HomeMy WebLinkAbout20230222 BLDG. DEPT.RESPONSE AND REVISIONS_BLDG CGENERAL NOTES
1. LIVE LOADS USED IN DESIGN:
A. ROOF (SNOW) 50 PSF
B. RESIDENTIAL 40 PSF
C. BALCONIES 125 PSF (INCLUDES HOT TUB LOADING)
D. RISK CATEGORY II
SEISMIC FACTOR IE 1
SNOW FACTOR IS 1
E. WIND
WIND SPEED, Vult 115 MPH (ULTIMATE)
WIND SPEED, Vasd 90 MPH (ASD)
EXPOSURE C
INTERNAL PRESSURE COEFFICIENT (GCpi) +/-0.18
WIND PRESSURE FOR COMPONENTS AND CLADDING:
ZONE 1, ROOF (TYPICAL) -32.2 PSF
ZONE 2, ROOF (EDGES, RIDGES, HIPS) -50.4 PSF
ZONE 3, ROOF (CORNERS) -68.7 PSF
ZONE 4, WALL (TYPICAL) +/-21.9 PSF
ZONE 5, WALL (CORNERS) -40.3/+21.9 PSF
PARAPETS (TYPICAL) -51/+22.2 PSF
PARAPETS (CORNERS) -69.5/+22.2 PSF
C & C NOTES:
1. THE PRESSURES LISTED ARE IN ACCORDANCE IBC AND ASCE 7 AND THE DESIGN
FORCES USED BY THE SUBCONTRACTOR FOR HIS SPECIFIC APPLICATION ARE HIS
RESPONSIBILITY.
2. WIND PRESSURES ARE ULTIMATE DESIGN LEVEL.
3. PRESSURES INDICATED ARE BASED ON A 10 SF EFFECTIVE WIND AREA.
4. REFERENCE ASCE 7 FOR ZONE DEFINITIONS AND EXTENT OF ZONES.
5. SUBMIT DESIGN CALCULATIONS PREPARED BY COLORADO LICENSED
PROFESSIONAL
ENGINEER FOR ANY DESIRED MODIFICATION OF THE STATED PRESSURES.
F. SNOW
GROUND SNOW LOAD Pg 50 PSF
FLAT ROOF SNOW LOAD Pf 50 PSF
SNOW EXPOSURE FACTOR Ce 1
THERMAL FACTOR Ct 1
H. LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE.
I. CODE USED IN DESIGN: INTERNATIONAL BUILDING CODE, 2015 EDITION WITH
2. DEFERRED SUBMITTAL
A. DEFERRED SUBMITTALS PER SECTION 107.3.4.1 SHALL BE SUBMITTED TO THE
BUILDING OFFICIAL AND THE DESIGN PROFESSIONALS AND REVIEWED PRIOR TO
INSTALLATION.
B. DEFERRED SUBMITTALS ARE:
1. PREFABRICATED ROOF TRUSSES
2. STAIRS
C. ALL DEFERRED SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF THE
LICENSED PROFESSIONAL ENGINEER RESPONSIBLE FOR THE PREPARATION OF
THESE DOCUMENTS.
3. TESTING, INSPECTIONS AND OBSERVATIONS:
A. THE STRUCTURAL ENGINEER DOES NOT PROVIDE INSPECTIONS OF CONSTRUCTION.
STRUCTURAL ENGINEER MAY MAKE PERIODIC OBSERVATIONS OF THE
CONSTRUCTION; SUCH OBSERVATIONS SHALL NOT REPLACE REQUIRED
INSPECTIONS BY THE GOVERNING AUTHORITIES OR SERVE AS "SPECIAL
INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL
BUILDING CODE.
B. THE FOLLOWING WORK SHALL BE INSPECTED BY THE SPECIAL INSPECTOR UNLESS
SPECIFICALLY WAIVED BY THE BUILDING OFFICIAL.
1. SOIL PREPARATION
a. EARTHWORK EXCAVATION, PLACEMENT AND COMPACTION OF FILL
AND IN-PLACE DRY DENSITY OF THE COMPACTED FILL FOR
CONFORMANCE WITH THE APPROVED REPORT.
2. CONCRETE CONSTRUCTION
a. PERIODIC INSPECTION OF REINFORCING STEEL, INCLUDING
PRESTRESSING TENDONS AND PLACEMENT.
b. CONTINUOUS INSPECTION OF PLACEMENT OF SHEAR REINFORCEMENT.
c. PERIODIC VERIFICATION OF USE OF REQUIRED DESIGN MIX.
d. CONTINUOUS INSPECTION AT THE TIME FRESH CONCRETE IS SAMPLED
TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND
AIR CONTENT TESTS AND DETERMINE THE TEMPERATURE OF THE
CONCRETE.
e. CONTINUOUS INSPECTION OF CONCRETE PLACEMENT FOR PROPER
APPLICATION TECHNIQUES.
f. PERIODIC INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
g. CONTINUOUS INSPECTION OF APPLICATION OF PRESTRESS FORCES.
h. CONTINUOUS INSPECTION OF GROUTING OF BONDED PRESTRESSING
TENDONS IN THE SEISMIC-FORCE-RESISTING SYSTEM.
i. PERIODIC VERIFICATION OF IN-SITU CONCRETE STRENGTH PRIOR TO
STRESSING OF TENDONS IN POST TENSIONED CONCRETE AND PRIOR TO
REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL
SLABS.
3. STEEL CONSTRUCTION -COMPLY WITH AISC 360, CHAPTER N.
a. ALL WELDING SHALL RECEIVE CONTINUOUS SPECIAL INSPECTION
EXCEPT THE FOLLOWING:
1. WELDING DONE IN AN APPROVED FABRICATOR'S SHOP IN
ACCORDANCE WITH SECTION 1704.3.
b. THE SPECIAL INSPECTOR NEED NOT BE CONTINUOUSLY PRESENT
DURING WELDING OF THE FOLLOWING ITEMS, PROVIDED THE MATERIALS,
WELDING PROCEDURES AND QUALIFICATIONS OF WELDERS ARE
VERIFIED PRIOR TO THE START OF WORK; PERIODIC INSPECTIONS ARE
MADE OF WORK IN PROGRESS; AND A VISUAL INSPECTION OF ALL WELDS
IS MADE PRIOR TO COMPLETION OR PRIOR TO SHIPMENT OF SHOP
WELDING.
1. WHILE THE WORK IS IN PROGRESS, THE SPECIAL INSPECTOR
SHALL DETERMINE THAT THE REQUIREMENTS FOR BOLTS, NUTS,
WASHERS AND PAINT, BOLTED PARTS AND INSTALLATION AND
TIGHTENING IN SUCH STANDARDS ARE MET. FOR BOLTS
REQUIRING PRETENSIONING, THE SPECIAL INSPECTOR SHALL
OBSERVE THE PREINSTALLATION TESTING AND CALIBRATION
PROCEDURES WHEN SUCH PROCEDURES ARE REQUIRED BY THE
INSTALLATION METHOD OR BY PROJECT PLANS OR
SPECIFICATIONS; DETERMINE THAT ALL PLIES OF CONNECTED
MATERIALS HAVE BEEN DRAWN TOGETHER AND PROPERLY
SNUGGED AND MONITOR THE INSTALLATION OF BOLTS TO VERIFY
THAT THE SELECTED PROCEDURE FOR INSTALLATION IS
PROPERLY USED TO TIGHTEN BOLTS. FOR JOINTS REQUIRED TO
BE TIGHTENED ONLY TO THE SNUG-TIGHT CONDITION, THE
SPECIAL INSPECTOR NEED ONLY VERIFY THAT THE CONNECTED
MATERIALS HAVE BEEN DRAWN TOGETHER AND PROPERLY
SNUGGED.
2. MONITORING OF BOLT INSTALLATION FOR PRETENSIONING IS
PERMITTED TO BE PERFORMED ON A PERIODIC BASIS WHEN
USING THE TURN-OF-NUT METHOD WITH MATCHMARKING
TECHNIQUES, THE DIRECT TENSION INDICATOR METHOD OR THE
ALTERNATE DESIGN FASTENER (TWIST-OFF BOLT) METHOD.
JOINTS DESIGNATED AS SNUG TIGHT NEED TO BE INSPECTED
ONLY ON A PERIODIC BASIS.
4. FOUNDATIONS
A. MAXIMUM SOIL DESIGN PRESSURE 2,500 PSF
B. CONTRACTOR TO FOLLOW ALL RECOMMENDATIONS IN SOILS REPORT
NO. 21.5057 BY CESARE, INC. DATED JANUARY 31, 2022.
C. ALL FOOTING BEARING ELEVATIONS SHOWN ARE ASSUMED. EXACT BEARING
ELEVATIONS SHALL BE VERIFIED IN THE FIELD WITH ACTUAL CONDITIONS BY
CONTRACTOR WITH APPROVAL OF SOILS ENGINEER AND ALL BOTTOMS OF FOOTINGS
SHALL BE A MINIMUM OF 48" BELOW EXTERIOR GRADE.
D. ALL FOOTINGS ARE TO BE PLACED ON 18 INCHES OF PROPERLY COMPACTED
BACKFILL, APPROVED BY THE SOILS ENGINEER. BACKFILL SHALL BE COMPACTED
TO 95% (MINIMUM) MODIFUED PROCTOR DENSITY PER ASTM D1551 UNLESS
OTHERWISE RECOMMENDED IN THE SOILS REPORT. IF SOFT SPOTS ARE
ENCOUNTERED REMOVE SOIL AND RECOMPACT WITH APPROVED FILL (RE: SOIL
REPORT FOR DESCRIPTION OF BEARING SOIL).
E. CONTRACTOR SHALL BACKFILL EQUALLY ON EACH SIDE OF FOUNDATION WALLS IN 12
INCH MAXIMUM VERTICAL LIFTS OR AS RECOMMENDED IN THE SOILS REPORT. REFER
TO SOILS REPORT FOR BACKFILL MATERIAL.
F. NO BACKFILLING SHALL BE PLACED AGAINST LOWER LEVEL WALLS UNTIL THE LOWER
LEVEL FLOOR AND MAIN LEVEL FLOOR ARE IN PLACE AND PROPERLY ANCHORED.
CONCRETE SLABS SHALL BE PROPERLY CURED.
G. CENTER ALL FOOTINGS (DRILLED PIERS) UNDER WALLS, COLUMNS OR GRID LINES
UNLESS NOTED OTHERWISE ON PLANS.
H. CONTRACTOR TO PROVIDE, AT HIS EXPENSE, FIELD DENSITY TESTS ON COMPACTED
FILL UNDER FOOTINGS AND INTERIOR SLABS-ON-GRADE.
I. NOTIFY SOILS ENGINEER WHEN EXCAVATION IS COMPLETED SO THAT CONDITIONS MAY
BE INSPECTED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE.
J. FOR SOIL DRAINAGE REQUIREMENTS REFER TO SOILS REPORT AND CIVIL DRAWINGS.
5. SLAB ON GRADE
A. THE PREPARATION OF THE SUBGRADE FOR THE SLAB ON GRADE SHALL BE IN STRICT
ACCORDANCE WITH THE PROJECT SOILS REPORT REFERENCED ABOVE. THE
CONTRACTOR SHALL DIRECT QUESTIONS REGARDING THE SUBGRADE PREPARATION
REQUIREMENTS TO THE GEOTECHNICAL ENGINEER. 12 INCHES OF OVER-EXCAVATION
REQUIRED.
B. MOVEMENT OF THE SLAB ON GRADE MAY CAUSE DAMAGE TO ANYTHING CONNECTED
TO BOTH THE SLAB AND OTHER PORTIONS OF THE SUPERSTRUCTURE. ISOLATION
DETAILS FOR PARTITION WALLS, BASEBOARDS, PIPING AND OTHER ITEMS MAY BE
REQUIRED. REFER TO THE APPROPRIATE DRAWINGS OR CONSULT WITH THE
RESPONSIBLE MEMBER OF THE DESIGN TEAM PRIOR TO CONNECTING ITEMS TO BOTH
THE SLAB ON GRADE AND OTHER PORTIONS OF THE SUPERSTRUCTURE.
6. CONCRETE
A. ALL CAST-IN-PLACE CONCRETE SHALL BE MADE WITH TYPE I/II PORTLAND CEMENT,
STONE AGGREGATE AND SHALL SATISFY THE FOLLOWING REQUIREMENTS:
CONCRETE ITEM F'C MIX TYPE MAX W/C RATIO % AIR REQ.
FOOTINGS 3000 psi STD --- ---
FOUNDATION WALLS 4000 psi STD --- ---
INTERIOR SLABS ON GRADE 4000 psi STD 0.45 ---
EXTERIOR CONCRETE (++) 4500 psi STD 0.45 5%-8%
+ FOR ALL CONCRETE SUBJECT TO SULFATE ATTACK OR POSSIBLE CONTACT WITH
ROAD SALTS W/C RATIO SHALL NOT EXCEED 0.4.
++ MAXIMUM SLUMP SHALL NOT EXCEED 4".
B. THE MODULUS OF ELASTICITY OF ALL CONCRETE SHALL EXCEED W 33 F'C (OR
57,000 F'C NORMAL WEIGHT CONCRETE). GENERAL CONTRACTOR TO PROVIDE THE
ENGINEER OF RECORD WITH MODULUS OF ELASTICITY TEST RESULTS.
C. CALCIUM CHLORIDE SHALL NOT BE USED. POZZOLANS SHALL NOT BE USED WITHOUT
PRIOR APPROVAL BY ENGINEER OF RECORD. IF APPROVED, POZZOLANS SHALL BE
LIMITED TO (10) % OF CEMENT CONTENT BY WEIGHT IN ELEVATED STRUCTURAL
SLABS AND __(25)__% IN ALL OTHER STRUCTURAL ELEMENTS. IF CONCRETE SUPPLIER
PROPOSES USE OF POZZOLANS HE SHALL PROVIDE OWNER WITH LETTER INDICATING
COST REDUCTION AT TIME OF BID.
D. CONTRACTOR SHALL SAWCUT OR TROWELCUT JOINTS IN SLABS ON GRADE. JOINTS
SHALL BE SPACED 15 FEET O.C. AND SAWCUT OR TROWELCUT 1/4 OF SLAB DEPTH X
3/16" WIDE WITHIN 12 HOURS AFTER POURING. CARRY ALL SLAB REINFORCEMENT
THROUGH JOINT.
F. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCE
WITH ACI BUILDING CODE 318 LATEST EDITION, UNLESS NOTED OTHERWISE. USE
STANDARD HOOKS FOR DOWELS UNLESS NOTED OTHERWISE. ALL EXPOSED EDGES OF
CONCRETE WORK SHALL HAVE 3/4 INCH CHAMFER.
7. REINFORCEMENT
A. ALL REINFORCING SHALL BE HIGH-STRENGTH DEFORMED BARS CONFORMING TO ASTM
A615, GRADE 60 EXCEPT TIES, STIRRUPS AND PLATE ANCHORS WHICH SHALL BE
DEFORMED BARS, ASTM DESIGNATION A615, GRADE 40 OR ASTM A706 GRADE 60.
B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 GRADE 65 AND SHALL BE
LAPPED ONE FULL MESH AT SIDE AND END SPLICES AND WIRED TOGETHER.
C. POLYPROPYLENE FIBER REINFORCING SHALL HAVE FIBER LENGTH COORDINATE WITH
AGGREGATE SIZE AS PER MANUFACTURER'S RECOMMENDATIONS. AMOUNT OF FIBERS
SHALL BE A MINIMUM OF 1.5 LBS/YRD3 OF CONCRETE OR THE AMOUNT RECOMMENDED
BY THE MANUFACTURER WHICHEVER IS GREATER.
D. REINFORCEMENT CLEAR COVER PROTECTION MILDLY REINFORCED UNLESS NOTED
OTHERWISE:
1. CONCRETE POURED AGAINST EARTH 3"
2. CONCRETE POURED IN FORMS (EXPOSED TO WEATHER OR EARTH)
BARS #5 AND SMALLER 1-1/2"
BARS LARGER THAN #5 2"
3. COLUMNS AND BEAMS (TIE BARS) 1-1/2"
4. SLABS AND WALLS (NOT EXPOSED TO WEATHER) 3/4"
F. REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITH
OF ACI 318, LATEST EDITION.
G. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR
AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES, WHERE PERMITTED, SHALL
BE A MINIMUM OF 48 BAR DIAMETERS FOR #6 BARS AND SMALLER AND SHALL BE A
MINIMUM OF 80 BAR DIAMETERS FOR #7 AND #8 REINFORCEMENT UNLESS NOTED
OTHERWISE. MAKE ALL BARS CONTINUOUS AROUND CORNERS.
H. PLACE TWO #5 (PER 8" THICKNESS) WITH 2'-0" PROJECTION AROUND ALL OPENINGS IN
CONCRETE WALLS, SLABS, AND BEAMS. ALSO PROVIDE TWO #5 X 4'-0" DIAGONALLY AT
EACH CORNER.
I. CONTINUOUS TOP AND BOTTOM BARS IN WALLS AND BEAMS SHALL BE SPLICED AS
FOLLOWS: TOP BARS AT MIDSPAN, BOTTOM BARS OVER SUPPORTS.
K. PROVIDE TEMPORARY BRACING AND PRECAUTIONS NECESSARY TO COMPLY WITH ALL
STEEL ERECTION STANDARDS AND TO WITHSTAND ALL CONSTRUCTION AND/OR
LATERAL LOADS UNTIL ALL FIELD CONNECTIONS ARE COMPLETED AND PERMANENT
LATERAL SYSTEMS AND DECKS ARE IN PLACE.
L. STEEL FABRICATOR SHALL NOT RECEIVE ADDITIONAL COMPENSATION FOR SHOP
DRAWING TIME FOR ANY REVISIONS TO ERECTION DRAWINGS NOR FOR ANY REVISIONS
TO PIECE DRAWINGS PRIOR TO ENGINEER'S APPROVAL OF ERECTION DRAWINGS.
M. UNLESS NOTED OTHERWISE, WHENEVER MASONRY RESTS ON STEEL BEAMS WITH
FLANGES NARROWER THAN ACTUAL MASONRY THICKNESS, WELD 1/4" THICK
CONTINUOUS PLATE TO BEAM FLANGE. WIDTH OF PLATE TO BE 1/2" NARROWER THAN
MASONRY THICKNESS.
9. NON-SHRINK GROUT
A. NON-SHRINK GROUT SHALL BE PROVIDED:
1. BETWEEN COLUMN BASES AND CONCRETE OR MASONRY SUPPORTS.
2. BETWEEN BEAM BEARING PLATES AND CONCRETE OR MASONRY SUPPORTS.
3. GROUT SHALL BE COMPLETE AND HAVE A MINIMUM COMPRESSIVE STRENGTH
OF 6000 PSI PRIOR TO ADDING BUILDING LOADS ABOVE.
10. WOOD
A. ALL FRAMING AND TRUSS LUMBER SHALL BE DRY DOUGLAS FIR, LARCH, GRADED BY
WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL
BUILDING CODE AS FOLLOWS:
2" THICK -4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 700 PSI
2" TO 4" THICK -6" AND WIDER NO. 2 Fb = 900 PSI
5" THICK -5" AND WIDER NO. 1 Fb = 1350 PSI
NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETITIVE USES PRIOR
TO ALLOWABLE STRESS INCREASES.
B. WHEN PRESERVATIVE TREATED LUMBER IS REQUIRED BY CODE ALL CONNECTIONS AND
NAILING SHALL BE ADEQUATELY GALVANIZED (DOUBLE DIPPED OR BETTER).
C. TREATED SILL PLATE LUMBER MAY BE HEM-FIR, STRUCTURAL #1 GRADE.
D. PROVIDE METAL CROSS BRIDGING NOT OVER 8' ON CENTER FOR ALL 2X WOOD JOISTS.
SOLID BLOCKING BETWEEN ALL JOISTS AT ALL SUPPORTS AND ENDS OF CANTILEVERS
IS REQUIRED.
E. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULE
TABLE 2304.10.1 UNLESS NOTED OTHERWISE.
F. LAMINATED BEAMS
1. ALL LAMINATED MEMBERS SHALL BE FABRICATED OF DOUGLAS FIR LARCH AT
LESS THAN 12 PERCENT MOISTURE CONTENT IN ACCORDANCE WITH WCLIB. ALL
SIZES SHOWN ARE NET.
2. LAMINATED MEMBER SHALL BE DETAILED AND FABRICATED IN ACCORDANCE
WITH THE STANDARD SPECIFICATIONS FOR THE DESIGN AND FABRICATION OF
STRUCTURAL GLUE LAMINATED TIMBER, LATEST EDITION AS PUBLISHED BY AITC.
3. PROVIDE UNITS CONFORMING TO AITC 117, 24FV8, D.F. FOR CONTINUOUS
MEMBERS AND CANTILEVERS AND 24FV4, D.F. FOR SIMPLE SUPPORT MEMBERS.
MEMBERS SHALL BE DESIGNED WITH ZERO CAMBER WITH TOP SURFACE
CLEARLY STAMPED ON EACH MEMBER.
G. PLYWOOD DECK AND/OR ORIENTED STRAND BOARD.
1. PANEL THICKNESS SHALL BE AS SHOWN ON THE DRAWING. APPLICATION SHALL
BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE AMERICAN PLYWOOD
ASSOCIATION.
2. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE-TRADEMARK OF THE
AMERICAN PLYWOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF
U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELS
WHICH HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE
WEATHER SHALL BE OF THE EXTERIOR TYPE.
3. FOR FLOORING USE 3/4" T&G STURD-I-FLOOR SHEATHING GLUED AND NAILED
WITH 10D NAILS AT 6" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
4. FOR ROOF USE 5/8" (40/20 SPAN RATING) EXPOSURE I SHEATHING NAILED
WITH 10D NAILS AT 4" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
5. EXTERIOR WALLS SHALL HAVE ONE LAYER OF 1/2" EXPOSURE I PLYWOOD OR
OSB SHEATHING NAILED WITH 8d NAILS AT 6" ON CENTER ALONG PANEL
EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES
SHALL BE BLOCKED.
6. FLOORS AND ROOF SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN
PERPENDICULAR TO SUPPORTS WITH END JOINTS STAGGERED.
7. INSTALL SUITABLE EDGE SUPPORT BY USE OF PLYCLIPS, TONGUE AND
GROOVE PANELS OR SOLID WOOD BLOCKING SUPPORTS.
H. LAMINATED VENEER LUMBER MEMBERS SHALL HAVE THE FOLLOWING STRESS
CAPACITIES: FB = 2800 PSI, E = 2,000,000 PSI, FC = 750 PSI, FV = 285 PSI.
BUILT UP MEMBERS SHALL BE CONNECTED IN ACCORDANCE WITH MANUFACTURERS'
RECOMMENDATIONS. CONTRACTOR SHALL HAVE THE OPTION OF USING 3 1/2" OR
5 1/4" WIDE MEMBERS.
I. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO FULFILL STRESS
REQUIREMENTS AND/OR LOADS NOTED ON DRAWINGS. SHOP DRAWINGS SHALL
INCLUDE CALCULATIONS AND BEAR THE STAMP OF A REGISTERED ENGINEER. PROVIDE
BRIDGING AND BLOCKING PER MANUFACTURER'S RECOMMENDATIONS UNLESS
OTHERWISE NOTED. PROVIDE CONSTRUCTION BRACING AS REQUIRED ERECTION NOTE:
CENTER WALL STUDS UNDER CENTER OF TRUSS LOCATIONS.
11. NON-STRUCTURAL ELEMENTS
A. ELEMENTS SUCH AS NON-BEARING PARTITIONS, ETC. ATTACHED TO AND/OR
SUPPORTED BY THE STRUCTURE SHALL TAKE INTO ACCOUNT DEFLECTIONS AND
OTHER STRUCTURAL MOVEMENTS.
B. FIRE PROTECTION FOR ALL STRUCTURAL PARTS SHALL BE PROVIDED AND SHALL MEET
ALL CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED BY THE
ARCHITECTURAL DRAWINGS. STRUCTURAL STEEL MEMBERS SHALL BE CONSIDERED
UNRESTRAINED UNLESS NOTED OTHERWISE.
12. GENERAL
A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS.
B. VERIFY ALL OPENINGS THROUGH FLOORS, ROOF AND WALLS WITH MECHANICAL AND
ELECTRICAL CONTRACTORS. VERIFICATION OF LOCATIONS, SIZES, LINTELS AND
REQUIRED CONNECTIONS ARE CONTRACTOR'S COMPLETE RESPONSIBILITY.
C. PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT OR OTHER
ITEMS TO BE ATTACHED TO THE STRUCTURE, ENGINEER'S APPROVAL OF CONNECTIONS
AND SUPPORTS SHALL BE OBTAINED. UNLESS SPECIFICALLY DETAILED ON
ARCHITECTURAL AND STRUCTURAL DRAWINGS, RESPECTIVE SUBCONTRACTOR
SHALL FURNISH ALL HANGERS, CONNECTIONS, ETC., REQUIRED FOR INSTALLATION OF
HIS ITEMS.
D. PROVIDE ALL EMBEDDED ITEMS IN STRUCTURE AS NOTED ON ARCHITECTURAL,
MECHANICAL, ELECTRICAL AND STRUCTURAL DRAWINGS. MISCELLANEOUS EMBEDDED
ITEMS AND ANCHOR BOLTS SHALL BE FURNISHED BY STEEL SUPPLIER AND INSTALLED
BY CONCRETE CONTRACTOR. STEEL SHALL FULFILL ASTM A36.
E. PROVIDE ASPHALTIC MASTIC-COATING ON ALL STEEL AND WOOD EXPOSED TO EARTH.
F. SUBMIT SHOP AND ERECTION DRAWINGS TO ENGINEER FOR REVIEW OF ALL CONCRETE
REINFORCING, STRUCTURAL STEEL, LAMINATED WOOD FRAMING MEMBERS AND WOOD
JOISTS. THE MANUFACTURING OR FABRICATION OF ANY ITEMS PRIOR TO WRITTEN
REVIEW OF SHOP DRAWINGS WILL BE ENTIRELY AT THE RISK OF THE CONTRACTOR.
SHOP DRAWINGS NOT REVIEWED AND STAMPED BY CONTRACTOR PRIOR TO
SUBMITTING WILL BE RETURNED AND NOT REVIEWED.
G. WATERPROOFING, VAPOR BARRIERS, WATERSTOP, ETC., SHALL BE AS SHOWN ON THE
ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS.
H. ALL MASONRY AND STONE VENEERS SHALL BE ATTACHED TO INTERIOR AND EXTERIOR
WALLS AS SPECIFIED IN SECTION 1405 OF THE INTERNATIONAL BUILDING CODE.
I. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD
CONDITIONS AND ARCHITECTURAL DRAWINGS.
J. PRE-MANUFACTURED STAIRS, HANDRAILS, AND GUARDRAILS NOTED ON PLAN SHALL
HAVE ALL ENGINEERING, DESIGN AND DETAILING PROVIDED BY STAIR DESIGNER AND
SHALL BE SUBMITTED FOR ARCHITECTS REVIEW BEARING THE SEAL OF A
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF COLORADO. STAIRS SHALL
BE DESIGNED TO SUPPORT A LIVE LOAD OF 100 PSF. SEE ARCHITECTURAL DRAWINGS
FOR ADDITIONAL REQUIREMENTS AND CRITERIA.
1. SINGLE PASS FILLET WELDS NOT EXCEEDING 5/16" IN SIZE.
2. WELDED SHEET STEEL FOR COLD FORMED STEEL FRAMING
MEMBERS SUCH AS STUDS AND JOISTS.
3. WELDING OF STAIRS AND RAILING SYSTEMS.
c. VERIFY WELD FILLER MATERIALS CONFORM TO AWS SPECIFICATIONS
AND MANUFACTURER'S CERTIFICATE OF COMPLIANCE IS REQUIRED.
d. VERIFY STRUCTURAL STEEL MATERIAL CONFORMS TO ASTM STANDARDS
SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS AND
MANUFACTURER'S CERTIFIED MILL TEST REPORTS.
e. PERIODIC VERIFICATION OF HIGH STRENGTH BOLTS, NUTS AND WASHERS
FOR CONFORMANCE TO ASTM STANDARDS SPECIFIED IN THE APPROVED
CONSTRUCTION DOCUMENTS AND MANUFACTURER'S CERTIFICATE OF
COMPLIANCE.
f. CONTINUOUS INSPECTION OF SLIP-CRITICAL CONNECTION WITH HIGH
STRENGTH BOLTS. PERIODIC INSPECTION OF BEARING TYPE
CONNECTORS WITH HIGH STRENGTH BOLTS.
8. STRUCTURAL STEEL
A. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT WIDE FLANGE BEAMS
WHICH SHALL CONFORM TO ASTM 992, (50 KSI) AND EXCEPT PIPE COLUMNS WHICH
SHALL CONFORM TO ASTM A53 AND TUBE COLUMNS TO ASTM A500, GRADE B, LATEST
EDITIONS. STEEL SUPPLIER MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION.
MISCELLANEOUS STRUCTURAL STEEL SHAPES SHALL CONFORM TO ASTM A36 UNLESS
NOTED OTHERWISE. MISCELLANEOUS EMBEDDED STEEL ITEMS SHALL BE A36 STEEL
UNLESS NOTED OTHERWISE.
B. ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHT
CONDITION. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM F1554, GR. 36 UNLESS
NOTED OTHERWISE.
C. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE
LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION."
D. EXCEPT WHERE DETAILED OTHERWISE, FABRICATOR SHALL SELECT STEEL
CONNECTIONS PER AISC "MANUAL OF STEEL CONSTRUCTION" (ASD), TABLE 11-A
AND/OR AISC "SIMPLE SHEAR CONNECTION MANUAL" WITH A325 N BOLTS (OR WELDED
EQUIVALENT) TO SUPPORT LOADS INDICATED ON THE STRUCTURAL DRAWINGS. WHEN
LOADS ARE NOT SHOWN, SELECT CONNECTION TO SUPPORT 60% THE TOTAL UNIFORM
LOAD CAPACITY PER AISC "MANUAL OF STEEL CONSTRUCTION" FOR EACH GIVEN BEAM
AND SPAN FOR NON-COMPOSITE MEMBERS.
SUBMIT DESIGN CALCULATIONS, BEARING THE STAMP AND SIGNATURE OF THE
PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO, AND
EMPLOYED BY THE STEEL FABRICATOR, FOR ALL CONNECTIONS NOT COMPLETELY
DETAILED ON THE STRUCTURAL DRAWINGS AND FOR ANY PROPOSED ALTERNATE
CONNECTION DETAILS.
E. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY
STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS-D1.1.
F. MINIMUM WELDS TO BE PER AISC TABLE J2.4 BUT NOT LESS THAN 3/16" CONTINUOUS
FILLET UNLESS NOTED OTHERWISE.
G. FOR ALL BEAM/COLUMN OR BEAM/BEAM CONNECTIONS, PROVIDE HORIZONTAL SHORT
SLOTS IN CONNECTION MEMBER ONLY (WT-SECTIONS, ANGLES OR SHEAR PLATES).
H. STRUCTURAL STEEL SUPPLIER TO FURNISH LINTELS FOR ALL MASONRY OPENINGS PER
LOOSE LINTEL SCHEDULE OR AS SHOWN OTHERWISE ON STRUCTURAL DRAWINGS. ONE
END OF THE LINTEL SHALL BE FREE TO MOVE HORIZONTALLY TO ALLOW FOR
ELONGATION AND SHORTENING.
I. THE TERMINOLOGY "CONTINUOUS" MEANS QUANTITY. PROVIDE THE NECESSARY JOINT
DETAILS TO ALLOW FOR BUILDING MOVEMENTS. COORDINATE LOCATIONS WITH
ARCHITECTURAL CONTROL AND EXPANSION JOINTS.
J. PROVIDE ANCHOR BOLTS FOR BEAMS BEARING ON MASONRY UNLESS OTHERWISE
NOTED.
E. SLABS, TOPPING, FOOTINGS, BEAMS AND WALLS SHALL NOT HAVE JOINTS IN A
HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK MUST BE MADE AT THIRD POINT OF
SPAN WITH VERTICAL BULKHEADS AND HORIZONTAL SHEAR KEYS UNLESS OTHERWISE
SHOWN. ALL CONSTRUCTION JOINTS SHALL BE AS DETAILED OR AS REVIEWED BY THE
ENGINEER.
EAGLE COUNTY AMENDMENTS.
C
1.5
G. SEISMIC
SOIL SITE CLASS D
DESIGN CATEGORY C
SS 0.348 g
S1 0.008 g
SDS 0.353 g
SD1 0.128 g
BASIC SEISMIC FORCE RESISTING SYSTEM IS WOOD-FRAMED
WALLS SHEATHED WITH WOOD STRUCTURAL PANELS RATED FOR
SHEAR RESISTANCE.
SEISMIC RESPONSE COEFFICIENTS, CS 0.054
RESPONSE MODIFICATION FACTOR, R 6 1/2
ANALYSIS PROCEDURE USED EQUIVALENT LATERAL FORCE
DESIGN BASE SHEAR, V 42.0 KIPS
1
1
4. GLUED-LAMINATED TIMBERS SHALL BE MANUFACTURED AND IDENTIFIED
AS REQUIRED IN ANSI/AITC A190.1 AND ASTM D3737.1
J. SAWN LUMBER SHALL BE INDENTIFIED BY THE GRADE MARK OF LUMBER GRADING OR
INSPECTION AGENCY THAT HAS BEEN APPROVED BY AN ACCREDITATION BODY THAT
COMPLIES WITH DOC PS 20 OR EQUIVALENT.
K. STRUCTURAL CAPACITES AND DESIGN PROVISIONS FOR PREFABRICATED WIID I-JOISTS
SHALL BE ESTABLISHED AND MONITORED IN ACCORDANCE WITH ATSM D5055.
L. WOOD STRUCTURAL PANELS (I.E., COMPOSITE PANELS PLYWOOD, OSB) USED IN A
STRUCTURAL APPLICATION (I.E. SIDING, ROOF AND WALL SHEATHING, SUBFLOORING,
DIAPHRAGMS, AND BUILT-UP MEMBERS) SHALL CONFORM TO THE REQUIREMENTS FOR THEIR
TYPE IN DOC PS 1, DOC PS 2, OR ANSI/APA PRP 210, OR COMPLIANT IDENTIFICATION.
1
1. SOLAR 5 PSF 1
B1
WOOD BEAM
SCHEDULE
MARK BEAM SIZE
B2
B3
B4
B5
B6
B7
(2)-2x10
(2)-9 1/4" LVL
(2)-11 7/8" LVL
(3)-2x8
(3)-2X10
(2)-2x8
(2)-7 1/4" LVL
B8
B9
B10
B11
(3)-9 1/4" LVL
(3)-11 7/8" LVL
(4)-11 7/8" LVL
(3)-7 1/4" LVL
WC1
WOOD COLUMN
SCHEDULE
MARK
(2)-2x4
STUD SIZE
WC2
WC3
WC4
WC5
WC6
WC7
(3)-2x4
(2)-2x6
(3)-2x6
(2)-3 1/2" LVL
(3)-3 1/2" LVL
(4)-3 1/2" LVL
H1
WOOD HEADER SCHEDULE
MARK
(2)-2x8
SIZE TRIMMER STUDS
H2
H3
H4
H5
H6
H7
H8
H9
(3)-2x8
(3)-2x8
(3)-2x8
(3)-2x10
(3)-2x10
(3)-2x10
(3)-7 1/4" LVL
(3)-9 1/4" LVL
(2)-2x4
(2)-2x6
KING STUD
(1)-2x4
(1)-2x6
(2)-2x6
(3)-2x6
(1)-2x6
(2)-2x6
REMARKS
(2)-2x6
(2)-2x6
(2)-2x6
(2)-2x6
(2)-2x6
(2)-2x6
(2)-2x6
(3)-2x6
(2)-2x6
(3)-2x6
NOTES:
1.PROVIDE WOOD COLUMN OF SIZE (3)-2X6 IN 2X6 WALLS AND
(3)-2X4 IN 2X4 WALLS UNLESS OTHERWISE NOTED.
2.PROVIDE 2X6 AT 1'-4"O.C. STUDS IN 2X6 WALL AND 2X4 AT
1'-4" STUDS IN 2X4 THINK WALLS UNLESS OTHERWISE NOTED.
PROJ. NO.
DRAWN:
CHECKED:
DATE:
REVISIONS
SCALE:
SHEET TITLE:
ISSUED
FOR:
APPROVED:
3560 WALNUT ST. UNIT A
DENVER, CO 80205
PHONE 303.758.3800
© NEO STUDIO
2/22/2023 5:08:48 PM12" = 1'-0"HAYMEADOWBUILDING D91 MT. HOPE CIRCLEEAGLE, COLORADO21008177.00
CLH
JIN
11/17/22
PERMIT
GENERAL NOTES
S1.01
JIN
1 02/22/2023 BLDG. DEPT.
RESPONSE AND
REVISIONSC
TYPICAL CONTROL
JOINT DETAIL
X 3/16" WIDE SAW CUT
1/4 OF SLAB DEPTH
5/8"Ø X 2'-0" ROD
CONTINUOUS KEY
1 1 /2" X 1 1/2"
AT 1'-6" GREASED
W.W.R. OR BAR
TYPICAL CONSTRUCTION
JOINT DETAIL
REINFORCING
RE: PLAN
W.W.R. OR BAR
REINFORCING
RE: PLAN
RE: SOILS REPORT
FOR GRAVEL
REQUIREMENTS
RIGID INSULATION
PER PLAN LOCATED
PER ARCHITECTURAL
RIGID INSULATION
PER PLAN LOCATED
PER ARCHITECTURAL SEE PLANSEE PLANTYPICAL STEPPED FOOTING DETAIL
1
1
PROVIDE STANDARD
HOOK IF TENSION Ld.
IS NOT DEVELOPED
STANDARD HOOK
TYPICAL FOOTING
REINFORCEMENT
BARS TO MATCH
TYPICAL FOOTING
REINFORCEMENT 3"3"SEE PLANSEE PLANSEE PLAN
SEE PLAN
TENSION LAP
STANDARD
CORNER REINFORCEMENT DETAIL
TYPICAL 90° HOOK
#5 VERTICAL (TYPICAL)
OR MATCH VERTICAL
WALL REINFORCING
CORNER INTERSECTION
#5 VERTICAL
(TYPICAL)
CORNER INTERSECTION
HORIZONTAL
REINFORCEMENT
(TYPICAL)LAP LENGTHDEVELOPMENTLAP LENGTHDEVELOPMENTLAP LENGTH
DEVELOPMENT
LAP LENGTH
DEVELOPMENT
#5 VERTICAL
(TYPICAL)
#5 VERTICAL
(TYPICAL)LAP LENGTHDEVELOPMENTLAP LENGTH
DEVELOPMENT
LAP LENGTH
DEVELOPMENT
LAP LENGTHDEVELOPMENTTYPICAL NON-LOAD BEARING
PARTITION WALL SUPPORT
40d NAIL AT 2'-0"
DRILL HOLE FOR
SLIP FIT THROUGH
TOP PLATE
SLAB (SEE PLAN)
T.O. CONC.
2X TREATED PLATE
ATTACH TO SLAB WITH
ANCHOR BOLTS OR
RED-HEAD. RIP PLATE
TO MATCH WIDTH OF
STUDS AND BOTH LAYERS
OF GYPSUM BOARD.
(NOTE: COUNTER SINK ALL
EXPANSION BOLTS FOR
1 1/2" CLEARANCE).
NOTE: DO NOT ATTACH BASE
BOARDS TO TOP PLATE.
ATTACH TO BOTTOM PLATE ONLY.SOILS REPORT1 1/2" CLEAR SEE2X6 TREATED PLATE
SLAB ON GRADE
VIEW A-A
AA
HOLDOWN RE:
SCHEDULE
STUD PACK
RE: SCHEDULE
RE: SCHEDULE FOR
ANCHOR ROD SIZE
(NELSON CPL) WELDED
TO EMBED PLATE
(2)-3/4"Ø X H.A.S. FOR DTTZ7
(3)-3/4"Ø X H.A.S. FOR HDU8
(5)-3/4"Ø X H.A.S. FOR HDU14
1/2" EMBED PLATE
(HOLDDOWN-EMBED PLATE)
2X6 TREATED PLATE
SLAB ON GRADE
AA
HOLDOWN RE:
SCHEDULESTUD PACK
RE: SCHEDULE
5/8" Ø ROD AT DTTZZ AND HDU5
(1554 GR 36) DRILLED AND
EPOXY WITH SIMPSON SET XP
(HOLDDOWN-DRILL AND EPOXY)
AND HDU5
NOTE: REBAR NOT
SHOWN FOR CLARITY
NOTE: REBAR NOT
SHOWN FOR CLARITY
2"4"4"4"4"2"1 1/2"1 1/2"2"4"4"2"2"4"2"1 1/2"1 1/2"1 1/2"1 1/2"RE: ARCH
12
ROOF SHEATHING
SEE PLAN
EDGE NAILING
2x BLOCKING
ROOF JOIST
SEE PLAN
SIMPSON H3
AT EACH JOIST
ROOF SHEATHING
SEE PLAN
TRUSS BLOCKING AT 4'-0"
EDGE NAILING
SIMPSON A35 OR LTP4
AT 1'-6" MAXIMUM
2X6 BEARING
WALL AT 1'-4"
SHEARWALL SEE PLAN
AND SCHEDULE
RE: PLAN FOR
HEADER
ROOF SHEATHING
SEE PLAN
ROOF JOIST
SEE PLAN
HEADER
SEE PLAN
EDGE NAILING
.
PROJ. NO.
DRAWN:
CHECKED:
DATE:
REVISIONS
SCALE:
SHEET TITLE:
ISSUED
FOR:
APPROVED:
3560 WALNUT ST. UNIT A
DENVER, CO 80205
PHONE 303.758.3800
© NEO STUDIO
2/22/2023 5:08:48 PM3/4" = 1'-0"HAYMEADOWBUILDING D91 MT. HOPE CIRCLEEAGLE, COLORADO21008177.00
CLH
JIN
11/17/22
PERMIT
CONCRETE DETAILS
S1.02
JIN
3/4" = 1'-0"
SECTION1 3/4" = 1'-0"
SECTION33/4" = 1'-0"
SECTION2 3/4" = 1'-0"
SECTION4
3/4" = 1'-0"
SECTION5
1 02/22/2023 BLDG. DEPT.
RESPONSE AND
REVISIONSC3/4" = 1'-0"
SECTION6 3/4" = 1'-0"
SECTION7 3/4" = 1'-0"
SECTION8
3/4" = 1'-0"
SECTION11
1 1 1
3/4" = 1'-0"
SECTION9 3/4" = 1'-0"
SECTION10
1 1
AND LOWER PLATE SPLICE
2'-4" MINIMUM OFFSET BETWEEN
LOCATIONS OF UPPER PLATE SPLICE
SPLICE AT
UPPER TOP
PLATE
UPPER AND LOWER
PLATES AT TOP
OF WALL
SPLICE AT LOWER
TOP PLATE
(2) ROWS 16d COMMON
NAILS AT 5" (TOTAL 10
NAILS -MINIMUM)
WOOD
STUDSTYPICAL TOP PLATE SPLICE DETAIL
FACE GRAINFACE GRAINTYP. PLATE
SPLICE
1
S03.01
NAILING STAGGERED
AT ADJACENT
PANEL EDGES
PLWOOD
STUDS/BLOCKING AT ADJACENT PANEL
EDGES NAILING SHALL
BE STAGGERED
HOLDOWN AT
SHEARWALL ABOVE
2x (OR) 3x STUDS AS
REQUIRED PR SHEAR
WALL SCHEDULE
THIS SHEET
SILL PLATE
HOLDOWN -AT ENDS OF
SHEARWALL, SEE PLANS
AND DETAILS FOR LOCATIONS
AND OTHER INFORMATION
AT ADJACENT PANEL
EDGES NAILING SHALL
BE STAGGERED
EDGE FASTENING SEE
SHEARWALL SCHEDULE
EDGE MEMBERS FOR
ALL SHEARWALLS
SILL BOLTS OR SILL CONN. WITH 3"X3"X1/4"
PLATE WASHER AT BASE OF SHEARWALL
AT FOUNDATION. SEE SHEARWALL SCHEDULE
TYPICAL PLYWOOD SHEARWALL DETAIL
FIELD, INTERMEDIATE
SUPPORT FASTENERS
FULL HEIGHT STUDS -TYP.
BLOCKING ALL PANEL EDGES
FACE GRAIN
SHEATHING
1/8" GAP
EDGE
FASTENERS
ROOF OR FLOOR
TRUSS TOP CHORD
FLOOR SHEATING SHALL BE GLUED
AND FASTENED PER GENERAL NOTES
AND PLAN NOTES
PANEL BOUNDARY FASTENERS
GENERAL NOTES AND PLAN NOTES
STAGGER SHEATHING
EDGES
SHEATHING EDGE FASTENING
SEE GENERAL NOTES AND
PLAN NOTES
SHEATHING INTERMEDIATE
SUPPORT FASTENING TO
TRUSSES SEE GENERAL
NOTES AND PLAN NOTES
TYPICAL DIAPHRAGM SHEATHING
AT FLOOR AND ROOF
STUDS AT ALL
PANLE POINTS
PLYWOOD SHEATHING
SEE SHEARWALL SCHEDULE
VERTICAL PANEL JOINTS
SHALL BE OFFSET (IN PLAN)
EDGE NAILING
SEE SHEARWALL
SCHEDULE
EDGE NAILING
SEE SHEARWALL
SCHEDULE
SHEARWALL AT PLYWOOD SHEATHING
ON BOTH SIDES
STUDS AT ALL PANEL JOINTS
EDGE NAILING
SEE SHEARWALL
SCHEDULE
VERTICAL PANEL
JOINT LOCATION
PLYWOOD SHEATHING
SEE SHEARWALL SCHEDULE
SHEARWALL AT PLYWOOD
SHEATHING ON ONE SIDE
DOUBLE
TOP PLATE
CRIPPLE
WALL
DO NOT SPLICE
BOTH PLATES AT
BOTTOM
PLATE, RE: SECTIONS
ANCHOR BOLTS WITH 3"X3"X1/4"
PLATE WASHER, RE: PLAN AND
KING STUD CONTINUOUS
SAME LOCATION
PLANS FOR SIZE
HEADER -SEE FRAMING
WINDO
W OR DOOR (1 )-T R IM M E R S T U D C O N T IN U O U S
STUDS
CRIPPLE
TYPICAL HEADER /WALL FRAMING
SHEAR
WALL SCHEDULE
PACK SUPPORTS FRAMING ABOVE
TRIM
MER W
HERE JAMB STUD
BLOCK SOLID TO MATCH
(2)-PIECE BETWEEN WALL
PLATES TYP., U.N.O.
B E T W E E N H E A D E R A N D
B O T T O M W A L L P L A T E
PROVIDE OPENING REINFORCEMENT PER
THIS
SECTION AT SHEARWALLS 4'-0" LONG OR
LESS
TYPICAL SHEARWALL OPENING AT 4'-0" OR SHORTER WALLS
CS16 STRAP
12" X 12" MAXIMUM
OPENING
DOUBLE TOP PLATE
2X BLOCKING
(4)-A35 CLIPS
(2)-TOP & (2)-BOTTOM
(INCHES)
(3000 PSI NORMAL WEIGHT CONCRETE)
OTHER
REINFORCING LAP SCHEDULE
NOTE: Fy = 60,000 psi
3
TOP HOR.
16
OTHER
28
TOP HOR.
821
USE CLASS B SPLICE
LAP SPLICE NOTES:
1.ALL SPLICES SHALL BE WIRED IN CONTACT, STACKED VERTICAL.
2.ALL SPLICES ARE "ls" UNLESS NOTED OTHERWISE.
3.LAP LENGTHS SPECIFICALLY DETAILED ON DRAWINGS SHALL
GOVERN IN LIEU OF LAP LENGTHS SCHEDULE.
4.BUNDLED BAR SPLICES:
A. INDIVIDUAL BAR SPLICES WITHIN THE BUNDLE SHALL
B. INCREASE LAP LENGTH 20% FOR A 3 BAR BUNDLE.
C. INCREASE LAP LENGTH 33% FOR A 4 BAR BUNDLE.
ADJUSTMENTS TO GIVEN LAP LENGTHS:
1.IF REINFORCING IS SPECIFIED AS EPOXY COATED,
2.IN LIGHTWEIGHT AGGREGATE IS SPECIFIED,
3.SCHEDULED LAP LENGTHS ASSUME:
A. CLEAR COVER IS GREATER THAN BAR DIAMETER
B. CLEAR SPACING BETWEEN BARS IS GREATER
C. IF EITHER CONDITION A OR B IS NOT NET,
15
INCREASE SCHEDULED LAG LENGTHS BY 50%.
INCREASE SCHEDULED LAP LENGTHS BY 33%.
AND NOT LESS THAN 3/4"
THAN 2 BAR DIAMETERS.
INCREASE LENGTHS BY 50%.
BE STAGGERED.
SHEARWALL SCHEDULE
2X
2X
MARK
HOLDOWN SCHEDULE
SIMPSON HOLDOWN
NOTES
ANCHOR BOLTS BOUNDARY COLUMN
D HDU14-SDS2.5
NOTES:
1.ALL PLYWOOD AND GYPBOARD PANEL EDGES SHALL BE BLOCKED. BLOCKING SHALL MATCH THE STUDS AT ADJOINING PANEL EDGES.
NAIL SPACING AT 12" ON CENTER ALONG INTERMEDIATE FRAMING MEMBERS.
3.STAGGER ALL SHEATHING JOINT AND SILL PLATE NAILING.
4.NAILS SHALL BE COMMON OR GALVANIZED BOX IN PLYWOOD SHEARWALLS.
ALL PLYWOOD PANELS SHALL BE APA RATED EXPOSURE 1 SHEATHING, UNLESS NOTED OTHERWISE.
6.
INDICATES
SHEARWALL
INDICATES HOLD-DOWN
RE: HOLDOWN SCHEDULE
2.
5.
EXTENT OF SHEARWALL INDICATED BY ON PLAN.
TYPE
TYPE AT EACH END OF WALL
COMMENTS
S1
S2
S3
S4
1.
SIMPSON FLOOR TO FLOOR HOLD-DOWN STRAPS SHALL BE AS NOTED ON PLANS. HOLD-DOWNS ARE CALLED OUT AT
3.MINIMUM HOLD-DOWN COLUMN AT EACH WALL END SHALL BE (2)-2X6 FASTENED TOGETHER WITH NAILING EQUIVALENT
TO THE PANEL EDGE NAILING.
SIMPSON HOLD-DOWNS SHALL BE AS NOTED ON PLAN AND INSTALLED PER MANUFACTURER.
2.
THE TOP OF THE SHEARWALL ON PLAN, AND SHALL BE INSTALLED AT EACH END OF THE WALL.
4.POST INSTALLED ANCHOR BOLTS SHALL BE APPROVED BY ENGINEER OF RECORD PRIOR TO INSTALLATION.
5.ANCHOR BOLTS SHALL BE INSTALLED WITH A HEAVY HEX NUT.
ALL EXTERIOR WALLS SHALL BE TYPE SHEARWALLS UNLESS NOTED OTHERWISE.7.
STEEL PLATE WASHERS 3"X3"X1/4" REQUIRED AT ALL ANCHOR BOLTS.8.
PLAN
MARK
WALL SHEATHING
AND ATTACHMENT
1 1/2" ZIPS PANEL WITH 8d
COMMONS 4" O.C. EDGES,
12" O.C. FIELD
1 1/2" ZIPS PANEL WITH 8d
COMMONS 3" O.C. EDGES,
12" O.C. FIELD
7/16" ZIPS PANEL WITH 8d
COMMONS 4" O.C. EDGES,
12" O.C. FIELD
5/8" GYPSUM WITH 6d
COOLER NAILS AT 4"
ON BOTH SIDES
2X
2X
FRAMING
MEMBERS
AT ABUTTING
PANEL EDGES
SILL PLATE CONNECTION TO
BLOCKING / RIM AT FRAMED FLOORS
(USE SHEARWALL MARK BELOW FLOOR)
16d COMMON NAILS AT 5" O.C. INTO SOLID
BLOCKING OF SDS 1/4" X 4 1/2" WOOD SCREWS
AT 9" OR SIMPSON A35 AT 1'-6" MAX.
16d COMMON NAILS AT 4" O.C. INTO SOLID
BLOCKING OF SDS 1/4" X 4 1/2" WOOD SCREWS
AT 8" OR SIMPSON A35 AT 1'-4" MAX.
16d COMMON NAILS AT 5" O.C. INTO SOLID
BLOCKING OF SDS 1/4" X 4 1/2" WOOD SCREWS
AT 9" OR SIMPSON A35 AT 6" MAX.
16d COMMON NAILS AT 5" O.C. INTO SOLID
BLOCKING OF SDS 1/4" X 4 1/2" WOOD SCREWS
AT 9" OR SIMPSON A35 AT 1'-6" MAX.
ANCHOR BOLTS AT
FOUNDATION OR
STRUCTURAL SLAB
5/8"Ø X 10" ANCHOR BOLT
OR 5/8"Ø X 6 1/2" TITEN HD
AT 2'-8" O.C.
5/8"Ø X 10" ANCHOR BOLT
OR 5/8"Ø X 6 1/2" TITEN HD
AT 2'-8" O.C.
5/8"Ø X 10" ANCHOR BOLT
OR 5/8"Ø X 6 1/2" TITEN HD
AT 2'-8" O.C.
5/8"Ø X 10" ANCHOR BOLT
AT 2'-8" O.C.
BLOCKING / RIM
ATTACHMENT TO
WALL PLATES
SIMPSON A35 OR
LTP4 AT 1'-6" MAX.
SIMPSON A35 OR
LTP4 AT 1'-4" MAX.
SIMPSON A35 OR
LTP4 AT 1'-6" MAX.
SIMPSON A35 OR
LTP4 AT 1'-6" MAX.
C HDU8-SDS2.5
B HDU5-SDS2.5
A DTT2Z
5/8"Ø ANCHOR ROD
RE: X / SXXX AT FOUNDATION AND
FLOOR TO FLOOR SEE ? / SXXX
5/8"Ø ANCHOR ROD
RE: X / SXXX AT FOUNDATION AND
FLOOR TO FLOOR SEE ? / SXXX
7/8"Ø ANCHOR ROD
RE: X / SXXX AT FOUNDATION AND
FLOOR TO FLOOR SEE ? / SXXX
1"Ø ANCHOR ROD
RE: X / SXXX AT FOUNDATION AND
FLOOR TO FLOOR SEE ? / SXXX
(2)-2X6,
(2)-2X4
(2)-2X6,
(3)-2X4
(3)-2X6,
(5)-2X4
(4)-2X6,
(6)-2X4
21
BAR
SIZE
DEVELOPMENT
LENGTH, ld
CLASS B
LAP SPLICE
LENGTH, ls
HOOK
DEVELOPMENT
LENGTH, ldh
COMPRESSION
SPLICE, lc
4 22 37 1128 2028
5 27 46 1436 2536
6 33 56 1643 3043
7 48 81 1962 3562
8 55 93 2271 4071
9 62 104 2580 4580
10 70 118 2890 5090
S1
S#X
NO SCALE
COLUMN CONNECTION
TYPICAL STUD PACK
6 PLY COLUMN
5 PLY COLUMN
4 PLY COLUMN
3 PLY COLUMN
2 PLY COLUMN
CS16 STRAP AT
3RD POINTS AND
(1)-10d AT 1'-0" EACH
PLAY (STAGGERED)
CS16 STRAP AT
3RD POINTS AND
(1)-10d AT 1'-0" EACH
PLAY (STAGGERED)
(1)-10d AT 1'-0" EACH
PLAY (STAGGERED)
(1)-10d AT 1'-0" EACH
PLAY (STAGGERED)
(1)-10d AT 1'-0" EACH
PLAY (STAGGERED)
PROJ. NO.
DRAWN:
CHECKED:
DATE:
REVISIONS
SCALE:
SHEET TITLE:
ISSUED
FOR:
APPROVED:
3560 WALNUT ST. UNIT A
DENVER, CO 80205
PHONE 303.758.3800
© NEO STUDIO
2/22/2023 5:08:49 PM3/4" = 1'-0"HAYMEADOWBUILDING D91 MT. HOPE CIRCLEEAGLE, COLORADO21008177.00
CLH
JIN
11/17/22
PERMIT
TYPICAL FRAMING
SECTIONS
S1.03
JIN
3/4" = 1'-0"
DETAIL1
3/4" = 1'-0"
SECTION6
3/4" = 1'-0"
SECTION5
3/4" = 1'-0"
SECTION3 3/4" = 1'-0"
SECTION4
3/4" = 1'-0"
SECTION7
3/4" = 1'-0"
SECTION2
1 02/22/2023 BLDG. DEPT.
RESPONSE AND
REVISIONSC
#4 AT 2'-0" X 1'-6"1'-6"
#5 AT 1'-4"
(2)-#5 X CONTINUOUS
RE: CIVIL
PATIO
(2)-#5 AT TOP
SEE PLAN4'-0" MIN.1'-0"3" CLR.2X6 TREATED PLATE WITH
5/8"ANCHOR BOLTS
RE: SCHEDULE FOR SPACING
#5 AT 1'-4" EACH WAY
(2) #5 X CONTINUOUS
(2) #5 CONTINUOUS
1 1/2" ZIPS PANEL
RE: ARCH
AT TOP
SLAB ON GRADE
RE: PLAN
2X6 BEARING
WALL AT 1'-4"
1/2" ISOLATION JOINT
6"4'-0" MIN.1'-0"3"SEE PLAN
5 1/2"
2 1/2"8" MIN.RE: SOILS REPORT
FOR 1'-6" DEEP
OVER EXCAVATION
BELOW ALL FOOTINGS
SHEARWALL
RE: PLAN AND
SCHEDULE
#5 AT 1'-4"
(2)-#5 X
CONTINUOUS
(2) #5 CONTINUOUS
AT TOP
2X6 BEARING WALL AT 1'-4"
#5 CONTINUOUS
(SEE PLAN)
T.O. SLAB
8" TYP.MIN.1'-0"1'-0"3" CLR.SEE PLAN
5 1/2"2 1/2"
2X6 TREATED PLATE WITH
5/8"Ø ANCHOR BOLT,
RE: SCHEDULE FOR SPACING
SLAB ON GRADE
RE: PLAN
RE: SOILS
REPORT
FOR GRAVEL
BELOW SLABSEE PLANVARIESSHEARWALL, RE: PLAN
AND SCHEDULE
SLAB ON GRADE
#5 AT 1'-4"
(2)-#5 X CONTINUOUS
(2) #5 CONTINUOUS
AT TOP
RE: PLAN
2X6 TREATED PLATE WITH
5/8"Ø ANCHOR BOLT,
RE: SCHEDULE FOR SPACING
2X6 BEARING WALL AT 1'-4"
#5 CONTINUOUS
SLAB ON GRADE
RE: PLAN
(SEE PLAN)
T.O. SLAB
MIN.1'-0"1'-0"SEE PLAN 8" TYP.3" CLR.5 1/2"2 1/2"
SLAB ON GRADE
#5 AT 1'-4"
(2)-#5 X CONTINUOUS
(2) #5 CONTINUOUS
AT TOP
RE: PLAN
2X4 TREATED PLATE WITH
5/8"Ø ANCHOR BOLT,
AT 2'-8" MAXIMUM(2)-2X4 BEARING WALL AT 1'-4"
#5 CONTINUOUS
ISOLATION JOINT
(SEE PLAN)
T.O. SLAB
3 1/2"2 1/2"1'-0"3" CLR.SEE PLAN
2X6 TREATED PLATE WITH
5/8"∅ANCHOR BOLT,
RE: SHEARWALL SCHEDULE
RE: 2/S-003
(2) #5 X CONTINUOUS
1 1/2" ZIPS PANEL, RE: SHEARWALL
SCHEDULE FOR EDGE NAILING
SLAB ON GRADE
RE: PLAN
2X6 BEARING
WALL AT 1'-4"
1/2" ISOLATION JOINT
FOR SPACING
SIMPSON LUS HANGER
EACH END
2X DECKING
2X8 LEDGER WITH
5/8"Ø X 6" TITEN HD
ANCHORS AT
1'-0" STAGGERED
SIMPSON
AC POST CAP
WOOD POST WITH
ABU POST BASE
WOOD BEAM, RE: PLAN
(3)-#4 TIES AT
TOP AND AT 12"
(7)-#5 VERTICAL MIN.8"1'-0"3" CLR.SEE PLAN4'-0" MIN.4'-0"6"1'-4" Ø
3"
10"
(3)-#5 EACH WAY
ABU POST BASE
6X6 POST WITH
(4)-#4 X REQ.8"
(3)-#3 TIES AT TOP
AND AT 1'-0"1'-0"3" CLR.SEE PLAN4'-0" MIN.6"RE: SOILS REPORT
FOR 1'-6" DEEP
OVER EXCAVATION
BELOW ALL FOOTINGS
EXTERIOR
SLAB-ON-GRADE
L 3X3X1/4 X 0'-6" WITH
(1)-3/4"Ø X 6" TITEN HD
HSS STRINGER
RE: PLAN
JOIST
RE: PLAN
(2)-#4 CONTINUOUSMIN.10"1'-6"
RE: SOILS
REPORT
FOR GRAVEL
BELOW SLAB
3"
COLUMN
DIM
+1 3/4"1 1/2"COLUMNDIM+ 1 3/4"3"1 1/2"1 1/2"3"COLUMNDIM+ 3"3"1 1/2"3"1 1/2"3"3"COLUMNDIM+ 1 3/4"COLUMNDIM+ 1/2"COLUMN
DIM
+ 1/2"
COLUMN
DIM
+ 1/2"
PROVIDE (2)-ADDITIONAL
VERTICAL BAR AT
STEEL COLUMN
(4)-3/4"Ø EXPANSION
PLATE
3/4" X
BASE
CORNER
TYPICAL
BOLTS OR ANCHOR BOLTS
END
SLAB ON GRADE
RE: PLAN
1" SHIM
AND GROUT
STEEL COLUMN
RE: PLAN
8" MIN.BASE
PLATE
3/4"X
BASE
PLATE
3/4"X
2X6 INTERIOR BEARING
WALL WITH SHEATHING
SLAB ON GRADE
#5 AT 1'-4"
(3)-#5 X CONTINUOUS
AT GARAGE
PLUMBING PIPE
IN GROUND
SLOPE
1/2" ISOLATION JOINT
AT INTERIOR
SLAB ON GRADE
CURB ABOVE FOOTING
PROVIDE BLOCKOUT IN
AS REQUIRED AT PLUMBING
PIPES PER M.E.P. PLANS
SLAB AND TURN ABOVE
PIPE TO EXTEND BELOW
FOOTING TO PIPE IN GROUND
TYPICAL PLUMBING THROUGH FOUNDATION WALL1'-0"MIN.1'-0"3" CLR.SEE PLAN
RE: SOILS
REPORT
FOR GRAVEL
BELOW SLAB
#4 AT 2'-0" X 1'-6"1'-6"
#5 AT 1'-4"
(2)-#5 X CONTINUOUS
RE: CIVIL
PATIO OR DECK,
(2)-#5 AT TOP
SEE PLAN4'-0" MIN.1'-0"3" CLR.6"
NOTCH SLAB 1 1/4" X 6"
FOR DOOR SILL
RE: MANUFACTURER
RE: SOILS REPORT
FOR 1'-6" DEEP
OVER EXCAVATION
BELOW ALL FOOTINGS
(6)-#4X CONT.
#4 X
1'-0"
2'-8"
L3X3X3/16 X CONT.
WITH 1/2" Ø HIHI TZ
BOLTS AT 1'-4"
RE: ARCH
FOR FAUX
STONE
(2) #4X CONT. TOP
8"
AT 1'-0"
SHEARWALL
RE: PLAN AND
SCHEDULE
#5 AT 1'-4"
(2)-#5 X
CONTINUOUS
(2) #5 CONTINUOUS
AT TOP
2X4 BEARING WALL AT 1'-4"
#5 CONTINUOUS
(SEE PLAN)
T.O. SLAB
8" TYP.MIN.1'-0"1'-0"3" CLR.SEE PLAN
5 1/2"2 1/2"
2X4 TREATED PLATE WITH
5/8"Ø ANCHOR BOLT,
RE: SCHEDULE FOR SPACING
SLAB ON GRADE
RE: PLAN
RE: SOILS
REPORT
FOR GRAVEL
BELOW SLABSEE PLANVARIESPROJ. NO.
DRAWN:
CHECKED:
DATE:
REVISIONS
SCALE:
SHEET TITLE:
ISSUED
FOR:
APPROVED:
3560 WALNUT ST. UNIT A
DENVER, CO 80205
PHONE 303.758.3800
© NEO STUDIO
2/22/2023 5:08:50 PM3/4" = 1'-0"HAYMEADOWBUILDING D91 MT. HOPE CIRCLEEAGLE, COLORADO21008177.00
CLH
JIN
11/17/22
PERMIT
FOUNDATION SECTIONS
S1.04
JIN
3/4" = 1'-0"
DETAIL1 3/4" = 1'-0"
DETAIL2 3/4" = 1'-0"
DETAIL3 3/4" = 1'-0"
DETAIL4
3/4" = 1'-0"
DETAIL5
3/4" = 1'-0"
DETAIL113/4" = 1'-0"
DETAIL10
3/4" = 1'-0"
DETAIL8
3/4" = 1'-0"
DETAIL9
3/4" = 1'-0"
DETAIL7
3/4" = 1'-0"
SECTION6
3/4" = 1'-0"
DETAIL12 1 02/22/2023 BLDG. DEPT.
RESPONSE AND
REVISIONS
3/4" = 1'-0"
DETAIL13 C
S1A
S1A
S1AS1A S1AS1A
S2B
S1AS1AS1AS1A S1AS2B
S1AS1A S1A
S1AS1A21 3 4 5 6
F
E
D
C
B
A
2'-0"3'-0"TOP OF 4" THICK
100'-0"
SOG
1
S1.04
8
S1.04
4
S1.04
5
S1.04
2
S1.04
10
S1.04
4
S1.04
5
S1.04
2
S1.04
13
S1.04
2'-0"2'-0"2'-0"4
S1.04 3'-0"11'-10 1/2"8'-0"11'-10 1/4"(98'-0")(98'-0")(96'-0")(98'-0")(98'-0")(98'-0")(98'-0")EL (100'-9")
T.O. SLAB
EL (100'-6")
T.O. SLAB
EL (100'-3")
T.O. SLAB
EL (99'-11")
T.O. SLAB
[101'-0"](96'-0")[101'-0"][101'-0"][100'-6"][101'-0"][101'-0"][101'-0"][101'-6"]EL (100'-2")
T.O. SLABEL (100'-5")
T.O. SLAB
EL (99'-8 1/2")
T.O. SLAB
EL (99'-6 1/2")
T.O. SLAB
EL (99'-4")
T.O. SLAB
EL (99'-4 1/2")
T.O. SLAB
EL (99'-2 1/2")
T.O. SLAB
EL (99'-1")
T.O. SLAB
4
S1.04
5
S1.04
(96'-0")
(97'-0")
(96'-0")
(99'-0")(96'-0")(99'-0")
(99'-0")
FOOTING
STEP
(99'-0")
(99'-0")
(97'-0")8"8"FOOTING
STEP
[100'-6"][100'-6"](96'-0")[100'-6"][100'-6"](96'-0")[100'-6"](96'-0")(96'-0")
AT PERIMETER
3'-0" TYP.
8"
EL (100'-0")
T.O. SLAB
3'-0"3'-0"(99'-0")(99'-0") (99'-0")
(99'-0")
(98'-0")(98'-0")
78'-10"
17'-8 1/2"17'-8 1/2"8'-0"17'-8 1/2"17'-8 1/2"62'-10 3/4"6'-5"13'-8 3/4"11'-3 1/2"11'-4"20'-1 1/2"1 1/2"20'-1 3/4"19'-1"23'-5"1 1/2"1 1/2"20'-1 1/2"22'-4 1/2"20'-1 3/4"1 1/2"1 1/2"3'-3 1/2"8'-2 1/2"10'-10 1/4"1 1/2"3
S1.04
3
S1.04
13
S1.04
1 1/2"17'-5 1/2"43'-8"17'-5 1/2"1 1/2"
18'-8"3'-5"9'-1"2'-9"2'-9"43'-8"
1 1/2"1 1/2"
12'-6"
FOOTING
STEP
WALL
STEP
WALL
STEP
WALL
STEP
WALL
STEP
WALL
STEP
WALL
STEP
WALL
STEP
WALL
STEP
WALL
STEP
WALL
STEP
WALL
STEP
WALL
STEP
1
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
WALL
STEP
WALL
STEP
( 96' - 0" )
2'-0"
2'-0"
2'-0"
2'-0"3'-6"8"100'-0"
T.O.SLAB
[ 99' - 4" ]
WALL
STEP
FOOTING
STEP
FOOTING
STEP
1. DATUM ELEVATION 100'-0" EQUALS FIRST LEVEL SLAB ON GRADE.
2. [XXX'-XX"] INDICATES TOP OF FOUNDATION WALL ELEVATION.
3. (XXX'-XX") INDICATES TOP OF FOOTING ELEVATION.
4. {XXX'-XX"} INDICATES TOP OF LEDGE ELEVATION.
5. CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS LISTED IN
SOILS REPORT.
6. CONTRACTOR SHALL PLACE (3)-#5 VERTICALLY FULL HEIGHT OF
WALL AT HIGH SIDE OF ALL WALL STEPS HIGHER THAN 4'-0" IN
ADDITION TO WALL REINFORCEMENT SHOWN OTHERWISE.
7. FLOOR ELEVATIONS SHOWN ARE AT TOP OF SLAB OR AT TOP OF
PLYWOOD FLOOR SHEATHING.
8. FOOTING ELEVATIONS SHOWN ARE MAXIMUMS AND MAY NEED TO
BE LOWERED DUE TO SOIL CONDITIONS. VERIFY CHANGES WITH
STRUCTURAL ENGINEER.
9. PLACE SLAB ON GRADE ON 4-INCH LAYER OF CLEAN GRAVEL AS
OUTLINED IN SOILS REPORT.
10. UNLESS OTHERWISE NOTED - ALL SLAB ON GRADES ARE 4" THICK
WITH 6X6 W2.1 X W2.1 WELDED WIRE FABRIC.
11. PROVIDE CONTROL JOINTS OR CONSTRUCTION JOINTS AS SHOWN
ON FOUNDATION PLAN. MAXIMUM SIZE OF EACH AREA SHALL NOT
EXCEED 225 FT2.
12. CONTRACTOR TO COORDINATE ALL DIMENSIONS AND DETAILS
WITH ARCHITECTURAL DRAWINGS.
13. CENTER FOOTINGS UNDER WALLS AND COLUMNS UNLESS
DIMENSIONED OTHERWISE ON FOUNDATION PLAN.
14. REFER TO ARCHITECTURAL DRAWINGS FOR STAIR FRAMING
DETAILS AND LANDING SLAB ELEVATIONS.
15. ALL SITE WALLS NOT SHOWN ON THIS PLAN SHALL BE BUILT PER
ARCHITECTURAL LANDSCAPE PLANS, DETAILS AND ELEVATIONS.
SITE WALLS SHALL NOT BE CONNECTED TO THE BUILDING UNLESS
NOTED OTHERWISE.
FOUNDATION NOTES:
PROJ. NO.
DRAWN:
CHECKED:
DATE:
REVISIONS
SCALE:
SHEET TITLE:
ISSUED
FOR:
APPROVED:
3560 WALNUT ST. UNIT A
DENVER, CO 80205
PHONE 303.758.3800
© NEO STUDIO
2/22/2023 5:08:51 PMAs indicatedHAYMEADOWBUILDING D91 MT. HOPE CIRCLEEAGLE, COLORADO21008177.00
CLH
JIN
11/17/22
PERMIT
FOUNDATION PLAN -
BUILDING C
S2.01C
JIN
1/4" = 1'-0"
FOUNDATION PLAN - BUILDING C1 C1 02/22/2023 BLDG. DEPT.
RESPONSE AND
REVISIONS
S1A
S1A
S1AS1A S1AS1A
S2B
S1AS1AS1AS1A S1AS2B
S1AS1A S1A
S1AS1AS1AS1AS1A21 3 4 5 6
F
E
D
C
B
A
11 7/8" TJI210
@ 1'-4"
TREATED 2X10
@ 1'-4"
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
TREATED 2X10
@ 1'-4"
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
DECK DECKH211 7/8" TJI210
@ 1'-4"
11 7/8" TJI210
@ 1'-4"
11 7/8" TJI210
@ 1'-4"11 7/8" TJI210
@ 1'-4"
11 7/8" TJI210
@ 1'-4"
UP
ONLY UP
ONLY
B
2
B2
B2B2B2B2B2B2B211 7/8" TJI210
@ 1'-4"
B4
B11 B11
W10x19
B11 B11
11 7/8" TJI210
@ 1'-4"
11 7/8" TJI210
@ 1'-4"H3H2H3 H2B10
H2H3H2H3H2B10
B1 B3 B1B3B3
2
S3.01
8
S3.01 8
S3.01
14
S3.01
6
S3.01
15
S3.01
1
S3.01
14
S3.01
2
S3.01
8
S3.01
8
S3.01
18
S3.01
7
S3.01
16
S3.01
10
S3.01
7
S3.01
8
S3.01
1
S3.01
17
S3.01
15
S3.01
DUXXBAK
DECKING
6X6 POST UP
SIM.
11 7/8" TJI210 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
TREATED
2X10 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
TREATED
2X10 @ 1'-4"
UP
ONLY
UP
ONLY UP
ONLY
UPUPUPUP
ONLY
UP
ONLY
UP
ONLY
UP
ONLYUP
ONLY
UP
WC6
UP
WC6
UP
WC6
UP
ONLY
UP
ONLY
B3
(3)-2x10 TREATED(3)-2x10 TREATED
(3)-2x10 TREATED
(3)-2x10 TREATED
(3)-2x10 TREATED(3)-2x10 TREATEDDUXXBAK
DECKING
78'-10"
17'-8 1/2"17'-8 1/2"8'-0"17'-8 1/2"17'-8 1/2"62'-10 3/4"6'-5"13'-8 3/4"11'-3 1/2"11'-4"20'-1 1/2"B2
6X6 POST UP
110'-1 3/4"
TOP OF 1 1/2" THICK
GYPCRETE ON 3/4"
THICK SHEATHING
H7 H8H8W10x45
B3 B11 B3 B3 B3
W10x54< 109' - 10 1/2" >(2)-11 7/8" TJI210
@ 1'-4"
(2)-11 7/8" TJI210
@ 1'-4"
UP UP
UP
UP
UP
UP
UP
UP
UP UP UP UP
UP UPUPUP
UP
UP
H5 B4 H5
UP
ONLY
UP
ONLY
1
H7
B2 B2
UP
1 1
1
1
B2
B7B7 B7
1
1
(2)-2x10 TREATED(2)-2x10 TREATED1
1
1B9W10x26
UPUPUPUPUPB2B11B11
B11B11
W10x19
WC6WC6WC6
B7B7B7
W10x26B9UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
B10WALLABOVE2X10
@ 2'-0"
1
H21. ALL WOOD FRAMING JOISTS SHALL BE BCI 6000 TYPE JOIST AS MANUFACTURED
BY BOISE CORPORATION. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY
AND SHALL BE REVIEWED BY THE ENGINEER OF RECORD.
2. "VL" INDICATES VERSA-LAM BEAMS, AS MANUFACTURED BY BOISE CORPORATION
ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE
STRUCTURAL GENERAL NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED "UP ONLY".
5. < > INDICATES TOP OF BEAM ELEVATION OR PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. HEADERS SHALL BE (3)-2X10 UNLESS NOTED OTHERWISE. ALL HEADERS SHALL BE BUILT
OUT TO 5 1/2" (3 1/2") WIDTH BY ADDING PLYWOOD SPACERS AS REQUIRED.
8. ALL COLUMNS SHALL BE (3)-2X6 OR (3)-2X4 UNLESS NOTED OTHERWISE.
9. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
10. INDICATES INTERIOR BEARING WALLS. FLOOR JOISTS BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
11. ALL BEAM/BEAM AND BEAM/COLUMN CONNECTIONS SHALL BE MADE WITH SIMPSON
STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
12. RE: ARCHITECTURAL DRAWINGS FOR LOCATION AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
13. FOR ADDITIONAL DETAILS, FLOOR DIAPHRAGM NAILING SCHEDULE AND PLYWOOD
SHEAR WALL NAILING SCHEDULE SEE SHEET S-001.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. ALL EXTERIOR WALLS SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR
OR FLOOR TO ROOF (INCLUDING RAKE WALLS).
16. RE: SHEET S-000 FOR GENERAL NOTES.
WOOD FRAMING NOTES:
17. DENOTES MOMENT CONNECTION.
18. INDICATES ADDITIONAL FRAMING FOR HOT TUB LOADING OF 125 psf.
PROJ. NO.
DRAWN:
CHECKED:
DATE:
REVISIONS
SCALE:
SHEET TITLE:
ISSUED
FOR:
APPROVED:
3560 WALNUT ST. UNIT A
DENVER, CO 80205
PHONE 303.758.3800
© NEO STUDIO
2/22/2023 5:08:52 PMAs indicatedHAYMEADOWBUILDING D91 MT. HOPE CIRCLEEAGLE, COLORADO21008177.00
CLH
JIN
11/17/22
PERMIT
LEVEL 2 FRAMING PLAN
-BUILDING C
S2.02C
JIN
1/4" = 1'-0"
LEVEL 2 FRAMING PLAN - BUILDING C1 C1 02/22/2023 BLDG. DEPT.
RESPONSE AND
REVISIONS
S1A
S1A
S1AS1AS1AS1A S1AS1AS1AS2BS1AS1AS1AS1A S1AS2B
S1AS1A S1A
21 3 4 5 6
F
E
D
C
B
A
11 7/8" TJI210 @ 1'-4"
11 7/8" TJI230 @ 1'-4"
11 7/8" TJI230 @ 1'-4"
H3
H2
B1B3B1B3
B1H2H2H3 H2H3H1H1
TREATED 2X10
@ 1'-4"
B4
B4
11 7/8" TJI210
@ 1'-4"
11 7/8" TJI210 @ 1'-4"
11 7/8" TJI230 @ 1'-4"
H3
2X4 @ 1'-0" O.C.2X4 @ 1'-0" O.C.
2X4 @ 1'-0" O.C.2X4 @ 1'-0" O.C.WC6WC6WC6WC6WC6
UP
WC6 UP
ONLY
WC6 WC6
WC6 WC5
WC5
WC6WC5
WC5
3
S3.01
2
S3.01
14
S3.01
8
S3.01
2
S3.01
2
S3.01
10
S3.01
14
S3.01
9
S3.01
1
S3.01
15
S3.01
1
S3.01
14
S3.01
2
S3.01
8
S3.01
8
S3.01
8
S3.01
2
S3.01
1
S3.01
SIM.
B10B10
B10B10 (3)-11 7/8" LVL
(2)-2x10 TREATED(2)-2x10 TREATED(3)-2x10 TREATED
(3)-2x10 TREATED11 7/8" TJI230 @ 1'-4"
11 7/8" TJI230 @ 1'-4"
H3
H2 H2H3
H2H2B1
B3B1B3B1
H1 H1TREATED 2X10
@ 1'-4"
11 7/8" TJI230 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
TREATED
2X10 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
TREATED
2X10 @ 1'-4"H2H2
H2H2B1 B3 B3
B3 B3H3H
1
11 7/8" TJI210 @ 1'-4"
11 7/8" TJI210 @ 1'-4"
TREATED
2X10 @ 1'-4"H2H3 H2H3
H2
B3 B3
B3 B3 B1
H2H3H 111 7/8" TJI210 @ 1'-4"
B2 (3)-2x10 TREATED(3)-2x10 TREATED
(2)-2x10 TREATED(2)-2x10 TREATED
H3
UP
ONLY
78'-10"
17'-8 1/2"17'-8 1/2"8'-0"17'-8 1/2"17'-8 1/2"62'-10 3/4"6'-5"13'-8 3/4"11'-3 1/2"11'-4"20'-1 1/2"120'-3 1/2"
TOP OF 1 1/2" THICK
GYPCRETE ON 3/4"
THICK SHEATHING
(3)-2x10 TREATED(3)-2x10 TREATED(2)-2x10 TREATED(2)-2x10 TREATED(3)-2x10 TREATED(3)-2x10 TREATED15
S3.01
1
S3.01
8
S3.012
S3.01
2
S3.01
1
S3.01
1
S3.01
10
S1.02
1. ALL WOOD FRAMING JOISTS SHALL BE BCI 6000 TYPE JOIST AS MANUFACTURED
BY BOISE CORPORATION. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY
AND SHALL BE REVIEWED BY THE ENGINEER OF RECORD.
2. "VL" INDICATES VERSA-LAM BEAMS, AS MANUFACTURED BY BOISE CORPORATION
ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE
STRUCTURAL GENERAL NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED "UP ONLY".
5. < > INDICATES TOP OF BEAM ELEVATION OR PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. HEADERS SHALL BE (3)-2X10 UNLESS NOTED OTHERWISE. ALL HEADERS SHALL BE BUILT
OUT TO 5 1/2" (3 1/2") WIDTH BY ADDING PLYWOOD SPACERS AS REQUIRED.
8. ALL COLUMNS SHALL BE (3)-2X6 OR (3)-2X4 UNLESS NOTED OTHERWISE.
9. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
10. INDICATES INTERIOR BEARING WALLS. FLOOR JOISTS BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
11. ALL BEAM/BEAM AND BEAM/COLUMN CONNECTIONS SHALL BE MADE WITH SIMPSON
STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
12. RE: ARCHITECTURAL DRAWINGS FOR LOCATION AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
13. FOR ADDITIONAL DETAILS, FLOOR DIAPHRAGM NAILING SCHEDULE AND PLYWOOD
SHEAR WALL NAILING SCHEDULE SEE SHEET S-001.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. ALL EXTERIOR WALLS SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR
OR FLOOR TO ROOF (INCLUDING RAKE WALLS).
16. RE: SHEET S-000 FOR GENERAL NOTES.
WOOD FRAMING NOTES:
17. DENOTES MOMENT CONNECTION.
18. INDICATES ADDITIONAL FRAMING FOR HOT TUB LOADING OF 125 psf.
PROJ. NO.
DRAWN:
CHECKED:
DATE:
REVISIONS
SCALE:
SHEET TITLE:
ISSUED
FOR:
APPROVED:
3560 WALNUT ST. UNIT A
DENVER, CO 80205
PHONE 303.758.3800
© NEO STUDIO
2/22/2023 5:08:53 PMAs indicatedHAYMEADOWBUILDING D91 MT. HOPE CIRCLEEAGLE, COLORADO21008177.00
CLH
JIN
11/17/22
PERMIT
LEVEL 3 FRAMING PLAN
-BUILDING C
S2.03C
JIN
1/4" = 1'-0"
LEVEL 3 FRAMING PLAN - BUILDING C1 C&E1 02/22/2023 BLDG. DEPT.
RESPONSE AND
REVISIONS
S1A
S1A
S1A
S1AS1AS1AS1A S1AS1AS1AS2BS1AS1AS1A S1AS2B
S1AS1A S1A
21 3 4 5 6
F
E
D
C
B
A
B1 B4 B1 B5
B1
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
B4 B4
B4B4B1
B4 B4
B4 B4 B1
H3
H2H6 H2H2H2H1 H1H6H6H2H2H3
H2
H6
H2H 1B4
B4
B11
B1B4B1B5
B1H2H2H3 H2H2 H6
H1H1H6
H6H
1
H2
H3H2H2 H6
H2(FLUSH)
(DROPPED)
WC6
WC6
PREFABRICATED
ROOF TRUSS
AT 2'-0"
11 7/8" 210
TJI AT 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
REFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
11 7/8" LVL
AT 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
AT 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
11 7/8" LVL
AT 2'-0"
WC6
WC5
WC5WC6
WC5
WC5
WC6
RIDGE.RIDGE.RIDGE.
1
S4.01
11 7/8" 210
TJI AT 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"
5/8" THICK
SHEATHING TYP.
5/8" THICK
SHEATHING TYP.
5/8" THICK
SHEATHING TYP.
5/8" THICK
SHEATHING TYP.
78'-10"
17'-8 1/2"17'-8 1/2"8'-0"17'-8 1/2"17'-8 1/2"62'-10 3/4"6'-5"13'-8 3/4"11'-3 1/2"11'-4"20'-1 1/2"H7H7H7B11
1
S4.01
4
S4.01
2
S4.01
7
S4.01
17
S4.01
18
S4.01
19
S4.01
13
S4.01
4
S4.01
14
S4.01
15
S4.01
16
S4.01
9
S4.01
10
S4.01
2
S4.01
14
S4.01
15
S4.01
12
S4.01
14
S4.01
15
S4.01
16
S4.01
9
S4.01
10
S4.01
13
S4.01
14
S4.01
15
S4.01
12
S4.01
4
S4.01
4
S4.01
4
S4.01
7
S4.01
PREFAB WOOD ROOFGIRDER TRUSSPREFAB WOOD ROOFGIRDER TRUSSPREFAB WOOD ROOFGIRDER TRUSSPREFABRICATED
WOOD ROOF TRUSS
AT 2'-0"
PREFABRICATED
WOOD ROOF TRUSS
@ 2'-0"PREFAB WOOD ROOFGIRDER TRUSS<129'-4 1/2"><129'-4 1/2"><128'-4 7/8"><129'-4 1/2"><129'-3 1/4">
<124'-4 1/2"><129'-3 1/4"><129-3 1/4"><129'-3 1/4"><129'-3 1/4"><128'-4 1/2"><128'-4 1/2">
<123'-3 3/4">
<128'-4 1/2"><128'-4 1/2">
<128'-4 1/2">
<128'-4 1/2">
WC6
WC6
WC6 H711
S4.01
3
S4.01
3
S4.01
11
S4.01
(1)-11 7/8" LVLBOLTED TO FACEOF WALLBOLTED TO FACEOF WALL(1)-11 7/8" LVLOVERFRAME OVERFRAME
SIM.
7
S1.02
8
S1.02
6
S1.02
7
S1.02
19
S4.01
18
S4.01
SIM.
18
S4.01
20
S4.01
17
S4.01
20
S4.01
BOLTED TO FACEOF WALL(1)-11 7/8" LVL18
S4.01
7
S1.02
8
S1.02 18
S4.01
18
S4.01
6
S1.02
7
S1.02
18
S4.01 BOLTED TO FACEOF WALL(1)-11 7/8" LVLPREFABRICATED ROOF TRUSS NOTES:
1. PREFABRICATED ROOF TRUSS LOADS:
LIVE LOADS AT TOP CHORD =50 #/FT2
DEAD LOADS AT TOP CHORD =10 #/FT2 + 5 PSF SOLAR
DEAD LOADS AT BOTTOM CHORD =10 #/FT2
WIND LOADS - SEE STRUCTURAL GENERAL NOTES
STRESS INCREASES OR LOAD REDUCTIONS ARE NOT PERMITTED.
(CHECK SPECIAL ATTIC LIVE LOAD REQUIREMENTS).
3. SHOP DRAWINGS SHALL BE SUPPLIED BY MANUFACTURER AND REVIEWED BY
CONTRACTOR, ARCHITECT, AND STRUCTURAL ENGINEER.
4. THE TRUSS SUPPLIER SHALL BE RESPONSIBLE FOR THE FOLLOWING ITEMS:
A.ENGINEERING OF ALL TRUSSES AND CONNECTIONS AND SHOWING OF ALL
ON SHOP DRAWINGS.
B.DESIGN AND SUPPLY OF ALL TRUSS BEARING CONNECTORS AND
C. PLACING OF TRUSSES TO ACCOMMODATE MECHAANICAL EQUIPMENT
WITHOUT CUTTING TRUSSES.
5. SIMPSON H2.5 CLIP ANGLES SHALL BE INSTALLED AT ALL EXTERIOR WALL
TRUSS BEARING LOCATIONS UNLESS NOTED OTHERWISE ON ROOF DETAILS.
6. DETAIL ALL PREFABRICATED TRUSSES TO BE ALIGNED WITH WALL STUDS BELOW.
7. TRUSS SUPPLIER TO CONFIRM ROOF AND CEILING SLOPES AND CONFIGURATION
WITH ARCHITECTURAL DRAWINGS PRIOR TO FABRICATION.
8. RE: SHEET S1.00 FOR GENERAL NOTES.
2. ROOF TRUSS LIVE LOAD DEFLECTION SHALL BE LIMITED TO SPAN/360.
NOT TO EXCEED 1". TOTAL LOAD DEFLECTION SHALL BE LIMITED TO SPAN/240.
HOLD DOWNS.
1
ROOF FRAMING NOTES:
1. ROOF SHEATHING 5/8" (40/20 SPAN RATING). STAGGER PANEL END JOINTS AND
FASTEN WITH 10d NAILS AT 6" MAXIMUM ALL EDGES AND 1'-0" MAXIMUM OTHER
SUPPORTS (SEE ROOF DIAPHRAGM NAILING SCHEDULE SHEET S-001 ).
2. RE: ARCHITECT FOR ROOF SLOPES AND BEARING PLATE HEIGHTS NOT NOTED.
3. ALL HEADERS SHALL BE (3)-2X10 UNLESS OTHERWISE NOTED. ALL HEADERS
SHALL BE BUILT OUT TO 5 1/2" OR 3 1/2" WIDTH BY ADDING PLYWOOD SHIMS
4. ALL HEADERS LONGER THAN 6'-0" SHALL REQUIRE TWO TRIM STUDS AND
TWO KING STUDS EACH SIDE.
5. ALL BEAM TO COLUMN CONNECTIONS, BOTH TOP AND BOTTOM SHALL USE
SIMPSON PLATE CONNECTORS UNLESS NOTED OTHERWISE ON DETAILS.
7. ALL EXTERIOR WALLS SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO
ROOF (INCLUDING RAKE WALLS).
8. < > INDICATES TOP OF ROOF BEAM OR TOP OF PLATE HEIGHT.
10. RE: SHEET S-000 FOR GENERAL NOTES.
11. RE: ARCHITECT FOR CHIMNEY SIZES AND LOCATIONS NOT NOTED ON
12. OVERFRAMING SHALL BE 2X6 MINIMUM AND SHALL BE POSTED DOWN TO
MAIN TRUSSES ON A GRID NOT TO EXCEED 4'-0" X 4'-0" (16 FT2).
13. FOR ADDITIONAL NOTES AND DETAILS SEE SHEET S-001 .
14. RE: ARCHITECTURAL DRAWINGS FOR ALL OVERFLOW SCUPPER LOCATIONS.
16. ALL COLUMNS SHALL BE (3)-2X6 OR (3)-2X4 UNLESS OTHERWISE NOTED.
18. INDICATES INTERIOR BEARING WALLS.
AS REQUIRED.
STRUCTURAL PLANS.
PROJ. NO.
DRAWN:
CHECKED:
DATE:
REVISIONS
SCALE:
SHEET TITLE:
ISSUED
FOR:
APPROVED:
3560 WALNUT ST. UNIT A
DENVER, CO 80205
PHONE 303.758.3800
© NEO STUDIO
2/22/2023 5:08:55 PMAs indicatedHAYMEADOWBUILDING D91 MT. HOPE CIRCLEEAGLE, COLORADO21008177.00
CLH
JIN
11/17/22
PERMIT
ROOF FRAMING PLAN -
BUILDING C
S2.04C
JIN
1/4" = 1'-0"
ROOF FRAMING PLAN - BUILDING C1
1 02/22/2023 BLDG. DEPT.
RESPONSE AND
REVISIONSC
16d NAIL OR SDS SCREW
SEE SHEARWALL SCHEDULE
FOR SPACING
FLOOR SHEATHING
SEE PLAN
FLOOR JOIST
SEE PLAN
FRAMING CLIP
SEE SHEARWALL SCHEDULE
FOR SPACING
1 1/4" VERSA
STRAND BOARD
1 1/2" ZIPS PANEL
1 1/2" GYPCRETE
TOPPING
16d NAIL OR SDS SCREW
SEE SHEARWALL SCHEDULE
FOR SPACING
FLOOR SHEATHING
SEE PLAN
FLOOR JOIST
SEE PLAN
BCI BLOCKING AT 4'-0"
FRAMING CLIP
SEE SHEARWALL SCHEDULE
FOR SPACING
1 1/4" VERSA
STRAND BOARD
1 1/2" ZIPS PANEL
1 1/2" GYPCRETE
TOPPING
1" TYP.1" TYP. 4" 4"
1 1/2" GYPCRETE
TOPPING
BCI BLOCKING
AT 4'-0"
HEADER
SEE PLAN
DOOR
SEE ARCH.
RAILING
SEE ARCH.
SLOPED DECK JOIST
SEE PLAN
SIMPSON LUS28 HANGER
2X8 LEDGER WITH SDWS WOOD
SCREWS AT 8" STAGGERED
(4)-1/4"Ø X 4 1/2" SCS SCREWS
GLU-LAM BEAM
SEE PLAN
1/4 X
1/8
SIMPSON SDWC15600
WOOD SCREW AT 22.5°
(TYPICAL EVERY JOIST)
1 1/4" THICK X 6"
"DUXXBAK" COMPOSTIE
DECKING SEE ARCH.
AND SPECS.
1 1 1/2" GYPCRETE
TOPPING EDGE NAILING
FLOOR SHEATHING
FLOOR JOIST
SEE PLAN
FRAMING CLIP PER
SHEARWALL SCHEDULE
SHEARWALL
SEE PLAN
BCI BLOCKING
AT 4'-0"
END OF
SHEARWALL
ALTERNATE
STRAP TIE
SOLID BLOCKING
SHEARWALL COLUMN
SEE PLAN
DRILL PLATES FOR
THREADED RODPARALLEL CASEFLOOR FRAMINGOMIT ATTHREADED ROD
RE: MANUFACTURER
FOR DIAMETER
HDU4-SDS2.5
HOLDOWN SEE PLAN
2"16d NAIL OR SDS SCREW
SEE SHEARWALL SCHEDULE
FOR SPACING
FLOOR SHEATHING
SEE PLAN
FLOOR JOIST
SEE PLAN
FRAMING CLIP
SEE SHEARWALL SCHEDULE
FOR SPACING
1 1/2" GYPCRETE
TOPPING1 1/2" ZIPS PANEL
SEE PLAN
BEAM
SEE PLAN
1 1/4" VERSA -STRAND
RIM BOARD BLOCKING
FLOOR JOIST
SEE PLAN
2X4 BEARING
WALL AT 1'-4"
FLOOR SHEATHING
SEE PLAN
1 1/2" GYPCRETE
TOPPING
2x BLOCKING
FLOOR JOIST
SEE PLAN
SHEARWALL, SEE PLAN
AND SCHEDULE
FLOOR SHEATHING
SEE PLAN
1 1/2" GYPCRETE
TOPPING
2x BLOCKING
16d OR SDS SCREW PER
SHEARWALL SCHEDULE
SHEARWALL, SEE PLAN
AND SCHEDULE
FRAMING CLIP PER
SHEARWALL SCHEDULE
16d NAIL OR SDS SCREW
SEE SHEARWALL SCHEDULE
FOR SPACING
FLOOR SHEATHING
SEE PLAN
FLOOR JOIST
SEE PLAN
FRAMING CLIP
SEE SHEARWALL SCHEDULE
FOR SPACING
1 1/2" GYPCRETE
TOPPING
SHEARWALL SEE PLAN
AND SCHEDULE
BCI BLOCKING
AT 4'-0"
RIM BOARD
2X4 BEARING WALL
AT 1'-4"3"MIN.3 1/2"(2)-9 1/2" LVL BEAM
FLOOR SHEATHING
JOIST WITH SIMPSON
LUS28 HANGER
(2)-2X4 BEARING
WALL AT 1'-4"~L2 1/2 X 2 1/2 X 1/4 X 0'-7" ANGLE
WITH (2)-1/2"Ø THRU-BOLTS
HSS STRINGER
SEE PLAN
STAIRS,
SEE ARCH.
3/16
3 SIDES
1/8
3/16
HSS BEAM
SEE PLAN
RAILING
SEE PLAN
LANDING
SEE PLAN
HSS STRINGER
SEE PLAN
3/16
HSS BEAM
SEE PLANL1 1/2 X 1 1/2 X 1/4 X CONTINUOUS
HSS BEAM WITH WOOD NAILER
WITH (2)-1/4"TEK SCREWS AT 1'-4"
FLOOR SHEATHING
JOIST WITH SIMPSON
LUS28 HANGER
(2)-2X4 BEARING
WALL AT 1'-4"
3/16
3/16
TYP.
HSS STRINGER
SEE PLAN
3/16
3/16 3/16
1/4" X 3 1/2" X 1'-6" PLATE
L4X4X1/4X0'-4"
STEEL BEAM
SEE PLAN
HSS COLUMN
FLOOR SHEATHING
SEE PLAN
FLOOR JOIST
SEE PLAN
1 1/2" GYPCRETE
TOPPING
BEAM
SEE PLAN
1 1/2" GYPCRETE
TOPPING
BCI BLOCKING
AT 4'-0"
HEADER
SEE PLAN
DOOR
SEE ARCH.
RAILING
SEE ARCH.
TREATED SLOPED
DECK JOIST
SEE PLAN
SIMPSON LUS28 HANGER
TREATED 2X10 LEDGER WITH SDWS WOOD
SCREWS AT 8" STAGGERED
(3) TREATED
2x BEAM
SEE PLAN
1" TYP.1" TYP. 4" 4"
1/4 X
1/8
SIMPSON SDWC15600
WOOD SCREW AT 22.5°
(TYPICAL EVERY JOIST)
1 1/4" THICK X 6"
"DUXXBAK" COMPOSTIE
DECKING SEE ARCH.
AND SPECS.
1 1" TYP.1" TYP. 4" 4"RAILING
SEE ARCH.
1/4 X
1/8
SIMPSON SDWC15600
WOOD SCREW AT 22.5°
(TYPICAL EVERY JOIST)
FLOOR SHEATHING SEE ARCH.
TREATED SLOPED
DECK JOIST
SEE PLAN
SIMPSON LUS28 HANGER
(3) TREATED
2x BEAM
SEE PLAN
16d NAIL OR SDS SCREW
SEE SHEARWALL SCHEDULE
FOR SPACING
FLOOR SHEATHING
SEE PLAN
FLOOR JOIST
SEE PLAN
BCI BLOCKING AT 4'-0"
FRAMING CLIP
SEE SHEARWALL SCHEDULE
FOR SPACING
1 1/4" VERSA
STRAND BOARD
1 1/2" ZIPS PANEL
1 1/2" GYPCRETE
TOPPING
16d NAIL OR SDS SCREW
SEE SHEARWALL SCHEDULE
FOR SPACING
ROOF SHEATHING
SEE PLAN
ROOF JOIST
SEE PLAN
FRAMING CLIP
SEE SHEARWALL SCHEDULE
FOR SPACING
1 1/4" VERSA -STRAND
RIM BOARD BLOCKING
1 1/2" ZIPS PANEL
SEE PLAN
BEAM
SEE PLAN
12
1
PROJ. NO.
DRAWN:
CHECKED:
DATE:
REVISIONS
SCALE:
SHEET TITLE:
ISSUED
FOR:
APPROVED:
3560 WALNUT ST. UNIT A
DENVER, CO 80205
PHONE 303.758.3800
© NEO STUDIO
2/22/2023 5:08:56 PM3/4" = 1'-0"HAYMEADOWBUILDING D91 MT. HOPE CIRCLEEAGLE, COLORADO21008177.00
CLH
JIN
11/17/22
PERMIT
FLOOR FRAMING
SECTIONS
S3.01
JIN
3/4" = 1'-0"
DETAIL1 3/4" = 1'-0"
DETAIL2 3/4" = 1'-0"
DETAIL3 3/4" = 1'-0"
DETAIL4 3/4" = 1'-0"
DETAIL5
3/4" = 1'-0"
DETAIL6 3/4" = 1'-0"
DETAIL7 3/4" = 1'-0"
DETAIL8 3/4" = 1'-0"
DETAIL9 3/4" = 1'-0"
DETAIL10
3/4" = 1'-0"
DETAIL11 3/4" = 1'-0"
DETAIL12 3/4" = 1'-0"
DETAIL13 3/4" = 1'-0"
DETAIL14
3/4" = 1'-0"
DETAIL15 3/4" = 1'-0"
DETAIL16 3/4" = 1'-0"
DETAIL17
1 02/22/2023 BLDG. DEPT.
RESPONSE AND
REVISIONS
3/4" = 1'-0"
DETAIL18 C1
RE: ARCH
12
ROOF SHEATHING
SEE PLAN
ROOF TRUSS
SEE PLAN
1/2" THICK PLYWOOD
SHEATHING
RE: ARCH
12
SIMPSON LS70
(TYPICAL EVERY JOIST)
ROOF SHEATHING
SEE PLAN
PACK WEB
~
SIMPSON
H2.5 CLIP
POST DOWN TO MAIN
TRUSSES ON A GRID
NOT TO EXCEED
2'-8"X2'-8" (7.1FT2)
GIRDER TRUSS
SEE PLAN
DL = 170 PLF
SL -540 PLF
PREFAB ROOF TRUSS
SEE PLAN
ROOF SHEATHING
SEE PLAN
2x BLOCKING
ROOF JOIST
SEE PLAN
LVL BEAM
SEE PLAN
ROOF SHEATHING
SEE PLAN
ROOF TRUSS
SEE PLAN
SIMPSON H2.5 CLIP
HEADER
SEE PLAN
EDGE NAILING
1/2" THICK PLYWOOD
SHEATHING
RE: ARCH
12
ROOF SHEATHING
SEE PLAN
EDGE NAILING
EDGE NAILING
1/2" THICK PLYWOOD
SHEATHING
SIMPSON H2.5 CLIP
ROOF TRUSS
SEE PLAN
DRAG TRUSS, TRUSS
MANUFACTURER TO DESIGN
FOR 350 PLF LATERAL LOAD
RE: ARCH
12
ROOF SHEATHING
SEE PLAN
SIMPSON
H2.5 CLIP PREFAB ROOF TRUSS
SEE PLAN
ROOF SHEATHING
SEE PLAN
TRUSS BLOCKING, LOCATE
OVER SHEARWALL. TRUSS
MAUFACTURER TO DESIGN
FOR 460 PLF
PREFAB ROOF TRUSS
AT 4'-0"
EDGE NAILING
SHEARWALL WHERE
OCCURS ON PLAN
2X6 OR 2X4 BEARING
WALL AT 1'-4"
PROVIDE FRAMING CLIP
PER SHEARWALL SCHEDULE
IF SHEATHING IS NOT
CONTINUOUS TO UNDERSIDE
OF ROOF SHEATHING
RE: ARCH
12
ROOF SHEATHING
SEE PLAN
SIMPSON
H2.5 CLIP
PREFAB ROOF TRUSS
SEE PLAN
RE: ARCH
12
ROOF SHEATHING
SEE PLAN
EDGE NAILING
EDGE NAILING
1 1/2" THICK PLYWOOD
SHEATHING
SIMPSON
H2.5 CLIP
ROOF JOIST
SEE PLAN
ROOF SHEATHING
SEE PLAN
TRUSS BLOCKING AT 4'-0"
EDGE NAILING
DRAG TRUSS, TRUSS
MANUFACTURER TO DESIGN
FOR 350 PLF LATERAL LOAD
SIMPSON A35 OR LTP4
AT 1'-6" MAXIMUM
2X6 BEARING
WALL AT 1'-4"
SHEARWALL SEE PLAN
AND SCHEDULE
RE: PLAN FOR HEADER
ROOF SHEATHING
SEE PLAN
TRUSS BLOCKING AT 4'-0"PREFAB ROOF TRUSS
AT 4'-0"
EDGE NAILING
DRAG TRUSS, TRUSS
MANUFACTURER TO DESIGN
FOR 350 PLF LATERAL LOAD
SIMPSON A35 OR LTP4
AT 1'-6" MAXIMUM
2X6 BEARING
WALL AT 1'-4"
SHEARWALL SEE PLAN
AND SCHEDULE
FLOOR / ROOF TRUSS OR
PROVIDE 2X BOCKING AT 2'-0"
SIMPSON DTC TRUSS CLIP (EACH TRUSS)
ATTACH TO TRUSS WITH (2)-8d NAILS
(DO NOT DRIVE NAIL TIGHT AND INSTALL
IN MIDDLE OF SLOT) AND ATTACH TO
TOP PLATE WITH (4)-8d NAILS
1X FILLER
NON-LOAD BEARING WALL3/4" GAPPROVIDE DRYWALL JOINT
TO ACCOMODATE 3/4" OF
MOVEMENT. SEE ARCH.
RE: ARCH
12
ROOF SHEATHING
SEE PLAN
SIMPSON
H2.5 CLIP
ROOF TRUSS
SEE PLAN
ROOF SHEATHING
SEE PLAN
PREFAB ROOF TRUSS
SEE PLAN
RE: ARCH
12
EDGE NAILING
SIMPSON H2.5 CLIP
ROOF TRUSS
SEE PLAN
RE: PLAN FOR
HEADER
TRUSS BLOCKING
TYP
ROOF SHEATHING
SEE PLAN
TRUSS BLOCKING AT 4'-0"
EDGE NAILING
SIMPSON A35 OR LTP4
AT 1'-6" MAXIMUM
2X6 BEARING
WALL AT 1'-4"
SHEARWALL SEE PLAN
AND SCHEDULE
RE: PLAN FOR
HEADER
ROOF SHEATHING
SEE PLAN
TRUSS BLOCKING AT 4'-0"
EDGE NAILING
SIMPSON A35 OR LTP4
AT 1'-6" MAXIMUM
2X6 BEARING
WALL AT 1'-4"
SHEARWALL SEE PLAN
AND SCHEDULE
EDGE NAILING
ROOF SHEATHING
SEE PLAN
ROOF TRUSS
SEE PLAN
SETS OF (2) SIMPSON
LTP5 AT 2'-0" O.C.
1/2" PLYWOOD AT
EACH FACE OF SHEARWALL
DOUBLE ROOF
TRUSS
ROOF TRUSS
SEE PLAN
2x6 LOAD BEARING
WALL ABOVE
VARIESRE: ARCH
12
ROOF SHEATHING
SEE PLAN
SIMPSON
H2.5 CLIP
ROOF TRUSS
SEE PLAN
ROOF SHEATHING
SEE PLAN
LVL ROOF JOIST
SEE PLAN
11 7/8" LEDGER
X CONT. WITH SETS
OF (3) 1/4" SIMPSON SDS
SCREWS AT EACH STUD
2x6 STUD WALL
SIMPSON
H2.5 CLIP
ROOF SHEATHING
SEE PLAN
LVL ROOF JOIST
SEE PLAN
11 7/8" LEDGER
X CONT. WITH SETS
OF (3) 1/4" SIMPSON SDS
SCREWS AT EACH STUD
2x6 STUD WALL
ROOF TRUSS
SEE PLAN
RE: ARCH
12
ROOF TRUSS
SEE PLAN
ROOF SHEATHING
SEE PLAN
PROJ. NO.
DRAWN:
CHECKED:
DATE:
REVISIONS
SCALE:
SHEET TITLE:
ISSUED
FOR:
APPROVED:
3560 WALNUT ST. UNIT A
DENVER, CO 80205
PHONE 303.758.3800
© NEO STUDIO
2/22/2023 5:08:56 PM3/4" = 1'-0"HAYMEADOWBUILDING D91 MT. HOPE CIRCLEEAGLE, COLORADO21008177.00
CLH
JIN
11/17/22
PERMIT
ROOF FRAMING
SECTIONS
S4.01
JIN
3/4" = 1'-0"
SECTION4
3/4" = 1'-0"
SECTION6
3/4" = 1'-0"
SECTION1 3/4" = 1'-0"
SECTION2 3/4" = 1'-0"
SECTION3 3/4" = 1'-0"
SECTION5
3/4" = 1'-0"
SECTION7
3/4" = 1'-0"
SECTION8 3/4" = 1'-0"
SECTION9 3/4" = 1'-0"
SECTION10
3/4" = 1'-0"
SECTION11
3/4" = 1'-0"
SECTION12
3/4" = 1'-0"
SECTION13 3/4" = 1'-0"
SECTION14 3/4" = 1'-0"
SECTION15
3/4" = 1'-0"
SECTION16
1 02/22/2023 BLDG. DEPT.
RESPONSE AND
REVISIONS
1 1 1
1
1
1
1
11
1
1
1 C3/4" = 1'-0"
SECTION17 3/4" = 1'-0"
SECTION18 3/4" = 1'-0"
SECTION19 3/4" = 1'-0"
SECTION20
1111