HomeMy WebLinkAbout175 Lynns Ct - 239122204012 - 1428-94IS EXPIREDINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway - Eagle, Colorado 81631
Telephone: 328-8755
YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE.
Please call for final inspection before covering any portion of installed system.
OWNER: Marcy Bogner
PERMIT NO. 1428
PHONE: 927-8582
MAILING ADDRESS: P.O. Box 797 City: Basalt
State: CID Zip: 81621
APPLICANT: Same
PHONE: 927-4941
SYSTEM LOCATION:__ 0175 L nns Court TAX PARCEL NUMBER:
LICENSED INSTALLER: .Toe_ Zamora
DESIGN ENGINEER OF SYSTEM: hl�, / Schmueser Gordon M
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
1000 GALLON SEPTIC TANK
ABSORPTION AREA REQUIREMENTS:
SQUARE FEET OF SEEPAGE BED 600 SQUARE FEET OF TRENCH BOTTOM.
SPECIAL REQUIREMENTS: Install as per engineer's design; however
cleanouts at the end of each trench.
ENVIRONMENTAL HEALTH
91-222-09-012
E No: 05-94
rake trench sidewalls, and install
DATE: September 13,1995
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS. ADOPTED PURSUANT
TO AUTHORITY GRANTED IN 25. 10. 104. 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION
TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A
REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS. ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED.
FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED
PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET.
INSTALLED SEPTIC TANK: GALLON DEGREES
FEET FROM
SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND
PROPER MATERIAL AND ASSEMBLY —YES —NO
COMPLIANCE WITH COUNTY / STATE REQUIREMENTS: _ YES _ NO
ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A REANSPECTION WHEN WORK IS CORRECTED.
COMMENTS:
ENVIRONMENTAL HEALTH APP
ENVIRONMENTAL HEALTH APP
PPLICANT I AGENT:
ERMIT FEE
PERCOLATION TEST FEE
(RE -INSPECTION IF NECESSARY)
RETAIN WITH RECEIPT RECORDS
OWNER:
RECEIPT #
CHECK# —
DATE:
ISDS Permit ,_ !`l M q
Building Permit ,
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE-- EAGLE COUNTY
P.Q. BOX 179
EAGLE, CO 81631
328-8755/927-3823(Basalt)
PERMIT APPLICATION FEE $1.50.00 PERCOLATION TEST FEE $200.0c
PROPERTY OWNER: ���c �� F ©GtjC�,
MAILING ADDRESS : R D t)
APPLICANT/CONTACT PERSON: S,0
LICENSED SYSTEMS CONTRACTOR:
Joe Z
ADDRESS; 19 9S3 9 4 C4kS0J0gLr pHoNLY. 163 .,.i
PERMIT APPLICATION IS FOR: 01 NEW INSTALLATION ( ) ALTERATION (j REPAIR
LOCATION OF PROPOSED•INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description: �� �n �� f—i4 c, As P_rJ / -F q; CK)
Parcel Number: �.�� ��. r1L;PJCs NO,�
S i ll�\-Lot size:
�5'r
Ach'dtewn Physical Address: 019� L tiN-S Gj ti' Ae5odgE11,C C6a�
BUILDING TYPE: (Check applicable Category)
(Vf Residential / Single Family Number of Bedrooms
( ) Residential / Multi -Family* Number of Bedrooms
( ) Commercial / Industrial* Type
TYPE 'OF WATER SUPPLY:
Weli(kl' Spring ( ) Surface ( )
Public ( ) Name of Supplier:
*These systems require design by a Registered Professional Engine,!r
NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION
MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
14 f
SIGNATURE: DATE:
�tylrie'dk�k�eir�ie94*�r7k*ir'*'�Cy1rLt7,t�4't)ir7t�Cyk�C�t�c �e9e�k9r�k'9eok4t***yk�*�e�F'*�e�k�c3r*�k�e�krok�9c•*�k*�F7ti'*�k**'�ekk�ro4�Fkde�e•*
AMOUNT PAID: l —0� c
—RECEIFT# DATE:
��� � Iq 1
—
CfiECik CASHIER •
... .. ... , ' � , ! g'.Y,Y'cy''�� ri:�.*•. .�,,:�r1.rie a r;yta-,r' 't' rrX�, 7 c�
Community Development Department
(970) 328-8730
Fax: (970) 328-7185
TDD: (1970) 328-8797
EAGLE COUNTY, COLORADO
Date: September 13, 1995
TO: Zamora Excavating
FROM: Environmental Health Division
4e
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Issuance of Individual Sewage Disposal System
Permit No. 1428-94 Tax Parcel #2391-222-09-012
Property Location: 0175 Lynns Court, Carbondale,
CO, Bogner residence.
Enclosed is your ISDS Permit No. 1428-94.It is valid for 120
days. The enclosed copy of the permit must be posted at the
installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved.
Systems designed by a Registered Professional Engineer must be
certified by the Engineer indicating that the system was
installed as specified. Eagle County does not perform final
inspections on engineer designed.systems. Your TCO will not be
issued until our office receives this certification.
Permit specifications are minimum requirements only, and should
be brought to the property owner's attention.
This permit does not indicate conformance with other Eagle County
requirements.
If you have any -questions, please feel free to contact the
Environmental Health Division at 328-8755.
cc: files
Nelson Environmental & Wastewater Solutions Ltd
E Property Address: 0175 Lynns Court
W
S Legal Description: Lot 12, Aspen Mountain View, Filing #3
Property Owner:
Name Marcy Bogner
Address P. O. Box 797, Basalt, CO 81621
Phone 927-0619
Contractor: Excavating Contractor:
Name Unknown. Name Zamora Excavating
Address AddressP. O. Box 574
Carbondale, CO 81623
Phone Phone 963-1399
Saturation and Swelling
o Smeared surfaces removed X Yes
o Gravel Added X Yes
o Date and Time presoak water added
10/3/94 A 10:00 a.m.
o Amount of presoak water added
30 gallons /hole
o Water remaining in holes after presoak?
Hole 1: Yes x No
Hole 2: Yes x No
Hole 3: Yes x No
Percolation Rate Measurement
Hole 1: 16 minutes/inch
Hole 1: 15 minutes/inch
Hole 3: 18 minutes/inch
AVERAGE 17 minutes/inch
Groundwater:
o Not Encountered to 8 ft.
o Estimated depth to high seasonal
water if not encountered 180 feet
o Is area believed to be subject to
seasonal fluctuations which could
result in a seasonal water table?
_ Yes X No
Slope in absorption area
10% to the SSE
Bedrock
o Not Encountered
o Estimated depth if not encountered-50 ft.
o Type of bedrock:
Sandstone Claystone
Siltstone X Other:Basalt
X Fractured Weathered
o Is bedrock believed to be permeable?
X Yes No
I certify that the above information is correct and complete to the best of my knowledge
and that all tests were performed in accordance with the provisions of Eagle County
Individual Sewage Disposal System Regulations, Section 4.05.01 through 4.05.08.
Robert F. Nelson
President
P.O. Box 6961 Snowmass Village, CO.81615 Office (303) 923.3289 Home (303) 923.2766
Nelson Environmental & Wastewater Solutions, Ltd
E
W December 2, 1994
S Ms. Marcy Bogner
P. O. Box 797 _
Basalt, CO 81621
Subject: Soils Evaluation and Percolation Tests for Individual Sewage System Design for Lot 12,
the Summit, Filing 3, Aspen Mountain View Subdivision, Eagle County, CO at 0175 Lynn's Court
Dear Marcy,
As requested, Nelson Environmental and Wastewater Solutions, Ltd., performed a soils study and
percolation tests to recommend a design for a septic system for the proposed residence. We
conducted this study according to Sections 4.04 and 4.05 , Chapter IV (Individual Sewage
Disposal Systems) of the Eagle County Code on October 3, 1994. We have based our
recommendations on the subsurface conditions encountered. You should furnish this letter and
the completed engineering plans to the Eagle County Environmental Health Department to obtain
a permit to construct this individual sewage system.
Proposed Construction:
This planned residence is a three bedroom, two bathroom, two-story house.
The approximate location of the proposed residence and sewage disposal field are shown on
Figure 1. Without water conserving toilets, the ultimate wastewater flow from this residence is
estimated to be 450 gallons per day (GPD).
Site Conditions:
The investigated site is a vacant 1.611-acre lot in the Aspen. Mountain View Subdivision on
B Missouri Heights. ecau- se of the plat recording, on -site sewage disposal systems within this
subdivision are required to be designed by a registered professional engineer. We refer you to
Dan Cokley of Schmeuser, Gordon and Meyer Engineering in Glenwood Springs (945-1004) for
this site -specific septic system design. In order to complete the septic system design, please
provide him a completed site plan as soon as possible.
The property i.s served by subdivision wells. The ground surface, which appears natural in the
proposed area of the absorption field, slopes to the Southeast at a 10% grade. There was a
typical vegetation pattern of oak brush, sagebrush, and grasses and over the property. There is a
large irrigation ditch bordering the southerly property line. Also, a rather deep ravine that appears
to be an abandoned irrigation ditch crosses the lot from the North to the West. We understand
that this ravine is to be filled with the soil from the house excavation.
P.O. Box 6961 Snowmass Village, CO.81615 Office (303) 923.3289 Home (303) 923, 2766
Bogner Property
Septic System Site Evaluation
December 2, 1994
Page 2
Subsurface Conditions:
A soil profile pit, within 25 feet of the proposed absorption area, was excavated to a depth of
seven and one-half feet. No ground water was encountered in the profile excavation. Bedrock
was not present within profile pit. The soil textures encountered were a silty clay topsoil about
eighteen inches deep, and a noncalcareous, reddish sandy clay to the bottom of the profile hole.
Percolation Testing:
The subsurface soil conditions were evaluated with the standard percolation test procedures at the
approximate location shown on Figure 1. The test holes were hand dug in the bottom of shallow
backhoe excavations to a depth of thirty-nine to forty-five inches below the ground surface. The
subsoil in which the percolation testing was run, consisted of sandy clay or clay loam. This soil
was well consolidated, and showed little tendency to swell. However, smearing or compaction
caused by the excavating equipment was observed in the backhoe excavations.
Percolation testing was performed in the proposed absorption area South of the building site. The
percolation holes were hand dug in the location of the proposed absorption field at the bottom of
backhoe excavations prepared earlier. Three inches of gravel were placed in the bottom of each
hole. The percolation holes were pre-soaked the evening before the percolation testing by adding
five gallons of water to each hole. Water was then added approximately every two hours for six
hours before beginning the percolation test.
The results of the percolation testing are presented in Table I. These results indicate the clay
loam soils have an average percolation rate of 17 minutes per inch and are acceptable for an
infiltration design for the on -site sewage system. There was little variability in the percolation test
measurements over the reading periods.
Minimum Eagle County Requirements:
The soils and terrain in the area of the proposed building do not present any significant limitations
to the construction of an on -site sewage disposal system. The minimum Eagle County
requirements for this installation are based on a system loaded at an average of 450 gallons per
day. This flow would require a septic tank with a volume of at least 1000 gallons and a minimum
of 700 square feet of standard absorption trench.
It. is important to maintain a setback of at least 50 feet from the absorption field to the large
irrigation ditch on the South property line.
Bogner Property
Septic System Site Evaluation
December 2, 1994
Page 3
Limitations: This report has been prepared according to generally accepted practices in this area
for use for sewage disposal design purposes. The conclusions and recommendations submitted in
this report are based upon data obtained from our site visits at the location indicated. There is
some possibility that the nature and extent of variations in the subsurface soils across the site may
not have been evident at the time of this investigation, and may need additional evaluation if
further excavation reveals conditions different from those described. This office should be
advised of any unusual situations as soon as possible so we may reevaluate our recommendations.
If you have questions or if we may be of further assistance, please call the office.
Sincerely,
A��AIZ4—
Robert F. Nelson
President
Attachments
cc: Dan Cokley
Schmeuser, Gordon, Meyer, Engineers
p `
Nelson Environmental & Wastewater Solutions Ltd:
_E
W
TABLE I
S
PERCOLATION TEST RESULT FORM
Hole Length Depth at Depth at Drop in Average
Hole Depth of Interval Start of Interval End of Interval Water Level Percolation
No. (in.) (Mnutes) (Inches) (Inches) (Inches) Rate(Min./Inch)
1 45 10
7 9/16
6 15/16
5/8
10
6 15/16
6 3/8
9/16
10
6 3/8
5 3/4
5/8
10
5 3/4
5 1/8
5/8
10
51/8
41/2
5/8 16
2 41 10
8 1/8
7 3/8
3/4
10
7 3/8
6 3/4
5/8
10
6 3/4
6 1/16
11/16
10
6 1/16
5 7/16
5/8
10
5 7/16
4 3/4
11/16 15
3 45 10
8 3/4
8 3/16
9/16
10
8 3/16
7 9/16
5/8
10
7 9/16
7
9/16
10
7
6 3/8
5/8
10
6 3/8
5 13/16
9/16 18
Marcy Bogner Property
Lot 12, Aspen Montain View, Filing 3
0175 Lynns Court
r� .� ...rn ...,.�,..:.... ter,......
I n/M lnn
COMMUNITY DEVELOPMENT
DEPARTMENT
(303)328-8730
EAGLE COUNTY, COLORADO
December 2, 1994
Marcy Bogner
P.O. Box 797
Basalt, CO 81621
Dear Applicant,
500 BROADWAY
P.O. BOX 179
EAGLE, COLORADO 81631
FAX: (303) 328-7185
The Environmental Health Division would like to notify you to
make a formal request to extend your Individual Sewage Disposal
System(ISDS) Permit #1428-94 into the 1995 construction year.
The Environmental Health Division discontinued percolation tests
on November 15, 1994 and final inspections on December 2, 1994
due to climatic conditions.
ISDS permits are active for 120 days after the date of issue if
no Building Permit has been issued for the same property. If a
Building Permit has been issued for the same property the ISDS
will expire at the same time as the building permit.
If you still plan to apply for a Building Permit this year or in
the early months of 1995 you will need to have a percolation test
conducted before your Building Permit will be released. You will
have to contact a Registered Professional Engineering(RPE) firm
to conduct your percolation test.
If you have had your permit issued and have not had your final
inspection completed, but plan on constructing the system in the
next few weeks, please give our office a call and we will
evaluate your permit on a case by case situation.
Please give the Environmental Health office a call at 328-8755,
if you have any questions regarding your permit extension
process.
cc: ISDS Permit #1428-94 File
1411 jclq
--___.-_____H _.
�t.IA
j 1i T, Cl S C 0 A S ✓� c� r.C�
Community Development Department
(970) 328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
December 12, 1995
Dear Applicant,
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
The Environmental Health Division would like to notify you to
make a formal request to e�ctend your Individual Sewage Disposal
System(ISDS) Permit #/40-yg5into the 1996 construction year. The
Environmental Health Division discontinued percolation tests on
November 15, 1995 and.final inspections on December 2, 1995 due
to climatic conditions. .
ISDS permits are active for 120 days after the date of issue if
no Building Permit has been issued for the same property. If a
Building Permit has been issued for the same property the ISDS
will expire at the same time as the building permit.
If you still plan to apply for a Building Permit this year or in
the early months of 1996 you will need to have a percolation test
conducted before your Building Permit will be released. You will
have to contact a Registered Professional Engineering(RPE) firm
to conduct your percolation test.
If you have had your permit issued and have not had your final
inspection completed, but plan on constructing the system in the
next few weeks, please give our office a call and we will
evaluate your permit on a case by case situation.
Please give the Environmental Health office a call at 328-8755,
if you have any questions regarding your permit extension
process.
cc: ISDS Permit #iq�&-`i�-File
'Am k 1,� Co���l
i
e-�fCAa /-'I 7 S D S �� 14'
kin L �,oj --
6ar Sa
rr
m � �l s 0 G /i c (Z'
F'o. bob �l1
51kSAUi co
110- 9-'q- 9SFS2-
1428-94 BO.GNER Marcy J.
JQB NAME Lot 12 Filing 3 Oak Ridge III Aspen Mtn JOB NO,
0175 Lynn's Court
9gQ1-999_niA"
TION
BILL TO
DATE STARTED
DATE COMPLETED
DATE. BILLED
lz�h
q/M 7q I -h !��Z42r��
JOB COST SUMM Y
TOTAL SELLING PRICE
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 278 �® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB FOLDER Printed in U.S.A.
.r
t
PLUG
NOTE.• CLEANOUT TO BE LOCATED AT
ALL HORZ/VERT CHANGES IN DIRECTION
FLOW 1
45 PVC -
4" PVC WYE OR
ELBOW
CLEAN -OUT DETAIL-,
45 PVC
El80W
FLOW
4" TEE (REMOVE FOR INSPECTION)
4" PVC
12" I &W. COVER
N
NOTE. INSTALL INFILTRATOR
PER MANUFACTURER'S
REQUIREMENTS AND/OR
RECOMMENDATIONS.
NATIVE BACKFILL
4" NO
BOTTOM OF TRENCH
3.0'
COUPLING
INF/L TRA TOR SHELL
NfIL TRA TOR SECT/ON
N. T. S.
GENERAL NOTES. -
DESIGN CALCULATIONS
BOGNER I.S.D.S. I. All materials, installation practices, setback
EAGLE COUNTY, COLORADO requirements, etc., shall comply with the Eagle County
Individual Sewage Disposal System Regulations.
1. DESIGN PERCOLATION RATE (NATIVE) = 17 MINUTES/INCH The absorption trench shall .be constructed so that the
BY NELSON ENVIRONMENTAL, 10/3/94 bottom level +/— 0.1 inches. Place trench in_ natural ground;
2. 3 BEDROOM HOUSE DESIGN. no portion of `the trench shall be placed in fill. Provide
2 PERSONS PER BEDROOM positive drainage away from the trench.
75 GALLONS PER PERSON DAY
J. 7he location of the trench may be field adjusted to better
3. DETERMINE AVERAGE DAILY FLOW: fit the site, provided a// setbacks are met, and Health Officer
and Engineer are notified.
Q = (3)(2)(75) = 450 GALLONS PER DAY
� 4. Piping to system shall be 4" ASTM 2729 PVC pipe.
4. DESIGN FLOW AT 150% PEAKING FACTOR: 1
5. The area disturbed by construction shall be reseeded with
Q = 450 (1.5) = 675 GALLONS PER DAY �x native grasses to prevent erosion.
5. SEPTIC TANK CAPACITY: 6. Use risers as needed to bring septic tank access hatch
r\� within 6" of. finished grade.
30 HOURS DETENTION 675 GALLONS PER DAY) = 844 GALLONS �D
24 HOURS PER DAY /ry 7ASTM 3034 PVC pipe or pipe of equal strength or other pipe
proper/y supported to prevent failure by settling shall extend
USE 1000 GALLON SEPTIC TANK PER CODE MINIMUM from from tank for a distance of at least five feet (5) from
the inlet and outlet ends.
6. SIZE ABSORPTION AREA:
S. The Contractor and Owner shall take whatever measures
A (NATIVE) _ (Q)(SQRT(T)) WHERE: Q= PEAK DESIGN FLOW are necessary to assure that a} the septic tank and
5 A= ABSORPTION AREA y; sewer lines are completely water tight to prevent
DSQ.FIT.
RCOLATION RATE �� - infiltration of groundwater into the system, and
b) the system is installed to prevent freezing of
A (NATIVE) = t675)(SQRT(17)) 556.6'� Irj x � gravity sewer lines.
5
`7 9. The County Health Officer and Engineer shall be notified when
construction commences and kept abreast of the construction
THE ABOVE ABSORPTION AREA REPRESENTS THE AREA NECESSARY progress so that sufficient inspection can be performed to
FOR A TRENCH TYPE SYSTEM. assure conformance with these plans.
7. ADJUSTMENTS TO ABSORPTION AREA:
v It is the Contractor's responsibility to verify
FOR INFILTRATOR TRENCH: DECREASE AREA BY A FACTOR OF 0.50 l y locations of utilities that may affect location of
�.� facilities drawn. Verification is to be made with the
8. FOR USE OF TRENCH TYPE SYSTEM: Owner and the affected utility company.
J � • ��
A 556.62 * 0.5 11. Substitution of materials (i. e. pipe, tanks, etc.) is
= = 278.31 SQ. FT. acceptable provided verification and acceptance by the
Engineer and the Environmental Health Officer is made.
1 S. F.IX = 92.77 L.F.
S STAL 96 L.F. OF INFILTRATOR TRENCH (18 UNITS TOTAL) 12. The location and elevation of the house is schematic.
(, FECTI AREA = 288 S.F. It is paramount that verification of sewer line location
and elevation be checked with building plans prior to
construction.
,/ jpI �'� .i, X
�' Wa �13. Site map supplied by Architect. O
BY
--' 11V1>1 VID UAL S&VA UL
DISPOSAL SYSTEM