HomeMy WebLinkAbout222 Granada Hill - 210701403005 - 1351-94IS EXPIREDINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway - Eagle, Colorado 81631 Telephone: 328-8755 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1 3 5 I Please call for final inspection before covering any portion of installed system. OWNER: Jerold Wuhrman/ Las Vistas Devel. Inc. PHONE: 926-4567 MAILING ADDRESS: P.O. Box 598 cit, Edwards State: CO Zip: 81632 APPLICANT: Bob Or Ed PHONE: SYSTEM LOCATION: 222 Granada Hall Road TAX PARCEL NUMBER: 2107-014-03-005 LICENSED INSTALLER: Stenson Excavating LICENSENO: 55--94 DESIGN ENGINEER OF SYSTEM: Inter Mountain Engineering -Russel Thrasher INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: The engineer must send Eagle County Env. Health Div. 2000 GALLON SEPTIC TANK a letter verifying system installation design before ABSORPTION AREA REQUIREMENTS: ISDS final letter will be mailed. XXXXX SQUARE FEET OF SEEPAGE BED 1057 SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: Install 56 infiltrator units, (4 trenches with 14 per trench), as per engineer' design. Install inspection portals at the end of each trench The trench bottom elevations must be no deeper than 3' , _ -- _ reC2- -- -, ENVIRONMENTAL HEALTH APPROVA' _ DATE: CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25- 10. 104. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET. INSTALLED SEPTIC TANK: GALLON DEGREES FEET FROM SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY _ YES _ NO COMPLIANCE WITH COUNTY/STATE REQUIREMENTS: YES _ NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. COMMENTS: ENVIRONMENTAL HEALTH APPROVAL: DATE: ENVIRONMENTAL HEALTH APPROVAL: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS APPLICANT / AGENT: OWNER: PERMIT FEE PERCOLATION TEST FEE RECEIPT# CHECK# In;omplete Applications Will NOT Be Accepted (Site Plan MUST be attached) ISDS Permit. # Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE.- EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (Basalt) * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * MAKE ALL REMITTANCE PAYABLE'w�0: "EAGLE COUNTY TREASURER" PROPERTY OWNER*. MAILING ADDRESS: -S-V'k C� O $��3Z PHONE: QLZ(o LkS 671 APPLICANT/CONTACT PERSON: 0`0 PHONE: rr LICENSED SYSTEMS CONTRACTOR: `� �+v_ LAfll SD Ll EC; PHONE COMPANY/DBA: ADDRESS: PERMIT APPLICATION IS FOR: �Pq NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: LrA- -�d F- 3 Tax Parcel Number: 2\ O --7 a t H — b3 I COTLot Size: '2 , 214cf�' Physical Address: BUILDING TYPE:. (Check applicable category) Residential/Single Family ( ) Residential/Multi-Family* ( ) Commercial/Industrial* TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surface Public Name of Supplier: Number Number Type _ of Bedrooms S of Bedrooms *These systems require design by a Registered Professional Engineer SIGNATURE: Date: LA ************* AMOUNT PAID: *****************************************)**************** c7C�'C�Zj RECEIPT #: 1Z C7g DATE:�12���� CHECK #: jgg4 CASHIER: COMMUNITY DEVELOPMENT DEPARTMENT (303)328-8730 EAGLE COUNTY, COLORADO December 2, 1994 Jerold Wuhrman P.O. Box 598 Edwards, CO 81632 Dear Applicant, 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX: (303) 328-7185 The Environmental Health Division would like to notify you to make a formal request to extend your Individual Sewage Disposal System(ISDS) Permit #1351-94 into the 1995 construction year. The Environmental Health Division discontinued percolation tests on November 15, 1994 and final inspections on December 21 1994 due to climatic conditions. ISDS permits are active for 120 days after the date of issue if no Building Permit has been issued for the same property. If a Building Permit has been issued for the same property the ISDS will expire at the same time as the building permit. If you :;till plan to apply for a Building Permit this year or in the early months of 1995 you will need to have a percolation test conducted before your Building Permit will be released. You will have to contact a Registered Professional Engineering(RPE) firm to conduct your percolation test. If you have had your permit issued and have not had your final inspection completed, but plan on constructing the system in the next few weeks, please give our office a call and we will evaluate your permit on a case by case situation. Please give the Environmental Health office a call at 328-8755, if you have any questions regarding your permit extension process. cc: ISDS Permit #1351-94 File COMMUNITY DEVLOPMENT DEPARTMENT (303)328-8730 EAGLE COUNTY, COLORADO DATE•May 5 1994 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX: (303) 328-7185 Jerold Wuhrmam/Las Vistas Development Tax Parcel #2107-014-03-005 222 Granada Hill Rd., Edwards Dear I.S.D.S. Applicant: Your application for an Individual Sewage Disposal System (ISDS) Permit for #1351-94 has been received. Issuance of your permit is on hold until the following materials or fee(s) are submitted. Site Plan X Licensed System Contractor (See attached list) X Engineer Design - this is a requirement as per the final plat. X �Other:a refund for 200.00 for the percolation test will be �4� forthcoming. 1� Please keep in mind that an incomplete ISDS permit application will result in delaying issuance of any corresponding building permits. If you have any questions please contact Tania Busch -Weak at, 328-8755. When calling or submitting information please reference your ISDS application #1332-94. Please submit information to: Eagle County Environmental Health Division P.O. Box 179 500 Broadway Eagle, CO 81631 JCJJ 74771)J7 1 N I CK-I'IUUN 1 H I N tNU. 347 P02 AUG 01 '94 15:41 i I SOT4S AND FOUNDATION INVESTIGATION FOR PROPOSED RESIDENCE LOT 80, CORDILLERA EAGLE COUNTY, COLORADO PREPARED FOR: JERRY WUHRMAN PROJECT NO. 93383G JULY 1993 i. I �'N I iLJ,-Jw i n lit civa. S4'r r03 HUU 01 ' 94 15: 41 i QQ Y under full pressu.r*, does not fall within five feet of foundation walls, porches or pjatio slabs. Lawn irrigation must be controlled. If the future !owners desire to plant next to foundation walls, porches or patio !slabs, and are walling to assume the risk of structural damage,: etc., then it is advisable to plant only flowers and shrubbery (n6 lawn) of varieties that require very little moisture. These flowers and shrubs should be hand watered only. gi788iIiRF Cg BVAgM I DTAMAL YSTLM Test pit No. 1 was dug in the leach field area. The soil profile of Test: ,Pit Na. 1 consisted of 1.5 feet of topsoil, underlain by dark -gray shale. The percolation test holes were also dug in the proposied leach field area to the south of Test Pit NO. 1; however the Boils encountered in the percolation test pits consisted of gypsum in Percolation Test Pit No. 1 and light brown, sandy silt in P#rcolation Test Pit Nos. 2 and 3. It ac ail possible, it is ziecommended to keep the leach field area away from the gypsum. The percolation test results were as follows: Pere Test H • 1. Rerc Tee No. 2 Pere Teat—yQ. 3 28.8 min/itich 22.1 min/inch 18.8 ''min/inch The average percolation rate is 23.2 mien/inch. MI_13CBLL EOUS The recommet1dations provided herein are based on experience in the area and froth the on -site field exploration. The information 34 r t U4 HUU 01 'J4 15:42 ( Lot 76 ' i ti I Lot 26 FORTH Lot 80 Pere Hole #1 Pere Hole #208 !reSt Pit #1 Pere Hole ##30 Lot 79 � 1 Purple Stak r1 Proposed+ 6 Resident 'I-P-rot�OUL Drive r � t r Testilit #2 r � TEST LOCATIONS ARE RELATIVE GRANADA `� e TO THE EXISTING PURPLE STAKE HIr,I Lot 27 TEST' LOCATION � Proposed Residence Lot 80, Cordillera Eagle County, Colorado Prepared for Jerry Wuhrman 'Rowe Hal. 93383G DRAWN RY+ SCALE+ 1" 1--80' DAM 7 /$/93 CAAWING NO, 1 VS, TOgnu god Lt72 'WWTHiwnnw-NqIWT 1351-94 - Parcel #2107-014-03-005 JOB NAME _ 222 Granada Hill Rd. WUH?YAN lot 80 Cordillera LAS VISTAS DEVE. JOB NO. JOB LOCATION 1 BILL TO DATE STAR D r64LETED DATE BILLED NL 1�� d o-cJ . Not 155 e ukihl Ra, Aes rc vie (,)E a-v �.Q - -2 10 - C)1 - 6 3-Coll - _� % -�- C'I t(.r l/u'R wit /d i� �`�� 8l '✓ O r �� I TI / t �:- �r�� �Ot- � Its 4M1.c/vv� ! j / r, i �•-- .f Gf , • l/// _; , r _ - r j l C] fD 7 tl �t�/✓ �� i YJv E rvr (W M �,/"C�✓M1-- � LEA �r"V`^�` 5 � f�i j±Jt�/ f� a �• ty pv_*n .C1�" lz'e, f "" `CL JOB FOLDER Product 278 � © NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB FOLDER j