HomeMy WebLinkAbout21234_Haymeadow_BLDG G_PERMIT RESUBMITTAL_ELEC_2023-03-03_StampedABBREVIATIONS
DUPLEX RECEPTACLE, MOUNTED +18" O.C. UNO
AC = MOUNTED +8" O.C. ABOVE COUNTER EWC = GFI RECEPTACLE FOR WATER COOLER
GFI = GROUND FAULT CIRCUIT INTERRUPTER T = TAMPER RESISTANT PER NEC 406.12(A)
WP = GFCI WITH WEATHERPROOF IN-USE COVER PER NEC 406.9(B)(1)
DUPLEX RECEPTACLE LISTED FOR USE IN COUNTERTOPS, PROTECTED BY UPSTREAM GFCI
DUPLEX RECEPTACLE, FLUSH MOUNTED IN FLOOR BOX
QUADRUPLEX RECEPTACLE, MOUNTED +18" O.C. UNO
AC = MOUNTED +8" O.C. ABOVE COUNTER GFCI = GROUND FAULT CIRCUIT INTERRUPTER
T = TAMPER RESISTANT PER NEC 406.12 WP = GFCI WITH WEATHERPROOF IN-USE COVER
QUADRUPLEX RECEPTACLE, FLUSH MOUNTED IN FLOOR BOX
SPECIAL RECEPTACLE, COORDINATE INSTALLATION WITH EQUIPMENT SUPPLIED
ED = ELECTRIC DRYER, PROVIDE 208V/1, 30A-2P 4-WIRE CONNECTION.
ER = ELECTRIC RANGE, PROVIDE 208V/1, 50A-2P 4-WIRE CONNECTION.
COUNTER-MOUNTED AIR SWITCH FOR GARBAGE DISPOSAL. COORDINATE WITH MILLWORK VENDOR.
MOTOR CONNECTION, COORDINATE INSTALLATION WITH EQUIPMENT SUPPLIED
G = GARAGE DOOR MOTOR ASSEMBLY WITH INTEGRAL LIGHTING COMPONENT
JUNCTION BOX SIZE PER NEC 314, PROVIDE COVER PLATE TO CONCEAL WIRING WITHIN
PANELBOARD
ELECTRICAL BRANCH CIRCUIT -PROTECTED PER NEC 240.4(D) REQUIREMENTS
DISCONNECT SWITCH (F = FUSIBLE)
UTILITY COMPANY METER
ELECTRICAL SYMBOL LIST
A AMP
AC ABOVE COUNTER
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFI ARC FAULT INTERRUPTER
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
AIC AMPS INTERRUPTING CAPACITY
AL ALUMINUM
AWG AMERICAN WIRE GAUGE
AV AUDIO/VISUAL
BLDG BUILDING
C CONDUIT
CATV CABLE TELEVISION SYSTEM
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CL CENTERLINE
CU COPPER
DWG DRAWING
(E)EXISTING
EF EXHAUST FAN
EMT ELECTRIC METALLIC TUBING
EM EMERGENCY
EPO EMERGENCY POWER OFF
FLA FULL LOAD AMPS
GD GARBAGE DISPOSAL
GR GROUND
GC GENERAL CONTRACTOR
GFI/GFCI GROUND FAULT CIRCUIT INTERRUPTER
HACR HACR (HEATING, AC & REFRIGERATION) RATED
HP HORSE POWER
IG ISOLATED GROUND
IP INTERNET PROTOCOL
JB JUNCTION BOX
KCMIL 1000 CIRCULAR MILS
KV KILOVOLT
KVA KILOVOLT AMPERES
KW KILOWATT
KWH KILOWATT HOUR
LAN LOCAL AREA NETWORK
LCP LIGHTING CONTROL PANEL
LRA LOCKED ROTOR AMPS
LSIGA L(LONG)
S (SHORT)
I (INSTANTANEOUS)
G (GROUND FAULT)
A (ARC ENERGY REDUCTION)
LTFC LIQUID TIGHT FLEXIBLE CONDUIT
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MLO MAIN LUG ONLY
MSB MAIN SWITCH BOARD
(N)NEW
N.C.NORMALLY CLOSED
N.O.NORMALLY OPEN
NF NON-FUSED
NL NIGHT LIGHT
NIC NOT IN CONTRACT
P POLE
PC PLUMBING CONTRACTOR
PH PHASE
PPE PERSONAL PROTECTION EQUIPMENT
PVC POLYVINYL CHLORIDE CONDUIT
QTY QUANTITY
RCP REFLECTED CEILING PLAN
RLA RUNNING LOAD AMPS
RMC RIGID METAL CONDUIT
RNC RIGID NON-METALLIC CONDUIT
SPDT SINGLE POLE, DOUBLE THROW
SPST SINGLE POLE, SINGLE THROW
ST SHUNT TRIP
TL TWISTLOCK
TR TAMPER RESISTANT
TYP TYPICAL
UL UNDERWRITERS LABORATORIES, INC.
UNO UNLESS NOTED OTHERWISE
USP UNINTERRUPTIBLE POWER SUPPLY
V VOLT
W WIRE
WP WEATHER PROOF
WPI WEATHER PROTECTED IN-USE
XFMR TRANSFORMER
XP EXPOSION PROOF
LABELING REQUIREMENTS
ALL ELECTRICAL LABELS SHALL COMPLY WITH LATEST NATIONAL ELECTRICAL CODE REQUIREMENTS.
GENERAL LABELING REQUIREMENTS NOTED BELOW MAY NOT BE COMPLETE OR COVER ALL INSTALLATIONS.
WIRING DEVICES:
PANEL NAME -CIRCUIT NAME
PROVIDE BLACK LETTERING ON CLEAR LABEL FOR NORMAL CIRCUITS AND RED LETTERING ON CLEAR LABEL
FOR EMERGENCY/STANDBY CIRCUITS.
STARTERS / DISCONNECTS / VFDs:
EQUIPMENT ID
VOLTAGE / PHASE / WIRES
INDICATE FUSE SIZE, IF APPLICABLE
FED FROM CIRCUIT NAME
FEEDING TO CIRCUIT NAME
ARC FLASH LABELS PER NFPA-70E & NEC INDICATING:
1. DANGER OR WARNING HEADER
2. INCIDENT ENERGY
3. MINIMUM ARC RATING
4. ARC FLASH BOUNDARY
5. PERSONAL PROTECTIVE EQUIPMENT (PPE)
6. LIMITED APPROACH
7. RESTRICTED APPROACH
8. SHOCK RISK
9. DATE LABEL WAS APPLIED
SWITCHBOARDS, TRANSFORMERS, HARMONIC FILTERS, ELECTRICAL PANELS:
EQUIPMENT NAME
EQUIPMENT RATING
FED FROM XXXX
VOLTAGE / PHASE / AMPS
PRIMARY DISCONNECT LOCATION AND NAME, WHERE APPLICABLE
COLORED -CONDUITS AND JUNCTION BOX REQUIREMENTS:
RED-COLORED -FIRE ALARM
BLUE-COLORED -TEMPERATURE CONTROLS
MAXIMUM AVAILABLE FAULT CURRENT:
SERVICE EQUIPMENT SHALL BE LEGIBLY MARKED IN THE FIELD WITH THE MAXIMUM AVAILABLE FAULT
CURRENT. THE FIELD MARKING SHALL INCLUDE THE DATE. THE FAULT CURRENT CALCULATION WAS
PERFORMED AND BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED.
POWER
M
F
J
LIGHTING
ROUND LUMINAIRE (HALF SHADE = UNSWITCHED) -REFER TO LUMINAIRE SCHEDULE
ROUND EMERGENCY DOWNLIGHT -REFER TO LUMINAIRE SCHEDULE
WALL MOUNTED LUMINAIRE -REFER TO LUMINAIRE SCHEDULE
TRACK LIGHTING (# OF HEADS SHOWN) -REFER TO LUMINAIRE SCHEDULE
LINEAR FLUORESCENT LUMINAIRE -REFER TO LUMINAIRE SCHEDULE
LINEAR FLUORESCENT EMERGENCY LUMINAIRE -REFER TO LUMINAIRE SCHEDULE
EXIT SIGN -CEILING MOUNTED (SHADE = FACE, ARROW = DIRECTION), CONNECT AHEAD OF LIGHT
SWITCH -REFER TO LUMINAIRE SCHEDULE
EXIT SIGN -BACK MOUNTED (SHADE = FACE, ARROW = DIRECTION), CONNECT AHEAD OF LIGHT
SWITCH -REFER TO LUMINAIRE SCHEDULE
POLE MOUNTED LUMINAIRE (CIRCLE INDICATES POLE, BOXES INDICATE HEADS) -REFER TO
LUMINAIRE SCHEDULE
TOGGLE SWITCH, MOUNTED +48" O.C. UNO
2 = TWO POLE 3 = THREE WAY
4 = FOUR WAY D = DIMMER (SIZED TO MATCH LOAD SERVED)
K = KEYED SWITCH M = MOMENTARY CONTACT SWITCH
OC = OCC. SENSOR SWITCH DR = DOOR ACTIVATED
P = SWITCH WITH PILOT LIGHT T = TIMER
LV = LOW VOLTAGE CB = CIRCUIT BREAKER
OCCUPANCY SENSOR -CEILING MOUNTED, DUAL TECHNOLOGY
COMMUNICATIONS
DUPLEX DATA RECEPTACLE, MOUNTED +18" O.C. UNO AC = MOUNTED +8" O.C. ABOVE COUNTER
DUPLEX DATA RECEPTACLE, FLUSH MOUNTED IN FLOOR BOX
SIMPLEX TELEPHONE RECEPTACLE, MOUNTED +18" O.C. UNO
AC = MOUNTED +8" O.C. ABOVE COUNTER
W = MOUNTED +54" O.C. ABOVE FINISHED FLOOR FOR WALL MOUNTING PHONE
COMBINATION TEL/DATA RECEPTACLE, FLUSH MOUNTED IN FLOOR BOX --
PROVIDE (1) DATA AND (1) TELEPHONE JACK UNO
CABLE TELEVISION OUTLET, COORDINATE MOUNTING HEIGHT WITH OWNER
CATV OUTLET. PROVIDE BACKBOX, COAX/CAT 5 CABLE, DEVICE JACK AS DIRECTED BY OWNERS
AUTHORIZED REPRESENTATIVE. REFER TO PLANS FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
OS
TV
SHEET LIST
FIRE ALARM SYSTEM
1. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE.
2. CONTRACTOR SHALL ENSURE THAT ALL MOUNTING HEIGHTS COMPLY WITH CURRENT ADA REQUIREMENTS.
3. WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING
LINE OR +12" ABOVE TOP OF DOOR TRIM WHERE DISTANCE TO CEILING IS GREATER THAN 24".
4. ALL ABOVE COUNTER (DESIGNATED BY "AC") SHALL BE MOUNTED 8" ABOVE COUNTER OR MAXIMUM HEIGHT OF 44" TO TOP OF DEVICE.
VERIFY HEIGHTS WITH ARCHITECT.
5. FOR CEILINGS BELOW 7'-4", FIRE ALARM STROBE OR HORN/STROBES SHALL BE WALL MOUNTED 6" BELOW FINISHED CEILING.
6. IN LOCATIONS WHERE SIMILAR DEVICES ARE MOUNTED AT THE SAME HEIGHT, DEVICES SHALL BE PROPERLY "GANGED" AND SHALL
HAVE A SINGLE COVERPLATE.
7. IN LOCATIONS WHERE DIFFERENT DEVICES ARE MOUNTED AT DIFFERENT HEIGHTS WITHIN FOUR FEET OF ONE ANOTHER, DEVICES
SHALL BE MOUNTED SUCH THAT THEY HAVE A COMMON CENTERLINE. IF THERE ARE THREE OR MORE DEVICES, THE CONTRACTOR
SHALL REQUEST A DETAIL FROM THE ARCHITECT.
NOTES:
FINISHED FLOOR18"RECEPTACLEDISCONNECT SWITCHTHE CENTER OF THE OPERATING HANDLE OF THE
SWITCH OR CIRCUIT BREAKER CANNOT BE MORE
THAN 6'-7" ABOVE THE FLOOR OR PLATFORM
WHEN IT IS IN ITS HIGHEST POSITIONPANELBOARDEQUIPMENT POWER FEEDVARIESJ
DEVICE MOUNTING REQUIREMENTS
FINISHED FLOOREXTERIOR LIGHTDOOR 12"DOOR 12"EXIT
48"MANUAL WALL MOUNTED LIGHTING CONTROLSFINISHED FLOORDOOR CONTACTDOOR
VARIESFIRE ALARM DEVICESCOORDINATED W/ ACCESS CONTROLVENDOR18"DATA OUTLETH
MOUNTING REQUIREMENTS MUST BE
COORDINATED WITH FIRE ALARM DESIGNER
F
S
S
S
UL LISTED COMBINATION CARBON MONOXIDE/SMOKE ALARM PER IFC 908.7.4.1-PROVIDE
HARDWIRED 120V POWER AND BACK-UP BATTERY POWER. WHERE MORE THAN ONE ALARM IS
LOCATED IN A SINGLE DWELLING UNIT, LINK OPERATION IN ACCORDANCE WITH 101-9.6.2.9.3.
PROVIDE SYSTEM DETECTORS FOR NON-DWELLING UNIT AREA PROTECTION PER LIFE SAFETY
SYSTEM DESIGN BY OTHERS -REFER TO GENERAL NOTE 24 THIS SHEET.
FIRE ALARM - HORN
FIRE ALARM - STROBE
FIRE ALARM - HORN AND STROBE
FIRE ALARM CONTROL PANEL
FIRE ALARM REMOTE ANNUNCIATOR PANEL
REMOTE TEST STATION
FACP
FAA
RTS
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E000
ELECTRICAL
LEGEND & NOTES
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
G3/3/2023
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E101
ELECTRICAL SITE
PLAN
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
G3/3/2023
'HP'
EM
EM
X2
TYP.
TYP.
HP-1
HP-1
HP-1
HP-1
HP-3
LEVEL 2,3
HP-1
TYP.
HP-7HP-11HP-11
HP-13
H1
LCP
HP-13
TYP.
HP-2,4,6
HP-1 H1
HP-5 H1 HP-5 H1
HP-7
H1
HP-7 H1
HP-7 H1
HP-7 H1
HP-11
2
5
4
3
3
4
1
EUH-1 EUH-1
HP-22,24
H1
HP-7 H1
GFI
HP-11STORAGE
162
STORAGE
161
STORAGE
160
STORAGE
163
STORAGE
164
STORAGE
165
STORAGE
166
SOLAR INVERTER
169
STORAGE
170
STORAGE
168
MECHANICAL
ROOM
167
H1 H1
HP-1
H1
DBP-1
HP-5 H1HP-5 H1HP-5 H1HP-5 H1
HP-5 H1
H1
HP-13
GFI
GFI
HP-30,32
EUH-3
EUH-1
OC
OCOCOCOCOCOCOCOC
OC
HP-14,16
HP-18,20
HP-26,28
6
OC
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E201
ELECTRICAL
LEVEL 1.1
LAYOUT
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 ELECTRICAL FLOOR PLAN - LEVEL 1.1
XKEYED NOTES:
PROVIDE LIGHTING CONTROL PANEL OR LIGHTING RELAY PANEL AND 7-
DAY PROGRAMMABLE ASTRONOMICAL TIMECLOCK FOR THE CONTROL OF
THE HOUSE LIGHTING FIXTURES.
PROPOSED LOCATION OF HOUSE EQUIPMENT PANEL.
CONNECT EXIT SIGNS AND EMERGENCY LIGHTING UNITS TO DESIGNATED
CIRCUIT, AHEAD OF ALL CONTROLS.
PROVIDE LIGHT FIXTURE, TYPE AS INDICATED. SEE HOUSE LIGHT FIXTURE
SCHEDULE.
CONTINUE TO DEVICES ON SAME CIRCUIT.
ROUTE 1-1/4" SPARE CONDUIT FROM EACH OF (11) UNIT PANELS TO
INVERTER ROOM AND ROUTE (11) 1-1/4" CONDUITS FROM INVERTER ROOM
VERTICALLY TO ROOF FOR FUTURE TIE IN TO PV SYSTEM. PROVIDE PULL
STRINGS AND CAP OPEN ENDS OF CONDUIT. REFER TO ONE-LINE AND
PANEL SCHEDULES FOR ADDITIONAL INFORMATION.
1.
2.
3.
4.
5.
6.
NORTH
1
2
2
1 ABCO COMMENTS 02/02/2023
2 VE CHANGES 03/03/23G3/3/2023
G1 G2 G3 G4 G5 G6
X2
G1-1 G2-1 G3-1 G4-1 G5-1 G6-1
G1-3 G2-3 G3-3
G4-3 G5-3 G6-3
G1-5 G2-5 G3-5 G4-5 G5-5 G6-5
TYP.
MDP
HP-2,4,6
HP-3
HP-3
HP-3
HP-21
TYP.
G1-6,8 G2-6,8 G3-6,8 G4-6,8 G5-6,8 G6-6,8
GFI
WP
HP-30,32
GFI
WP
HP-21
H7 HP-12H7HP-12
G1-2,4 G2-2,4 G3-2,4 G4-2,4 G5-2,4 G6-2,4
HP-12H1
EUH-2 EUH-2 EUH-2 EUH-2 EUH-2 EUH-2
1
4
6
5
3 3 3 3 3 3
4 4 4 4 4
H1
H1
EUH-3
2 TYP.
HP-3
H7
HP-3
H7
FACP
HP-15
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E202
ELECTRICAL
LEVEL 1.2
LAYOUT
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
XKEYED NOTES:
PROPOSED LOCATION OF BUILDING MAIN DISTRIBUTION BOARD.
CONNECT EXIT SIGNS AND EMERGENCY LIGHTING UNITS TO DESIGNATED
CIRCUIT, AHEAD OF ALL CONTROLS.
PROPOSED LOCATON OF GARAGE PANEL.
EV CHARGER READY LOCATION TO BE FIELD COORDINATED WITH
ARCHITECT AND OWNER. PROVIDE 1"C (3) #8 + #10GND TO PANEL G*.
PROVIDE RECEPTACLE FOR POWERED GARAGE DOOR OPENER.
PROVIDE LIGHT FIXTURE, TYPE AS INDICATED. SEE HOUSE LIGHT FIXTURE
SCHEDULE.
1.
2.
3.
4.
5.
6.
1/4" = 1'-0"1 ELECTRICAL FLOOR PLAN - LEVEL 1.2
NORTH
1
2
1 ABCO COMMENTS 02/02/2023
2 VE CHANGES 03/03/23G3/3/2023
HP-3
HP-1
HP-17
1
2
3
TYP.
TYP.
HP-1 H1
H1
EM
HP-3
EM
HP-3
TYP.
HP-3
H7
X2
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E203
ELECTRICAL
LEVEL 2.1
LAYOUT
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
XKEYED NOTES:
PROVIDE LIGHT FIXTURE, TYPE AS INDICATED. SEE HOUSE LIGHT FIXTURE
SCHEDULE.
CONTINUE TO DEVICES ON SAME CIRCUIT.
CONNECT EXIT SIGNS AND EMERGENCY LIGHTING UNITS TO DESIGNATED
CIRCUIT, AHEAD OF ALL CONTROLS.
1.
2.
3.
1/4" = 1'-0"1 ELECTRICAL FLOOR PLAN - LEVEL 2.1
NORTH
1
2
1 ABCO COMMENTS 02/02/2023
2 VE CHANGES 03/03/23G3/3/2023
H1 1 TYP.HP-1
HP-17
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E204
ELECTRICAL
LEVEL 2.2
LAYOUT
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
XKEYED NOTES:
PROVIDE LIGHT FIXTURE, TYPE AS INDICATED. SEE HOUSE LIGHT FIXTURE
SCHEDULE.
1.
1/4" = 1'-0"1 ELECTRICAL FLOOR PLAN - LEVEL 2.2
NORTH
1
2
1 ABCO COMMENTS 02/02/2023
2 VE CHANGES 03/03/23G3/3/2023
A
1 3
D
4 6
F
B
C
E
2 5
HP-3
HP-1
HP-1
1
2
TYP.
TYP.
3
HP-17
H1
X1
H1EM
HP-3
EM
HP-3
TYP.
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E205
ELECTRICAL
LEVEL 3.1
LAYOUT
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
XKEYED NOTES:
PROVIDE LIGHT FIXTURE, TYPE AS INDICATED. SEE HOUSE LIGHT FIXTURE
SCHEDULE.
CONTINUE TO DEVICES ON SAME CIRCUIT
CONNECT EXIT SIGNS AND EMERGENCY LIGHTING UNITS TO DESIGNATED
CIRCUIT, AHEAD OF ALL CONTROLS
1.
2.
3.
1/4" = 1'-0"1 ELECTRICAL FLOOR PLAN - LEVEL 3.1
NORTH
1
2
1 ABCO COMMENTS 02/02/2023
2 VE CHANGES 03/03/23G3/3/2023
HP-3 H1
1 TYP.
HP-3 H1
HP-17
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E206
ELECTRICAL
LEVEL 3.2
LAYOUT
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
XKEYED NOTES:
PROVIDE LIGHT FIXTURE, TYPE AS INDICATED. SEE HOUSE LIGHT FIXTURE
SCHEDULE.
1.
1/4" = 1'-0"1 ELECTRICAL FLOOR PLAN - LEVEL 3.2
NORTH
1
2
1 ABCO COMMENTS 02/02/2023
2 VE CHANGES 03/03/23G3/3/2023
TV
A A A
A
A A
A A
A
A
A
A
A
A
B
B
B
C
E
1
2
2
3
4 TYP.
5
6
7
9
10
11 TYP.
12
13 TYP.
14
15
S
16
S
17
18
20
21
21
D
19
TV
22 TYP.
EWH-1
VTAC-2
EF-1 30F
F
A A
A
A
A
A
A
A
A
AA
A
A
C
E
1223
4TYP.
5
6
72
9
10
11 TYP.
12
13 TYP.
14
S 16
S
17
18
20
21 21
EWH-1
19
15
22TYP.
TV
TV
VTAC-1
EF-1
23
30 F
F
21
F
F
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E401
ELECTRICAL UNIT
PLANS
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 ELECTRICAL UNIT PLAN - 2 BEDROOM TYPE 6
1/4" = 1'-0"2 ELECTRICAL UNIT PLAN - 1 BEDROOM TYPE 2
XKEYED NOTES:
PROVIDE DEDICATED 15A 120V BRANCH CIRCUIT AND OUTLET FOR
REFRIGERATOR. REFER TO DWELLING UNIT PANEL SCHEDULE FOR
ADDITIONAL INFORMATION AND REQUIREMENTS. LOCATE PER EQUIPMENT
MFR SPECIFICATIONS.
PROVIDE ABOVE-COUNTER DUPLEX GFCI RECEPTACLES FOR SMALL
APPLIANCES PER NEC 210.52(B)(3) AND 210.52(C) REQUIREMENTS.
INSTALLATION SHALL COMPLY WITH NEC 210.8(A) AND 210.12(A) TO THE
SATISFACTION OF THE INSPECTING AUTHORITY HAVING JURISDICTION.
PROVIDE 50A 250V 4-WIRE NEMA 14-50R RECEPTACLE FOR RANGE/OVEN
OR PER EQUIPMENT MFR SPECIFICATIONS AS DIRECTED BY OWNERS
AUTHORIZED REPRESENTATIVE. VERIFY EXACT LOCATION AND
REQUIREMENTS PRIOR TO ANY INSTALLATION.
REFER TO ARCHITECTURAL DRAWINGS AND DETAILS AND COORDINATE
WITH GENERAL CONTRACTOR FOR ALL LUMINAIRES. PROVIDE ALL
EQUIPMENT AS DIRECTED FOR A COMPLETE AND OPERABLE
INSTALLATION.
PROVIDE 30A 250V 4-WIRE NEMA 14-30R RECEPTACLE FOR DRYER UNIT OR
PER EQUIPMENT MFR SPECIFICATIONS. COORDINATE WITH OWNERS
EQUIPMENT VENDOR TO PROVIDE CONNECTION TO 65VA REMOTE IN-LINE
FAN AND CONNECT TO DRYER AS REQUIRED. RE: MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
PROVIDE EXTERIOR OUTLETS PER NEC 210.52(E)(2) & (3) REQUIREMENTS
TO THE SATISFACTION OF THE INSPECTING AUTHORITY HAVING
JURISDICTION.
PROVIDE BELOW-COUNTER SWITCHED RECEPTACLE FOR GARBAGE
DISPOSAL. PROVIDE DEDICATED BRANCH CIRCUIT AND SPST AIR SWITCH
CONTROLLER, FLUSH IN COUNTER. COORDINATE INSTALLATION AND
LOCATION OF ALL DEVICES IN MILLWORK WITH GENERAL CONTRACTOR
AND MILLWORK VENDOR PRIOR TO ANY INSTALLATION. PROVIDE CORD
AND PLUG IF NOT PROVIDED BY PLUMBING CONTRACTOR.
PROVIDE RECEPTACLE LISTED FOR USE IN COUNTERTOPS AS REQUIRED
PER NEC 210.52(C)(5) ADJACENT TO SINK. PROVIDE GFCI PROTECTION AS
REQUIRED. COORDINATE INSTALLATION WITH MILLWORK VENDOR AND
GENERAL CONTRACTOR PRIOR TO ANY INSTALLATION.
PROVIDE DEDICATED 20A GFCI BRANCH CIRCUIT FOR DISHWASHER.
LOCATE OUTLET UNDER SINK AND LABEL AS DISHWASHER. COORDINATE
INSTALLATION WITH PLUMBING CONTRACTOR AND LOCATION OF ALL
DEVICES IN MILLWORK PRIOR TO ANY INSTALLATION. PROVIDE GFCI
PROTECTION PER NEC 210.8(D).
PROVIDE DEDICATED 20A GFCI BRANCH CIRCUIT TO SERVE DWELLING
UNIT BATHROOMS PER NEC 210.11(C)(3), 210.8(A)(1) AND 210.52(D)
REQUIREMENTS. LOCATE AT SIDEWALL ADJACENT TO MIRROR TO SUIT
EACH CONDITION. DO NOT LOCATE IN MIRROR. VERIFY EXACT LOCATION
WITH ARCHITECT PRIOR TO ROUGH IN AND LOCATE AS DIRECTED.
PROVIDE GENERAL PURPOSE CONVENIENCE OUTLETS THROUGHOUT
DWELLING UNITS PER NEC 210.52 REQUIREMENTS, TYPICAL. VERIFY
EXACT LOCATION OF ALL DEVICES FOR SPECIAL EQUIPMENT SUCH AS
TV'S, ETC. PRIOR TO ROUGH IN AND LOCATE AS DIRECTED.
PROVIDE "MEDIA BOX" FOR LOW VOLTAGE SYSTEMS DISTRIBUTION WITHIN
DWELLING UNIT. PROVIDE ADDITIONAL 120V RECEPTACLE IF REQUIRED.
PROVIDE TELE/DATA CABLING THROUGHOUT DWELLING TO DEVICES AS
REQUIRED.
PROVIDE FAN-RATED CEILING BOX PER NEC 314.27(C). LOCATED AS
DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. PROVIDE 3-WIRE
CONNECTION FOR POSSIBLE FAN/CONTROL AS DIRECTED.
PROPOSED LOCATION OF DWELLING UNIT PANEL. COORDINATE EXACT
LOCATION WITH ARCHITECT AND GENERAL/MECHANICAL CONTRACTORS
PRIOR TO ANY INSTALLATION TO AVOID CONFLICTS WITH OTHER SYSTEMS.
FINAL LOCATION AND INSTALLATION SHALL PROVIDE ALL WORKING
CLEARANCES REQUIRED PER NEC 110.26 REQUIREMENTS. DO NOT
LOCATE PANEL IN CLOTHES CLOSET OR RESTROOMS.
PROVIDE 120V CONNECTION TO EXHAUST FAN. COORDINATE EXACT
REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ANY
INSTALLATION. PROVIDE ALL EQUIPMENT FOR A COMPLETE AND
OPERABLE INSTALLATION. PROVIDE SEPARATE CONTROL SW ITCH AS
DIRECTED BY OWNERS AUTHORIZED REPRESENTATIVE.
PROVIDE 120V CONNECTION AND INSTALL UL 217 SMOKE DETECTOR(S)
PER IBC 907.2.11.2 REQUIREMENTS. INTERCONNECT MULTIPLE ALARMS AS
REQUIRED PER IBC 907.2.11.5. INSTALLATION TO BE TO THE SATISFACTION
OF THE INSPECTING AUTHORITY HAVING JURISDICTION (IAHJ). PROVIDE
COMBINATION SMOKE/CO DETECTOR IF ACCEPTABLE TO IAHJ.
PROVIDE DEDICATED 20A 120V BRANCH CIRCUIT TO COMBO MICROWAVE /
RECIRC VENT, TYPICAL ALL NON-ADA UNITS. COORDINATE EXACT
LOCATION AND ALL EQUIPMENT REQUIREMENTS WITH MECHANICAL
CONTRACTOR PRIOR TO ANY INSTALLATION. PROVIDE ALL EQUIPMENT
FOR A COMPLETE AND OPERABLE INSTALLATION.
PROVIDE DEDICATED 20A 120V BRANCH CIRCUIT FOR LAUNDRY
EQUIPMENT PER NEC 210.11(C)(2) AND 210.52(F) REQUIREMENTS. VERIFY
EXACT LOCATION PRIOR TO ROUGH IN AND LOCATE AS DIRECTED.
VERIFY EXACT LOCATION AND REQUIREMENTS WITH MECHANICAL
CONTRACTOR PRIOR TO ANY INSTALLATION. REFER TO GENERAL NOTES
ABOVE FOR ADDITIONAL REQUIREMENTS. REFER TO EQUIPMENT
SCHEDULE FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
STUB OUT 1/2" CONDUIT ABOVE CEILING FROM ENTRY DOOR/FRAME
ASSEMBLY FOR ACCESS CONTROL/DOOR STRIKE (BY OTHERS).
UNDERCOUNTER LED LIGHTS, TYPE F. PROVIDE STEP DOWN
TRANSFORMER AS REQUIRED. COORDINATE WITH ARCHITECT/OWNER
FOR SWITCH LOCATION. REFER TO LUMINAIRE SCHEDULE FOR ADDITIONAL
INFORMATION AND REQUIREMENTS.
VERIFY TELE/DATA (CATV) DEVICE LOCATIONS WITH OWNER'S
AUTHORIZED REPRESENTATIVE PRIOR TO ROUGH IN. LOCATE AND
PROVIDE ALL EQUIPMENT ASDIRECTED FOR A COMPLETE AND OPERATION
INSTALLATION. PROVIDE DUPLEX RECEPTACLE ADJACENT TO ALL
TELE/DATA AND CATV DEVICES, TYPICAL. DO NOT INSTALL ANY LOW
VOLTAGE SYSTEMS BASED ON THIS UNIT PLAN.
PROVIDE 250V 30A 2PST DISCONNECT SWITCH TO EWH PER EQUIPMENT
MFR NAMEPLATE AND FINAL WP FLEXIBLE CONNECTION TO MECHANICAL
EQUIPMENT INDICATED. VERIFY WITH MECHANICAL OR PLUMBING
CONTRACTOR EXACT LOCATION PRIOR TO ANY INSTALLATION AND
LOCATE AS REQUIRED. BASIS OF DESIGN: PROGRESS P2501-09 IN
BRUSHED NICKEL WITH LIGHT KIT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
GENERAL NOTES:
ELECTRICAL CONTRACTOR (EC) SHALL BE COMPLETELY RESPONSIBLE TO PROVIDE AND PROPERLY LOCATE ALL REQUIRED RECEPTACLES IN
DWELLING UNITS AS REQUIRED TO COMPLY WITH NEC 210.52 REQUIREMENTS WITHOUT EXCEPTION. RECEPTACLE SPACING IN LIVING, DINING,
BEDROOM, HALLWAYS, ETC. SHALL HAVE A RECEPTACLE NO GREATER THAN 6 FEET FROM ANY POINT ALONG THE WALL, FOR WALLS GREATER THAN
24 INCHES. KITCHEN RECEPTACLE SPACING AT COUNTERTOPS, ISLANDS, ETC. SHALL HAVE A RECEPTACLE NO MORE THAN 24 INCHES FROM ANY
POINT ALONG WALL FOR WALLS GREATER THAN 12 INCHES. PROVIDE AFCI PROTECTION PER NEC 210.12(A). RECEPTACLES SHALL BE TAMPER-
RESISTANT PER NEC 406.12(A)(1) REQUIREMENTS. GFCI PROTECTION SHALL BE PROVIDED FOR ALL DEVICES AND/OR CIRCUITS PER NEC 210.8. GFCI
PROTECTION SHALL BE PROVIDED FOR OUTLETS THAT SUPPLY DISHWASHERS PER 2017 NEC 210.8(D) REQUIREMENTS. CONTRACTOR SHALL PROVIDE
ALL GENERAL-USE CONVENIENCE RECEPTACLES AS REQUIRED IN ALL DWELLING UNITS PER NEC 210.52 REQUIREMENTS WHETHER INDICATED ON
THE DRAWINGS OR NOT. NOT EVERY REQUIRED OUTLET MAY BE SHOWN CORRECTLY LOCATED ON THE DWELLING UNIT LAYOUTS PROVIDED.
CONTRACTOR SHALL INCLUDE ALL FLOOR OUTLETS AS MAY BE REQUIRED PER NEC 210.52(A)(2) WHETHER INDICATED ON THE DRAWINGS OR NOT IF
REQUIRED TO MEET MINIMUM CODE REQUIREMENTS BY THE IAHJ. PROVIDE WP GFCI RECEPTACLE AT ALL DWELLING UNIT BALCONIES PER NEC
210.52(E)(3) REQUIREMENTS. DWELLING UNIT LAYOUTS ARE PROVIDED FOR GENERAL REQUIREMENTS AND INFORMATION ONLY AND ARE NOT
SPECIFIC INSTALLATION DRAWINGS INDICATING EXACT LOCATION OF ALL DEVICES OR EQUIPMENT OR DETAILING EVERY INSTALLATION REQUIREMENT
TO MEET ALL APPLICABLE CODES AND ADOPTED AMENDMENTS TO THE SATISFACTION OF THE IAHJ. IT SHALL BE THE SOLE RESPONSIBILITY OF THE
ELECTRICAL CONTRACTOR TO INCLUDE ALL LABOR AND MATERIALS IN BASE BID PROPOSAL FOR ALL ITEMS REQUIRED FOR A COMPLETE AND
OPERABLE INSTALLATION TO THE SATISFACTION OF THE IAHJ. NO RFI'S OR CHANGE ORDERS WILL EVEN BE CONSIDERED, REVIEWED OR APPROVED
FOR ANY REQUIRED ADDITIONAL ITEMS AS NOTED ABOVE AS MAY BE REQUIRED BY THE IAHJ DURING ROUGH AND/OR FINAL INSPECTION. IT IS
EXPECTED THAT THE ELECTRICAL CONTRACTOR HAS PROVIDED THE REQUIRED FUNCTION AS A LICENSED ELECTRICAL CONTRACTOR WHILE
PREPARING A CONSTRUCTION ESTIMATE AND BID PROPOSAL THAT ACCOUNTS FOR AND INCLUDES ALL SCOPE OF WORK REQUIRED FOR A COMPLETE
AND OPERABLE INSTALLATION ACCEPTABLE TO THE IAHJ IN ACCORDANCE WITH NEC 210.52 REQUIREMENTS.
PROVIDE AND INSTALL WP GFCI MAINTENANCE RECEPTACLES PER NEC 210.63 AT ALL GROUND MOUNTED AND/OR ROOF MOUNTED HACR EQUIPMENT
WHETHER INDICATED ON THE DRAWINGS OR NOT. PROVIDE DEDICATED 20A 120V BRANCH CIRCUIT FROM NEAREST AVAILABLE HOUSE PANEL IF NO
BRANCH CIRCUIT IS INDICATED ON THE DRAWINGS. PROVIDE 10AWG THWN CU CONDUCTORS FOR CIRCUITS IN EXCESS OF 75' IN LENGTH AND 8AWG
THHN CU CONDUCTORS FOR CIRCUITS IN EXCESS OF 125' IN LENGTH, TYPICAL FOR ALL BUILDINGS.
COORDINATE ALL INTERIOR AND EXTERIOR RECEPTACLE/LUMINAIRE INSTALLATIONS IN/ON EXTERIOR LOAD-BEARING PARTITIONS WITH GENERAL
CONTRACTOR TO ENSURE THERE ARE NO CONFLICTS WITH STUD PACKS OR SHEAR WALL SYSTEMS. DO NOT MODIFY ANY STRUCTURAL ELEMENT
WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. ALL BACKBOXES REQUIRED FOR DEVICES/LUMINAIRES SHALL
BE RECESS MOUNTED. COORDINATE FUR-OUT OF WALL OR PROVIDE FLOOR MOUNTED RECEPTACLE AS NECESSARY FOR INTERIOR OUTLETS. FINAL
INSTALLATION SHALL BE ACCEPTABLE THE IAHJ AND OAR. DO NOT SUBMIT AN RFI FOR THESE CONDITIONS OR REQUEST SPECIFIC INSTALLATION
DETAILS UNLESS DESIGN DIRECTION IS ABSOLUTELY REQUIRED TO RESOLVE THE CONDITION. CONTRACTORS SHALL BE RESPONSIBLE TO FIELD
COORDINATE ALL OCCURENCES AND SHALL BE RESPSONSIBLE FOR ALL INSTALLATION MEANS AND METHODS FOR A COMPLETE AND OPERABLE
INSTALLATION TO SUIT THE APPLICATION.
LOCATE ALL ELECTRICAL EQUIPMENT TO PROVIDE ALL REQUIRED WORKING CLEARANCES PER NEC 110.26 REQUIREMENTS TO THE SATISFACTION OF
THE IAHJ.
COORDINATE WITH MECHANICAL AND PLUMBING DRAWINGS/CONTRACTORS FOR EXACT LOCATIONS OF ALL EQUIPMENT. VERIFY POINT OF SERVICE
AND ROUTE FEEDER/BRANCH CIRCUIT WIRING AS REQUIRED TO SUIT FIELD CONDITIONS. ROUTE ALL WIRING OUT OF PUBLIC VIEW AS MUCH AS
POSSIBLE.
REFER TO ARCHITECTURAL OR INTERIOR DESIGNER REFLECTED CEILING PLANS (RCP) FOR EXACT LOCATION OF ALL LUMINAIRES. IF NO RCP IS
PROVIDED, LOCATE ALL LUMINAIRES TO BEST ILLUMINATE THE SPACE AND CENTERED IN AVAILABLE SPACE COORDINATED WITH ALL OTHER CEILING
ITEMS SUCH AS MECHANICAL EQUIPMENT OR LIFE SAFETY SYSTEM DEVICES. COORDINATE ALL LOCATIONS WITH OAR DURING BOX WALK PRIOR TO
ANY WIRING INSTALLATION TO ENSURE ACCEPTABLE INSTALLATION PRIOR TO INSTALLATION OF ANY WIRING.
ALL EQUIPMENT EXPOSED TO WEATHER SHALL BE NEMA 3R RATED TO SUIT THE APPLICATION.
THE ELECTRICAL CONTRACTOR SHALL BE COMPLETELY RESPONSIBLE FOR DETERMINING AND PROVIDING ALL PROPER WIRING MEANS AND
METHODS FOR ALL BUILDING TYPES, CONDITIONS/APPLICATIONS, COORDINATION OF ROUTING AND INSTALLATION OF ALL FEEDERS AND
INSTALLATION OF ALL EQUPMENT PER ALL APPLICABLE CODES WITH ALL OTHER TRADES PRIOR TO ANY INSTALLATION TO THE SATISFACTION OF THE
IAHJ. WHERE WIRING MEANS OR METHODS ARE INDICATED ON THESE DRAWINGS THEY ARE MINIMUM REQUIREMENTS ONLY AND THE ELECTRICAL
CONTRACTOR SHALL CONFIRM ACCEPTABLE INSTALLATION METHODS AND MATERIALS WITH THE IAHJ PRIOR TO ANY INSTALLATION, TYPICAL.
VERIFY ALL DEVICE TYPE, COLOR AND MATCHING COVER PLATE COLOR WITH OAR AND/OR ARCHITECT. DEVICE ORIENTATION SHALL BE VERTICAL
UNLESS OTHERWISE INDICATED OR DIRECTED BY OAR/ARCHITECT. VERIFY EXACT REQUIREMENTS PRIOR TO ANY INSTALLATION AND INSTALL ALL
EQUIPMENT AS DIRECTED.
PROVIDE APPROVED CO DETECTOR OR APPROVED COMBINATION SMOKE/CO DETECTOR IN ALL DWELLING UNITS WHERE REQUIRED TO THE
SATISFACTION OF THE IAHJ. ALL EQUIPMENT PROVIDED SHALL HAVE 120V PRIMARY POWER WITH BATTERY BACKUP PER APPLICABLE CODE
REQUIREMENTS.
IT IS FULLY EXPECTED AND REQUIRED THAT THE EC SHALL BE RESPONSIBLE TO THOROUGHLY COORDINATE WITH ARCHITECTURAL PLANS, INTERIOR
ELEVATIONS, ALL APPLIANCE INSTALLATION MANUALS AND FINAL APPROVED MILLWORK VENDOR SHOP DRAWINGS TO VERIFY ALL REQUIREMENTS
FOR ELECTRICAL CONNECTIONS AND EXACT LOCATIONS WITHIN MILLWORK PRIOR TO ANY INSTALLATION. PROVIDE ALL BACKBOXES, OULETS,
SUPPORTS, ETC. AS REQUIRED FOR A COMPLETE AND OPERABLE INSTALLATION. NOTES ON DRAWINGS HAVE BEEN PROVIDED TO ALERT
CONTRACTOR TO VARIOUS ITEMS/ISSUES BUT SHALL NOT BE CONSTRUED AS BEING COMPLETE IN ANY WAY. ENGINEER ASSUMES NO LIABILITY FOR
OUTLET/CONNECTION TYPE/DEVICE LOCATIONS, ETC. FOR ANY DEVICE OR CONNECTION INSTALLED WITHIN DWELLING UNITS. ELECTRICAL
CONTRACTOR SHALL PROVIDE ALL REQUIRED COORDINATION WITH KITCHEN EQUIPMENT/APPLIANCE VENDORS AND SHOP DRAWINGS, ALL MILLWORK
SHOP DRAWINGS/CONTRACTOR AND OAR TO ENSURE ALL EQUIPMENT IS PROPERLY ACCOUNTED FOR AND CORRECTLY LOCATED PRIOR TO ANY
INSTALLATION TO AVOID ANY CONFLICTS DURING ACTUAL INSTALLATION.
EC SHALL SCHEDULE A "BOX WALK" WITH OAR AFTER ALL OUTLET BOXES HAVE BEEN INSTALLED, BUT PRIOR TO INSTALLING ANY WIRING TO VERIFY
EXACT LOCATION OF ALL DEVICES. ONCE OAR CONFIRMS APPROVAL OF ALL LOCATIONS, ROUGH WIRING MAY OCCUR. ANY ROUGH WIRING
INSTALLED PRIOR TO BOX WALK AND OAR APPROVAL SHALL BE AT CONTRACTORS SOLE RISK AND SHALL BE RELOCATED OR RECONFIGURED AT
CONTRACTORS SOLE EXPENSE IF INSTALLED WIRING DOES NOT MEET PROJECT REQUIREMENTS AS DETERMINED BY OAR.
IT IS FULLY EXPECTED AND REQUIRED THAT THE EC SELECTED AND AWARDED THE CONTRACT FOR THIS PROJECT WILL HAVE PREVIOUSLY
PERFORMED MANY PROJECTS SIMILAR TO THIS PROJECT'S SIZE AND SCOPE AND THEREFORE IS FULLY PREPARED AND ABLE TO UNDERSTAND THE
REQUIRED SCOPE OF WORK AND IN FACT HAS INCLUDED ALL THE NECESSARY COORDINATION, PRE-PLANNING AND ADDITIONAL SCOPE OF WORK
THAT IS REQUIRED TO SUCCESSFULLY COMPLETE A PROJECT OF THIS SIZE AND SCOPE WITHOUT UNNECESSARY RFI'S, QUESTIONS OR NEED FOR
SPECIFIC ADDITIONAL DIRECTION FROM THE DESIGN TEAM ON COMPLETING THE PROJECT. PROJECT EXECUTION BY THE ELECTRICAL CONTRACTOR
SHALL INCLUDE THE PROPER LAYOUT AND INSTALLATION OF ALL REQUIRED BRANCH CIRCUITING PER 2017 NEC ARTICLE 210 AS AMENDED BY THE
CITY OF LONE TREE PER SEC. 18-7-40. THE OWNER EXPECTS THIS LEVEL OF EXPERIENCE AND COMPETENCE SHALL RESULT IN A PROJECT WITHOUT
UNDUE RFI'S AND CHANGE ORDERS FOR "MISSING ITEMS" THAT MAY NOT BE EXPLICITLY INDICATED ON THE DRAWINGS, BUT ARE NECESSARY FOR A
COMPLETE AND OPERABLE INSTALLATION. REFER TO GENERAL NOTES ABOVE FOR ADDITIONAL EXPECTATIONS AND REQUIREMENTS TO BE
INCLUDED IN THE CONTRACTORS BASE SCOPE OF WORK AND SPECIFIC CONTRACT REQUIREMENTS.
PER 2018 IECC R404.1; NOT LESS THAN 90% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH-EFFICACY LAMPS.
CONTRACTOR SHALL PROVIDE ALL DOCUMENTATION TO IAHJ AS MAY BE REQUIRED FOR CERTIFICATION AND APPROVAL FOR OCCUPANCY.
ELECTRICAL CONTRACTOR (EC) SHALL FULLY COORDINATE WITH OWNERS LOW VOLTAGE DESIGN CONSULTANT (LVDC) TO INCLUDE ALL SCOPE
ELEMENTS FOR ALL LOW VOLTAGE SYSTEMS TO AND WITHIN ALL DWELLING UNITS. EC SHALL OBTAIN FINAL APPROVED LVDC DELEGATED DESIGN
DRAWINGS AND SHALL INCLUDE ALL SCOPE ITEMS AS REQUIRED FOR A COMPLETE AND OPERABLE INSTALLATION. VERIFY EXACT LOCATION AND
DEVICE TYPES WITH LVDC DRAWINGS AND OAR PRIOR TO ANY INSTALLATION. LV DEVICE LOCATIONS INDICATED HEREON ARE FOR REFERENCE USE
ONLY AND ARE NOT TO BE USED FOR DETERMINING INSTALLATION REQUIREMENTS OR REQUIRED SCOPE OF WORK. EC SHALL PROVIDE SEPARATE
LINE ITEM PRICING AS DIRECTED BY OAR FOR ALL LOW VOLTAGE SCOPE AS PART OF BASE BID PROPOSAL FOR A COMPLETE AND OPERABLE
INSTALLATION.
REFER TO EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION FOR EQUIPMENT INSTALLATION AND CONNECTION REQUIREMENTS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
1
1
1
2
2
1 ABCO COMMENTS 02/02/2023
2 VE CHANGES 03/03/23G3/3/2023
A A
A
A
A
A
A
A
A
A
A
A
A
A
AA
A
E
B
B
B
C
G
A
1
TYP.S
S
S
3
2
2
4
5
6
7
9
10
TYP.11
12
13 TYP.
14
15
10
16
17
18
20
19
EWH-1
3
3
TV
TV
TV 15
21
21
D D
D
TYP.22
VTAC-2
EF-1
EF-13023
F
F
A A
A A
A
A
A
A
AA
A
AA
B
B
B
C
G
E
16
TYP.
S
2
1
2
3
4
5
6
7
8
9
10
A
TYP.11
12
13 TYP.
14
S
17
GFI
18
GFI
20
A
A
A
LIVING/ DINING
ROOM
24
KITCHEN
28
W.I.C
148
FOYER
31
M.BEDROOM
10
M.BATH
32
MECH
33
BATH
13
BEDROOM
9
A
AC
GFI
S
19TVTV
TV
19
GWH-1
15
15
21
21
A
D
D D
22 TYP.
F
F
19
VTAC-2
TV
A AA
11TYP.
13 TYP.
S
A A
A A
TV
22 TYP.
E
6
A
A
14
20
EWH-1
305
1
3
2
2
17
21
21 A
A
B
B
B
7
9
S
16
F
F
15
EF-1
10
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E402
ELECTRICAL UNIT
PLANS
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 ELECTRICAL UNIT PLAN - 2 BEDROOM TYPE 5
XKEYED NOTES:
PROVIDE DEDICATED 15A 120V BRANCH CIRCUIT AND OUTLET FOR
REFRIGERATOR. REFER TO DWELLING UNIT PANEL SCHEDULE FOR
ADDITIONAL INFORMATION AND REQUIREMENTS. LOCATE PER EQUIPMENT
MFR SPECIFICATIONS.
PROVIDE ABOVE-COUNTER DUPLEX GFCI RECEPTACLES FOR SMALL
APPLIANCES PER NEC 210.52(B)(3) AND 210.52(C) REQUIREMENTS.
INSTALLATION SHALL COMPLY WITH NEC 210.8(A) AND 210.12(A) TO THE
SATISFACTION OF THE INSPECTING AUTHORITY HAVING JURISDICTION.
PROVIDE 50A 250V 4-WIRE NEMA 14-50R RECEPTACLE FOR RANGE/OVEN
OR PER EQUIPMENT MFR SPECIFICATIONS AS DIRECTED BY OWNERS
AUTHORIZED REPRESENTATIVE. VERIFY EXACT LOCATION AND
REQUIREMENTS PRIOR TO ANY INSTALLATION.
REFER TO ARCHITECTURAL DRAWINGS AND DETAILS AND COORDINATE
WITH GENERAL CONTRACTOR FOR ALL LUMINAIRES. PROVIDE ALL
EQUIPMENT AS DIRECTED FOR A COMPLETE AND OPERABLE
INSTALLATION.
PROVIDE 30A 250V 4-WIRE NEMA 14-30R RECEPTACLE FOR DRYER UNIT OR
PER EQUIPMENT MFR SPECIFICATIONS. COORDINATE WITH OWNERS
EQUIPMENT VENDOR TO PROVIDE CONNECTION TO 65VA REMOTE IN-LINE
FAN AND CONNECT TO DRYER AS REQUIRED. RE: MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
PROVIDE EXTERIOR OUTLETS PER NEC 210.52(E)(2) & (3) REQUIREMENTS
TO THE SATISFACTION OF THE INSPECTING AUTHORITY HAVING
JURISDICTION.
PROVIDE BELOW-COUNTER SWITCHED RECEPTACLE FOR GARBAGE
DISPOSAL. PROVIDE DEDICATED BRANCH CIRCUIT AND SPST AIR SWITCH
CONTROLLER, FLUSH IN COUNTER. COORDINATE INSTALLATION AND
LOCATION OF ALL DEVICES IN MILLWORK WITH GENERAL CONTRACTOR
AND MILLWORK VENDOR PRIOR TO ANY INSTALLATION. PROVIDE CORD
AND PLUG IF NOT PROVIDED BY PLUMBING CONTRACTOR.
PROVIDE RECEPTACLE LISTED FOR USE IN COUNTERTOPS AS REQUIRED
PER NEC 210.52(C)(5) ADJACENT TO SINK. PROVIDE GFCI PROTECTION AS
REQUIRED. COORDINATE INSTALLATION WITH MILLWORK VENDOR AND
GENERAL CONTRACTOR PRIOR TO ANY INSTALLATION.
PROVIDE DEDICATED 20A GFCI BRANCH CIRCUIT FOR DISHWASHER.
LOCATE OUTLET UNDER SINK AND LABEL AS DISHWASHER. COORDINATE
INSTALLATION WITH PLUMBING CONTRACTOR AND LOCATION OF ALL
DEVICES IN MILLWORK PRIOR TO ANY INSTALLATION. PROVIDE GFCI
PROTECTION PER NEC 210.8(D).
PROVIDE DEDICATED 20A GFCI BRANCH CIRCUIT TO SERVE DWELLING
UNIT BATHROOMS PER NEC 210.11(C)(3), 210.8(A)(1) AND 210.52(D)
REQUIREMENTS. LOCATE AT SIDEWALL ADJACENT TO MIRROR TO SUIT
EACH CONDITION. DO NOT LOCATE IN MIRROR. VERIFY EXACT LOCATION
WITH ARCHITECT PRIOR TO ROUGH IN AND LOCATE AS DIRECTED.
PROVIDE GENERAL PURPOSE CONVENIENCE OUTLETS THROUGHOUT
DWELLING UNITS PER NEC 210.52 REQUIREMENTS, TYPICAL. VERIFY
EXACT LOCATION OF ALL DEVICES FOR SPECIAL EQUIPMENT SUCH AS
TV'S, ETC. PRIOR TO ROUGH IN AND LOCATE AS DIRECTED.
PROVIDE "MEDIA BOX" FOR LOW VOLTAGE SYSTEMS DISTRIBUTION WITHIN
DWELLING UNIT. PROVIDE ADDITIONAL 120V RECEPTACLE IF REQUIRED.
PROVIDE TELE/DATA CABLING THROUGHOUT DWELLING TO DEVICES AS
REQUIRED.
PROVIDE FAN-RATED CEILING BOX PER NEC 314.27(C). LOCATED AS
DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. PROVIDE 3-WIRE
CONNECTION FOR POSSIBLE FAN/CONTROL AS DIRECTED.
PROPOSED LOCATION OF DWELLING UNIT PANEL. COORDINATE EXACT
LOCATION WITH ARCHITECT AND GENERAL/MECHANICAL CONTRACTORS
PRIOR TO ANY INSTALLATION TO AVOID CONFLICTS WITH OTHER SYSTEMS.
FINAL LOCATION AND INSTALLATION SHALL PROVIDE ALL WORKING
CLEARANCES REQUIRED PER NEC 110.26 REQUIREMENTS. DO NOT
LOCATE PANEL IN CLOTHES CLOSET OR RESTROOMS.
PROVIDE 120V CONNECTION TO EXHAUST FAN. COORDINATE EXACT
REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ANY
INSTALLATION. PROVIDE ALL EQUIPMENT FOR A COMPLETE AND
OPERABLE INSTALLATION. PROVIDE SEPARATE CONTROL SWITCH AS
DIRECTED BY OWNERS AUTHORIZED REPRESENTATIVE.
PROVIDE 120V CONNECTION AND INSTALL UL 217 SMOKE DETECTOR(S)
PER IBC 907.2.11.2 REQUIREMENTS. INTERCONNECT MULTIPLE ALARMS AS
REQUIRED PER IBC 907.2.11.5. INSTALLATION TO BE TO THE SATISFACTION
OF THE INSPECTING AUTHORITY HAVING JURISDICTION (IAHJ). PROVIDE
COMBINATION SMOKE/CO DETECTOR IF ACCEPTABLE TO IAHJ.
PROVIDE DEDICATED 20A 120V BRANCH CIRCUIT TO COMBO MICROWAVE /
RECIRC VENT, TYPICAL ALL NON-ADA UNITS. COORDINATE EXACT
LOCATION AND ALL EQUIPMENT REQUIREMENTS WITH MECHANICAL
CONTRACTOR PRIOR TO ANY INSTALLATION. PROVIDE ALL EQUIPMENT
FOR A COMPLETE AND OPERABLE INSTALLATION.
PROVIDE DEDICATED 20A 120V BRANCH CIRCUIT FOR LAUNDRY
EQUIPMENT PER NEC 210.11(C)(2) AND 210.52(F) REQUIREMENTS. VERIFY
EXACT LOCATION PRIOR TO ROUGH IN AND LOCATE AS DIRECTED.
VERIFY EXACT LOCATION AND REQUIREMENTS WITH MECHANICAL
CONTRACTOR PRIOR TO ANY INSTALLATION. REFER TO GENERAL NOTES
ABOVE FOR ADDITIONAL REQUIREMENTS. REFER TO EQUIPMENT
SCHEDULE FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
STUB OUT 1/2" CONDUIT ABOVE CEILING FROM ENTRY DOOR/FRAME
ASSEMBLY FOR ACCESS CONTROL/DOOR STRIKE (BY OTHERS).
UNDERCOUNTER LED LIGHTS, TYPE F. PROVIDE STEP DOWN
TRANSFORMER AS REQUIRED. COORDINATE WITH ARCHITECT/OWNER
FOR SWITCH LOCATION. REFER TO LUMINAIRE SCHEDULE FOR ADDITIONAL
INFORMATION AND REQUIREMENTS.
VERIFY TELE/DATA (CATV) DEVICE LOCATIONS WITH OWNER'S
AUTHORIZED REPRESENTATIVE PRIOR TO ROUGH IN. LOCATE AND
PROVIDE ALL EQUIPMENT ASDIRECTED FOR A COMPLETE AND OPERATION
INSTALLATION. PROVIDE DUPLEX RECEPTACLE ADJACENT TO ALL
TELE/DATA AND CATV DEVICES, TYPICAL. DO NOT INSTALL ANY LOW
VOLTAGE SYSTEMS BASED ON THIS UNIT PLAN.
PROVIDE 250V 30A 2PST DISCONNECT SWITCH TO EWH PER EQUIPMENT
MFR NAMEPLATE AND FINAL WP FLEXIBLE CONNECTION TO MECHANICAL
EQUIPMENT INDICATED. VERIFY WITH MECHANICAL OR PLUMBING
CONTRACTOR EXACT LOCATION PRIOR TO ANY INSTALLATION AND
LOCATE AS REQUIRED. BASIS OF DESIGN: PROGRESS P2501-09 IN
BRUSHED NICKEL WITH LIGHT KIT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
GENERAL NOTES:
REFER TO GENERAL NOTES ON SHEET E401.1.
1/4" = 1'-0"2 ELECTRICAL UNIT PLAN - 2 BEDROOM TYPE 4
1
1
1
1/4" = 1'-0"3 ELECTRICAL UNIT PLAN - 1 BEDROOM TYPE 1
2
2
2
1 ABCO COMMENTS 02/02/2023
2 VE CHANGES 03/03/23G3/3/2023
ONE-LINE DIAGRAM GENERAL NOTES:
1. ALL SERVICE EQUIPMENT SHALL BE INSTALLED PER NEC REQUIREMENTS AND UTILITY PROVIDER'S SERVICE STANDARDS.
2. ALL DISTRIBUTION EQUIPMENT AND OVERCURRENT DEVICES INDICATED SHALL BE NEW AND IDENTIFIED AS A UL LISTED SERIES TESTED
COMBINATION WITH UPSTREAM FUSE PER NEC 240.86(B) WHERE REQUIRED FOR SCCR RATING INDICATED. PROVIDE ALL EQUIPMENT LABELING
PER NEC 110.22(C). PROVIDE SUBMITTAL DATA FOR REVIEW AND APPROVAL BY ARCHITECT/ENGINEER PRIOR TO ORDERING OR PURCHASING
ANY EQUIPMENT.
3. UTILITY SERVICE EQUIPMENT SHALL BE SHALL BE GROUNDED AND BONDED IN ACCORDANCE WITH NEC 250.80 AND 250.84 REQUIREMENTS.
4. ALL SERVICE EQUIPMENT SHALL BE GROUNDED AND BONDED IN ACCORDANCE WITH NEC 250.24 AND 250.92 REQUIREMENTS.
5. CONTRACTOR'S SERVICE EQUIPMENT VENDOR SHALL PROVIDE ALL REQUIRED ARC FLASH SYSTEM ANALYSIS, DOCUMENTATION AND
EQUIPMENT LABELING PER NEC 110.16, 110.21, 110.22 AND 240.87 REQUIREMENTS TO THE SATISFACTION OF THE INSPECTING AUTHORITY HAVING
JURISDICTION.
6. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL NEW ELECTRICAL SERVICE INSTALLATION REQUIREMENTS WITH UTILITY
AUTHORIZED SERVICE REPRESENTATIVE. COORDINATE EXACT LOCATION OF ALL SITE UTILITIES AND EQUIPMENT WITH FINAL APPROVED UTILITY
SERVICE PLAN. PROVIDE INSTALLATION OF ALL RACEWAY SYSTEMS AND EQUIPMENT AS REQUIRED FOR NEW SERVICE TO BUILDING PER
UTILITY SERVICE STANDARDS AND FINAL APPROVED SERVICE PLAN.
7. ALL SITEWORK AND UNDERGROUND CONDUIT SHALL BE PER UTILITY PROVIDER'S GUIDE FOR CUSTOMER INSTALLED UNDERGROUND CONDUITS
AND VAULTS PRIMARY INSTALLATION AND LATEST ELECTRIC SERVICE CONSTRUCTION STANDARDS (ESCS). VERIFY EXACT REQUIREMENTS
PRIOR TO BID.
8. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH SERVING UTILITIES FOR ALL LOW VOLTAGE SYSTEM SERVICES TO THE BUILDING
INCLUDING, BUT NOT LIMITED TO, TELEPHONE, CATV, SECURITY SYSTEMS, ETC. PROVIDE ALL RACEWAYS AND STRUCTURES AS REQUIRED BY
SERVING UTILITY COMPANIES FOR RESPECTIVE SYSTEMS IN BASE BID PROPOSAL.
9. CONTRACTOR SHALL SUBMIT FOR REVIEW AND APPROVAL EQUIPMENT SHOP DRAWINGS FOR ALL SERVICE ENTRANCE EQUIPMENT,
DISTRIBUTION EQUIPMENT, PANELBOARDS, OR OTHER RELATED EQUIPMENT.
10. ALL ELECTRICAL SERVICE AND DISTRIBUTION EQUIPMENT EXPOSED TO WEATHER SHALL BE NEMA 3R RATED WEATHERPROOF.
11. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING APPLICABLE WIRING MEANS AND METHODS TO SUIT SPECIFIC FIELD
CONDITIONS TO SUIT THE INTENDED APPLICATION. PROVIDE ALL RACEWAYS AND EQUIPMENT PER APPLICABLE CODE REQUIREMENTS. WHERE
RACEWAY TYPES ARE INDICATED HEREON, THEY ARE FOR REFERENCE USE ONLY AND DO NOT NECESSARILY INDICATE THE SPECIFIC RACEWAY
TYPE REQUIRED FOR THE SPECIFIC APPLICATION IN ALL AREAS.
12. PROVIDE SUPPORT FOR ALL CONDUCTORS IN VERTICAL RACEWAYS AS REQUIRED PER NEC 300.19 TO THE SATISFACTION OF THE INSPECTING
AUTHORITY HAVING JURISDICTION.
DETAIL NOTES:
COORDINATE WITH OWNERS AUTHORIZED REPRESENTATIVE AND OBTAIN SERVING UTILITY COMPANY (HOLY CROSS ELECTRIC) TO PROVIDE
ELECTRONIC SUBMETERING AS PART OF BASE BID PROPOSAL FOR ALL DWELLING UNITS. INCLUDE ALL EQUIPMENT AND INSTALLATION REQUIRED
FOR A COMPLETE AND OPERABLE ELECTRONIC SUBMETERING SOLUTION. SYSTEM TO BE CAPABLE OF METERING AND ASSOCIATING MULTIPLE
FEEDERS AND BRANCH CIRCUITS TO A SINGLE UNIT.
PROVIDE CIRCUIT BREAKER AND BRANCH CIRCUIT SHOWN TO REMOTE ELECTRONIC SUBMETERING EQUIPMENT. COORDINATE WITH OWNERS
ELECTRONIC SUBMETERING VENDOR EXACT EQUIREMENTS AND EQUIPMENT LOCATIONS PRIOR TO ANY INSTALLATION. REFER TO GENERAL NOTE
25 ON E0.00 FOR ADDITIONAL INFORMATION AND REQUIREMENTS, TYPICAL.
PROVIDE 18AWG UL1015, 600V 221F/105C, TWISTED PAIR BLACK AND WHITE CONDUCTORS FOR CT WIRING FROM CT'S AT "MDP" TO REMOTE MMU.
COORDINATE WITH OWNERS ELECTRONIC SUBMETERING VENDOR EXACT REQUIREMENTS AND EQUIPMENT LOCATIONS PRIOR TO ANY
INSTALLATION. PROVIDE RACEWAY SYSTEM(S) AS REQUIRED TO SUIT THE SPECIFIC INSTALLATION REQUIREMENTS PER EQUIPMENT MFR
SPECIFICATIONS AS DIRECTED BY OWNERS ELECTRONIC SUBMETERING VENDOR.
PROVIDE ARC-ENERGY REDUCTION PER NEC 240.87 REQUIREMENTS.
ROUTE SPARE 1-1/4" CONDUIT FROM EACH TENANT PANEL TO INVERTER ROOM ON THE 1ST FLOOR. ROUTE A 1-1/4" CONDUIT FOR EACH UNIT FROM
INVERTER ROOM TO ROOF AND STUB OUT 1' ABOVE ROOF LEVEL. PROVIDE PULL STRINGS AND CAP OFF ENDS FOR EACH CONDUIT. THESE
CONDUITS ARE FOR FUTURE USE WITH ROOF MOUNTED PV SYSTEMS.
(ASSUMED)
300kVA
208/120V/3Φ
TRANSFORMER
BY HOLY CROSS
ELECTRIC
2
LEVEL 1
1600/3
200/3 60/3 225/2
"MDP", 1600A, 208/120V, 3Φ, 4W, NEMA 3R, 65kAIC
4 3 4
HOUSE
PANEL
"HP"
MCB
WATER
PIPE
UFER GROUND
ROD
UTILITY
METER
N
G
LEVEL 2
LEVEL 3
ESM
TENANT
PANEL
(x3)
MLO
X
1.
2.
3.
4.
5.
4
"MMU"1
2
3
60/2
3
GARAGE
PANEL
(x6)
MLO
3
8[(4-1000kcmil) 3-1/2"C]
6[(4-400kcmil) 3-1/2"C]
(4#4;#8GND) 1-1/4"C
(4-250kcmil;#4GND) 3"C
1
FEEDER SCHEDULE
2
3
4
NOTE: ALL CONDUCTORS SHOWN ARE ALUMINUM UNLESS OTHERWISE NOTED.
SECONDARY
CONNECTION
CABINET
4000A
1 #6 Cu GEC
#4 Cu GEC#3/0 Cu GEC
225/2
4
TENANT
PANEL
(x4)
MLO
3
X X - Isc=56,202
Isc=41,534 - X
Isc=21,519 - X
X - Isc=6,031 X - Isc=18,793
(WORST CASE)(WORST CASE)
225/2
4
TENANT
PANEL
(x4)
MLO
3
TO BLDG F
UM1-3
XFMR
VAULT
ROOF
INVERTER
ROOM
5
X - Isc=57,400
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E602
ELECTRICAL
ONE-LINE
DIAGRAM
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1 BUILDING G - ELECTRICAL ONE-LINE DIAGRAM
ALL CALCULATIONS BASED ON BUSSMAN POINT-TO-POINT METHOD FOR 3 PHASE CIRCUITS.
** FOR INFINITE BUS USE 100,000,000
* MULTIPLY THE TOTAL MOTOR LOAD CURRENT BY 4
1. Transformer short circuit rating based on information received from Holy Cross Metering Guidebook, Table II.
Unit Panel (Worst Case) 45 Al 250 kcmil 1 2 208 12862 41534 18793
Garage Panel (Worst Case) 40 Al #4 1 2 208 2350 41534 6031
PANEL 'HP' 50 Al 250 kcmil 1 2 208 18593 41534 21519
SWBD 'MDP' 110 Al 400 kcmil 6 2 208 145776 56202 41534
TERMINATION CABINET 10 Al 600 kcmil 8 2 208 224264 57400 56202
LOCATION FT. Cu SIZE PH. NON=2 L-L " C " Isc Isc
FAULT LEN. Al/ NO./ MAG=1 VOLT. CIRCUIT BEGINNI... FAULT
CKT COND... COND... CKT
FEEDERS
500kVA XFMR secondary 500 12470 208 1.41 1388 100000... 33400 0 57400
LOCATION KVA L-L L-L %Z FLA Isc** Isc CONTRIB. Isc
FAULT TRANS. VOLT. VOLT. XFMR SEC. PRI. SEC. *MOTOR CONTRIB.
PRI. SEC. XFMR. XFMR. TOTAL
TRANSFORMERS
LOCATION:Eagle Vail DATE:3/3/2023
PROJECT:Haymeadow PROJ. NO.:21234
SHORT CIRCUIT CALCULATIONS
2
2
2
2 VE CHANGES 03/03/23G3/3/2023
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E604
ELECTRICAL
SCHEDULES
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
LUMINAIRE SCHEDULE GENERAL NOTES
1 LUMINAIRES INDICATED ABOVE WERE USED AS A BASIS OF DESIGN; ALTERNATE MANUFACTURERS WILL BE CONSIDERED WITH ARCHITECT'S AND OWNER'S APPROVAL.
2 CATALOG NUMBERS INDICATE BASIC LUMINAIRE TYPES REQUIRED FOR THIS PROJECT. CONTRACTOR SHALL BE RESPONSIBLE TO INCLUDE ALL ACCESSORIES AND HARDWARE REQUIRED FOR FINAL INSTALLATION.
3 ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE FOR VERIFYING LUMINAIRE LOCATIONS AND MOUNTING REQUIREMENTS PRIOR TO PURCHASE. INCLUDE ALL MOUNTING HARDWARE AS REQUIRED FOR A COMPLETE INSTALLATION.
4 FINAL FINISH OF ALL FIXTURES SHALL BE APPROVED IN WRITING BY ARCHITECT.
5 MOUNTING HEIGHTS SHALL BE COORDINATED WITH ARCHITECT'S ELEVATIONS.
6 THE FIXTURE SCHEDULE DOES NOT NECESSARILY LIST ALL ACCESSORIES AND HARDWARE NECESSARY FOR THE COMPLETE INSTALLATION, NOR DOES IT DETAIL THE CEILING CONSTRUCTION TO BE ENCOUNTERED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROPERLY
DETERMINE AND PROVIDE CORR
7 FIXTURES AND TRACKS SHALL BE MOUNTED TO / FROM STRUCTURE IN A MANNER RECOMMENDED BY THE MANUFACTURER WITHOUT COMPROMISING THE INTEGRITY OF THE STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS REQUIRED TO INSURE A SAFE
AND PROPER INSTALLATION.
8 REMOTE TRANSFORMERS, POWER SUPPLIES, OR DRIVERS SHALL BE LOCATED IN NEARBY ACCESSIBLE, CONCEALED-FROM-VIEW LOCATION WITH MANUFACTURER'S RECOMMENDED VENTILATION. CONTRACTOR SHALL SUPPLY MANUFACTURER'S TRANSFORMERS, POWER
SUPPLIES, OR DRIVERS OF PROPER CAPACITY FOR A COMPLETE INSTALLATION.
LIGHTING FOR EXTERIOR APPLICATIONS SHALL COMPLY WITH IECC C405.2.5 AND MEET ALL OF THE FOLLOWING REQUIREMENTS:
1. LIGHTING SHALL BE CONTROLLED BY A DEVICE THAT AUTOMATICALLY TURNS OFF THE LIGHTING WHEN SUFFICIENT DAYLIGHT IS
AVAILABLE.
2. ALL BUILDING FACADE AND LANDSCAPE LIGHTING SHALL BE AUTOMATICALLY CONTROLLED AS A FUNCTION OF DUSK/DAWN AND A
SET BUSINESS OPENING AND CLOSING TIME, OR BETWEEN TIMES ESTABLISHED BY THE AUTHORITY HAVING JURISDICTION.
3. LIGHTING NOT SPECIFIED IN 2. SHALL BE CONTROLLED BY A DEVICE THAT AUTOMATICALLY REDUCES THE CONNECTED LIGHTING
POWER BY AT LEAST 30% FOR AT LEAST ONE OF THE FOLLOWING CONDITIONS:
A. FROM 12 MIDNIGHT OR WITHIN ONE (1) HOUR OF THE END OF BUSINESS OPERATIONS, WHICHEVER IS LATER, UNTIL 6A.M. OR
BUSINESS OPENING, WHICHEVER IS EARLIER.
B. DURING ANY PERIOD WHEN NO ACTIVITY HAS BEEN DETECTED FOR A TIME OF NO LONGER THAN 15 MINUTES.
ALL TIME SWITCHES SHALL BE CAPABLE OF RETAINING PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER FOR A
PERIOD OF AT LEAST TEN HOURS.
EXCEPTIONS:
1. LIGHTING FOR COVERED VEHICLE ENTRANCES OR EXITS FROM BUILDINGS OR PARKING STRUCTURES WHERE REQUIRED FOR
SAFETY, SECURITY, OR EYE ADAPTATION
2. LIGHTING THAT IS INTEGRAL TO SIGNAGE AND INSTALLED IN THE SIGNAGE BY THE MANUFACTURER
EXTERIOR LIGHTINGINTERIOR LIGHTING
LIGHTING FOR INTERIOR APPLICATIONS SHALL COMPLY WITH IECC C405.2 AND MEET ALL OF THE FOLLOWING REQUIREMENTS:
1. OFFICES
2. AUTOMATIC CONTROLS IN CORRIDORS SHALL HAVE THE FOLLOWING:
A. CONTROLLED TO AUTOMATICALLY TO TURN THE LIGHT 'ON' TO 50 PERCENT POWER UPON DIGITAL TIMECLOCK SETPOINT, 1-
HOUR BEFORE BUSINESS HOURS
a. OCCUPANT TO MANUALLY TURN 'ON' THE REMAINDER OF THE LIGHTING
b. OCCUPANT MANUAL CONTROLS TO BE FULLY CONTINUOUSLY DIMMABLE
B. LIGHT FIXTURES SHALL AUTOMATICALLY TURN 'OFF' 1-HOUR AFTER END OF BUSINESS HOURS
a. OCCUPANT TO MANUALLY TURN 'OFF' LIGHT FIXTURES
3. AUTOMATIC CONTROLS IN JANITOR CLOSETS, BATHROOMS, AND STORAGE ROOMS SHALL HAVE THE FOLLOWING:
A. AUTOMATICALLY TURN 'ON' THE LIGHT FIXTURES WHEN OCCUPANTS ENTER THE SPACE
B. MANUAL 'ON' OVERRIDE AT ENTRANCE DOOR
C. LIGHT FIXTURES SHALL AUTOMATICALLY TURN 'OFF' WITHIN 20-MINUTES OF ALL OCCUPANTS LEAVING THE SPACE
4. AUTOMATIC CONTROLS IN THE OPEN AREA WAREHOUSE SHALL HAVE THE FOLLOWING:
A. AUTOMATICALLY TURN 'ON' TO 50 PERCENT POWER WHEN OCCUPANTS ENTER THE SPACE
B. MANUAL 'ON' CONTROL AT EACH ENTRANCE DOOR
C. LIGHT FIXTURES SHALL AUTOMATICALLY TURN 'OFF' WITHIN 30-MINUTES OF ALL OCCUPANTS LEAVING THE SPACE
5. MECHANICAL, ELECTRICAL, AND WATER ENTRY ROOMS
A. AUTOMATIC CONTROLS NOT REQUIRED FOR OCCUPANT SAFETY. OCCUPANT TO MANUALLY TURN 'ON' AND MANUALLY TURN
'OFF' THE LIGHT FIXTURES
• LIGHTING CONTROLS SHALL BE PROVIDED BY LUTRON, LEVITON, GREENGATE, WATTSTOPPER, OR EQUIVALENT MANUFACTURER
AS APPROVED BY OWNER AND ENGINEER. PROVIDE MANUFACTURER'S SHOP DRAWINGS TO ARCHITECT FOR REVIEW PRIOR TO
PURCHASING.
• CONTROL SWITCHES, SENSORS, ETC. SHALL BE LOW-VOLTAGE OR WIRELESS WHENEVER PRACTICAL. INCLUDE ALL
ACCESSORIES, RELAY PACKS, CAT-# CABLING, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION.
• MANUAL DIMMING CONTROLS SHALL BE CAPABLE OF DIMMING LIGHTS TO 0% (OFF) SETTING. DIMMING COMPATIBILITIES
BETWEEN THE LUMINAIRES AND CONTROLS TO BE COORDINATED BY THE CONTRACTOR TO ENSURE PROPER OPERATION.
LUMINAIRES MUST BE ABLE TO DIM TO THE LEVEL INDICATED ON THE LUMINAIRE SCHEDULE.
• REMOTE LIGHTING CONTROL DEVICES (TIMECLOCKS, ETC.) SHALL BE CENTRALLY LOCATED IN ELECTRICAL ROOM, UNLESS
INDICATED OTHERWISE ON PLANS. COORDINATE AND CONFIRM WITH OWNER PRIOR TO ROUGH-IN.
• ALL SWITCHES AND SENSORS SHALL BE LABELED TO IDENTIFY THE AREA CONTROLLED.
• ELECTRICAL CONTRACTOR SHALL LOCATE SENSORS AS PROVIDED BY MANUFACTURER PER APPROVED SHOP DRAWINGS.
CONTROL LOCATIONS INDICATED ON THE DRAWINGS ARE FOR REFERENCE PURPOSES ONLY AND WILL BE ALTERED AS
NECESSARY FOR CORRECT OPERATION BY MANUFACTURER.
• PROJECT TO HAVE FUNCTIONAL PERFORMANCE TESTING OF ALL LIGHTING SYSTEMS AND PROVIDE OWNER WITH REPORT OF
DOCUMENTED PERFORMANCE WITHIN 90 DAYS OF RECEIPT OF CERTIFICATE OF OCCUPANCY. TESTING SHALL INCLUDE SYSTEM
COMMISSIONING AS REQUIRED BY IECC C408.
• DAYLIGHT RESPONSIVE CONTROLS SHALL BE PROVIDED WHERE REQUIRED PER IECC C405.2.3 REQUIREMENTS. LIGHTS AND
SENSORS IN THESE AREAS MUST BE INDEPENDENTLY CONTROLLED AND BE CAPABLE OF DIMMING FROM 10%-100%.
• PROGRAMMING, FACTORY START-UP AND TRAINING TO END-USER STAFF SHALL BE BY LIGHTING CONTROLS MANUFACTURER OR
AUTHERIZED REPRESENTATIVE. CONTRACTOR SHALL INCLUDE AT LEAST ONE FOLLOW-UP VISITS WITH LIGHITNG CONTROL
REPRESENTATIVE FOR FOLLOW-UP TRAINING OR ANY ADDITIONAL PROGRAMMING WITH OWNER IN BASE BID PROPOSAL.
• COMPLETE LIGHTING CONTROLS SYSTEM SHALL BE AS SIMPLIFIED AS ALLOWED BY IECC C405.2. STAND-ALONE AND SINGLE
ROOM CONTROLS IS PREFERED OVER CENTRAL CONTROL PANELS. DESIGN ALTERNATES AS ALLOWED BY CODE TO SIMPLIFY
THE DESIGN SHALL BE CONSIDERED AND REVIEWED BY THE ENGINEER WHERE PROPOSED BY CONTROLS MANUFACTURER OR
CONTRACTOR.
GENERAL REQUIREMENTS
LIGHTING CONTROLS REQUIREMENTS
LUMINAIRE SCHEDULE - ALTERNATE LIGHT FIXTURES AND CONTROLS
1 THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ANY INCURRED HOURS REQUIRED TO UPDATE THE PERMIT OR CONSTRUCTION DOCUMENTS DUE TO ALTERNATE FIXTURES OR CONTROLS BY THE ENGINEER OF RECORD.
2 THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ANY INCURRED HOURS REQUIRED FOR THE ENGINEER OF RECORD TO REVIEW ALTERNATE LIGHT FIXTURES OR CONTROLS.
3 UPDATES SHALL BE BILLED AT AN HOURLY RATE OF $150/HR OR AS PREVIOUSLY AGREED TO RATES IN THE CONTRACT DOCUMENTS.
LUMINAIRE SCHEDULE NOTES: ALL LUMINAIRES, LAMPS/DRIVERS, ACCESSORIES SHALL BE PROVIDED BY CONTRACTOR AS PART OF BASE BID SCOPE.
HC620D010-HM60525-830
G 6" LED SHOWER LIGHT HALO RECESSED 120V 21 3000K 80 2228 - WET LISTED
LED-T24P-1-1-WTFUNDERCOUNTER LED STRIP... WAC LIGHTING SURFACE 120V 3 3000K - - - PROVIDE REQUIRED STEP-DOWN TRANSFORMER\POWER...
HS71003-125EEXTERIOR WALL SCONCE HOMESTYLE LIGHTING WALL 120V 14 3000K - 1440 - WET LISTED, INSTALL 14W A19 LED LAMP
P2708-09
D BATHROOM VANITY LIGHT PROGRESS LIGHTING WALL 120V 42 3000K - 4320 - INSTALL (3) 14W A19 LED LAMPS
P500149-143
C DINING RM LED PENDANT PROGRESS LIGHTING PENDANT 120V 14 3000K - 1440 - INSTALL 14W A19 LED LAMP
PD-26611-SN
B 4" ROUND LED PENDANT WAC LIGHTING PENDANT 120V 15 3000K 90 858 ELV, 10%
HC620D010-HM60525-830
A 6" LED DOWNLIGHT HALO RECESSED 120V 21 3000K 80 2228 -
CATALOG NUMBER
TYPE DESCRIPTION MANUFACTURER & MOUNTING VOLTAGE WATTAGE CCT CRI LUMENS DIMMING REMARKS
UNIT LUMINAIRE SCHEDULE
LUMINAIRE SCHEDULE NOTES: ALL LUMINAIRES, LAMPS/DRIVERS, ACCESSORIES SHALL BE PROVIDED BY CONTRACTOR AS PART OF BASE BID SCOPE.
90-MINUTE BACKUP BATT. SQ-LED-W-SD
EM EMERGENCY LIGHT MULE WALL 120-277V - - - - -
90-MINUTE BACKUP BATT. HCXUGW03L SPECIFIC INSTALLATION REQUIREMENTS, TYPICAL FOR ALL...
X2 EXIT SIGN & EM LIGHT COMBO DUAL LITE UNIVERSAL 120-277V - - - - - PROVIDE ALL MOUNTING HARDWARE/ACCESSORIES AS...
EVE U G W E I SPECIFIC INSTALLATION REQUIREMENTS, TYPICAL FOR ALL...
X1 EXIT SIGN DUAL LITE UNIVERSAL 120-277V - - - - - PROVIDE ALL MOUNTING HARDWARE/ACCESSORIES AS...
HS71003-125
H7 WALL SCONCE HOMESTYLE LIGHTING WALL 120V 14 3000K - - - WET LISTED, INSTALL 14W A19 LED LAMP
FVS8 M 4 2 LO OS1
H5 4' LINEAR SURFACE LED FAIL-SAFE WALL 120-277V 45.5 3000K 80+ 5675 -
FVS4W M 2 1 LO 30 P187 WALL
H4 2' LINEAR SURFACE LED FAIL-SAFE SURFACE 120-277V 12.3 3000K 80+ 1230 -
FVS4 M 2 1 LO 30 P187 CEILING
H3 2' LINEAR SURFACE LED FAIL-SAFE SURFACE 120-277V 12.3 3000K 80+ 1230 -
FSV8 M 2 LD4 2 STD 30 P187 CEILING
H2 2' LINEAR SURFACE LED FAIL-SAFE SURFACE 120-277V 33.5 3000K 80+ 3718 -
SLD606 8 30 WH
H1 6" LED DOWNLIGHT HALO RECESSED 120-277V 12.2 3000K 80 760 0-10V, 5%
CATALOG NUMBER
TYPE DESCRIPTION MANUFACTURER & MOUNTING VOLTAGE WATTAGE CCT CRI LUMENS DIMMING REMARKS
HOUSE LUMINAIRE SCHEDULE
G3/3/2023
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E605
ELECTRICAL
LOAD
CALCULATIONS
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
***Unit Panel Rating 225A at 120/208V, 1Ø, 3W***
Minimum Service Ampacity at 120/208V, 1Ø, 3W:207
*-Table 220.42 (First 3000VA @ 100%, remainder @ 35%)
Net Calculated Load:42958
Sub-Total: 34819
(1) VTAC Unit 13977 13977
25% Largest Motor 174
(1) Domestic Circ. Pump 168 168
(1) Electric Water Heater @ 125% 6000 7500
(1) Clothes Dryer (Table 220.54) 5000 5000
(1) Electric Oven/Cooktop (Table 220.55) 8000 8000
Equipment
Sub-Total: 3498
(1) Refrigerator 950 712.5
(1) Microwave 1650 1237.5
(1) Dishwasher 1200 900
(1) Garbage Disposal 864 648
Fixed Appliances (220.53)
Demand*: 4641
Sub-Total: 7689
(1) Laundry Circuits, 1500W (220.52(B))1500
(2) Small Appliance Circuits, 1500W (220.52(A)) 3000
1063 Sq. Ft. @ 3VA 3189
General Lighting Load @ 3VA/Sq. Ft. 220.14 (J)NEC 220.42
Basic*
New Single Family Dwelling - 2BR-Largest Unit Main Panel
Description of Load
2020 NEC 220
RESIDENTIAL ELECTRICAL LOAD CALCULATION
Haymeadow - 2BR-Type1 Unit (Largest)
***Main Distribution Panel Rating 1600A at 120/208V, 3Ø, 4W***
Minimum Service Ampacity at 120/208V, 3Ø, 4W:1259
* First 3kW @ 100%, remainder up to 120kW @ 35%, above 120kW @ 25% - Table 220.42
Net Calculated Load: 453673
House Loads 36000
Sub-Total: 74460
(6) Misc. Garage Loads 226 1356
(6) Garage Door Openers 864 5184
(6) Electric Unit Heaters 3000 18000
(6) EV Charging Stations @ 125% 8320 49920
Garage Panels
Sub-Total: 274757
(9) VTAC-2 Units 13977 125793
(2) VTAC-1 Units 10046 20092
25% Largest Motor 174
(11) Domestic Circ. Pump 168 1848
(8) Electric Water Heater EWH-2 6000 60000
(3) Electric Water Heater EWH-1 4000 15000
(11) Electric Clothes Dryer (Table 220.54) 5000 25850
(11) Electric Range/Oven (Table 220.55) 8000 26000
Equipment
Sub-Total: 38478
(11) Refrigerator 950 7838
(11) Microwave 1650 13612.5
(11) Dishwasher 1200 9900
(11) Garbage Disposal 864 7128
Fixed Appliances (220.53)
Demand*: 29978
Sub-Total: 80079
(11) Laundry Circuits, 1500W (220.52(B))16500
(22) Small Appliance Circuits, 1500W (220.52(A))33000
10193 Sq. Ft. @ 3VA 30579
General Lighting Load @ 3VA/Sq. Ft. NEC 220.14 (J)NEC 220.42
Basic*
Total Unit SF: 10193
(4) 2BR-Type4 Unit 906 SF 3624
(4) 2BR-Type5 Unit 1063 SF 4252
(1) 2BR-Type6 Unit 1063 SF 1063
(1) 1BR-Type2 Unit 580 SF 580
(1) 1BR-Type1 Unit 674 SF 674
Unit SF Breakdown Area, SF
Building (11 Units)
Description of Load
2020 NEC 220
RESIDENTIAL ELECTRICAL LOAD CALCULATION
Haymeadow - 11 Unit Building
Ampacity at 120/208V, 3Ø, 4W:2473
* First 3kW @ 100%, remainder up to 120kW @ 35%, above 120kW @ 25% - Table 220.42
Net Calculated Load (VA): 890751
(2) House Panel 36000 72000
House Loads
Sub-Total: 148920
(12) Misc. Garage Loads 226 2712
(12) Electric Unit Heaters 3000 36000
(12) Garage Door Openers 864 10368
(12) EV Charging Stations @ 125% 6656 99840
Garage Panels
Sub-Total: 538885
(18) VTAC-2 Units 13977 251586
(4) VTAC-1 Units 10046 40184
25% Largest Motor 1819
(22) Domestic Circ Pump 168 3696
(22) Electric Water Heater 6000 165000
(22) Electric Clothes Dryer (Table 220.54) 5000 39600
(22) Electric Range/Oven (Table 220.55) 8000 37000
Equipment
Sub-Total: 76956
(22) Refrigerator 950 15675
(22) Microwave 1650 27225
(22) Dishwasher 1200 19800
(22) Garbage Disposal 864 14256
Fixed Appliances (220.53)
Demand*: 53990
Sub-Total: 160158
(22) Laundry Circuits, 1500W (220.52(B))33000
(44) Small Appliance Circuits, 1500W (220.52(A))66000
20386 Sq. Ft. @ 3VA 61158
General Lighting Load @ 3VA/Sq. Ft. NEC 220.14 (J)NEC 220.42
Basic*
Total Unit SF: 20386
(8) 2BR-Type6 Unit 906 SF 7248
(8) 2BR-Type5 Unit 1063 SF 8504
(2) 2BR-Type6 Unit 1063 SF 2126
(2) 1BR-Type2 Unit 580 SF 1160
(2) 1BR-Type1 Unit 674 SF 1348
Unit SF Breakdown Area,...
Electrical Load for Electrical Service (Bldgs A, B)
Description of Load
2020 NEC 220
RESIDENTIAL ELECTRICAL LOAD CALCULATION
Haymeadow - Electrical Service (Bldgs A, B)
Ampacity at 120/208V, 3Ø, 4W:2473
* First 3kW @ 100%, remainder up to 120kW @ 35%, above 120kW @ 25% - Table 220.42
Net Calculated Load (VA): 890751
(2) House Panel 36000 72000
House Loads
Sub-Total: 148920
(12) Misc. Garage Loads 226 2712
(12) Electric Unit Heaters 3000 36000
(12) Garage Door Openers 864 10368
(12) EV Charging Stations @ 125% 6656 99840
Garage Panels
Sub-Total: 538885
(18) VTAC-2 Units 13977 251586
(4) VTAC-1 Units 10046 40184
25% Largest Motor 1819
(22) Domestic Circ Pump 168 3696
(22) Electric Water Heater 6000 165000
(22) Electric Clothes Dryer (Table 220.54) 5000 39600
(22) Electric Range/Oven (Table 220.55) 8000 37000
Equipment
Sub-Total: 76956
(22) Refrigerator 950 15675
(22) Microwave 1650 27225
(22) Dishwasher 1200 19800
(22) Garbage Disposal 864 14256
Fixed Appliances (220.53)
Demand*: 53990
Sub-Total: 160158
(22) Laundry Circuits, 1500W (220.52(B))33000
(44) Small Appliance Circuits, 1500W (220.52(A))66000
20386 Sq. Ft. @ 3VA 61158
General Lighting Load @ 3VA/Sq. Ft. NEC 220.14 (J)NEC 220.42
Basic*
Total Unit SF: 20386
(8) 2BR-Type6 Unit 906 SF 7248
(8) 2BR-Type5 Unit 1063 SF 8504
(2) 2BR-Type6 Unit 1063 SF 2126
(2) 1BR-Type2 Unit 580 SF 1160
(2) 1BR-Type1 Unit 674 SF 1348
Unit SF Breakdown Area,...
Electrical Load for Electrical Service (Bldgs F, G)
Description of Load
2020 NEC 220
RESIDENTIAL ELECTRICAL LOAD CALCULATION
Haymeadow - Electrical Service (Bldgs F, G)
2
2 VE CHANGES 03/03/23G3/3/2023
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E606
ELECTRICAL
PANEL
SCHEDULES
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING A91 MT. HOPE CIRCLEEAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
PANEL:TYPICAL GARAGE PANEL G*
ISSUE DATE:11.14.2022 FEEDER DEMAND AMPS 50.7
BY:CT FEEDER DEMAND KVA 12.2
2. CONTROL WIRING FOR HVAC EQUIPMENT BY MECHANICAL CONTRACTOR - NIC CONN.KVA (CODE 4)0.0
TIMECLOCK OFF OPERATION.CONN.KVA (CODE 3)0.2
1. ROUTE EXTERIOR LIGHTS THROUGH PHOTOCELL/TIMECLOCK FOR PHOTOCELL ON/CONN.KVA (CODE 2)3.6
NOTES:CONN.KVA (CODE 1)6.7
TOTAL 5474 5008 CONNECTED KVA 10.5
19 20 1 SPARE ///////// 0 SPARE 1 20 20
17 20 1 SPARE 0 ///////// SPARE 1 20 18
15 20 1 SPARE ///////// 0 SPARE 1 20 16
13 20 1 SPARE 0 ///////// SPARE 1 20 14
11 20 1 SPARE ///////// 0 SPARE 1 20 12
9 20 1 SPARE 0 ///////// SPARE 1 20 10
7 20 1 SPARE ///////// 1500 1500 --- --- --- 2 8
5 2 20 1 DOOR OPENER 600 2100 ///////// 1500 EUH-2 2 20 2 6
3 3 20 1 RECEPTS 180 ///////// 3508 3328 --- --- --- 1 4
1 1 20 1 LIGHTING 46 3374 ///////// 3328 EV CHARGING STATION 2 40 1 2
NO. CODE TRIP POLE DESCRIPTION MISC REC LITE VA A B VA LITE REC MISC DESCRIPTION POLE TRIP CODE NO.
CKT CB LOAD DESIGNATION LOAD PHASES LOAD LOAD DESIGNATION CB CKT
AIC RATING:10,000 MAINS:MLO 4=(KITCHEN EQUIPMENT NEC 220.56)
PANEL:TYPICAL GARAGE PANEL G*BUS (AMPS):100 3=(RECEPTACLES NEC 220.44)
JOB:Haymeadow PHASE & WIRE:1PH 3W 2=(NON-CONTINUOUS LOAD NEC 220.14)
DATE:11/15/2022 PANEL VOLTAGE:120/240 CKT CODE: 1=(CONTINUOUS LOAD NEC 210.19(A)
MIN 20A CKTS 1.33
MIN 15A CKTS 1.77
AMPACITY: 26.58
LOAD @3VA/SF: 3189
UNIT SF: 1063 (Largest Unit, Worst-case Typical)
Minimum Number Branch Circuits Required
PANEL:Typical Dwelling Unit (2BR)
ISSUE DATE:3.3.23 FEEDER DEMAND AMPS See Dwelling Unit Load Calculations
BY:CT FEEDER DEMAND KVA
BASED ON SQUARE D HOMELINE LOADCENTER 3-TIER SERIES RATED SYSTEM - LABEL PER NEC 240.86B
PROVIDE ALL CIRCUIT BREAKERS AS APPROVED BY THE AHJ.
** - PROVIDE 20A2P BREAKER FOR UNITS WITH EWH-1 (4000W), 2BR TYPE 6
* - PROVIDE GFCI DEVICES IN KITCHEN PER NEC 210.8(A)(6 AND NEC 406.11 REQUIREMENTS responsible to perform all work in accordance with 2020 NEC requirements.
GFCI - GROUND-FAULT CIRCUIT INTERRUPTER PER NEC 210.8(A)(1). (MAY BE LOCAL GFCI DEVICES)with 2020 NEC 210 and NEC 210.52 requirements. Contractor shall be
AFCI - ARC-FAULT CIRCUIT INTERRUPTER CIRCUIT BREAKER PER 2017 NEC 210.12(B)Note: All branch circuiting and devices installed shall be in compliance
NOTES:>>ALL DEVICES INSTALLED SHALL COMPLY WITH 2017 NEC 406.11 REQUIREMENTS<<See Dwelling Unit Load Calculations
TOTAL 22035 23396 CONNECTED KVA 45.4
29 AFCI 15 1 SPARE 0 ///////// SPARE 1 15 AFCI 30
27 AFCI 15 1 SPARE ///////// 3000 3000 --- --- --- 28
25 AFCI 15 1 SPARE 3000 ///////// 3000 EWH-2 2 30 **26
23 --- --- (FUTURE)///////// 4503 4503 --- --- --- AFCI 24
21 100 2 PV SYSTEM CONNECTION 4503 ///////// 4503 1 VTAC UNIT (HEATER CKT) 2 45 AFCI 22
19 AFCI 15 1 SPARE ///////// 2486 2486 --- --- --- 20
17 AFCI 15 1 SPARE 2486 ///////// 2486 1 VTAC UNIT 2 35 18
15 15 1 DCP-1 168 ///////// 4168 4000 PROVIDE 4-WIRE CONNECTION --- ---16
13 AFCI 15 1 REFRIGERATOR 1 696 4696 ///////// 4000 1 ELEC RANGE OVEN 2 50 14
11 AFCI 20 1 MICROWAVE 1 1800 ///////// 4300 2500 PROVIDE 4-WIRE CONNECTION --- --- 12
9 *20 1 SMALL APPLIANCE 2 1500 4000 ///////// 2500 1 CLOTHES DRYER 2 30 10
7 *20 1 SMALL APPLIANCE 2 1500 ///////// 3000 1500 1 LAUNDRY CIRCUIT 1 20 GFCI 8
5 AFCI 15 1 GENERAL LIGHTING 1075 2275 ///////// 1200 1 DISHWASHER 1 20 GFCI 6
3 AFCI 15 1 GENERAL LIGHTING 1075 ///////// 1939 864 1 GARBAGE DISPOSAL 1 20 GFCI 4
1 AFCI 15 1 GENERAL LIGHTING 1075 1075 ///////// 1 BATHROOM CIRCUIT 1 20 GFCI 2
NO. CODE TRIP POLE DESCRIPTION MISC REC LITE VA A B VA LITE REC MISC DESCRIPTION POLE TRIP CODE NO.
CKT CB LOAD DESIGNATION LOAD PHASES LOAD LOAD DESIGNATION CB CKT
AIC RATING:22,000 MAINS:MLO ** - COMPLY WITH NEC 210.7(B) REQUIREMENTS
PANEL:Typical Dwelling Unit (2BR)BUS (AMPS):125 * - GFCI DEVICES PER 210.8(B)(6) & NEC 406.11
JOB:Haymeadow PHASE & WIRE:1PH 3W GFCI= SEE NOTES BELOW
DATE:3/3/2023 PANEL...120/208 CKT CODE: AFCI= SEE NOTES BELOW
REMAINDER IN EXCESS OF 10KVA+ALLOWABLE DEMAND FOR COMMERCIAL COOKING EQUIPMENT (IF APPLICABLE) PER NEC 220.56 REQUIREMENTS.
* - FEEDER DEMAND KVA INDICATED IS THE SUM OF CONN.KVA (CODE 1)X125%+100% OF CONN.KVA (CODE 2)+100% OF FIRST 10KVA OF GENERAL-USE RECEPTACLES PER NEC 220.44 AND 50% OF
PANEL:HP
ISSUE DATE:6.13.22 FEEDER DEMAND AMPS 88.0
BY:CT FEEDER DEMAND KVA*31.7
CONN.KVA (CODE 4)0.0 NEC 220.56
CONN.KVA (CODE 3)2.2 NEC 220.44
CONN.KVA (CODE 2)19.8 100
NOTES:98.7 85.1 49.6 CONN.KVA (CODE 1 )7.8 125
TOTAL 11849 10216 5953 CONNECTED KVA 28.0 DEMAND %/NEC REF.
41 20 1 SPARE ///////// ///////// 0 SPARE 1 20 42
39 20 1 SPARE ///////// 0 ///////// SPARE 1 20 40
37 20 1 SPARE 0 ///////// ///////// SPARE 1 20 38
35 20 1 SPARE ///////// ///////// 0 SPARE 1 20 36
33 20 1 SPARE ///////// 0 ///////// SPARE 1 20 34
31 1 --- --- ---375 1875 ///////// ///////// 1500 --- --- --- 2 32
29 1 20 2 LTG - SITE 375 ///////// ///////// 1875 1500 EUH-3 - LVL 1 STAIRWELL 2 20 2 30
27 1 --- --- ---3328 ///////// 4828 ///////// 1500 --- --- --- 2 28
25 1 40 2 EV Charging Station 3328 4828 ///////// /////////1500 EUH-3 - LVL 1 CORRIDOR 2 20 2 26
23 20 1 SPARE ///////// ///////// 1000 1000 --- --- --- 2 24
21 3 20 1 Recepts - Exterior 360 ///////// 1360 ///////// 1000 EUH-1 - ROOM 160 2 20 2 22
19 20 1 SPARE 1000 ///////// ///////// 1000 --- --- --- 2 20
17 3 20 1 Rcpts - Lev 2,3 corr 720 ///////// ///////// 1000 EUH-1 - ROOM 169 2 20 2 18
15 2 20 1 Fire Alarm Circuit 500 ///////// 1500 ///////// 1000 --- --- --- 2 16
13 3 20 1 Rcpts - Lev 1 W corr,stor,mech 540 1540 ///////// ///////// 1000 EUH-1 - ROOM 167 2 20 2 14
11 3 20 1 Rcpts - Lev 1 E corr,stor,mech 540 ///////// ///////// 568 28 LTG - EXTERIOR, BLDG MNTD 1 20 1 12
9 20 1 SPARE ///////// 0 ///////// SPARE 1 20 10
7 1 20 1 Lights-Utility-Storage Level 1 E. 72 72 ////////////////// SPARE 1 20 8
5 1 20 1 Lights-Utility-Storage Level 1 W. 84 ///////// ///////// 2510 2426 -- -- -- 2 6
3 1 20 1 Lights- Level 1,2,3 stairs 102 ///////// 2528 ///////// 2426 -- -- -- 2 4
1 1 20 1 Lights- Level 1,2,3 corridor 108 2534 ///////// ///////// 2426 DBP-1 - ROOM 167 3 30 2 2
NO. CODE TRIP POLE DESCRIPTION MISC REC LITE VA A B C VA LITE REC MISC DESCRIPTION POLE TRIP CODE NO.
CKT CB LOAD DESIGNATION LOAD PHASES LOAD LOAD DESIGNATION CB CKT
AIC RATING:42,000 MAINS:200/3 4=(KITCHEN EQUIPMENT NEC 220.56)
PANEL:HP BUS (AMPS):200 3=(RECEPTACLES NEC 220.44)
JOB:Haymeadow PHASE AND WIRE:3PH,4W 2=(NON-CONTINUOUS LOAD NEC 220.14)
DATE:3/3/2023 PANEL VOLTAGE:208/120V CKT CODE: 1=(CONTINUOUS LOAD NEC 210.19(A)
NOTE: CONDUCTORS SHOWN ARE COPPER UNLESS NOTED OTHERWISE.
DBP-1 BOOSTER PUMP 30A3P 20.2 7,277 208 3 30A3P W/30A FUSES (3#10;#10GND) 3/4"C
DCP-1 DOMESTIC RECIRC. PUMP 15A1P 1.4 168 120 1 MOTOR RATED SWITCH (2#12;#12GND) 3/4"C
EUH-2 & 3 ELECTRIC UNIT HEATER 20A2P 14.4 3,000 208 1 - (3#12;#12GND) 3/4"C DISCONNECT IS INCLUDED WITH UNIT
EUH-1 ELECTRIC UNIT HEATER 20A2P 9.6 2,000 208 1 - (3#12;#12GND) 3/4"C DISCONNECT IS INCLUDED WITH UNIT
VTAC-2 CKT 2 VERTICAL TERMINAL HEAT PUMP (HEATING CKT) 45A2P 43.3 9,006 208 1 60A2P FUSED DISC. (3#6;#10GND) 3/4"C FUSE PER MANUFACTURER REQUIREMENTS.
VTAC-2 CKT 1 VERTICAL TERMINAL HEAT PUMP 35A2P 23.9 4,971 208 1 60A2P FUSED DISC. (3#8;#10GND) 3/4"C FUSE PER MANUFACTURER REQUIREMENTS.
VTAC-1 VERTICAL TERMINAL HEAT PUMP 50A2P 48.3 10,046 208 1 60A2P FUSED DISC. (3#6;#10GND) 3/4"C FUSE PER MANUFACTURER REQUIREMENTS.
EF-1 EXHAUST FAN 20A1P 0.1 8 120 1 MOTOR RATED SWITCH (2#12;#12GND) 3/4"C
KEY ITEM CB AMPS WATTS VOLT PH. DISCONNECT FEEDER NOTES
EQUIPMENT SCHEDULE
MIN 20A CKTS 0.84
MIN 15A CKTS 1.12
AMPACITY: 16.85
LOAD @3VA/SF: 2022
UNIT SF: 674 (Largest Unit, Worst-case Typical)
Minimum Number Branch Circuits Required
PANEL:Typical Dwelling Unit (1BR)
ISSUE DATE:3.3.23 FEEDER DEMAND AMPS See Dwelling Unit Load Calculations
BY:CT FEEDER DEMAND KVA
BASED ON SQUARE D HOMELINE LOADCENTER 3-TIER SERIES RATED SYSTEM - LABEL PER NEC 240.86B
PROVIDE ALL CIRCUIT BREAKERS AS APPROVED BY THE AHJ.
* - PROVIDE GFCI DEVICES IN KITCHEN PER NEC 210.8(A)(6 AND NEC 406.11 REQUIREMENTS responsible to perform all work in accordance with 2020 NEC requirements.
GFCI - GROUND-FAULT CIRCUIT INTERRUPTER PER NEC 210.8(A)(1). (MAY BE LOCAL GFCI DEVICES)with 2020 NEC 210 and NEC 210.52 requirements. Contractor shall be
AFCI - ARC-FAULT CIRCUIT INTERRUPTER CIRCUIT BREAKER PER 2017 NEC 210.12(B)Note: All branch circuiting and devices installed shall be in compliance
NOTES:>>ALL DEVICES INSTALLED SHALL COMPLY WITH 2017 NEC 406.11 REQUIREMENTS<<See Dwelling Unit Load Calculations
TOTAL 21871 24083 CONNECTED KVA 46.0
29 AFCI 15 1 SPARE 0 ///////// SPARE 1 15 AFCI 30
27 AFCI 15 1 SPARE ///////// 2000 2000 --- --- --- 28
25 AFCI 15 1 SPARE 2000 ///////// 2000 EWH-1 2 20 26
23 --- --- (FUTURE)///////// 4503 4503 SPARE --- --- AFCI 24
21 100 2 PV SYSTEM CONNECTION 4503 ///////// 4503 1 SPARE 2 45 AFCI 22
19 AFCI 15 1 SPARE ///////// 5023 5023 --- --- --- 20
17 AFCI 15 1 SPARE 5023 ///////// 5023 1 VTAC UNIT 2 50 18
15 15 1 DCP-1 168 ///////// 4168 4000 PROVIDE 4-WIRE CONNECTION --- ---16
13 AFCI 15 1 REFRIGERATOR 1 696 4696 ///////// 4000 1 ELEC RANGE OVEN 2 50 14
11 AFCI 20 1 MICROWAVE 1 1800 ///////// 4300 2500 PROVIDE 4-WIRE CONNECTION --- --- 12
9 *20 1 SMALL APPLIANCE 2 1500 4000 ///////// 2500 1 CLOTHES DRYER 2 30 10
7 *20 1 SMALL APPLIANCE 2 1500 ///////// 3000 1500 1 LAUNDRY CIRCUIT 1 20 GFCI 8
5 AFCI 15 1 GENERAL LIGHTING 225 1425 ///////// 1200 1 DISHWASHER 1 20 GFCI 6
3 AFCI 15 1 GENERAL LIGHTING 225 ///////// 1089 864 1 GARBAGE DISPOSAL 1 20 GFCI 4
1 AFCI 15 1 GENERAL LIGHTING 225 225 ///////// 1 BATHROOM CIRCUIT 1 20 GFCI 2
NO. CODE TRIP POLE DESCRIPTION MISC REC LITE VA A B VA LITE REC MISC DESCRIPTION POLE TRIP CODE NO.
CKT CB LOAD DESIGNATION LOAD PHASES LOAD LOAD DESIGNATION CB CKT
AIC RATING:22,000 MAINS:MLO ** - COMPLY WITH NEC 210.7(B) REQUIREMENTS
PANEL:Typical Dwelling Unit (1BR)BUS (AMPS):125 * - GFCI DEVICES PER 210.8(B)(6) & NEC 406.11
JOB:Haymeadow PHASE & WIRE:1PH 3W GFCI= SEE NOTES BELOW
DATE:3/3/2023 PANEL...120/208 CKT CODE: AFCI= SEE NOTES BELOW
2
2 VE CHANGES 03/03/23G3/3/2023