HomeMy WebLinkAbout3577 Hwy 6 - 211305201002INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway - Eagle, Colorado 81631 Telephone: 328-8755 ep &?&� YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. Please call for final inspection before covering any portion of installed system. PERMIT NO. 1426 OWNER: Rocky Mountsin Concrete Pumping PHONE: MAILING ADDRESS: PO BOX 890 Gypsum City: Gypsum State: CO ZIP: 81637 APPLICANT: Phillip Purdy /Steve Whitehead PHONE: 471-1934 471-1144 SYSTEM LOCATION: 3577 HWy 6 & 24 TAX PARCEL NUMBER: ./ L, , I I A,._ ' LICENSED INSTALLER: NO: DESIGN ENGINEER OF SYSTEM: INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 1000 GALLON SEPTIC TANK ABSORPTION AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 656 SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: Install 656 SF of absorption trenches. Install inspection ports at the. end Of each trench. Install system via engineered design and call your engineer prior to backfill I ENVIRONMENTAL HEALTH APPROVAL: Y, CONDITIONS: DATE: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25- 10- 104. 1973. AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 656 SQUARE FEET. INSTALLED SEPTIC TANK: 1000 GALLON NA DEGREES NA FEETFROM See Site plan SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY X_ YES —NO COMPLIANCE WITH COUNTY/STATE REQUIREMENTS: X YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. COMMENTS: Engineer certification rPf-PlVPf1 19- ENVIRONMENTAL HEALTH APP ENVIRONMENTAL HEALTH APP APPLICANT / AGENT: HERMIT FEE PERCOLATION TEST FEE (RE-IN.SPECTION IF NqCE RETAIN WITH RECEIPT RECORDS 0 WNER: -�r RECEIPT # CHECK# DATE:D mb 29 , 19.0 Incomplete Applications Will NOT Be Accepted (Site Plan MUST be attached) ISDS Permit # 9 HN Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (Basalt) ************************************************************************** * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: �1004 * (',A®yN+f"" N Co Nc�Lwk ea MAILING ADDRESS: i 0, 1,60X 6q 0 eve 5 U' .A 37 APPLICANT/CO 'ACT PERSON: ?k, <-1,jp LIC N E S EMS CONTRACTOR: COMPANY/DBA: ************ PHONE: 471-tq 34 PHONE: 9j,,7 -8�z i.� . ADDRESS: 4?A Rai �l� �► ��l fYIG to�'�� PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: brad 49'ec S54016 ''Legal -Description: L WT I 1 �6�-` i` (. b/ ru E ~ a Y�. fit/! t1�✓ Tax Parcel Number: '� Z 1, �b S D 1 �d Z Lot Size: a, 3(ok Iq'c► .�:5 Physical Address: 1511 Av.�y �o � 24� ? 1)6&5�eii0 BUILDING TYPE: (Check applicable category) ( ) Residential/Single Family ( ) Residential/Multi-Family* (1_r Commercial/Industrial* TYPE OF WATER SUPPLY: (Check applicable category) ( Well ( ) Spring ( ) Surface ( ) Public Name.of Supplier: Number of Bedrooms Number of Bedrooms Type bC6-t,.0_ /S°roavty 4 eO *These systems require design by a Registered Professional Engineer SIGNATURE: 14 ******************************* Date: ******************************** ********* AMOUNT PAID: RECEIPT DATE: CHECK #:tS� CASHIER Community Development Department (970)328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO December 29, 1995 Rocky Mountain Concrete Pumping P.O. Box 890 Gypsum, CO 81637 Attn: Phillip Purdy Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 8 1631-0179 RE: Final of ISDS Permit No. 1426-95 Parcel #2113-052-01-002. Property location: 3577 HWY 6&24, Dotsero, CO. Dear Mr. Purdy, This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL: Information Brochure Final ISDS Permit cc: files Community Development Department (970)328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO December 12, 1995 Dear Applicant, Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 The Environmental Health Division would like to notify you to make a formal request to extend your Individual Sewage Disposal System(ISDS) Permit 00-'E-ql into the 1996 construction year. The Environmental Health Division discontinued percolation tests on November 15, 1995 and final inspections on December 2, 1995 due to climatic conditions. ISDS permits are active for 120 days after the date of issue if no Building Permit has been issued for the same property. If a Building Permit has been issued for the same property the ISDS will expire at the same time as the building permit. If you still plan to apply for a Building Permit this year or in the early months of 1996 you will need to have a percolation test conducted before your Building Permit will be released. You will have to contact a Registered Professional Engineering(RPE) firm to conduct your percolation test. If you have had your permit issued and have not had your final inspection completed, but plan on constructing the system in the next few weeks, please give our office a call and we will evaluate your permit on a case by case situation. Please give the Environmental Health office a call at 328-8755, if you have any questions regarding your permit extension process. cc: ISDS Permit #/�!)G.-`Iq File 0 rA Inter Mountain Engineering Ltd. December 18, 1995 Rocky Mountain Concrete Pumping Post Office Box 890 Gypsum, Colorado 81637 Attention: Mr. Phil Purdy Subject: Inspection of Septic System Lot 1, Neumayer-Brown Re -Subdivision Eagle County, Colorado Project No. 94739G Dear Mr. Purdy: - Mr. - Jim Gabriel.visited the project site on November_16, 1995 to .inspect the installation of the septic system. The septic system was installed in substantial compliance with the septic system plans and specifications as. prepared by Inter -Mountain Engineering LTD for Lot 1, Neumayer-Brown Re -Subdivision, dated December 15, 1994. Should you have any questions regarding the information contained in this letter, please contact the undersigned. E. Geotechnical Engineer ROR:lat cc: Eagle County Environmental Health Department 77 Metcalf Road, #201 • Box 978 • Avon, Colorado 81620 • Phone: 970-949-5072 • From Denver Direct: 893-1531 1420 Vance Street • Lakewood, Colorado 80215 • Phone: 303-232-0158 MEMORANDUM DATE: 5/19/95 TO: PAUL CLARKSON FROM: JEFF FEDRIZZI RE: ROCKY MOUNTAIN CONCRETE PUMPING(ISDS PERMIT #1426-94) Environmental Health has reviewed Rocky Mountain Concrete Pumping's Special Use Permit Application: 1. Intermountain Engineering, Inc. designed and submitted an ISDS. Review of the proposed ISDS meets with Eagle County Land Use Regulations, Chapter IV. Upon further notice from the Planning Division issuance of ISDS Permit #1426-94 will occur. 2. There are no other environmental health concerns that are evident after reviewing the Special Use Permit application. 1426-94 ROCKY MTN CONCRETE PLUMB JOB NA_' 3577 Hwy 6 & 24 Lot l Neumayer,-,.Brown Re —subdivision i 706 LOCATION BILL TO DATE STARTED DATE COMPLETED DATE. BILLED WOO ! L \ qL 0( t/f�11 �rLi 1� 1 h JOB COST SUMMARY TOTAL SELLING PRICE O _ / TOTAL MATERIAL TOTAL LABOR _ L INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT 00/ JOB FOLDER Product 278 ®® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB FOLDER .It Printed in U.S.A W } n- z � W 51 W U a C) COP W $a. O 0 r GRAPHIC SCALE 0 ±5 30 60 ( IN FEET ) 1 inch = 30 ft. BARB WRE FENCE C FENCE - INSTALL CLEANOUT BETWEEN J� l H` USE AND SEP ,n, C TANK \ 4- SOLID PVC FPE 0 1/4' PER FOOT SLOPE (MA)0 1000 GA L CN" TWO CCWAR T M£ti T LEGEND s£PT TZ K - S££ DETAIL E -1STiVG 6Rr1ii1VD COV T1UR ("2 ) EXISTING GROUND CONTOUR (' � - -�� PROP. GROUND COAITOUR 21 IN_ TALL-If-ANOUT. AT PROP. GROUND CONTOUR (10 ) (�) N F /`, TT L D node %ate �� POWE4 POLE -fJ GUY i'Y",4E ❑ ❑ — MESH FENL'E \ X X— BARB WRE FENCE BAPS WIRE FENCE OE D VE-RHEAD EL ECTR'C L lhf- EXISTING (;RA VEL CONC SLAB 53 4 RL;r. SPOT ELEV(0153 4) J /N5TALL SPLASH FLAT£ AT' INLET CHAMBER (TYP) i EDGE OF GRAVEL ROAD w !J S. i STANDARD INFILTRATOR CHAMBER (3'x 6 %4'x I EDGE OF GRAVEL ROAD EXIST 18' CALF CULVERT '-MATCH EXIST. ` GRAVEL ROAD (MAN) VARIOUS DEP TH _ 2' (MAX) SERIAL DISTRIBUTION NO SCALE 1000 Gal. Two Compartment Septic Tank PLAN u ; U 21" clear insert access SECTION a 6" 3" A B 55" 52" Dimensions Capacities Iv+�1oo•1 A B Approximate Weights W L H Tank Lid Baffle Walls Total 5'-5' 8'-5' 5'-10' 675 325 5470 lbs 3000 ibs 12 9,720 NO TES: 1. Sewer line from building to septic tank shall have a maximum slope of 1/4" per foot. Bends in building sewer shall be limited to 45 degrees. 2 Septic tank shall be installed level. Tank to have removable cover or manholes to within 8 inches of finish grade for access to each comportment, for cleaning and inspection. Septic tank to meet all the requirements of Eagle County individual Sewage Disposal Systems, Section 4 07 J. Excavate and level J feet wide trenches, 2.5 feet deep and 6 feet apart. 4 Prepare trench bottom and sides in accordance with the state and local regulations. (For the Infiltrator System, raking sidewoll and bottom infiltrative surfaces is recommended to reduce smearing.) 5. Assemble and install the Infiltrator Chambers in the Trenches according to the manufacturers recommendations. 6. Bockfill the side wail area with native soil for proper support_ 7. Backfill the trenches with a minimum of 12 inches of tamped "sail cover. 8. Avoid vehicle traffic over the system. 9 All installations shall meet the rules and regulctions of Eog/e County Environmental Health Division as set forth /n the Individual Sewage Disposal System regulations. Construction of the system shall be inspected by the Engineer, prior to bockt7lling. 10 If during the construction of the /eachfe/d, solid or fragmented bedrock is encountered the engineer should be contacted immediately for additional recommendations. DESIGN FLOW Design Percolation Rote, T=,117 mjnute per inch Number of Employees = 10 L- - Maximum Doily Flow = Qm Qmax = 15 employees x 5 ;g0l, ns/person/day x 15OX Qmox = 7875 gallons pe SEP TIC TANK 1r = Qmox x 30hrs 24hrs V = 787.5 x JO = 984 gallons - 24 - -- - - Use one 1000 gallon two compartment septic tank. ABSORPTION AREA A = Qmar 5 A = 7875 1-17 - 650 sq. ft 5 Check Area Using Table 7-2 (EPA Design Manual.• Onsite Wastewater Treatment and Disposal Systems) Flow Rate < 12 ' Absorption Area 787 5 qAd = 656.25 sq. ft. 1.2 Use on absorption area of 656 sq. ft. Infiltrator Chamber System in a trench confgurction is recommended, with an allowed 50Z reduction in the required absorption area. 0.5 Amox = .328 sq ft. Surface area of one Infiltrator Chamber = 18.75 sq. ft. Use 18 Infiltrator Chambers. Two trenches with 9 Infiltrators. SUBSURFACE SOIL CONDITIONS Test Pit No. 1 " 0.0 - 0. 2' Topsoil 0.2' - 8.0' Light brown silty sonde GRAVEL w th rock fragments w 70N TEST HOLE (TYP) 1 LE HOLE - y!r 7RT (TYP) ✓�"' v 41L - . - 16 g a ld� 1 � • e HIGHWAY 6 & 24 REVISIONS P O BOX 97O Q77 ROADIKE;2oie }ABM iWi�ii�iii $ia t01 1420 vANc� s,'Ri�r ,uETCALF AWAY, COLO e,620 (JOJ) 9t9-5072 • L ACEWO 7. COLO. 80215 :VgMI. (JOJ) 2J2-0156 PRQ.ECr Na 947J9'' DEVGGVE0 BY. MLM SEPTIC SYSTEM DESIGN VRA MN B r.' FLS MLM LOT 1 DA 1E /SSAn 10106194 CHECXED BY NEUMA YR-BROWV SCALE D RE- SUBDI VISION I - 30 r1£LD NO 295170 EAGLE- COUNTY, COL ORA DO 1 . I