HomeMy WebLinkAbout346 Jackman Ranch Rd - 210507301005INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1802-98 BP NO. 12112
OWNER: STAN & MARY ELLEN COPE PHONE: 970-926-3535
MAILING ADDRESS: P.O. BOX 1166, EDWARDS, CO 81632
APPLICANT: SAME PHONE:
SYSTEM LOCATION: 346 JACKMAN RANCH RD., EDWARDS, CO TAX PARCEL NO. 2105-073-01-005
LICENSED INSTALLER: GROSS EXCAVATING, LANCE GROSS LICENSE NO. 63-98 PHONE: 970-268-5701
DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-827-9088
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
1000 GALLON SEPTIC TANK 1125 SQUARE FEET OF ABSORPTION AREA VIA 37 INFILTRATOR UNITS AS PER DESIGN.
SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 7/6/98. ENGINEER IS RESPOSIBLE FOR FINAL INSPECTION. DO
NOT BACK FILL ANY PORTION OF THE INSTALLATION UNTIL THE INSPECTION HAS BEEN COMPLETED. BUILDING CERTIFICATE OF
OCCUPANCY WILL NOT BE ISSUED UNTIL SEPTIC SYSTEM HAS BEEN APPROVED.
ENVIRONMENTAL HEALTH APPROVAL DATE: OCTOBER 15, 1999
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL
THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 1 1 1 6 SQUARE FEET (VIA -16 TNFTT,TRAT01R 1JNTTq )
INSTALLED CONCRETE SEPTICTANK: 1000 GALLONS IS LOCATED _ DEGREES AND 18 FEET AND INCHES
FROM THE CLEANOUT ON THE SOUTH SIDE OF THE HOUSE.
COMMENTS: ENGINEER FINAL CERTIFICATION RFCETVFD QCTOBFR 27, 1999
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN
WORK IS COMPLETED. //����� �j�j��e® �, Gj
ENVIRONMENTAL HEALTH APPROVA(jd4jAd V QI DATE:
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1802-98 B O. 12112
OWNER: STAN & MARY ELLEN COPE PHONE: 9Z26-3535
MAILING ADDRESS: P.O. BOX 1166 EDWARDS CO 81632
APPLICANT: SAME PHONE:
SYSTEM LOCATION: 346 JACKMAN RANCH RD., EDWARDS CO TAX PARCEL NO. 2105-073-01-005
LICENSED INSTALLER: GPHIR EXCAVATING CARSON REID ZZ LICENSE NO. 26-98 PHONE: 970-926-2409
DESIGN ENGINEER: LKP ENGINEERING LUIZA PETROVS PHONE NO. 970-827-9088
INSTALLATION HEREBY GRANTED FOR THE FOLLO G:
1000 GALLON SEPTIC TANK 1125 SQUARE FE OF ABSORPTION AREA VIA 37 INFILTRATOR UNITS AS PER DESIGN.
SPECIAL REQUIREMENTS: INSTALL ASP ENGINEER'S DESIGN DATED 7/6/98. ENGINEER IS RESPOSIBLE FOR FINAL INSPECTION.
BUILDING CERTIFICATE OF OCCUP CY WILL NOT BE ISSUED UNTIL SEPTIC SYSTEM HAS BEEN APPROVED.
ENVIRONMENTAL HEALT APPROVAL: f/V (� �WY DATE: JULY 13, 1998
CONDITIONS:
1. ALL INS T ATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTE URSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS P IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
RE MENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
S L AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3 HAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL
THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET (VIA )
INSTALLED TANK: GALLONS IS LOCATED _ DEGREES AND _ FEET FROM
COMMENTS:
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN
WORK IS COMPLETED.
ENVIRONMENTAL HEALTH APPROVAL DATE:
Inuomplete'Applications Will NOT Be Accepted
(Site Plan MUST be attached)
ISDS Permit # U
Building Permit
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE.— EAGLE COUNTY
P. O. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (Basalt)
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
* MAKE ALL REMITTANCE PAYABLE'.TO: "EAGLE COUNTY TREASURER"
PROPERTY OWNER:
MAILING ADDRESS:
PHONE: 7a6
APPLICANT/ CONTACT PERSON : PHONE:
LICENSED SYSTEMS CONTRACTOR: 04-son P_ e , PHONE: 9a
COMPANY / DBA : b h I �>c� is7� n �. ADDRESS:
**************************************************************************
PERMIT APPLICATION IS FOR: 04 NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description:
t-i� �I�` 3 La_�
Tax Parcel Number:
021 05 ._o� '� 0%-�7�
S� Lot Size: 3/ �ri-CAD,4__)
Physical Address:
aa-d(l an RCdinCSl
ko-p
, F-d Co it -
BUILDING TYPE:. (Check applicable category)
.) Residential/Single Family Number of Bedrooms
j Residential/Multi-Family* Number of Bedrooms
( ) Commercial/Industrial* Type
TYPE OF WATER SUPPLY: (Check applicable category)
( ) Well ( ) Spring ( ) Surface /
(Public Name of Supplier:IT _
*These systems require design by a
SIGNATURE: IV -VA 2X
************** **** * ***********
Registered Professional En77ineFr
(7 Date: 1,4
AMOUNT PAID: 15� RECEIPT #: I love DATE: ID . -
CHECK CASHIER:
LKP ENGINEERING, INC.
P.O. Box 2837
Edwards, CO 81632-2837
(970) 827-9088
Fax (970) 827-9089
PERCOLATION TEST RESULTS
Location: L of 5, Block 3, Lake Creek Meadows Client: ]Michael L. Sanner, AIA
E gle County, Colorado Address: P.O Box 1498
Project No.1: 98102 Edwards, CO 81632
P-1
P-2
P-3
TIN E/DEPT
29"
29-6/16"
26-8/16"
10
28-2/16"-add
water 3-4/16
1-2/16" ***
19-10/16"
1-12/16"
20-9/16"
4"
10
12-8/16"
9-4/16"
21"
6/16"
21-10/16"
1-1/16"
10
18-7/16"-15/16"
22"
10/16"
22"
6/16"
10
22"
3-9/16"
23"
V
22-6/16"
6/16"
10
24-8/16"
2-8/16"
24"
1"
22-12/16"
6/16"
10
26-8/16"
2"
25"
1"
23-2/16"
6/16"
10
28"
1-8/16"
26"
1"
23-8/16"
6/16"
PERC RAT
8.91411NJTNCH
10 ?vliN/INCH
26.6 MIN/INCH
AVG PER
20 MINUTES PER INCH
*** The slow4t rate recorded was used instead of the average
Average Perco i,ation Hole Diameter: 6 Inches
Holes Dug and Presoaked: July 2, 1998
Test Run: July 3, 1998
ivr t.+-.r iJJJ ti. LT
J(V JLV JVVJ
Lrl%r GIVL711`IF_F_Mj YVI, LI`Ra
rMUL U1
Enginccring)-inc.
OVIUCE9MCMCAL
October 26, 1999
Mr. Michael Satnncr
P-0. Box 1498
Edwards, CO 81632
Dear Mike:
RE:110,0eetion 4f Septic System Installation
Lot 5, .$lock 3, Lake Creek Meadows
Eagle County, Colorado
Projeeit�No. 98102 - Permit No.1802-98
At the request of Lance Grross frohi Gross Excavatir . pn October 15, 1999, we visited the
constr,rction site on Lvt 5, �locit 3, bake Creek Meadows- agle Cduaty, Colorado. The purpose of
our site visit was to observe the installation of the septic systir .
They installed the systertl in overall compliance with-.tite septie system design, Drawing No.
98102 D.DWQ, dated July 6, 1998. The °system was installed. as shown on the above -named drawing.
'They installed I000-gallon, two compare tints, a precast, concrete septic tank. The tank had 3-1211 risers
oil the access openings. From the house to the cleanout was 2 feet anal'ftm the cleanout to the tank was
18 feet. 1, Toro the tank to the first Infiltrat+of trench was 113 feet. One cleanout is to be installed between
the tank and the first infiltrator trench at.tlie angle point in 04,"Jine.
'mirty-six Statidard Infiltfator Ch imbers were instalka in thread trenches with 12 Infiltrators
cacti. The infiltrators were connected with serial distribution.An the last infiltrator of each trench,
impectioi3 ports were installed. HorizoritW.distance from ceW.r to cen r of the trenches, was 9 feet or
snore. All piping was SDR-35, 4-inch PVC. The soil profile I'll.-ihe trenches was conSiStent with the soil
described in the soil profile. From the soditast corner of the east treat h to the property line was 10 feet.
If you have any questions, please do not hesitate to c*11.
5incen
LKPI
u a
Presid
cc: Ms. Heather Savalox, ]Raagle Cov6ty EtnvironmentaV ealth Division, fax: 328-0349
C:�h4yP'tl ecltoreidoclW PPOCS\99 f 4203E. WP4
P.O_ Box 2837, Edwards, CO 81632,.- (970) 9264099 TO," (970) -9089 faux, E-mail: lkpeng snowcap.riet
n T-CC.-1 QQQ TI IC MQ-C'7OM TM-=n(-_1 C fY71 II. 17V Ck 11I U1=r11 TLI nr,r+r.A
Community Development Department
(970) 328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
Date: July 13, 1998
TO: Gophir Excavating
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
FROM: Environmental Health Division
RE: Issuance of Individual Sewage Disposal System Permit No. 1802-98. Tax Parcel
# 2105-073-01-005. Property Location: 346 Jackman Ranch Road, Edwards,
CO., Cope residence.
Enclosed is your ISDS Permit No. 1802-98. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Your TCO will not be issued until our office
receives this certification.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
LKP Engineering, Luiza Petrovska
Community Development Department
(970) 328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY, COLORADO
October 27, 1999
Stan & Mary Ellen Cope
P.O. Box 1166
Edwards, CO 81632
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit #1802-98, Tax Parcel #2105-073-01-005. Property location: 346
JackmanRanch Rd., Edwards, CO.
Dear Mr. & Mrs. Cope:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,
" a (Au ---
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Informational Brochure
Final ISDS Permit
cc: files
1802-98 Tax #2105-073-01-005
JOB, NAME Lot #5, Block 3, COPE
346 Jackman Ranch Rd.
Lake Creek Meadows
JOB No. - / i1a
i ncornnm
•
i
DATE COMPLETED
DATE BILLEDs
. • r l r /
-1 5 �MIA"i
oo . L.iNE WZ
ire. �"Un��o <_ •
I
M-A.4-!,
i
i �' /I �vmw"1111_
1 .1 : _�. •� /i. ,
I. 1 .�
I Lam!_ _ i •
��'
Fill, I IN I %m W ME
+I�
=
. L� i
0 . ' it
anM
�1L �_
TOTAL
_■Ili
_
all
TOTAL MATERIAL:
SINE
or
05
• •
-■
COSTS
SIN■
SIN■
TOTALNEE •_ COST
ENE
GROSSPROFIT
SEE
LESS OVERHEAD %OF SELLING PRICE
FIE�
•
JOB FOLDER Product 277 JOB FOLDER Printed to Ill