    HomeMy WebLinkAbout170 Sam Grange Ct - 239122204003 - 1438-94ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT 
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION 
PD. Box 179 - 500 Broadway - Eagle, Colorado 31631 & 
blo 
Telephone:328-8755 -7q7 
YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. 
Please call for final inspection before covering any portion of installed system. 
PERMIT NO. 1438 
OWNER: James B. Milkovich PHONE: 963-1762 
MAILING ADDRESS: P.O. BOX 322 city: Carbondale stece: CO zlp: 81623 
APPLICANT: same 
Sam Grange Co rt PHONE: 
SYSTEM LOCATION: Lot #3, Summit Aspen Mnt. View IIT�xPARCELNUMBER: 2391-222-04-003 
LICENSED INSTALLER: sSme Dorais Excavation, Inc., Bill Dorais LICENSENO. 71-95 
DESIGN ENGINEER OF SYSTEM: Enartech, Inc. , Peter Belau 
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 
1250 GALLON SEPTIC TANK 
ABSORPTION AREA REQUIREMENTS: 
SQUARE FEET OF SEEPAGE BED 1207 SQUARE FEET OF TRENCH BOTTOM. via 34 infiltrator units 
SPECIAL REQUIREMENTS: Install as Der engineer's des i n revision dated 11-9-95 with the followin 
provisions: compaction o pipe runs, gravel -less design, inspection portals in eac trenc , 
and scarify any smeared surfaces Engineer is responsible for final•insnection. 
ENVIRONMENTAL HEALTH APPROVAL: 
CONDITIONS: 
DATE: November 9,1995 
1. ALL INSTALLATIONS MUST COWY WITH ALL RE9!!�REME_ NT_ g Q��TY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT 
TO AUTHORITY GRANTED IN 25. 10. 104. 1973. AS AMENDED. 
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION 
TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A 
REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. 
FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): 
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED 
PRIOR TO COVERING ANY PORTION OF THE SYSTEM. 
INSTALLED ABSORPTION OR DISPERSAL AREA: 1224 SQUAREFEET. via 34 Blodiffusers 
INSTALLED SEPTIC TANK: 1250 GALLON DEGREES FEET FROM ca a a c bu i- t s 
SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND 
PROPER MATERIAL AND ASSEMBLY X YES —NO 
COMPLIANCE WITH COUNTY/ STATE REQUIREMENTS: X YES NO 
ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. 
COMMENTS: 
ENVIRONMENTAL HEALTH APPROVA( 
ENVIRONMENTAL HEALTH APPROVAL: 
APPLICANT / AGENT: 
(RE -INSPECTION IF NECESSARY) 
RETAIN WITH RECEIPT RECORDS 
_ OWNER: 
RECEIPT # 
DATE: January 8 1996 
DATE: 
PERMIT 
PERCOLATION TEST FEE 
CHECK# 
Incomplete Applications -Will NOT Be Accepted 
(Site Plan MUST be attached) 
ISDS Permit # J q W0/y 
Building Permit # 
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT 
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY 
P. O. BOX 179 
EAGLE, CO 81631 
328-8755/927-3823 (Basalt) 
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 
* * 
* MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" 
************************************************************************** 
PROPERTY OWNER: 4,MF-S �• 1`6 t t �K ©ucGt� 
MAILING ADDRESS: CAPc?-�DaL'F-- Q-0 �1kQ PHONE: (4-t-w02 - 
APPLICANT/CONTACT PERSON: SAME. PHONE: 
e7LICENGSED S'ZSTEMS CONTRACTOR: Mtlh—yv'c-+} PHONE: �63-176L 
P 
COMPANY / DBA : - c--5 &y ADDRESS: � b • e"iC 3 L2- CA-V 1D (-E- C� 81 L 
PERMIT APPLICATION IS FOR: (NEW INSTALLATION ( ) ALTERATION ( ) REPAIR 
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: 
Legal Description: �0-r3 P,1ttJ63 SMMiT ASP Do KyU0-1A10 -CUJ 
Tax. Parcel Number: 2.391--222- 04- 003 Lot Size: �•C�52 
Physical Address: Q17O SAM Ca�� LSJV�T CA1�tr� 
BUILDING TYPE: (Check applicable category) 
(1-y- Residential/Single Family Number of Bedrooms 
( ) Residential/Multi-Family* Number of Bedrooms 
( ) Commercial/Industrial* Type 
TYPE OF.WATER SUPPLY: (Check applicable category) 
Well ( ) Spring ( ) l �tf Surface 1 , ' I t 
( ) Public Name of Supplier: 4c 3 oyu'i' 4t V," HOMfr�vwAU� ASS,vc- . 
*These system require design by a R gistered Professional Engineer 
SIGNATURE: Date: If-/61-9V 
************************************************************************** 
AMOUNT PAI . RECEIPT #:� DATE: I� 
CHECK #: _�a� CASHIER: 
Community Development Department 
(970)328-8730 
Fax: (970) 328-7185 
TDD: (970) 328-8797 
EAGLE COUNTY, COLORADO 
December 29, 1995 
James B.Milkovich 
P.O. Box 322 
Carbondale, CO 81623 
Eagle County Building 
P.O. Box 179 
500 Broadway 
Eagle, Colorado 81631-0179 
RE: Final of ISDS Permit No. 1438-95 Parcel #2391-222-04-003. 
Property location: 0170 Sam Grange Court, Carbondale, CO.. 
Dear Mr. Milkovich, 
This letter is to inform you that the above referenced ISDS 
Permit has been inspected and finalized. Enclosed is a copy to 
retain for your records. This permit does not indicate 
compliance with any other Eagle County requirements. Also 
enclosed is a brochure regarding the care of your septic system. 
Be aware that later changes to your building may require 
appropriate alterations of your septic system. 
If you have any questions regarding this permit, please contact 
the Eagle County Environmental Health Division at 328-8755. 
Sincerely, 
Janet Kohl 
Environmental Health Department 
Eagle County Community Development 
ENCL: Information Brochure 
Final ISDS Permit 
cc: files 
Community Development Department 
(970)328-8730 
Fax: (970) 328-7185 
TDD: (970) 328-8797 
EAGLE COUNTY, COLORADO 
Date: November 9, 1995 
TO: Dorais Excavation, Inc. 
Eagle County Building 
P.O. Box 179 
500 Broadway 
Eagle, Colorado 81631-0179 
FROM: Environmental Health Division 
RE: Issuance of Individual Sewage Disposal System 
Permit No. 1438-94, Tax Parcel #2391-222-04-003. 
Property Location: Lot# 3 Aspen Mountain View 
Subdivision, 0170 Sam Grange Court. Milkovich 
residence. 
Enclosed is your ISDS Permit No. 1438-94. It is valid for 120 
days. The enclosed copy of the permit must be posted at the 
installation site. Any changes in plans or specifications 
invalidates the permit unless otherwise approved. 
Systems designed by a Registered Professional Engineer must be 
certified by the Engineer indicating that the system was 
installed as specified. Eagle County does not perform final 
inspections on engineer designed systems. Your TCO will not be 
issued until our office receives this certification. 
Permits issued before November 15, 1995 must be completed by 
December 1, 1995. 
Permit specifications are minimum requirements only, and should 
be brought to the property owner's attention. 
This permit does not indicate conformance with other Eagle County 
requirements.. 
If you have any questions, please feel free to contact the 
Environmental Health Division at 328-8755. 
cc: files 
ENARTECH Inc., Peter Belau 
COMMUNITY DEVELOPMENT 
DEPARTMENT 
(303)328-8730 
EAGLE COUNTY, COLORADO 
December 2, 1994 
James B. Milkovich 
P.O. Box 322 
Carbondale, CO 81632 
Dear Applicant, 
500 BROADWAY 
P.O. BOX 179 
EAGLE, COLORADO 81631 
FAX: (303) 328-7185 
The Environmental Health Division would like to notify you to 
make a formal request to extend your Individual Sewage Disposal 
System(ISDS) Permit #1438-94 into the 1995 construction year•. 
The Environmental Health Division discontinued percolation tests 
on November 15, 1994 and final inspections on December 2, 1994 
due to climatic conditions. 
ISDS permits are active for 120 days after the date of issue if 
no Building Permit has been issued for the same property. If a 
Building Permit has been issued for the same property the ISDS 
will expire at the same time as the building permit. 
If you still plan to apply for a Building Permit this year or in 
the early months of 1995 you will need to have a percolation test 
conducted before your Building Permit will be released. You will 
have to contact a Registered Professional Engineering(RPE) firm 
to conduct your percolation test. 
If you have had your permit issued and have not had your final 
inspection completed, but plan on constructing the system in the 
next few weeks, please give our office a call and we will 
evaluate your permit on a case by case situation. 
Please give the Environmental Health office a call at 328-8755, 
if you have any questions regarding your permit extension 
process. 
cc: ISDS Permit #1438-94 File 
Community Development Department 
(970)328-8730 
Fax: (970) 328-7185 
TDD: (970) 328-8797 
EAGLE COUNTY, COLORADO 
December 12, 1995 
Dear Applicant, 
Eagle County Building 
P.O. Box 179 
500 Broadway 
Eagle, Colorado 81631-0179 
The Environmental Health Division would like to notify you to 
make a formal request to extend your Individual Sewage Disposal 
System(ISDS) Permit #1433�4into the 1996 construction year. The 
Environmental Health Division discontinued percolation tests on 
November 15, 1995 and final inspections on December 2, 1995 due 
to climatic conditions. 
ISDS permits are active for 120 days after the date of issue if 
no Building Permit has been issued for the same property. If a 
Building Permit has been issued for the same property the ISDS 
will expire at the same time as the building permit. 
If you still plan to apply for a Building Permit this year or in 
the early months of 1996 you will need to have a percolation test 
conducted before your Building Permit will be released. You will 
have to contact a Registered Professional Engineering(RPE) firm 
to conduct your percolation test. 
If you have had your permit issued and have not had your final 
inspection completed, but plan on constructing the system in the 
next few weeks, please give our office a call and we will 
evaluate your.permit on a case by case situation. 
Please give the Environmental Health office a call at 328-8755, 
if you have any questions regarding your permit extension 
process. 
cc: ISDS Permit # File 
ENARTECH Inc. Consulting Engineers and Hydrologists 
October 4, 1995 
Mr. Jim Milkovich 
P.O. Box 322 
Carbondale, CO 81623 
RE: Lot 3, Aspen Mountain View Subdivision , 
Dear Jim: 
This letter is to provide design recommendations for the individual sewage disposal system for 
the proposed residence located at 0170 Sam Grange Court, which is Lot 3 of Aspen Mountain 
View Subdivision in Eagle County. 
The design of the proposed sewage disposal system is based upon soils percolation testing and 
soils investigation work performed by Hepworth-Pawlak Geotechnical. A copy of Hepworth- 
Pawlak Geotechnical's soils investigation report is enclosed, along with a copy of my design 
calculations. The geotechnical investigation indicates a soil percolation rate of 45 minutes per 
inch; therefore, a standard leachfield system is appropriate for the site. The recommended 
sewage disposal system consists of a 1,250-gallon septic tank and a 1,200 square foot 
leachfield. An alternative leachfield is 32 "Infiltrator" leachfield chambers installed in 
trenches (not in a bed). All construction work must be in conformance with Eagle County 
Individual Sewage Disposal System Regulations; a permit from Eagle County will be required. 
I will forward this information to Eagle County and to your system installation contractor by 
copy of this letter. 
Please give me a call if you have any questions in this regard. 
Sincerely, 
ENARTECH, INC. 
Peter Belau, P.E. 
PB/jlw 
Enclosure 
cc: r. Eagle County Environmental Health 
Bill Douray 
P342-06 (P342 01C)95 
302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (303) 945-2236 
ENA RTECH Inc. Consulting Engineers and Hydrologists 
October 20, 1995 
Dear Jim: 
Enclosed are the revised design calculations and the design drawings for the individual sewage 
disposal system for the proposed residence located at 0170 Sam Grange Court, which is Lot 3 
of Aspen Mountain View Subdivision in Eagle County. The revised design calls for a 
minimum 1,250-gallon septic tank and a minimum 1,207 square -foot leachfield. 
Please give me a call if you have any questions in this regard. 
Sincerely, 
ENARTECH, INC. 
Peter Belau, P.E. 
PB/jlw 
cc: Eagle County Environmental Health 
Bill Dorais 
P342-08 (P342 02C)95 
302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (303) 945-2236 
GIVHK I LL rl, INN. 
302 Eighth Street, Suite 325 
P.O. Drawer 160 
GLENWOOD SPRINGS, CO 81602 
(303) 945.2236 
Jut$ a__.y , I --Z E 421i^{ 1 "1 IN V l t-- L✓, J.. Z ]J 
SHEET NO. , r OF 
CALCULATED BY ;�% E Ly DATE j O— / S 
CHECKED BY DATE 
NEC —FIVER SEP 1 1 1995 
HEPWORTH-PAWLAK GEOTECHNICAL, INC. 
September 5, 1995 
Jim Milkovich 
P.O. Box 322 
Carbondale, Colorado 81623 
5020 Road 154 
Glenwood Springs, CO 81601 
Fax 970 945-8454 
Phone 970 945-7988 
Job No. 195 137 
Subject: Percolation Testing, Proposed Residence, Lot 3, Aspen Mountain View, 0170 
Sam Grange Court, Eagle County, Colorado. 
Dear Mr. Milkovich: 
As requested by you, Hepworth-Pawlak Geotechnical performed percolation testing at the 
subject site on August 29, 1995. The fmdings of our work are presented in this report. The 
foundation excavation for the residence was observed and recommendations provided in a report 
dated February 28, 1995, Job No. 195 137. 
Three percolation test holes were excavated and soaked by others prior to our site visit. The 
hand dug holes are located in the bottom of shallow backhoe pits. The percolation tests were 
performed on August 29, 1995. The profile pit was observed on September 1, 1995. 
The soils exposed in the profile pit consisted of about %2 feet of topsoil overlying basalt cobbles 
and boulders in a sandy clay matrix.. The results of percolation tests conducted at the site are 
presented in Table I. The test locations are shown on Fig. 1. The percolation rates averaged 
about 45 minutes per inch. Based on our fmdings, the tested site is suitable for a conventional 
infiltration septic disposal system. 
If we can be of further assistance, please do not hesitate to call our office. 
Sincerely, 
HF� W RTr P 
Z 
J rdy damson, 
Rev. By: 
JZA/ro 
Attachments 
0 REG 
24443 
717/s f 
CHNICAL, INC. 
cc: Enartech - Attn: Chuck Peterson 
Scale 1 " = 40' 
6 Percolation Test Holes 
2 Profile Pit 
I 
I 
I 
I 
HEPWORTH-PAWLAK I 
195 137 GEOTECHNICAL, Inc. ( Locations of Percolation Test Holes Fig. 1 
HEPWORTH-PAWLAK GEOTECHNICAL, INC. 
TABLE I Job No. 195 137 
HOLE NO. 
HOLE DEPTH 
(INCHES) 
LENGTH OF 
INTERVAL 
(MIN) 
WATER DEPTH 
AT START OF 
INTERVAL 
(INCHES) 
WATER DEPTH 
AT END OF 
INTERVAL 
(INCHES) 
DROP IN 
WATER 
LEVEL 
(INCHES) 
AVERAGE 
PERCOLATION 
RATE 
(MIN./INCH) 
P-1 
45 1 /2 
20 
12 1 /4 
10 3/4 
1 1/2 
40 
10 3/4 
10 
3/4 
10 
9 1/2 
1/2 
9 1/2 
9 
1/2 
9 
8 1/2 
1/2 
8 112 
8 
1/2 
P-2 
49 1 /4 
20 
13 3/4 
13 
3/4 
48 
13 
12 1/2 
1/2 
12 1/2 
12 
1/2 
12 
11 1/2 
1/2 
11 1/2 
11 1/4 
1/2 
11 1/4 
10 3/4 
1/4 
P-3 
46 1/4 
20 
i 
10 1/4 
9 3/4 
112 
48 
9 3/4 
9 
3/4 
9 
8314 
1/4 
8 3/4 
8 1/4 
1/2 
8 1/4 
8 
1/4 
8 
7 1/2 I 
1/2 
Notes: Percolation holes were dug and soaked by others. The percolation tests were conducted on August 29, 
1995. 
ENARTECH ►nc. Consulting Engineers and Hydrologists 
November 9, 1995 
Mr. Jim Milkovich 
P.O. Box 322 
Carbondale, CO 81623 
RE: Lot 3; Aspen Mountain View Subdivision 
Dear Jim: 
The design of the proposed individual sewage disposal system for Lot 3 of Aspen Mountain 
View Subdivision in Eagle County (0170 Sam Grange Court) should be modified in 
accordance with the enclosed sketch. The modified design calls for a minimum of 34 standard 
Infiltrator or Biodiffuser leachfield chambers in trenches with a serial distribution system 
rather than a leachfield bed as shown in the previous Enartech design drawing dated 10/20/95. 
These trenches must have a minimum of 6 feet of separation, and each trench and its 
distribution pipe should be installed 4 inches lower in elevation than the adjacent trench to 
allow serial distribution. The number of Infiltrator or Biodiffuser chambers is calculated as 
follows: (1207 sq. ft. absorption area) x (0.5)/(18 sq. ft. per chamber) = 33.5. The sewage 
disposal system should be installed as per the previous (10/20/95) design drawing with the 
modifications to the soil absorption system on the Site Plan as per the enclosed sketch. 
I cannot modify the previous design drawing at this time because my computer system is not 
functioning. I will modify the design drawing after the system is installed and inspected as an 
"As -Built" drawing. 
Please give me a call if you have any, questions in this regard. 
Sincerely, 
ENARTECH, INC. 
Peter Belau, P.E. 
PB/jlw 
Enclosure 
cc: 4 Eagle County Environmental Health 
Bill Dorais 
P342-08 (P342 03C)95 
302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (303) 945-2236 
1438-94 MILKOVICH 
Ji 
LOT # ASPEN MOUNTAIN VIEW III 
JOB LOCATION 
-6P�aI7? 
JOB NO, 
I 
DATE STARTED 
DATE COMPLETED 
DATE, BILLED 
WIN, 
1 f/mm-m 1-, 94 M, , -, N �A� E I 
WIME 
I 
I �j 
-'" 
& � I 
lslm" N-/" 
OUR R .�f�/�.� 
/ .i1�JOB 
CdST SUMMARY 
III 
wwmn 
TOTAL 
r■ 
TOTAL MATERIAL! 
�-x'mr, N 
®■ 
MISC. COSTS 
mtr,,�. ' 
. �. 
��.� ram.. 
®■ 
TOTAL JOB C OST 
®■ 
i 
GROSS PROFIT 
M-E � I 
COSTS1 
LESS OVERHEAD 
% OF SELLING --�NET 
PROFIT 
JOB FOLDER Product 278 Q® NEW ENGLAND BUSINESS SERVICE. INC., GROTON, MA 01471 JOB FOLDER 
Printed in U.S.A. 
�S 
Y 
;._•-.1r7EMNNEWUNAL- - NO. ii6A•24X36-1- 
r 
DRAWN 
CHECKEDi 
DATE 
SCALE 
1 - 2D, 
JOB NO. 
SHEET 
OF a SHEETS 
MINIMUM 10' SETBACK BETWEEN 
LEACHFIELD AND PROPERTY LINES 
PROPOSED 
RESIDENCE 
4" CLEANOUT 
FLEXIBLE 
COUPLING 
4-INCH PVC SEWER PIPE FROM BUILDING 
AT MINIMUM 1/4-INCH PER FOOT SLOPE. 
MANHOLES WITH LIDS 6" 
BELOW FINISH GLADE 
MINIMUM 
9 250-GALLON CPLG. 
SEPTIC TANK 
FINISH GRADE 
DRAINAGE DIVERSION DITCH 
4' MNIMUM COVER 
p 
N 
O 
D 
CONSTRUCTION NOTES AND SPECIFICATIONS 
o 
� 00 
oo� 
0 
-1 
O 
U N 
� 
OZ� 
1. 
CONSTRUCTION SHALL CONFORM TO EAGLE COUNTY 
_ 
a0. 
SEWAGE DISPOSAL SYSTEM REGULATIONS. 
? 
a 
N o 0 
2. 
THE SYSTEM INSTALLATION CONTRACTOR SHALL HAVE AN 
�✓ 
W 
G O ti 
o 3" 
a 
EAGLE COUNTY_ LICENCE FOR INSTALLING DISPOSAL SYSTEMS. 
Z 
WJ`` 
3. 
THE EAGLE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT 
� 
W 
-�N 
AND THE DESIGN ENGINEER (ENARTECH, INC.) SHALL 
a' 
Z 
v �10 
BE NOTIFIED OF THE CONSTRUCTION PROGRESS SO THE 
Xo't 
SYSTEM MAY BE INSPECTED. DO NOT BACKFILL OVER 
:3 
00 °°-� 
THE LEACH FIELD UNTIL THE SYSTEM HAS BEEN 
JL 
0 
0 
INSPECTED. 
4. 
THE SEPTIC TANKS SHALL BE BEDDED AND INSTALLED 
IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMEN- 
DATIONS TO PREVENT SETTLEMENT. 
5. 
ALL PIPING SHALL BE BEDDED AND BACKFILLED WITH 
3/4" GRAVEL OR SELECT NATIVE SOIL WITH ROCKS 
REMOVED. COMPACT ALL BACKFILL. PIPING SHALL BE 
INSTALLED WATERTIGHT AND TO PREVENT FREEZING. 
6. LOCATIONS OF SEWAGE DISPOSAL SYSTEM COMPONENTS 
SHOWN ON THE SITE PLAN ARE APPROXIMATE. ACTUAL 
LOCATIONS ARE TO DETERMINED ON -SITE TO PROVIDE 
COMPATABLE GRADES, TO AVOID TREES, AND TO MINIMIZE 
DISTURBANCES. ALL APPLICABLE SETBACKS MUST BE MET. 
7. THE LEACHFIELD BED SHALL BE EXCAVATED IN NATURAL 
GROUND. NO PORTION OF THE BED SHALL BE PLACED 
ON FILL. 
8. SCARIFY OR RAKE THE BOTTOM OF THE BED TO LOOSEN 
ANY SMEARED OR COMPACTED SOIL AREAS. 
9. THE BOTTOM OF THE BED AND ALL DISTRIBUTION PIPING 
IN THE BED SHALL BE LEVEL.— -Y% o 
10. THE SIDES AND ENDS OF DISTRIBUTION PIPING IN THE 
LEACHFIELD SHALL BE 3' FROM THE EDGE OF THE GRAVEL. 
11. DO NOT COMPACT THE BACKFILL OVER THE LEACHFIELD. 
12. GRADE THE SURFACE OF THE LEACHFIELD AND ADJACENT 
AREAS TO DEFLECT RUNOFF WATER AWAY FROM THE 
LEACHFIELD. 
SYSTEM DESIGN CALCULATIONS 
1. DESIGN FLOW = (4 BEDROOMS)X(2 PERSONS/BR)X(75 GPD/ 
PERSON)X(1.5 PEAK FACTOR) = 900 GPD PjAc A&'4j� >� m 
2. FIELD PERCOLATION RATE = 45 MINUTES/INCHvju 
1/2 
3. CALCULATED SOIL ABSORPTION AREA = (900 GPD)X(45) /5 
1207 SO. FT. 
4. REQUIRED MINIMUM SEPTIC TANK SIZE = 1250 GALLONSt -��- 
0�_ 
BACKFILL WITH NATIVE SOIL, REMOVE LARGE ROCKS 
SAVE EXCAVATED TOPSOIL AND PLACE OVER ALL DISTURBED AREAS 
4" PVC ACCESS PORT NEAR CENTER OF 
LEACHFIELD TO BOTTOM OF GRAVEL. 
PAINT PIPE BLACK ABOVE GROUND 
CAP 
SLOPE TO DRAIN 
FILTER FABRIC OVER TOP OF GRAVEL 
2' MINIMUM COVER 
REVISION 
DATE BY 
BOTTOM OF BED SHALL BE LEVEL -- 
4-INCH PVC SEWER PIPE CAP ENDS OF PIPES 
AT MINIMUM 1 /4-INCH 4" SOLID PVC MANIFOLD PIPE, LEVEL DATE 
PER FOOT SLOPE. 
10/20/95 
4" PERFORATED PVC DISTRIBUTION PIPES AT 6' CENTERS, LEVEL (PERFORATIONS DOWN) SCALE 
V 3 7 E N P R (0 F D L E 
1" OR 1-1/2" WASHED GRAVEL FROM 6" BELOW PIPES TO 2" ABOVE PIPES 
ENGINEER 
P. BELAU 
DWG FILE 
ISDS-08 
JOB 
393-08 
SHEET 
it 
OF 1 SHEETS