HomeMy WebLinkAbout901 Red Canyon Creek Rd - 194125102007 - 1785-98ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1785-98 BP NO. 11962
OWNER: MACK AND NANCY NICHOLS PHONE: 314-878-7668
MAILING ADDRESS: 12300 HALSGAME, CREVE COLUR, MO 83141
APPLICANT: GEORGE SISNEROS PHONE: 970-827-5231
SYSTEM LOCATION: LOT 7, RED CANTON ESTATES TAX PARCEL NO. 1941-251-02-007
LICENSED INSTALLER: EDWARDS EXCAVATING, DON JOHNSON LICENSE NO. 35-98 PHONE: 970-926-3395
DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-827-9088
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
1500 GALLON SEPTIC TANK 1500 SQUARE FEET OF ABSORPTION AREA VIA 48 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN
SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 5/29/98. BE SURE TO MAINTAIN 50 FOOT SETBACK FROM THE
POND. DOUBLE ENCASE AND INSULATE EFFLUENT LINE UNDER STREAM CROSSING ENGINEER IS RESPONSIBLE FOR FINAL INSPEC-
TION. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED WITHOUT SEPTIC SYSTEM APPROVAL
ENVIRONMENTAL HEALTH APPROVAL: DATE: JUNE 4, 1998
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL
THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 1500 SQUARE FEET (VIA 48 INFILTRATOR UNITS' )
INSTALLED CONCRETE TANK: 1500 GALLONS IS LOCATED _DEGREES AND 34 FEET FROM THE MAIN
RESIDENCE.
COMMENTS: FINAL ENGINEER CERTIFICATION RECEIVED — 4— 8, SEF SITF PLAN AND ENGINEER
FINAL LETTER FOR SYSTEM COMPONENTS AND LOCATIONS.
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN
WORK IS COMPLETED.
ENVIRONMENTAL HEALTH APPROVAL 4Z DATE: SEPT. 24, 1998
(t, Ilan MUST be attached)
ISDS Permit #
Building Permit # a -
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. O. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
**************************************************************************
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
*
*
* MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
**************************************************************************
PROPERTY OWNER: I A99 A/C- V JV
i 2- O
MAILING ADDRESS: / " S r,®9%l% L PHONE: �0 -Ciz
.,VG cDlu(E, mo g3iyt
APPLICANT/CONTACT PERSON: GAORGI JoSN5-5 PHONE:
-DOA) jc) j11j S o 1v
LICENSED SYSTEMS CONTRACTOR: r=�� 5 dr PHONE:
COMPANY/DBA: ADDRESS:!�A 0 "g/63Z
PERMIT APPLICATION IS FOR: §<-, NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description: 4 07'17 &9 n��►�,
Tax Parcel Number: /To- '3- (- 0,1- ,
Physical Address 4 O)A,�tu
BUILDING TYPE: (Check applicable cate ry)
(pd Residential/Single Family
( ) Residential/Multi-Family*
( ) Commercial/Industrial*
TYPE OF WATER SUPPLY: (Check applicable category)
()Q Well ( ) Spring ( ) Surface
( ) Public Name of Supplier:
Lot Size: --1/9r_-lCE75;�
D
Number of Bedrooms_
Number of Bedrooms
Type
*These systems require design a Registered Professional Engineer
SIGNATURE: Date:
AMOUNT PAID: /'57) -CV RECEIPT #: 16 %%/ % DATE: 3
CHECK #: CASHIER:
September 24, 1998
Mack and Nancy Nichols
12300 Halsgame
Creve Colur, MO 83151
RE: Final of ISDS Permit #1785-98, Tax Parcel #1941-251-02-007. Property location: 901
Red Canyon Rd., Edwards, CO.
Dear Mr & Mrs. Nichols:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Informational Brochure
Final ISDS Permit
cc: files
Wil 1i/ 1'i'dd 1b: 4d, J eu_U1 l—SaEy LKH ENGINEERING, INC PAGE 01
September 23, 1998
Mr. Steve Ride»
Steve Riden Architects
P.O. Box 3238
Vail, CO 81658
Tear Steve -
RE: Inspection of Septic Systems Installation
Nichols Residence
Lot 7, Red Canyon Estates
Eagle County, Colorado
Project No. 9810 - Permit No. 1785-98
At the request of Rick from Graystone Construction., on July 22 and September 16, 1998, we
visited the construction site on Lot 7, Red. Canyon estates, near Eagle, Eagle County, Colorado. The
purpose of our site visit was to observe the installation of the septic system.
They installed the system in overall compliance with, the septic system design, Drawing No.
981 OSD.DWG, dated May 29, 1998.
The system was connected to the main residence as shown on the above named drawing. From the
house to the first cleanout was 4 feet. From there to the septic tank was 30 feet. They installed 1500-gallon,
two compartments, a precast, concrete septic tank. The tank had Moot risers on both'iinspection covers.
From the tank to the stream crossing was 80 feet and from the stream crossing to the cleanout was 30 feet.
We recommended installation of an additional cleanout on the west side of the stream crossing. At the
stream crossing the 4-inch sewer line was encased in an 8-inch PVC pipe. From the crossing to the edge of
the pond was 105 feet. From the east cleanout the line turned at 45 degrees for 52 feet and 22 degrees for 8
feet to the next cleanout. From the cleanout to the first Infiltrator trench was 62 feet. Also, from the first
infiltrator trench to the edge of the pond was 75 feet.
Forty-eight Standard Infiltrator Chambers were installed in four trenches with 12 Infiltrators each.
The infiltrators were connected with serial distribution. In the first and last infiltrator of each trench,
inspections ports were installed. Horizontal distance from center to center of the trenches, was 9 feet or
more. All piping was SDR-35, 4-inch PVC, The depth of the trenches was two to three feet. The soil
profile in the trenches was consistent with the soil exposed in the profile hole.
If you have any questions, please do not hesitate to call.
Sincerely,
UP Enginee,
Luiza Petrovsk
President
cc: Ms. Heather Savalox, Eagle County Environmental Health. Division, fax: 328-7185
�"MNW.RwINr*ws1OFF7CZWPWIMWPDOCWBtQOSI.wry
P.O. Box 2837, Edwards, Colorado 81632 * (970) 926 9088 Tel • (970) 926-9089 Fax
1785-98 Tax# 1941-251-02-007
�O*�JOB
° Lot #7, Red Canyon Estates NICHOLS
NAME, Red Canyon Rd., Wolcott go JOB NO. I I k a'
LOCATION
BILL TO
DATE S7ARTE
DATE COMPLETED
DATE BILLED
Ly
g
/zp C G 9S fyTo
k l 00 j. 2� a- o f ;,�
03
?6 ok
to
wee
fis
JOB COST SUMMARY
K
�
s
l�
tl
k
- - - -
d
Gi
O
it
TOTAL SELLING PRICE
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 277 JOB FOLDER
Printed in U.S.A.