HomeMy WebLinkAbout21234_Haymeadow_BLDG G_PERMIT RESUBMITTAL_PLBG_2023-03-03DOMESTIC COLD WATER PIPING
DOMESTIC HOT WATER PIPING
DOMESTIC HOT WATER RECIRCULATION PIPING
140°F DOMESTIC HOT WATER PIPING
140°F DOMESTIC HOT WATER RECIRC. PIPING
SANITARY PIPING
VENT PIPING
STORM PIPING
OVERFLOW STORM PIPING
CONDENSATE DRAIN PIPING
NATURAL GAS PIPING
LIQUID PETROLEUM GAS PIPING
GREASE WASTE PIPING
ACID WASTE PIPING
ACID VENT PIPING
COMPRESSED AIR PIPING
FIRE PROTECTION PIPING
FIRE SPRINKLER PIPING
SAN
V
ST
OST
CD
G
LPG
GW
AW
AV
CA
F
FS
140°
140°
PIPING SYSTEMS
PLUMBING SYMBOLS
AAV AIR ADMITTANCE VALVE
AD AREA DRAIN
AFF ABOVE FINISHED FLOOR
AV ACID VENT
AW ACID WASTE
BF BOTTLE FILLER
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BP BOOSTER PUMP
BT BATH TUB
BTU BRITISH THERMAL UNIT
CB CATCH BASIN
CD CONDENSATE DRAIN
CO CLEANOUT
CP CIRCULATION PUMP
CW COLD WATER
DEG,° DEGREES
DDC DIRECT DIGITAL CONTROL
DF DRINKING FOUNTAIN
DN DOWN
DSN DOWNSPOUT NOZZLE
DT DILUTION TANK
(E) EXISTING TO REMAIN
EEW EMERGENCY EYE WASH
ES EMERGENCY SHOWER
ESP ELEVATOR SUMP PUMP
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FFE FINISHED FLOOR ELEVATION
FHC FIRE HOSE CABINET
FPM FEET PER MINUTE
FS FLOOR SINK
G NATURAL GAS
GCO GRADE CLEANOUT
GD GARBAGE DISPOSAL
GPM GALLONS PER MINUTE
GT GAS TURRET
GV GAS VALVE
GWH GAS WATER HEATER
HB HOSE BIBB
HD HEAD
HP HORSEPOWER
HW HOT WATER
HWC HOT WATER CIRCULATION
HX HEAT EXCHANGER
HZ HERTZ
IE INVERT ELEVATION
IMB ICE MAKER BOX
IN W.C.INCHES OF WATER COLUMN
KW KILOWATT
L LAVATORY
LBS POUNDS
LPG LIQUEFIED PETROLEUM GAS
LS LAUNDRY SINK
LWT LEAVING WATER TEMPERATURE
MBH 1000 BTU PER HOUR
MFR MANUFACTURER
MH MANHOLE
MSB MOP SINK BASIN
(N) NEW
N2 NITROGEN
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NO NORMALLY OPEN
O2 OXYGEN
OD OVERFLOW DRAIN
PH,ø PHASE
PIV POST INDICATOR VALVE
PRV PRESSURE REDUCING VALVE
PT PLASTER TRAP
QTY QUANTITY
(R) RELOCATED EXISTING
RC REFRIGERANT CHARGE
RD ROOF DRAIN
RPM REVOLUTIONS PER MINUTE
S SINK
SA SHOCK ARRESTOR
SAN SANITARY
SE SEWAGE EJECTOR
SP SUMP PUMP
ST STORM, STORAGE TANK
SV SHOWER VALVE
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TEA THERMAL EXPANSION ABSORBER
TG TRAP GUARD
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TSP TOTAL STATIC PRESSURE
TW TEPID WATER
U URINAL
U/F UNDERFLOOR
U/G UNDERGROUND
U/S UNDERSLAB
V VENT
VAC VACUUM
VTR VENT THROUGH ROOF
WB WASHER BOX
WC WATER COLUMN, WATER CLOSET
WCO WALL CLEANOUT
WH WALL HYDRANT
GENERAL PIPING
NEW LINEWORK
EXISTING LINEWORK
/DEMOLITION LINEWORK
1. THE PLANS ARE, TO A GREAT EXTENT, DIAGRAMMATIC IN NATURE.
DRAWING SCALES SHOULD BE VERIFIED FROM DIMENSIONS ON ARCH. PLANS.
THE INFORMATION PRESENTED IS AS EXACT AS COULD BE SECURED. THE
CONTRACTOR SHALL OBTAIN EXACT LOCATION, MEASUREMENTS LEVELS,
ETC. AT THE SITE AND SHALL SATISFACTORILY ADAPT THE WORK TO THE
ACTUAL CONDITIONS AT THE PROJECT SITE.
2. CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO SUBMITTING A BID TO
COVER THE CONDITIONS AT THE SITE INFORMING THEMSELVES OF ALL
DETAILS.
3. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND
LOCAL CODES, LAWS, ACTS AND ORDINANCES, AND ALL AUTHORITIES HAVING
JURISDICTION.
4. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL
ENGINEERING REQUIREMENTS, THE OWNER'S DESIGN CRITERIA, UTILITY
COMPANY REQUIREMENTS, APPLICABLE INDUSTRY STANDARDS OF GOOD
PRACTICE AND SAFETY, AND THE MANUFACTURER'S STRICTEST
RECOMMENDATIONS FOR EQUIPMENT AND PRODUCT APPLICATION AND
INSTALLATION.
5. RECORD DRAWINGS - PREPARE AND SUBMIT TO THE OWNER RECORD
DRAWINGS INDICATING THE EXACT LOCATION OF ALL EQUIPMENT INCLUDING
THE EQUIPMENT'S "AS INSTALLED" SIZE(S). MANUFACTURER, MODEL
NUMBERS, AND PERFORMANCE RATINGS.
6. SUPPORTS - EQUIPMENT, PIPING, OR ANY OTHER ACCESSORY SHALL NOT
BE SUPPORTED FROM OTHER PIPING, DUCTWORK, METAL ROOF DECK,
LATERAL BRACING BRIDGING, OR CONDUIT. ITEMS SHALL ONLY BE
SUPPORTED FROM BUILDING STRUCTURE.
7. COORDINATE EXACT LOCATION OF ALL PIPING AND EQUIPMENT WITH
STRUCTURAL, ARCHITECTURAL, ELECTRICAL, AND OTHER MECHANICAL
SYSTEMS.
8. WHERE MOUNTING HEIGHTS ARE NOT DETAILED OR DIMENSIONED, INSTALL
MECHANICAL SERVICES AND OVERHEAD EQUIPMENT TO PROVIDE THE
MAXIMUM HEADROOM POSSIBLE.
9. ALL PIPING TO VIBRATING EQUIPMENT SHALL HAVE FLEXIBLE
CONNECTORS.
10.COORDINATE ALL ROOF AND CHASE PENETRATIONS WITH STRUCTURAL
DRAWINGS AND ROOF INSTALLER.
11.OWNER TO HAVE CHOICE SALVAGE OF ALL PLUMBING FIXTURES AND
EQUIPMENT WHICH ARE PLANNED TO BE REMOVED BY CONTRACTOR.
EQUIPMENT NOT SALVAGED BY OWNER SHALL BE REMOVED FROM SITE AND
PROPERLY DISPOSED OF BY THE CONTRACTOR.
12.BEFORE REMOVAL OF ANY MECHANICAL EQUIPMENT, CONTRACTOR SHALL
RECOVER USED REFRIGERANT IN A PROPERLY LABELED D.O.T. APPROVED
REFILLABLE CYLINDER TO MEET E.P.A. STANDARDS. RECOVERED
REFRIGERANT MUST BE CHEMICALLY ANALYZED AND REPROCESSED OR
DISPOSED OF PER E.P.A. REQUIREMENTS, SECTION 608 OF THE CLEAN AIR
ACT AND A.R.I. STANDARD 700.
13.THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN
APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT
LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK.
14.ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT
OR PIPING INSULATION IS APPLIED.
15.CONCRETE HOUSEKEEPING PADS TO SUIT MECHANICAL EQUIPMENT SHALL
BE SIZED AND LOCATED BY THE MECHANICAL CONTRACTOR. MINIMUM
CONCRETE PAD THICKNESS SHALL BE 6 INCHES. PAD SHALL EXTEND BEYOND
THE EQUIPMENT A MINIMUM OF 6 INCHES ON EACH SIDE. CONCRETE
HOUSEKEEPING PADS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR.
IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO
COORDINATE THE SIZES AND LOCATIONS OF CONCRETE HOUSEKEEPING
PADS WITH THE GENERAL CONTRACTOR.
16.ACCESS PANELS ARE REQUIRED (MIN. 18"X18") FOR ACCESS TO EVERY
VALVE AND CONTROL SENSOR IF NOT OTHERWISE ACCESSIBLE. ACCESS
PANEL SHALL BE APPROVED BY ARCHITECT/ENGINEER. COORDINATE PANEL
LOCATIONS WITH THE ARCHITECT PRIOR TO INSTALLATION.
17.PROVIDE SHUTOFF VALVES IN ALL DOMESTIC WATER PIPING SYSTEM
BRANCHES IN WHICH BRANCH PIPING SERVES TWO OR MORE FIXTURES.
18.ROUTE ALL PIPING PARALLEL TO BUILDING WALLS, STRUCTURE AND
FEATURES, AS HIGH AS POSSIBLE, AND OFFSET AS NECESSARY TO AVOID
STRUCTURAL MEMBERS, MECHANICAL EQUIPMENT AND THE LIKE.
19.REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS OF
STANDARD AND ACCESSIBLE PLUMBING FIXTURES.
20.SLOPE ALL SANITARY WASTE PIPE SIZES 3" AND UNDER AT 1/4 INCH PER
FOOT.
21.SLOPE ALL SANITARY WASTE PIPE SIZES 4" AND ABOVE AT 1/8 INCH PER
FOOT.
22.SLOPE ALL STORM AND OVERFLOW STORM PIPING AT 1/8 INCH PER FOOT.
23.SLOPE ALL CONDENSATE DRAINAGE PIPING AT 1/8 INCH PER FOOT.
PIPE VALVES & SYMBOLS
DIRECTION OF FLOW IN PIPING
BALL VALVE
CHECK VALVE
BUTTERFLY VALVE
BALANCING VALVE
GATE VALVE
GLOBE VALVE
SOLENOID VALVE
THERMOSTATIC MIXING VALVE
STRAINER
STRAINER WITH BLOWOFF
RELIEF / SAFETY VALVE
PRESSURE REDUCING VALVE
VACUUM BREAKER
GAS COCK
HOSE END BALL VALVE
UNION
THERMOMETER
PIPING ELBOW UP
PIPING ELBOW DOWN
PIPING TEE UP
PIPING TEE DOWN
PIPE CAP
PIPING REDUCER
SHOCK ARRESTOR
LINE CLEANOUT / WALL CLEANOUT
AQUASTATA
S
HOSE BIBB / WALL HYDRANT
VENT THRU ROOF
FLOOR SINK (FULL, QUARTER & HALF GRATE), SIZE AND TYPE
FLOOR DRAIN, SIZE AND TYPE
ROOF DRAIN, SIZE AND TYPE
OVERFLOW DRAIN, SIZE AND TYPE
FLOOR / GRADE CLEANOUT, SIZE
3"FS-1
3"FD-1
3"RD-1
3"OD-1
3"FCO /
3"GCO
GARBAGE DISPOSAL UNIT
1
A-101
SIM
A-101
1 SIM
SECTION CUT: UPPER NUMBER INDICATES
DETAIL, LOWER NUMBER INDICATES SHEET
DETAIL REFERENCE: UPPER NUMBER INDICATES
DETAIL, LOWER NUMBER INDICATES SHEET
X
X
GENERAL SYMBOLS
KEY NOTE REFERENCE
CONNECTION POINT OF NEW TO EXISTING
RISER DIAGRAM REFERENCE
ELEVATION MARKName
Elevation
EXTENT OF DEMOLITION SYMBOL
GRAPHIC SCALE
DOUBLE CHECK VALVE
ABBREVIATIONS GENERAL NOTES studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P000
PLUMBING
LEGEND & NOTES
SD
MB
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
G
I. CODES
A. ALL EQUIPMENT AND THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH THE APPLICABLE
PROVISIONS OF THE LATEST EDITION OF THE INTERNATIONAL PLUMBING CODE, O.S.H.A. REQUIREMENTS,
LIFE SAFETY CODE AND ALL APPLICABLE LOCAL AND STATE LAWS AND ORDINANCES.
B. THE CONTRACTOR SHALL PAY ALL INSPECTION FEES AND PURCHASE ALL PERMITS REQUIRED FOR THIS
WORK.
II. LOCATION OF EQUIPMENT
A. THE CONTRACTOR SHALL NOTE THAT THE PLUMBING DRAW INGS ARE INTENDED TO INDICATE ONLY THE
EXTENT DIAGRAMMATICALLY, GENERAL CHARACTER AND LOCATION OF THE WORK. WORK INTENDED, BUT
HAVING MINOR DETAILS OBVIOUSLY OMITTED, SHALL BE FURNISHED AND INSTALLED COMPLETE BY THIS
CONTRACTOR AT HIS EXPENSE.
III. ROUGH-IN
A. VERIFY FINAL LOCATIONS FOR ROUGH-INS WITH SHOP DRAWINGS, FIELD MEASUREMENTS AND WITH THE
REQUIREMENTS OF THE ACTUAL EQUIPMENT TO BE CONNECTED PRIOR TO ROUGH-IN.
B. REFER TO EQUIPMENT SPECIFICATIONS IN DIVISIONS 1 THROUGH 15 FOR ROUGH-IN REQUIREMENTS.
C. OBTAIN FROM OWNER AND GENERAL CONTRACTOR COPIES OF "EQUIPMENT BROCHURE" AND A SET OF
SHOP DRAWINGS OF EQUIPMENT BEFORE ROUGHING IN ANY WATER, WASTE, CONNECTIONS, ETC.
CHANGES RESULTING FROM FAILURE TO OBTAIN THIS INFORMATION WILL NOT RESULT IN ADDITIONAL
COST.
IV. WARRANTIES
A. GUARANTEE ALL PLUMBING SYSTEM MATERIALS AND WORKMANSHIP TO BE FREE FROM DEFECTS FRO A
PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE AND PROPERLY CORRECT LATENT
DEFECTS ARISING WITHIN THIS PERIOD UPON NOTIFICATION BY THE OWNER'S REPRESENTATIVE WITHOUT
ADDITIONAL COMPENSATION.
V. CHANGES
A. THE DRAWINGS INDICATE GENERALLY THE LOCATIONS OF PLUMBING FIXTURES, APPARATUS, PIPING,
ETC., BUT IF, BEFORE INSTALLATION, IT IS FOUND NECESSARY TO CHANGE THE LOCATION OF SAME TO
ACCOMMODATE THE CONDITIONS AT THE BUILDING, SUCH CHANGES SHALL BE MADE WITHOUT
ADDITIONAL COST TO THE OWNER AND AS DIRECTED BY THE OWNER.
VI. PLUMBING SUBMITTALS
A. SUBMITTAL ARE REQUIRED ON THE FOLLOWING ITEMS AND THEY MUST BE SELECTED FROM ONE OF THE
MANUFACTURERS LISTED, OR OTHERWISE BE AN APPROVED ALTERNATE.
1. PLUMBING FIXTURES
2. FLOOR DRAINS AND SINKS
3. CLEANOUTS
4. PLUMBING FIXTURE SUPPORTS
B. LOW FLOW REQUIREMENTS
1. 1.28 GPF WATER CLOSETS
2. 0.25 GPF URINALS
3. 0.5 GPM LAVATORY FAUCETS
4. 1.5 GPM KITCHEN FAUCETS
VII. AS BUILT DRAWINGS
A. FURNISH THE OWNER TWO (2) HARD COPIES AND ONE (1) SOFT COPY OF AS-BUILT DRAWINGS AND O&M
MANUALS UPON COMPLETION OF THE WORK.
I. PIPING
A. SANITARY DRAIN LINES AND BRANCHES SHALL BE SOLID-WALL SCHEDULE 40 PVC WITH GLUED JOINTS,
CONFORMING TO ASTM D 2665, DWV. CAST-IRON PIPE AND FITTINGS CONFORMING TO ASTM A 888 OR CISPI
1301 FOR ABOVE GRADE SANITARY AND VENT PIPING SHALL BE PROVIDED AS A PRICING OPTION FOR THE
OWNER'S APPROVAL.
B. HOT AND COLD WATER PIPE ABOVE CEILING SHALL BE ASTM B88 TYPE "L" HARD DRAWN COPPER WITH
ASME B16.22 WROUGHT COPPER FITTINGS, 100% LEAD-FREE SOLDER JOINTS: APPLY ASTEM B 813 WATER
WASHABLE FLUX TO END OF TUBE, JOIN COPPER TUBE AND FITTINGS ACCORDING TO ASTM B 828 OR
CDA'S "COPPER TUBE HANDBOOK."
C. PEX TUBING (ASTM F 877, SDR 9) SHALL BE APPROVED FOR PIPE SIZES 2" AND SMALLER WITH OWNER'S
APPROVAL. FITTING FOR PEX TUBING SHALL BE ASTM F 1807 METAL-INSERT TYPE WITH COPPER OR
STAINLESS-STEEL CRIMP RINGS AND MATCHING PEX TUBE DIMENSIONS.
D. ALL WATER PIPING BELOW GRADE SHALL BE ASTM B88 TYPE "K" SOFT COPPER WITH NO JOINTS, OR PEX
PIPING WITH OWNER'S APPROVAL.
E. GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL.
F. BRASS, COPPER AND CHROME PLATED MANUFACTURERD PIPE NIPPLES SHALL BE CONFORM TO ASTM B
687. STEEL MANUFACTURED PIPE NIPPLES SHALL CONFORM TO ASTM A 733.
G. EXPOSED PIPE IN RESTROOMS SHALL BE CHROME PLATED BRASS WITH CHROME PLATED WALL PLATES.
AMERICAN BRASS CO. OR EQUIVALENT.
H. ALTERNATIVE PIPE MATERIALS, SUCH AS PROPRESS OR PEX MANIFOLDS FOR DOMESTIC WATER OR CSST
FOR NATURAL GAS, SHALL BE ALLOWED WITH ACCEPTANCE FROM OWNER AND ENGINEER ONLY.
MODIFICATIONS TO DESIGN AND LAYOUT OF PIPING SYSTEMS TO ACCOMODATE ALTERNATIVE MATERIALS
SHALL BE THE CONTRACTOR'S RESPONSIBILITY.
II. CLEANOUTS
A. WALL CLEANOUTS SHALL BE CAST IRON WITH BRASS PLUG AND POLISHED BRASS ACCESS COVER WITH
COUNTER SUNK BRASS SCREW. THEY SHALL BE OF STANDARD PIPE SIZES.
B. FLOOR CLEANOUTS SHALL HAVE CAST IRON BODY, NICKEL BRONZE SCORIATED TOP AND RUBBER
GASKETED CONNECTION, PROVIDE AS SCHEDULED OR APPROVED ALTERNATE.
III. VALVES
A. BALL VALVES SHALL BE 125 POUND, SCREWED, ALL BRONZE, TWO PIECE, FULL PORT DESIGN. NIBCO T-580
OR EQUIVALENT.
B. BALANCING VALVES SHALL BE LEAD FREE, CALIBRATED TYPE, SUITABLE FOR POTABLE WATER SYSTEMS,
MEETING NSF-61. BELL AND GOSSETT CIRCUIT SETTER OR EQUAL
IV. P-TRAPS
A. FLOOR DRAINS SHALL HAVE CAST IRON DEEP SEAL TRAPS WITH PROSET TRAP GUARDS, NOT TO BE
INTEGRAL WITH DRAINS.
B. SINKS AND LAVATORIES SHALL HAVE CHROME PLATED COPPER P-TRAPS, 17 GA. MINIMUM.
V. ESCUTCHEON PLATES
A. CHROME PLATED ESCUTCHEON PLATES FOR ALL EXPOSED PIPE PASSING THROUGH WALLS, FLOORS, OR
CEILINGS.
VI. FLOOR DRAINS AND FLOOR SINKS
A. FLOOR DRAINS SHALL BE PROVIDED AS SCHEDULED OR APPROVED ALTERNATE.
B. FLOOR RECEPTOR SHALL BE PROVIDED AS SCHEDULED OR APPROVED ALTERNATE.
VII. PIPE INSULATION
A. PROVIDE RIGID FIBERGLASS PIPE INSULATION WTIH INTEGRAL VAPOR BARRIER. INSULATE HOT AND COLD
WATER PIPING IN ACCORDANCE WITH 2015 IECC TABLE C403.11.3:
I. INSTALLATION OF PIPING
A. ALL BELOW GRADE PIPE INSTALLATION SHALL BE IN ACCORDANCE WITH IPC SECTION 306, TRENCHING,
EXCAVATION AND BACKFILL.
B. ON VERTICAL SANITARY DRAIN LINES, CONNECT ALL SOIL AND WASTE INLETS THROUGH SANITARY TEES,
WYES, OR WYES AND EIGHT BENDS. SHORT RADIUS FITTINGS MAY BE USED FOR VENT PIPING. ON
HORIZONTAL LINES, CONNECT ALL WASTE AND SOIL CONNECTIONS THROUGH WYES, OR WYES AND
EIGHTH BENDS. DOUBLE BRANCH FITTINGS MAY BE USED ON VERTICAL LINES AND HORIZONTAL RUNS
PROVIDING PROPER GRADES CAN BE MAINTAINED.
C. MAKE SCREW JOINTS BETWEEN CAST IRON PIPES AND OTHER PIPES WATER-TIGHT WITH APPROVED
COMPOUND. JOIN BELL & SPIGOT PIPING WITH THE USE OF AN APPROVED NEOPRENE RUBBER GASKET
CONFORMING TO ASTM C 564.
D. LAY HORIZONTAL DRAIN PIPES TO UNIFORM GRADE; RISER PIPES, VERTICAL. MAKE CHANGES IN
DIRECTIONS OF DRAIN PIPES WITH LONG BENDS. NO SCREWED JOINTS PERMITTED IN DRAIN PIPES,
EXCEPT AS DESCRIBED HEREIN BEFORE.
E. PITCH ALL HORIZONTAL DRAINS 1/8" PER FOOT MINIMUM, OR AS PER LOCAL CODE.
F. PROVIDE CLEANOUTS AT EVERY CHANGE IN DIRECTION OF MORE THAN FORTY-FIVE DEGREES AND
EVERY FIFTY FEET AS REQUIRED BY LOCAL CODES.
G. CUT BRASS AND COPPER PIPE BY MEANS OF A TUBING CUTTER. REMOVE ALL BURRS AND METAL CHIPS,
DIRT, ETC., BEFORE JOINING PIPE. CHROME PLATED PIPE SHALL SHOW NO WRENCH MARKS AFTER
INSTALLATION; NO THREADS SHALL SHOW.
H. ADEQUATELY SUPPORT ALL PIPING ABOVE FLOORS, INSIDE THE BUILDING FROM OR ON THE BUILDING
STRUCTURE. SUPPORT PIPING SUSPENDED FROM THE BUILDING STRUCTURE BY MEANS OF THE
SPECIFIED PIPE HANGERS AND RODS. MAKE MAXIMUM SPACING BETWEEN PIPE SUPPORTS AS FOLLOWS:
PIPE MATERIAL MAXIMUM HORIZONTAL SPAN
CAST-IRON 5'
COPPER PIPE 12'
COPPER TUBING SIZES
1-1/2" AND LARGER 10'
COPPER TUBING SIZES
1-1/4" AND SMALLER 6'
PEX PIPE 2.67' (32")
PVC PIPE 4'
H. SUPPORT VERTICAL PIPING AT BASE OF RISER AND AT EVERY 10'-0" OF RISE, EXCEPT PEX PIPE WHICH
SHALL BE SUPPORTED EVERY 4'-0" OF VERTICAL RISE.
I. ACOUSTIC WRAP PADS AND ISOLATERS SPECIFIED AT DWV AND DOMESTIC SUPPLY COMPONENTS
SHALL BE INSTALLED PER MANUFACTURER SPECIFICATIONS.
J. REFER TO ARCHITECTURAL PLANS FOR U.L. ASSEMBLIES AND REQUIRED METHODS FOR PLUMBING
MEMBRANE PENETRATIONS THROUGH FIRE RATED ASSEMBLIE
II. INSTALLATION OF VALVES
A. ISOLATE ALL MAJOR ASSEMBLIES AS SHOWN ON THE DRAWINGS AND AS REQUIRED FOR PROPER
OPERATION AND MAINTENANCE. ALL VALVES SHALL BE ACCESSIBLE. PROVIDE VALVE BOXES AND ACCESS
PANELS WHERE REQUIRED FOR ACCESSIBILITY.
B. PROVIDE DOMESTIC WATER AND GAS SHUT-OFF IN THE UTILITY AREA OF EACH INDIVIDUAL UNIT. SHUT-
OFF VALVES SHALL BE LOCKING TYPE, AND UPSTREAM OF SUBMETERS. LOCKS PROVIDED BY OWNER.
III. INSTALLATION OF TRAPS
A. TRAP EACH FIXTURE BY WATER SEALING TRAP PLACED AS NEAR THE FIXTURE AS POSSIBLE.
B. VENT ALL TRAPS AS PER LOCAL PLUMBING CODE REQUIREMENTS.
IV. INSTALLATION OF PIPE SLEEVES
A. INSTALL PIPE SLEEVES AT ALL LOCATIONS WHERE PIPE PASSES THROUGH WALLS, FLOORS, OR CEILINGS
ABOVE OR BELOW GRADE.
B. WHERE SUBJECT TO MOISTURE, SEAL SLEEVES WITH WATER-TIGHT SEALANT.
V. INSTALLATION OF AIR CHAMBERS
A. INSTALL A WATER HAMMER ARRESTOR AT EACH FIXTURE, OR GROUP OF FIXTURES. WATER HAMMER
ARRESTERS, SHALL BE ZURN SHOKTROL SIZED AND INSTALLED PER MANUFACTURER'S
RECOMMENDATION.
VI. INSTALLATION OF FIXTURE TRIM AND FITTINGS
A. INSTALL THE FIXTURE TRIM AND FITTINGS SPECIFIED, TAKING CARE TO PROPERLY ANCHOR EACH
FIXTURE.
B. WHEN THE USE OF A WRENCH IS NECESSARY ON CHROMIUM PLATED PIPING, PROTECT THE PIPE FROM
MARRING BY USE OF FELT OF CLOTH WRAPPING BENEATH WRENCH JAWS.
C. FLEXIBLE SUPPLIES TO FIXTURES SHALL COMPLY WITH ASME A112.18.6, AND ACCESS SHALL BE
PROVIDED PER 2015 IPC.
VII. INSTALLATION OF GAS PIPING
A. INSTALL GAS PIPING IN ACCORDANCE WITH ALL APPLICABLE CODES. INSTALLATION SHALL CONFORM TO
SMACNA GUIDELINES FOR SEISMIC CONSIDERATIONS AT PROJECT LOCATION.
B. PAINT EXPOSED GAS PIPING WITH ONE COAT PRIMER AND TWO COATS OF YELLOW EPOXY.
VIII. INSTALLATION OF PIPE INSULATION
A. INSULATE ALL WATER PIPING AND CONDENSATE DRAINAGE PIPING. ALSO INSULATE ALL DRAIN LINES
FROM ICE BINS.
IX. TESTS AND INSPECTIONS
A. MAKE ALL WATER, AIR AND GAS TESTS OF THE PIPING SYSTEMS IN THE PRESENCE OF AND TO THE
SATISFACTION OF THE OWNER OR HIS DESIGNATED REPRESENTATIVE, AND LOCAL OFFICIALS. CONDUCT
THESE TESTS AT SUCH PLACES AND WITH TIMING TO PERMIT WORK TO PROCEED WITH AS LITTLE
INTERRUPTION AS POSSIBLE. MAKE TEST BEFORE WORK IS CONCEALED.
B. TEST WATER PIPING TO HYDROSTATIC PRESSURE OF 150 PSI AND HOLD FOR 4 HOURS WITH LESS THAN 2
PSI LOSS IN PRESSURE. TEST GAS PIPING AS PER NFPA-54 AND/OR LOCAL AUTHORITY.
C. AFTER THE INSTALLATION OF SANITARY PIPING AND BEFORE THE PIPE IS CONCEALED OR THE FIXTURES
ARE INSTALLED, CAP OR PLUG THE ENDS OF THE SYSTEM AND FILL ALL LINES WITH WATER TO TOP OF
VENTS (BUT NOT LESS THAN 10' OF HEAD), ALLOW TO STAND UNTIL A THOROUGH INSPECTION HAS BEEN
MADE. SHOULD LEAKS APPEAR, MAKE NECESSARY CORRECTIONS AND REPEAT THE TESTS UNTIL THE
SYSTEM IS TIGHT.
D. DO NOT USE RESIN, CANDLE WAX, OR ANY OTHER SUCH SUBSTANCE FOR STOPPING LEADS IN CAST
IRON SOIL, WASTE OR VENT LINES. CAULKING OF SCREW JOINTS TO STOP LEAKS WILL NOT BE
PERMITTED.
E. LABEL ALL VALVES IN EQUIPMENT ROOM AS TO SERVICE AND FUNCTION WITH BRASS TAGS. PLACE ON
VALVES WITH STEEL RINGS. LABEL COLD WATER PIPING, HOT WATER (140°F & 110°F) PIPING, HOT WATER
RETURN PIPING AND GAS PIPING WITH PIPE MARKERS. VALVE LABELS AND PIPE MARKERS SHALL BE SET
ON NAME PLATE.
X. STERILIZATION
A. THE STERILIZATION PROCESS SHALL COMPLY WITH ALL GOVERNING REGULATIONS AND WITH THE
STERILIZATION PROCEDURES RECOMMENDED BY THE AMERICAN WATER WORKS ASSOCIATION. THE
CHLORINATION PROCESS MAY BE SIMPLIFIED BY FIRST FLUSHING THE SYSTEM THOROUGHLY CLEAN,
THEN CHARGING WITH WATER CONTAINING A MINIMUM OF 50 PARTS PER MILLION OF CHLORINE,
ALLOWING THIS TO STAND FOR 24 HOURS, THEN THOROUGHLY FLUSHING. AFTER STERILIZATION AND
FINAL FLUSHING, THE LOCAL HEALTH AUTHORITY IS TO BE NOTIFIED, AND THEIR FINAL APPROVAL
OBTAINED IN WRITING.
PART 1 - GENERAL
DIVISION 22 00 00 - PLUMBING SPECIFICATIONS
PART 2 - PRODUCTS PART 3 - EXECUTION
END OF SECTION 22 00 00
FLUID OPERATING
TEMPERATURE RANGE (°F)
INSULATION CONDUCTIVITY
CONDUCTIVITY
(BTU*in.)/(h*ft2*°F)
MEAN RATING
TEMPERATURE (°F)
NOMINAL PIPE SIZE (INCHES)
d<1 1<d<1-1/2 1-1/2<d<4 4<d<8
> 350 0.32 -0.34 250 4.5 5.0 5.0 5.0
251 -350 0.29 -0.32 200 3.0 4.0 4.5 4.5
201 -250 0.27 -0.30 150
141 -200 0.25 -0.29 125
105 -140 0.21 -0.28 100
40 -60 0.21 -0.27 75
< 40 0.20 -0.26 50
2.5 2.5 2.5 3.0
1.5 1.5 2.0 2.0
1.0 1.0 1.5 1.5
0.5 0.5 1.0 1.0
0.5 1.0 1.0 1.0
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P001
PLUMBING
SPECIFICATIONS
SD
MB
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1
1 ABCO COMMENTS 02/02/2023
GARAGE
6
GARAGE
7
GARAGE
5
GARAGE
4
GARAGE
3
GARAGE
2
4"SAN2"SAN2"SAN3"SAN3"SAN
3"SAN
6"SAN 2"SAN2"SAN2"SAN3"SAN 3"SAN3"SAN
4"SAN 4"SAN
3"SAN3"SAN3"SAN2"SAN3"SAN2"SAN
3"SAN
3"SAN3"SANDGCO
3"3"3"3"SAN
2"SAN
3"3"1
2
2"SAN
1 1/2"V
1 1/2"V
1 1/2"V2"SAN1 1/2"V
4"SAN
4"FCO 4"SAN4"SAN4"FSSTORAGE
160
MECH
70
STORAGE
161
STORAGE
162
STORAGE
163
STORAGE
164
STORAGE
165
STORAGE
166 MECHANICAL
ROOM
167
STORAGE
168
STORAGE
170
SOLAR INVERTER
169
2"V
3"SAN3"SAN3"SAN3"SAN6"SAN 6"SAN 6"SAN 4"SAN
2"SAN
3
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P100
PLUMBING FLOOR
PLANS - BELOW
FLOOR
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
KEYED NOTES
1 SEE CIVIL PLANS FOR CONTINUATION OF BUILDING SEWER.
2 COORDINATE INSTALLATION OF GRADE CLEAN-OUT OUT SIDE OF BUILDING,
IF IN IN DRIVE AREA PROVIDE CAP FLUSH TO CONCRETE, SELECTION AND
FINISH TO BE CONFIRMED WITH ARCHITECT PRIOR TO ORDER.
3 SEE CIVIL PLANS FOR CONTINUATION OF FIRE/DOMESTIC SERVICE.
X
1/4" = 1'-0"1 PLUMBING PLAN - BELOW FLOOR
2
2 VE CHANGES 03/03/23
1. GENERAL REQUIREMENTS FOR PLUMBING PLANS. APPLY TO ALL SHEETS, BUT
ONLY NOTED HERE. REVIEW PROVIDED PLUMBING SPECIFICATIONS FOR MORE
INFORMATION.
2. COORDINATE ALL PLUMBING DROPS, FIXTURES, PIPE PENETRATIONS WITH
WALL TYPE, FLOOR TYPE, AND FOUNDATION WALLS/FOOTINGS WITH
ARCHITECTURE AND STRUCTURAL; CONTRACTOR RESPONSIBLE FOR
COORDINATING REQUIRED WALL THICKNESS FOR PLUMBING DROPS AND
FIXTURES.
3. ALL DOMESTIC WATER PIPES SIZED FOR DISTRIBUTION INDICATED, SEE UNIT
PLANS FOR DISTRIBUTION TO FIXTURES; SEE ISOMETRIC VIEW FOR FULL
LAYOUTS
4. PLUMBING CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITY
CONNECTIONS PRIOR TO THE START OF WORK.
5. ALL UNIONS, VALVES, EQUIPMENT, AND SERVICEABLE PLUMBING SYSTEM
COMPONENTS SHALL BE READILY ACESSIBLE.
6. INSULATE ALL DOMESTIC WATER PIPING PER SPECIFICATION AND LOCAL
CODE.
7. PROVIDE WATER HAMMER ARRESTORS FOR ALL FAST-CLOSING AND
ELECTRONIC VALVES PER IPC AND WHERE NOTED ON PLANS.
8. REFER TO STRUCTURAL PLANS FOR NOTCHING AND CUTTING DETAILS
NEEEDED FOR PLUMBING PENETRATIONS
GENERAL NOTES:
1"CW
1"CW1 1/2"CW1
2
1 3
2
WH-1
2"SAN
3 3
3 2
4
4
3"SAN 3"SAN
3"SAN
WCO
WCO
2"V
2"SAN
WCO
WCO
2"V
3"SAN
WCO WCO
3"SAN
WCO
WCO
1
1
5
1
2" DOMESTIC METER
ASSEMBLY
4" COMBINATION FIRE -
DOMESTIC ENTRY
MECH
38
WH-1
1"CW2"SAN
1 1/2"V1 1/2"V 6
6
6
7
DGCO
DBP-1
HT-1
RPBP-1
DCBP-1
3/4"CW
STORAGE
160
STORAGE
161
STORAGE
162
STORAGE
163
STORAGE
164
STORAGE
165
STORAGE
166
STORAGE
170
STORAGE
168
MECHANICAL
ROOM
167
SOLAR INVERTER
169
2"CW2"CW2"CW2"CW
3/4"CW
1"CW
4"FCO
2"V5
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P101
PLUMBING FLOOR
PLANS - LEVEL 1.1
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
KEYED NOTES
1 3" SAN STACK DN FROM BATHROOM GROUPS ABOVE.
2 3" SAN STACK DN FROM WASHERS ABOVE.
3 2" SAN STACK DN FROM FLOOR DRAINS ABOVE.
4 2" SAN STACK DN FROM KITCHEN SINKS ABOVE.
5 3" SANITARY LINES FROM BATHROOM GROUPS ABOVE, OFFSET TO UPRIGHT
WYE FITTING IN WALL; SEE ISOMETRIC FOR MORE INFORMATION.
6 1"CW STUB-INS TO EACH UNIT WITH SHUT-OFF VALVES; SEE PLUMBING UNIT
PLANS FOR CONTINUATION, SEE PLUMBING ISOMETRICS FOR FULL LAYOUT.
7 DOMESTIC COLD WATER RISER UP IN WALL; SEE CW ISOMETRIC FOR FULL
LAYOUT. PROVIDE SHUT-OFF VALVES WITH ACCESS AT THE BASE OF ALL
DOMESTIC RISERS PER IPC 606.
X
1/4" = 1'-0"1 PLUMBING FLOOR PLAN - LEVEL 1.1
2
2 VE CHANGES 03/03/23
1 3 4 6
F
E
2 5
GARAGE
2
GARAGE
3
GARAGE
4
GARAGE
5
GARAGE
6
GARAGE
7
1/2"CW
3/4"HW
1/2"HW
2"SAN
2"SAN 2"SAN
2"SAN
1/2"CW
3/4"HW
1/2"HW
2"SAN
2"SAN
3"SAN UP TO WCO 3"SAN UP TO WCO
2"SAN
2"SAN
11
SEE PLUMBING UNIT
PLAN P404 FOR IN UNIT
DISTRIBUTION OF
SANITARY PIPING; SEE
SHEET P101 FOR
PLUMBING DROPS ON
FIRST FLOOR
SEE PLUMBING UNIT
PLAN P404 FOR IN UNIT
DISTRIBUTION OF
SANITARY PIPING; SEE
SHEET P101 FOR
PLUMBING DROPS ON
FIRST FLOOR
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P102
PLUMBING FLOOR
PLANS - LEVEL1.2
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
KEYED NOTES
1 DOMESTIC PLUMBING LINES LOCATED IN GARAGE PLENUM SPACE TO BE
INSTALLED ABOVE INSULATION WITHIN BUILDING THERMAL ENVELOPE.
PROVIDE PIPE INSULATION AND ELECTRIC HEAT TRACE FOR FREEZE
PROTECTION. SYSTEM TO BE LAID OUT IN FIELD PER FINAL PIPING
INSTALLATION. HEAT TRACE TO BE MAXIMUM 8W/LF AND SELF-REGULATING
WITH INTEGRAL CONTROLS/SHUT-OFF AS REQUIRED BY IECC.
XKEYED NOTES
1 DOMESTIC PLUMBING LINES LOCATED IN GARAGE PLENUM SPACE TO BE
INSTALLED ABOVE INSULATION WITHIN BUILDING THERMAL ENVELOPE.
PROVIDE PIPE INSULATION AND ELECTRIC HEAT TRACE FOR FREEZE
PROTECTION. SYSTEM TO BE LAID OUT IN FIELD PER FINAL PIPING
INSTALLATION. HEAT TRACE TO BE MAXIMUM 8W/LF AND SELF-REGULATING
WITH INTEGRAL CONTROLS/SHUT-OFF AS REQUIRED BY IECC.
X
1/4" = 1'-0"1 PLUMBING FLOOR PLAN - LEVEL 1.2
A
1 3
D
4 6
F
B
C
E
2 5
1"CW 1 1/4"CW1 1/4"CW
2"V
3"SAN
3"SAN 3"SAN
2"SAN
2"SAN 3"SAN
2"V
3"SAN 3"SAN
1 1/2"V
2"V
3"SAN
3"SAN
1 1/4"CW1 1/4"CW
2"SAN
2"SAN
2"SAN 2"SAN
1 1
2 2
2
2"V
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P103
PLUMBING FLOOR
PLANS - LEVEL 2.1
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 PLUMBING FLOOR PLAN - LEVEL 2.1
KEYED NOTES
1 1"CW STUB-INS TO EACH UNIT WITH SHUT-OFF VALVES; SEE PLUMBING UNIT
PLANS FOR CONTINUATION, SEE PLUMBING ISOMETRICS FOR FULL LAYOUT.
2 DOMESTIC COLD WATER RISER UP IN WALL; SEE CW ISOMETRIC FOR FULL
LAYOUT. PROVIDE SHUT-OFF VALVES WITH ACCESS AT THE BASE OF ALL
DOMESTIC RISERS PER IPC 606.
XKEYED NOTES
1 1"CW STUB-INS TO EACH UNIT WITH SHUT-OFF VALVES; SEE PLUMBING UNIT
PLANS FOR CONTINUATION, SEE PLUMBING ISOMETRICS FOR FULL LAYOUT.
2 DOMESTIC COLD WATER RISER UP IN WALL; SEE CW ISOMETRIC FOR FULL
LAYOUT. PROVIDE SHUT-OFF VALVES WITH ACCESS AT THE BASE OF ALL
DOMESTIC RISERS PER IPC 606.
X
2
2 VE CHANGES 03/03/23
1 3
D
4 6
F
E
2 5
2"V
3"SAN
3"SAN
3"SAN3"SAN
2"SAN 2"SAN
3"SAN
1 1
2 2
2"V
3"SAN
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P104
PLUMBING FLOOR
PLANS - LEVEL 2.2
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 PLUMBING FLOOR PLAN - LEVEL 2.2
KEYED NOTES
1 1"CW STUB-INS TO EACH UNIT WITH SHUT-OFF VALVES; SEE PLUMBING UNIT
PLANS FOR CONTINUATION, SEE PLUMBING ISOMETRICS FOR FULL LAYOUT.
2 DOMESTIC COLD WATER RISER UP IN WALL; SEE CW ISOMETRIC FOR FULL
LAYOUT. PROVIDE SHUT-OFF VALVES WITH ACCESS AT THE BASE OF ALL
DOMESTIC RISERS PER IPC 606.
XKEYED NOTES
1 1"CW STUB-INS TO EACH UNIT WITH SHUT-OFF VALVES; SEE PLUMBING UNIT
PLANS FOR CONTINUATION, SEE PLUMBING ISOMETRICS FOR FULL LAYOUT.
2 DOMESTIC COLD WATER RISER UP IN WALL; SEE CW ISOMETRIC FOR FULL
LAYOUT. PROVIDE SHUT-OFF VALVES WITH ACCESS AT THE BASE OF ALL
DOMESTIC RISERS PER IPC 606.
X
2
2 VE CHANGES 03/03/23
A
1 3
D
4 6
F
B
C
E
2 5
11
1"CW
2
33
4 4
2 2
4
4
4 4
1 1/2"V
1"CW1"CW
3"V
2"V 2"V
3"V
3 3
5
5 5
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P105
PLUMBING FLOOR
PLANS - LEVEL 3.1
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 PLUMBING FLOOR PLAN - LEVEL 3.1
KEYED NOTES
1 1"CW STUB-INS TO EACH UNIT WITH SHUT-OFF VALVES; SEE PLUMBING UNIT
PLANS FOR CONTINUATION, SEE PLUMBING ISOMETRICS FOR FULL LAYOUT.
2 2" VENT STACK UP TO 3"VTR.
3 2" STACK VENT UP TO 3"VTR.
4 3" STACK VENT UP TO 3"VTR.
5 DOMESTIC COLD WATER RISER UP IN WALL; SEE CW ISOMETRIC FOR FULL
LAYOUT. PROVIDE SHUT-OFF VALVES WITH ACCESS AT THE BASE OF ALL
DOMESTIC RISERS PER IPC 606.
XKEYED NOTES
1 1"CW STUB-INS TO EACH UNIT WITH SHUT-OFF VALVES; SEE PLUMBING UNIT
PLANS FOR CONTINUATION, SEE PLUMBING ISOMETRICS FOR FULL LAYOUT.
2 2" VENT STACK UP TO 3"VTR.
3 2" STACK VENT UP TO 3"VTR.
4 3" STACK VENT UP TO 3"VTR.
5 DOMESTIC COLD WATER RISER UP IN WALL; SEE CW ISOMETRIC FOR FULL
LAYOUT. PROVIDE SHUT-OFF VALVES WITH ACCESS AT THE BASE OF ALL
DOMESTIC RISERS PER IPC 606.
X
2
2 VE CHANGES 03/03/23
1 3
D
4 6
F
E
2 5
2"V2"V
2"V
2"V1 1
221 1
11
1"CW 1"CW 2"Vstudio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P106
PLUMBING FLOOR
PLANS - LEVEL 3.2
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 PLUMBING FLOOR PLAN - LEVEL 3.2
KEYED NOTES
1 3" STACK VENT UP TO 3"VTR.
2 1"CW STUB-INS TO EACH UNIT WITH SHUT-OFF VALVES; SEE PLUMBING UNIT
PLANS FOR CONTINUATION, SEE PLUMBING ISOMETRICS FOR FULL LAYOUT.
XKEYED NOTES
1 3" STACK VENT UP TO 3"VTR.
2 1"CW STUB-INS TO EACH UNIT WITH SHUT-OFF VALVES; SEE PLUMBING UNIT
PLANS FOR CONTINUATION, SEE PLUMBING ISOMETRICS FOR FULL LAYOUT.
X
2
2 VE CHANGES 03/03/23
A
1 3
D
4 6
F
B
C
E
2 5
3"VTR
3"VTR
3"VTR
3"VTR
3"VTR
3"VTR
3"VTR3"VTR
3"VTR
3"VTR
3"VTR
3"VTR
3"VTR
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P107
PLUMBING FLOOR
PLANS - ROOF
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 PLUMBING ROOF PLAN
3/4"HW1/2"CW1
2
IMB-1
WB-1
2"SAN3"SAN3"SAN2"SAN
2"SAN
3"SAN 3"SAN3
4
L-1
WC-1
S-1
3"SAN 3"SANWCO
SEE BUILDING PLANS
FOR CONTINUATION;
TYPICAL
1 1/2"V
SEE BELOW FLOOR PLAN FOR
CONTINUATION OF BELOW
GRADE SANITARY PIPING;
TYPICAL
WCO
2"V
3"SAN 3"SAN
WCO
1 1/2"V 3/4"HW5
6
3"SAN
1"CWTEA-1
EWH-1
FD-1
3/4"HW
1/2"CW
1"HW
1"HW
1"CW1"CW
1/2"CW3/4"CWBT-1
WCO2"SAN2"SANTMV-1
2"SAN STACK DN FROM
KITCHEN SINKS ABOVE,
OFFSET TO WALL AND
DROP BELOW GRADE;
PROVIDE CLEANOUT
3"SAN
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P401
PLUMBING - UNIT
PLANS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/2" = 1'-0"1 PLUMBING UNIT PLAN - 2 BEDROOM TYPE 6
KEYED NOTES
1 CONNECT 1/2"HW TO DISHWASHER WITH ANGLE VALVE AND SIZE "AA"
SHOCK ARRESTOR, ROUTE DISHWASHER DRAIN TO GARBAGE DISPOSAL
THROUGH SINK-DECK MOUNTED AIR GAP FITTING OR HIGH LOOP.
2 1-1/2"V UP TO AIR ADMITTANCE VALVE LOCATED BENEATH SINK IN
CASEWORK OR HALF WALL, WITH ACCESS. COORDINATE INSTALLATION
WITH MILLWORK PROVIDER; PROVIDE CLEANOUT IN CABINET FOR KITCHEN
WASTE LINE.
3 HORIZONTAL WET VENT FOR BATHROOM GROUPS ABOVE, IPC SECTION
912.1; PROVIDE CLEANOUT IN LAVATORY CABINET FOR WASTE LINE.
4 1/2"CW & 3/4"HW DROP IN WALL, DN BELOW FLOOR AND OFFSET IN
MILLWORK OR PENINSULA HALF WALL TO KITCHEN SINK.
5 MECHANICAL / PLUMBING EQUIPMENT LAYOUT IN UTILITY CLOSETS TO BE
FIELD COORDINATED. FINAL AVAILABLE SPACE TO BE COORDINATED WITH
ARCHITECTURAL DRAWINGS AND REQUIRED EQUIPMENT CLEARANCES.
6 PROVIDE FULL SIZED SHUT-OFF VALVE WHERE CW PIPE ENTERS UNIT.
PROVIDE ACCESS PANEL IN WALL AS REQUIRED. FINAL LOCATION TO BE
VERIFIED.
X
GENERAL REQUIREMENTS FOR PLUMBING UNIT PLANS. APPLY TO ALL SHEETS,
BUT ONLY NOTED HERE. REVIEW PROVIDED PLUMBING SPECIFICATIONS FOR
MORE INFORMATION.
COORDINATE ALL PLUMBING DROPS AND PIPE PENETRATIONS WITH WALL TYPE
AND ARCHITECTURE; CONTRACTOR RESPONSIBLE FOR COORDINATING
REQUIRED WALL THICKNESS FOR PLUMBING DROPS.
ALL DOMESTIC WATER PIPES SIZED FOR DISTRIBUTION INDICATED, OFFSET
DOWN IN WALL TO FIXTURE. FINAL FIXTURE CONNECTION SIZE PER SCHEDULE
UNLESS OTHER WISE NOTED; COORDINATE WITH ARCHITECTURE FOR EXACT
FIXTURE LOCATION AND CONFIGURATION.
HOT WATER RECIRCULATION PIPING TO BE INSTALLED PER 2015 IPC & IECC;
TOTAL LENGTH OF PIPING TO FROM HOT WATER SOURCE TO FARTHEST FIXTURE
SHALL NOT EXCEED 50 FT.
PLUMBING CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNIT
CONNECTIONS PRIOR TO THE START OF WORK.
ALL UNIONS, VALVES, EQUIPMENT, AND SERVICEABLE PLUMBING SYSTEM
COMPONENTS SHALL BE READILY ACESSIBLE.
INSULATE ALL DOMESTIC WATER PIPING PER SPECIFICATION AND LOCAL CODE.
PROVIDE WATER HAMMER ARRESTORS FOR ALL FAST-CLOSING AND
ELECTRONIC VALVES PER IPC AND WHERE NOTED ON PLANS.
REFER TO STRUCTURAL PLANS FOR NOTCHING AND CUTTING DETAILS NEEEDED
FOR PLUMBING PENETRATIONS
GENERAL NOTES:
2
2 VE CHANGES 03/03/23
GDU-1
S-1
IMB-1
3/4"HW
3/4"CW
L-1
WC-1
BT-1
3"SAN1
2
1 1/2"V
3/4"CW
2"SAN
2"SAN STACK DN
FROM FLOOR
DRAINS ABOVE
1 1/2"V
EWH-1
TEA-1
DCP-1
FD-1TMV-1 2"SAN1/2"HWC
3/4"HW
1"CW
1"HW
1/2"HWC
3/4"CW
SEE BELOW FLOOR PLAN
FOR CONTINUATION OF
BELOW GRADE SANITARY
PIPING; TYPICAL
WCO
SEE BELOW FLOOR PLAN
FOR CONTINUATION OF
BELOW GRADE SANITARY
PIPING; TYPICAL
3
4
2"SAN STACK DN FROM
KITCHEN SINKS ABOVE, DN IN
WALL TO BELOW GRADE;
PROVIDE CLEANOUT
1"HW
1"CW
1/2"HWC
2"SAN STACK DN
FROM FLOOR
DRAINS ABOVE
1 1/2"V
1 1/2"V1 1/2"V3"SAN3"SAN
2"SAN 3"SANWB-1
3"SAN 2"SAN
1 1/2"V
3"SANstudio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P402
PLUMBING - UNIT
PLANS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/2" = 1'-0"1 PLUMBING UNIT PLAN - 1 BEDROOM TYPE 2
KEYED NOTES
1 CONNECT 1/2"HW TO DISHWASHER WITH ANGLE VALVE AND SIZE "AA"
SHOCK ARRESTOR, ROUTE DISHWASHER DRAIN TO GARBAGE DISPOSAL
THROUGH SINK-DECK MOUNTED AIR GAP FITTING OR HIGH LOOP.
2 HORIZONTAL WET VENT FOR BATHROOM GROUPS ABOVE, IPC SECTION
912.1; PROVIDE CLEANOUT IN LAVATORY CABINET FOR WASTE LINE.
3 MECHANICAL / PLUMBING EQUIPMENT LAYOUT IN UTILITY CLOSETS TO BE
FIELD COORDINATED. FINAL AVAILABLE SPACE TO BE COORDINATED WITH
ARCHITECTURAL DRAWINGS AND REQUIRED EQUIPMENT CLEARANCES.
4 PROVIDE FULL SIZED SHUT-OFF VALVE WHERE CW PIPE ENTERS UNIT.
PROVIDE ACCESS PANEL IN WALL AS REQUIRED. FINAL LOCATION TO BE
VERIFIED.
X
2
2 VE CHANGES 03/03/23
2"SAN3/4"HW1/2"CW1/2"CW1"HW
1/2"HWC
1"CW
1/2"HWC
1"HW
1"CW
3/4"HW
3/4"
L-1
WC-1 BT-1
WB-1
1/2"CW
1/2"HW
1 1/2"V
2"V
EWH-2
TEA-1
TMV-1
DCP-1
WC-1
SH-1
L-1
IMB-1
3/4"HW
1/2"CW
S-1
GDU-1
3"SAN
2"SAN
3"SAN
1
2
3
4
5
FD-1
2"SAN
1"CW
2"V
1 1/2"V
5
6
SEE BUILDING PLANS FOR
CONTINUATION OF
BUILDING PIPING
1"HW3"SAN 2"SAN3/4"HW3/4"CW1/2"CW3"SAN
3/4"CW
1/2"HW
3"SAN 1 1/2"V
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P403
PLUMBING - UNIT
PLANS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/2" = 1'-0"1 PLUMBING UNIT PLAN - 2 BEDROOM TYPE 5
KEYED NOTES
1 1/2"CW & 3/4"HW DROP IN WALL, DN BELOW FLOOR AND OFFSET IN
MILLWORK OR PENINSULA HALF WALL TO KITCHEN SINK.
2 1-1/2"V UP TO AIR ADMITTANCE VALVE LOCATED BENEATH SINK IN
CASEWORK OR HALF WALL, WITH ACCESS. COORDINATE INSTALLATION
WITH MILLWORK PROVIDER; PROVIDE CLEANOUT IN CABINET FOR KITCHEN
WASTE LINE.
3 CONNECT 1/2"HW TO DISHWASHER WITH ANGLE VALVE AND SIZE "AA"
SHOCK ARRESTOR, ROUTE DISHWASHER DRAIN TO GARBAGE DISPOSAL
THROUGH SINK-DECK MOUNTED AIR GAP FITTING OR HIGH LOOP.
4 MECHANICAL / PLUMBING EQUIPMENT LAYOUT IN UTILITY CLOSETS TO BE
FIELD COORDINATED. FINAL AVAILABLE SPACE TO BE COORDINATED WITH
ARCHITECTURAL DRAWINGS AND REQUIRED EQUIPMENT CLEARANCES.
5 HORIZONTAL WET VENT FOR BATHROOM GROUPS ABOVE, IPC SECTION
912.1; PROVIDE CLEANOUT IN LAVATORY CABINET FOR WASTE LINE.
6 PROVIDE FULL SIZED SHUT-OFF VALVE WHERE CW PIPE ENTERS UNIT.
PROVIDE ACCESS PANEL IN WALL AS REQUIRED. FINAL LOCATION TO BE
VERIFIED.
X
2
2 VE CHANGES 03/03/23
S-1
GDU-1
IMB-1
2"SAN1/2"CW
1/2"HW
3/4"HW
3"SAN
TEA-1
EWH-2
TMV-1
2"SAN
3"SAN
DCP-1
FD-1
1 1/4"CW
1"HW
1/2"HWC
1"CW 1"CWWB-1
WC-1
WC-1
BT-1
L-1
L-1L-1
SH-1
3"SAN
3/4"HW
3/4"HW
3/4"CW
3/4"CW
1 1/2"V
2"SAN
2"V 1 1/2"V
2"SAN
2"SAN
2"SAN
WCO
2"SAN3"SAN
1/2"CW
3/4"HW
1 1/2"V
1
2
3
4
5
55
1/2"HWC1/2"CW3/4"HW3"SAN
1"HW
1"CW
1/2"HW
1/2"CW
6
SEE BUILDING PLANS
FOR CONTINUATION
OF BUILDING PIPING;
TYPICAL
2"SAN 5
7
3"SAN
1/2"HWC
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P404
PLUMBING - UNIT
PLANS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/2" = 1'-0"1 PLUMBING UNIT PLAN - 2 BEDROOM TYPE 4
KEYED NOTES
1 1/2"CW & 3/4"HW DROP IN WALL, DN BELOW FLOOR AND OFFSET IN
MILLWORK OR PENINSULA HALF WALL TO KITCHEN SINK.
2 1-1/2"V UP TO AIR ADMITTANCE VALVE LOCATED BENEATH SINK IN
CASEWORK OR HALF WALL, WITH ACCESS. COORDINATE INSTALLATION
WITH MILLWORK PROVIDER; PROVIDE CLEANOUT IN CABINET FOR KITCHEN
WASTE LINE.
3 CONNECT 1/2"HW TO DISHWASHER WITH ANGLE VALVE AND SIZE "AA"
SHOCK ARRESTOR, ROUTE DISHWASHER DRAIN TO GARBAGE DISPOSAL
THROUGH SINK-DECK MOUNTED AIR GAP FITTING OR HIGH LOOP.
4 MECHANICAL / PLUMBING EQUIPMENT LAYOUT IN UTILITY CLOSETS TO BE
FIELD COORDINATED. FINAL AVAILABLE SPACE TO BE COORDINATED WITH
ARCHITECTURAL DRAWINGS AND REQUIRED EQUIPMENT CLEARANCES.
5 HORIZONTAL WET VENT FOR BATHROOM GROUPS ABOVE, IPC SECTION
912.1; PROVIDE CLEANOUT IN LAVATORY CABINET FOR WASTE LINE.
6 PROVIDE FULL SIZED SHUT-OFF VALVE WHERE CW PIPE ENTERS UNIT.
PROVIDE ACCESS PANEL IN WALL AS REQUIRED. FINAL LOCATION TO BE
VERIFIED.
7 DOMESTIC COLD WATER RISER UP IN WALL; SEE CW ISOMETRIC FOR FULL
LAYOUT. PROVIDE SHUT-OFF VALVES WITH ACCESS AT THE BASE OF ALL
DOMESTIC RISERS PER IPC 606.
X
2
2 VE CHANGES 03/03/23
3"SAN1"HW 3"SAN2"SAN2"SAN2"SAN1/2"CW3/4"HWS-1
GDU-1
WC-1
L-1
BT-1
WB-1
IMB-1 1/2"CW3/4"HW1 1/2"V3"SAN3"SAN3"SAN
FD-1
SEE BUILDING PLANS
FOR CONTINUATION;
TYPICAL
SEE BELOW FLOOR PLAN
FOR CONTINUATION OF
BELOW GRADE SANITARY
PIPING; TYPICAL
1
2
3
4
5
2"V
1 1/2"V 3"SAN
2"SAN
2"SAN1"CW3"SAN
2"V3"SAN3"SAN3"SAN
2"SAN
2"SAN
TMV-1
EWH-1
TEA-1
4"SAN3"SAN
3"SAN
2"SAN STACK DN FROM
KITCHEN SINKS ABOVE, DN
IN WALL TO BELOW GRADE;
PROVIDE CLEANOUT
6
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P405
PLUMBING - UNIT
PLANS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/2" = 1'-0"1 PLUMBING UNIT PLAN - 1 BEDROOM TYPE 1
KEYED NOTES
1 1/2"CW & 3/4"HW DROP IN WALL, DN BELOW FLOOR AND OFFSET IN
MILLWORK OR PENINSULA HALF WALL TO KITCHEN SINK.
2 1-1/2"V UP TO AIR ADMITTANCE VALVE LOCATED BENEATH SINK IN
CASEWORK OR HALF WALL, WITH ACCESS. COORDINATE INSTALLATION
WITH MILLWORK PROVIDER; PROVIDE CLEANOUT IN CABINET FOR KITCHEN
WASTE LINE.
3 CONNECT 1/2"HW TO DISHWASHER WITH ANGLE VALVE AND SIZE "AA"
SHOCK ARRESTOR, ROUTE DISHWASHER DRAIN TO GARBAGE DISPOSAL
THROUGH SINK-DECK MOUNTED AIR GAP FITTING OR HIGH LOOP.
4 HORIZONTAL WET VENT FOR BATHROOM GROUPS ABOVE, IPC SECTION
912.1; PROVIDE CLEANOUT IN LAVATORY CABINET FOR WASTE LINE.
5 PROVIDE FULL SIZED SHUT-OFF VALVE WHERE CW PIPE ENTERS UNIT.
PROVIDE ACCESS PANEL IN WALL AS REQUIRED. FINAL LOCATION TO BE
VERIFIED.
6 MECHANICAL / PLUMBING EQUIPMENT LAYOUT IN UTILITY CLOSETS TO BE
FIELD COORDINATED. FINAL AVAILABLE SPACE TO BE COORDINATED WITH
ARCHITECTURAL DRAWINGS AND REQUIRED EQUIPMENT CLEARANCES.
X
2
2 VE CHANGES 03/03/23
1 1 /2 "C W1 1/2"CW1"C
W
1 "C W
1 1 /4 "C W1 1/4"CW1 1/4"C
W
1 1/4"CW1"CW1"CW1"C
W
1"C
W
1 "C W
1 "C W
1 "C W
1 1/2"CW
1"C
W
1"CW TO REMOTE-MOUNT 23-GALLON
HYDROCUMULATOR TANK FOR
BOOSTER PUMP SYSTEM
1"CW STUBS WITH
SHUT-OFF VALVE TO
EVERY UNIT, TYPICAL3/4"CWWH-1
SEE CIVIL PLANS
FOR CONTINUATION
OF 4" COMBINATION
FIRE-DOMESTIC
SERVICE
1 1/4"C
W
4" COMBINATION
FIRE -DOMESTIC
ENTRY
2" DOMESTIC METER ASSEMBLY; CONTRACTOR TO
VERIFY ASSEMBLY REQUIREMENTS WITH WATER
DISTRICT AND PROVIDE ALL NECESSARY
COMPONENTS TO THE SATISFACTION OF THE IAHJ
3/4"C
W
1 "C W
WH-1
DBP-1
HT-1
RPBP-1
4"FS2"FS2"CW2"C
W
2"C
W
4"FS1 1/4"CW1"CW STUBS WITH
SHUT-OFF VALVE TO
EVERY UNIT, TYPICAL
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P406
PLUMBING
ISOMETRICS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1 DOMESTIC COLD WATER RISER DIAGRAM
2
2 VE CHANGES 03/03/23
2"SAN
2 "S A N 3"SA
N
3 "S A N
6"SA
N
3 "S A N
3 "S A N3"SAN3 "S A N 2"SAN2 "S A N
3 "S A N
3 "S A N
1 1/2"V1 1/2"V1 1/2"V
S-1
GDU-1
WC-1
L-1
BT-1
WCO
WCO
WB-1 3"SAN3"SAN STACKS DOWN FROM
BATHROOM GROUPS ABOVE
2"VENT UP IN
WALL OF UNITS
ABOVE
SEE BUILDING PLANS
FOR CONTINUATION
OF BUILDING PIPING
BELOW GRADE
3"SAN STACK DOWN
FROM ABOVE
6"SA
N
1-1/2"V UP
TO AAV
2"SAN STACK DN
FROM KITCHEN
SINKS ABOVE
WCO
WCO 2"SANWCO
2"SAN2"SA
N 3"SAN3 "S A N
6"SA
N
FD-1
1 1/2"V1 1/2"V
3"SA
N
SEE BUILDING PLANS
FOR CONTINUATION
OF BUILDING PIPING
BELOW GRADE
2"SA
N
2"SAN2"SAN3 "S A N
2"SAN
3 "S A N
2"SAN2"SAN1 1/2"V2"SA
N2"SANS-1
GDU-1
WC-1
L-1
BT-1
WB-1
2"SANFD-1
WCO
2"SA
N
1 1/2"V
2"SAN DN IN
WALL FROM
KITCHEN SINKS
IN UNITS ABOVE
2"SAN DN IN
WALL FROM
FLOOR DRAINS
IN UNITS ABOVE
1-1/2"V UP IN WALL
TO UNITS ABOVE
1-1/2"V UP IN WALL
TO UNITS ABOVE
SEE BUILDING PLANS
FOR CONTINUATION
OF BUILDING PIPING
BELOW GRADE
SEE BUILDING PLANS
FOR CONTINUATION
OF BUILDING PIPING
BELOW GRADE1 1/2"VSEE BUILDING PLANS
FOR CONTINUATION
OF BUILDING PIPING
BELOW GRADE
2"SAN DN IN
WALL FROM
FLOOR DRAINS
IN UNITS ABOVE
3"SAN3 "S A N 2"SAN2"SAN3"SAN1 1/2"V1 1/2"VWCO
WCO
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P407
PLUMBING
ISOMETRICS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1 1 BD TYPE 6 WASTE AND VENT ISOMETRIC
2 1 BD TYPE 2 WASTE AND VENT ISOMETRIC
2
2
2 VE CHANGES 03/03/23
S-1
GDU-1
WC-1
L-1
BT-1
2"SAN DN IN
WALL FROM
KITCHEN SINK IN
UNIT ABOVE
1-1/2"V UP IN WALL
FROM UNIT BELOW
2"V UP IN WALL TO
UNITS ABOVE
2"SA
N 2"SAN2"SAN3"SA
N3"SAN2"SAN2 "S A N3"SAN3"SA
N3"SAN3"V1 1/2"V2"V2"V3"SAN2"SAN2"V2"SANWC-1
L-1
SH-1
FD-1
2"SAN FROM
KITCHEN SINKS
DN IN WALL TO
UNIT BELOW
3"SAN FROM BATHROOM
GROUPS DN IN WALL TO
UPRIGHT WYE IN UNIT BELOW;
SEE SHEET P407
2"V RISE TO 3"VTR; SEE
BUILIDING PLANS FROM VENT
PIPE ROUTINGS AND ROOF
TERMINATIONS
3"V RISE TO 3"VTR; SEE
BUILIDING PLANS
FROM VENT PIPE
ROUTINGS AND ROOF
TERMINATIONS
2"V RISE TO 3"VTR; SEE
BUILIDING PLANS FOR VENT
PIPE ROUTINGS AND ROOF
TERMINATIONS
3"SAN FROM BATHROOM
GROUPS; DN IN WALL TO
UNITS BELOW
3"SAN FROM WASHERS;
DN IN WALL TO UNITS
BELOW
3"SAN FROM WASHERS;
DN IN WALL TO UNITS
BELOW
3"SAN FROM BATHROOM
GROUPS; DN IN WALL TO
UNITS BELOW
2"SAN FROM FLOOR
DRAINS; OFFSETS IN
CEILING OF UNIT BELOW
WB-1
1-1/2"V UP
TO AAV
2"SA
N1 1/2"V1 1/2"V1-1/2"V UP IN WALL
FROM UNIT BELOW
1-1/2"V RISE COMBINES IN ATTIC SPACE
WITH 2"V RISE FROM FLOOR DRAIN
STACK; SEE BUILIDING PLANS FOR VENT
PIPE ROUTINGS AND ROOF
TERMINATIONS
S-1
GDU-1
WC-1
L-1
SH-1
WB-1
BT-1
WC-1
L-1
WCO
3"SA
N
2 "S A N
2 "S A N
3 "S A N
2 "S A N
2 "S A N
2"SAN3"SAN2"SAN3"SAN1 1/2"V 2"V1 1/2"V2"V2 "V
3"V2"V
3"VTR
3"SAN3"SAN2 "S A N
3 "S A N 2"SAN2"SAN3"VTR
3"V2"V3"SAN2"SAN2"SAN
2"SAN
1 1/2"V
1 1/2"V
3"SAN
3"SAN FROM
WASHER DN IN
WALL TO UNITS
BELOW
2"SAN FROM FLOOR
DRAINS; DN IN WALL
TO UNITS BELOW
FD-1
3"SAN FROM BATHROOM
GROUPS DN IN WALL TO
UNITS BELOW
1-1/2"V UP
TO AAV
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P408
PLUMBING
ISOMETRICS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1 2 BD TYPE 5 WASTE AND VENT ISOMETRIC
2 2 BD TYPE 4 WASTE AND VENT ISOMETRIC
2
2 VE CHANGES 03/03/23
1B15 CLEANOUT
RING AND SOLID
COVER, TYPICAL
56"x24"x6"
CONCRETE PAD
COLLAR, TYPICAL
REINFORCED
CONCRETE WITH #
4 BARS @ 1'-0" O.C.
4" HDPE OR
CAST IRON
PIPE, TYPICAL
PIPING SIZED
PER PLANS
TWO-WAY CLEANOUT
FITTING OR (2)COMBINATION
WYE AND EIGHT BEND
FITTINGS
STEEL PIPE SLEEVE
WELL SEAL (MIDWEST
WELL CO. OR EQUAL)
INTERIOR
FLOOR
GRADE
PIPE
STEEL PIPE SLEEVE
INTERIOR
WALL
EARTH
PIPE
ELASTOMERIC SEAL
ELEMENT, LINKSEAL OR
EQUAL, TYPICAL
PRESSURE PLATE, TYPICAL
BOLT, TYPICAL
MOISTURE BARRIER,
INTEGRAL TO PIPE SLEEVE
NOTE: ELASTOMERIC SEAL ELEMENT,
PRESSURE PLATES, AND BOLTS, TO BE
PROVIDED AS COHESIVE ASSEMBLY
FROM SINGLE MANUFACTURER, AND
INSTALLED FOLLOWING
MANUFACTURER'S RECOMMENDATIONS
STUD
HW SIZED PER
PLANS; SEE
FIXTURE
SCHEDULE
CW SIZED PER
PLANS; SEE
FIXTURE
SCHEDULE
1/4 TURN
VALVE
WATER HAMMER
ARRESTOR
RECESSED
OUTLET BOX;
SEE SCHEDULE
SAN; SEE
FIXTURE
SCHEDULE
FOR SIZE
TRAP
VENT; SEE
FIXTURE
SCHEDULE
FOR SIZE
1/4 TURN
VALVE
CW/HW
SAN
LAG SCREW
SUPPORT
STRAP TO
STUD
WASTE OR VENT
PROVIDE CLEANOUT TEE
WITH SCREWED COUNTER-
SUNK CAST IRON PLUG:
TAPERED THREAD WITH
TFE JOINT COMPOUND
WHERE CLEANOUT TEE IS
CONCEALED IN A CHASE
OR PARTITION, PROVIDE A
ROUND 18 GAUGE
STAINLESS STEEL COVER
WITH BEVELED EDGE
HUB AT FLOOR
RISER LENGTH AS
REQUIRED
WCO, SIZED
PER PLANS
COLUMN OR
PARTITION AS
SHOWN ON
FLOOR PLAN
LONG SWEEP AT
END OF LINE OR
COMBINATION
WYE
DIRECTION
OF FLOW
FLOOR
AS REQUIRED FOR
DEPTH OF SEWER
HUB AND SPIGOT
CAST IRON, OR PVC,
PIPE BELOW FLOOR
SANITARY OR
STORM SEWER LINE
FLOOR
DIRECTION
OF FLOW
MEMBRANE
CLAMP
SAME SIZE AS SEWER
UP TO 4" MAXIMUM
LONG SWEEP ELBOW
AT END OR TURN OF
RUN
COMBINATION WYE AND
EIGHTH BEND IN RUN,
ENTER TOP OF PIPE
MINIMUM 12" ABOVE ROOF
NORMALLY. EXTEND TO
HEIGHT OF PARAPET
WHEN WITHIN 10'-0" OF
PARAPET
ANCHOR PIPE TO ROOF DECK
WITH U-BOLT AROUND PIPE &
ANGLE IRON WELDED OR
SCREWED TO ROOF DECK OR
JOIST. MINIMUM 12" BELOW
ROOF
HUBLESS PIPE
CONNECTORS ON CAST
IRON OR GLUED IF PVC
ROOF DECK
FLASHING & COUNTER
FLASHING OF VTR IS BY
ROOFING CONTRACTOR.
PLUMBING CONTRACTOR
TO COORDINATE INSTALL
CORE DRILL ROOF OR
PROVIDE SLEEVE IF
REQUIRED BY TYPE OF
ROOF DECK. PROVIDE
FIRE STOP SEAL BETWEEN
PIPE & SLEEVE OR DECK
PROVIDE PIPE INCREASER
IF/WHERE CODE REQUIRES
A MINIMUM 3" VENT
THROUGH ROOF
ROOF INSULATION
REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR
MINIMUM THREE FEET FROM PROPERTY LINE, OR FIFTEEN FEET
HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING
OR FRESH AIR INTAKE, OR ONE FOOT FROM ANY VERTICAL SURFACE.
LOCATE VTR MINIMUM 18" FROM PARAPET, EXPANSION JOINT, EQUIPMENT
CURB, ETC. OFFSET IN CELING SPACE WHERE REQUIRED TO MEET THESE
CONDITIONS
STUD
VENT PIPING FROM
PLUMBING FIXTURES;
SEE PLANS FOR SIZE
AIR
ADMITTANCE
VALVE
ACCESSORY GRILL
( MOUNTED IN FRONT OF
WALL BOX)
AAV IN WALL BOX
( FIRE OR NON-
FIRE RATED)
NOTES:
1. AAV MUST CONFORM TO ASSE 1050 OR 1051 & BE MARKED WITH MFR. NAME,
MODEL & CLASSIFICATION. LOCATED NOT LESS THAN 4" ABOVE HORIZONTAL
BRANCH DRAIN OR FIXTURE BEING VENTED AND NOT LESS THAN 6" ABOVE FLOOD
LEVEL RIM OF FIXTURE.
2. MUST BE LOCATED WITHIN THE MAXIMUM DEVELOPED LENGTH PERMITTED FOR
THE VENT AND INSTALLED NO LESS THAN 6" ABOVE INSULATION MATERIALS WHERE
INSTALLED IN ATTICS.
3. AIR GRILLE OR ACCESS PANEL MUST BE INSTALLED TO ENSURE ADEQUATE
VENTILATION FOR PROPER OPERATION; MUST BE ACCESSIBLE FOR INSPECTION,
SERVICE, AND REPAIR OR REPLACEMENT. FOLLOW ALL MANUFACTURERS
INSTALLATION REQUIREMENTS AND APPLICABLE LOCAL CODES.
FLOOR
COUNTERTOP
APPROVED AIR
GAP FITTING
DISPOSER
KITCHEN
SINK DISHWASHER
APPROVED
FLEXIBLE
DISHWASHER
DRAIN LINE
P-TRAP ASSEMBY
TO SANITARY
CONNECTION
WATER HAMMER
ARRESTOR SIZED AND
PLACED IN ACCORDANCE
WITH PDI STANDARD
WH201.
BALL VALVE,
TYP.
SERVICE LINE
SIZED PER PLANS
NOTES:
* WATER HAMMER ARRESTORS SHALL BE
PROVIDED WHERE REQUIRED BY THE IPC 604.9
AND WHERE INDICATED ON THE DRAWINGS
AND AS NECESSARY TO PREVENT WATER
HAMMER FROM OCCURRING ON QUICK
CLOSING DOMESTIC WATER VALVES.
REFER TO PLANS FOR LOCATIONS. WHERE
REQUIRED BUT NOT INDICATED ON PLANS,
INSTALL IN INCONSPICOUS LOCATIONS.
WHERE WALL ACCESS IS REQUIRED BY CODE,
COORDINATE ACCESS PANEL LOCATION WITH
DESIGN TEAM PRIOR TO INSTALLATION.
A MINIMUM OF ONE ARRESTOR SHALL BE
PROVIDED FOR EACH FIXTURE GROUP AND ON
EACH SERVICE TO THAT GROUP.
* A GROUP FOR THIS REQUIREMENT SHALL
MEAN ONE OR MORE FIXTURES THAT CONTAIN
OR MAKE USE OF AN AUTOMATIC VALVE.
1"CW
1"CW1"CW1"HW1"HW (110°)
HOSE END
DRAIN
VALVE,
TYPICAL
ASME T&P
RELIEF
VALVE
LINE SIZE BALL
VALVE, TYPICAL
THERMAL
EXPANSION
ABSORBER, TEA-1,
HUNG FROM
STRUCTURE
THERMOMETER,
TYPICAL
THERMOSTATIC
MIXING VALVE,
TMV-1
UNION, TYPICAL
CHECK VALVE,
TYPICAL
ELECTRIC
WATER HEATER
EWH-1, -2
TIGHT CLOSING
BALANCING
VALVE
DOMESTIC HOT
WATER
RECIRCULATION
PUMP, DCP-1
1/2"HWC
ATMOSPHERIC
VACUUM BREAKER
WATER HEATER DRAIN PAN
PIPED TO FLOOR DRAIN
1 TWO-WAY GRADE CLEANOUT DETAIL
5 SLEEVE/SEAL THRU FLOOR DETAIL 6 PIPE SEAL THRU WALL DETAIL 7 WASHING MACHINE BOX DETAIL
2 TYPICAL WALL CLEANOUT DETAIL 3 TYPICAL FLOOR/GRADE CLEANOUT DETAIL 4 VENT THRU ROOF DETAIL
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P501
PLUMBING
DETAILS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
8 AIR ADMITTANCE VALVE DETAIL
10 DISHWASHER DRAIN CONNECTION DETAIL 11 WATER HAMMER ARRESTOR DETAIL9ELECTRIC WATER HEATER DETAIL
LAVATORY OR SINK
ASSEMBLY
3/4" CONDENSATE
DRAIN IN WALL
SLIP-JOINT
FITTING
MIN. 1-1/2"
P-TRAP ASSEMBLY
FINISHED
FLOOR
ESCUTCHEON
PLATE
WALL
3/4" TYPE "M" COPPER TUBING,
SLOPED AT 1/4" PER FOOT
CLEAR AREA
FOR HANDICAP
9"27" MIN.29" MIN.WALLCURBSTRAINER
FINISHED FLOOR
CLAMP PAN TIGHTLY
INTO DRAIN COLLAR
SHOWER PAN
DRAIN BODY POURED IN PLACE
RECESSED 1/2" BELOW ROUGH SLAB
SURFACE
FLOOR ASSEMBLY;
RE:ARCH
OPTIONAL FUNNELSECURE TO GRATE
FLOOR
FINISHED FLOOR
ADJUSTABLE HOUSING
REMOVABLE STRAINER
COLLAR
TRIP LEVER
OVERFLOW AND DISCHARGE
INTO FIXTURE SIDE OR TRAP
POP-UP WASTE
1-1/2" WASTE & OVERFLOW
FITTING
• MIN. 1-1/2" P-TRAP ASSEMBLY IF
TRAP ARM IS 3'-6" OR LESS.
• MIN. 2" P-TRAP ASSEMBLY IF TRAP
ARM ASSEMBLY IS MORE THAN
3'-6".
12" DIAMETER FUNNEL
DRAIN LINE; SIZED
PER PLANS
APPROVED AIR GAP; 1" GAP
WHEN CONNECTED TO
SEWER WITH TRAP AND
VENT, 1-1/2" GAP FOR F.S.
OR OPEN SITE
3/4"SHUT-OFF
VALVE W/ PLUG
REDUCER FITTING
'Y-TYPE' STRAINER
INCOMING
DOMESTIC
WATER SUPPLY;
SIZED PER
PLANS
BACKFLOW
PREVENTOR
LINE SIZED
ISOLATION BALL
VALVES
ANCHORS FOR RISERS
PIPE RISER
RISER CLAMP (TYP)
BOLT (TYP)
PIPE SLEEVE
DIMENSION "A"
(SEE SCHEDULE)
FLOOR
SLAB
PIPE
BOLT BOLT
RISER
CLAMPS
PLAN VIEW
ELEVATION
1/2" THRU 1" 3/8" 1 1/4" X 3/16"
BOLT
DIA.
PIPE
SIZE
RISER CLAMP
DIMENSIONS
A X B
1 1/4" THRU 3" 3/8" 1 1/4" X 1/4"
4" 1/2" 1 1/2" X 1/4"
5" AND 6" 1/2" 2" X 1/4"
8" 5/8" 2" X 3/8"
10" 5/8" 2" X 1/2"
DIMENSION "B" (SEE SCHEDULE)
PIPE RISER
WALL
5/8"ø x 4" LONG
SLEEVE ANCHOR
BOLTS WITH
WASHERS
SPECIFIED PIPE CLAMP
45°
4" x 4" x 1/4" ANGLE BETWEEN
BRACKETS - WELDED TO
BRACKET
4" x 4" x 1/4" ANGLE BRACKET. BRACKETS AT END
AND BETWEEN EVERY TWO PIPE. MITER AND
WELD CORNERS. FOR 12" AND LARGER PIPE,
INSTALL BRACKET BETWEEN EACH PIPE.
NOTE: VERTICAL SPACING PER INTERNATIONAL MECHANICAL CODE
AS REQUIRED
CONCRETE SLAB, RE: STRUCTURAL, TO BE
POURED AFTER PIPE SUPPORTS ARE IN
PLACE STAINLESS STEEL TAB TO
BE CAST IN-PLACE WITH
SLAB
STAINLESS STEEL
ALL-THREAD AND
ACCESSORIES
VOID FORM, RE:
STRUCTURAL
PLYWOOD, PLACED
BY MECHANICAL
CONTRACTOR
SUPPORT PIPING FROM
PLYWOOD PRIOR TO
PLACEMENT OF
VOIDFORM AND
CONCRETE FLOOR
SLAB
PIPE HANGARS BELOW
GRADE TO BE
STAINLESS STEEL
BELOW GRADE PIPING
EARTH
FLOOR
GRADE
NOTE:
CONTRACTOR TO VERIFY WITH GEOTECH REPORT
IF VOID FORM SLAB IS NECCESARY PRIOR TO
INSTALLATION
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P502
PLUMBING
DETAILS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
5 CONDENSATE AT LAVATORY DETAIL 6 SHOWER DRAIN DETAIL 7 FLOOR DRAIN DETAIL
3 BATHTUB WASTE & OVERFLOW DETAIL2
BACKFLOW PREVENTOR W/ FUNNEL DRAIN
DETAIL
8 RISER ANCHOR DETAIL
4 PIPE RISER SUPPORT1VOID FORM SLAB PIPING SUPPORT DETAIL
2" REDUCED PRESSURE
BACKFLOW PREVENTOR
UNION, TYPICAL
2"CW
PRESSURE GAUGE WITH
ISOLATION VALVE, TYPICAL
2" DRAIN VALVE WITH
2" DRAIN PIPED TO
FLOOR DRAIN
MAIN WATER
SHUT OFF VALVE
4" COMBO
DOMESTIC/FIRE
ENTRY
STRAINER WITH BLOW DOWN
VALVE AND PIPING TO FLOOR
DRAIN/SINK, TYPICAL
2"CW TO WATER DOMESTIC
BOOSTER PUMP AND
BUILDING FIXTURES
2" DRAIN VALVE WITH 2"
DRAIN PIPED TO FLOOR
DRAIN
12" DIAMETER FUNNEL DRAIN,
ROUTE TO FLOOR DRAIN/SINK,
PROVIDE 2" AIR GAP, PROVIDE
PIPING SUPPORT FROM WALL
AND OR FLOOR, TYP.
M
2" DOMESTIC WATER
METER ASSEMBLY
4" FIRE SERVICE TO FIRE
BACKFLOW; RE: FPC SHOP
DRAWINGS
4" FIRE
FS
FS
FS
SEE FPC SHOP
DRAWINGS FOR SIZING
AND LAYOUT OF FIRE
SPRINKLER ZONES
WATER FLOW SWITCH
WITH WIRING TO
EXTERIOR AND INTERIOR
ALARMS (RE:
ELECTRICAL)
U.L. BUTTERFLY VALVE
WITH TAMPER FOR
ISOLATION OF
BACKFLOW PREVENTOR
6" U.L. APPROVED
DOUBLE CHECK
BACKFLOW PREVENTOR
ASSEMBLY, PROVIDE
WITH TAMPER SWITCH
ON EACH OS&Y GATE
VALVE (RE: ELECTRICAL)
PRESSURE GAUGE WITH
ISOLATION VALVE
U.L. BUTTERFLY VALVE
WITH TAMPER SWITCH
(RE: ELECTRICAL)
4" U.L. CHECK VALVE
WITH AUTO-BALL DRIP
TO FIRE DEPARTMENT
CONNECTION
2" DRAIN VALVE
EXTEND 2" DRAIN
THRU EXTERIOR
WALL AND
TERMINATE WITH 45°
ELBOW
NOTE:
FIRE ENTRY SHOWN FOR
CONFORMANCE ONLY. REFER TO FIRE
PROTECTION DRAWINGS
4" FIRE SERVICE FROM
COMBO DOMESTIC /FIRE
ENTRY
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P503
PLUMBING
DETAILS
SD
KL
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
2
WATER SOFTENING SYSTEM DETAIL REMOVED
2 VE CHANGES 03/03/23
1 DOMESTIC CW ENTRY DETAIL
2 FIRE ENTRY DETAIL
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
P601
PLUMBING
SCHEDULES
Checker
Author
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
PLUMBING FIXTURE SCHEDULE
PLAN
CODE DESCRIPTION
FIXTURE BASIS OF DESIGN ACCESSORIES
REMARKS
FLOW
GPF/GPM ADA WASTE VENT CW HWMANUFACTURER MODEL COMPONENT MANUFACTURER
BT-1 BATH TUB KOHLER K-715 VALVE / HAND
SHOWER
BY
CONTRACTOR
60"x30-1/4"x14" CAST IRON, DROP IN WIHT SIDE APRON, PROVIDE WITH
STAINLESS STEEL DRAIN. ROUGH BRASS SHOWER VALVE WITH CHROME TRIM,
TUB FAUCET, SHOWER HEAD, ARM. PROVIDE WITH DIVERTER VALVE, 36" SLIDE
BAR, HAND SHOWER AND HOSE.
1.5 YES 2" 1-1/2" 1/2" 1/2"
L-1 LAVATORY KOHLER K-20000 FAUCET BY
CONTRACTOR
RECTANGULAR BOWL, UNDERMOUNT, WALL OR COUNTER MOUNT FAUCET.
PROVIDE GRID DRAIN, 17 GAUGE P-TRAP, ANGLE SUPPLIES W/L.K. STOPS.
0.5 YES 2" 1-1/2" 1/2" 1/2"
S-1 SINK KOHLER K-80084-1PC FAUCET BY
CONTRACTOR
33"x22"x9-1/2" DEEP, SINGLE COMP., UNDERMOUNT, 18 GAUGE S.S.,
SINGLE-HOLE PUNCH. MANUALLY OPERATED CENTER-SET SINGLE HANDLE
FAUCET. PROVIDE GRID DRAIN, 17 GAUGE P-TRAP, ANGLE SUPPLIES W/L.K.
STOPS.
1.5 YES 2" 1-1/2" 1/2" 1/2"
SH-1 SHOWER VALVE DELTA T13H132 - - ROUGH BRASS SHOWER VALVE WITH CHROME TRIM, SHOWER HEAD, ARM.
PROVIDE WITH 2" DRAIN AND CHROME STRAINER, REFER TO ARCHITECTURAL
FOR BASIN, ENCLOSURE.
1.5 YES - - - 1/2"
WC-1 WATER CLOSET KOHLER K-25077 SEAT KOHLER K-4
650-A
FLOOR MOUNTED, TANK TYPE, ELONGATED RIM, OPEN FRONT SOLID PLASTIC
SEAT W/ ANTIMICROBIAL FINISH. PROVIDE ANGLE SUPPLY W/ L.K. STOPS
1.28 YES 3" 2" 1/2" -
PLUMBING ACCESSORY SCHEDULE
PLAN
CODE DESCRIPTION MANUFACTURER MODEL REMARKS WASTE VENT CW HW
4"FCO FLOOR CLEANOUT JOSAM 57000-Z COATED CAST IRON WITH LEVEL ADJUSTMENT, INTERNAL GASKET, NO-HUB BOTTOM OUTLET, SCORIATED SPECIAL
DUTY NICKALOY COVER, COORDINATE MODEL SERIES WITH FLOOR TYPE.
4" - - -
DCBP-1 REDUCED PRESSURE
BACKFLOW PREVENTER
AMES C200-OSY TYPE 304 STAINLESS STEEL BODY, SLEEVE ACCESS PORT, OS&Y VALVES, PROVIDE WITH TAMPER SWITCHES. - - 4"
DGCO GRADE CLEANOUT JOSAM 58460A COATED CAST IRON WITH FLANGE, BOTTOM CONNECTION, INTERNAL COUNTERSUNK PLUG AND SCORIATED ROUND
TOP.
6" - - -
FD-1 FLOOR DRAIN JOSAM 30000-A TWO-PIECE STRAINER WITH DOUBLE FLANGE, CLAMP RING, ROUND ADJUSTABLE NIKALOY STRAINER. 2" 1-1/2" - -
FS-1 FLOOR SINK PROFLO PF906P SQUARE CAST IRON BODY, ACID RESISTANT INTERIOR, NO-HUB BOTTOM OUTLET, INTERNAL ALUMINUM DOME
STRAINER AND CAST IRON, ACID RESISTANT ANTI-TILTING NON-TRAFFIC GRATE.
4" 2" - -
GDU-1 GARBAGE DISPOSAL UNIT IN-SINK-ERATOR BADGER 5 GALVANIZED STEEL CONSTRUCTION, CONTINUOUS FEED, WITH W ALL OUTLET. 1/2 H.P., 120/60/1Ø. COORDINATE
WITH ELECTRICAL CONTRACTOR FOR CONTROL SWITCH LOCATION AND ROUTING.
2" - - -
HT-1 HYDROCUMULATOR TANK WESSELS FXA-85 90 GALLON CAPACITY, ASME RATED BLADDER TYPE EXPANSION TANK, STEEL SHELL WITH NPT EPOXY LINER,
PROVIDE WITH DOMESTIC BOOSTER PUMP SYSTEM..
- - 1-1/4" -
IMB-1 ICE MAKER BOX SIOUX CHIEF 696-GR1010 UL 1479 FIRE RATED OUTLET BOX WITH 1/4 TURN VALVE AND INTEGRAL HAMMER ARRESTOR, PAINT FACEPLATE TO
MATCH (RE: ARCH).
- - 1/2" -
RPBP-1 REDUCED PRESSURE
BACKFLOW PREVENTER
WATTS LF909M1-QT-S BRONZE BODIED VALVE WITH STAINLESS STEEL CHECK ASSEMBLIES, WITH 1/4 TURN BALL VALVES, PROVIDE WITH
STRAINER AND FUNNEL DRAIN. 76 GPM AT 10 PSI LOSS MAX.
- - 2" -
TEA-1 THERMAL EXPANSION
ABSORBER
PROFLO PFXT-5I 2.1 GALLON CAPACITY, DIAPHRAM TYPE, NSF-61 RATED.- - 3/4" -
TMV-1 THERMOSTATIC MIXING
VALVE
ZURN ZW1017XL 0.5 GPM MIN. FLOW, 10 PSI PRESSURE DROP AT 9 GPM MAX., TRANSITION TO INLET AND OUTLET SIZES AS
REQUIRED, MOUNT ON WALL WITH ACCESS FOR SERVICE AND ADJUSTMENT; SET TO 120 DEG. F.
1" 1"
WB-1 WASHER BOX SIOUX CHIEF 696-RG2313 UL 1479 FIRE RATED OUTLET BOX WITH 1/4 TURN VALVE AND INTEGRAL HAMMER ARRESTOR, PAINT FACEPLATE TO
MATCH (RE: ARCH).
2" 1-1/2" 1/2" 1/2"
WH-1 WALL HYDRANT WOODFORD MODEL B67 RECESSED HOSE BOX WITH WALL FLANGE, LOCKABLE DOOR WITH KEY, REMOVABLE KEY HANDLE, VACUUM
BREAKER, COORDINATE ROD DEPTH WITH WALL THICKNESS.
- - 3/4" -
PLUMBING PUMP SCHEDULE
PLAN
CODE MANUFACTURER & MODEL LOCATION SERVES TYPE GPM
HEAD
(FT.)
MOTOR/ELECTRICAL VIBRATION
ISOLATION CONTROL
WEIGHT
(LBS)NOTESRPM HP VOLTS PHASE FLA
DCP-1 GRUNDFOS MAGNA 32-60 DWELLING UNITS DOMESTIC HW INLINE 0.5 18 36003 1/6 115 1 1.4 REQUIRED NOTE 3 13 3,4
DBP-1 WEIL 5121-030-05-030 WATER ENTRY DOMESTIC CW DUPLEX 56
(TOTAL GPM)
127 3500 3 (EA.) 208 3 20.2 - NOTE 4 371 3-6
1. 24-HOUR TIME CLOCK, ADJUSTABLE BY OWNER, PROVIDE WITH AQUASTAT SET TO 7°F LESS THAN TMV-1 OUTPUT.
2. PROVIDE TEST AND BALANCING REPORT FOR DOMESTIC HOT WATER RECIRCULATION LOOP.
3. PACKAGED DUPLEX BOOSTER SYSTEM DESIGNED FOR 67% REDUNDANCY (56 GPM TOTAL FLOW).
4. VARIABLE FREQUENCY DRIVES WITH LEAD/LAG ALTERNATION, INTEGRAL TOUCH SCREEN CONTROLS AND MULTI-LEVEL ACCESS.
5. FLANGED CONNECTIONS, PUMPS OF STAINLESS STEEL CONSTRUCTION.
6. PROVIDE WITH REMOTE MOUNT 90 GALLON HYDROCUMULATOR TANK, HT-1.
ELECTRIC WATER HEATER SCHEDULE
PLAN
CODE MANUFACTURER & MODEL SERVES
GPH RECOVERY
@ 100°F RISE CAPACITY (GAL)
EFFICIENCY
(UEF)
HEATING
CAPACITY (KW)VOLTAGE PHASE
DIMENSIONS WEIGHT
(LBS)NOTESHEIGHT WIDTH DEPTH
EWH-1 STATE WATER HEATERS
EN6-30-DORTW
DOMESTIC HOT WATER 21 30 0.89 4.0 208 1 46-1/2" 19" 19" 95 SEE NOTES
EWH-2 STATE WATER HEATERS
EN6-40-DORT
DOMESTIC HOT WATER 21 40 0.92 6.0 208 1 61-1/4" 18" 18" 118 SEE NOTES
1. PROVIDE WITH T&P RELIEF VALVE AND DRAIN PAN PIPED TO ADJACENT FLOOR DRAIN THRU APPROVED AIR GAP.
2. PROVIDE VACUUM BREAKER ON CW INLET, LOCATED ABOVE TOP OF UNIT.
2
2 VE CHANGES 03/03/23