HomeMy WebLinkAbout1435 Gore Trl - 210715302001Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-026354-2023 Permit Type: OWTS Permit Work Classification: New Permit Status: Active Issue Date: 3/28/2023 Expires: 7/26/2023 On-Site Wastewater Treatement System Project Address Parcel Number 1435 GORE TRL, EDWARDS AREA,210715302001 Owner Information Address Steve Garrison 1435 Gore Trail Edwards, CO 81632 Phone: Cell: Email: troutguy5@gmail.com Inspections: For Inspections Call: (970) 328-8755 Engineer Phone Email LKP Engineering, Inc., Luiza Petrovska, PE (970) 390-0307 luiza@lkpeng.com Contractor License Number Phone Email Scott Development cliverdevelopment@gmail. com (970) 390-6389OWTSPL-000230-20 23 Permitted Construction / Details: Install the new system exactly as depicted in the LKP Inc design dated January 20, 2022, stamped and signed on March 20, 2023 by Luiza Petrovska, PE. This system is designed to accommodate the maximum daily flows for a 4 bedroom residence. The OWTS consists of one sewer line from the residence. A 1,500 gallon, three-compartment, Valley Precast septic tank with a total volume of 2000 gallons and an effluent filter in the outlet tee will be used. An Orenco PF5005 high head pump assembly will be installed in the third compartment. The pump will be set to dose 90 gallons per dose. The STA consists of a 2 foot unlined sand filter bed with four rows of 17 Infiltrator Quick4 Plus Standard chambers for a total of 68. Gradation analysis should confirm that sand is secondary media. Install distribution lateral orifice size, orifice shields, spacing, and flushing assemblies should be completed as designed. Inspection ports should be present at each corner of the bed. Do not dig in wet or frozen ground. Location of the water line will be recorded in the record drawing. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Danielle Salinsky Date March 28, 2023 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Tuesday, March 28, 2023 1 Inspection Result Eagle County, Colorado P.O. Box 179 500 Broadway Eagle, CO Phone: (970) 328-8730 Fax: (970) 328-7185 IVR Phone: 1-866-701-3307 Inspection Number: INSP-526722-2023 Permit Number: OWTS-026354-2023 Inspection Date: 10/26/2023 Inspector: Weems, Kirk Permit Type: OWTS Permit Inspection Type: OWTS Final Inspection Work Classification: NewOwner:Steve Garrison Job Address:1435 GORE TRL IVR Pin Number:198392 EDWARDS AREA, CO Project:<NONE> Parcel Number:210715302001 Contractor:Phone: (970) 390-6389 / Cell: (970) 390-6389Cliver Development Inspection Status: Approved Inspection Notes Inspector Comments Added Item: Septic Tank 10/26/23 - Tank sizing confirmed 1500 gal, Valley Precast 3-CP. Effluent filters in place on outlet tee from 2nd chamber, and in BioTube in dosing chamber. Confirm tees in place, tank level. Added Item: Record Drawing Received 11/14/2023 from LKP. Added Item: Record Photos Received 11/14/2023 from LKP. Added Item: Site and Soil Received 3/28/2023 from LKP. Added Item: Final Certification Letter Received 11/14/2023 from LKP. Added Item: General Plan 10/26/23 - Confirm general compliance with approve PE plans with exception of STA. See notes for STA. Tank, pumps, cleanouts, setbacks are all confirmed to approved PE plans. Added Item: Soil Treatment Area (STA) Wednesday, November 15, 2023 For more information visit: http://www.eaglecounty.us Page 1 of 2 10/26/23 - STA not installed to approved PE plan. LKP is returning pre-backfill to ensure corrections. - Inspection ports were inserted into sand filter, below infiltrative surface. Pipes were raised to keep perforations above infiltrative surface, and contractor will add perforations to pipe to ensure they are present - Distribution laterals were installed with orifices pointing down into infiltrative surface. Contractor will correct for follow-up inspection from LKP. - test could not confirm dynamic head at distal end of laterals due to incorrect alignment of orifices. LKP will confirm squirt test on re-inspection. - correct number of chambers present. Sand gradation on file in drive. Added Item: Identification of Systems Contractor Scott Cliver was the licensed installer. Wednesday, November 15, 2023 For more information visit: http://www.eaglecounty.us Page 2 of 2 P.O. Box 724, Eagle, CO 81631 Tel. (970) 390-0307 www.LKPEngineering,com November 14, 2023 Steve Garrison 122 Berry Place Erie, CO 80516 Troutguy5@gmail.com RE: Inspection of Septic System Installation Garrison - 4 Bedroom Residence Lot 7, Block 1, Cordillera Filing No. 34 1435 Gore Trail Eagle County, Colorado Project No. 21-3539– OWTS-026354-2023 Dear Steve: At the request of the installer, Scot Cliver, Scott Development, on August 18, October 26, and November 6, 2023 we visited your property on Lot 7, Block 1, Cordillera Filing No. 34, 1435 Gore Trail, Eagle County, Colorado. The purpose of our site visits was to inspect the installation of the septic system. The system was installed in overall compliance with the septic system design, Drawing No. 21- 3539OWTS.dwg, dated March 20, 2023. At the time of the inspection, we observed the following: The building sewer line was connected to the east side of the residence, near the NE building corner. The cleanout was 22 inches south of the NE building corner, and 3.7 feet east, as shown on the attached as- built sketch. The building sewer line was about 29 feet of 4-inch diameter SDR35 PVC pipe. They installed 1500-gallons, three compartments, precast, concrete, septic tank by Valley Precast with an effluent filter in the second compartment and an Orenco PF500511 high-head pump assembly in the third compartment. The inlet of the tank had the sanitary Tee installed. The tank access ports had corrugated, plastic risers with secured, green, plastic covers. The covers were secured with nuts, bolts, and screws. All risers were about 24-inch high. The control panel was installed on the north side of the residence, at the NE corner. The effluent line from the pump chamber to end manifold of the soil treatment area, was about 22 feet long, 1.5-inch diameter, sch40 pvc pipe. The end manifold was about 8 feet long, 1.25-inch sch40 pvc. The soil treatment area consisted of infiltrator chambers arranged in a bed configuration with four rows of 17 Quick Four Plus Standard Infiltrator Chambers in each. Two feet of the onsite silty, clayey, soil with basalt rocks of cobble and boulder size, was overexcavated from the bottom of the trenches and replaced with two feet of secondary sand media (the graph is attached to this report). Pressure dosing system consisting of 68-ft, 1.25- inch sch40 laterals perforated at the top with 1/8-inch holes at 4-ft intervals, suspended from the inside side of each row of infiltrator chambers. The ends of the laterals were equipped with flushing assemblies. A squirt test was performed during the inspection and it was satisfactory. Claire and Kurt from the ECEH Department were present during the inspection and the squirt test as well. All inspection ports were installed (in the end caps of the first and last chamber of each row of infiltrators) in the opening opposite the pressure distribution lines. The septic tank installation and startup of the pump system were done by Valley Precast. Start up letter attached. There is no other warranty either expressed or implied. Sincerely, LKP Engineering, Inc. Luiza Petrovska, PE cc: Eagle County Environmental Health Department E-mail: Claire Lewandowski claire.lewandowski@eaglecounty.us; environment@eaglecounty.us J:\_WP X4-LKP\_2021\21-3539OSIQ4PLUS-BEDSAND-PRESSURE.DOCX 11/14/2023 1500 GALLONS, THREE COMPARTMENTS CONCRETE SEPTIC TANK WITH EFFLUENT FILTER AND ORENCO PUMP ASSEMBLY BY VALLEY PRECAST OR EQUIVALENT ABOUT 29 FEET OF 4-INCH DIAMETER SDR35 PVC, BUILDING SEWER LINE DRILLED ONE 1/4-INCH HOLE AT THE INVERT OF THE FAR END OF EACH LATERAL (TYPICAL) ABOUT 22 FEET OF 1.5 INCH SCH40 PVC TRANSPORT (EFFLUENT LINE) CONTROL PANEL CLEANOUT FLUSHING ASSEMBLY THROUGH THE END CAPS SEE DETAIL INSPECTION PORT (TYPICAL IN THE FIRST AND LAST INFILTRATOR CHAMBER OF EACH ROW, INSTALLED IN THE OPENING OF THE CAP OPPOSITE OF THE PRESSURE LINE ~68 FEET OF 1.25-INCH SCH40 PVC LATERAL, PERFORATED WITH 1/8-INCH HOLES AT 4-FOOT INTERVALS AT THE TOP OF THE PIPE (TYPICAL) END CAP (TYP)~ 8' END MANIFOLD, 1.25 INCH DIAMETER SCH40 PVC STA BED WITH FOUR ROWS OF 17 INFILTRATOR CHAMBERS EACH QUICK 4 PLUS, STANDARD INFILTRATOR CHAMBER (TYPICAL) 56' 30' INSPECTION PORT (TYP.) GOR E T R A I L (50' R . O . W . ) SKETCH PROJECT NO.: DATE: PROJECT DESCRIPTION:LKP Engineering, Inc. CIVIL/GEOTECHNICAL PERMIT NO.:AS-BUILT 21-3539 OWTS-026354-2023 8/18, 10/23, & 11/6/2023 P.O. Box 724 Eagle, CO 81631, (970) 390-0307, www.LKPEngineering.com GARRISON, 4-BEDROOM RESIDENCE LOT 7, BLOCK 1, CORDILLERA FILING No. 34 1435 GORE TRAIL EAGLE COUNTY, COLORADO 10/25/2023 To Whom It May Concern: We have been to the following site: 1435 Gore Trail, Edwards, Eagle County We have verified that the system was started properly. The System went through several cycles with no issues. - Amperage and voltage of control panel, floats, and pump are all within manufacturers specifications and tolerance at start up. - Floats verify for functionality. - High level alarm functions upon activation at control panel. If you have any questions, please do not hesitate to call me at 719-395-6764, ext. 13. Sincerely, Scott McIntosh Service Manager PROFILE HOLE #10 TO 2.0 FEET TOPSOIL WITHROOTS2.0 TO 8 FEET BROWN, CLAYEY,GRAVELLY SAND WITH COBBLESAND SOME BOULDERSNO GROUND WATERENCOUNTEREDDESIGN CALCULATIONSDESIGN LONG TERM ACCEPTANCE RATE RATE = 0.65 GPD/SFNUMBER OF BEDROOMS: 4MAXIMUM DAILY FLOW = QMAXQmax = 3 BEDROOMS X 2 PERSONS/BEDROOM X 75 GALLONS/PERSON/DAY + 1 BEDROOM AT 75 GPDQMAX = 525 GPDSEPTIC TANKV = 1000 GALLONS FOR 2 TO 3 BEDROOMS PLUS 250 GALLONS FOR EACH ADDITIONAL BEDROOMUSE 1500-GALLONS THREE COMPARTMENTS, CONCRETE SEPTIC TANK WITH EFFLUENT FILTER, AND HIGHHEAD PUMP BY VALLEY PRECAST OR EQUIVALENT APPROVED BY THE ENGINEER.ABSORPTION AREABASED ON APPLICATION RATE:A = 525GPD/0.65GPD/S.F.A = 808.3S.F.QUICK 4 PLUS, STANDARD INFILTRATOR CHAMBER SYSTEM IN A BED CONFIGURATION CONSTRUCTED OVER2 FOOT OF UNLINED SAND FILTERSURFACE AREA OF ONE QUICK4, PLUS STANDARD INFILTRATOR CHAMBER = 12 S.F.USE 68 QUICK4, PLUS, STANDARD, INFILTRATOR CHAMBERS IN BED AS SHOWN ON THE PLAN.NOTES:1. BENDS IN THE BUILDING SEWER SHALL BE LIMITED TO 45 DEGREES.2. THE SEPTIC TANK SHALL BE INSTALLED LEVEL.3. THE TANK SHALL HAVE RISERS OVER EACH ACCESS MANHOLE AND ALL RISERS SHALL EXTEND TO ORABOVE FINAL GRADE.4. EACH RISER LEAD WILL HAVE A SECURE CLOSING MECHANISM, SUCH AS A LOCK, SPECIAL HEADED BOLTSOR SCREWS, OR SUFFICIENT WEIGHT TO PREVENT UNAUTHORIZED ACCESS.5.THE SEPTIC TANK AND ALL THE PIPING WILL BE BACKFILLED UP TO THE INVERTS PRIOR TO SCHEDULINGAN INSPECTION.6. THE BED WITH THE INFILTRATOR CHAMBERS SHALL BE INSTALLED LEVEL, ALONG THE CONTOUR.7. EXCAVATE NINE (12) FEET WIDE BED8. THE BOTTOM AND THE SIDEWALLS OF THE BED SHALL BE RAKED (IF NEEDED) TO ELIMINATE SMEARING.8. THE BED WILL BE EXCAVATED ADDITIONAL THREE FEET BELOW THE PROPOSED BOTTOM OF THEINFILTRATOR CHAMBERS FOR THE SAND FILTER PLACEMENT.9.THE CLASSIFICATION OF THE SAND TO BE USED IN THE BED OF THE SOIL TREATMENT AREA (STA) MUSTBE LESS THAN 30 DAYS OLD AND SUBMITTED TO THE ENGINEER PRIOR TO THE SAND FILL PLACEMENT.10. MARK A LINE ON THE BED EXCAVATION WALLS AT THE 2-FOOT DEPTH FROM THE BOTTOM WITH SPRAYPAINT BEFORE THE SAND PLACEMENT11. PLACE THE SEND FILTER IN THE PREPARED BED TO THE MARKED DEPTH12. ASSEMBLE AND INSTALL THE INFILTRATOR CHAMBERS IN THE BED ACCORDING TO THE MANUFACTURERSRECOMMENDATIONS.13. INSTALL THE PERFORATED PRESSURE DISTRIBUTION LATERALS ACCORDING TO THE MANUFACTURERSRECOMMENDATIONS.14. SCHEDULE INSPECTION OF THE SYSTEM AND A SQUIRT TEST OF THE LATERALS15. BACKFILL THE SIDEWALL AREA WITH NATIVE ON-SITE SOIL FOR PROPER SUPPORT.16. BACKFILL THE BED WITH A MINIMUM OF 12 INCHES OF TAMPED SOIL COVER.17. THE FINAL GRADING OVERT THE STA WILL PROVIDE FOR UNIFORM RUNOFF AWAY FROM THE SOILTREATMENT AREA, WITHOUT ALLOWING WATER TO PUDDLE ON TOP.18. AVOID VEHICLE TRAFFIC OVER THE SYSTEM.19. ALL INSTALLATIONS SHALL MEET THE RULES AND REGULATIONS OF THE EAGLE COUNTYENVIRONMENTAL HEALTH DEPARTMENT AND OWTS REG 43 EFFECTIVE AUGUST 24, 2018 .20.FOR THE INSPECTION OF THE SEPTIC SYSTEM - NOTIFY THE EAGLE COUNTY ENVIRONMENTAL HEALTHDEPARTMENT AND THE DESIGN ENGINEER A MINIMUM OF 48-HOURS PRIOR TO BACKFILLING ANY PART OFTHE SYSTEM TO SCHEDULE AN INSPECTION.PROFILE HOLE NO. 20 TO 1.0 FEET TOPSOIL1.0 TO 2.5 FEET BLOCKYCLAY WITH COBBLES OVERBASALT COBBLES ANDBOULDERSNO GROUND WATERENCOUNTEREDUSE PRESSURE DISTRIBUTION, WITH 2 FEET OF UNLINED SAND FILTER (SECONDARY SAND ASSUMED)DESIGN: LTAR OF THE RECEIVING SOIL FOR TL3 (TABLE 10-1) = 0.65GPD/SFFROM PROFILE HOLES 1 AND 3 - SAMPLE AT 4 FEET, RIBBON 1"-2", EQUALLY GRITTY ANDSMOOTH, TYPE 3 SOIL, >35% - 65% ROCK>2MM, CLAY LOAM - LTAR = 0.35 GPD/SF, R-1, OPTION 1PROFILE HOLE NO. 30 TO 1.0 FEET TOPSOIL ROOTS TO 2FEET1 TO 7 FEET CLAYEY, GRAVELLYSAND WITH COBBLES AND SOMEBOULDERSNO GROUND WATERENCOUNTERED9355GORE TRAIL (50' R.O.W.)13'13'B - 1PROF - 3PROF - 1PROF - 21500 GALLONS, THREE COMPARTMENTSCONCRETE SEPTIC TANK WITH EFFLUENTFILTER AND ORENCO PUMP ASSEMBLY BYVALLEY PRECAST OR EQUIVALENTABOUT 38 FEET OF 4-INCHDIAMETER SDR35 PVC, BUILDINGSEWER LINE (THE FIRST AND LAST5 FEET AT 2 TO 5% SLOPE)DRILL ONE 1/4-INCH HOLE AT THE INVERT OFTHE FAR END OF EACH LATERAL FOR DRAININGOF THE REMAINING EFFLUENT FROM THE PIPEBETWEEN DOSING AND PLACE A ROCK UNDERIT TO PREVENT EROSION (TYPICAL)ABOUT 31 FEET OF 1.5 INCH SCH40PVC TRANSPORT (EFFLUENT LINE)INVout=9352'INVout=9351'INVin=9351.24'68'~1228'~28'CLEANOUT12.5'FLUSHING ASSEMBLYTHROUGH THE ENDCAPS SEE DETAIL69'INSPECTION PORT (TYPICAL IN THE FIRSTAND LAST INFILTRATOR CHAMBER OF EACHROW, INSTALLED IN THE OPENING OF THECAP OPPOSITE OF THE PRESSURE LINE~68 FEET OF 1.25-INCH SCH40 PVCLATERAL, PERFORATED WITH 1/8-INCHHOLES AT 4-FOOT INTERVALS AT THETOP OF THE PIPE (TYPICAL)INVin=9350'END CAP (TYP)~ 10' END MANIFOLD,1.25 INCH DIAMETERSCH40 PVCSTA BED WITH FOUR ROWSOF 17 INFILTRATORCHAMBERS EACHQUICK 4 PLUS, STANDARDINFILTRATOR CHAMBER(TYPICAL)B - 2GORE TRAILGRANITE SPRINGSPIKES WAYINFILTRATOR SYSTEMS INC.QUICK4 PLUS STANDARD CHAMBERPRODUCT SPECIFICATION(NOT TO SCALE)PRESSURIZED PIPE DRILLPOINTS LOCATIONS(2 PLACES)(EFFECTIVE LENGTH)TOP VIEWSIDE VIEW END VIEWQUICK4 PLUS ALL-IN-ONE 12 END CAPINSPECTION PORTINFILTRATOR SYSTEMS INC.QUICK4 PLUS STANDARD CHAMBERTYPICAL BED DETAILSECTION VIEW(NOT TO SCALE)NATIVE BACKFILLTOPSOIL2'SAND FILTERPRIMARY ORSECONDARYPRESSUREDISTRIBUTIONLINES4-FTMAX.ESTABLISH VEGETATIVE COVER12-FTSAND FILL PLACEMENTPLACE THE SAND FILL MATERIAL IN THE EXCAVATED BED.THE FILTERING MATERIAL USED IN A SAND FILTER MUST BE CLEAN, COARSESAND, CLASSIFIED AS PRIMARY SAND OR SECONDARY SAND. THE ABOVEDESIGN WAS PREPARED BASED ON SECONDARY SAND.THE CLASSIFICATION OF THE SAND TO BE USED IN THE BED OF THE SOILTREATMENT AREA (STA) MUST BE LESS THAN 30 DAYS OLD AND SUBMITTEDTO THE ENGINEER PRIOR TO THE SAND FILL PLACEMENT.PROPOSED 4-BRMRESIDENCECLEANOUTPROPOSEDINVin=9351.24'OWTS X-SECTION SKETCHN.T.S~10' END MANIFOLD1.25-INCH SCH40 PVCABOUT 31 FEET OF 1.5 INCH SCH40PVC TRANSPORT (EFFLUENT LINE)EL=9354.5'INVout=9351'INVout =9352'LOWEST FLOOREL=9357'ABOUT 38 FEET OF 4-INCHDIAMETER SDR35 PVC,BUILDING SEWER LINE (THEFIRST AND LAST 5 FEET AT2 TO 5% SLOPE)GROUND ELEVATION VARIESFROM THE UPPER SIDE TO THELOWER SIDE OF THE STA BEDMANIFOLDINVin=9350'GROUND ELEVATION~9356'BOTTOM OF ALLINFILTRATORSAT =~9349.5'SAND FILTERPRIMARY ORSECONDARY12-FT2'SITE PLAN BYERIC JOHNSON, ARCHITECTTYPICAL FLUSHING ASSEMBLYAND INSPECTION PORT(EFFECTIVE LENGTH)SIDE VIEWValve BoxBall ValveFLUSHING ASSEMBLYN.T.S.SweepingEllbowEndCapSQUIRT TEST OF THE RESIDUAL HEAD OF THESTA BED LATERALSREMOVE THE END CAPS OF THE FLUSHINGASSEMBLY IN ORDER TO FLUSH THE LATERALSCLEAN FROM ANY DRILLING DEBRIS OR DIRT.DO NOT INSTALL THE LAST INFILTRATORCHAMBER SO THAT THE PERFORATIONS ONTHE LATERALS ARE OPEN IN ORDER TO RUNTHE SQUIRT TEST FOR THE MEASUREMENT OFTHE 5-FT RESIDUAL HEAD (+/-10%). THEPREPARATIONS FOR THE SQUIRT TEST MUSTBE READY FOR THE TEST TO BE DONE DURINGTHE FINAL INSPECTION.AFTER THE TEST, INSTALL THE LAST CHAMBERON ALL ROWS.PUMP SELECTIONA DISCHARGE PUMP CAPABLE OFDELIVERING 31.3 GPM AGAINST 15.3 FEETOF TOTAL DYNAMIC HEAD WILL BE USED.THE ELEVATIONS BETWEEN THE PUMPINVERT AND THE INVERT OF THEDISTRIBUTION VALVE SHOULD BE FIELDVERIFIED AND REPORTED BACK TO THEENGINEER.FOR THE DISCHARGE PUMP USEORENCO, PF500511 HIGH HEAD EFFLUENTPUMP. THE PUMP DOSING WILL BE ONDEMAND WITH 90 GALLONS PER DOSE.VENT CAPOPEN BOTTOMVENT CAPINSPECTION PORT4-INCH DIAMETERSDR35 WITHPERFORATIONS ONTHE BOTTOM 8-INCHES2'12"+ATTACH TOINFILTRATORWITH A RING ORSCREWSINSPECTION PORTN.T.S.FINISHEDGRADEOPEN BOTTOMPRESSURE DISTRIBUTIONLATERAL (TYP.)Valve BoxBall ValveDRAWN BY:CHECKED BY:PROJECT NO.:SHEET:DRAWING NO.:DATE:BYDESCRIPTIONDATENO.L.P.L.P.C-121-3539JANUARY 20, 202221-3539OWTS.DWGONSITE WASTEWATER TREATMENT SYSTEMP.O. Box 724 EAGLE, CO 81631Tel (970) 390-0307www.LKPEngineering.comGARRISON RESIDENCEMAP~1"=500'SITELOT 7, BLOCK 1, CORDILLERA FILING No. 341435 GORE TRAILEAGLE COUNTY, COLORADOL.P.3/20/20231.UPDATE OWTS WITH REVISEDBUILDING/SITE PLANSEE REVISIONS BOX ↑3/20/2023 Pump Selection for a Pressurized System - Single Family Residence Project 21-3539 Garrison Residence / 1435 Gore Trail, Cordillera Parameters Discharge Assembly Size Transport Length Transport Pipe Class Transport Line Size Distributing Valve Model Max Elevation Lift Manifold Length Manifold Pipe Class Manifold Pipe Size Number of Laterals per Cell Lateral Length Lateral Pipe Class Lateral Pipe Size Orifice Size Orifice Spacing Residual Head Flow Meter 'Add-on' Friction Losses 1.50 31 40 1.50 None 5 10 40 1.25 4 68 40 1.25 1/8 4 5 None 0 inches feet inches feet feet inches feet inches inches feet feet inches feet Calculations Minimum Flow Rate per Orifice Number of Orifices per Zone Total Flow Rate per Zone Number of Laterals per Zone % Flow Differential 1st/Last Orifice Transport Velocity 0.43 72 31.3 4 2.1 4.9 gpm gpm % fps Frictional Head Losses Loss through Discharge Loss in Transport Loss through Valve Loss in Manifold Loss in Laterals Loss through Flowmeter 'Add-on' Friction Losses 2.9 1.8 0.0 0.3 0.3 0.0 0.0 feet feet feet feet feet feet feet Pipe Volumes Vol of Transport Line Vol of Manifold Vol of Laterals per Zone Total Volume 3.3 0.8 21.1 25.2 gals gals gals gals Minimum Pump Requirements Design Flow Rate Total Dynamic Head 31.3 15.3 gpm feet 0 1020304050607080 0 20 40 60 80 100 120 140 160 Net Discharge (gpm) PumpData PF5005 High Head Effluent Pump 50 GPM, 1/2HP 115/230V 1Ø 60Hz, 200/230V 3Ø 60Hz Legend System Curve: Pump Curve: Pump Optimal Range: Operating Point: Design Point: P.O. Box 724, Eagle, CO 81631 Tel. 970-390-0307 www.LKPEngineering.com March 20, 2023 Steve Garrison 122 Berry Place Erie, CO 80516 303-653-2370 (mobile) troutguy5@gmail.com RE: Soil and Site Evaluation OWTS – 4 Bedroom Residence Lot 7, Block 1, Cordillera Filing No. 34 1435 Gore Trail, Edwards Eagle County, Colorado Project No. 21-3539 Dear Steve, On August 4 and 10, 2021, we visited your property on Lot 7, Block 1, Cordillera Filing No. 34, 1435 Gore Trail, Edwards, Eagle County, Colorado. The purpose of our site visits was to select an area on the property for the proposed Soil Treatment Area. During the second site visit, the excavator Jose Gonzales with Blue Monster Services, dug three profile holes. The OWTS is for a proposed 4-bedroom residence, and it will consist of a 1500-gallons, three-compartments concrete septic tank by Valley Precast with an effluent filter, and an Orenco Pump assembly, and the Soil Treatment Area will consist of 68 Quick 4 Plus, Standard Infiltrator Chambers in a bed configuration with a 2-foot sand filter and pressure dosing. The site plan by the architect Greg Macik, Tab Associates, Inc., was used as a basis for the septic system design. Directions to the site from Edwards are as follows: from US Highway- 6 turn left onto Squaw Creek Road, continue for 3.1 miles to Fenno Drive, continue for 3.4 miles, left on Settlers Loop, continue for 0.3 mi, straight to Summit Trail for 0.9 miles left on Gore Trail for 1.5 miles. The lot is on the left (north) side of the road, one lot before the cul-de- sac. ! Preliminary Investigation G Address: 1435 Gore Trail, Edwards, CO 81632. G Legal Description: Lot 7, Block 1, Cordillera Filing No. 34, Eagle County, Colorado. G Existing Structures: There were no existing structures on the lot. G Location of existing and proposed wells on property: There are no wells on the property. It is services by public water. G ECEHD (Eagle County Environmental Health Department) records: There were no old record. The property was vacant. G Topography: The topography of the leachfield site is moderate with an average slope of about 11 percent. Drainage is to the north. Garrison Res- 1435 Gore Trail March 20, 2023 Page 2 of 4 Project 21-3539 P.O. Box 724, Eagle, CO 81631 Tel. 970-390-0307 www.LKPEngineering.com G Soil Data: The profile holes were observed on August 10, 2021. The soil exposed in the profile holes was as follows: Profile Hole #1 0 to 2.0 feet topsoil with roots 2.0 to 8 feet brown, clayey, gravelly sand with cobbles and some boulders No ground water encountered Profile Hole No. 2 0 to 1.0 feet topsoil 1.0 to 2.5 feet blocky clay with cobbles over basalt cobbles and boulders No ground water encountered Profile Hole No. 3 0 to 1.0 feet topsoil roots to 2 feet 2 to 7 feet clayey, gravelly sand with cobbles and some boulders No ground water encountered A soil sample taken from Profile Holes 1 and 3 at 48-inches was classified as Type 3, LTAR = 0.35 gpd/sf with 35% to 65% Rock (>2mm) CLAY LOAM, R-1, Option 1 with 2 feet deep sand filter and pressure distribution. G Location of applicable setbacks in Table 7-1 ! Reconnaissance G Landscape position: The proposed STA will be located, in the Summit/Shoulder Slope Position northwest from the proposed residence (down gradient) G Topography: The topography of the proposed leachfield site is moderate. The rows of infiltrators in the bed will run along the contours. G Vegetation: The vegetation within the proposed leachfield site consisted of grass, aspen and aspen seedling trees. There were also basalt rocks on the surface. The site surrounding the leachfield was similar. G Natural and cultural features: The property is located within the Cordillera Subdivision at The Summit, a residential subdivision in a gated Garrison Res- 1435 Gore Trail March 20, 2023 Page 3 of 4 Project 21-3539 P.O. Box 724, Eagle, CO 81631 Tel. 970-390-0307 www.LKPEngineering.com community, above US Highway 6 and Eagle River, west of Edwards, Eagle County, Colorado. G Current and historic land use: The current use is residential. Prior use was ranching. ! Detailed Soil Investigation G Visual and tactile evaluation of two or more soil profile test pit excavation; Three profile holes were dug, observed, and logged and visual and tactile evaluation test was done. G Percolation tests plus one or more soil profile holes or one or more profile test pit excavations: Three profile holes were observed and logged on August 10, 2021. ! Report and Site Plan G Name, address, telephone number, email address, and credentials and qualification of individual who conducted site evaluation: This site evaluation was completed by Luiza Petrovska, PE, of LKP Engineering, Inc. LKP Engineering, Inc., is located at 67 Robins Egg Lane, Eagle, Colorado. The phone number is 970-390-0307 and Luiza=s email is luiza@lkpeng.com G Dates of preliminary and detailed evaluation: August 10, 2021. G A graphic soil log, to scale: Attached G Setback distances in Table 7-1: G Main House Well Potable water Structure with basement Structure w/o basement PL Lake Surface Water Intermittent Irrigation lateral (old) Septic Tank Tank n/a 10’+ - ~28’ ~120’SPL n/a n/a - STA n/a 25’+ - ~70’ 69’SEPL n/a n/a ~28’ G Setback distances in Table 7-2: Items 1-4, observed. No ground water encountered. G A drawing (to scale) with complete property boundary lines on minimum G of 8.5 x 11" # Label profile test pits/holes # North Arrow # # Graphic scale # Horizontal and vertical reference points of proposed STA # Contours OR slope direction and % slope # Location of any visible or known unsuitable, disturbed, or Garrison Res- 1435 Gore Trail March 20, 2023 Page 4 of 4 Project 21-3539 P.O. Box 724, Eagle, CO 81631 Tel. 970-390-0307 www.LKPEngineering.com compacted soils # The proposed elevation of the infiltrative surface of the STA from benchmark or ground surface G Anticipated construction related issues: Large, basalt boulders G Assessment of known or foreseeable land use changes expected to affect the system performance: None known. G Narrative explaining difficulties encountered during site evaluation: none The graphic soil log is appended to this report. LKP Engineering, Inc. Luiza Petrovska, PE Enclosure J:\_WP X4-LKP\_2021\21-3539SOIL-SITE-EVAL-BED-PRESS-SAND.DOCX 3/20/2023 Plant 102_01202-Eagle Basic Quality Statistical Summary Report Sieve/Test SpecificationAverageSt DevTests Product 14111-Gypsum 1/4" Concrete Sand Target Specification CDOT Fine Aggregate Period 06/12/2023 - 07/12/2023 1/2" (12.5mm)100 0.47 3/8" (9.5mm)100 0.4 100-1007 #4 (4.75mm)99 0.8 95-1007 #8 (2.36mm)92 3.5 80-1007 #16 (1.18mm)73 4.6 50-857 #30 (.6mm)46 3.7 25-607 #50 (.3mm)18 2.1 10-307 #100 (.15mm)4 1.4 2-107 #200 (75µm)2.2 0.97 0-37 Pan 0.0 0.007 1Page:of 2CRH Americas Materials (AMAT)StonemontQC 07/12/2023 Query Query Selections Date Created 07/12/2023 Date Range 06/12/2023 - 07/12/2023 Plant Eagle 2Page:of 2CRH Americas Materials (AMAT)StonemontQC 07/12/2023 11/15/23, 9:09 AM Cliver bed sand.jpg https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:08 AM bldg swr out.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:09 AM Cliver flushing assembly covers.jpg https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:09 AM IMG_6176Sand.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:09 AM IMG_6900bldg swr.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:09 AM IMG_6901clenout.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:10 AM IMG_6902Septic Tank.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:11 AM IMG_6903STA.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:11 AM IMG_6906End Manifold.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:11 AM IMG_6910Bldg Swr line.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:11 AM IMG_6914Flushing Assemblies.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:11 AM IMG_6937flushing assemblies.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1 11/15/23, 9:11 AM IMG_7031OWTS.JPG https://mail.google.com/mail/u/0/#all/FMfcgzGwHfrfhLMqHGBnLBqZHsSplxWP?projector=1&messagePartId=0.4 1/1