Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout21234_Haymeadow_BLDG E_PERMIT RESUBMITTAL_ELEC_2023-03-03_StampedABBREVIATIONS
DUPLEX RECEPTACLE, MOUNTED +18" O.C. UNO
AC = MOUNTED +8" O.C. ABOVE COUNTER EWC = GFI RECEPTACLE FOR WATER COOLER
GFI = GROUND FAULT CIRCUIT INTERRUPTER T = TAMPER RESISTANT PER NEC 406.12(A)
WP = GFCI WITH WEATHERPROOF IN-USE COVER PER NEC 406.9(B)(1)
DUPLEX RECEPTACLE LISTED FOR USE IN COUNTERTOPS, PROTECTED BY UPSTREAM GFCI
DUPLEX RECEPTACLE, FLUSH MOUNTED IN FLOOR BOX
QUADRUPLEX RECEPTACLE, MOUNTED +18" O.C. UNO
AC = MOUNTED +8" O.C. ABOVE COUNTER GFCI = GROUND FAULT CIRCUIT INTERRUPTER
T = TAMPER RESISTANT PER NEC 406.12 WP = GFCI WITH WEATHERPROOF IN-USE COVER
QUADRUPLEX RECEPTACLE, FLUSH MOUNTED IN FLOOR BOX
SPECIAL RECEPTACLE, COORDINATE INSTALLATION WITH EQUIPMENT SUPPLIED
ED = ELECTRIC DRYER, PROVIDE 208V/1, 30A-2P 4-WIRE CONNECTION.
ER = ELECTRIC RANGE, PROVIDE 208V/1, 50A-2P 4-WIRE CONNECTION.
COUNTER-MOUNTED AIR SWITCH FOR GARBAGE DISPOSAL. COORDINATE WITH MILLWORK VENDOR.
MOTOR CONNECTION, COORDINATE INSTALLATION WITH EQUIPMENT SUPPLIED
G = GARAGE DOOR MOTOR ASSEMBLY WITH INTEGRAL LIGHTING COMPONENT
JUNCTION BOX SIZE PER NEC 314, PROVIDE COVER PLATE TO CONCEAL WIRING WITHIN
PANELBOARD
ELECTRICAL BRANCH CIRCUIT -PROTECTED PER NEC 240.4(D) REQUIREMENTS
DISCONNECT SWITCH (F = FUSIBLE)
UTILITY COMPANY METER
ELECTRICAL SYMBOL LIST
A AMP
AC ABOVE COUNTER
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFI ARC FAULT INTERRUPTER
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
AIC AMPS INTERRUPTING CAPACITY
AL ALUMINUM
AWG AMERICAN WIRE GAUGE
AV AUDIO/VISUAL
BLDG BUILDING
C CONDUIT
CATV CABLE TELEVISION SYSTEM
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CL CENTERLINE
CU COPPER
DWG DRAWING
(E)EXISTING
EF EXHAUST FAN
EMT ELECTRIC METALLIC TUBING
EM EMERGENCY
EPO EMERGENCY POWER OFF
FLA FULL LOAD AMPS
GD GARBAGE DISPOSAL
GR GROUND
GC GENERAL CONTRACTOR
GFI/GFCI GROUND FAULT CIRCUIT INTERRUPTER
HACR HACR (HEATING, AC & REFRIGERATION) RATED
HP HORSE POWER
IG ISOLATED GROUND
IP INTERNET PROTOCOL
JB JUNCTION BOX
KCMIL 1000 CIRCULAR MILS
KV KILOVOLT
KVA KILOVOLT AMPERES
KW KILOWATT
KWH KILOWATT HOUR
LAN LOCAL AREA NETWORK
LCP LIGHTING CONTROL PANEL
LRA LOCKED ROTOR AMPS
LSIGA L(LONG)
S (SHORT)
I (INSTANTANEOUS)
G (GROUND FAULT)
A (ARC ENERGY REDUCTION)
LTFC LIQUID TIGHT FLEXIBLE CONDUIT
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MLO MAIN LUG ONLY
MSB MAIN SWITCH BOARD
(N)NEW
N.C.NORMALLY CLOSED
N.O.NORMALLY OPEN
NF NON-FUSED
NL NIGHT LIGHT
NIC NOT IN CONTRACT
P POLE
PC PLUMBING CONTRACTOR
PH PHASE
PPE PERSONAL PROTECTION EQUIPMENT
PVC POLYVINYL CHLORIDE CONDUIT
QTY QUANTITY
RCP REFLECTED CEILING PLAN
RLA RUNNING LOAD AMPS
RMC RIGID METAL CONDUIT
RNC RIGID NON-METALLIC CONDUIT
SPDT SINGLE POLE, DOUBLE THROW
SPST SINGLE POLE, SINGLE THROW
ST SHUNT TRIP
TL TWISTLOCK
TR TAMPER RESISTANT
TYP TYPICAL
UL UNDERWRITERS LABORATORIES, INC.
UNO UNLESS NOTED OTHERWISE
USP UNINTERRUPTIBLE POWER SUPPLY
V VOLT
W WIRE
WP WEATHER PROOF
WPI WEATHER PROTECTED IN-USE
XFMR TRANSFORMER
XP EXPOSION PROOF
LABELING REQUIREMENTS
ALL ELECTRICAL LABELS SHALL COMPLY WITH LATEST NATIONAL ELECTRICAL CODE REQUIREMENTS.
GENERAL LABELING REQUIREMENTS NOTED BELOW MAY NOT BE COMPLETE OR COVER ALL INSTALLATIONS.
WIRING DEVICES:
PANEL NAME -CIRCUIT NAME
PROVIDE BLACK LETTERING ON CLEAR LABEL FOR NORMAL CIRCUITS AND RED LETTERING ON CLEAR LABEL
FOR EMERGENCY/STANDBY CIRCUITS.
STARTERS / DISCONNECTS / VFDs:
EQUIPMENT ID
VOLTAGE / PHASE / WIRES
INDICATE FUSE SIZE, IF APPLICABLE
FED FROM CIRCUIT NAME
FEEDING TO CIRCUIT NAME
ARC FLASH LABELS PER NFPA-70E & NEC INDICATING:
1. DANGER OR WARNING HEADER
2. INCIDENT ENERGY
3. MINIMUM ARC RATING
4. ARC FLASH BOUNDARY
5. PERSONAL PROTECTIVE EQUIPMENT (PPE)
6. LIMITED APPROACH
7. RESTRICTED APPROACH
8. SHOCK RISK
9. DATE LABEL WAS APPLIED
SWITCHBOARDS, TRANSFORMERS, HARMONIC FILTERS, ELECTRICAL PANELS:
EQUIPMENT NAME
EQUIPMENT RATING
FED FROM XXXX
VOLTAGE / PHASE / AMPS
PRIMARY DISCONNECT LOCATION AND NAME, WHERE APPLICABLE
COLORED -CONDUITS AND JUNCTION BOX REQUIREMENTS:
RED-COLORED -FIRE ALARM
BLUE-COLORED -TEMPERATURE CONTROLS
MAXIMUM AVAILABLE FAULT CURRENT:
SERVICE EQUIPMENT SHALL BE LEGIBLY MARKED IN THE FIELD WITH THE MAXIMUM AVAILABLE FAULT
CURRENT. THE FIELD MARKING SHALL INCLUDE THE DATE. THE FAULT CURRENT CALCULATION WAS
PERFORMED AND BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED.
POWER
M
F
J
LIGHTING
ROUND LUMINAIRE (HALF SHADE = UNSWITCHED) -REFER TO LUMINAIRE SCHEDULE
ROUND EMERGENCY DOWNLIGHT -REFER TO LUMINAIRE SCHEDULE
WALL MOUNTED LUMINAIRE -REFER TO LUMINAIRE SCHEDULE
TRACK LIGHTING (# OF HEADS SHOWN) -REFER TO LUMINAIRE SCHEDULE
LINEAR FLUORESCENT LUMINAIRE -REFER TO LUMINAIRE SCHEDULE
LINEAR FLUORESCENT EMERGENCY LUMINAIRE -REFER TO LUMINAIRE SCHEDULE
EXIT SIGN -CEILING MOUNTED (SHADE = FACE, ARROW = DIRECTION), CONNECT AHEAD OF LIGHT
SWITCH -REFER TO LUMINAIRE SCHEDULE
EXIT SIGN -BACK MOUNTED (SHADE = FACE, ARROW = DIRECTION), CONNECT AHEAD OF LIGHT
SWITCH -REFER TO LUMINAIRE SCHEDULE
POLE MOUNTED LUMINAIRE (CIRCLE INDICATES POLE, BOXES INDICATE HEADS) -REFER TO
LUMINAIRE SCHEDULE
TOGGLE SWITCH, MOUNTED +48" O.C. UNO
2 = TWO POLE 3 = THREE WAY
4 = FOUR WAY D = DIMMER (SIZED TO MATCH LOAD SERVED)
K = KEYED SWITCH M = MOMENTARY CONTACT SWITCH
OC = OCC. SENSOR SWITCH DR = DOOR ACTIVATED
P = SWITCH WITH PILOT LIGHT T = TIMER
LV = LOW VOLTAGE CB = CIRCUIT BREAKER
OCCUPANCY SENSOR -CEILING MOUNTED, DUAL TECHNOLOGY
COMMUNICATIONS
DUPLEX DATA RECEPTACLE, MOUNTED +18" O.C. UNO AC = MOUNTED +8" O.C. ABOVE COUNTER
DUPLEX DATA RECEPTACLE, FLUSH MOUNTED IN FLOOR BOX
SIMPLEX TELEPHONE RECEPTACLE, MOUNTED +18" O.C. UNO
AC = MOUNTED +8" O.C. ABOVE COUNTER
W = MOUNTED +54" O.C. ABOVE FINISHED FLOOR FOR WALL MOUNTING PHONE
COMBINATION TEL/DATA RECEPTACLE, FLUSH MOUNTED IN FLOOR BOX --
PROVIDE (1) DATA AND (1) TELEPHONE JACK UNO
CABLE TELEVISION OUTLET, COORDINATE MOUNTING HEIGHT WITH OWNER
CATV OUTLET. PROVIDE BACKBOX, COAX/CAT 5 CABLE, DEVICE JACK AS DIRECTED BY OWNERS
AUTHORIZED REPRESENTATIVE. REFER TO PLANS FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
OS
TV
FIRE ALARM SYSTEM
1. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE.
2. CONTRACTOR SHALL ENSURE THAT ALL MOUNTING HEIGHTS COMPLY WITH CURRENT ADA REQUIREMENTS.
3. WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING
LINE OR +12" ABOVE TOP OF DOOR TRIM WHERE DISTANCE TO CEILING IS GREATER THAN 24".
4. ALL ABOVE COUNTER (DESIGNATED BY "AC") SHALL BE MOUNTED 8" ABOVE COUNTER OR MAXIMUM HEIGHT OF 44" TO TOP OF DEVICE.
VERIFY HEIGHTS WITH ARCHITECT.
5. FOR CEILINGS BELOW 7'-4", FIRE ALARM STROBE OR HORN/STROBES SHALL BE WALL MOUNTED 6" BELOW FINISHED CEILING.
6. IN LOCATIONS WHERE SIMILAR DEVICES ARE MOUNTED AT THE SAME HEIGHT, DEVICES SHALL BE PROPERLY "GANGED" AND SHALL
HAVE A SINGLE COVERPLATE.
7. IN LOCATIONS WHERE DIFFERENT DEVICES ARE MOUNTED AT DIFFERENT HEIGHTS WITHIN FOUR FEET OF ONE ANOTHER, DEVICES
SHALL BE MOUNTED SUCH THAT THEY HAVE A COMMON CENTERLINE. IF THERE ARE THREE OR MORE DEVICES, THE CONTRACTOR
SHALL REQUEST A DETAIL FROM THE ARCHITECT.
NOTES:
FINISHED FLOOR18"RECEPTACLEDISCONNECT SWITCHTHE CENTER OF THE OPERATING HANDLE OF THE
SWITCH OR CIRCUIT BREAKER CANNOT BE MORE
THAN 6'-7" ABOVE THE FLOOR OR PLATFORM
WHEN IT IS IN ITS HIGHEST POSITIONPANELBOARDEQUIPMENT POWER FEEDVARIESJ
DEVICE MOUNTING REQUIREMENTS
FINISHED FLOOREXTERIOR LIGHTDOOR 12"DOOR 12"EXIT
48"MANUAL WALL MOUNTED LIGHTING CONTROLSFINISHED FLOORDOOR CONTACTDOOR
VARIESFIRE ALARM DEVICESCOORDINATED W/ ACCESS CONTROLVENDOR18"DATA OUTLETH
MOUNTING REQUIREMENTS MUST BE
COORDINATED WITH FIRE ALARM DESIGNER
F
S
S
S
UL LISTED COMBINATION CARBON MONOXIDE/SMOKE ALARM PER IFC 908.7.4.1-PROVIDE
HARDWIRED 120V POWER AND BACK-UP BATTERY POWER. WHERE MORE THAN ONE ALARM IS
LOCATED IN A SINGLE DWELLING UNIT, LINK OPERATION IN ACCORDANCE WITH 101-9.6.2.9.3.
PROVIDE SYSTEM DETECTORS FOR NON-DWELLING UNIT AREA PROTECTION PER LIFE SAFETY
SYSTEM DESIGN BY OTHERS -REFER TO GENERAL NOTE 24 THIS SHEET.
FIRE ALARM - HORN
FIRE ALARM - STROBE
FIRE ALARM - HORN AND STROBE
FIRE ALARM CONTROL PANEL
FIRE ALARM REMOTE ANNUNCIATOR PANEL
REMOTE TEST STATION
FACP
FAA
RTS
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E000
ELECTRICAL
LEGEND & NOTES
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
E3/3/2023
ELECTRICAL SPECIFICATIONS
ELECTRICAL SYSTEM COMMISSIONING REQUIREMENTS
GENERAL
COMPLETE SYSTEM COMMISSIONING IS TO BE PROVIDED BY CERTIFIED COMMISSIONING
AUTHORITY (CxA) INCLUDING ELECTRICAL POWER AND LIGHTING SYSTEMS PER IECC C408
REQUIREMENTS.
COMMISSIONING PLAN
THE CxA SHALL PROVIDE A COMMISSIONING PLAN INCLUDING THE FOLLOWING ITEMS:
1. A NARRATIVE DESCRIPTION OF THE ACTIVITIES THAT WILL BE ACCOMPLISHED DURING EACH
PHASE OF COMMISSIONING, INCLUDING THE PERSONNEL INTENDED TO ACCOMPLISH EACH OF THE
ACTIVITIES.
2. A LISTING OF THE SPECIFIC EQUIPMENT, APPLIANCES, OR SYSTEMS TO BE TESTED AND A
DESCRIPTION OF THE TESTS TO BE PERFORMED.
3. FUNCTIONS TO BE TESTED INCLUDING, BUT NOT LIMITED TO, CALIBRATIONS AND ECONOMIZER
CONTROLS.
4. CONDITIONS UNDER WHICH THE TEST WILL BE PERFORMED. TESTING SHALL AFFIRM WINTER
AND SUMMER DESIGN CONDITIONS AND FULL OUTSIDE AIR CONDITIONS.
5. MEASURABLE CRITERIA OF PERFORMANCE.
FUNCTIONAL TESTING
PRIOR TO PASSING FINAL INSPECTION, THE CxA SHALL PROVIDE EVIDENCE THAT THE LIGHTING
CONTROL SYSTEMS HAVE BEEN TESTED TO ENSURE THAT CONTROL HARDWARE AND SOFTWARE
ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER WORKING CONDITION IN
ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND
ANUFACTURER'S INSTRUCTIONS. FUNCTIONAL TESTING FOR THE APPLICABLE CONTROL TYPE
SHALL BE AS FOLOWS:
OCCUPANT SENSOR CONTROLS:WHERE OCCUPANT SENSOR CONTROLS ARE PROVIDED, THE
FOLLOWING PROCEDURES SHALL BE PERFORMED:
1. CERTIFY THAT THE OCCUPANT SENSOR HAS BEEN LOCATED AND AIMED IN ACCORDANCE WITH
MANUFACTURER RECOMMENDATIONS.
2. FOR PROJECTS WITH SEVEN OR FEWER OCCUPANT SENSORS, EACH SENSOR SHALL BE
TESTED.
3. FOR PROJECTS WITH MORE THAN SEVEN OCCUPANT SENSORS
OR OCCUPANT SENSOR CONTROLS TO BE TESTED, VERIFY THE FOLLOWING:
A. WHERE OCCUPANT SENSOR CONTROLS INCLUDE STATUS INDICATORS, VERIFY CORRECT
OPERATION.
B. THE CONTROLLED LIGHTS TURN OFF OR DOWN TO THE PERMITTED LEVEL WITHIN THE
REQUIRED TIME.
C. FOR AUTO-ON OCCUPANT SENSOR CONTROLS, THE LIGHTS TURN ON TO THE PERMITTED LEVEL
WHEN AN OCCUPANT ENTERS THE SPACE.
D. FOR MANUAL-ON OCCUPANT SENSOR CONTROLS, THE LIGHTS TURN ON ONLY WHEN
ANUALLY ACTIVATED.
E. THE LIGHTS ARE NOT INCORRECTLY TURNED ON BY MOVEMENT IN ADJACENT AREAS OR BY
HVAC OPERATION.
TIME-SWITCH CONTROLS
WHERE TIME-SWITCH CONTROLS ARE PROVIDED, THE FOLLOWING PROCEDURES SHALL BE
PERFORMED:
A. CONFIRM THAT THE TIME-SWITCH CONTROL IS PROGRAMMED WITH ACCURATE WEEKDAY,
WEEKEND, AND HOLIDAY SCHEDULES.
B. PROVIDE DOCUMENTATION TO THE OWNER OF TIME-SWITCH CONTROLS PROGRAMMING
INCLUDING WEEKDAY, WEEKEND, HOLIDAY SCHEDULES, AND SET-UP AND PREFERENCE PROGRAM
SETTINGS.
C. VERIFY THE CORRECT TIME AND DATE IN THE TIME SWITCH.
D. VERIFY THAT ANY BACK-UP EQUIPMENT IS INSTALLED AND ENERGIZED.
E. VERIFY THAT THE OVERRIDE TIME LIMIT IS SET TO NOT MORE THAN 2 HOURS.
F. SIMULATE OCCUPIED CONDITION. VERIFY AND DOCUMENT THE FOLLOWING:
a. ALL LIGHTS CAN BE TURNED ON AND OFF BY THE RESPECTIVE AREA CONTROL SWITCH.
b. THE SWITCH ONLY OPERATES LIGHTING IN THE ENCLOSED SPACE IN WHICH THE SWITCH IS
LOCATED.
G. SIMULATE UNOCCUPIED CONDITION. VERIFY AND DOCUMENT THE FOLLOWING:
a. NONEXEMPT LIGHTING TURNS OFF.
b. MANUAL OVERRIDE SWITCH ALLOWS ONLY THE LIGHTS IN THE ENCLOSED SPACE WHERE THE
OVERRIDE SWITCH IS LOCATED TO TURN ON UNTIL THE NEXT SCHEDULED SHUTOFF OCCURS.
H. ADDITIONAL TESTING AS SPECIFIED THE COMMISSIONING AGENT.
DAYLIGHT RESPONSIVE CONTROLS
WHERE DAYLIGHT RESPONSIVE CONTROLS ARE PROVIDED, THE FOLLOWING SHALL BE VERIFIED:
A. CONTROL DEVICES HAVE BEEN PROPERLY LOCATED, FIELD CALIBRATED AND SET FOR
ACCURATE SETPOINTS AND THRESHOLD LIGHT LEVELS.
B. DAYLIGHT CONTROLLED LIGHTING LOADS ADJUST TO LIGHT LEVEL SET POINTS IN RESPONSE TO
AVAILABLE DAYLIGHT.
C. THE LOCATIONS OF CALIBRATION ADJUSTMENT EQUIPMENT ARE READILY ACCESSIBLE ONLY TO
AUTHORIZED PESONNEL.
DOCUMENTATION REQUIREMENTS
THE CONSTRUCTION DOCUEMENTS SHALL SPECIFY THAT DOCUMENTS CERTIFYING THAT
THE INSTALLED LIGHTING CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF
IECC SECTION C405 ARE TO BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS FROM
THE DATE OF RECEIPT OF CERTIFICATE OF OCCUPANCY.
MANUALS:AN OPERATING AND MAINTENANCE MANUAL SHALL BE PROVIDED AND INCLUDE ALL OF
THE FOLLOWING:
A. SUBMITTAL DATA INDICATED ALL SELECTED OPTIONS FOR EACH PIECE OF LIGHTING EQUIPMENT
AND LIGHTING CONTROLS.
B. OPERATIONS AND MAINTENANCE MANUALS FOR EACH PIECE OF LIGHTING EQUIPMENT.
REQUIRED ROUTINE MAINTENANCE ACTIONS, CLEANING AND RECOMMENDED RELAMPING SHALL
BE CLEARLY IDENTIFIED.
C. A SCHEDULE FOR INSPECTING AND RECALIBRATING ALL LIGHTING CONTROLS.
D. A NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE, INCLUDING RECOMMENDED
SET POINTS.
DWELLING UNIT SPECIFIC
1. PROVIDE SEPARATE LINE ITEM PRICING FOR ALL DWELLING UNIT LOW VOLTAGE SYSTEMS (TELEPHONE,
DATA, CATV, ETC.) AS REQUESTED BY OWNERS AUTHORIZED REPRESENTATIVE. PRE-WIRE DWELLING UNITS
WITH CABLING AND DEVICES AND MAIN TELE/DATA DISTRIBUTION BOX PER SERVING UTILITY REQUIREMENTS.
COORDINATE WITH CENTURY LINK AND COMCAST AND PROVIDE ALL EQUIPMENT AS REQUIRED FOR A
COMPLETE AND OPERABLE INSTALLATION. PROVIDE SEPARATE LINE ITEM PRICING FOR TURN-KEY
SYSTEM(S) INSTALLATION AS DIRECTED. COORDINATE ALL SCOPE PRIOR TO BID AND INCLUDE ALL PRICING
AS DIRECTED.
2. ALL RECEPTACLES INSTALLED WITHIN DWELLING UNITS SHALL COMPLY WITH NEC 210.52 AND 406.12(1)
REQUIREMENTS. PROVIDE ALL REQUIRED GROUND-FAULT CIRCUIT INTERRUPTER (NEC 210.8) AND ARC-
FAULT CIRCUIT INTERRUPTER (NEC 210.12) PROTECTION PER APPLICABLE CODE REQUIREMENTS. LOCATE
ALL DEVICES IN TYPE A UNITS PER CHAPTER 10 OF ICC A117.1 AND IBC CHAPTER 11 AS AMENDED LOCAL
AUTHORITY. ALL DEVICES INSTALLED IN KITCHENS AND OTHER AREAS SHALL BE INSTALLED PER NEC AND
LOCAL AMENDMENTS.
3. COORDINATE ALL DEVICE INSTALLATION IN ALL KITCHENS AND BATHROOMS WITH SPECIFIC UNIT INTERIOR
ELEVATIONS AND ARCHITECTURAL DETAILS. COORDINATE WITH MILLWORK VENDOR FOR ALL DEVICES TO
BE INSTALLED ON OR WITHIN CABINETRY OR MILLWORK PRIOR TO ANY INSTALLATION. COORDINATE
BACKSPLASH LOCATION AND INSTALLATION REQUIREMENTS WITH ARCHITECTURAL DRAWINGS PRIOR TO
ANY INSTALLATION.
4. COORDINATE ELECTRICAL CONNECTION (POWER & CONTROL) REQUIREMENTS FOR ALL MECHANICAL
EQUIPMENT WITH MECHANICAL CONTRACTOR SHOP DRAWINGS. PROVIDE ALL EQUIPMENT FOR A
COMPLETE AND OPERABLE INSTALLATION. VERIFY EXACT LOCATION OF EQUIPMENT WITH MECHANICAL
CONTRACTOR PRIOR TO ANY INSTALLATION AND LOCATE SERVICE AND DISCONNECT SWITCH AS REQUIRED.
PROVIDE CONNECTION TO ROOFTOP AC CONDENSER FROM RESPECTIVE UNIT PANEL, TYPICAL ALL
DWELLING UNITS. RE: PANEL SCHEDULE FOR ADDITIONAL INFORMATION.
5. CONTRACTOR SHALL PROVIDE AND INSTALL ALL RECEPTACLES WITHIN DWELLING UNITS PER NEC 210.52
AND ALL BRANCH CIRCUITS SHALL COMPLY WITH 210.12(A) REQUIREMENTS.
6. ALL SMALL BRANCH CIRCUIT WIRING SHALL BE PROTECTED IN ACCORDANCE WITH NEC 240.4(D)
REQUIREMENTS.
7. ALL BRANCH CIRCUITING AND WIRING WITHIN DWELLING UNITS SHALL BE PER NEC 210.52 REQUIREMENTS.
PROVIDE ALL EXTERIOR OUTLETS PER NEC 210.52(E) REQUIREMENTS. REFER TO TYPICAL DWELLING UNIT
PANEL SCHEDULE FOR ADDITIONAL INFORMATION AND REQUIREMENTS. PROVIDE AFCI/GFCI PROTECTION
PER APPLICABLE REQUIREMENTS TO THE SATISFACTION OF THE INSPECTING AUTHORITY HAVING
JURISDICTION. PROVIDE FLOOR OUTLETS WHERE REQUIRED PER NEC 210.52(A)(2). NOT ALL CONVENIENCE
OUTLETS MAY BE INDICATED ON PLANS AND CONTRACTOR SHALL PROVIDE WHERE REQUIRED PER THE NEC
AND TO THE SATISFACTION OF THE AUTHORITY HAVING JURISDICTION.
8. PROVIDE LIGHTING OUTLETS AND CONTROL PER NEC 210.70(A) REQUREMENTS TO THE SATISFACTION OF
THE INSPECTING AUTHORITY HAVING JURISDICTION.
9. BRANCH CIRCUITING AND WIRING WITHIN DWELLING UNITS SHALL BE PER NEC 210.52 REQUIREMENTS.
REFER TO TYPICAL DWELLING UNIT PANEL SCHEDULE FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
10. PROVIDE ALL RECEPTACLES IN DWELLING UNITS PER NEC 210.52 REQUIREMENTS AS AMENDED BY LOCAL
JURISDICTION. SEE UNITS PLAN NOTES FOR ADDITIONAL REQUIREMENTS.
11. PROVIDE VISIBLE NOTIFICATION ADAPTABLE APPLIANCES IN GROUP R-2 OCCUPANCIES IN DWELLING UNITS
PER IFC 907.5.2.3.4. ALL ACCESSIBLE UNITS REQUIRED SHALL BE PROVIDED WITH VISIBLE NOTIFICATION
APPLIANCES AS PART OF THIS REQUIREMENT AS REQUIRED BY THE IAHJ.
12. ALL DWELLING UNITS SHALL HAVE APPROVED CARBON MONOXIDE ALARMS INSTALLED PER LOCAL
JURISDICTION PURSUANT TO SECTION 310 OF THE INTERNATIONAL PROPERTY MAINTENANCE CODE AND
INTERNATION BUILDING CODE REQUIREMENTS.
13. ALL DWELLING UNITS SHALL HAVE APPROVED CARBON MONOXIDE ALARMS INSTALLED PER LOCAL
JURISDICTION PURSUANT TO SECTION 310 OF THE INTERNATIONAL PROPERTY MAINTENANCE CODE AND
INTERNATION BUILDING CODE REQUIREMENTS.
14. PROVIDE SINGLE AND MULTIPLE-STATION SMOKE ALARMS IN R-2 DWELLING UNITS PER IFC 907.2.11 TO THE
SATISFACTION OF THE INSPECTING AUTHORITY HAVING JURISDICTION.
15. PROVIDE VISIBLE NOTIFICATION APPLIANCES IN GROUP R-2 OCCUPANCIES IN DWELLING UNITS PER IFC
907.6.2.3.4. ALL ACCESSIBLE UNITS REQUIRED SHALL BE PROVIDED WITH VISIBLE NOTIFICATION APPLIANCES
AS PART OF THIS REQUIREMENT. SINGLE AND MULTIPLE-STATION SMOKE ALARMS (120VAC) SHALL BE
INTEGRATED WITH VISIBLE NOTIFICATION APPLIANCES FOR OCCUPANT NOTIFICATION WITHIN EACH
DWELLING UNIT OR SLEEPING UNIT. VISIBLE NOTIFICATION APPLIANCES ACTIVATED BY THE BUILDING FIRE
ALARM SYSTEM SHALL BE PROVIDED IN DWELLING UNITS AND SLEEPING UNITS. THESE VISIBLE
NOTIFICATION APPLIANCES SHALL BE LOCATED IN THE LIVING ROOMS, SLEEPING ROOMS, KITCHENS AND
TOILET ROOMS.
LOW-VOLTAGE SYSTEM
1. TELECOMMUNICATION, CABLE TELEVISION, SECURITY, A/V, ACCESS CONTROL, INTERCOM, AND OTHER LOW
VOLTAGES SYSTEMS SHALL BE DESIGNED BY OTHERS. ALTHOUGH DRAWINGS MAY INDICATE KEY DEVICES
AND PIECES OF EQUIPMENT FOR THESE SYSTEMS, THEY ARE NOT INTENDED TO BE COMPREHENSIVE.
CONTRACTOR SHALL PROVIDE ELECTRICAL CONNECTIONS TO ALL LINE VOLTAGE EQUIPMENT SERVING
THESE SYSTEMS TO INCLUDE CONDUIT, CONDUCTORS, AND TERMINATIONS AS NECESSARY. CONTRACTOR
SHALL COORDINATE WITH APPROPRIATE LOW VOLTAGE SYSTEM CONSULTANT TO PROVIDE A COMPLETE
AND FUNCTIONAL SYSTEM. PROVIDE SEPARATE LINE ITEM PRICING FOR EACH SYSTEM TO OWNERS
AUTHORIZED REPRESENTATIVE FOR CONSIDERATION. PROVIDE COMPLETE TURN-KEY SYSTEM INCLUDING
ALL DESIGN AND INSTALLATION FOR ALL LOW VOLTAGE SYSTEMS AS DIRECTED BY OWNERS AUTHORIZED
REPRESENTATIVE.
2. PROVIDE 4" SQUARE (DOUBLE GANG) JUNCTION BOX WITH SINGLE GANG PLASTER RING FOR ALL NEW
COMBINATION TELEPHONE/DATA OUTLETS. STUB 3/4" EMPTY CONDUIT UP TO 6" ABOVE ACCESSIBLE CEILING
WITH PULL WIRE IN CONDUIT AND PLASTIC BUSHINGS ON CONDUIT ENDS. ALL COMMUNICATION DEVICES
AND WIRING FOR THE TENANT'S COMMUNICATION SYSTEM SHALL BE INSTALLED BY THE TENANT'S VENDOR
UNDER SEPARATE CONTRACT. COORDINATE EXACT REQUIREMENTS AND OUTLET LOCATIONS WITH
ARCHITECTURAL PLANS PRIOR TO ROUGH IN,TYPICAL.
FIRE ALARM SYSTEM
1. OCCUPANCY TYPES ARE INDICATED ON ARCHITECTURAL CODE SUMMARY SHEETS. ALTHOUGH DRAWINGS
MAY INDICATE KEY DEVICES AND PIECES OF EQUIPMENT FOR THE FIRE ALARM SYSTEM, THEY ARE NOT
INTENDED TO BE COMPREHENSIVE. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS AND
SYSTEM APPROVAL BY LOCAL FIRE PREVENTION AUTHORITIES. REFER TO PROJECT SPECIFICATIONS FOR
ADDITIONAL INFORMATION AND REQUIREMENTS.
2. FIRE ALARM SYSTEM SHALL BE DESIGN-BUILD IN COMPLIANCE WITH APPLICABLE INTERNATIONAL BUILDING
CODE, NFPA 72, AND ALL LOCAL FIRE CODES AND SUBMITTED AS A DELEGATED DESIGN BY OTHERS.
ALTHOUGH DRAWINGS MAY INDICATE KEY DEVICES AND PIECES OF EQUIPMENT FOR THE FIRE ALARM
SYSTEM, THEY ARE NOT INTENDED TO BE COMPREHENSIVE. DELEGATED DESIGN SUBMITTAL DOCUMENTS
SHALL ALSO INCLUDE DESIGN AND SPECIFICATIONS FOR A 2-WAY COMMUNICATION SYSTEM AT ACCESSIBLE
ELEVATOR LANDINGS PER IBC 1007.8.1 AS APPROVED BY LOCAL FIRE DEPARTMENT. FIRE ALARM
CONTRACTOR SHALL PROVIDE COMPLETE ENGINEERED SHOP DRAWINGS SUBMITTAL FOR OWNER AND
ENGINEER'S REVIEW INCLUDING ALL PLANS AND SYSTEM INFORMATION REQUIRED FOR REVIEW AND
APPROVAL BY LOCAL FIRE PREVENTION AGENCY AS A DELEGATED DESIGN SUBMITTAL. THE CONTRACTOR
IS RESPONSIBLE FOR OBTAINING ALL PERMITS AND SYSTEM APPROVAL BY LOCAL FIRE PREVENTION
AUTHORITIES. COORDINATE ALL REQUIREMENT FOR ELEVATOR EMERGENCY OPERATION AND CONTROL
PER INSPECTING AUTHORITY HAVING JURISDICTION.
3. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FULLY ENGINEERED FIRE ALARM SHOP DRAWINGS FOR
REVIEW BY THE LOCAL BUILDING AND FIRE DEPARTMENT. THE FIRE ALARM SHOP DRAWINGS SHALL BE
SIGNED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER IN THE PROJECT'S STATE.
GENERAL REQUIREMENTS
1. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST EDITIONS OF THE NATIONAL ELECTRICAL CODE
(NEC), INTERNATIONAL BUILDING CODE (IBC), AND ALL LOCAL BUILDING AND FIRE CODES. IN THE EVENT OF A
CONFLICT BETWEEN THE CONSTRUCTION DOCUMENTS AND THE DOCUMENTS LISTED ABOVE, THE
CONTRACTOR SHALL CONSULT THE ENGINEER OF RECORD PRIOR TO PROCEEDING WITH THE INSTALLATION
IN QUESTION.
2. ALL WORK SHALL BE COORDINATED WITH THE OTHER TRADES BEFORE INSTALLATION. MATERIALS
INSTALLED IN AN ARBITRARY MANNER OR CREATES AN UNFAIR CONDITION OR HARDSHIP FOR ANOTHER
TRADE WILL NOT BE ACCEPTED.
3. ALL ELECTRICAL WORK PERFORMED SHALL BE BY A DULY LICENSED COLORADO ELECTRICAL CONTRACTOR
AND DULY LICENSED ELECTRICIANS.
4. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT AND TESTING FOR THE ELECTRICAL
DISTRIBUTION SYSTEM DEPICTED ON THESE DRAWINGS.
5. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE GENERAL ARRANGEMENT OF
ELECTRICAL WORK. DO NOT SCALE DRAWINGS. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE
EXACT FITTING OF ALL MATERIALS, EQUIPMENT, ETC. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS
AND IN FIELD PRIOR TO COMMENCEMENT OF WORK.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD-COORDINATING ALL CIRCUIT REQUIREMENTS AND
SHALL PROVIDE ALL INFRASTRUCTURE REQUIRED FOR A COMPLETE AND FUNCTIONAL SYSTEM.
7. "PROVIDE" SHALL BE UNDERSTOOD TO MEAN "FURNISH" AND "INSTALL".
8. ALL DEVICES AND EQUIPMENT SHALL BE NEW AND UL LISTED.
9. ALL SMALL BRANCH CIRCUIT WIRING SHALL BE PROTECTED IN ACCORDANCE WITH NEC 240.4(D)
REQUIREMENTS.
10. FIELD VERIFY EXISTING EQUIPMENT OR CIRCUITS THAT ARE REMAINING TO BE RECONNECTED TO NEW OR
EXISTING SWITCHBOARDS/PANELBOARDS. PROVIDE SWITCHES, RECEPTACLES, CONDUIT, WIRE, ETC. AS
REQUIRED TO RESTORE CONTINUITY OF CIRCUIT(S).
11. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR
LOCATION AND EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO
DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS AS REQUIRED TO MAINTAIN
AND/OR RESTORE CONTINUITY OF SERVICE TO EXISTING CIRCUITS.
12. PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED CONDUIT, WIRE, CABLE, J-BOXES,
RECEPTACLES, SWITCHES, LIGHTS, FIRE ALARM DEVICES, ETC. COMPLETE WITH ASSOCIATED CIRCUITING
TO SOURCE. WHERE IT IS NOT FEASIBLE TO REMOVE THE ABOVE OUTLET SHALL BE ABANDONED, WIRE
REMOVED AND BLANK COVER PLATES PROVIDED.
13. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL PROVIDE ACCURATE DIRECTORIES FOR
ALL PANELBOARDS PER NEC 408.4 REQUIREMENTS. DIRECTORIES SHALL BE COMPUTER GENERATED. EACH
CIRCUIT SHALL BE IDENTIFIED AS TO ITS SPECIFIC PURPOSE OR USE. THE IDENTIFICATION SHALL BE
SUFFICIENTLY DETAILED TO DISTINGUISH EACH CIRCUIT FROM ALL OTHERS.
14. ALL NEW DEVICES INSTALLED IN UNFINISHED SPACES SHALL BE SURFACE MOUNTED WITH A STEEL COVER
PLATE. ALL NEW DEVICES INSTALLED IN FINISHED SPACES SHALL BE FLUSH MOUNTED IN WALL WITH A
WHITE NYLON COVER PLATE. ALL NEW DEVICES SHALL BE WHITE BODIED. PROVIDE TYPEWRITTEN LABELS
ON ALL COMMON SPACE DEVICE COVER PLATES IDENTIFYING THE BRANCH CIRCUIT(S) CONTAINED WITHIN,
INCLUDING THE SOURCE PANELBOARD NAME.
15. ALL ELECTRICAL BOXES FOR LIGHTING, SWITCHING, AND POWER SHALL BE REVIEWED AND APPROVED BY
OWNER PRIOR TO PULLING WIRE. COORDINATE BOX WALK WITH GENERAL CONTRACTOR PRIOR TO
INSTALLING ANY WIRING. COORDINATE DEVICES ABOVE/BELOW/WITHIN MILLWORK WITH MILLWORK AND
APPLIANCE PACKAGE SHOP DRAWINGS AND LOCATE ALL DEVICES/ELECTRICAL SERVICE AS REQUIRED FOR
SPECIFIC LOCATION/APPLIANCE, TYPICAL.
16. COORDINATE MOUNTING HEIGHTS AND LOCATIONS OF ALL ELECTRICAL DEVICES LOCATED WITHIN, ABOVE,
OR NEAR MILLWORK WITH ARCHITECTURAL DRAWINGS, APPROVED "SHOP DRAWINGS", AND MILLWORK
CONTRACTOR. MAINTAIN CONSISTENT MOUNTING PRACTICES FOR A UNIFORM APPEARANCE. VERIFY ALL
OUTLET REQUIREMENTS PRIOR TO ROUGH IN.
17. CONTRACTOR WILL BE RESPONSIBLE TO COORDINATE NEW SERVICES FOR BUILDING WITH THE
NECESSARY UTILITY CONTACTS. PROVIDE APPROPRIATE SERVICE APPLICATIONS FOR ALL SERVICES AS
REQUIRED. COORDINATE EXACT REQUIREMENTS WITH OWNERS AUTHORIZED REPRESENTATIVE PRIOR TO
BID AND INCLUDE ALL COSTS FOR ALL SYSTEMS AS DIRECTED FOR A COMPLETE AND OPERABLE
INSTALLATION. COORDINATE ALL NEW SERVICES TO BUILDING WITH AUTHORIZED UTILITY COMPANY SERVICE
REPRESENTATIVE PRIOR TO ANY INSTALLATION. PROVIDE ALL EQUIPMENT AND RACEWAYS AS DIRECTED
FOR A COMPLETE AND OPERABLE INSTALLATION.
18. ELECTRICAL CONTRACTOR SHALL KEEP AND MAINTAIN AN ACCURATE AND UP-TO-DATE (INCLUDING ALL
OFFICIAL ADDENDUMS, ASI's. AND RFI CHANGES ISSUED) AS-BUILT SET OF CONSTRUCTION DOCUMENTS
DETAILING ALL AS-BUILT CONDITIONS. SUBMIT TO ARCHITECT OR OWNER'S AUTHORIZED REPRESENTATIVE
AT PROJECT COMPLETION.
19. ELECTRICAL SYSTEMS AND COMPONENTS INSTALLED WITHIN OR PENETETRATING RATED ASSEMBLIES
SHALL COMPLY WITH ALL APPLICABLE CODES INCLUDING:
A. ALL ELECTRICAL BOXES INSTALLED IN FIREWALLS SHALL BE LISTED FOR THE INSTALLATION IN RATED
FIREWALLS. PROVIDE SUITABLE OUTLET BOXES TO MEET THE SPACING REQUIREMENTS SET BY THE UL
CERTIFICATIONS DIRECTORY FOR OUTLET BOXES AND FITTINGS CERTIFIED FOR FIRE RESISTANCE. RATED
ASSEMBLY LOCATIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS PRIOR TO ANY
INSTALLATION.
B. THE CONTRACTOR SHALL PROVIDE APPROPRIATE FIRESTOPPING FOR ALL FIRE RATED ASSEMBLY
PENETRATIONS. FIRESTOPPING SYSTEM SHALL BE UL LISTED AND TESTED IN ACCORDANCE WITH ASTM
E814 OR ASTM E119 WITH AN F RATING EQUAL TO THE FIRE RATING OF PENETRATED ASSEMBLY.
21. MECHANICAL EQUIPMENT ELECTRICAL REQUIREMENTS SHALL BE COORDINATED WITH GENERAL
CONTRACTOR & MECHANICAL CONTRACTOR AS REQUIRED PRIOR TO BID:
A. COORDINATE ELECTRICAL CONNECTION & CONTROL REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT
WITH MECHANICAL CONTRACTOR'S SHOP DRAWINGS. PROVIDE ALL EQUIPMENT FOR A COMPLETE AND
OPERABLE INSTALLATION. VERIFY EXACT LOCATION OF EQUIPMENT WITH MECHANICAL CONTRACTOR
PRIOR TO ANY INSTALLATION AND LOCATE SERVICE AND DISCONNECT SWITCH AS REQUIRED. PROVIDE
120V CONNECTION TO ALL MOTORIZED DAMPERS PER EQUIPMENT VENDOR SPECIFICATIONS WHERE
REQUIRED. COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO ANY INSTALLATION AND PROVIDE ALL
CONNECTIONS AS REQUIRED.
B. PROVIDE FUSIBLE DISCONNECT SWITCH WITH FUSES FOR ALL MECHANICAL EQUIPMENT PER EQUIPMENT
MANUFACTURER SPECIFICATIONS IF NOT PROVIDED WITH EQUIPMENT. COORDINATE WITH MECHANICAL
CONTRACTOR AND INCLUDE ALL COSTS IN BASE BID PROPOSAL FOR A COMPLETE AND OPERABLE
INSTALLATION.
C. REFER TO MECHANICAL DRAWINGS FOR LOCATION OF LINE VOLTAGE EQUIPMENT (THERMOSTATS AND
DAMPERS) THAT REQUIRE ELECTRICAL CONNECTIONS. FURNISH CONDUIT, CONDUCTORS, DISCONNECT
SWITCHES AND TERMINATIONS AS NECESSARY.
1. COORDINATE ALL FLOOR PENETRATIONS THROUGH PODIUM STRUCTURE FOR ALL POWER,
COMMUNICATIONS, LOW VOLTAGE CONDUIT WITH STRUCTURAL AND G.C. PRIOR TO DRILLING TO AVOID
DAMAGE TO SLAB TENDONS. COORDINATE SLEEVE LOCATIONS PRIOR TO CONCRETE POUR WHERE EVER
POSSIBLE TO AVOID CORE DRILLING.
2. PRIOR TO SUBMITTING BIDS, THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING
ELECTRICAL EQUIPMENT CONDITIONS AND DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE WORK.
NOTIFY THE ARCHITECT AND ENGINEER OF ANY EXISTING CONDITIONS, WHICH MODIFY THE SCOPE OF WORK
AS SHOWN ON THE CONSTRUCTION DOCUMENTS. SUBMISSION OF A BID PROPOSAL WILL BE CONSTRUED AS
EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR MOBILIZATION, LABOR,
EQUIPMENT, AND/OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE
RECOGNIZED.
3. REFER TO ARCHITECTURAL AND MECHANICAL EQUIPMENT DRAWINGS FOR EXACT LOCATIONS OF
ELECTRICAL DEVICES AND LIGHT FIXTURES. DO NOT SCALE FROM THE ELECTRICAL PLANS. ADDITIONAL
ELECTRICAL REQUIREMENTS ON ARCHITECTURAL PLANS, KITCHEN EQUIPMENT PLANS, AND MECHANICAL
PLANS SHALL BE INCLUDED IN THE ELECTRICAL CONTRACTOR'S BID.
EQUIPMENT REQUIREMENTS
1. ALL NEW PANELBOARDS ARE BASED ON SQUARE D NQOD, NF, OR I-LINE SERIES. LOAD CENTERS SHALL
NOT BE USED IN LIEU OF PANELBOARDS WITH THE EXCEPTION OF DWELLING UNIT PANELS. BUS BARS SHALL
BE ALUMINUM AND LUGS SHALL BE ALUMINUM SUITABLE FOR LANDING COPPER OR ALUMINUM
CONDUCTORS. OTHER ACCEPTABLE MANUFACTURERS INCLUDE SIEMENS, CUTLER-HAMMER, EATON, AND
GE. ALL NEW PANELBOARDS SHALL BE BY THE SAME MANUFACTURER.
2. CIRCUIT BREAKERS IN OTHER THAN DWELLING UNIT PANELS SHALL BE BOLT-ON TYPE UON.
3. CONTRACTOR SHALL PROVIDE A TYPEWRITTEN PANELBOARD CIRCUIT DIRECTORY PER NEC 408.4 TO
INDICATE ALL LOADS SERVED BY THE PANELBOARD. DIRECTORY SHALL SPECIFICALLY LIST THE NATURE OF
THE LOAD (LIGHTING, RECEPTACLES, AHU-1, ETC.) AS WELL AS THE LOCATION (EX. ROOM #, NORTH
CORRIDOR, EXTERIOR, SOUTH STAIRWELL, ETC.). HANDWRITTEN DIRECTORIES ARE NOT ACCEPTABLE.
4. FILLER PLATES SHALL BE PROVIDED FOR ALL UNUSED SPACES IN PANELBOARDS AND SWITCHBOARDS.
CONTRACTOR SHALL MINIMIZE ANY UNUSED SPACES.
5. WIRING IN PANELBOARD GUTTERS SHALL BE NEATLY ARRANGED, GROUPED AND BUNDLED WITH WIRE TIES.
6. PERFORM LOAD-BALANCING CIRCUIT CHANGES AS REQUIRED. DIFFERENCE EXCEEDING 20 PERCENT
BETWEEN PHASE LOADS, WITHIN A PANELBOARD, IS NOT ACCEPTABLE. REBALANCE AND RECHECK AS
NECESSARY TO MEET MINIMUM REQUIREMENTS. RECORD ALL LOAD READINGS BEFORE AND AFTER
CHANGES AND SUBMIT TEST RECORDS.
7. MINIMUM WORKING CLEARANCES PER THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE SHALL BE
PROVIDED AROUND AND IN FRONT OF ALL ELECTRICAL EQUIPMENT.
8. ALL CIRCUIT BREAKER LUGS SHALL BE RATED FOR A MINIMUM OF 75 DEGREE CELSIUS.
9. ALL NEW AND MODIFIED ELECTRICAL EQUIPMENT, SUCH AS SWITCHBOARDS, PANELBOARDS, INDUSTRIAL
CONTROL PANELS, METER SOCKET ENCLOSURES, AND MOTOR CONTROL CENTERS, THAT ARE IN OTHER
THAN DWELLING OCCUPANCIES, AND ARE LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR
MAINTENANCE WHILE ENERGIZED SHALL BE FIELD MARKED TO WARNQUALIFIED PERSONS OF POTENTIAL
ELECTRIC ARC FLASH HAZARDS. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO
QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE
EQUIPMENT PER NEC 2011, ARTICLE 110.16.
POWER REQUIREMENTS
1. UNLESS NOTED OTHERWISE, ALL NEW BRANCH CIRCUIT AND FEEDER CONDUCTORS 8AWG AND LARGER
SHALL BE STRANDED COPPER WITH THHN/THWN INSULATION, SIZED PER NEC 220 REQUIREMENTS. EACH
NEW CIRCUIT SHALL BE PROVIDED WITH EQUIPMENT GROUND CONDUCTORS SIZED PER NEC 250.122
REQUIREMENTS.
2. FOR 120/208V, THREE PHASE SYSTEMS, PHASE CONDUCTORS SHALL BE RED, BLACK, AND BLUE JACKETED.
THE NEUTRAL CONDUCTOR SHALL BE WHITE JACKETED AND GROUND CONDUCTOR SHALL BE GREEN
JACKETED. COLOR CODING SHALL BE CONSISTENT THROUGHOUT THE ENTIRE PROJECT.
3. UNLESS NOTED OTHERWISE, ALL NEW CONDUIT SHALL BE ELECTRICAL METALLIC TUBING (EMT), SIZED PER
NEC REQUIREMENTS. LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC) SHALL BE USED FOR NO MORE THAN
THE LAST SIX FEET OF ALL MOTOR CONNECTIONS. MINIMUM CONDUIT SIZE SHALL BE 3/4". WIRING METHODS
MAY BE AS ALLOWED BY LEGALLY ADOPTED AND ENFORCED CODES AND THE INSPECTING AUTHORITY
HAVING JURISDICTION.
4. WHERE STRANDED WIRE IS USED, WIRING DEVICES SHALL HAVE TERMINALS DESIGNED AND LISTED FOR
TERMINATING STRANDED WIRE OR BY THE USE OF A LISTED CONNECTOR.
5. RECEPTACLES SHALL BE STRAIGHT BLADE, DUPLEX, NEMA 5-20R, COMMERCIAL GRADE AND SHALL COMPLY
WITH NEMA WD 1, NEMA WD 6, DSCC W-C-596G, AND UL 498. COLOR AS DIRECTED BY ARCHITECT TO BE
COMPATIBLE WITH INTERIOR COLOR SCHEME. ALL DEVICES INSTALLED IN DWELLING UNITS SHALL BE
TAMPER RESISTANT PER NEC 406.12 REQUIREMENTS.
6. GFI RECEPTACLES SHALL BE STRAIGHT BLADE, HEAVY DUTY GRADE, NEMA 5-20R, AND SHALL COMPLY WITH
UL943. COLOR AS DIRECTED BY ARCHITECT TO BE COMPATIBLE WITH INTERIOR COLOR SCHEME. ALL
DEVICES IN DWELLING UNITS SHALL BE TAMPER RESISTANT PER NEC 210.52 AND 406.12(1) REQUIREMENTS.
7. TOGGLE SWITCHES SHALL BE HEAVY DUTY GRADE, QUIET TYPE, AND SHALL COMPLY WITH DSCC W-C-896F
AND UL 20. COLOR AS DIRECTED BY ARCHITECT TO BE COMPATIBLE WITH INTERIOR COLOR SCHEME.
8. DIMMER SWITCHES SHALL BE SLIDE TYPE AND SHALL BE FULLY RATED FOR THE WATTAGE OF THE LIGHTING
CIRCUIT TO BE CONTROLLED. DIMMER SWITCHES SHALL BE COMPATIBLE WITH THE DIMMING BALLAST OR
DRIVER PROVIDED. COLOR AS DIRECTED BY ARCHITECT TO BE COMPATIBLE WITH INTERIOR COLOR
SCHEME.
9. WALL PLATES IN FINISHED SPACES SHALL BE STAINLESS STEEL TYPE WITH BRUSHED FINISH UON.
10. WALL PLATES IN UNFINISHED SPACES SHALL BE GALVANIZED STEEL TYPE.
11. ALL 15 AMPERE AND 20 AMPERE, 125 VOLT AND 250 VOLT NON-LOCKING RECEPTACLES INSTALLED IN DAMP
OR WET LOCATIONS SHALL BE LISTED AS WEATHER-RESISTANT PER 2011 NEC, ARTICLE 406.9 (A) AND (B).
ALL RECEPTACLES MOUNTED IN WET LOCATIONS AS REFERENCED ABOVE SHALL HAVE AN "IN-USE"
WEATHERPROOF COVER.
12. ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN OTHER THAN DWELLING
UNITS SHALL HAVE GFCI PROTECTION FOR PERSONNEL IN THE FOLLOWING AREAS: BATHROOMS, KITCHENS
(AREAS WITH A SINK AND PERMANENT FACILITIES FOR FOOD PREPARATION AND COOKING), ROOFTOPS,
OUTDOORS AND WITHIN 6 FEET FROM THE OUTSIDE EDGE OF SINKS, PER 2011 NEC 210.8 (B).
13. IN ALL DWELLING UNIT AREAS SPECIFIED IN 2011 NEC 210.52, ALL 125 VOLT, 15 AND 20-AMPERE
RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES PER 2011 NEC 406.12.
14. ALL BRANCH CIRCUITING SUPPLYING OUTLETS IN AREAS SPECIFIED IN 2011 NEC 210.12 (A) SHALL BE ARC-
FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF A BRANCH
CIRCUIT.
15. VERIFY ALL SPECIFIC KITCHEN EQUIPMENT REQUIREMENTS WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH
IN. COORDINATION SHALL INCLUDE MOUNTING HEIGHTS, CONNECTION TYPE AND POWER REQUIREMENTS.
ALL CONNECTIONS FOR KITCHEN EQUIPMENT SHALL BE IN ACCORDANCE WITH EQUIPMENT
MANUFACTURER'S AND SUPPLIER'S RECOMMENDATIONS.
16. VERIFY ALL SPECIFIC COMPUTER AND COMMUNICATIONS EQUIPMENT REQUIREMENTS WITH EQUIPMENT
SUPPLIER PRIOR TO ROUGH IN. COORDINATION SHALL INCLUDE MOUNTING HEIGHTS, CONNECTION TYPE
AND POWER REQUIREMENTS. ALL CONNECTIONS FOR COMPUTER AND COMMUNICATIONS EQUIPMENT
SHALL BE IN ACCORDANCE WITH EQUIPMENT MANUFACTURER'S AND SUPPLIER'S RECOMMENDATIONS.
LIGHTING REQUIREMENTS
1. PROVIDE LIGHT FIXTURE TYPES AND QUANTITIES AS INDICATED ON THE DRAWINGS.
2. LIGHT FIXTURES: PER UL1598 (LUMINAIRES), NEMA ANSLG 078.81, LED LAMPS: ANSI C78.377, UL 8750.
3. FIXTURES RECESSED IN CEILING SHALL NOT DEPEND ON CEILING GRID, TILE OR PLASTER FOR SUPPORT.
PROVIDE TIE WIRES ATTACHED WITHIN 6 INCHES OF EACH CORNER TO SUPPORT WEIGHT OF EACH FIXTURE
FROM THE STRUCTURE.
4. ALL NEW EMERGENCY LUMINAIRES SHALL MEET UL924, AS WELL AS ALL APPLICABLE NFPA 101, NEC, AND
OSHA ILLUMINATION STANDARDS.
5. ALL LIGHT FIXTURES SHALL BE SUPPORTED INDEPENDENTLY FROM STRUCTURE. REFER TO
ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF LIGHT FIXTURES AND ELECTRICAL DEVICES.
6. ALL LUMINAIRE INSTALLATIONS SHALL COMPLY WITH APPLICABLE CODES; SEE LUMINAIRE SCHEDULES,
DETAILS, AND PLANS FOR ADDITIONAL REQUIREMENTS:
A. COORDINATE ALL DECORATIVE LIGHTING FIXTURE LOCATIONS AND MOUNTING HEIGHTS WITH
ARCHITECTURAL DRAWINGS AND DETAILS PRIOR TO ANY INSTALLATION. DO NOT LOCATE ANY
DECORATIVE SURFACE MOUNTED LIGHTS PER THESE DRAWINGS. CONFIRM WITH ARCHITECT ALL
REQUIREMENTS PRIOR TO ROUGH-IN.
B. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN (RCP) FOR ADDITIONAL INFORMATION AND
REQUIREMENTS. COORDINATE INSTALLATION OF ALL LIGHTING WITH RCP AND OTHER TRADES TO ENSURE
MINIMAL CONFLICTS DURING INSTALLATION.
C. RECESSED LIGHTING INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR
LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. ALL RECESSED LUMINAIRES SHALL BE
IC-RATED AND LABELED AS MEETING ASTM E 283 IECC REQUIREMENTS OR LOCAL AMENDMENTS.
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E001
ELECTRICAL
SPECIFICATIONS
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
E3/3/2023
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E101
ELECTRICAL SITE
PLAN
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
E3/3/2023
1
2
34
6
7
33 3 3 34
MDP
LCP9
G1 G2 G3 G4 G5 G6
HP-3
LEVEL 2
HP-5
LEVEL 2
HP-1HP-1 HP-1 HP-1 HP-1
HP-7HP-5
HP-5
HP-5
HP-5
X2
G1-1 G2-1 G3-1 G4-1 G5-1 G6-1
G1-5 G2-5 G3-5 G4-5 G5-5 G6-5
G1-3 G2-3 G3-3
G4-3 G5-3 G6-3
H1 H1
H1
H1H1
H1
H1
H5 H5 H5 H5 H5 H5
HP-7
HP-7
HP-7
HP-7
5 TYP.
5 TYP.
TYP.
HP-13
HP-13
HP-11
HP-21
TYP.
TYP.
TYP.
HP-11
H1
H1
H1
H1 H1
H1 H1
H1
H7H7HP-12 HP-12
HP-14,16
HP-21
10
GARAGE
2
GARAGE
3
GARAGE
4
GARAGE
5
GARAGE
6
GARAGE
7
EUH-2 EUH-2 EUH-2EUH-2EUH-2EUH-2
EUH-1 EUH-1 EUH-1
G1-6,8 G2-6,8 G3-6,8 G4-6,8 G5-6,8 G6-6,8
DBP-1
HP-11
HP-8,10
HP-2,4,6
EM
HP-1
H1
HP-13
H1
HP-3
HP-3
EUH-1
HP-30,32
OC
EM
HP-3
EM
HP-3
HP-18,20
HP-21
GFI
WP
G1-2,4 G2-2,4 G3-2,4 G4-2,4 G5-2,4 G6-2,4
MECHANICAL
ROOM
94
SOLAR INVERTER
95
STORAGE
96
STORAGE
97
STORAGE
98
STORAGE
99
STORAGE
100
STORAGE
101
'HP'
WP
WP
FACP
X1
HP-3
EM
HP-7
OC
GFI
OC OC
EUH-3
HP-26,28
HP-15
11
HP-1 H1
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E201
ELECTRICAL
LEVEL 1 FLOOR
PLAN
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 ELECTRICAL LEVEL 1 FLOOR PLAN
PROPOSED LOCATION OF BUILDING MAIN DISTRIBUTION BOARD.
PROPOSED LOCATION OF HOUSE EQUIPMENT PANEL
PROPOSED LOCATON OF GARAGE PANEL
LEVEL 1 EV CHARGER READY LOCATION TO BE FIELD COORDINATED WITH
ARCHITECT AND OWNER. PROVIDE 1/2"C (2) #12 + #12GND TO PANEL G*.
CONNECT EXIT SIGNS AND EMERGENCY LIGHTING UNITS TO DESIGNATED
CIRCUIT, AHEAD OF ALL CONTROLS.
PROVIDE LIGHT FIXTURE, TYPE AS INDICATED. SEE HOUSE LIGHT FIXTURE
SCHEDULE.
PROVIDE RECEPTACLE FOR POWERED GARAGE DOOR OPENER
PROVIDE CONNECTION TO PUMP ASSEMBLY, HEAVY DUTY NEMA 3R
DISCONNECT FUSED TO MANUFACTURERS REQUIREMENTS PER LABEL, TYPICAL
PROVIDE LIGHTING CONTROL PANEL OR LIGHTING RELAY PANEL AND 7-DAY
PROGRAMMABLE ASTRONOMICAL TIMECLOCK FOR THE CONTROL OF THE
HOUSE LIGHTING FIXTURES
STUB 1/2"C ABOVE CEILING FROM ENTRY DOOR/FRAME ASSEMBLY FOR ACCESS
CONTROL/DOOR STRIKE (BY OTHERS).
ROUTE 1-1/4" SPARE CONDUIT FROM EACH OF (11) UNIT PANELS TO INVERTER
ROOM AND ROUTE (11) 1-1/4" CONDUITS FROM INVERTER ROOM VERTICALLY TO
ROOF FOR FUTURE TIE IN TO PV SYSTEM. PROVIDE PULL STRINGS AND CAP
OPEN ENDS OF CONDUIT. REFER TO ONE-LINE AND PANEL SCHEDULES FOR
ADDITIONAL INFORMATION.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
KEYED NOTES:X
2 VE CHANGES 03/03/2023
2
2 2
E3/3/2023
HP-1
HP-1 HP-1
HP-1
HP-1
EM
HP-1
X2 EM
H1
H1 H1
H1
H1
HP-3
HP-1
PROVIDE LIGHT FIXTURE, TYPE AS INDICATED. SEE HOUSE LIGHT FIXTURE
SCHEDULE.
CONNECT EXIT SIGNS AND EMERGENCY LIGHTING UNITS TO DESIGNATED
CIRCUIT, AHEAD OF ALL CONTROLS.
CONTINUE TO ALL OTHER DEVICES ON SAME CIRCUIT
1.
2.
3.
KEYED NOTES:X
1 TYP.
2 TYP.
HP-17
HP-17
LEVEL 1
LEVEL 3
LEVEL 1
LEVEL 3
EUH-3
HP-22,24
EM
HP-3
EM
HP-3
HP-3
H7
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E202
ELECTRICAL
LEVEL 2 FLOOR
PLAN
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 ELECTRICAL LEVEL 2 FLOOR PLAN
2 VE CHANGES 03/03/2023
2
E3/3/2023
HP-1
HP-1
HP-1 HP-1
HP-1
HP-1
HP-1
H1
H1
H1 H1
H1
EM
HP-1
EM X21
TYP.
2 TYP.
PROVIDE LIGHT FIXTURE, TYPE AS INDICATED. SEE HOUSE LIGHT FIXTURE
SCHEDULE.
CONNECT EXIT SIGNS AND EMERGENCY LIGHTING UNITS TO DESIGNATED
CIRCUIT, AHEAD OF ALL CONTROLS.
CONTINUE TO ALL OTHER DEVICES ON SAME CIRCUIT
1.
2.
3.
KEYED NOTES:X
HP-17
HP-17
H1
H1
HP-3
HP-3
LEVEL 2
EM
HP-3
EM
HP-3
H7
HP-3
3
LEVEL 2
3
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E203
ELECTRICAL
LEVEL 3 FLOOR
PLAN
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 ELECTRICAL LEVEL 3 FLOOR PLAN
2 VE CHANGES 03/03/2023
2
E3/3/2023
1
3
5
6
7
9 8
2
2
10
10
11TYP.12
14
EF-1
15
EF-1
15
S
16
S
S
4TYP.TVTVTV
13 TYP.
A
A
A
A
A A
A
A
A
AA
E
C
G
B
B
B
GFI
GFI
GFI17
18
GFI
GFI
3
3
AC
GFI
21
21
A
GFI
D
D
EWH-1
20TYP.
12
VTAC-1
19
F
F
3
1
5
6
7
8
9
10
10
13
4 TYP.
11 TYP.
12
14
EF-1
15
EF-1
15
S
16
S
S
TVTV
TVTYP.
A A
A A
A
A
A
A
A
A
C
G
E
A
2
2
AC
GFI
AC
GFI
17
GFI
GFI
B
B
B
18GFI
GFI 3
3
AC
GFI
21
21
A
D
D
20 TYP.
VTAC-1
19
F
F
A A
AA
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E401
ELECTRICAL UNIT
PLANS
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
1/4" = 1'-0"1 2 BR - TYPE 2 UNIT ELECTRICAL PLAN
1/4" = 1'-0"2 2 BR - TYPE 3 UNIT ELECTRICAL PLAN
ELECTRICAL CONTRACTOR (EC) SHALL BE COMPLETELY RESPONSIBLE TO PROVIDE AND PROPERLY LOCATE ALL REQUIRED RECEPTACLES IN
DWELLING UNITS AS REQUIRED TO COMPLY WITH NEC 210.52 REQUIREMENTS WITHOUT EXCEPTION. PROVIDE AFCI PROTECTION PER NEC
210.12(A). RECEPTACLES SHALL BE TAMPER-RESISTANT PER NEC 406.12(A)(1) REQUIREMENTS. GFCI PROTECTION SHALL BE PROVIDED FOR ALL
DEVICES AND/OR CIRCUITS PER NEC 210.8. GFCI PROTECTION SHALL BE PROVIDED FOR OUTLETS THAT SUPPLY DISHWASHERS PER 2017 NEC
210.8(D) REQUIREMENTS. CONTRACTOR SHALL PROVIDE ALL GENERAL-USE CONVENIENCE RECEPTACLES AS REQUIRED IN ALL DWELLING UNITS
PER NEC 210.52 REQUIREMENTS WHETHER INDICATED ON THE DRAWINGS OR NOT. NOT EVERY REQUIRED OUTLET MAY BE SHOWN CORRECTLY
LOCATED ON THE DWELLING UNIT LAYOUTS PROVIDED. CONTRACTOR SHALL INCLUDE ALL FLOOR OUTLETS AS MAY BE REQUIRED PER NEC
210.52(A)(2) WHETHER INDICATED ON THE DRAWINGS OR NOT IF REQUIRED TO MEET MINIMUM CODE REQUIREMENTS BY THE IAHJ. PROVIDE WP
GFCI RECEPTACLE AT ALL DWELLING UNIT BALCONIES PER NEC 210.52(E)(3) REQUIREMENTS. DWELLING UNIT LAYOUTS ARE PROVIDED FOR
GENERAL REQUIREMENTS AND INFORMATION ONLY AND ARE NOT SPECIFIC INSTALLATION DRAWINGS INDICATING EXACT LOCATION OF ALL
DEVICES OR EQUIPMENT OR DETAILING EVERY INSTALLATION REQUIREMENT TO MEET ALL APPLICABLE CODES AND ADOPTED AMENDMENTS TO
THE SATISFACTION OF THE IAHJ. IT SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO INCLUDE ALL LABOR AND
MATERIALS IN BASE BID PROPOSAL FOR ALL ITEMS REQUIRED FOR A COMPLETE AND OPERABLE INSTALLATION TO THE SATISFACTION OF THE
IAHJ. NO RFI'S OR CHANGE ORDERS WILL EVEN BE CONSIDERED, REVIEWED OR APPROVED FOR ANY REQUIRED ADDITIONAL ITEMS AS NOTED
ABOVE AS MAY BE REQUIRED BY THE IAHJ DURING ROUGH AND/OR FINAL INSPECTION. IT IS EXPECTED THAT THE ELECTRICAL CONTRACTOR
HAS PROVIDED THE REQUIRED FUNCTION AS A LICENSED ELECTRICAL CONTRACTOR WHILE PREPARING A CONSTRUCTION ESTIMATE AND BID
PROPOSAL THAT ACCOUNTS FOR AND INCLUDES ALL SCOPE OF WORK REQUIRED FOR A COMPLETE AND OPERABLE INSTALLATION ACCEPTABLE
TO THE IAHJ IN ACCORDANCE WITH NEC 210.52 REQUIREMENTS.
PROVIDE AND INSTALL WP GFCI MAINTENANCE RECEPTACLES PER NEC 210.63 AT ALL GROUND MOUNTED AND/OR ROOF MOUNTED HACR
EQUIPMENT WHETHER INDICATED ON THE DRAWINGS OR NOT. PROVIDE DEDICATED 20A 120V BRANCH CIRCUIT FROM NEAREST AVAILABLE
HOUSE PANEL IF NO BRANCH CIRCUIT IS INDICATED ON THE DRAWINGS. PROVIDE 10AWG THWN CU CONDUCTORS FOR CIRCUITS IN EXCESS OF
75' IN LENGTH AND 8AWG THHN CU CONDUCTORS FOR CIRCUITS IN EXCESS OF 125' IN LENGTH, TYPICAL FOR ALL BUILDINGS.
COORDINATE ALL INTERIOR AND EXTERIOR RECEPTACLE/LUMINAIRE INSTALLATIONS IN/ON EXTERIOR LOAD-BEARING PARTITIONS WITH GENERAL
CONTRACTOR TO ENSURE THERE ARE NO CONFLICTS WITH STUD PACKS OR SHEAR WALL SYSTEMS. DO NOT MODIFY ANY STRUCTURAL
ELEMENT WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. ALL BACKBOXES REQUIRED FOR
DEVICES/LUMINAIRES SHALL BE RECESS MOUNTED. COORDINATE FUR-OUT OF WALL OR PROVIDE FLOOR MOUNTED RECEPTACLE AS
NECESSARY FOR INTERIOR OUTLETS. FINAL INSTALLATION SHALL BE ACCEPTABLE THE IAHJ AND OAR. DO NOT SUBMIT AN RFI FOR THESE
CONDITIONS OR REQUEST SPECIFIC INSTALLATION DETAILS UNLESS DESIGN DIRECTION IS ABSOLUTELY REQUIRED TO RESOLVE THE
CONDITION. CONTRACTORS SHALL BE RESPONSIBLE TO FIELD COORDINATE ALL OCCURENCES AND SHALL BE RESPSONSIBLE FOR ALL
INSTALLATION MEANS AND METHODS FOR A COMPLETE AND OPERABLE INSTALLATION TO SUIT THE APPLICATION.
LOCATE ALL ELECTRICAL EQUIPMENT TO PROVIDE ALL REQUIRED WORKING CLEARANCES PER NEC 110.26 REQUIREMENTS TO THE
SATISFACTION OF THE IAHJ.
COORDINATE WITH MECHANICAL AND PLUMBING DRAWINGS/CONTRACTORS FOR EXACT LOCATIONS OF ALL EQUIPMENT. VERIFY POINT OF
SERVICE AND ROUTE FEEDER/BRANCH CIRCUIT WIRING AS REQUIRED TO SUIT FIELD CONDITIONS. ROUTE ALL WIRING OUT OF PUBLIC VIEW AS
MUCH AS POSSIBLE.
REFER TO ARCHITECTURAL OR INTERIOR DESIGNER REFLECTED CEILING PLANS (RCP) FOR EXACT LOCATION OF ALL LUMINAIRES. IF NO RCP IS
PROVIDED, LOCATE ALL LUMINAIRES TO BEST ILLUMINATE THE SPACE AND CENTERED IN AVAILABLE SPACE COORDINATED WITH ALL OTHER
CEILING ITEMS SUCH AS MECHANICAL EQUIPMENT OR LIFE SAFETY SYSTEM DEVICES. COORDINATE ALL LOCATIONS WITH OAR DURING BOX
WALK PRIOR TO ANY WIRING INSTALLATION TO ENSURE ACCEPTABLE INSTALLATION PRIOR TO INSTALLATION OF ANY WIRING.
ALL EQUIPMENT EXPOSED TO WEATHER SHALL BE NEMA 3R RATED TO SUIT THE APPLICATION.
THE ELECTRICAL CONTRACTOR SHALL BE COMPLETELY RESPONSIBLE FOR DETERMINING AND PROVIDING ALL PROPER WIRING MEANS AND
METHODS FOR ALL BUILDING TYPES, CONDITIONS/APPLICATIONS, COORDINATION OF ROUTING AND INSTALLATION OF ALL FEEDERS AND
INSTALLATION OF ALL EQUPMENT PER ALL APPLICABLE CODES WITH ALL OTHER TRADES PRIOR TO ANY INSTALLATION TO THE SATISFACTION OF
THE IAHJ. WHERE WIRING MEANS OR METHODS ARE INDICATED ON THESE DRAWINGS THEY ARE MINIMUM REQUIREMENTS ONLY AND THE
ELECTRICAL CONTRACTOR SHALL CONFIRM ACCEPTABLE INSTALLATION METHODS AND MATERIALS WITH THE IAHJ PRIOR TO ANY INSTALLATION,
TYPICAL.
VERIFY ALL DEVICE TYPE, COLOR AND MATCHING COVER PLATE COLOR WITH OAR AND/OR ARCHITECT. DEVICE ORIENTATION SHALL BE
VERTICAL UNLESS OTHERWISE INDICATED OR DIRECTED BY OAR/ARCHITECT. VERIFY EXACT REQUIREMENTS PRIOR TO ANY INSTALLATION AND
INSTALL ALL EQUIPMENT AS DIRECTED.
PROVIDE APPROVED CO DETECTOR OR APPROVED COMBINATION SMOKE/CO DETECTOR IN ALL DWELLING UNITS WHERE REQUIRED TO THE
SATISFACTION OF THE IAHJ. ALL EQUIPMENT PROVIDED SHALL HAVE 120V PRIMARY POWER WITH BATTERY BACKUP PER APPLICABLE CODE
REQUIREMENTS.
IT IS FULLY EXPECTED AND REQUIRED THAT THE EC SHALL BE RESPONSIBLE TO THOROUGHLY COORDINATE WITH ARCHITECTURAL PLANS,
INTERIOR ELEVATIONS, ALL APPLIANCE INSTALLATION MANUALS AND FINAL APPROVED MILLWORK VENDOR SHOP DRAWINGS TO VERIFY ALL
REQUIREMENTS FOR ELECTRICAL CONNECTIONS AND EXACT LOCATIONS WITHIN MILLWORK PRIOR TO ANY INSTALLATION. PROVIDE ALL
BACKBOXES, OULETS, SUPPORTS, ETC. AS REQUIRED FOR A COMPLETE AND OPERABLE INSTALLATION. NOTES ON DRAWINGS HAVE BEEN
PROVIDED TO ALERT CONTRACTOR TO VARIOUS ITEMS/ISSUES BUT SHALL NOT BE CONSTRUED AS BEING COMPLETE IN ANY WAY. ENGINEER
ASSUMES NO LIABILITY FOR OUTLET/CONNECTION TYPE/DEVICE LOCATIONS, ETC. FOR ANY DEVICE OR CONNECTION INSTALLED WITHIN
DWELLING UNITS. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED COORDINATION WITH KITCHEN EQUIPMENT/APPLIANCE VENDORS
AND SHOP DRAWINGS, ALL MILLWORK SHOP DRAWINGS/CONTRACTOR AND OAR TO ENSURE ALL EQUIPMENT IS PROPERLY ACCOUNTED FOR
AND CORRECTLY LOCATED PRIOR TO ANY INSTALLATION TO AVOID ANY CONFLICTS DURING ACTUAL INSTALLATION.
EC SHALL SCHEDULE A "BOX WALK" WITH OAR AFTER ALL OUTLET BOXES HAVE BEEN INSTALLED, BUT PRIOR TO INSTALLING ANY WIRING TO
VERIFY EXACT LOCATION OF ALL DEVICES. ONCE OAR CONFIRMS APPROVAL OF ALL LOCATIONS, ROUGH WIRING MAY OCCUR. ANY ROUGH
WIRING INSTALLED PRIOR TO BOX WALK AND OAR APPROVAL SHALL BE AT CONTRACTORS SOLE RISK AND SHALL BE RELOCATED OR
RECONFIGURED AT CONTRACTORS SOLE EXPENSE IF INSTALLED WIRING DOES NOT MEET PROJECT REQUIREMENTS AS DETERMINED BY OAR.
IT IS FULLY EXPECTED AND REQUIRED THAT THE EC SELECTED AND AWARDED THE CONTRACT FOR THIS PROJECT WILL HAVE PREVIOUSLY
PERFORMED MANY PROJECTS SIMILAR TO THIS PROJECT'S SIZE AND SCOPE AND THEREFORE IS FULLY PREPARED AND ABLE TO UNDERSTAND
THE REQUIRED SCOPE OF WORK AND IN FACT HAS INCLUDED ALL THE NECESSARY COORDINATION, PRE-PLANNING AND ADDITIONAL SCOPE OF
WORK THAT IS REQUIRED TO SUCCESSFULLY COMPLETE A PROJECT OF THIS SIZE AND SCOPE WITHOUT UNNECESSARY RFI'S, QUESTIONS OR
NEED FOR SPECIFIC ADDITIONAL DIRECTION FROM THE DESIGN TEAM ON COMPLETING THE PROJECT. PROJECT EXECUTION BY THE ELECTRICAL
CONTRACTOR SHALL INCLUDE THE PROPER LAYOUT AND INSTALLATION OF ALL REQUIRED BRANCH CIRCUITING PER 2017 NEC ARTICLE 210 AS
AMENDED BY THE CITY OF LONE TREE PER SEC. 18-7-40. THE OWNER EXPECTS THIS LEVEL OF EXPERIENCE AND COMPETENCE SHALL RESULT IN
A PROJECT WITHOUT UNDUE RFI'S AND CHANGE ORDERS FOR "MISSING ITEMS" THAT MAY NOT BE EXPLICITLY INDICATED ON THE DRAWINGS,
BUT ARE NECESSARY FOR A COMPLETE AND OPERABLE INSTALLATION. REFER TO GENERAL NOTES ABOVE FOR ADDITIONAL EXPECTATIONS
AND REQUIREMENTS TO BE INCLUDED IN THE CONTRACTORS BASE SCOPE OF WORK AND SPECIFIC CONTRACT REQUIREMENTS.
PER 2018 IECC R404.1; NOT LESS THAN 90% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH-EFFICACY LAMPS.
CONTRACTOR SHALL PROVIDE ALL DOCUMENTATION TO IAHJ AS MAY BE REQUIRED FOR CERTIFICATION AND APPROVAL FOR OCCUPANCY.
ELECTRICAL CONTRACTOR (EC) SHALL FULLY COORDINATE WITH OWNERS LOW VOLTAGE DESIGN CONSULTANT (LVDC) TO INCLUDE ALL SCOPE
ELEMENTS FOR ALL LOW VOLTAGE SYSTEMS TO AND WITHIN ALL DWELLING UNITS. EC SHALL OBTAIN FINAL APPROVED LVDC DELEGATED
DESIGN DRAWINGS AND SHALL INCLUDE ALL SCOPE ITEMS AS REQUIRED FOR A COMPLETE AND OPERABLE INSTALLATION. VERIFY EXACT
LOCATION AND DEVICE TYPES WITH LVDC DRAWINGS AND OAR PRIOR TO ANY INSTALLATION. LV DEVICE LOCATIONS INDICATED HEREON ARE
FOR REFERENCE USE ONLY AND ARE NOT TO BE USED FOR DETERMINING INSTALLATION REQUIREMENTS OR REQUIRED SCOPE OF WORK. EC
SHALL PROVIDE SEPARATE LINE ITEM PRICING AS DIRECTED BY OAR FOR ALL LOW VOLTAGE SCOPE AS PART OF BASE BID PROPOSAL FOR A
COMPLETE AND OPERABLE INSTALLATION.
REFER TO EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION FOR EQUIPMENT INSTALLATION AND CONNECTION REQUIREMENTS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
GENERAL NOTES:
PROVIDE DEDICATED 15A 120V BRANCH CIRCUIT AND OUTLET FOR
REFRIGERATOR. REFER TO DWELLING UNIT PANEL SCHEDULE FOR ADDITIONAL
INFORMATION AND REQUIREMENTS. LOCATE PER EQUIPMENT MFR
SPECIFICATIONS.
PROVIDE ABOVE-COUNTER DUPLEX GFCI RECEPTACLES FOR SMALL
APPLIANCES PER NEC 210.52(B)(3) AND 210.52(C) REQUIREMENTS. INSTALLATION
SHALL COMPLY WITH NEC 210.8(A) AND 210.12(A) TO THE SATISFACTION OF THE
INSPECTING AUTHORITY HAVING JURISDICTION.
PROVIDE 50A 250V 4-WIRE NEMA 14-50R RECEPTACLE FOR RANGE/OVEN OR PER
EQUIPMENT MFR SPECIFICATIONS AS DIRECTED BY OWNERS AUTHORIZED
REPRESENTATIVE. VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO
ANY INSTALLATION.
REFER TO ARCHITECTURAL DRAWINGS AND DETAILS AND COORDINATE
WITH GENERAL CONTRACTOR FOR ALL LUMINAIRES. PROVIDE ALL
EQUIPMENT AS DIRECTED FOR A COMPLETE AND OPERABLE INSTALLATION.
PROVIDE 30A 250V 4-WIRE NEMA 14-30R RECEPTACLE FOR DRYER UNIT OR PER
EQUIPMENT MFR SPECIFICATIONS. COORDINATE WITH OWNERS EQUIPMENT
VENDOR TO PROVIDE CONNECTION TO 65VA REMOTE IN-LINE FAN AND
CONNECT TO DRYER AS REQUIRED. RE: MECHANICAL DRAWINGS FOR
ADDITIONAL INFORMATION AND REQUIREMENTS.
PROVIDE EXTERIOR OUTLETS PER NEC 210.52(E)(2) & (3) REQUIREMENTS TO
THE SATISFACTION OF THE INSPECTING AUTHORITY HAVING JURISDICTION.
PROVIDE BELOW-COUNTER SWITCHED RECEPTACLE FOR GARBAGE DISPOSAL.
PROVIDE DEDICATED BRANCH CIRCUIT AND SPST AIR SWITCH CONTROLLER,
FLUSH IN COUNTER. COORDINATE INSTALLATION AND LOCATION OF ALL
DEVICES IN MILLWORK WITH GENERAL CONTRACTOR AND MILLWORK VENDOR
PRIOR TO ANY INSTALLATION. PROVIDE CORD AND PLUG IF NOT PROVIDED BY
PLUMBING CONTRACTOR.
PROVIDE RECEPTACLE LISTED FOR USE IN COUNTERTOPS AS REQUIRED PER
NEC 210.52(C)(5) ADJACENT TO SINK. PROVIDE GFCI PROTECTION AS REQUIRED.
COORDINATE INSTALLATION WITH MILLWORK VENDOR AND GENERAL
CONTRACTOR PRIOR TO ANY INSTALLATION.
PROVIDE DEDICATED 20A GFCI BRANCH CIRCUIT FOR DISHWASHER. LOCATE
OUTLET UNDER SINK AND LABEL AS DISHWASHER. COORDINATE INSTALLATION
WITH PLUMBING CONTRACTOR AND LOCATION OF ALL DEVICES IN MILLWORK
PRIOR TO ANY INSTALLATION. PROVIDE GFCI PROTECTION PER NEC 210.8(D).
PROVIDE DEDICATED 20A GFCI BRANCH CIRCUIT TO SERVE DWELLING UNIT
BATHROOMS PER NEC 210.11(C)(3), 210.8(A)(1) AND 210.52(D) REQUIREMENTS.
LOCATE AT SIDEWALL ADJACENT TO MIRROR TO SUIT EACH CONDITION. DO NOT
LOCATE IN MIRROR. VERIFY EXACT LOCATION WITH ARCHITECT PRIOR TO
ROUGH IN AND LOCATE AS DIRECTED.
PROVIDE GENERAL PURPOSE CONVENIENCE OUTLETS THROUGHOUT DWELLING
UNITS PER NEC 210.52 REQUIREMENTS, TYPICAL. VERIFY EXACT LOCATION OF
ALL DEVICES FOR SPECIAL EQUIPMENT SUCH AS TV'S, ETC. PRIOR TO ROUGH IN
AND LOCATE AS DIRECTED.
PROVIDE "MEDIA BOX" FOR LOW VOLTAGE SYSTEMS DISTRIBUTION WITHIN
DWELLING UNIT. PROVIDE ADDITIONAL 120V RECEPTACLE IF REQUIRED.
PROVIDE TELE/DATA CABLING THROUGHOUT DWELLING TO DEVICES AS
REQUIRED.
PROVIDE FAN-RATED CEILING BOX PER NEC 314.27(C). LOCATED AS
DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. PROVIDE 3-WIRE
CONNECTION FOR POSSIBLE FAN/CONTROL AS DIRECTED.
PROPOSED LOCATION OF DWELLING UNIT PANEL. COORDINATE EXACT
LOCATION WITH ARCHITECT AND GENERAL/MECHANICAL CONTRACTORS
PRIOR TO ANY INSTALLATION TO AVOID CONFLICTS WITH OTHER SYSTEMS.
FINAL LOCATION AND INSTALLATION SHALL PROVIDE ALL WORKING
CLEARANCES REQUIRED PER NEC 110.26 REQUIREMENTS. DO NOT LOCATE
PANEL IN CLOTHES CLOSET OR RESTROOMS.
PROVIDE 120V CONNECTION TO EXHAUST FAN. COORDINATE EXACT
REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ANY
INSTALLATION. PROVIDE ALL EQUIPMENT FOR A COMPLETE AND OPERABLE
INSTALLATION. PROVIDE SEPARATE CONTROL SWITCH AS DIRECTED BY
OWNERS AUTHORIZED REPRESENTATIVE.
PROVIDE 120V CONNECTION AND INSTALL UL 217 SMOKE DETECTOR(S) PER
IBC 907.2.11.2 REQUIREMENTS. INTERCONNECT MULTIPLE ALARMS AS
REQUIRED PER IBC 907.2.11.5. INSTALLATION TO BE TO THE SATISFACTION
OF THE INSPECTING AUTHORITY HAVING JURISDICTION (IAHJ). PROVIDE
COMBINATION SMOKE/CO DETECTOR IF ACCEPTABLE TO IAHJ.
PROVIDE DEDICATED 20A 120V BRANCH CIRCUIT TO COMBO MICROWAVE/
RECIRC VENT. COORDINATE EXACT LOCATION AND ALL EQUIPMENT
REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ANY INSTALLATION.
PROVIDE ALL EQUIPMENT FOR A COMPLETE AND OPERABLE INSTALLATION.
PROVIDE DEDICATED 20A 120V BRANCH CIRCUIT FOR LAUNDRY EQUIPMENT PER
NEC 210.11(C)(2) AND 210.52(F) REQUIREMENTS. VERIFY EXACT LOCATION PRIOR
TO ROUGH IN AND LOCATE AS DIRECTED.
VERIFY EXACT LOCATION AND REQUIREMENTS WITH MECHANICAL CONTRACTOR
PRIOR TO ANY INSTALLATION. REFER TO GENERAL NOTES ABOVE FOR
ADDITIONAL REQUIREMENTS. REFER TO EQUIPMENT SCHEDULE FOR
ADDITIONAL INFORMATION AND REQUIREMENTS.
VERIFY TELE/DATA (CATV) DEVICE LOCATIONS WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO ROUGH IN. LOCATE AND PROVIDE ALL EQUIPMENT
AS DIRECTED FOR A COMPLETE AND OPERATION INSTALLATION. PROVIDE
DUPLEX RECEPTACLE ADJACENT TO ALL TELE/DATA AND CATV DEVICES,
TYPICAL. DO NOT INSTALL ANY LOW VOLTAGE SYSTEMS BASED ON THIS UNIT
PLAN.
UNDERCOUNTER LED LIGHTS, TYPE F. PROVIDE STEP DOWN TRANSFORMER AS
REQUIRED. REFER TO LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION
AND REQUIREMENTS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
KEYED NOTES:X
1
1
1 ABCO Comments 01/05/2023
2 VE CHANGES 03/03/2023
2
2
E3/3/2023
1
3
2
2
17
21
21
7
9
F
EF-1
VTAC-2
A AA
TYP.
TYP.
A A
A A
TYP.
E
A
A
EWH-1
A
A
B
B
B
F
F
EF-1
19
A A
A
A
A
A
A
A
A
AA
A
C
E
1223
5
72
10
11 TYP.
13 TYP.
S 16
S
17
18
20
21 21
EWH-1
15
TYP.
VTAC-1
EF-1
23
30 F
F
21
F F
F
19
1
3
5
6
7
9 2
2
8
10
1213
14
EF-1
15
S
16
S
4TYP.
11TYP.
TV
TVTYP.
F
F
A A
A
A
A
A A
A
A
A
A A
A A
B
B
B
C
E
17
18
GFI
GFI
GFI
GFI
3
3
3
3
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E402
ELECTRICAL UNIT
PLANS
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
2 VE CHANGES 03/03/2023
REFER TO GENERAL NOTES ON SHEET E401.1.
GENERAL NOTES:
PROVIDE DEDICATED 15A 120V BRANCH CIRCUIT AND OUTLET FOR
REFRIGERATOR. REFER TO DWELLING UNIT PANEL SCHEDULE FOR ADDITIONAL
INFORMATION AND REQUIREMENTS. LOCATE PER EQUIPMENT MFR
SPECIFICATIONS.
PROVIDE ABOVE-COUNTER DUPLEX GFCI RECEPTACLES FOR SMALL
APPLIANCES PER NEC 210.52(B)(3) AND 210.52(C) REQUIREMENTS. INSTALLATION
SHALL COMPLY WITH NEC 210.8(A) AND 210.12(A) TO THE SATISFACTION OF THE
INSPECTING AUTHORITY HAVING JURISDICTION.
PROVIDE 50A 250V 4-WIRE NEMA 14-50R RECEPTACLE FOR RANGE/OVEN OR PER
EQUIPMENT MFR SPECIFICATIONS AS DIRECTED BY OWNERS AUTHORIZED
REPRESENTATIVE. VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO
ANY INSTALLATION.
REFER TO ARCHITECTURAL DRAWINGS AND DETAILS AND COORDINATE
WITH GENERAL CONTRACTOR FOR ALL LUMINAIRES. PROVIDE ALL
EQUIPMENT AS DIRECTED FOR A COMPLETE AND OPERABLE INSTALLATION.
PROVIDE 30A 250V 4-WIRE NEMA 14-30R RECEPTACLE FOR DRYER UNIT OR PER
EQUIPMENT MFR SPECIFICATIONS. COORDINATE WITH OWNERS EQUIPMENT
VENDOR TO PROVIDE CONNECTION TO 65VA REMOTE IN-LINE FAN AND
CONNECT TO DRYER AS REQUIRED. RE: MECHANICAL DRAWINGS FOR
ADDITIONAL INFORMATION AND REQUIREMENTS.
PROVIDE EXTERIOR OUTLETS PER NEC 210.52(E)(2) & (3) REQUIREMENTS TO
THE SATISFACTION OF THE INSPECTING AUTHORITY HAVING JURISDICTION.
PROVIDE BELOW-COUNTER SWITCHED RECEPTACLE FOR GARBAGE DISPOSAL.
PROVIDE DEDICATED BRANCH CIRCUIT AND SPST AIR SWITCH CONTROLLER,
FLUSH IN COUNTER. COORDINATE INSTALLATION AND LOCATION OF ALL
DEVICES IN MILLWORK WITH GENERAL CONTRACTOR AND MILLWORK VENDOR
PRIOR TO ANY INSTALLATION. PROVIDE CORD AND PLUG IF NOT PROVIDED BY
PLUMBING CONTRACTOR.
PROVIDE RECEPTACLE LISTED FOR USE IN COUNTERTOPS AS REQUIRED PER
NEC 210.52(C)(5) ADJACENT TO SINK. PROVIDE GFCI PROTECTION AS REQUIRED.
COORDINATE INSTALLATION WITH MILLWORK VENDOR AND GENERAL
CONTRACTOR PRIOR TO ANY INSTALLATION.
PROVIDE DEDICATED 20A GFCI BRANCH CIRCUIT FOR DISHWASHER. LOCATE
OUTLET UNDER SINK AND LABEL AS DISHWASHER. COORDINATE INSTALLATION
WITH PLUMBING CONTRACTOR AND LOCATION OF ALL DEVICES IN MILLWORK
PRIOR TO ANY INSTALLATION. PROVIDE GFCI PROTECTION PER NEC 210.8(D).
PROVIDE DEDICATED 20A GFCI BRANCH CIRCUIT TO SERVE DWELLING UNIT
BATHROOMS PER NEC 210.11(C)(3), 210.8(A)(1) AND 210.52(D) REQUIREMENTS.
LOCATE AT SIDEWALL ADJACENT TO MIRROR TO SUIT EACH CONDITION. DO NOT
LOCATE IN MIRROR. VERIFY EXACT LOCATION WITH ARCHITECT PRIOR TO
ROUGH IN AND LOCATE AS DIRECTED.
PROVIDE GENERAL PURPOSE CONVENIENCE OUTLETS THROUGHOUT DWELLING
UNITS PER NEC 210.52 REQUIREMENTS, TYPICAL. VERIFY EXACT LOCATION OF
ALL DEVICES FOR SPECIAL EQUIPMENT SUCH AS TV'S, ETC. PRIOR TO ROUGH IN
AND LOCATE AS DIRECTED.
PROVIDE "MEDIA BOX" FOR LOW VOLTAGE SYSTEMS DISTRIBUTION WITHIN
DWELLING UNIT. PROVIDE ADDITIONAL 120V RECEPTACLE IF REQUIRED.
PROVIDE TELE/DATA CABLING THROUGHOUT DWELLING TO DEVICES AS
REQUIRED.
PROVIDE FAN-RATED CEILING BOX PER NEC 314.27(C). LOCATED AS
DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. PROVIDE 3-WIRE
CONNECTION FOR POSSIBLE FAN/CONTROL AS DIRECTED.
PROPOSED LOCATION OF DWELLING UNIT PANEL. COORDINATE EXACT
LOCATION WITH ARCHITECT AND GENERAL/MECHANICAL CONTRACTORS
PRIOR TO ANY INSTALLATION TO AVOID CONFLICTS WITH OTHER SYSTEMS.
FINAL LOCATION AND INSTALLATION SHALL PROVIDE ALL WORKING
CLEARANCES REQUIRED PER NEC 110.26 REQUIREMENTS. DO NOT LOCATE
PANEL IN CLOTHES CLOSET OR RESTROOMS.
PROVIDE 120V CONNECTION TO EXHAUST FAN. COORDINATE EXACT
REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ANY
INSTALLATION. PROVIDE ALL EQUIPMENT FOR A COMPLETE AND OPERABLE
INSTALLATION. PROVIDE SEPARATE CONTROL SWITCH AS DIRECTED BY
OWNERS AUTHORIZED REPRESENTATIVE.
PROVIDE 120V CONNECTION AND INSTALL UL 217 SMOKE DETECTOR(S) PER
IBC 907.2.11.2 REQUIREMENTS. INTERCONNECT MULTIPLE ALARMS AS
REQUIRED PER IBC 907.2.11.5. INSTALLATION TO BE TO THE SATISFACTION
OF THE INSPECTING AUTHORITY HAVING JURISDICTION (IAHJ). PROVIDE
COMBINATION SMOKE/CO DETECTOR IF ACCEPTABLE TO IAHJ.
PROVIDE DEDICATED 20A 120V BRANCH CIRCUIT TO COMBO MICROWAVE/
RECIRC VENT. COORDINATE EXACT LOCATION AND ALL EQUIPMENT
REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ANY INSTALLATION.
PROVIDE ALL EQUIPMENT FOR A COMPLETE AND OPERABLE INSTALLATION.
PROVIDE DEDICATED 20A 120V BRANCH CIRCUIT FOR LAUNDRY EQUIPMENT PER
NEC 210.11(C)(2) AND 210.52(F) REQUIREMENTS. VERIFY EXACT LOCATION PRIOR
TO ROUGH IN AND LOCATE AS DIRECTED.
VERIFY EXACT LOCATION AND REQUIREMENTS WITH MECHANICAL CONTRACTOR
PRIOR TO ANY INSTALLATION. REFER TO GENERAL NOTES ABOVE FOR
ADDITIONAL REQUIREMENTS. REFER TO EQUIPMENT SCHEDULE FOR
ADDITIONAL INFORMATION AND REQUIREMENTS.
VERIFY TELE/DATA (CATV) DEVICE LOCATIONS WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO ROUGH IN. LOCATE AND PROVIDE ALL EQUIPMENT
AS DIRECTED FOR A COMPLETE AND OPERATION INSTALLATION. PROVIDE
DUPLEX RECEPTACLE ADJACENT TO ALL TELE/DATA AND CATV DEVICES,
TYPICAL. DO NOT INSTALL ANY LOW VOLTAGE SYSTEMS BASED ON THIS UNIT
PLAN.
UNDERCOUNTER LED LIGHTS, TYPE F. PROVIDE STEP DOWN TRANSFORMER AS
REQUIRED. REFER TO LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION
AND REQUIREMENTS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
KEYED NOTES:X
1/4" = 1'-0"1 1 BR - TYPE 1 UNIT ELECTRICAL PLAN
1/4" = 1'-0"2 1 BR - TYPE 2 UNIT ELECTRICAL PLAN
1/4" = 1'-0"3 2 BR - TYPE 6 UNIT ELECTRICAL PLAN
2
2
2 E3/3/2023
ONE-LINE DIAGRAM GENERAL NOTES:
1. ALL SERVICE EQUIPMENT SHALL BE INSTALLED PER NEC REQUIREMENTS AND UTILITY PROVIDER'S SERVICE STANDARDS.
2. ALL DISTRIBUTION EQUIPMENT AND OVERCURRENT DEVICES INDICATED SHALL BE NEW AND IDENTIFIED AS A UL LISTED SERIES TESTED
COMBINATION WITH UPSTREAM FUSE PER NEC 240.86(B) WHERE REQUIRED FOR SCCR RATING INDICATED. PROVIDE ALL EQUIPMENT LABELING
PER NEC 110.22(C). PROVIDE SUBMITTAL DATA FOR REVIEW AND APPROVAL BY ARCHITECT/ENGINEER PRIOR TO ORDERING OR PURCHASING
ANY EQUIPMENT.
3. UTILITY SERVICE EQUIPMENT SHALL BE SHALL BE GROUNDED AND BONDED IN ACCORDANCE WITH NEC 250.80 AND 250.84 REQUIREMENTS.
4. ALL SERVICE EQUIPMENT SHALL BE GROUNDED AND BONDED IN ACCORDANCE WITH NEC 250.24 AND 250.92 REQUIREMENTS.
5. CONTRACTOR'S SERVICE EQUIPMENT VENDOR SHALL PROVIDE ALL REQUIRED ARC FLASH SYSTEM ANALYSIS, DOCUMENTATION AND
EQUIPMENT LABELING PER NEC 110.16, 110.21, 110.22 AND 240.87 REQUIREMENTS TO THE SATISFACTION OF THE INSPECTING AUTHORITY HAVING
JURISDICTION.
6. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL NEW ELECTRICAL SERVICE INSTALLATION REQUIREMENTS WITH UTILITY
AUTHORIZED SERVICE REPRESENTATIVE. COORDINATE EXACT LOCATION OF ALL SITE UTILITIES AND EQUIPMENT WITH FINAL APPROVED UTILITY
SERVICE PLAN. PROVIDE INSTALLATION OF ALL RACEWAY SYSTEMS AND EQUIPMENT AS REQUIRED FOR NEW SERVICE TO BUILDING PER
UTILITY SERVICE STANDARDS AND FINAL APPROVED SERVICE PLAN.
7. ALL SITEWORK AND UNDERGROUND CONDUIT SHALL BE PER UTILITY PROVIDER'S GUIDE FOR CUSTOMER INSTALLED UNDERGROUND CONDUITS
AND VAULTS PRIMARY INSTALLATION AND LATEST ELECTRIC SERVICE CONSTRUCTION STANDARDS (ESCS). VERIFY EXACT REQUIREMENTS
PRIOR TO BID.
8. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH SERVING UTILITIES FOR ALL LOW VOLTAGE SYSTEM SERVICES TO THE BUILDING
INCLUDING, BUT NOT LIMITED TO, TELEPHONE, CATV, SECURITY SYSTEMS, ETC. PROVIDE ALL RACEWAYS AND STRUCTURES AS REQUIRED BY
SERVING UTILITY COMPANIES FOR RESPECTIVE SYSTEMS IN BASE BID PROPOSAL.
9. CONTRACTOR SHALL SUBMIT FOR REVIEW AND APPROVAL EQUIPMENT SHOP DRAWINGS FOR ALL SERVICE ENTRANCE EQUIPMENT,
DISTRIBUTION EQUIPMENT, PANELBOARDS, OR OTHER RELATED EQUIPMENT.
10. ALL ELECTRICAL SERVICE AND DISTRIBUTION EQUIPMENT EXPOSED TO WEATHER SHALL BE NEMA 3R RATED WEATHERPROOF.
11. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING APPLICABLE WIRING MEANS AND METHODS TO SUIT SPECIFIC FIELD
CONDITIONS TO SUIT THE INTENDED APPLICATION. PROVIDE ALL RACEWAYS AND EQUIPMENT PER APPLICABLE CODE REQUIREMENTS. WHERE
RACEWAY TYPES ARE INDICATED HEREON, THEY ARE FOR REFERENCE USE ONLY AND DO NOT NECESSARILY INDICATE THE SPECIFIC RACEWAY
TYPE REQUIRED FOR THE SPECIFIC APPLICATION IN ALL AREAS.
12. PROVIDE SUPPORT FOR ALL CONDUCTORS IN VERTICAL RACEWAYS AS REQUIRED PER NEC 300.19 TO THE SATISFACTION OF THE INSPECTING
AUTHORITY HAVING JURISDICTION.
11[(4-500kcmil Cu) 4"C]
6[(4-400kcmil) 3-1/2"C]
(4#4;#8GND) 1-1/4"C
(4-250kcmil;#4GND) 3"C
1
FEEDER SCHEDULE
2
3
4
NOTE: ALL CONDUCTORS SHOWN ARE ALUMINUM UNLESS OTHERWISE NOTED.
DETAIL NOTES:
COORDINATE WITH OWNERS AUTHORIZED REPRESENTATIVE AND OBTAIN SERVING UTILITY COMPANY (HOLY CROSS ELECTRIC) TO PROVIDE
ELECTRONIC SUBMETERING AS PART OF BASE BID PROPOSAL FOR ALL DWELLING UNITS. INCLUDE ALL EQUIPMENT AND INSTALLATION REQUIRED
FOR A COMPLETE AND OPERABLE ELECTRONIC SUBMETERING SOLUTION. SYSTEM TO BE CAPABLE OF METERING AND ASSOCIATING MULTIPLE
FEEDERS AND BRANCH CIRCUITS TO A SINGLE UNIT.
PROVIDE CIRCUIT BREAKER AND BRANCH CIRCUIT SHOWN TO REMOTE ELECTRONIC SUBMETERING EQUIPMENT. COORDINATE WITH OWNERS
ELECTRONIC SUBMETERING VENDOR EXACT EQUIREMENTS AND EQUIPMENT LOCATIONS PRIOR TO ANY INSTALLATION. REFER TO GENERAL NOTE
25 ON E0.00 FOR ADDITIONAL INFORMATION AND REQUIREMENTS, TYPICAL.
PROVIDE 18AWG UL1015, 600V 221F/105C, TWISTED PAIR BLACK AND WHITE CONDUCTORS FOR CT WIRING FROM CT'S AT "MDP" TO REMOTE MMU.
COORDINATE WITH OWNERS ELECTRONIC SUBMETERING VENDOR EXACT REQUIREMENTS AND EQUIPMENT LOCATIONS PRIOR TO ANY
INSTALLATION. PROVIDE RACEWAY SYSTEM(S) AS REQUIRED TO SUIT THE SPECIFIC INSTALLATION REQUIREMENTS PER EQUIPMENT MFR
SPECIFICATIONS AS DIRECTED BY OWNERS ELECTRONIC SUBMETERING VENDOR.
PROVIDE ARC-ENERGY REDUCTION PER NEC 240.87 REQUIREMENTS.
ROUTE SPARE 1-1/4" CONDUIT FROM EACH TENANT PANEL TO INVERTER ROOM ON THE 1ST FLOOR. ROUTE A 1-1/4" CONDUIT FOR EACH UNIT FROM
INVERTER ROOM TO ROOF AND STUB OUT 1' ABOVE ROOF LEVEL. PROVIDE PULL STRINGS AND CAP OFF ENDS FOR EACH CONDUIT. THESE
CONDUITS ARE FOR FUTURE USE WITH ROOF MOUNTED PV SYSTEMS.
(ASSUMED)
300kVA
208/120V/3Φ
TRANSFORMER
BY HOLY CROSS
ELECTRIC
2
LEVEL 1
1600/3
200/3 60/3 225/2
"MDP", 1600A, 208/120V, 3Φ, 4W, NEMA 3R, 65kAIC
4 3 4
HOUSE
PANEL
"HP"
MCB
WATER
PIPE
UFER GROUND
ROD
UTILITY
METER
N
G
LEVEL 2
LEVEL 3
ESM
TENANT
PANEL
(x3)
MLO
X
1.
2.
3.
4.
5.
4
"MMU"1
2
3
60/2
3
GARAGE
PANEL
(x6)
MLO
3
SECONDARY
CONNECTION
CABINET
4000A
1 #6 Cu GEC
#4 Cu GEC#3/0 Cu GEC
225/2
4
TENANT
PANEL
(x4)
MLO
3
X X X - Isc=56,331
Isc=52,137 - X
Isc=24,054 - X
X - Isc=6,214 X - Isc=20,698
(WORST CASE)(WORST CASE)
225/2
4
TENANT
PANEL
(x4)
MLO
3
BUILDING E
TO BLDG C
TO BLDG D
UM1-3
XFMR
VAULT
ROOF
INVERTER
ROOM
5
X - Isc=57,400
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E602
ELECTRICAL
ONE-LINE
DIAGRAM
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
2 VE CHANGES 03/03/2023
1 BUILDING E - ELECTRICAL ONE-LINE DIAGRAM
ALL CALCULATIONS BASED ON BUSSMAN POINT-TO-POINT METHOD FOR 3 PHASE CIRCUITS.
** FOR INFINITE BUS USE 100,000,000
* MULTIPLY THE TOTAL MOTOR LOAD CURRENT BY 4
1. Transformer short circuit rating based on information received from Holy Cross Metering Guidebook, Table II.
Unit Panel (Worst Case) 45 Al 250 kcmil 1 2 208 12862 52137 20698
Garage Panel (Worst Case) 40 Al #4 1 2 208 2350 52137 6214
PANEL 'HP' 50 Al 250 kcmil 1 2 208 18593 52137 24054
SWBD 'MDP' 25 Al 400 kcmil 6 2 208 145776 56331 52137
TERMINATION CABINET 10 Al 1000... 8 2 208 251920 57400 56331
LOCATION FT. Cu SIZE PH. NON=2 L-L " C " Isc Isc
FAULT LEN. Al/ NO./ MAG=1 VOLT. CIRCUIT BEGINNI... FAULT
CKT COND... COND... CKT
FEEDERS
500kVA XFMR secondary 500 12470 208 1.41 1388 100000... 33400 0 57400
LOCATION KVA L-L L-L %Z FLA Isc** Isc CONTRIB. Isc
FAULT TRANS. VOLT. VOLT. XFMR SEC. PRI. SEC. *MOTOR CONTRIB.
PRI. SEC. XFMR. XFMR. TOTAL
TRANSFORMERS
LOCATION:Eagle Vail DATE:3/3/2023
PROJECT:Haymeadow PROJ. NO.:21234
SHORT CIRCUIT CALCULATIONS
2
2
2
E3/3/2023
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E604
ELECTRICAL
CALCULATIONS
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
***Unit Panel Rating 225A at 120/208V, 1Ø, 3W***
Minimum Service Ampacity at 120/208V, 1Ø, 3W:207
*-Table 220.42 (First 3000VA @ 100%, remainder @ 35%)
Net Calculated Load:42958
Sub-Total: 34819
(1) VTAC Unit 13977 13977
25% Largest Motor 174
(1) Domestic Circ. Pump 168 168
(1) Electric Water Heater @ 125% 6000 7500
(1) Clothes Dryer (Table 220.54) 5000 5000
(1) Electric Oven/Cooktop (Table 220.55) 8000 8000
Equipment
Sub-Total: 3498
(1) Refrigerator 950 712.5
(1) Microwave 1650 1237.5
(1) Dishwasher 1200 900
(1) Garbage Disposal 864 648
Fixed Appliances (220.53)
Demand*: 4641
Sub-Total: 7689
(1) Laundry Circuits, 1500W (220.52(B))1500
(2) Small Appliance Circuits, 1500W (220.52(A)) 3000
1063 Sq. Ft. @ 3VA 3189
General Lighting Load @ 3VA/Sq. Ft. 220.14 (J)NEC 220.42
Basic*
New Single Family Dwelling - 2BR-Largest Unit Main Panel
Description of Load
2020 NEC 220
RESIDENTIAL ELECTRICAL LOAD CALCULATION
Haymeadow - 2BR-Type1 Unit (Largest)
***Main Distribution Panel Rating 1600A at 120/208V, 3Ø, 4W***
Minimum Service Ampacity at 120/208V, 3Ø, 4W:1259
* First 3kW @ 100%, remainder up to 120kW @ 35%, above 120kW @ 25% - Table 220.42
Net Calculated Load: 453673
House Loads 36000
Sub-Total: 74460
(6) Misc. Garage Loads 226 1356
(6) Garage Door Openers 864 5184
(6) Electric Unit Heaters 3000 18000
(6) EV Charging Stations @ 125% 8320 49920
Garage Panels
Sub-Total: 274757
(9) VTAC-2 Units 13977 125793
(2) VTAC-1 Units 10046 20092
25% Largest Motor 174
(11) Domestic Circ. Pump 168 1848
(8) Electric Water Heater EWH-2 6000 60000
(3) Electric Water Heater EWH-1 4000 15000
(11) Electric Clothes Dryer (Table 220.54) 5000 25850
(11) Electric Range/Oven (Table 220.55) 8000 26000
Equipment
Sub-Total: 38478
(11) Refrigerator 950 7838
(11) Microwave 1650 13612.5
(11) Dishwasher 1200 9900
(11) Garbage Disposal 864 7128
Fixed Appliances (220.53)
Demand*: 29978
Sub-Total: 80079
(11) Laundry Circuits, 1500W (220.52(B))16500
(22) Small Appliance Circuits, 1500W (220.52(A))33000
10193 Sq. Ft. @ 3VA 30579
General Lighting Load @ 3VA/Sq. Ft. NEC 220.14 (J)NEC 220.42
Basic*
Total Unit SF: 10193
(4) 2BR-Type4 Unit 906 SF 3624
(4) 2BR-Type5 Unit 1063 SF 4252
(1) 2BR-Type6 Unit 1063 SF 1063
(1) 1BR-Type2 Unit 580 SF 580
(1) 1BR-Type1 Unit 674 SF 674
Unit SF Breakdown Area, SF
Building (11 Units)
Description of Load
2020 NEC 220
RESIDENTIAL ELECTRICAL LOAD CALCULATION
Haymeadow - 11 Unit Building
Ampacity at 120/208V, 3Ø, 4W:3582
* First 3kW @ 100%, remainder up to 120kW @ 35%, above 120kW @ 25% - Table 220.42
Net Calculated Load (VA): 1290592
(3) House Panel 36000 108000
House Loads
Sub-Total: 223380
(18) Misc. Garage Loads 226 4068
(18) Electric Unit Heaters 3000 54000
(18) Garage Door Openers 864 15552
(18) EV Charging Stations @ 125% 6656 149760
Garage Panels
Sub-Total: 774535
(28) VTAC-2 Units 13977 391356
(4) VTAC-1 Units 10046 40184
25% Largest Motor 1819
(32) Domestic Circ Pump 168 5376
(32) Electric Water Heater 6000 240000
(32) Electric Clothes Dryer (Table 220.54) 5000 48800
(32) Electric Range/Oven (Table 220.55) 8000 47000
Equipment
Sub-Total: 111936
(32) Refrigerator 950 22800
(32) Microwave 1650 39600
(32) Dishwasher 1200 28800
(32) Garbage Disposal 864 20736
Fixed Appliances (220.53)
Demand*: 72741
Sub-Total: 235164
(32) Laundry Circuits, 1500W (220.52(B))48000
(64) Small Appliance Circuits, 1500W (220.52(A))96000
30388 Sq. Ft. @ 3VA 91164
General Lighting Load @ 3VA/Sq. Ft. NEC 220.14 (J)NEC 220.42
Basic*
Total Unit SF: 30388
(12) 2BR-Type6 Unit 906 SF 10872
(14) 2BR-Type5 Unit 1063... 14882
(2) 2BR-Type6 Unit 1063 SF 2126
(2) 1BR-Type2 Unit 580 SF 1160
(2) 1BR-Type1 Unit 674 SF 1348
Unit SF Breakdown Area,...
Electrical Load for Electrical Service #1 (Bldgs C, D, E)
Description of Load
2020 NEC 220
RESIDENTIAL ELECTRICAL LOAD CALCULATION
Haymeadow - Electrical Service (Bldgs C, D, E)
2 VE CHANGES 03/03/2023
2 E3/3/2023
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E605
ELECTRICAL
SCHEDULES
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
LUMINAIRE SCHEDULE GENERAL NOTES
1 LUMINAIRES INDICATED ABOVE WERE USED AS A BASIS OF DESIGN; ALTERNATE MANUFACTURERS WILL BE CONSIDERED WITH ARCHITECT'S AND OWNER'S APPROVAL.
2 CATALOG NUMBERS INDICATE BASIC LUMINAIRE TYPES REQUIRED FOR THIS PROJECT. CONTRACTOR SHALL BE RESPONSIBLE TO INCLUDE ALL ACCESSORIES AND HARDWARE REQUIRED FOR FINAL INSTALLATION.
3 ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE FOR VERIFYING LUMINAIRE LOCATIONS AND MOUNTING REQUIREMENTS PRIOR TO PURCHASE. INCLUDE ALL MOUNTING HARDWARE AS REQUIRED FOR A COMPLETE INSTALLATION.
4 FINAL FINISH OF ALL FIXTURES SHALL BE APPROVED IN WRITING BY ARCHITECT.
5 MOUNTING HEIGHTS SHALL BE COORDINATED WITH ARCHITECT'S ELEVATIONS.
6 THE FIXTURE SCHEDULE DOES NOT NECESSARILY LIST ALL ACCESSORIES AND HARDWARE NECESSARY FOR THE COMPLETE INSTALLATION, NOR DOES IT DETAIL THE CEILING CONSTRUCTION TO BE ENCOUNTERED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROPERLY
DETERMINE AND PROVIDE CORR
7 FIXTURES AND TRACKS SHALL BE MOUNTED TO / FROM STRUCTURE IN A MANNER RECOMMENDED BY THE MANUFACTURER WITHOUT COMPROMISING THE INTEGRITY OF THE STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS REQUIRED TO INSURE A SAFE
AND PROPER INSTALLATION.
8 REMOTE TRANSFORMERS, POWER SUPPLIES, OR DRIVERS SHALL BE LOCATED IN NEARBY ACCESSIBLE, CONCEALED-FROM-VIEW LOCATION WITH MANUFACTURER'S RECOMMENDED VENTILATION. CONTRACTOR SHALL SUPPLY MANUFACTURER'S TRANSFORMERS, POWER
SUPPLIES, OR DRIVERS OF PROPER CAPACITY FOR A COMPLETE INSTALLATION.
LIGHTING FOR EXTERIOR APPLICATIONS SHALL COMPLY WITH IECC C405.2.5 AND MEET ALL OF THE FOLLOWING REQUIREMENTS:
1. LIGHTING SHALL BE CONTROLLED BY A DEVICE THAT AUTOMATICALLY TURNS OFF THE LIGHTING WHEN SUFFICIENT DAYLIGHT
IS AVAILABLE.
2. ALL BUILDING FACADE AND LANDSCAPE LIGHTING SHALL BE AUTOMATICALLY CONTROLLED AS A FUNCTION OF DUSK/DAWN AND
A SET BUSINESS OPENING AND CLOSING TIME, OR BETWEEN TIMES ESTABLISHED BY THE AUTHORITY HAVING JURISDICTION.
3. LIGHTING NOT SPECIFIED IN 2. SHALL BE CONTROLLED BY A DEVICE THAT AUTOMATICALLY REDUCES THE CONNECTED
LIGHTING POWER BY AT LEAST 30% FOR AT LEAST ONE OF THE FOLLOWING CONDITIONS:
A. FROM 12 MIDNIGHT OR WITHIN ONE (1) HOUR OF THE END OF BUSINESS OPERATIONS, WHICHEVER IS LATER, UNTIL 6A.M. OR
BUSINESS OPENING, WHICHEVER IS EARLIER.
B. DURING ANY PERIOD WHEN NO ACTIVITY HAS BEEN DETECTED FOR A TIME OF NO LONGER THAN 15 MINUTES.
ALL TIME SWITCHES SHALL BE CAPABLE OF RETAINING PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER FOR A
PERIOD OF AT LEAST TEN HOURS.
EXCEPTIONS:
1. LIGHTING FOR COVERED VEHICLE ENTRANCES OR EXITS FROM BUILDINGS OR PARKING STRUCTURES WHERE REQUIRED FOR
SAFETY, SECURITY, OR EYE ADAPTATION
2. LIGHTING THAT IS INTEGRAL TO SIGNAGE AND INSTALLED IN THE SIGNAGE BY THE MANUFACTURER
EXTERIOR LIGHTINGINTERIOR LIGHTING
LIGHTING FOR INTERIOR APPLICATIONS SHALL COMPLY WITH IECC C405.2 AND MEET ALL OF THE FOLLOWING REQUIREMENTS:
1. OFFICES
2. AUTOMATIC CONTROLS IN CORRIDORS SHALL HAVE THE FOLLOWING:
A. CONTROLLED TO AUTOMATICALLY TO TURN THE LIGHT 'ON' TO 50 PERCENT POWER UPON DIGITAL TIMECLOCK SETPOINT,
1-HOUR BEFORE BUSINESS HOURS
a. OCCUPANT TO MANUALLY TURN 'ON' THE REMAINDER OF THE LIGHTING
b. OCCUPANT MANUAL CONTROLS TO BE FULLY CONTINUOUSLY DIMMABLE
B. LIGHT FIXTURES SHALL AUTOMATICALLY TURN 'OFF' 1-HOUR AFTER END OF BUSINESS HOURS
a. OCCUPANT TO MANUALLY TURN 'OFF' LIGHT FIXTURES
3. AUTOMATIC CONTROLS IN JANITOR CLOSETS, BATHROOMS, AND STORAGE ROOMS SHALL HAVE THE FOLLOWING:
A. AUTOMATICALLY TURN 'ON' THE LIGHT FIXTURES WHEN OCCUPANTS ENTER THE SPACE
B. MANUAL 'ON' OVERRIDE AT ENTRANCE DOOR
C. LIGHT FIXTURES SHALL AUTOMATICALLY TURN 'OFF' WITHIN 20-MINUTES OF ALL OCCUPANTS LEAVING THE SPACE
4. AUTOMATIC CONTROLS IN THE OPEN AREA WAREHOUSE SHALL HAVE THE FOLLOWING:
A. AUTOMATICALLY TURN 'ON' TO 50 PERCENT POWER WHEN OCCUPANTS ENTER THE SPACE
B. MANUAL 'ON' CONTROL AT EACH ENTRANCE DOOR
C. LIGHT FIXTURES SHALL AUTOMATICALLY TURN 'OFF' WITHIN 30-MINUTES OF ALL OCCUPANTS LEAVING THE SPACE
5. MECHANICAL, ELECTRICAL, AND WATER ENTRY ROOMS
A. AUTOMATIC CONTROLS NOT REQUIRED FOR OCCUPANT SAFETY. OCCUPANT TO MANUALLY TURN 'ON' AND MANUALLY
TURN 'OFF' THE LIGHT FIXTURES
• LIGHTING CONTROLS SHALL BE PROVIDED BY LUTRON, LEVITON, GREENGATE, WATTSTOPPER, OR EQUIVALENT
MANUFACTURER AS APPROVED BY OWNER AND ENGINEER. PROVIDE MANUFACTURER'S SHOP DRAWINGS TO ARCHITECT FOR
REVIEW PRIOR TO PURCHASING.
• CONTROL SWITCHES, SENSORS, ETC. SHALL BE LOW-VOLTAGE OR WIRELESS WHENEVER PRACTICAL. INCLUDE ALL
ACCESSORIES, RELAY PACKS, CAT-# CABLING, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION.
• MANUAL DIMMING CONTROLS SHALL BE CAPABLE OF DIMMING LIGHTS TO 0% (OFF) SETTING. DIMMING COMPATIBILITIES
BETWEEN THE LUMINAIRES AND CONTROLS TO BE COORDINATED BY THE CONTRACTOR TO ENSURE PROPER OPERATION.
LUMINAIRES MUST BE ABLE TO DIM TO THE LEVEL INDICATED ON THE LUMINAIRE SCHEDULE.
• REMOTE LIGHTING CONTROL DEVICES (TIMECLOCKS, ETC.) SHALL BE CENTRALLY LOCATED IN ELECTRICAL ROOM, UNLESS
INDICATED OTHERWISE ON PLANS. COORDINATE AND CONFIRM WITH OWNER PRIOR TO ROUGH-IN.
• ALL SWITCHES AND SENSORS SHALL BE LABELED TO IDENTIFY THE AREA CONTROLLED.
• ELECTRICAL CONTRACTOR SHALL LOCATE SENSORS AS PROVIDED BY MANUFACTURER PER APPROVED SHOP DRAWINGS.
CONTROL LOCATIONS INDICATED ON THE DRAWINGS ARE FOR REFERENCE PURPOSES ONLY AND WILL BE ALTERED AS
NECESSARY FOR CORRECT OPERATION BY MANUFACTURER.
• PROJECT TO HAVE FUNCTIONAL PERFORMANCE TESTING OF ALL LIGHTING SYSTEMS AND PROVIDE OWNER WITH REPORT OF
DOCUMENTED PERFORMANCE WITHIN 90 DAYS OF RECEIPT OF CERTIFICATE OF OCCUPANCY. TESTING SHALL INCLUDE
SYSTEM COMMISSIONING AS REQUIRED BY IECC C408.
• DAYLIGHT RESPONSIVE CONTROLS SHALL BE PROVIDED WHERE REQUIRED PER IECC C405.2.3 REQUIREMENTS. LIGHTS AND
SENSORS IN THESE AREAS MUST BE INDEPENDENTLY CONTROLLED AND BE CAPABLE OF DIMMING FROM 10%-100%.
• PROGRAMMING, FACTORY START-UP AND TRAINING TO END-USER STAFF SHALL BE BY LIGHTING CONTROLS MANUFACTURER
OR AUTHERIZED REPRESENTATIVE. CONTRACTOR SHALL INCLUDE AT LEAST ONE FOLLOW-UP VISITS WITH LIGHITNG CONTROL
REPRESENTATIVE FOR FOLLOW-UP TRAINING OR ANY ADDITIONAL PROGRAMMING WITH OWNER IN BASE BID PROPOSAL.
• COMPLETE LIGHTING CONTROLS SYSTEM SHALL BE AS SIMPLIFIED AS ALLOWED BY IECC C405.2. STAND-ALONE AND SINGLE
ROOM CONTROLS IS PREFERED OVER CENTRAL CONTROL PANELS. DESIGN ALTERNATES AS ALLOWED BY CODE TO SIMPLIFY
THE DESIGN SHALL BE CONSIDERED AND REVIEWED BY THE ENGINEER WHERE PROPOSED BY CONTROLS MANUFACTURER OR
CONTRACTOR.
GENERAL REQUIREMENTS
LIGHTING CONTROLS REQUIREMENTS
LUMINAIRE SCHEDULE - ALTERNATE LIGHT FIXTURES AND CONTROLS
1 THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ANY INCURRED HOURS REQUIRED TO UPDATE THE PERMIT OR CONSTRUCTION DOCUMENTS DUE TO ALTERNATE FIXTURES OR CONTROLS BY THE ENGINEER OF RECORD.
2 THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ANY INCURRED HOURS REQUIRED FOR THE ENGINEER OF RECORD TO REVIEW ALTERNATE LIGHT FIXTURES OR CONTROLS.
3 UPDATES SHALL BE BILLED AT AN HOURLY RATE OF $150/HR OR AS PREVIOUSLY AGREED TO RATES IN THE CONTRACT DOCUMENTS.
LUMINAIRE SCHEDULE NOTES: ALL LUMINAIRES, LAMPS/DRIVERS, ACCESSORIES SHALL BE PROVIDED BY CONTRACTOR AS PART OF BASE BID SCOPE.
HC620D010-HM60525-830
G 6" LED SHOWER LIGHT HALO RECESSED 120V 21 3000K 80 2228 - WET LISTED
LED-T24P-1-1-WT
F UNDERCOUNTER LED STRIP... WAC LIGHTING SURFACE 120V 3 3000K - - - PROVIDE REQUIRED STEP-DOWN TRANSFORMER\POWER...
HS71003-125EEXTERIOR WALL SCONCE HOMESTYLE LIGHTING WALL 120V 14 3000K - 1440 - WET LISTED, INSTALL 14W A19 LED LAMP
P2708-09
D BATHROOM VANITY LIGHT PROGRESS LIGHTING WALL 120V 42 3000K - 4320 - INSTALL (3) 14W A19 LED LAMPS
P500149-143
C DINING RM LED PENDANT PROGRESS LIGHTING PENDANT 120V 14 3000K - 1440 - INSTALL 14W A19 LED LAMP
PD-26611-SN
B 4" ROUND LED PENDANT WAC LIGHTING PENDANT 120V 15 3000K 90 858 ELV, 10%
HC620D010-HM60525-830
A 6" LED DOWNLIGHT HALO RECESSED 120V 21 3000K 80 2228 -
CATALOG NUMBER
TYPE DESCRIPTION MANUFACTURER & MOUNTING VOLTAGE WATTAGE CCT CRI LUMENS DIMMING REMARKS
UNIT LUMINAIRE SCHEDULE
LUMINAIRE SCHEDULE NOTES: ALL LUMINAIRES, LAMPS/DRIVERS, ACCESSORIES SHALL BE PROVIDED BY CONTRACTOR AS PART OF BASE BID SCOPE.
90-MINUTE BACKUP BATT. SQ-LED-W-SD
EM EMERGENCY LIGHT MULE WALL 120-277V - - - - -
90-MINUTE BACKUP BATT. HCXUGW03L SPECIFIC INSTALLATION REQUIREMENTS, TYPICAL FOR ALL...
X2 EXIT SIGN & EM LIGHT COMBO DUAL LITE UNIVERSAL 120-277V - - - - - PROVIDE ALL MOUNTING HARDWARE/ACCESSORIES AS...
EVE U G W E I SPECIFIC INSTALLATION REQUIREMENTS, TYPICAL FOR ALL...X1 EXIT SIGN DUAL LITE UNIVERSAL 120-277V - - - - - PROVIDE ALL MOUNTING HARDWARE/ACCESSORIES AS...
HS71003-125
H7 WALL SCONCE HOMESTYLE LIGHTING WALL 120V 14 3000K - - - WET LISTED, INSTALL 14W A19 LED LAMP
FVS8 M 4 2 LO OS1
H5 4' LINEAR SURFACE LED FAIL-SAFE WALL 120-277V 45.5 3000K 80+ 5675 -
FVS4W M 2 1 LO 30 P187 WALL
H4 2' LINEAR SURFACE LED FAIL-SAFE SURFACE 120-277V 12.3 3000K 80+ 1230 -
FVS4 M 2 1 LO 30 P187 CEILING
H3 2' LINEAR SURFACE LED FAIL-SAFE SURFACE 120-277V 12.3 3000K 80+ 1230 -
FSV8 M 2 LD4 2 STD 30 P187 CEILING
H2 2' LINEAR SURFACE LED FAIL-SAFE SURFACE 120-277V 33.5 3000K 80+ 3718 -
SLD606 8 30 WH
H1 6" LED DOWNLIGHT HALO RECESSED 120-277V 12.2 3000K 80 760 0-10V, 5%
CATALOG NUMBER
TYPE DESCRIPTION MANUFACTURER & MOUNTING VOLTAGE WATTAGE CCT CRI LUMENS DIMMING REMARKS
HOUSE LUMINAIRE SCHEDULE
E3/3/2023
studio
DRAWN BY:
CHECKED BY:
DATE:
REVISION:
COPYRIGHT 2023
This document is an instrument of service, and as such
remains the property of the Architect. Permission for use
of this document is limited and can be extended only by
written agreement with EVstudio, LLC.
Denver, CO
Evergreen, CO
Meridian, ID
303.670.7242
inspections@evstudio.com
design@evstudio.com
www.evstudio.com
Contact:
E606
ELECTRICAL
SCHEDULES
KH
CT
21234
PERMIT SET
11/16/2022HAYMEADOW CONDOSBUILDING C91 MT. HOPE CIR.EAGLE, COLORADOShane Donalson
shane.donalson@evstudio.com
303.670.7242
REMAINDER IN EXCESS OF 10KVA+ALLOWABLE DEMAND FOR COMMERCIAL COOKING EQUIPMENT (IF APPLICABLE) PER NEC 220.56 REQUIREMENTS.
* - FEEDER DEMAND KVA INDICATED IS THE SUM OF CONN.KVA (CODE 1)X125%+100% OF CONN.KVA (CODE 2)+100% OF FIRST 10KVA OF GENERAL-USE RECEPTACLES PER NEC 220.44 AND 50% OF
PANEL:HP
ISSUE DATE:6.13.22 FEEDER DEMAND AMPS 95.9
BY:CT FEEDER DEMAND KVA*34.5
CONN.KVA (CODE 4)0.0 NEC 220.56
CONN.KVA (CODE 3)2.0 NEC 220.44
CONN.KVA (CODE 2)22.8 100
NOTES:107.5 97.6 52.1 CONN.KVA (CODE 1 )7.8 125
TOTAL 12897 11714 6249 CONNECTED KVA 30.9 DEMAND %/NEC REF.
41 20 1 SPARE ///////// ///////// 0 SPARE 1 20 42
39 20 1 SPARE ///////// 0 ///////// SPARE 1 20 40
37 20 1 SPARE 0 ///////// ///////// SPARE 1 20 38
35 20 1 SPARE ///////// ///////// 0 SPARE 1 20 36
33 20 1 SPARE ///////// 0 ///////// SPARE 1 20 34
31 1 --- --- ---375 1875 ///////// ///////// 1500 --- --- --- 2 32
29 1 20 2 LTG - SITE 375 ///////// ///////// 1875 1500 EUH-1 - LVL 1 STAIRWELL 2 20 2 30
27 1 --- --- ---3328 ///////// 4828 ///////// 1500 --- --- --- 2 28
25 1 40 2 EV Charging Station 3328 4828 ///////// /////////1500 EUH-3 - LVL 1 CORRIDOR 2 20 2 26
23 20 1 SPARE ///////// ///////// 1500 1500 --- --- --- 2 24
21 3 20 1 Recepts - Exterior 360 ///////// 1860 ///////// 1500 EUH-3 - LVL 2 STAIRWELL 2 20 2 22
19 20 1 SPARE 1000 ///////// ///////// 1000 --- --- --- 2 20
17 3 20 1 Rcpts - Lev 2,3 corr 720 ///////// ///////// 1000 EUH-1 - ROOM 94 2 20 2 18
15 2 20 1 Fire Alarm Circuit 500 ///////// 1500 ///////// 1000 --- --- --- 2 16
13 3 20 1 Rcpts - Lev 1 W corr,stor,mech 540 1540 ///////// ///////// 1000 EUH-1 - ROOM 95 2 20 2 14
11 3 20 1 Rcpts - Lev 1 E corr,stor,mech 360 ///////// ///////// 388 28 LTG - EXTERIOR, BLDG MNTD 1 20 1 12
9 20 1 SPARE ///////// 1000 ///////// 1000 -- -- -- 2 10
7 1 20 1 Lights-Utility-Storage Level 1 E. 60 1060 ///////// ///////// 1000 EUH-1 - ROOM 101 2 20 2 8
5 1 20 1 Lights-Utility-Storage Level 1 W. 60 ///////// ///////// 2486 2426 -- -- -- 2 6
3 1 20 1 Lights- Level 1,2,3 stairs 100 ///////// 2526 ///////// 2426 -- -- -- 2 4
1 1 20 1 Lights- Level 1,2,3 corridor 168 2594 ///////// ///////// 2426 DBP-1 - ROOM 94 3 30 2 2
NO. CODE TRIP POLE DESCRIPTION MISC REC LITE VA A B C VA LITE REC MISC DESCRIPTION POLE TRIP CODE NO.
CKT CB LOAD DESIGNATION LOAD PHASES LOAD LOAD DESIGNATION CB CKT
AIC RATING:42,000 MAINS:200/3 4=(KITCHEN EQUIPMENT NEC 220.56)
PANEL:HP BUS (AMPS):200 3=(RECEPTACLES NEC 220.44)
JOB:Haymeadow PHASE AND WIRE:3PH,4W 2=(NON-CONTINUOUS LOAD NEC 220.14)
DATE:3/3/2023 PANEL VOLTAGE:208/120V CKT CODE: 1=(CONTINUOUS LOAD NEC 210.19(A)
MIN 20A CKTS 1.33
MIN 15A CKTS 1.77
AMPACITY: 26.58
LOAD @3VA/SF: 3189
UNIT SF: 1063 (Largest Unit, Worst-case Typical)
Minimum Number Branch Circuits Required
PANEL:Typical Dwelling Unit (2BR)
ISSUE DATE:3.3.23 FEEDER DEMAND AMPS See Dwelling Unit Load Calculations
BY:CT FEEDER DEMAND KVA
BASED ON SQUARE D HOMELINE LOADCENTER 3-TIER SERIES RATED SYSTEM - LABEL PER NEC 240.86B
PROVIDE ALL CIRCUIT BREAKERS AS APPROVED BY THE AHJ.
** - PROVIDE 20A2P BREAKER FOR UNITS WITH EWH-1 (4000W), 2BR TYPE 6
* - PROVIDE GFCI DEVICES IN KITCHEN PER NEC 210.8(A)(6 AND NEC 406.11 REQUIREMENTS responsible to perform all work in accordance with 2020 NEC requirements.
GFCI - GROUND-FAULT CIRCUIT INTERRUPTER PER NEC 210.8(A)(1). (MAY BE LOCAL GFCI DEVICES)with 2020 NEC 210 and NEC 210.52 requirements. Contractor shall be
AFCI - ARC-FAULT CIRCUIT INTERRUPTER CIRCUIT BREAKER PER 2017 NEC 210.12(B)Note: All branch circuiting and devices installed shall be in compliance
NOTES:>>ALL DEVICES INSTALLED SHALL COMPLY WITH 2017 NEC 406.11 REQUIREMENTS<<See Dwelling Unit Load Calculations
TOTAL 22035 23396 CONNECTED KVA 45.4
29 AFCI 15 1 SPARE 0 ///////// SPARE 1 15 AFCI 30
27 AFCI 15 1 SPARE ///////// 3000 3000 --- --- --- 28
25 AFCI 15 1 SPARE 3000 ///////// 3000 EWH-2 2 30 **26
23 --- --- (FUTURE)///////// 4503 4503 --- --- --- AFCI 24
21 100 2 PV SYSTEM CONNECTION 4503 ///////// 4503 1 VTAC UNIT (HEATER CKT) 2 45 AFCI 22
19 AFCI 15 1 SPARE ///////// 2486 2486 --- --- --- 20
17 AFCI 15 1 SPARE 2486 ///////// 2486 1 VTAC UNIT 2 35 18
15 15 1 DCP-1 168 ///////// 4168 4000 PROVIDE 4-WIRE CONNECTION --- ---16
13 AFCI 15 1 REFRIGERATOR 1 696 4696 ///////// 4000 1 ELEC RANGE OVEN 2 50 14
11 AFCI 20 1 MICROWAVE 1 1800 ///////// 4300 2500 PROVIDE 4-WIRE CONNECTION --- --- 12
9 *20 1 SMALL APPLIANCE 2 1500 4000 ///////// 2500 1 CLOTHES DRYER 2 30 10
7 *20 1 SMALL APPLIANCE 2 1500 ///////// 3000 1500 1 LAUNDRY CIRCUIT 1 20 GFCI 8
5 AFCI 15 1 GENERAL LIGHTING 1075 2275 ///////// 1200 1 DISHWASHER 1 20 GFCI 6
3 AFCI 15 1 GENERAL LIGHTING 1075 ///////// 1939 864 1 GARBAGE DISPOSAL 1 20 GFCI 4
1 AFCI 15 1 GENERAL LIGHTING 1075 1075 ///////// 1 BATHROOM CIRCUIT 1 20 GFCI 2
NO. CODE TRIP POLE DESCRIPTION MISC REC LITE VA A B VA LITE REC MISC DESCRIPTION POLE TRIP CODE NO.
CKT CB LOAD DESIGNATION LOAD PHASES LOAD LOAD DESIGNATION CB CKT
AIC RATING:22,000 MAINS:MLO ** - COMPLY WITH NEC 210.7(B) REQUIREMENTS
PANEL:Typical Dwelling Unit (2BR)BUS (AMPS):125 * - GFCI DEVICES PER 210.8(B)(6) & NEC 406.11
JOB:Haymeadow PHASE & WIRE:1PH 3W GFCI= SEE NOTES BELOW
DATE:3/3/2023 PANEL...120/208 CKT CODE: AFCI= SEE NOTES BELOW
NOTE: CONDUCTORS SHOWN ARE COPPER UNLESS NOTED OTHERWISE.
DBP-1 BOOSTER PUMP 30A3P 20.2 7,277 208 3 30A3P W/30A FUSES (3#10;#10GND) 3/4"C
DCP-1 DOMESTIC RECIRC. PUMP 15A1P 1.4 168 120 1 MOTOR RATED SWITCH (2#12;#12GND) 3/4"C
EUH-2 & 3 ELECTRIC UNIT HEATER 20A2P 14.4 3,000 208 1 - (3#12;#12GND) 3/4"C DISCONNECT IS INCLUDED WITH UNIT
EUH-1 ELECTRIC UNIT HEATER 20A2P 9.6 2,000 208 1 - (3#12;#12GND) 3/4"C DISCONNECT IS INCLUDED WITH UNIT
VTAC-2 CKT 2 VERTICAL TERMINAL HEAT PUMP (HEATING CKT) 45A2P 43.3 9,006 208 1 60A2P FUSED DISC. (3#6;#10GND) 3/4"C FUSE PER MANUFACTURER REQUIREMENTS.
VTAC-2 CKT 1 VERTICAL TERMINAL HEAT PUMP 35A2P 23.9 4,971 208 1 60A2P FUSED DISC. (3#8;#10GND) 3/4"C FUSE PER MANUFACTURER REQUIREMENTS.
VTAC-1 VERTICAL TERMINAL HEAT PUMP 50A2P 48.3 10,046 208 1 60A2P FUSED DISC. (3#6;#10GND) 3/4"C FUSE PER MANUFACTURER REQUIREMENTS.
EF-1 EXHAUST FAN 20A1P 0.1 8 120 1 MOTOR RATED SWITCH (2#12;#12GND) 3/4"C
KEY ITEM CB AMPS WATTS VOLT PH. DISCONNECT FEEDER NOTES
EQUIPMENT SCHEDULE
PANEL:TYPICAL GARAGE PANEL G*
ISSUE DATE:11.14.2022 FEEDER DEMAND AMPS 50.7
BY:CT FEEDER DEMAND KVA 12.2
2. CONTROL WIRING FOR HVAC EQUIPMENT BY MECHANICAL CONTRACTOR - NIC CONN.KVA (CODE 4)0.0
TIMECLOCK OFF OPERATION.CONN.KVA (CODE 3)0.2
1. ROUTE EXTERIOR LIGHTS THROUGH PHOTOCELL/TIMECLOCK FOR PHOTOCELL ON/CONN.KVA (CODE 2)3.6
NOTES:CONN.KVA (CODE 1)6.7
TOTAL 5474 5008 CONNECTED KVA 10.5
19 20 1 SPARE ///////// 0 SPARE 1 20 20
17 20 1 SPARE 0 ///////// SPARE 1 20 18
15 20 1 SPARE ///////// 0 SPARE 1 20 16
13 20 1 SPARE 0 ///////// SPARE 1 20 14
11 20 1 SPARE ///////// 0 SPARE 1 20 12
9 20 1 SPARE 0 ///////// SPARE 1 20 10
7 20 1 SPARE ///////// 1500 1500 --- --- --- 2 8
5 2 20 1 DOOR OPENER 600 2100 ///////// 1500 EUH-2 2 20 2 6
3 3 20 1 RECEPTS 180 ///////// 3508 3328 --- --- --- 1 4
1 1 20 1 LIGHTING 46 3374 ///////// 3328 EV CHARGING STATION 2 40 1 2
NO. CODE TRIP POLE DESCRIPTION MISC REC LITE VA A B VA LITE REC MISC DESCRIPTION POLE TRIP CODE NO.
CKT CB LOAD DESIGNATION LOAD PHASES LOAD LOAD DESIGNATION CB CKT
AIC RATING:10,000 MAINS:MLO 4=(KITCHEN EQUIPMENT NEC 220.56)
PANEL:TYPICAL GARAGE PANEL G*BUS (AMPS):100 3=(RECEPTACLES NEC 220.44)
JOB:Haymeadow PHASE & WIRE:1PH 3W 2=(NON-CONTINUOUS LOAD NEC 220.14)
DATE:11/15/2022 PANEL VOLTAGE:120/240 CKT CODE: 1=(CONTINUOUS LOAD NEC 210.19(A)
2 VE CHANGES 03/03/2023
MIN 20A CKTS 0.84
MIN 15A CKTS 1.12
AMPACITY: 16.85
LOAD @3VA/SF: 2022
UNIT SF: 674 (Largest Unit, Worst-case Typical)
Minimum Number Branch Circuits Required
PANEL:Typical Dwelling Unit (1BR)
ISSUE DATE:3.3.23 FEEDER DEMAND AMPS See Dwelling Unit Load Calculations
BY:CT FEEDER DEMAND KVA
BASED ON SQUARE D HOMELINE LOADCENTER 3-TIER SERIES RATED SYSTEM - LABEL PER NEC 240.86B
PROVIDE ALL CIRCUIT BREAKERS AS APPROVED BY THE AHJ.
* - PROVIDE GFCI DEVICES IN KITCHEN PER NEC 210.8(A)(6 AND NEC 406.11 REQUIREMENTS responsible to perform all work in accordance with 2020 NEC requirements.
GFCI - GROUND-FAULT CIRCUIT INTERRUPTER PER NEC 210.8(A)(1). (MAY BE LOCAL GFCI DEVICES)with 2020 NEC 210 and NEC 210.52 requirements. Contractor shall be
AFCI - ARC-FAULT CIRCUIT INTERRUPTER CIRCUIT BREAKER PER 2017 NEC 210.12(B)Note: All branch circuiting and devices installed shall be in compliance
NOTES:>>ALL DEVICES INSTALLED SHALL COMPLY WITH 2017 NEC 406.11 REQUIREMENTS<<See Dwelling Unit Load Calculations
TOTAL 21871 24083 CONNECTED KVA 46.0
29 AFCI 15 1 SPARE 0 ///////// SPARE 1 15 AFCI 30
27 AFCI 15 1 SPARE ///////// 2000 2000 --- --- --- 28
25 AFCI 15 1 SPARE 2000 ///////// 2000 EWH-1 2 20 26
23 --- --- (FUTURE)///////// 4503 4503 SPARE --- --- AFCI 24
21 100 2 PV SYSTEM CONNECTION 4503 ///////// 4503 1 SPARE 2 45 AFCI 22
19 AFCI 15 1 SPARE ///////// 5023 5023 --- --- --- 20
17 AFCI 15 1 SPARE 5023 ///////// 5023 1 VTAC UNIT 2 50 18
15 15 1 DCP-1 168 ///////// 4168 4000 PROVIDE 4-WIRE CONNECTION --- ---16
13 AFCI 15 1 REFRIGERATOR 1 696 4696 ///////// 4000 1 ELEC RANGE OVEN 2 50 14
11 AFCI 20 1 MICROWAVE 1 1800 ///////// 4300 2500 PROVIDE 4-WIRE CONNECTION --- --- 12
9 *20 1 SMALL APPLIANCE 2 1500 4000 ///////// 2500 1 CLOTHES DRYER 2 30 10
7 *20 1 SMALL APPLIANCE 2 1500 ///////// 3000 1500 1 LAUNDRY CIRCUIT 1 20 GFCI 8
5 AFCI 15 1 GENERAL LIGHTING 225 1425 ///////// 1200 1 DISHWASHER 1 20 GFCI 6
3 AFCI 15 1 GENERAL LIGHTING 225 ///////// 1089 864 1 GARBAGE DISPOSAL 1 20 GFCI 4
1 AFCI 15 1 GENERAL LIGHTING 225 225 ///////// 1 BATHROOM CIRCUIT 1 20 GFCI 2
NO. CODE TRIP POLE DESCRIPTION MISC REC LITE VA A B VA LITE REC MISC DESCRIPTION POLE TRIP CODE NO.
CKT CB LOAD DESIGNATION LOAD PHASES LOAD LOAD DESIGNATION CB CKT
AIC RATING:22,000 MAINS:MLO ** - COMPLY WITH NEC 210.7(B) REQUIREMENTS
PANEL:Typical Dwelling Unit (1BR)BUS (AMPS):125 * - GFCI DEVICES PER 210.8(B)(6) & NEC 406.11
JOB:Haymeadow PHASE & WIRE:1PH 3W GFCI= SEE NOTES BELOW
DATE:3/3/2023 PANEL...120/208 CKT CODE: AFCI= SEE NOTES BELOW
2 E3/3/2023