HomeMy WebLinkAboutVail Mtn Chair 11 - 210117300006INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1813-98 BP NO.
OWNER:_U.S.F.S./ VAIL ASSOCIATES, DOUG WORKMAN, CONTACT PHONE: 479-3178
MAILING ADDRESS: P.O. BOX 7, VAIL, CO 81658
APPLICANT: LUIZA PETROVSKA, LKP ENGINEERING PHONE: 970-926-9088
SYSTEM LOCATION: VAIL MT. BOTTOM OF CHAIR LIFT #11 TAX PARCEL NO.
LICENSED INSTALLER: WATER SYSTEM OPERATIONS. JEFFREY ROBISON LICENSE NO. 56-98 PHONE: 970-949-0975
DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
DEVAP 2000 SYSTEM, WITH A HOLDING TANK CAPACITY OF 1518 GALLONS
1000 GALLON SEPTIC TANK 219 SQUARE FEET OF ABSORPTION AREA VIA 8 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN.
SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN REVISION DATED 10/6/98. ENGINEER IS RESPONSIBLE FOR FINAL INSPEC-
TION. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS RECEIVED FINAL APPROVAL
ENVIRONMENTAL HEALTH APPROVAL: DATE: OCTOBER 22, 1998
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL
THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET (VIA )
INSTALLED TANK: GALLONS IS LOCATED DEGREES AND FEET FROM
COMMENTS:
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN
WORK IS COMPLETED.
ENVIRONMENTAL HEALTH APPROVAL DATE:
lete Applications Will NOT Be Accepted
Plan MUST be` attached)
ISDS Permit tk
Building Permit #
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OPPICE - EAGLE COUNTY
P. 0. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
:>>:`*'+�*�,k*,F,t*k��rkk.rx•**�**�cit**rcYrkt**t*�wY�xYrirtt�c,rk•�7ki�tkt:P�**•k*ic•k*,tk**�ki•*
APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 �
MAKE ALL REMITTANCE, PAYABLE TO: "EAGLE COUNTY TREASURER
;TY OWNER: U.S.F.S. Under permit with Vail Associates
IN".7 ADDRESS: P•0. Box 7, Vail, CO 81658 PHONE: 479-3178
:c-:ANT/CON'I'AC'1' PER50N: Luiza Petrovska; .LKP Engineer
926-9088
...-Sc:D SYSTEMS CONTRACTOR: ]1pug Workman PHONE: 479-3178
:':=.,a`!Y/D$A:Mrn�ntai serv;.ps ADDRESS: P.O. Box 7, Vail, CO 81658
..-.•xt����kk*�r*�•**�***t*******ic��c*k**�**t*,r,�,���k**�*x•**�•��t*�t�k�c*Y��;t*******
' APPLICATION IS FOR: (X) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
:'1' OF PROPOSED INDIVIDUAL, SEWAGE DISPOSAL SYSTEM:
-egal Description:
Parcel Number: Trot Size:
ysical Address: VAil Ski Area- Bottom of Chair 11
.'G TYPE- (Check applicable category)
? !esid.en.tial/Single Family Number of Bedrooms
Residential/Multi-Family* Number of Bedrooms
..X) Comme.rcial/Industrial* Type
?PATER SUPPLY: (Check applicable category)
Well ( ) spring { ) Surface
Public Name of Supplier: basis
systems requi design by a Registered Professional Engineer
Date:
,xx;{••h*icic**dF�k•k***iric #�t$ itr,ryk�YtK�t*vcic�F*ic�tft*•4�Ie4rt�k1Y'7�'�1k3t*�c•k*�tic�c�Fic�lrir�tr�l'*ikl�c�r�r*it�F•k
'PAID: RECEIPT ;9: [16 qj,k DATq
CHECK # :, CASHIER
LKP Engineering, Inc.
August 10, 1998
Mr. Ray Merry
Eagle County Environmental Health Division
P.O. Box 179
Eagle, CO 81631
RE: ISDS Application, Chair 11, Vail Ski Resort
Eagle County, Colorado
Project No. 98124
Dear Ray:
We are submitting the application for the septic system at Bottom of Chair 11, on the Vail Mountain
Ski Resort, Eagle County, Colorado. The system will service public restrooms. Mountain Services of Vail
Associates is proposing to construct restrooms near the bottom of Chair 11. The effluent from the restrooms
will be treated by the Devap 2000 system. The system is odorless and waterless process. It reduces the human
waste and evaporates the liquid waste. The remaining solids are emptied at the end of the ski season when the
access roads are passable.
This system has been used successfully in the White River National Forest and Jackson Hole for
number of years. Also, this system has been in service, for two years, on the Vail Mountain at Chair 2. All of
the above systems have similar high uses by skiers, and are located on high elevation areas.
hi addition, the proposed system for Chair 11, will have a 2000 gallon septic tank for a possible high
use overflow of liquids not evaporated by the system either due to malfunction of the system or surge in use.
Also, part of the constructed system will be a 1000 gallon tank for the waste water from hand washing. The
water for hand washing will be hauled to the restrooms on daily basis. At 5 oz. per hand washing, the 1000-
gallon tank will provide storage for water from 178 hand washes per day for 150 days. This tank will also be
pumped out at the end of the ski season.
If you have any quggggp, . please do not hesitate to call.
Sincerely,
LKP Enp-i
�uiza Petrovska,
President
Enclosure
29526
_W
L
cc: Mr. Doug Workman, fax: 479-3123
C:\OFFICE\W PWIN\WPDOCS\98124S l 1. WPD
P.O. Box 2837, Edwards, Colorado 81632 • (970) 926-9088 Tel 9 (970) 926-9089 Fax
TOILETS
DEVAP 2000 SYSTEM
HAND WASHING SINKS
CIVIL/GEOTECHNICAL
LKP " Engineering, Inc.
P.O. Box 2837 Edwards, CO 81632
tel (970) 926-9088 fax (970) 926-9089
2000 GALLON HOLDING TANK
1000 GALLON HOLDING TANK
SEPTIC SYSTEM LAYOUT
BOTTOM OF CHAIR 11
VAIL MOUNTAIN
EAGLE COUNTY, COLORADO
PREPARED FOR:
VAIL ASSO CIA TES
PROJECT NO.:
98124
SCALE:
N. T.S.
DATE:
08-10-98
DRA IMNG NO.:
I
Community Development Department
(970) 328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY, COLORADO
Date: October 22, 1998
TO: Water System Operations
FROM: Environmental Health Division
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Issuance of Individual Sewage Disposal System Permit No. 1813-98. Tax Parcel
# 2101-213-00-008. Property Location: Vail Ski area, bottom of Chair Lift # 11.
Enclosed is your ISDS Permit No. 1812-98. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation. site. Any changes in plans or specifications
invalidates the permit unless otherwise approved.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Your TCO will not be issued until our office
receives this certification.
Permit specifications are minimum, requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
LKP Engineering, Luiza Petrovska
U Engineering, Inc.
October 6, 1998
Mr. Ray Merry
Eagle County Environmental Health Division
P.O. Box 179
Eagle, CO 81631
RE: Amendment to the ISDS Application, Chair 11, Vail Ski Resort
Eagle County, Colorado
Project No. 98124
Dear Ray:
We are resubmitting the application for the septic system at Chair 11, on the Vail Mountain Ski
Resort, Eagle County, Colorado. The system will service public restrooms. Mountain Services of Vail
Associates is proposing to construct restrooms near the top of Chair 11. The effluent from the restrooms
will be treated by the Devap 2000 system. The system is odorless and waterless process. It reduces the
human waste and evaporates the liquid waste. The remaining solids are emptied at the end of the ski season
when the access roads are passable.
In addition, the proposed system for Chair 11, will have a 1000 gallon septic tank for a possible
high use overflow of liquids not evaporated by the system either due to a malfunction of the system or
surge in use, and for the waste water from hand washing. The effluent from the tank will be treated by soil
absorption as shown in the attached report.
If you have any questions please do not hesitate to call.
Sincerely,
LKP Engineeri:
uiza Petrovsk
President
Enclosure
cc: Mr. Doug Workman, fax: 47973123
CA0FFICE\WPWMWPD0CS\98124S 1 I. WPD
P.O. Box 2837, Edwards, Colorado 81632 9 (970) 926-9088 Tel • (970) 926-9089 Fax
LKI'T Engineering, Inc.
SEPTIC SYSTEM APPLICATION
FOR
TOP OF CHAIR 11 RESTROOMS
VAIL SKI AREA
EAGLE COUNTY, COLORADO
PROJECT NO. 98124
OCTOBER 6,1998
R
o •
29526
IA1
PREPARED FOR:
MR. DOUG WORKMAN
VAIL ASSOCIATES, INC.
P.O. BOX 7
VAIL, CO 81658
P.O. Box 2837, Edwards, Colorado 81632 • (970) 926-9088 Tel • (970) 926-9089 Fax
INTRODUCTION
Vail Associates is proposing to replace the existing septic system at the Vail Ski Area
located at Top of Chair 11, with 2 (two) new Devap Systems. The existing septic system was
designed for less than 100 or so flushes per day. Peak days have started to reach the capacity of
the existing system.
The Devap System is a waste conversion and reduction system that is an odorless,
waterless process that uses no chemicals to reduce human waste. Liquid waste is evaporated.
Sinks for hand washing are proposed which will bypass the Devap System and be directed into a
standard septic system. Each Devap System can handle up to 150 uses per day, so the 2 systems
can handle up to 300 flushes per day. On peak days where use exceeds 300 flushes, overflow
from the system is proposed to go to a septic tank (same tank as used for hand washing) and then
to an absorption field.
DESIGN FLOW
A. Restrooms
The Devap System does not use water to flush toilets. The restrooms are to be open to the
public (using the ski area). I have contacted Alex Raycheck who sells the Devap System (1-800-
524-1097) to inquire on sizing and system capacity. Based on his experience with systems
installed in areas of similar elevations and uses, and systems installed in the Vail Ski Area, the
following assumptions have been made in the design:
Peak Number of Uses Expected: 500 uses
Capacity of 2 Devap Systems: 200 uses
Excess Above Capacity: 300 uses
200 uses per day = 12 gallons of effluent. To be conservative assume 30 gpd.
B. Hand Washing
The hand washing sinks are to be push-button, low -flow type. They are 5 ounce valve
sinks that provide for approximately 1000 hand washes per day. The water for the hand washing
sinks is to be supplied from a 74-gallon tank to be filled daily (or piped from a tank at PHQ)
500 uses per day @ 5 ounces per use = 2500 ounces — 20 gallons
To be conservative use 75 gallons.
Average Daily Flow Qavg = 30 gpd from overflow + 75 gpd from hand washing
Qavg = 105 gpd
Qmax = 105 gpd x 150%
Qmax =158 gpd
LKP Engineering, Inc.
SOIL PROFILE AND PERCOLATION TEST
One, 8 feet deep soil profile hole and three percolation holes were excavated within the
proposed leachfield area as shown on the location sketch. The soil profile consisted of one foot
of topsoil over 7 feet ofgrayish-brown, sandy_grav_el_witb wobbles and b_oulders_The percolation
holes were dug and presoaked on September 7, and we ran the tests on September 8, 1998. The
average percolation rate recommended for design is 20Tm_inutes per inch-.
ABSORPTION AREA
A = Qmax/5✓20 = 158gpd/5✓20 = 141square_feet
Compare with Long Term Acceptance Rate of 0.72 gpd/sf
A=158/0.72=219 square feet_- more conservative
50% reduction for Infiltrators in a trench configuration
A=110 square feet
Allowed area of one Infiltrator for design = 15.5 square feet.
Usk�iiltrators in two trenches with four infiltrators each. The two trenches with infiltrators
willnnected with serial distribution.
LIMITATIONS
This report has been prepared according to locally accepted professional engineering
standards for similar methods of testing and soil conditions at this time. There is no other
warranty either expressed or implied.
Sincerely,
LKP ENGINEERING,
Luiza Petrovska, PE
President
Enclosure
C:\0FFICE\WPVWWPD0CS\98124V 11.RPT
29526 ; ¢
oWAL
LKP Engineering, Inc.
-Mwu
9750
_J.
_J
l
♦
♦
PROFILE HOLE♦�
Serial Standard Infiltrator
�♦ Distribution See De if `♦
P-2 Insp ion Par TO
Ieanout `♦ TOp
` P-3 ♦♦
® New Restrooms \
`'P-1 ;; (2 Devap Systems) ♦♦
and Hand Washing \
\ ` ` EXIS77NG
`♦� RESTROOMS
` DEMO
1000 gallon concrete \`♦
septic tank `♦�
♦
♦
NOTE: SITE PLAN DIGITIZED FROM ♦♦\
SITE MAP PROVIDED BY V.A. \
CIVIL/G60TSCHNICAL
LKP Engineering, Inc.
P.O. Box 2837 Edwards, CO 81632
tel (970) 926-9088 fox (970) 926-9089
SEPTIC SYSTEM LOCATION
CHAIR It RESIROOMS
VAIL SKI AREA
EAGLE COUNTY, COLORADO
PREPARED FOR:
VAIL ASSOCIATES
98124
SCALE: — 1„ = 50,
DALE: 10— 05— 98
ORAWNC Na:
TOILETS
0---�-�
DEVAP 2000 SYSTEM
HAND WASHING SINKS
1000GALLON CONCRETE SEPTIC TANK
BY COPLAND CONCRETE OR EQUIVALENT
4--
8'-4"
F------------ir--------i
I II 1
I II I
I II I
I II I
I II I
I II I
I II I
I I I 1 6'-6"
I II I
I II I
I II I
I II I
I II I
I II I
I II I
I II I
L------------ JL-------- i
TOP VIEW
SIDE VIEW
CIVIL/GEOTECHNICAL
LKP Engineering, Inc.
P.O. Box 2837 Edwards, CO 81632
tel (970) 926-9088 fax (970) 926-9089
90' ELBOW
1000 GALLON TWO COMPARTMENT
CONCRETE SEPTIC TANK
GROUND SURFACE
90' ELBOW
22-1/2 'ELBOW
INFILTRATOR CHAMBER
DETAIL A - A
N. T. S.
�_IIIIIIIIII
SEPTIC SYSTEM DESIGN
CHAIR It RESIROOMS
VAIL SKI AREA
EAGLE COUNTY, COLORADO
PREPARED FOR:
VAIL ASSOCIATES
98124
SCALE: N. T.S.
DATE 10-06-98
DRAINNC Na:
2
NO TES
1. The building sewer line from the house to the septic
tank shall have a. maximum slope of 114 inch per foot.
Bends in the building sewer shall be limited to 45
degrees.
2. The septic tank shall be installed level. The tank
shall have removable covers or manholes to within 8
inches of the finished grade, for inspection and cleaning.
J. Excavate three (3) feet wide trenches. The
horizontal distance from side wall to side wall between the
trenches shall be a minimum of six (6) feet.
4. The bottom and the sidewalls of the trenches shall
be raked to eliminate smearing.
5. Assemble and install the Infiltrator Chambers in the
trenches according to the manufacturers
recommendations.
6. Backfill the sidewall area with native on —site soil for
proper support.
7. Back fill the trenches with a minimum of 12 inches
of tamped soil cover.
8. Avoid vehicle traffic over the system.
9. All installations shall meet the rules and regulations
of the Eagle County En vironmen tal Health Division,
Chapter 4, Individual Sewage Disposal Systems.
10. The Septic System Installation shall be inspected by
the Design Engineer prior to backfilling.
CIVIL/GBOT6CHNICAL
LKP Engineering, Inc.
P.O. Box 2837 Edwards, CO 81632
tel (970) 926-9088 fax (970) 926-9089
SEPTIC SYSTEM DESIGN
CHAIR It RESIROOMS
VAIL SKI AREA
EAGLE COUNTY, COLORADO
PREPARED FOR:
VAIL ASSOCIATES
98124
SCALE." N. T. S.
DAIF: 10- 06- 98
ORAWNG Na:
3
LKP ENGINEERING, INC.
P.O. Box 2837
Edwards, CO 81632-2837
(970) 926-9088
Fax (970) 926-9089
PERCOLATION TEST RESULTS
Location: Bottom of Chair 11 Client: Doug Workman
Vail Mountain Mountain Services,
Vail Associates
P.O. Box 7
Vail, CO 81658
Project No.: 98-124
P-1
P-2
P-3
TIME/DEPTH
2O-12/16"
25"
20-4/16"
10
2-12/16"
4-12/16"
6-8/16"
10
4-6/16"
1-10/16"
8-8/16"
3-12/16"
7-6/16"
14/16"
10
5-6/16"
1"
10-14/16"
2-6/16"
8"
10/16"
10
6-6/16"
1"
12-14/16"
2"
8-8/16"
8/16"
10
6-14/16"
8/16"
14-4/16"
1-6/16"
9"
8/16"
10
7-6/16"
8/16"
15-10/16"
1-6/16"
9-8/16"
8/16"
10
7-14/16"
8/16"
17"
1-6/16"
PERC RATE
20 MIN/INCH
7 MIN/INCH
20 MIN/INCH
AVG PERC
20 MINUTES PER INCH
Average Percolation Hole Diameter: 13 Inches
Holes Dug and Presoaked: Septmber 7, 1998
Test Run: September 8, 1998
on
M11 (PATROL HEADQUARTERS)
-3,4 Om 11,250' 3 J
ELEVATION 11,2&_=3,420m_" o, f 1'
�te
64.j
big " W--q
7 N.
Express Lift Mirlift
C--m Downloading Lift w Surface Lift
Most Difficult Area Boundaryf,
Closure (do not cross]
More Difficult n,
Road or Catwalk.,*
(may include flat:,
Easiest W'
terrain) q
0
Nordic r- - 4
Sn ard Zone i
Snowshoe ir
O' Slow Zone P
Parkractic6,
andTrall
Ii
Accessible Facility,
P.
W101heelchair Available", r/7. P.
icnic Area: f.,
Zi-Goest Information
Center Dinn
ketail/Rienta! Table Service
__Dining A;D
SkiSchoo _J1
Rossignol, —
International—: -0-
i0tive Skiing
Test Center
Office
------- Sunday Services
Recreational
Ski Racing
B'us Sto %%El
P -7
dt�- SKE-COLOGY (every
10 minutei)—
**414
_S1% Pick up a Children's Adventure Map of any Ski School location
for more information on the following,
IThildren's Skiing Children's
Centers Adventures
I M!41�09,q
4z Vail`mciuniain-facilities, operated by Vail Associates, Inc., are
E
4
kn e�)• .�]'>tR'I,�,;/ CHUTES - \.\GL, ��
■_, - -L
a
'1,40'tf A
ZINK.
L %Lo
GIROAD
"o) 't.", W 10 ;111�' RA /00",
1813-98 Tax #a/6l-XI3-00-0OW
JOB NAME Bottom of Chair 11 USFS/VA JOB NO.
Devap system for restroom
Vail Mountain
OB LOCATION
BILL TO
DATE STARTED /
g13
DATE COMPLETED
DATE BILLED
disigy o ;-sJgf-
Lr,-'t°
2� 9� C l<d
s4e'11
be jgtm;dp 14
1407AA-y I
Id Z/
/a l q� 09 t-b issue ,
1 oho
F ZIP �f Z a
absor �� P� t"A 8 I.017-P Iryr A r
d v" >� DG P
av
s .