributing valve assembly
to check proper rotation of the valve. (Note: If check valves are used on the lines after the distribut-
ing valve, the pump may need to be turned on and off to allow the pressure to be released from the
valve.) If visual operation of which zone is operating is not possible, watch the clear pipe on each
line for indication of which zone is operating.
Maintenance
Annually check for proper operation by following procedures listed in the Hydrotek Valve booklet
and system startup procedures listed above.
Troubleshooting
1. PROBLEM: Valve does not change or cycle to next zone or outlet
CAUSE: The stem and disk assembly is not rotating when water flow is turned off and then
back on.
SOLUTION 1: Ensure that there is no debris inside the cam. Clean and carefully reinstall the cam.
SOLUTION 2: If fewer than the maximum number of outlets are being used, check the installation
of the cam. Ensure that the stem and disk assembly is not being held down by an
improperly installed cam. Refer to the cam replacement instructions.
h
Check Valves if h>2'-0"
Distributing Valve Assembly
Transport Line
Dosing Tank
Pressure Release
Line if h>2'-0"
Discharge Laterals
Figure 5:
Valve assembly below final discharge point
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 5 of 6
SOLUTION 3: Remove the valve top and check for proper movement of stem and disk assembly.
Check for and remove any debris or foreign objects that may jam or retard the
movement of the disk.
SOLUTION 4: Check for freedom of movement of stem and disk assembly up and down over the
center pin in bottom of valve. Scale deposits may build up on the pin and hold stem
and disk assembly down. Clean pin and again check for freedom of movement.
SOLUTION 5: Be sure that all operating outlets are not capped and that the flow to operating zones
is not restricted in any manner. This would cause pressure to build up in the valve
and lock the stem and disk assembly in the down position.
SOLUTION 6: The backflow of water from uphill lines may be preventing the valve from cycling
properly. This can happen when the valve is placed too far below an elevated line.
If the valve cannot be placed close to the high point of the system, a check valve
should be installed near the valve in the outlet line that runs uphill from the valve
and a drain line installed just prior to the valve to relieve the pressure.
2. PROBLEM: Water comes out of all the valve outlets
CAUSE: Stem and disk assembly not seating properly on valve outlet.
SOLUTION 1: Check for sufficient water flow. A minimum flow rate is required to properly seat
the disk as shown in Table 1.
SOLUTION 2: Remove the valve top and check the inside walls to ensure that nothing is interfering
with the up and down movement of the stem and disk assembly inside the valve.
SOLUTION 3: Make sure that the operating outlets are not capped and that the flow to the operat-
ing zones are not restricted in any manner.
3. PROBLEM: Valve skips outlets or zones
CAUSE: Pumping into an empty transport line — especially downhill — may cause the valve
to skip outlets from pockets of air allowing the rubber flap disk to raise during a
cycle.
SOLUTION 1: Keep the transport line full.
SOLUTION 2: If the line must remain empty between cycles, use a larger diameter transport line
laid at a constant grade to prevent air pockets from forming.
CAUSE: The stem and disk assembly is being advanced past the desired outlet.
SOLUTION 1: Ensure that the correct cam for the desired number of zones is installed and that the
outlet lines are installed to the correct outlet ports of the valve as indicated by the
zone numbers on the top of the cam.
NTP-VA-1
Rev. 1.2, © 11/03
Orenco Systems®, Inc.
Page 6 of 6
Distributing Valves
General
Orenco’s Automatic Distributing Valve Assemblies are
mechanically operated and sequentially redirect the
pump’s flow to multiple zones or cells in a distribution
field. Valve actuation is accomplished by a combination
of pressure and flow. Automatic Distributing Valve
Assemblies allow the use of smaller horsepower pumps
on large sand filters and drainfields. For example, a large
community drainfield requiring 300 gpm can use a six-line
Valve Assembly to reduce the pump flow rate requirement
to only 50 gpm.
Orenco only warrants Automatic Distributing Valves when
used in conjunction with High-Head Effluent Pumps with
Biotube®Pump Vaults to provide pressure and flow
requirements, and to prevent debris from fouling valve
operation. An inlet ball valve and a section of clear pipe
and union for each outlet are provided for a complete
assembly that is easy to maintain and monitor. Ideal
valve location is at the high point in the system. Refer to
Automatic Distributing Valve Assemblies (NTP-VA-1) for
more information.
Standard Models
V4402A, V4403A, V4404A, V4605A, V4606A, V6402A, V6403A,
V6404A, V6605A, V6606A.
Nomenclature
Submittal
Data Sheet
Side View
ball valve
elbow
Top View
coupling
clear pipe
distributing valve
union
Bottom View
elbows
Specifications
Materials of Construction
All Fittings:Sch. 40 PVC per ASTMspecification
Unions:Sch. 80 PVCper ASTMspecification
Ball Valve:Sch. 40 PVCper ASTMspecification
Clear Pipe:Sch. 40 PVCper ASTMspecification
V4XXX Distributing Valves: High-strength noncorrosive ABSpolymer and stainless steel
V6XXX Distributing Valves: High-strength noncorrosive ABSpolymer, stainless steel, and die cast metal
NSU-SF-VA-1
Rev. 3.0, © 4/03
Page 1 of 2
Applications
Automatic Distributing Valve Assemblies are used to pressurize
multiple zone distribution systems including textile filters, sand
filters and drainfields.
V
Indicates assembly
Model series:
44 = 4400 series (2-4 outlets)
46 = 4600 series (5-6 outlets)
64 = 6400 series (2-4 outlets)
66 = 6600 series (5-6 outlets)
Distributing valve
Number of active outlets
A
Distributing Valves (continued)
Flow (gpm)Head Loss Through Assembly (ft.)0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
0
5
10
15
20
25
30
35
V4400A
V6600A
V6400A
V4600A
NSU-SF-VA-1
Rev. 3.0, © 4/03
Page 2 of 2
Model Inlet Size (in.) Outlets Size (in.) Flow range (gpm) Max Head (ft.) Min. Enclosure
V4402A 1.25 1.25 10 - 40 170 VB1217
V4403A 1.25 1.25 10 - 40 170 VB1217
V4404A 1.25 1.25 10 - 40 170 VB1217
V4605A 1.25 1.25 10 - 25 170 RR2418
V4606A 1.25 1.25 10 - 25 170 RR2418
V6402A 1.5 1.5 15 - 100 345 RR2418
V6403A 1.5 1.5 15 - 100 345 RR2418
V6404A 1.5 1.5 15 - 100 345 RR2418
V6605A 1.5 1.5 15 - 100 345 RR2418
V6606A 1.5 1.5 15 - 100 345 RR2418
Item#
SEK- Orenco® Flushing Assemblies
Flushing Assemblies
Orenco® flushing assemblies provide easy
access for lateral maintenance. Flushing
assembly kits include a PVC sweep with ball
valve and a polyethylene valve box enclosure.
Orenco® flushing assemblies are available in the
following sizes:
• 1” diameter
• 1.25” diameter
• 1.5” diameter
• 2" diameter
Valve Boxes
Orenco® valve boxes are used to provide access
to flushing assemblies. Constructed of
polyethylene.
Valve Box, 7-in. diameter round enclosure
Note: Kits include VB7 valve box enclosure.
(719) 395-6764
Fax: (719) 395-3727
28005 County Road 317
P.O. Box 925
Buena Vista, CO 81211
Water &
Wastewater
• Systems
• Products
• Service Website: http://valleyprecast.com/
Email: frontdesk@valleyprecast.com
American
GeoServices
Septic Feasibility Report
2663 Cinnabar Rd
Colorado Springs, CO 80921
Ph: (719) 761 6072
www.americangeoservices.com
sma@americangeoservices.com
Ph: (888) 276 4027
Fx: (877) 471 0369
Mailing:1338 Grand Avenue #306
Glenwood Springs, CO 81601
Ph: (303) 325 3869
GEOTECHNICAL & MATERIALS
ENVIRONMENTAL
STRUCTURAL
CIVIL
ENGINEERING AND SCIENCE
888-276-4027
July 31, 2020
PROJECT NO: 0326-WS20
CLIENTS: Mr. Ryan Watts
Reference: Septic Feasibility Report, 390 Paseo Road, Carbondale, CO 81623
Dear Mr. Watts,
At your request, we have completed the septic feasibility report for the referenced project in
accordance with the American GeoServices, LLC (AGS) proposal. Results of our evaluation and
design recommendations are described below.
Soils profile: Silty sand silt to silty clayey sand with more than 35% gravel/rock. Site is underlain
by rocks on the surface and rocky soil profile as shown in the attached photographs. Therefore,
no matter how many explorations are performed, the soil type will primarily be “R0.” Hence, no
further exploration is necessary at this time.
Groundwater: Not encountered.
Design Soil type: Type R0;
Design Long Term Acceptance Rate (LTAR), Treatment Level 1: Use 0.8 for the required
minimum 3-foot deep unlined sand filter.
Conclusion: Site is suitable for on-site waste treatment as per the most current Fremont County,
CO, On-site Wastewater Treatment System (OWTS) Regulations, provided adequate setbacks
are provided for all the components of OWTS. In our opinion, an engineered system
consisting of a 3-ft deep sand filter and/or a mound system with pressure distribution will
be required.
COLORADO WYOMING OREGON WASHINGTON fLORIDA
Project No: 0326-WS20-SEPTIC
Page No: 2 of 5
SITE INVESTIGATION
In July 2020, a detailed site reconnaissance was performed and two soil explorations were made
in the proposed construction area. It was noted that the entire site was rocky with numerous rock
outcrops or rocky soils conditions as shown in the attached photographs. In addition, we reviewed
following available soils literature and public domain websites on the site area:
• Soil Survey Maps, USDA, SCS
• Geology of Colorado, USGS
• Geologic Maps and Colorado Geologic Survey Maps
• USGS Topographic Map.
• U.S. Geological Survey, Open File Reports
• Local County, GIS
Data obtained from site observations, subsurface exploration, laboratory evaluation, and previous
experience in the area was used to perform engineering analyses. Results of engineering
analyses were then used to reach conclusions and recommendations presented in this report.
SURFACE CONDITIONS
The site is as shown in Figure 1 through Figure 4. There are no existing structures at the site near
the proposed explorations. Based on our review of available USGS topographic map and site
visit, the site is gently to moderately sloping downwards to the west southst with a slope of
approximately 10%-25% in the immediate vicinity of the proposed leach field area. There are no
natural or known cultural features of concern at the site . There is no current or historic land use
at the site that is of concern for the proposed septic system.
Based on the site reconnaissance, in our opinion, there will be surface water run -off and
accumulation if proper stormwater management is not implemented. It is the owner’s
responsibility to make sure all the surface water will be diverted away from the septic field area
so that surface water run-off does not accumulate at or near the proposed septic field.
SUBSURFACE CONDITIONS
Following soil classification and identification is based on commonly accepted methods employed
in the practice of civil and septic engineering. It should be recognized that subsurface conditions
often vary both with depth and laterally between individual boring locations. The following is a
summary of the subsurface conditions encountered at the site:
Project No: 0326-WS20-SEPTIC
Page No: 3 of 5
Depth
(Inches) USCS Classification USDA Soil
Texture
Soil
Type
Structure-
Type
Structure-
Grade
0”-8” Sandy silt with
rootmass (Topsoil)
8”-15”
Silty sand to sandy silt
with gravel and rock
fragments (SM/GM)
ROCKY (Gravelly
Sandy to silty
gravel and rock
fragments)
R0 Granular and
blocky Structureless
15”-96”
Silty sandy clayey
gravel with rock
fragments >35% rocks
> 20mm size
(GC/GM)
ROCKY (Gravelly
Sandy to silty
gravel and rock
fragments)
R0 Granular and
blocky Structureless
Groundwater table was not encountered.
Type “R” soils are present throughout. Rocky surface is present. Rock outcrops are
present.
GROUNDWATER
Groundwater table or perched groundwater was not encountered during explorations, and based
on our local experience, groundwater is not anticipated to be present. This observation may not
be indicative of other times or at locations other than the site. Some variations in the groundwater
level may be experienced in the future. Seasonal perched groundwater conditions may be
encountered at higher depths during rainy season. The magnitude of the variation will largely
depend upon the duration and intensity of precipitation, temperature and the surface and
subsurface drainage characteristics of the surrounding area.
CONCLUSIONS and RECOMMENDATIONS
Based upon the results of our On-site Wastewater Treatment System (OWTS) feasibility study, in
our opinion, the site is suitable for OWTS to be designed and constructed in accordance with
current local county OWTS regulations and Colorado Department of Health guidelines, provided
following recommendations are followed:
• Adequate stormwater management should be designed and implemented because there will
be surface water run-off and accumulation if proper stormwater management is not
implemented. It is the owner’s responsibility to make sure all the surface water will be diverted
Project No: 0326-WS20-SEPTIC
Page No: 4 of 5
away from the septic field area so that surface water run-off does not accumulate at or near
the proposed septic field.
• Depending upon the site grading, proposed house location, number of bedrooms, and the
proposed soil treatment area (STA) or leach field or drain field location, a properly designed
septic system along with proper setbacks should be used to satisfy local and state regulations.
• The STA or leach field or drain field can be located on site without encroaching easements,
flood plain, any lake, or any wetlands.
• More than six bedrooms should not be planned.
• We recommend that AGS services are retained to design the septic system in accordance
with the most current local County OWTS regulations.
Above recommendation may be modified based on further investigation and analyses.
LIMITATIONS
Design Data/Recommendations contained in this report are based on our field observations and
subsurface explorations, limited site evaluation, and our present knowledge of the proposed
construction as described by you. It is possible that soil conditions could vary between or beyond
the points explored. If soil conditions are encountered during construction that differ from those
described herein, we should be notified so that we can review and make any supplemental
recommendations necessary. If the scope of the proposed construction, including the proposed
use, number of occupants, or structural locations changes from that described in this report, our
recommendations should also be reviewed and revised by AGS.
Our scope of work did not include any investigation or evaluation of any kind related to any water
bodies, flood hazard evaluation, wetlands evaluation and mitigation, and any evaluation of any
kind related to floods, creeks, hydrology, wetlands, and stormwater management. Our Scope of
Work for this project did not include research, testing, or assessment relative to past or present
contamination of the site by any source. If such contamination were present, it is very likely that
the exploration and testing conducted for this report would not reveal its existence. If the Owner
is concerned about the potential for such contamination, additional studies should be undertaken.
We are available to discuss the scope of such studies with you. No tests were performed to detect
the existence of mold or other environmental hazards as it was beyond Scope of Work.
Local regulations regarding land or facility use, on and off-site conditions, or other factors may
change over time, and additional work may be required with the passage of time. Based on the
intended use of the report within one year from the date of
Project No: 0326-WS20-SEPTIC
Page No: 5 of 5
report preparation, AGS may recommend additional work and report updates. Non -compliance
with any of these requirements by the client or anyone else will release AGS from any liability
resulting from the use of this report by any unauthorized party. Client agrees to defend, indemnify,
and hold harmless AGS from any claim or liability associated with such unauthorized use or non-
compliance.
In this report, we have presented judgments based partly on our understanding of the proposed
construction and partly on the data we have obtained. This report meets professional standards
expected for reports of this type in this area. Our company is not responsible for the conclusions,
opinions or recommendations made by others based on the data we have presented.
This report has been prepared exclusively for the client, its’ engineers and subcontractors for the
purpose of design and construction of the proposed structure. No other engineer, consultant, or
contractor shall be entitled to rely on information, conclusions or recommendations presented in
this document without the prior written approval of AGS.
We appreciate the opportunity to be of service to you on this project. If we can provide additional
assistance or observation and testing services during design and construction phases, please call
us at 1 888 276 4027.
Sincerely,
Sam Adettiwar, MS, PE, GE, P.Eng, M.ASCE
Senior Engineer
Attachments
FIGURES
FIGURE 1: SITE LOCATION MAPREFERENCE:
GOOGLE MAPS
USGS TOPOGRAPHIC MAPS
SITE LOCATION
SITE LOCATION
FIGURE 3: GEOLOGIC MAP
SITE LOCATION
LEGEND
REFERENCE:
U.S. GEOLOGICAL MAPS
REFERENCE:
WEB SOIL SURVEY FIGURE 4: SOIL SURVEY MAP
SITE LOCATION
LEGEND
FIGURE 5: LANDSLIDES HAZARD MAP
SITE LOCATION
REFERENCE:
COLORADO LANDSLIDES
INVENTORY
FIGURE 6 :DEBRIS FLOW HAZARD
SITE LOCATION
REFERENCE:
EAGLE COUNTY GIS
FIGURE 7: EVAPORITE FORMATION
SITE LOCATION
REFERENCE:
EAGLE COUNTY GIS
FIGURE 8: STEEP SLOPE AREA
SITE LOCATION
REFERENCE:
EAGLE COUNTY GIS
APPENDIX
SAND to SILTY SAND with GRAVEL/
COBBLES, medium to fine grain,
brown,dry to damp, medium dense to
dense,
(COLLUVIUM)
End of profile. Soils/bedrock conditions are
based on subsurface exploration, soils maps,
geology maps, and local experience.
Groundwater was not encountered during or at
the completion of drilling.
1.25
2.5
3.75
5.0
End of profile. Soils/bedrock conditions are
based on subsurface exploration, soils maps,
geology maps, and local experience.
Groundwater was not encountered during or at
the completion of drilling.
1.25
2.5
3.75
5.0
UNIFIED SOIL CLASSIFICATION AND SYMBOL CHART
COARSE-GRAINED SOILS (more than 50% of material is larger than No. 200 sieve size.)
GRAVELS More than 50% of coarse fraction larger than No. 4 sieve size
SANDS 50% or more of coarse fraction smaller than No. 4 sieve size
Clean Gravels (Less than 5% fines)
GW
GP
Well-graded gravels, gravel-sand mixtures, little or no fines
Poorly-graded gravels, gravel-sand mixtures, little or no fines
Gravels with fines (More than 12% fines)
GM
GC
Silty gravels, gravel-sand-silt mixtures
Clayey gravels, gravel-sand-clay mixtures
Clean Sands (Less than 5% fines)
SW
SP
Well-graded sands, gravelly sands, little or no fines
Poorly graded sands, gravelly sands, little or no fines
Sands with fines More than 12% fines
SM Silty sands, sand-silt mixtures
SC Clayey sands, sand-clay mixtures
FINE-GRAINED SOILS (50% or more of material is smaller than No. 200 sieve size.)
SILTS
AND
CLAYS Liquid limit less than 50%
SILTS
AND
CLAYS Liquid limit 50% or greater
HIGHLY ORGANIC SOILS
ML
CL
OL
MH
CH
OH
PT
Inorganic silts and very fine sands, rock flour, silty of clayey fine sands or clayey silts with slight plasticity
Inorganic clays of low to medium plasticity, gravelly clays, sandy clays, silty clays, lean clays
Organic silts and organic silty clays of low plasticity
Inorganic silts, micaceous or diatomaceous fine sandy or silty soils, elastic silts
Inorganic clays of high plasticity, fat clays
Organic clays of medium to high plasticity, organic silts
Peat and other highly organic soils
GW
GP
GM
GC
SW
SP
SM
SC
LABORATORY CLASSIFICATION CRITERIA
cu D 50 D 30 = --greater than 4; Cc = between 1 and 3 D 10 010 x D50
Not meeting all gradation requirements for GW
Atterberg limits below "A" Above "A" line with P.I. between line or P.I. less than 4 4 and 7 are borderline cases Atterberg limits above "A" requiring use of dual symbols line with P. I. greater than 7
cu D 50 D 30 = --greater than 4; Cc = between 1 and 3
D 10 01o xD60
Not meeting all gradation requirements for GW
Atterberg limits below "A" Limits plotting in shaded zone line or P.I. less than 4 with P.I. between 4 and 7 are
Atterberg limits above "A" borderline cases requiring use line with P. I. greater than 7 of dual symbols.
Determine percentages of sand and gravel from grain-size curve. Depending on percentage of fines (fraction smaller than No. 200 sieve size), coarse-grained soils are classified as follows: Less than 5 percent .................................... GW, GP, SW, SP More than 12 percent .................................. GM, GC, SM, SC 5 to 12 percent ................... Borderline cases requiring dual symbols
PLASTICITY CHART
60 ,,/ � � 50
� CH / /
>< 40 V" ALINE: Vp1 = on(LL-20) � 30 >-CL ,,/ MHlOH 20 / j:: / 10 ...J CL+ML ./ ML&OL II.. 0 0 I 10 20 30 40 50 60 70 80 90 100
LIQUID LIMIT (LL) (%)
DESCRIPTIVE TERMINOLOGY & SOIL CLASSIFICATION
UNIFIED SOIL CLASSIFICATION SYSTEM
DESCRIPTIVE TERMINOLOGY & SOIL CLASSIFICATION
LABORATORY/FIELD TESTING DEFINITIONS FOR
EXPLORATION LOGS
DD = DRY DENSITY (PCF)
WD = WET DENSITY (PCF)
MC = MOISTURE CONTENT (%)
PL = PLASTIC LIMIT (%)
LL = LIQUID LIMIT (%)
PI = PLASTICITY INDEX
OC = ORGANIC CONTENT (%)
S = SATURATION PERCENT (%)
SG = SPECIFIC GRAVITY
C = COHESION
Ф = ANGLE OF INTERNAL FRICTION
QU = UNCONFINED COMPRESSION
STRENGTH
#200 = PERCENT PASSING THE #200 SIEVE
CBR = CALIFORNIA BEARING RATIO
VS = VANE SHEAR
PP = POCKET PENETROMETER
DP = DRIVE PROBE
SPT = STANDARD PENETRATION TEST
BPF = BLOWS PER FOOT (N VALUE)
SH = SHELBY TUBE SAMPLE
GW = GROUND WATER
RQD = ROCK QUALITY DESIDNATION
TP = TEST PIT
B = BORING
HA = HAND AUGER
GROUNDWATER LEVEL/SEEPAGE
ENCOUNTERED DURING EXPLORATION
STATIC GROUNDWATER LEVEL WITH
DATE MEASURED
CONSISTENCY OF COHESIVE SOILS
CONSISTENCY STP (BPF) PP (TSF)
VERY SOFT 0-1 LESS THAN 0.25
SOFT 2 - 4 0.25 - 0.5
MEDIUM STIFF 5 - 8 0.5 - 1.0
STIFF 9 - 15 1.0 - 2.0
VERY STIFF 16 - 30 2.0 - 4.0
HARD 30+ OVER 4.0
RELATIVE DENSITY OF COHESIONLESS SOILS
DENSITY SPT (BPF)
VERY LOOSE 0 – 4
LOOSE 5 – 10
MEDIUM DENSE 11 – 30
DENSE 31 – 50
VERY DENSE 50+
PARTICLE SIZE IDENTIFICATION
NAME DIAMETER
(INCHES)
SIEVE NO.
ROCK BLOCK >120
BOULDER 12-120
COBBLE 3-12
GRAVEL
COURSE 3/4 - 3
FINE 1/4 – 3/4 NO. 4
SAND
COARSE 4.75 MM NO. 10
MEDIUM 2.0MM NO. 40
FINE .425 MM NO. 200
SILT .075 MM
CLAY <0.005 MM
GRAIN SIZE
FINE
GRAINED
<0.04 INCH FEW GRAINS ARE
DISTINGUISHABLE IN THE
FIELD OR WITH HAND LENS.
MEDIUM
GRAINED
0.04-0.2 INCH GRAINS ARE
DISTINGUISHABLE WITH THE
AID OF A HAND LENS.
COARSE
GRAINED
0.04-0.2 INCH MOST GRAINS ARE
DISTINGUISHABLE WITH THE
NAKED EYE.
SPT EXPLORATIONS:
STANDARD PENETRATION TESTING IS
PERFORMED BY DRIVING A 2 – INCH O.D. SPLIT-
SPOON INTO THE UNDISTURBED FORMATION AT
THE BOTTOM OF THE BORING WITH REPEATED
BLOWS OF A 140 – POUND PIN GUIDED HAMMER
FALLING 30 INCHES. NUMBER OF BLOWS (N
VALUE) REQUIRED TO DRIVE THE SAMPLER A
GIVEN DISTANCE WAS CONSIDERED A MEASURE
OF SOIL CONSISTENCY.
SH SAMPLING:
SHELBY TUBE SAMPLING IS PERFORMED WITH A
THIN WALLED SAMPLER PUSHED INTO THE
UNDISTURBED SOIL TO SAMPLE 2.0 FEET OF
SOIL.
AIR TRACK EXPLORATION:
TESTING IS PERFORMED BY MEASURING RATE
OF ADVANCEMENT AND SAMPLES ARE
RETRIEVED FROM CUTTINGS.
HAND AUGUR EXPLORATION:
TESTING IS PREFORMED USING A 3.25”
DIAMETER AUGUR TO ADVANCE INTO THE EARTH
AND RETRIEVE SAMPLES.
DRIVE PROBE EXPLORATIONS:
THIS “RELATIVE DENSITY” EXPLORATION DEVICE
IS USED TO DETERMINE THE DISTRIBUTION AND
ESTIMATE STRENGTH OF THE SUBSURFACE SOIL
AND DECOMPRESSED ROCK UNITS. THE
RESISTANCE TO PENETRATION IS MEASURED IN
BLOWS-PER-1/2 FOOT OF AN 11-POUND HAMMER
WHICH FREE FALLS ROUGHLY 3.5 FEET DRIVING
THE 0.5 INCH DIAMETER PIPE INTO THE GROUND.
FOR A MORE DETAILED DESCRIPTION OF THIS
GEOTECHNICAL EXPLORATION METHOD, THE
SLOPE STABILITY REFERENCE GUIDE FOR
NATIONAL FORESTS IN THE UNITED STATES,
VOLUME I, UNITED STATES DEPARTMENT OF
AGRICULTURE, EM-7170-13, AUGUST 1994, P. 317-
321.
CPT EXPLORATION:
CONE PENETROMETER EXPLORATIONS CONSIST
OF PUSHING A PROBE CONE INTO THE EARTH
USING THE REACTION OF A 20-TON TRUCK. THE
CONE RESISTANCE (QC) AND SLEEVE FRICTION
(FS) ARE MEASURED AS THE PROBE WAS
PUSHED INTO THE EARTH. THE VALUES OF QC
AND FS (IN TSF) ARE NOTED AS THE LOCALIZED
INDEX OF SOIL STRENGTH.
ANGULARITY OF GRAVEL & COBBLES
ANGULAR COARSE PARTICLES HAVE SHARP
EDGES AND RELATIVELY PLANE SIDES
WITH UNPOLISHED SURFACES.
SUBANGULAR COARSE GRAINED PARTICLES ARE
SIMILAR TO ANGULAR BUT HAVE
ROUNDED EDGES.
SUBROUNDED COARSE GRAINED PARTICLES HAVE
NEARLY PLANE SIDES BUT HAVE WELL
ROUNDED CORNERS AND EDGES.
ROUNDED COARSE GRAINED PARTICLES HAVE
SMOOTHLY CURVED SIDES AND NO
EDGES.
SOIL MOISTURE MODIFIER
DRY ABSENCE OF MOISTURE; DUSTY, DRY
TO TOUCH
MOIST DAMP BUT NO VISIBLE WATER
WET VISIBLE FREE WATER
WEATHERED STATE
FRESH NO VISIBLE SIGN OF ROCK MATERIAL
WEATHERING; PERHAPS SLIGHT
DISCOLORATION IN MAJOR
DISCONTINUITY SURFACES.
SLIGHTLY
WEATHERED
DISCOLORATION INDICATES
WEATHERING OF ROCK MATERIAL AND
DISCONTINUITY SURFACES. ALL THE
ROCK MATERIAL MAY BE DISCOLORED
BY WEATHERING AND MAY BE
SOMEWHAT WEAKER EXTERNALLY
THAN ITS FRESH CONDITION.
MODERATELY
WEATHERED
LESS THAN HALF OF THE ROCK
MATERIAL IS DECOMPOSED AND/OR
DISINTEGRATED TO SOIL. FRESH OR
DISCOLORED ROCK IS PRESENT EITHER
AS A CONTINUOUS FRAMEWORK OR AS
CORE STONES.
HIGHLY
WEATHERED
MORE THAN HALF OF THE ROCK
MATERIAL IS DECOMPOSED AND/OR
DISINTEGRATED TO SOIL. FRESH OR
DISCOLORED ROCK IS PRESENT EITHER
AS DISCONTINUOUS FRAMEWORK OR
AS CORE STONE.
COMPLETELY
WEATHERED
ALL ROCK MATERIAL IS DECOMPOSED
AND/OR DISINTEGRATED TO SOIL. THE
ORIGINAL MASS STRUCTURE IS STILL
LARGELY INTACT.
RESIDUAL SOIL ALL ROCK MATERIAL IS CONVERTED TO
SOIL. THE MASS STRUCTURE AND
MATERIAL FABRIC IS DESTROYED.
THERE IS A LARGE CHANGE IN VOLUME,
BUT THE SOIL HAS NOT BEEN
SIGNIFICANTLY TRANSPORTED.
DESCRIPTIVE TERMINOLOGY & SOIL CLASSIFICATION
Aspen-Gypsum Area, Colorado, Parts of Eagle,
Garfield, and Pitkin Counties
106—Tridell-Brownsto stony sandy loams, 12 to 50 percent
slopes, extremely stony
Map Unit Setting
National map unit symbol: jq4f
Elevation: 6,400 to 7,700 feet
Mean annual precipitation: 12 to 14 inches
Mean annual air temperature: 42 to 44 degrees F
Frost-free period: 85 to 105 days
Farmland classification: Not prime farmland
Map Unit Composition
Tridell and similar soils: 45 percent
Brownsto and similar soils: 35 percent
Minor components: 20 percent
Estimates are based on observations, descriptions, and transects of
the mapunit.
Description of Tridell
Setting
Landform: Mountains, terraces
Landform position (three-dimensional): Lower third of
mountainflank, tread
Down-slope shape: Linear
Across-slope shape: Linear
Parent material: Alluvium derived from sandstone and/or colluvium
derived from sandstone and/or alluvium derived from basalt
and/or colluvium derived from basalt
Typical profile
H1 - 0 to 2 inches: stony sandy loam
H2 - 2 to 14 inches: very cobbly fine sandy loam
H3 - 14 to 25 inches: cobbly sandy loam
H4 - 25 to 37 inches: very stony fine sandy loam
H5 - 37 to 60 inches: very stony loamy sand
Properties and qualities
Slope: 12 to 50 percent
Depth to restrictive feature: More than 80 inches
Natural drainage class: Well drained
Runoff class: Medium
Capacity of the most limiting layer to transmit water (Ksat):
Moderately high to high (0.60 to 6.00 in/hr)
Depth to water table: More than 80 inches
Frequency of flooding: None
Frequency of ponding: None
Calcium carbonate, maximum in profile: 25 percent
Map Unit Description: Tridell-Brownsto stony sandy loams, 12 to 50 percent slopes, extremely
stony---Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/15/2020
Page 1 of 3
Salinity, maximum in profile: Nonsaline to very slightly saline (0.0
to 2.0 mmhos/cm)
Available water storage in profile: Low (about 4.0 inches)
Interpretive groups
Land capability classification (irrigated): None specified
Land capability classification (nonirrigated): 7s
Hydrologic Soil Group: A
Other vegetative classification: Pinyon-Juniper (null_10)
Hydric soil rating: No
Description of Brownsto
Setting
Landform: Terraces
Landform position (three-dimensional): Tread
Down-slope shape: Linear
Across-slope shape: Linear
Parent material: Alluvium derived from basalt and/or coarse
textured alluvium derived from calcareous sandstone
Typical profile
H1 - 0 to 11 inches: stony sandy loam
H2 - 11 to 30 inches: very gravelly sandy loam
H3 - 30 to 42 inches: very gravelly loamy sand
H4 - 42 to 60 inches: gravelly sandy loam
Properties and qualities
Slope: 12 to 50 percent
Depth to restrictive feature: More than 80 inches
Natural drainage class: Well drained
Runoff class: Medium
Capacity of the most limiting layer to transmit water (Ksat):
Moderately high to high (0.60 to 6.00 in/hr)
Depth to water table: More than 80 inches
Frequency of flooding: None
Frequency of ponding: None
Calcium carbonate, maximum in profile: 30 percent
Salinity, maximum in profile: Nonsaline to very slightly saline (0.0
to 2.0 mmhos/cm)
Available water storage in profile: Low (about 4.2 inches)
Interpretive groups
Land capability classification (irrigated): None specified
Land capability classification (nonirrigated): 7e
Hydrologic Soil Group: A
Other vegetative classification: Stony Foothills (null_81)
Hydric soil rating: No
Minor Components
Other soils
Percent of map unit: 20 percent
Map Unit Description: Tridell-Brownsto stony sandy loams, 12 to 50 percent slopes, extremely
stony---Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/15/2020
Page 2 of 3
Hydric soil rating: No
Data Source Information
Soil Survey Area: Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and
Pitkin Counties
Survey Area Data: Version 11, Jun 5, 2020
Map Unit Description: Tridell-Brownsto stony sandy loams, 12 to 50 percent slopes, extremely
stony---Aspen-Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/15/2020
Page 3 of 3
IMPORTANT INFORMATION ABOUT YOUR
GEOTECHNICAL ENGINEERING REPORT
As the client of a consulting geotechnical engineer, you should know that site subsurface conditions cause more construction problems than any other factor. ASFE/the Association of Engineering Firms Practicing in the Geosciences offers the following suggestions and observations to help you manage your risks.
A GEOTECHNICAL ENG.NEERING REPORT IS BASED ON A UNIQUE SET OF PROJECT-SPECIFIC FACTORS Your geotechnical engineering report is based on a subsurface exploration plan designed to consider a unique set of project-specific factors. These factors typically include: the general nature of the structure involved, its size, and configuration; the location of the structure on the site; other improvements, such as access roads, parking lots, and underground utilities; and the additional risk created by scope-of-service limitations imposed by the client. To help avoid costly problems, ask your geotechnical engineer to evaluate how factors that change subsequent to the date of the report may affect the report's recommendations.
Unless your geotechnical engineer indicates otherwise, do not use your geotechnical engineering report:
MOST GEOTECHNICAL FINDINGS ARE PROFESSIONAL JUDGMENTS Site exploration identifies actual subsurface conditions only at those points where samples are taken. The data were extrapolated by your geotechnical engineer who then applied judgment to render an opinion about overall subsurface conditions. The actual interface between materials may be far more gradual or abrupt than your report indicates, Actual conditions in areas not sampled may differ from those predicted in your report. While nothing can be done to prevent such situations. you and your geotechnical engineer can work together to help minimize their impact. Retaining your geotechnical engineer to observe construction can be particularly beneficial in this respect.
•when the nature of the proposed structure ischanged. for example, if an office building willbe erected instead of a parking garage, or arefrigerated warehouse will be built instead ofan unrefrigerated one;•when the size, elevation. or configuration of theproposed structure is altered;•when the location or orientation of the proposedstructure is modified;•when there is a change of ownership; or .forapplication to an adjacent site.
Geotechnical engineers cannot accept responsibility for problems that may occur if they are not consulted after factors considered in their report's development have changed.
A REPORT'S RECOMMENDATIONS CAN ONLY BE PRELIMINARY The construction recommendations included in your geotechnical engineer's report are preliminary, because they must be based on the assumption that conditions revealed through selective exploratory sampling are indicative of actual conditions throughout a site.
Because actual subsurface conditions can be discerned only during earthwork, you should retain your geo- technical engineer to observe actual conditions and to finalize recommendations. Only the geotechnical engineer who prepared the report is fully familiar with the background information needed to determine whether or not the report's recommendations are valid and whether or not the contractor is abiding by applicable recommendations. The geotechnical engineer who developed your report cannot assume responsibility or liability for the adequacy of the report's recommendations if another party is retained to observe construction.
SUBSURFACE CONDITIONS CAN CHANGE A geotechnical engineering report is based on condi- tions that existed at the time of subsurface exploration. Do not base construction decisions on a geotechnical engineering report whose adequacy may have been affected by time. Speak with your geotechnical consult- ant to learn if additional tests are advisable before construction starts. Note, too, that additional tests may be required when subsurface conditions are affected by construction operations at or adjacent to the site, or by natural events such as floods, earthquakes, or ground water fluctuations. Keep your geotechnical consultant apprised of any such events.
GEOTECHNICAL SERVICES ARE PERFORMED FOR SPECIFIC PURPOSES AND PERSONS Consulting geotechnical engineers prepare reports to meet the specific needs of specific individuals. A report prepared for a civil engineer may not be adequate for a construction contractor or even another civil engineer. Unless indicated otherwise, your geotechnical engineer prepared your report expressly for you and expressly for purposes you indicated. No one other than you should apply this report for its intended purpose without first conferring with the geotechnical engineer. No party should apply this report for any purpose other than that originally contemplated without first conferring with the geotechnical engineer.
GEOENVIRONMENTAL CONCERNS ARE NOT AT ISSUE Your geotechnical engineering report is not likely to relate any findings, conclusions, or recommendations
ASFE
8811 Colesville Road/Suite G106/Silver Spring, MD 20910
Telephone: 301/565-2733 Facsimile: 301/589-2017
about the potential for hazardous materials existing at the site. The equipment, techniques, and personnel used to perform a geoenvironmental exploration differ substantially from those applied in geotechnical engineering. Contamination can create major risks. If you have no information about the potential for your site being contaminated. you are advised to speak with your geotechnical consultant for information relating to geoenvironmental issues.
A GEOTECHNICAL ENGINEERING REPORT IS SUBJECT TO MISINTERPRETATION Costly problems can occur when other design profes- sionals develop their plans based on misinterpretations of a geotechnical engineering report. To help avoid misinterpretations, retain your geotechnical engineer to work with other project design professionals who are affected by the geotechnical report. Have your geotechnical engineer explain report implications to design professionals affected by them. and then review those design professionals' plans and specifications to see how they have incorporated geotechnical factors. Although certain other design professionals may be fam- iliar with geotechnical concerns, none knows 'as much about them as a competent geotechnical engineer.
BORING LOGS SHOULD NOT BE SEPARATED FROM THE REPORT Geotechnical engineers develop final boring logs based upon their interpretation of the field logs (assembled by site personnel) and laboratory evaluation of field samples. Geotechnical engineers customarily include only final boring logs in their reports. Final boring logs should not under any circumstances be redrawn for inclusion in architectural or other design drawings. because drafters may commit errors or omissions in the transfer process. Although photographic reproduction eliminates this problem, it does nothing to minimize the possibility of contractors misinterpreting the logs during bid preparation. When this occurs. delays. disputes. and unanticipated costs ara the all-too-frequent result.
To minimize the likelihood of boring log misinterpretation, give contractors ready access to the complete geotechnical engineering report prepared or authorized for their use. (If access is provided only to the report prepared for you, you should advise contractors of the report's limitations. assuming that a contractor was not one of the specific persons for whom the report was prepared and that developing
construction cost estimates was not one of the specific purposes for which it was prepared. In other words. while a contractor may gain important knowledge from a report prepared for another party, the contractor would be well-advised to discuss the report with your geotechnical engineer and to perform the additional or alternative work that the contractor believes may be needed to obtain the data specifically appropriate for construction cost estimating purposes.) Some clients believe that it is unwise or unnecessary to give contractors access to their geo- technical engineering reports because they hold the mistaken impression that simply disclaiming responsibility for the accuracy of subsurface information always insulates them from attendant liability. Providing the best available information to contractors helps prevent costly construction problems. It also helps reduce the adversarial attitudes that can aggravate problems to disproportionate scale.
READ RESPONSIBILITY CLAUSES CLOSELY Because geotechnical engineering is based extensively on judgment and opinion, it is far less exact than other design disciplines. This situation has resulted in wholly unwarranted claims being lodged against geotechnical engineers. To help prevent this problem, geotechnical engineers have developed a number of clauses for use in their contracts, reports, and other documents. Responsibility clauses are not exculpatory clauses designed to transfer geotechnical engineers' liabilities to other parties. Instead, they are definitive clauses that identify where geotechnical engineers' responsibilities begin and end. Their use helps all parties involved recognize their individual responsibilities and take appropriate action. Some of these definitive clauses are likely to appear in your geotechnical engineering report. Read them closely. Your geotechnical engineer will be pleased to give full and frank answers to any questions.
RELY ON THE GEOTECHNICAL ENGINEER FOR ADDITIONAL ASSISTANCE Most ASFE-member consulting geotechnical engineering firms are familiar with a variety of techniques and approaches that can be used to help reduce risks for all parties to a construction project, from design through construction. Speak with your geotechnical engineer not only about geotechnical issues, but others as well, to learn about approaches that may be of genuine benefit. You may also wish to obtain certain ASFE publications. Contact a member of ASFE of ASFE for a complimentary directory of ASFE publications.
Subsurface Explorations
Soil Testing
Earthwork Monitoring
Geotechnology
Foundation Engineering
Rock Mechanics
Earthquake Engineering
Geophysics
Retaining Wall Design
Geostrructural Design
Pavement Design
Drainage Evaluations
Groundwater Studies
Environmental Assets
Building Assessments
AmericanGeoServices.com
8/18/2021 Eagle County Government Mail - Watts (pump tank substitution)
https://mail.google.com/mail/u/0?ik=da50768ddd&view=pt&search=all&permthid=thread-f%3A1707996864897184293&simpl=msg-f%3A17079968648…1/3
Claire Lewandowski <claire.lewandowski@eaglecounty.us>
Watts (pump tank substitution)
5 messages
Carla Ostberg <carla.ostberg@gmail.com>Fri, Aug 13, 2021 at 10:38 AM
To: Claire Lewandowski <claire.lewandowski@eaglecounty.us>, hornhunter@sopris.net
Hi Claire,
I left you a voicemail yesterday. 500 gal poly pump tanks are apparently not available right now. Given the extremely
difficult digging on this site, we don't want to put in a larger chamber/tank. There are also no concrete pump tanks
available locally (grand junction to buena vista).
Wondering if Jim (cc'd here) could substitute solid drywell rings. There would be a seam that he would rubberneck and
seal with an epoxy both inside and outside.
This is what I can find in the regs:
Concrete Septic Tank Structural Design
a. Concrete septic tanks must comply with the structural design criteria of ASTM C1227-13
(2013 version) (Standard Specification for Precast Septic Tanks).
b. The design for each tank model and size by each manufacturer must be certified by a professional engineer as
complying with these design and structural requirements and the watertightness standard of this regulation.
c. Certification by a professional engineer must be submitted to the Division for acceptance.
d. Tank slab lids, mid-seam tanks, and the connections between the tank and risers must be designed to provide
for a watertight seal.
__________________________________________
if we got something from the concrete company that this would be an acceptable use, would that work? Jim, do you
think you could get something in writing from the concrete company you would get the materials from?
It's really a bummer than parts and pieces are unavailable. It's making it difficult to keep projects moving.
Carla Ostberg
CBO Septic Consulting
970.309.5259
Office
981 Cowen Drive, B-7
Carbondale, CO 81623
Mailing (RECENTLY CHANGED)
129 Cains Lane
Carbondale, CO 81623
Claire Lewandowski <claire.lewandowski@eaglecounty.us>Fri, Aug 13, 2021 at 11:01 AM
To: Carla Ostberg <carla.ostberg@gmail.com>
Cc: hornhunter@sopris.net
Hi Carla,
As far as I understand, every tank, including pump tanks, must be approved by CDPHE. So the proposal to use sealed
drywell rings would not be approved. I will forward this to Chuck Cusino to see if he is receiving similar requests.
8/18/2021 Eagle County Government Mail - Watts (pump tank substitution)
https://mail.google.com/mail/u/0?ik=da50768ddd&view=pt&search=all&permthid=thread-f%3A1707996864897184293&simpl=msg-f%3A17079968648…2/3
Thank you,
Claire
[Quoted text hidden]
--
Claire Lewandowski, REHS
Environmental Health Specialist III
970-328-8755 (office)
970-328-8747 (direct)
environment@eaglecounty.us
www.eaglecounty.us
Claire Lewandowski <claire.lewandowski@eaglecounty.us>Fri, Aug 13, 2021 at 11:02 AM
To: Chuck Cousino - CDPHE <chuck.cousino@state.co.us>
Forwarding =, let me know if you have been hearing similar requests. Thanks!
[Quoted text hidden]
Carla Ostberg <carla.ostberg@gmail.com>Fri, Aug 13, 2021 at 11:05 AM
To: Claire Lewandowski <claire.lewandowski@eaglecounty.us>
Cc: hornhunter@sopris.net
OK thank you.
I like the idea of bringing Chuck into the conversation. There are a lot of substitutions happening right now because of
lack of availabity. It's a huge problem.
Carla Ostberg
CBO Septic Consulting
970.309.5259
Office
981 Cowen Drive, B-7
Carbondale, CO 81623
Mailing (RECENTLY CHANGED)
129 Cains Lane
Carbondale, CO 81623
[Quoted text hidden]
Cousino - CDPHE, Chuck <chuck.cousino@state.co.us>Mon, Aug 16, 2021 at 10:31 AM
To: Claire Lewandowski <claire.lewandowski@eaglecounty.us>
Claire,
Technically, this is what secon 43.13.B of Reg. 43 states:
B. The Division must review and provide either comment or acceptance to the manufacturer for
proprietary products in these technology categories:
1. Proprietary treatment products (e.g. treatment systems);
2. Proprietary distribution products (e.g. manufactured distribution products or subsurface
dripline);
8/18/2021 Eagle County Government Mail - Watts (pump tank substitution)
https://mail.google.com/mail/u/0?ik=da50768ddd&view=pt&search=all&permthid=thread-f%3A1707996864897184293&simpl=msg-f%3A17079968648…3/3
3. Septic tanks;
4. Others as needed
Note that “pump chambers” are not specifically stated. As such, while I think that it would be a good idea for
CDPHE to review single tank pump chambers, we currently only review them upon request of the mfgr.
From this, if you feel that the situation warrants your acceptance of this configuration for this specific site, the
regulation does not prohibit you from doing so. However, as you are aware, local agencies may always be
more stringent than the state regulation. If you feel inclined to approve the proposal, I’d recommend that at a
minimum, a low water alarm/redundant off float be included in this design.
Feel free to contact me should you have any questions.
Thank you,
Chuck Cousino, REHS
OWTS Coordinator
Engineering Section
P 303.692.2366 | F 303.758.1398
4300 Cherry Creek Drive South, Denver, CO 80246
Chuck.Cousino@state.co.us | www.colorado.gov/cdphe/wqcd
24-hr Environmental Release/Incident Report Line: 1.877.518.5608
On Fri, Aug 13, 2021 at 11:02 AM Claire Lewandowski <claire.lewandowski@eaglecounty.us> wrote:
[Quoted text hidden]
Claire Lewandowski <claire.lewandowski@eaglecounty.us>
390 Paseo / Watts
1 message
Carla Ostberg <carla.ostberg@gmail.com>Wed, May 26, 2021 at 12:09 PM
To: Ryan Watts <rywatts@hotmail.com>, Claire Lewandowski <claire.lewandowski@eaglecounty.us>, Danielle Sell <danielle.sell@eaglecounty.us>, Romeo Baylosis
<romeo@rbcivil.com>
Hi Everyone,
The test pit was dug yesterday and while digging was difficult, soils were consistent with what was assumed for the design. And unlike the neighbor, we did not
hit shelf rock in the area of the proposed STA.
This is a relatively small area and I advised only one test pit be dug to minimize the disturbance and because of the rock content, the pit ends up being bigger
than standard.
Let me know if you have any objections to that. thank you!
Carla Ostberg
CBO Septic Consulting
970.309.5259
Office
981 Cowen Drive, B-7
Carbondale, CO 81623
Mailing
33 Four Wheel Drive Road
Carbondale, CO 81623
4 attachments
IMG_2840.jpeg
175K
IMG_2838.jpeg
190K
PM_ENV_OWTS_Permit-4-1-2021.pdf
71K
C1591 OWTS Design Packet 3 7 21.pdf
6928K