HomeMy WebLinkAbout492 Meadow Rd - 210507404001 - 0437IS - 157596ISEAGLE j'NTY DEPARTMENT OF ENVIRONt, r 'AL HEALTH Box 8�1 I 6th & Broadway P%RM15 MUST BE POSTED ON LOCATION 8 0 PLEASE CALL FOR FINAL INSPECTION Eagle, Colorado 81631 BEFORE COVERING ANY PART OF ST LED YSTE PERMIT N� 4�� �ffiis Yes no constitute a building or use permit) Owner JAMES A. HENDERSON/MARTHA B. HENDERSON LOT 5 - Block 4 - LAKE CREEK 14EADOWS - Filing #1 System Location Licensed Contractor (J`m Pe =#-4n) - ewHor responsible for installatio of system * Conditional Construction approval is hereby granted for a xx Septic Tank or Aerated treatment unit. Absorption area (or dispersal area) computed as follows: Perc rate 1 inches in 20 minutes 750 1,000 gallon sq. ft. absorption area per bedroom 250 sq. ft. # of bedrooms 3 x 250 sq. ft. minimum requirement May we suggest Date June 10, 1980 Inspector MINIMUM REQUIREMENTS: 1,000 gallon septic tank 750 sq. ft. leach field Erik W. Edeen FINAL APPROVAL OF SYSTEM: No system shall b 'deemed to be in compliance with the Sewage Disposal Laws until the assembled system is approved pri to covering any part. Se is Tank cleanout to within 12" of final grade or aerated access ports above grade. P per materials and assembly. Installed: 1,000 gallon septic tank JXA equ to absorption (or dispersal) area. 800 sq, ft. leach field equate compliance with permit requirements. Adequate compliance with County and State regulations/requirements. Date Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE *CONDITIONS: 1. All .installation must comply with all requirements of the County Individual Sewage Disposal Regulations, adopted pursuant to authority granted in 25-10-104, CRS 1973 amended 25-1-614, CRS 1973 2. This permit is valid only for connection to structures which have fully complied with County Zoning and building requirements. Connection to or use with any dwelling or structures not approved by the building and Zoning office shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Section III, 3.200requires any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications con- tained in the application of permit commits a Class I, Petty Offense ($500.00 fine - 6 months in jail or hnth " 328-7.311 PLEASE RETURN THIS PORTION WITH YOUR SITE PLAN AND FEES 949-5257 927-3823 _ENVIRONMENTAL HEALTH BOX 850 EAGLE, COLORADO 81631 PERMIT FEE = $75 PERCOLATION TEST FEE = $50 APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT NO. �%�& NAME OF OWNER: �- � / 9� JO/1� ,� 11,EA1JJ o1v %S�� ` 9�/ �J�� ADDRESS: .592p e—n 1�9,4-ff5oc-lezz ! Ew � 00 90-?,R7 PHONE: -6-Zc� e h � T NAME OF APPLICANT (IF DIFFERENT FROM OWNER): ADDRESS: PHONE: DESIGN ENGINEER OF SYSTEM (IF APPLICABLE): ADDRESS: PHONE: (/`PERSON RESPONSIBLE FOR INSTALLATION OF SYSTEM:,%» /.���"•�e�- �o,� `O��`� % ;3Dlt.r✓�� ADDRESS: PO 1.3,ax g r / ZJ.,r;1 e�Ie, ?/ e Y PHONE: 417L � f3�% PERMIT APPLICATION IS FOR: (� New Installation ( ) Alteration ( ) -epair _-tt� 3 z 2. LOCATION OF PROPOSED FACILITY: County L Lot Size City or Town, if within City or Town Limits LEGAL DESCRIPTION: 1--67- '5- ��,Oele z-Ao��E (,�c,,rE�e 4,E400V S STREET (RURAL) ADDRESS: V IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY? (1;o-) Yes ( ) No BUILDING OR.• -SERVICE TYPE: (Check applicable category) ( Residential - Single-family dwelling ( ) Residential - Triplex ( ) Residential- Duplex ( ) Residential - Quadplex ( ) Commercial - State usage # Persons o2 # Bedrooms WASTE TYPES: (Check all applicable) ( ) Commercial or Institutional Dwelling Garbage Grinder ( ) Non -domestic wastes ( ) Transient Use ( L) Dishwasher ( ) Other (- Automatic Masher SOURCE AND TYPE OF WATER SUPPLY: ( ) Well ( ) Spring ( ) Creek or Stream Give depth of all wells within 200 feet of the system: If supplied by community water, give name of supplier:l$A�F_ �p-t- E4 n7pS TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: ( t K Septic Tank ( ) Aeration Plant ( ) Chemical Toilet ( ) Vault Privy ( ) Composting Toilet ( ) Recycling, Potable Use ( ) Pit Privy ( ) Incineration Toilet ( ) Recycling, Other Use ( ) Greywater ( ) Other WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? ( ) Yes (-L,)" No Signature Date __L— 3 O _. gU INFORMATION BELOW TO BE FILLED OUT BY ENVIRONMENTAL HEALTH OFFICER %C00 GROUND CONDITIONS:, Percent Ground Slope: Z — '/" `77 ell Depth to Bedrock (per 8' Profile Hole): l Depth to Groundwater Table:? 7 SOIL PERCOLATION TEST RESULTS: Minutes per inch in Hole No. 1 l Minutes per inch in Hole No. 2 Minutes per inch in Hole No. 3 FINAL DISPOSAL BY: ( Absorpt ion Trench, Bed or Pit ( ) Evapotranspiration ( ) Above Ground Dispersal ( ) Sand Filter ( ) Underground Dispersal ( ) 'Wastewater Pond ( ) Other EAGLE COUNTY ENVIRONMENTAL HEALTH DATE REFERRED 0 _ ROUTE FORM / Al2 NAME LOCATION APPLICATION NO. Please review the attached application and return it and this completed form to the Environmental Health Office.. PL 'SING- Complies with: l Yes No Reviewed By Subdivision Regulations' Zoing Regulations I Recommend Approval Comments: BUILDING Set Backs f/ Site Other Comments MARAMOMMAWARM Comments commend Approval (not n Roads Grading Drainage Recommend EAGLE COUNTY BUILDING PERMIT APPLI UA ► I UN FINAL: C/O INSPECTION, LANDSCAPE INSPECTION FORM Review Routing Form ( ) Primary Routing (Rerouting Date Referred pl icant Permit No. Location Planning Commission File No. Review and return to the County Building Official within 6 working days Planning: Complies with: Yes No Subdivision Regulations ❑ H Zoning Regulations ❑ Site Plan (Landscaping) ❑ ❑ ❑ ❑ Comments: County Engineer: Roads ❑ ❑ Grading ❑ ❑ Drainage ❑ ❑ Comments: County Health: Water ❑ Sanitation ❑ ❑ ❑ I Perc. test ❑ I ❑ Comments: Reviewed by: Recommend Approval: Recommend Approval: ecommend Approval: Date: Final Inspection: C/O _ Recommend Approval ❑ ❑ Comments: Final Inspection: Landscaping Recommend Approval ❑ ❑ Comments: C/O I ssued by -D ate Final Filing Date EAGLE COUNTY BUILDING PE MIT APPLICATION FINAL: C/O INSPECTION, ANDSCAPE INSPECTION FORM Review Routing Form Primary Routing ( ) Rerouting 2L Date Referred Applicant Location xo Permit No. Planning Commission File No. Review and return to the County Building Official within 6 working days Planning: Complies with: Yes No Reviewed by: Subdivision Regulations ❑ Zoning Regulations - ❑ ❑ Site Plan (Landscaping) ❑ ❑ ❑ Recommend Approval: Comments: Date:"0 County Engineer: Roads ❑ ❑ Grading ❑ ❑ Drainage ❑ ❑ ❑ ❑ Recommend Approval: Comments: '��t$ �VV 2 `f County Health: Water ❑ 5-21-80 ncmoraan Sanitation Perc. test ❑ ❑ K Recommend Approval: Comments: Water is provided by Lake Crk Meadows Water District..approved water supply (2) The ISDS permit has not yet been issued because the percolation tests have not been conducted. The completed application has been returned. (3) Perc tests have not been conducted. Final Inspection: C/O Recommend Approval ❑ ❑ Comments: Final Inspection: Landscaping Recommend Approval ❑ ❑ Comments: C/O I ssued by Date Final Filing Date TOLL EA& E COUNTY Vai1REE949-5257 Basalt - 927-3823 DEPARTMENT 'OF BUILDING & PLANNING 21 May 1980 EAGLE, COLORADO 81631 TELEPHONE 303/328-7311 BOARD OF COUNTY COMMISSIONERS Ext241 James A. and Martha B. Henderson 5380 Mansfield ADMINISTRATION Ext241 Denver, Colorado 80237 ANIMAL SHELTER 949-4292 ASSESSOR RE: Application for Building Permit in Eagle County Ext202 Lot 5, Block 4, Lake Creek Meadows - Denied. BUILDING IN INSPECTION The Eagle County Building Dept. requires that applications for Building Ext 226or229 permits in Eagle County be routed to the Eagle County Planning, Engineering, CLERK & and Environmental Health Departments for.their comments prior to issuance RECORExt 217 of the permits. Your application was routed on 5/12/80. COUNTY ATTORNEY Listed below are the comments and recommendations which were made by the Ext242 above departments during the routing procedure. If you have any questions or wish to get further explanation, please contact the appropriate dept. ENGINEER Ext 236 Environmental Health - Not Approved. ENVIRONMENTAL 1) Water is provided by Lake Creek Meadows HEALTH Ext238 Water District —approved water supply. 2) The ISDS permit has not yet been issued EXTENSION AGENT because the percolation tests have not Ext247 been conducted. The completed application _ has been returned. LIBRARY Ext255 3) Perc tests have not been conducted. PUBLIC HEALTH Eagle Ext 252 Vail476-5844 PLANNING EM k Edeen �c/ Ext 226 or 229 Environmental Health O�ffi cer / PURCHASING/ PERSONNEL Ext 245 ROAD & BRIDGE Ext 257 SHERIFF Eagle Ext 211 Basalt 927-3244 Gilman 827-5751 SOCIAL SERVICES It would be to your advantage if you begin to resolve any problems and/or 328-6328 requirements as soon as possible so as not to delay the issuance of your TREASURER building permit any longer than necessary. Ext 201 `fies uoug Eagle County Building Official % PERCOLATION TEST FEE: $50 APPLICATION NO. OWNER: /��/%%�✓/li% / 1�� ��J� ti/C���'� �i LEGAL DESCRIPTION: 1,121 RURAL ADDRESS: TYPE OF DWELLING: Py/��y/ - , w lC� ffL'� �� OF BEDROOMS: DATE OF TEST: 8 TYPE OF SOIL: TEST HOLES PRESOAKED: YES NO TIME WATER DEPTH INCHES OF FALL RATE 1 2 3 1 2 3 1 2 3 1 2 3 I 72� l VIC _ l 20 vvrL ivrh ob"Gl -e- 'vvwYr Cf.- C =,_..a / 14-6-c-Ict PERCOLATION RATE: 20 -7, TANK SIZE: 00 Q SQUARE FOOTAGE PER BEDROOM: LEACH FIELD SIZE: Site has been reviewed and tested for/percolation rate. We recommend: APPROVAL DISAPPROVAL DATE: � �jlJ ��! EAGLE COUNTY ENVIRONMENTAL HEALTH OFFICER 0 EAGLE COUNTY 551 Broadway Eagle, Colorado 81631 (303) 328 7311 May 20, 1985 Buck Elliott R.O. Box 3142 Vail, CO 81658 RE: Lot 5, Blk 4, Lake Creek Meadows - Septic System An on -site inspection of the above referenced property revealed that the system is in proper working order and that the system will be sufficient to handle an additional bedroom. If there are any additional questions or concerns, please call this office. Sincerely, Erik.W. Edeen Environmental Health Officer EAGLE COUNTY EE/gp Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer P.O. Box 850 P.O. Box 449 P.O. Box 537 P.O. Box 359 P.O. Box 479 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 \ bh 164 Qb � -- I / O, I%f'C7%f%�Qe �pa'B Q� ' �„a•�/ `b` � ," (.'� „� r , ' , ;I t y 17, Al A, b WI f / // . � � ,i"� • / C i i1 "I 1 I 1 I , I I J '.� 1 � 1 �^.. f�'� . -\ ICI `I v` \ ` \ \ - .__. - 7.� / � _ ' / //l �/ r iii Vv ��+ . 111. 1 � � \ '\\ 1s � S\ •'\ �t y,`�,,\�i�t\ \�,~\ f .. _. r` i /%'i: _ I /• I 11 I ,�� , 1 ! ' , t �,\fit '� I , I -.�.. v �1 �.. - .• - INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 Telephone: 328-8755 o P YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1575 Please call for final inspection before covering any portion of installed system. Original permit # 437 , alteration OWNER:_Louise G. Elliott (Harris Trust) PHONE: 926-2112 MAILING ADDRESS:_ P.O. Box W Ciry: Edwards State: CO Z1p:81632 APPLICANT: Buck Elliott PHONE: 926-2112 SYSTEMLOCATION: 492 Meadow Rd. , Edwards CO TAX PARCEL NUMBER: 2105-074-01-013 LICENSED INSTALLER: Edwards Excavating, Dori JohnSon. LICENSENO: 11-96 DESIGN ENGINEER OF SYSTEM: Alpine Engineering Linn Schorr INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 1000 GALLON SEPTIC TANK ABSORPTION AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED N/A SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: Install new tank next to the existing tank to service addit'lon to the residenc Tnnkg will nor bp enn-nert-t-ti, hijt- will t-ii- in wit-b n joint connection n n 1 - beyond the tank outlets to sha e same 1 h L4elZd. ENVIRONMENTAL HEALTH APPROVAL: sy DATE: April 25, 1996 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL(�RUU-NTYE INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25- 10- 104. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DIS�PERSA'L rAREA:bo SQUARE FEET. rrTFSR - -ex�11,1 b/cJxu -kfEA�OOS6t INSTALLED SEPTIC PAON DEGREES! "M R` � SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY X YES _ NO COMPLIANCE WITH COUNTY / STATE REQUIREMENTS: X YES _ NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. l COMMENTS: SPe- 41P o/ L. T 1, e f U- rn Y" ENVIRONMENTAL HEALTH APPROVAL: DATE: ENVIRONMENTAL HEALTH APPROVAL: DATE: (RE-INSPECTI Y) RETAIN WITH RECEIPT RECORDS APPLICANT / AGENT: OWNER: PERMIT FEE PERCOLATION TEST FEE RECEIPT # CHECK # (Site Plan MUST be attached) ISDS Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * * * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: MAILING ADDRESS: APPLICANT/CONTACT MAILING ADDRESS: LICENSED ISDS COMPANY/DBA: ADDRESS: j-- 1U�-,71/2, *************************************************************************** PERMIT APPLICATION IS FOR: ( ) New Installation Alteration ( ) Repair LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Building Permit # (if known) Legal Description: Subdivision: /��� Filing:_B1ock:,�'Lot No. Tax Parcel Number: -1-�-� Lot Size: _ Street Address: 4W2 BUILDING TYPE: (Check applicable category) Residential/Single Family ( ) Residential/Multi-Family* ( ) Commercial/Industrial* TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Su face (jam Public Name of Supplier: Zsqxg *These systems rir Number Number Type _ of Bedrooms of Bedrooms y a Registered Professional Engineer R SIGNATURE: Date: ************ ** ********************************************************** TO BE COMPLETED BY TJE COUNTY j_ AMOUNT PAID: (, �C: RECEIPT #: l�'���(P DATE: CHECK #: CASHIER: =ZS Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO December 12, 1996 Louise G. Elliott P.O. Box W Edwards, CO 81632 try-�o i RE: Final of ISDS Permit No. 1575-96, Tax Parcel #2105-074-01-013. Property location: 492 Meadow Rd., Edwards, CO. Dear Mrs. Elliott: Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENMInformational brochure Final ISDS Permit cc: files ISDS PERMIT: DATE: 1 O —+ ISDS FINAL OBSERVATION COMPLETENESS FORM Tank is %gal. Tank Material: T Yc C y,CYeAc— Tank is located 50 r ft. and Vi 32� a degrees from (�Aea v- �t+•l / (permanent landmark) Tank is located N3 V , �� ft. and 16 degrees from OUST Cov �nC�'t' (permanent landmark) V Tank set level. V Tank lids within 8" of finished grade. N Fc Size of field ft2 units lineal ft. E X;S Technology V/Cleanout is installed in between tank and house (+ 1/100 ft) ` °/ There is a "T" that goes down 14 inches in the inlet and outlet of the tank. d � 9 (A S e. Inlet and outlet is sealed with tar tape, rubber gasket, etc. ou Tank has two compartments with the larger compartment closest to the house. f. r / V Measure distance and relative direction to field. Depth of field ft. N% Soil interface raked. - Or 1 `' Inspection portals at the end of each trench. y Proper distance to setbacks. A-b 0.30Sorrkib to ONI o.v-E0. Chambers properly installed per manufacturers specifications. (Chambers latched, end plates properly installed, rocks removed from trenches, etc.) Other: Inspection meets requirements. Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: Setbacks Well Potable Water Lines House Property Line Lake Stream Dry Gulch Tank Drain Field 100 25 20 10 50 25 10 10 Tank 50 10 5 10 50 10` * 10 HOLLY & BUCK ELLIOTT SEPTIC SYSTEM SUMMARY FOR 0492 MEADOW ROAD, LAKE CREEK MEADOWS SUBDIVISION LOT 5, BLOCK 4, EAGLE COUNTY This summary is presented to the Eagle County Environmental Health Division, following a meeting with Ray Merry on April 15, 1996. We discussed the septic system at 492 Meadow Road as per their addition / remodel and the need to upgrade the septic tank to the required amount of 1250 gallons,, it is presently a 1000 gal. tank and the elevation issue as regards the new addition. Plans for the new addition to the house, on the south end, calls for a drop of 14" below the existing slab on grade level. It has been concluded, following a field examination, that the location of the present tank, on the north end of the house does not allow for a sufficient elevation drop for the new addition, 2" short at 1 /8 inch per foot. In order to accommodate the need for the expanded tank capacity as well as meet the need for an elevation drop below the existing tank, it was proposed that a new 1000 gal. tank be placed next to the existing 1000 gal tank, bringing the total tank household capacity to 2000 gallons. Because of the elevation change in the new tank would be approximately 11 inches, given a preferred drop of 1/4 inch per foot, the two tanks would not be connected but would share the same leach field. A Y joint connection would occur 10'-15' beyond the tank outlets. The new tank would drain 2 toilets, 3 bathroom sinks, 2 showers, a bathtub, a laundry room sink, washer, and floor drain. The existing tank would drain/2 toilets, 3 bathroom sinks, a bathtub, 2 kitchen sinks and a dishwasher. In considering all the options available, the above proposal seems to be the most effective course of action and is presented to the Eagle County Environmental Health Division for approval. Submitted on April 24, 1996. P.O. Box W ■ 498 MEADOW ROAD ■ EDWARDS, COLORADO 81632 OFFICE: 303-926-2000 ■ HoME: 303-926-2112 ALPINE ENGINEERING, INC. April 24, -1996 Mr. Ray 1Vlerry Eagle County Department of Health and Environment P.O. Box 179 Eagle, CO 81631 RE: Elliott Residence ISDS Upgrade Dear Ray: I have reviewed remodelling plans. for Buck and Holly Elliott's house which -they plan to remodel,, adding one, bedroom. The additional bedroom requires, that the storage capacity;of the septic tank be increased to 1,125 gallons. The existing -ISDS system on site consists of a 1,000 gallon tank and leach field. The existing tank is located too high to allow "for gravity feed from the addition, and they -are proposing adding a second 1,000 gallon capacity tank next to the existing tank at a lower elevation to accommodate a portion of the effluent from the house. I have analyzedthe.water usage of fixtures feeding each of the tanks and found that the flow is split approximately evenly (4753) between the two tanks; the tanks appear to. be properly sized for peak flows. Please refer to the attached calculations. It is my understanding that the existing leach field has an absorption area of 800 square feet. You indicated to me that the soils on the site are sandy and should have a long-term' acceptance rate of 1:2 gallons per square foot; the proposed system will load at a "rate of 1.4 gallons per, square foot and should be adequate. I would recommend, for the ,purposes' of future flexibility, ;that the proposed tank be located near the existing tank with a separation of at least 3 feet.. Pipes carrying effluent from the two tanks should join in a wye 10'- 15 feet below the tanks. .`If you, have any questions concerning this amendment, please. do not hesitate to call me. Sincerely; Linn Schorr Environmental Engineer Enclosure cc: Buck and Holly Elliott Edwards Business Center •'P0. Box 97 - Edwards; Colorado 81632 (970) 926-3373 • Fax (970) 926-3390 Community Development Department (970)328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO Date: April 25, 1996 TO: Edwards Excavating FROM: Environmental Health Division Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Issuance of Individual Sewage Disposal System Permit No. 1575-96. Property Location: 492 Meadow Rd., Edwards, CO., Elliott residence. Enclosed is your ISDS Permit No. 1575-96. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files Alpine Engineering, Ind., Linn Schorr RPE ALPINE ENGIN: PROJECT S-::: \� -1 04 ki ERING, INC. rlm Im me IC(I'X DATE ��Dq lq� PAGE OF l PAGES ro. VU o 1575-96 Tax# 2105-07401 %*� JOB NAME 492 Meadow Rd. ELLIOTT g -- Lake Creek JOB NO• -' �� `� JOB LOCATION Al IA aYillj e� _ `�_ BILL TO DATE START D /t -- a DATE COMPLETED DATE BILLED 61-0114 d t 7K. %l. W O_ U G� r 1,4 n l W 411dfi < c it 4'�r'4'4 G F P! u' `�' ' '!/t �i�u .� abl�.�• + aj &-wI&C, ro7-"f'&lK le-u Ap i J4( ffik Vj\ IA4-% a A� S,,,,L, C122%Q,k � 2Z a, - 4A EL'iL J 64,11 4y, 1 J� ` `� ii\i V\ ]� //I�)/� I v 101 JOB COST SUMMARY TOTAL SELLING PRICE // ,h %S � ,itweur i�Lu•SS� fit, j �^-�� a �a�,-t.�J � TOTAL MATERIAL S-00 j k✓l` 7 (�6 otdx,)o Io TOTAL LABOR k^to, -filadOk% /� � /� /mot!/ AL s� GUI/ �R i��ieIdI INSURANCE (rt/b/�/ .S ' 1L SALES TAX S t� '(� S 4t k Od �r� N �A- . MISC. COSTS oll n cOXT5-7-0220 TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 �® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB FOLDER J, ,. �f Printed in U.S.A.