HomeMy WebLinkAbout780 Siloam Spring Dr - 211501401001LKP Engineering, Inc. S CMUGEOTECHNICAL May 10, 2017 Lolis and Melvin Sandoval P.O. Box 9514 Avon, CO 81620 email: madoch78&hotmail.com Dear Lolis and Melvin: RE: Inspection of Septic System Installation - Sandoval Residence Lot 1, Siloam Springs PUD 0780 Siloam Springs Road Dotsero, Eagle County, Colorado Project No. 15-3037-OWTS-12-15-13875 At the request of Kenny Williams, your installer, on October 14 and November 5, 2016, we visited the construction site for your residence under construction on Lot 1, Siloam Springs PUD, 0780 Siloam Springs Road, Dotsero, Eagle County, Colorado. The purpose of our site visits was to inspect the installation of the septic system. They installed the system in overall compliance with the septic system design, Drawing No. 15-3037OWTS-Elim.dwg, last revised April 15, 2016, and as shown on the attached as -built sketch. They installed a 1500-gallons, two compartments, plastic septic tank by Infiltrator and an Eliminite Tanc 120C, also in a 1500-gallons, two compartments, plastic, septic tank by Infiltrator. The septic tanks had three access openings on each. On each of the first and last openings, 18-inch, plastic risers were constructed. A cleanout was constructed between the septic tank and the building, as shown on the above -named as -built sketch.. Ninety-eight (98), Q-4, Plus Standard Low Profile Infiltrator Chambers were installed in six (6) trenches. There were eighteen (18) infiltrators in the first trench, seventeen (17) in each of the next four (4) trenches, and twelve (12) in the last trench. There was a minimum of six feet separation between the trenches. In the first and last infiltrator of each trench, quick4plus, standard all -in -one 8-inch end caps were installed. The inspection ports were not installed at the time of our first site visit but were observed during the second site visit, after the leachfield was already backfilled. A wooden post for the control panel was constructed west of the Eliminite tank. The system was tested and put into operation by your installer, the Eliminite representative and maintenance provider, Kenny Williams. He will be supplying a letter of the system start up. There is no other warranty either expressed or implied. „ 'I'lliN,11 If you have any questions, please do not hesitate to call o R EGIs Sincerely, LKP Engineering, Inc. -v ; 29526 Z-07 J-4• •W` i ►e Luiza Petrovska, PE '��,�, ....�V . cc: Eagle County Environmental Health Department, E-mail: Terri.Vroman(a),ea leg coup , .us J:\-WP X4-LKP\_2015\15-30370SIELIMQ4PLUSLP.DOCX P.O. Box 724, Eagle, CO 81631 Tel. (970) 390-0307 5-8-2017 K.W.'S Pigefisation t Environmental Health To Whom it may concern: On March 25'hof 2017 the Eliminite on site waste system located at 780 Siloam Springs Drive in Dotsero CO. Was activated by Kenneth Williams From K.W.'S Pipefixation Who is Eliminite certified. Upon startup of the Eliminite it was observed that the system consists of a SJE-Rhombus control panel, Serial# I 39818X- 16223, one Drain field pump, one Eliminite pump both 120 volt, a 1500 Gal primary septic tank And a 1500 Gal Eliminite tank. All components of the system functioned as designed. If there are any concerns about the startup of this system feel free to contact K.W.'S Pipefixatin. Sincerely Kenneth Williams LKP: Engineering, Inc. CIVIL/GEOTECHNICAL I ��G 4-INCH DIAMETER, SDR35 PIPE, SERIAL DISTRIBUTION I I 1 INSPECTION IPORT (TYPICAL)` END CAP (TYP) I� CP I I I I I I I I I I I I I I I ,"- N g02 g 17 17 PROJECT DESCRIPTION: PROJECT V. FS-BUILT 780 SILOAM SPR NGS DR VE I ISDS PERMIT NO.: 1 1 SKETCH EAGLE COUNTY, COLORADO — OWTS-12-15-13875 1 I SANDOVAL REATE SIDENCE D10-14 and 11-5, 2016 I ' QUICK 4 PLUS STANDARD OW PROFILE INFILTRATOR CHAMBER 18 1 1 I 1 20' OF 2-INCH DIAM. SCH40 PVC PERFORATED 1 AT 10 AND 2 O'CLOCK WITH 1/41NCH HOLES AT I 2-FOOT INTERVALS, SUSPENDED FROM THE TOP WITH TIES WITH ONE HOLE DRILLED AT 1 THE INVERT END OF THE PIPE 1 I /1 ' / 1 / 1 \_- 100' OF 2-INCH DIAM. \� SCH40 PVC EFFLUENT LINE 17 / ELIMINITE TANC 120C, TWO -COMPARTMENT, PRE ASSEMBLED, TREATMENT TANK IN A 1500 GALLONS PLASTIC SEPTIC TANK BY INFILTRATOR 1500-GALLONS, TWO -COMPARTMENT, / PLASTIC, SEPTIC TANK BY INFILTRATOR ri 1 "DIAM. J40 PVC I I \ POST FOR L CONTROL 1 PANEL 10' OF 4-INCH /1 _\ r DIAMETER, SDR35, l� BUILDING SEWER LINE —I CLEANOUT ° I \�2G z 1" SCH40 PVC DENITRIFICATION\0RETURN LINE FROM THE PUMP I ° CHAMBER TO FIRST COMPARTMENT OF THE SEPTIC TANK I� LOT I 15.027 ACRES \ I I _ 1 N8 •12'33"W `— — -- -- -- -- -- — -- P.O. Box 724 Eagle, CO 81631, (970) 390-0307, www.lkpengineering.com pop" je&) - i- /�- ) 3 45-V 5-8-2017 K.W.'S Pipefization P.O.BOX 1740 Gypsum, CO. 81637 Phone: 970-401-3688 i Environmental Health P.O.BOX 179. 500 Broadway Eagle, CO. 81631-0179 Phone: (Type the recipient phone number( ----------------------------------------------- To Whom it may concern: On March 25'' of 2017 the Eliminite on site waste system located at 780 Siloam Springs Drive in Dotsero CO. Was activated by Kenneth Williams From K.W.'S Pipefixation Who is Eliminite certified. Upon startup of the Eliminite it was observed that the system consists of a SJE-Rhombus control panel, Serial# I 39818X- 16223, one Drain field pump, one Eliminite pump both 120 volt, a 1500 Gal primary septic tank And a 1500 Gal Eliminite tank. All components of the system functioned as designed. If there are any concerns about the startup of this system feel free to contact K.W.'S Pipefixatin. Sincerely i Kenneth Williams F �n If L rr 4 A �w r5 l - �■ �..4�C'"� _.. �t U r � a a f Iz MY '� jj-