HomeMy WebLinkAbout32223 Hwy 6 - 194331100001 - 1507-95ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631
Telephone:328-8755
YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE.
Please call for final inspection before covering any portion of installed system.
6v( I( ld
PERMIT NO. 1507
OWNER: Cordillera Valley Club Investors Limited Partnership (970) 926-5339
PHONE:
MAILINGADDRESS: P.O. BOX 988 City: Edwards, State: CO Zip: 81632
APPLICANT: Linn Schorr PHONE: (970) 926-3373
SYSTEMLOCATION: 32223 Hlway 6, Edwards, CO TAX PARCEL NUMBER: 1943-311-00-001
LICENSED INSTALLER: Scott Green Excavating LICENSENO: 40-95
DESIGN ENGINEER OF SYSTEM: Alpine Engineering
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
1000 GALLON SEPTIC TANK
ABSORPTION AREA REQUIREMENTS:
SQUARE FEET OF SEEPAGE BED SQUARE FEET OF TRENCH BOTTOM.
SPECIAL REQUIREMENTS: Install as per engineer's design.
Ell k
ENVIRONMENTAL HEALTH APPROVAL: DATE:
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT
TO AUTHORITY GRANTED IN 25- 10- 104. 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION
TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A
REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED.
FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS
UNTIL THE SYSTEM IS APPROVED
PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET.
INSTALLED SEPTIC TANK: 1 (1(L n GALLON DEGREES 57 FEET FROM _t b e c o i th West r n rn e r Of t h a Sales o f f
SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND
PROPER MATERIAL AND ASSEMBLY X YES NO
COMPLIANCE WITH COUNTY/STATE REQUIREMENTS: X YES NO
ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED.
COMMENTS: Eng i naar rarti fi rati nn rorPi-ged 1 1 14 96
ENVIRONMENTAL HEALTH APPROVAL: DATE:_NnvpmhPr 1 f(, 1 99h
ENVIRONMENTAL HEALTH APPROVAL: DATE:
(RE -INSPECTION IF NECESSARY)
RETAIN WITH RECEIPT RECORDS
APPLICANT / AGENT:
PERMIT
PERCOLATION TEST FEE
OWNER:
RECEIPT #
CHECK#
Mr. Ray Merry
July 25, 1995
Page 2
ISDS Permit # /,5-0— �,l
Building Permit #
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
VIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
t P.O. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (Basalt)
PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
PROPERTY OWNER Gr f2jb1(,cF,¢,f ✓/lLLEY GLL) J✓ES7712S u.vi,,: ED Oi��2T.✓Ei�S6i/i°
MAILING ADDRESS: PHONE: 9Z� - 5339
APPLICANT/CONTACT PERSON: Linn Schorr. Alpine E 1Dineerin- Inc PHONE: (970) 926-3373
LICENSED SYSTEMS CONTRACTOR: .SCo i- Cgr h
ADDRESS: PHONE:__ �/} . 3p
***************************************
************
PERMIT APPLICATION IS FOR: (X) NEW CONSTRUCTION () ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description: NW 1/4 SW 1/4. SECTION 31, T4S R82W 6th P.M., Ea le Co. CO
Parcel Number:_ 001L0 i LL~- Jl�i •i �'' T cr,
Lot size: 511 _
Physical Address: 141,;i /~Iny- tii
r �1
BUILDING TYPE: (Check applicable category)
() Residential/Single Family Number of Bedrooms
() Residential/Multi-Family* Number of Bedrooms
(X) Commercial/Industrial* Type Real'Estate Sales Office
TYPE OF WATER SUPPLY: Well( Spring O Surface 00
Public () Name of Supplier:
*These systems require design by a Registered Professional Engineer
NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION
MAKE ALL REMITTANCE PAYABLE O: "EAGLE COUNTY TREASURER"
60w/ , i S irvv'(.`�7757r3' GiriivA f' 7—o��r ;d'
SIGNATURE.
DATE:
AMOUNT PAID: _/j a_ RECEIPT # O _ D
/ATE:
CHECK #— CASHIER•. U
Community Development Department
(970) 328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
November 18, 1996
Cordillera Valley Club Investors Limited Partnership
P.O. Box 988
Edwards, CO 81632
RE: Final of ISDS Permit No. 1507-95, Tax Parcel #1943-311-00-001.
Property location: 32223 Hwy 6, Edwards, CO.
Dear CVC Partners:
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance
with any other Eagle County requirements. Also enclosed is a brochure regarding the care of
your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Information Brochure
Final ISDS Permit
cc: files
COMMUNITY DEVELOPMENT
DEPARTMENT
(303) 328.8730
EAGLE COUNTY, COLORADO
Date: July 28, 1995
TO: Scott Green Excavating
FROM: Environmental Health Division
725 CHAMBERS AVE.
P.O. BOX 179
EAGLE, COLORADO 8101
FAX (303) 328.7207
RE: Issuance of Individual Sewage Disposal System
Permit No. 1507-95 Tax Parcel #1943-311-00-001
Property Location: 32223 Highway 6, Edwards, Co.
Cordillera Real Estate Sales Office.
Enclosed is your ISDS Permit No. 1145-92 is valid for 120 days.
The enclosed copy of the permit must be posted at the
installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved. Please call
our office well in advance for the final inspection.
Systems designed by a Registered Professional Engineer must be
certified by the Engineer indicating that the system was
installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Engineer as builts must
be submitted for permit to'be finalized and C.O. issued.
Permit specifications are minimum requirements only, and should
be brought to the property owner's attention.
This permit does not indicate conformance with other Eagle County
requirements.
If you have any questions, please feel free to contact the
Environmental Health Division at 328-8755.
cc: files
Community Development Department
(970) 328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
December 12, 1995
Dear Applicant,
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
The Environmental Health Division would like to notify you to
make a formal request to extend your Individual Sewage Disposal
System(ISDS) Permit #ryO? q5 into the 1996 construction year. The
Environmental Health Division discontinued percolation tests on
November 15, 1995 and final inspections on December 2, 1995 due
to climatic conditions.
ISDS permits are active for 120 days after the date of issue if
no Building Permit has been issued for the same property. If a
Building Permit has been issued for the same property the ISDS
will expire at the same time as the building permit.
If you still plan to apply for a Building Permit this year or in
the early months of 1996 you will need to have a percolation test
conducted before your.Building Permit will be released. You will
have to contact a Registered Professional Engineering(RPE) firm
to conduct your percolation test.
If you have had your permit issued and have not had your final
inspection completed, but plan on constructing the system in the
next few weeks, please give our office a call and we will
evaluate your permit on a case by case situation.
Please give the Environmental Health office a call at 328-8755,
if you have any questions regarding your permit extension
process.
cc: ISDS Permit File
ALPINE ENGINEERING, INC.
July 25, 1995
4 ' officeworkers x 15 gpd x 1:5' peaking factor 90 gpd
Edwards Business Center • P.O. Box 97 • Edwards, -Colorado 81632 •' (970) 926-3373 • Fax (970) 926-3390'
f
ALPINE
_ - --- = Edwards Business Center\P.O. Box 97
— — = Edwards, CO 91632
ENGINEERING INC PH: (970) 926-337.3 FAX: (970) 926-3390
FACSIMILE TRANSMISSION: jute; it
Time:
Job:
To,_.
To;
CO: 6-4416IC GO, /�✓/iforJ,�l�i+1J C. ,Wf4?41to:
Fax #: 3 e 2/ IS _._ Fax 9;
To:
Co:
Fax #:
To -
Co:
Fax #:
To;
Co.
Fax #:
To:
Co:
Fax #:
From-
(If there are any problems concerning this FAX please call Marian at 926-3373)
Number of Pages (including cover sheet): Z
Transmitted:
for approval
for review and comment
Remarks: C Vc-
as requested
for :Yo
ur record
reviewed
other
for your use
AA
Confidentiality Statement: This facsimile transmission and any accompanying documents contain information
belonging to the sender which may be confidential and legally privileged. This information is intended only for
the use of the individual or entity to whom this facsimile transmission was sent as indicated above. If you are
not the intended recipient, any disclosure, copying, distribution or action taken in reliance on the contents of the
information contained in the facsimile is strictly prohibited. If you have received this transmission in error,
please call us collect to arrange for the return of the documents to us at our expense- Thank you,
1SDS PERMIT: 1 ?�K] r — t DATE; 1\ \4 R(,
ISI1S FINAL OBSERVATION COMPLETENESS FORM
Tank is 1 IQCO Eat. Tank Material '[e`vtRwyie�,€
V/_ Tank is located 5-4 -oft. and __ degrees from b v-eve r o iL
,! (permament landmark)
�! Tank is located `e D- Lift. and degrees from N W a, ' its t4—
Y nc,lr a
(permanent landmark)
Tank set level_ V Tank lids within 8" of finished grade.
N A, Size of field fix
Technology
units_ _•^lineal ft.
t/ Cleanout is installed in between tank and house (+ 1/100 ft)
NON There is a "T" that goes do%%m 14 inches in the inlet and outlet of the tank.
�, t Inlet and outlet is sealed with tar tape, rubber gasket, etc.
Tank has two compartments with the larger compartment closest to the house.
1�+ _Measure distance and rciativc direction to field.
t� A Depth of field ft,
Soil inlcrface raked.
1� N..-Inspection portals at the end of each trench.
Proper distance to setbacks,
Q r�,L10 Rif CIS+�F
.022753 1
dd
_Chambers properly installed per manufacturers specifications. (Chambers laichcd, end plates properly installed,
rocks removed from trenches, etc.)
Othcr:
v Inspection meets reouirements.
Copy form to installer's file if recommendations for improvement were suggested. � �}
�h 4 A:\PSo'f ii o %& aLyXM, J
Setbacks
well
Potable Water
Lines
House
Property
Line
Lake
Stream
Dry Gulch
Tank
Drain
Field
IO0
25
20
10
so
25
10
10
Tank
50
10
5 1
10
s0
T 10
a
]0
LIWN 5ckvrale :a = J
1507-95 Tax# 1943-311-00-001
JOB NAME _ 32223 Hiway 6 CCVILP JOB NO.
Cordillera Sales Office
r777770N
BILL TO
DATE. STARTED DATE. COMPLETED DATE BILLED
A,
JOB COST SUMMARY
TOTAL SELLING PRICE
'TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 278NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB.FOLDER Printed in USA
j