HomeMy WebLinkAbout150 Casteel Ridge - 210701401016INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631
Telephone:328-8755 t -P lb1576
,5
,
YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. !
Please call for final inspection before covering any portion of installed system.
OWNER: Neil Braverman PHONE: (407) 241-6778
MAILINGADDRESS: 4832 Channel Circle clry: Boca Raton state: FL ZIP:33487
APPLICANT: Eric Meyer, Signature Homes PHONE: (970) 926-4329
SYSTEMLOCATION: 0150 Casteel Ridge, Cordillera TAX PARCEL NUMBER: 2107-014-01-016
LICENSED INSTALLER: StenSon Excavating, Bill StenSon LICENSENo: 27-96
DESIGN ENGINEER OF SYSTEM: Alpine Engineering, Linda Schorr RPE
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
1515 00 GALLON SEPTIC TANK
ABSORPTION AREA REQUIREMENTS:
SQUARE FEET OF SEEPAGE BED 1500 SQUARE FEET OF TRENCH BOTTOM. via 42 infiltrators as per design.
SPECIAL REQUIREMENTS: Install as per engineer's design dated May 1 1996
ENVIRONMENTAL HEALTH APPROVAL: DATE:
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT
TO AUTHORITY GRANTED IN 25- 10. 104. 1973. AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION
TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A
REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED.
FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED
PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 1500 SQUAREFEET. via 42 infiltrator units as per design
INSTALLED SEPTIC TANK: 1500 GALLON 150 DEGREES 18 FEETFROM South West foundation corner
1880 24' from the cleanout
SEPTIC TANK ACCESS TO WITHIN W OF FINAL GRADE AND
PROPER MATERIAL AND ASSEMBLY _X YES _NO
COMPLIANCE WITH COUNTY/STATE REQUIREMENTS: _X YES _NO
ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM 15 MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED.
COMMENTS: RnginPpr final np:prnval received 8— g-9h
ENVIRONMENTAL HEALTH APPROVAL: DATE:August 29,1996
ENVIRONMENTAL HEALTH APPROVAL: DATE:
(RE -INSPECTION IF NECESSARY)
RETAIN WITH RECEIPT RECORDS
APPLICANT / AGENT:
PERMIT FEE PERCOLATION TEST FEE
OWNER:
RECEIPT #
CHECK#
Plan MUST be attached)
W ISDS Permit
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. O. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
**************************************************************************
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
* .-MAKE'ALL REMITTANCE PAYABLE TO: ".EAGLE COUNTY TREASURER"
**************************************************************************
PROPERTY OWNER: �{ PHONE: L Yb3 ) 2.-i/ -117
MAILING ADDRESS: N 3Z sd
APPLICANT/CONTACT PERSON-P4- -eA' PHONE: 0,10)
MAILING ADDRESS: _�°< <�. _ i Lzez2a-
LICENSED ISDS CONTRACTOR: SSo7, iA l-'PHONE: ( )
COMPANY/DBA: ADDRESS:
***************************************************************************
PERMIT APPLICATION IS FOR: ( ) New Installation ( ) Alteration ( ) Repair
***************************************************************************
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
`-
Building Permit # M i K3 (if known)
Legal Description: Subdivision: 6ahAflet'b Filing:LLZBlock: Lot No. _
Tax Parcel Number: :Z c, 7_- r� j Ll - U �- ja .� Lot Size-
Street Address:
BUILDING TYPE: (Check applicable category)
(29 Residential/Single Family Number of Bedrooms 7
( ) Residential%Multi-Family* Number of Bedrooms
( ) Commercial/Industrial* Type
TYPE OF WATER SUPPLY: (Check applicable category)
(� Well ( ) Spring ( ) Surface
( Public Name of Supplier:
*These systems require design by a Registered Professional Engineer
SIGNATURE: iu Date: �/Z -z, 196"^
TO BE
AMOUNT CPAIpET 1 Sl'Y' COUNTYRECEIPT # : i -2 DATE:
CHECK #: CASHIER:,
ISDS Permit # /:�'&— `16
Building Permit # 10 3
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P.O. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (Basalt)
PERAUT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
PROPERTY OWNER: Neal and Jeannie Braverman
MAILING ADDRESS: 4832 Chamal Circle, Boca Raton, FL 33487
PHONE: (407) 241-6778
APPLICANT/CONTACT PERSON: Eric Meyer, Signature Homes, Inc., 926-4329
Linn Schorr, Alpine Engineering, Inc. 926-3373
PHONE:
LICENSED SYSTEMS CONTRACTOR: Stenson Excavating
ADDRESS: PHONE:
PERMIT APPLICATION IS FOR: (X) NEW CONSTRUCTION () ALTERATION () REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description:
Parcel Number: Lot 39, Cordillera Subdivision, Filing 2, Eagle Co., CO
Lot size: 2.543 acres
Physical Address: 0150 Casteel Ridge Road, Eagle County, Colorado
BUILDING TYPE: (Check applicable category)
(X) Residential/Single Family
() Residential/Multi-Family*
() Commercial/Industrial*
Number of Bedrooms 4
Number of Bedrooms
Type
TYPE OF WATER SUPPLY: Well () Spring () Surface ( )
Public (X) Name of Supplier: Squaw Creek Metropolitan District
*These systems require design by a Registered Professional Engineer
NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION
MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
SIGNATURE: DATE:
AMOUNT PAID: RECEIPT # DATE:
CHECK # CASHIER:
Community Development Department
(970) 328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
August 29, 1996
Neil Braverman
4832 Channel Circle
Boca Raton, FL 33487
RE: Final of ISDS Permit No. 1576-96 Parcel #2107-014-01-016.
Property location: 0150 Casteel Ridge, Cordillera, Edwards, CO.
Dear Mr. Braverman:
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance
with any other Eagle County requirements. Also enclosed is a brochure regarding the care of
your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Information Brochure
Final ISDS Permit
cc: files
Community Development Department
(970)328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
M
Date: May 8, 1996
TO: Stenson Excavating
FROM: Environmental Health Division
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 8 163 1 -0179
RE: Issuance of Individual Sewage Disposal System Permit No. 1576-96.
Property Location: 0150 Casteel Ridge, Cordillera, Braverman residence.
Enclosed is your ISDS Permit No. 1576-96. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation site. Any changes in plans or specifications invalidates
the permit unless otherwise approved.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Your TCO will not be issued until our office
receives this certification.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
Alpine Engineering, Linn Schorr, RPE
SEPTIC SYSTEM APPLICATION
LOT 39
Cordillera Subdivision, Filing 2
Braverman Residence
Prepared for: Signature Homes, Inc.
Mr. Eric Meyer
P.O. Box 599
Edwards, CO 81632
Prepared by: Alpine Engineering, Inc.
P.O. Box 97
Edwards, CO 81632
(970) 926-3373
SEPTIC SYSTEM APPLICATION
INTRODUCTION
Lot 39, Cordillera Subdivision, Filing 2 is a single family homesite located in the Squaw
Creek drainage, southwest of Edwards, Eagle County, Colorado. A four -bedroom home is
proposed to be built on the site. The site is not currently served by Upper Eagle Valley
Consolidated Sanitation District; an Individual Sewage Disposal System is proposed.
PROPOSED USE
The proposed system will serve a four -bedroom residential single family dwelling.
QUANTITY OF SEWAGE
(4 Bedrooms)(2 persons/bedroom)(75 gpd)(1.5 peaking factor) = 900 gpd 04--
SEPTIC TANK SIZE
900 gpd x 30 hrs/day = 1,125 gallons (25� ( �U` vvx n
24 hrs/day
Round up to 1,500 gallon capacity tank with baffle. 6-K-
SOILS INVESTIGATION
On April 29, 1996, three percolation tests were performed at the proposed absorption trench
location. Three pits were hand -dug to a depth of two and a half feet, encountering silt with
very little clay to the end of hole. Neither roundwater nor evidence of a seasonal high water
table was encountered in the holes. The average percolation rate was 19 minutes per inch
(MPI). All three tests indicated sufficient percolation rates.
A geotechnical investigation was performed at the site in February 1996. Test borings
conducted at the eastern end of the property indicate var in depths to bedrock (2.5 feet and 8
feet). Soil in the area of the proposed absorption trenches appears to be derived from slope
wash and it has been assumed for design purposes that the depth to bedrock is at least eight
feet. The depth to bedrock will be field -verified during installation of the ISDS system—. - e
system will be installed where indicated with a four -foot separation to bed rock or re -located
to provide four feet of separation.
0
Application for ISDS Permit l Lot 39, Filing 2, Cordillera
TRENCH DESIGN
A = Q/5 (T)o.s
A = (900 gpd/5) (19 mpi)os
A = 785 SF'O'"
Check with loading rate:
For the type of soils found on site, the EPA Design Manual: Onsite Wastewater Treatment
and Disposal Systems recommends a maximum application rate of 0.6 gallons per square foot
per day.
900 d = 1,500 ft2
.6 gal/
This area will be used for design purposes.
With a 50% reduction for infiltrators = 750 SF 6
Number of Infiltrator Units:
750 SF 042 iltrator Units �% /18 SF/Infiltra�J'
Length of Trenches:
42 infiltrator units x 6.25 ft./infiltrator unit = 3 trenches at 87.5 ft. long each
3 trenches
APPLICABLE SETBACKS
The proposed location of the absorption trenches is outside of all applicable setbacks
distances.
Application for ISDS Permit 2 Lot 39, Filing 2, Cordillera
ALPINE ENGINEERING, INC.
Braverman Residence ISDS
Percolation Test Results - 4/29/96
TIME
HOLE #1
HOLE #2
HOLE #3
DEPTH (FT.)l
MPI
DEPTH (FT.)
MPI
DEPTH (FT.)
MPI
10:25
0.50
0.60
0.58
10:30
0.54
10.42
0.64
10.42
0.63
8.33
10:35
0.57
13.89
0.67
13.89
0.68
8.33
10:40
0.60
13.89
0.68
41.67
0.71
13.89
10:45
0.63
13.89
0.69
41.67
0.74
13.89
10:50
0.65
20.83
0.70
41.67
0.77
13.89
10:55
0.68
13.89
0.71
41.67
0.81
10.42
AVERAGE
14.47
31.83
11.46
TABLE 7-2
RECOMMENDED RATES OF WASTEWATER APPLICATION
FOR TRENCH AND BED BOTTOM AREAS (4)(11)(12) (a)
301E TEXTURE .� _ .: .
PERCOLATION RATE
APPLICATION RATE
min/in
gpd/ft (2)
Gravel, coarse sand
<1
Not Suitable (C)
Coarse to medium sand
1-5
1.2
Fine sand, loamy sand
6 -15
0.8
Sandy loam, loam
16 - 30
0.6
Loam, porous silt loam
31 - 60
0.45
Silty clay loam, clay loam (d)
61 - 120
0.2 (e)
a. May be suitable estimates for sidewall infiltration rates.
b. Rates based on septic tank effluent from a domestic waste source.
A factor of safety may be desirable for wastes of significantly
different character.
Soils with percolation rates <1 min/in can be used if the soil is
replaced with a suitably thick (>2 ft) layer of loamy sand or
soil.
d Soils without expandable clays.
e. These soils may be easily damaged during construction.
EPA Design Manual: Onsite Wastewater Treatments and Disposal
Systems.
ISDS PERMIT: 1344 _ (p
DATE: Z cI G
rL�j�no..lertiv�o►v���C S ev,ce
ISDS FINAL1Coo5T, o850ZvATI&J
COMPLETENESS FORM
Tank is l SOgk gal. Tank Material: ` ire - Ut 1A <o
✓ Tank is located ft. and k5 0c' N -degrees from SY�%nda�ne�r-
(permanent landmark)
�,;ttsttnrn►m
REG/
Tank is located Z� ft. and 1 %�6$ t*3 degrees from (``eCwM otti-_"
•� �ppO
D PA,(permanent
landmark)
YtaVG
VP NO
/,1`
Tank set level. Y :SGYS Tank lids within 8" of finished grade.
A
i "ra'
Amps e�'
V : Size of field b ft 2— units lineal ft.
Technology
'O NAL
V/ Cleanout is installed in between tank and house (+ 1/100 ft)
ltt►ttntttttti
JThere is a "T" that goes down 14 inches in the inlet and outlet of the tank. �e
r>t-w1���
/ �
�rS�-w��Y
V Inlet and outlet is sealed with tar tape, rubber gasket, etc.
Tank has two compartments with the larger compartment closest to the house.
y Measure distance and relative direction to field. V% c N 4N �r-i
J Depth of field ft.
Y Soil interface raked. f+
`
Inspection portals at the end of each trench.
distance to setbacks.
y�Proper
/ Chambers properly installed per manufacturers specifications. (Chambers latched, end
plates properly installed,
rocks removed from trenches, etc.)
/ Other:
Inspection meets requirements.
Copy form to installer's file if recommendations for improvement were suggested.
ACTION TAKEN:
Setbacks
Well
Potable Water
Lines
House
Property
Line
Lake
Stream
Dry Gulch
Tank
Drain
Field
100
25
20
10
50
25
10
10
11 Tank
50
10
5
10
50
10
*
10
Ul
cn23
Z
" !ia
a cn
Ul MC
m C')
r- >
:< m -0
r-I
Cho
ZO
%Z
En
Ln ;M:o T
ca
r3
A
CP
0
0-4
M
CO)
4
0
0
1576-96 Tax# 2107-014-01-016
JOB NAME Lot#39,Fil rig`-1&2 BRAVERMAN
0150 Casteel Ridge
JOB ',kO. D
LOCATION
BILL TO
DATE STARTED
nn
DATE COMPLETED
DATE BILLED
L r
14 /V.0� 0 f7 A A
17
f
JOB COST SUMMARY
TOTAL SELLING PRICE
TOTAL MATERIAL
61
TOTAL LABOR
INSURANCE
SALES TAX
Misc. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 278 �pp NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471
®B FOLDER
Printed in U.S.A.