HomeMy WebLinkAbout781 Lake Creek Rd - 210507101001 - 1058-91ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 10 5`0 Please call for final inspection before covering any portion of installed system. Thomas & Judith Pyle 608-275-4590 OWNER: PHONE: MAILING ADDRESS: 601 Ray-o-Vac Drive, Madison, WI AGENT: PHONE: SYSTEM LOCATION: 781 Lake Creek Road, Edwards, CO LICENSED INSTALLER: Jack R. Sills LICENSE NO. 21-91 DESIGN ENGINEER OF SYSTEM' Alpine Engineering, Inc. INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: 2500 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT. DISPERSAL AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: Install as per engineer design with 40 infiltrator units ENVIRONMENTAL HEALTH OFFICER: DATE: CONDITIONS: 1. ALL INSTAIIAT11AV.11STCOMPLY WITH ALL RE_ EN F THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, C.R.S. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED' PRIOR TO COVERING ANY PORTION OF THE SYSTEM. r� 1LI INSTALLED ABSORPTION OR DISPERSAL AREA: /1224 SQUARE FEET. D� 1,7T;111l aYs INSTALLED SEPTIC TANK: 2'J O�*O GALLONS 37 DEGREES 71 FEET In- w Crtnewl efj 9c- r, SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR: \V PROPER MATERIALS ANDASSEMBLY YES NO COMPLIANCE WITH COUNTYISTATE REGULATION REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: ENVIRONMENTAL HEALTH OFFICER: DATE: ENVIRONMENTAL HEALTH OFFICER: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS PERMIT APPLICANTIAGENT: AMOUNT PAID: RECEIPT N: CHECK k: CASHIER: ISDS Permit # Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE- EAGLE COUNTY P.O. BOX 179 EAGLE, CO 81631 328-8730/927-3823(Basalt) PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $125.00 PROPERTY OWNER: MAILING ADDRESS: ®/ /24y � - 11Ac-- 1 60-e, AI Ik OU AN PHONE: 6VV 2 23- 4!7-?f0 APPLICANT/CONTACT PERSON: _ 41e13oa.,� 1Z-e e 60 PHONE: 3-�)3/9�l f - 5 15 z LICENSED SYSTEMS CONTRACTOR: ADDRESS: 45�c 705-p, s PERMIT APPLICATION IS FOR: W LOCATION OF PROPOSED INDIVIDUAL Legal Description: A/E Parcel Number: Physical Address: il7G�yc� ��2,1 �i5 PHONE: 8%6 " .5 Ya I NEW INSTALLATION ( ) ALTERATION ( ) REPAIR SEWAGE'DISPOSAL SYSTEM: t size: Co BUILDING TYPE: - -- (Check applicable category) (B-I Residential / Single Family Number of Bedrooms 7 (-)--Residential ./ Multi -Family* Number of Bedrooms ( ) Commercial / Industrial* Type HOT TUB Yes ( ). No WATER CONSERVATION PLAN: Yes ( ) No ( ) TYPE OF WATER SUPPLY: Well " -Spring ( ) Surface (-) Public ( ) Name of Supplier: Give depth of all wells within 200 feet of system: *These systems require design by a Registered Professional Engineer NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" SIGNATURE: DATE: I/ AMOUNT -PAID: / RECEIPT# 6�� 2 CHECK # TIME LOG Y// Travel Perc Final / 1 Ar DATE:'IV - 5 CASHIER: S-ti vt c � a rya ry '# ' 300 BROADWAY COMMUNITY DEVELOPMENT DEPARTMENT _ y P.O. BOX 179 EAGLE. COLORADO 81631 (303) 328-8730 FAX (303) 328.7207 EAGLE CQEN, C0ORAD r � f August 26, 1991 Mr.,. and. Judith Pyle 60.1.Ray-o-Vac: Drive Madison, WI 63419 RE: Final of: ISDS Permit No. 1058 Dear Mr. and Mrs. Pyle: This letter is to inform you that the above. referenced ISDS Permit has been inspected and.finalized.:'Enclosed.is a copy to retain for your records. Also enclosed are informationalsheets regarding the care of your septic system. If you have any questions regarding this. permit, please contact the Eagle County Environmental Health Division, P.O. Box 179, Eagle,. Colorado 81631. We can also-be:reached, depending on your. calling area,, at the following numbers:. Eagle Valley 328-8730.E Basalt/E.l. Jebel 927-3823:.. Sincerely',. s X C'.- Kelley Carhart uu office Assistant z rf u n ckc: `Encl:. Informational Sheets k Final ISDS: Permit cc: Chrono File Building Permit File k f It.�kN f q , �* 725 CHAMBERS AVE. P.O. BOX 173 MMUNITY DEVELOPMENT EAGLE. CO LORADO 8 t ., ... "'DEPARTMENT FAX (303) 3284207 (303) 328.8730 x, LODO li EAGLECaga i� w fi 46, , July 22, 1991 Mrs. Thomas Pyle Mr, and 601 Ray-o-Vac Drive "Madison, WI 63419 Individual Sewage Disposal System Permit RE: issuance of No. 1058 Dear Mr.. and Mrs. Pyle: caIsed copy Of ] ISDS Permit No..1058• hSitecloYou Enclosed is your must be at the installationportion of permit must posted f ore linspectng any is final inspeceadl neon ons our office for for final the d the installed system; December 1. have any questions, please feel free to contact us at Eagle Vall If you ea: following numbers depending on your calling 328-8730; Basalt/El Jebel 927 -3823, ext ' Sincere P. Merry, R.E. . :.. ` Raymo Environmental Health fficer community Developmen 'k RPM : ckc Enclosure cc: ISDS File J ALPINE ENGINEERING INC July 17, 1991 Mr. Ray Merry Environmental Health Office P.O. Box 179 Eagle, CO 81631 RE: Pyle Ranch Septic System Dear Mr. Merry, Enclosed please find the application for an Individual Sewage Disposal System Permit with attached plans for your review. The following is an overview of the project with criteria and design calculations. INTRODUCTION The project site is located in Lot 1, Block 4, of the Homestead Filing No. 1 in Eagle County, Colorado. The site is bounded on the east by Lake Creek Road, on the west by Lake Creek and on the north and south by existing residences. The proposed service is for a single family residential unit with 5 bedrooms and a detached garage which will house a caretaker's unit above. The caretaker's unit will have 2 future bedrooms. Water service will be supplied by a well. The existing ground slopes gently to the north averaging 3 percent. PERCOLATION TEST/SOIL PROFILE On July 9, 1991, three percolation test holes were dug in the proposed Edwards Business Center • P.O. Box 97 • Edwards, Colorado 81632.303/926-3373 • FAX 303/926-3390 s leach field area. Test hole locations are shown on the attached plan. The percolation test holes were dug and tested in accordance with Eagle County guidelines and standards. Alpine Engineering, Inc. monitored and recorded the test results and are as follows: HOLE PERCOLATION RATE MIN/INCH No. 1 12 No. 2 27 No. 3 7 Ave = 15 min/inch A soil profile hole was dug in close proximity to the proposed leach field to a depth of 8-feet. The soil appeared to have a medium to dark brown clay layer for the first 2-feet with well -graded sands and gravels to a depth of 6- feet. The lower 2-feet of the soil profile hole consisted of well -graded gravel to cobbles. The soil profile hole was monitored for approximately 10-days prior to performing the percolation tests. No groundwater was ever observed in the profile hole. Bedrock was not encountered. If you should have any questions, please call. Sincerely, Jmes McNeil, PE JM /1m Enclosure D,f5161AI GQl F&-r-161 �At c-uL rlo�i5. � F3 �O�vov15 -t- 2 Flit T�f2E _ � 7`a ri9 L Q - Qoo,vts X 2 �ieY�om X X �SO�a 2, . 1e57,991` 70 1� 2 ER / - A4eA7-29 ,¢= rszo AZ y .. �,CS�� vc/nre � p✓ovr��c'S �or G�- �D�v l�G�/✓(G�`�'4Li Xto �� �I �-opsn 5 � Z ✓�U G% " ' �/����✓Dols-� o D�Tcwirio�/ TiMg- UOC . d P7 ALPINE ENGINEERING INC L XTTSR OF TRMSMrffAL Edwards Business Center a P.O. Box 97 e Edwards. Colorado 81632 e 303/926-3373 Fax 303/926-3309 N 0 - Mo SIVA M, Gentlemen, We an sending you the following Items: >(altached ❑ under separate covet via ❑ shop drawings ❑ reproductions Cl originals ❑ copy of letter ❑ change order ❑ samPles These are transmitted ❑ for approval EAGLE COUNTY ❑ w your u3e COMMUNITY DEVELOPME%after ban to us cam to ❑ speci0cations ❑ as requested ❑ reviewed ❑ ❑ for review and comment ❑ for your record JOB NAME. LVI., - (� ) Joe Nq-"Lo --- •---•-•• •���. �• `,:,:�Ig ���.,........ w.�u.cw ocnni,c, nvv., UnUIUN, MA 01471 JOB FOLDER Printed in U.S.A P A IF ti Z'4 C"/ P/ I PYLE RANCH r SEPTICSYSTEM t INSTALL RISER SECTIONS TO WITHIN 6" OF FINISH NDS, DIVERTER VALVE 4" OBSERVATION PORTAL GRADE (IF NEC.) EXISTING GRADE (TYP) INFILTRATOR UNITS -10O ' -99 - +98 BACKFILL I 2500 GALLON SEPTIC TANK . S = I% —� s '(BOTTOM INV. IN = 96J0 V IN . OUT 95. OF -TRENCH 85 = 95.85 n LF PLACE G" OF 3 /4% 11 /2" SCREENED ROCK UNDER SEPTIC - GUEST TANK AND PVC SAN. SEWER LINE HOUSE ALL BACKFILL MATERIAL TO BE COMPACTED TO 85V. AASHTO T-99 SEPTIC SYSTEM PROFILE i NTS TREELINE (TYPICAL) - C k / EXISTING FENCE _ TO REMAIN (TYP.) t/ EXISTING GRAVEL DRIVE (TYP.) � I 6296 40 PERC HOLE /� o �Igo� J n (TYP.) ra IRRIGA�IOBADK CH 13 �_. I • /• SF #2 _ / PROVIDE SWALE ALONG PROPOSEDDRIVEWAY DIRECT IRRIGATION f AND RUNOFFO AWAY FROM LEACH FILD SOIL PROFILE / HOLE 0 / M . �� -EXISTING 24" C P `' #3 7300 ' \� PROPOSED-? /•'� 2r AN pILT.J 1 �\ O INSTALL 4" ACCESS PORT VC 3 �° 9 END OF INFILTRATION I / " '► 75 LF 1 1% NDS DIVERTER VALVE UNIT (TYP.) - EXTEND 24" ABOVE FINISH GRADE i jE7,,STING OR EQUAL / 6` aEANOW ' I 45 HORZ. BEND WV. = 96.85 / 2500 GAL. SEPTIC TANK RIM EL. = 7300.5# / ` I j / / WV. IN - 96JO PROPOS-EfJURIVE NAY WV. OUT = 95.85 P OPOSED I I f W LL SITE PASTURE co I IN,Q INFILTRATOR UNIT (TYP) INSTALL IN ACCORDANCE W/ I � ' ` / MANUFACTURER'S SPECIFICATIONS r / � I RESIDENCE i FLOWLINE OF RELOCATED IRRIGATION DITCH 4" PVC FLOWLINE OF IRRIGATION DITCH PRIOR TO RELOCATION 3-WAY NDS DIVERTER VALVE OR EQUAL / VALVE STEM TO EXTEND TO GRADE Ioli / I LEACH FIELD DETAIL SCALE.•"= 20' 15011 OF TRENCH) t• INFILTRATOR UNITS TO BE PLACED ON BOTTOM OF TRENCH 40 UNITS TOTAL I I i ` 11