HomeMy WebLinkAbout2331 Squaw Creek Rd - 210711100058 - 1077-91ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERM IT. NO. 1077 Please call for final inspection before covering any portion of installed system. OWNER: Nathan Flnk$e e+ PHONE: 874-9900 MAILING ADDRESS: P.O. Box 1581 Avon, CO 81620 AGENT: PHONE: SYSTEM LOCATION: 2331 Squaw Creek Road LICENSED INSTALLER: Steve // Ruder ��LICENSE NO. 29-91 DESIGN ENGINEER OF SYSTEM:- J_gX.,,xso, `� kw,,, ke-J INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: GALLON SEPTIC TANK OR 1000 GALLON AERATED TREATMENT UNIT. DISPERSAL AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 756 SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: V 25 infiltrator units as per design ENVIRONMENTAL HEALTH OFFICER: DATE: v 1 CONDITIONS: 1. ALL INSTALLATION ST COMPLY WITH ALL REQUIREM NTS E EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25.10-104, C.R.S. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED' PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 756 SQUARE FEET. by25 IT►fil�raibr UI'1i45 INSTALLEDSEPTICTANK: IPZ50 GALLONS ✓U DEGREES 65-FEET.incties from S.e. Corner Of A41b SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR: PROPER MATERIALS AND ASSEMBLY N YES NO COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: NOT INTENDED FOR USE DURING SPECIAL EVENTS ENVIRONMENTAL HEALTH OFFICER: DATE: __v_ ENVIRONMENTAL HEALTH OFFICER: (RE -INSPECTION IF NECESSARY) DATE: RETAIN WITH RECEIPT RECORDS PERMIT APPLICANT/AGENT: OWNER: AMOUNT PAID: RECEIPT #: CHECK #: CASHIER: ISDS Permit # 0 J Building Permit # ITA_ - APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE- EAGLE COUNTY P.O. BOX 179 EAGLE, CO 81631 328- PERMIT APPLICATION FEE $/ $150.00 PROPERTY OWNER: f`t �Q MAILING ADDRESS: APPLICANT/CONTACT PERSON: LICENSED SYSTEMS CONTRACTOR:_ 27-3823(Basalt) PERCOLATION TEST FEE PHONE: 1z _ rP66 �0 C PHONE: _ �77 ADDRESS: PHONE: PERMIT APPLICATION IS FOR: ( NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: Parcel Number: Lot size: Physical Address: BUILDING TYPE: - -- (Check applicable ca(tegory) ( ) Residential / Single Family Number of Bedrooms ( ) Residential ./ Multi -Family* Numb3No Bedrooms ( ) Commercial / Industrial*. Type /L� HOT TUB Yes ( )- WATER CONSERVATION PLAN: Yes ( ) TYPE OF WATER SUPPLY: Well(X1 .Spring ( ) Surface ( •) Public ( ) Name of Supplier: Give depth of all wells within 200 feet of system: *These systems require design by a Registered Professional Engineer NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION MAKE ALL REMITTANCE PA E TO- "EAGLE COUNTY TREASURER" SIGNATURE: DATE: do AMOUNT PAID: �j�j .00RECEIPTDATE: CHECK # CASHIER: TIME LOG Travel Perc Final ,AM EAGLE COUNTY., WLORADa RE: Issuance of Individual -Sewage Disposal System Permit No. 1077 Dear Mr. Finkle: COMMUNITY DEVELOPMENT DEPARTMENT (303) 328-8730 EAGLE COUNTY, COLORADO September 3, 1991 Mr. Nathan Finkle P.O. Box 1581 Avon, CO 81620 RE: Final of ISDS Permit No. 1077 Dear Mr. Finkle: 500 BROADWAY P.O. BOX 179 EAGLE. COLORADO 81631 FAX (303) 328.7207 This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to _retain for your records. Also enclosed are informational sheets regarding the care of your septic system. - If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division, P.O. Box 179, Eagle, Colorado 81631. We can also be reached, depending on your calling area, at the following numbers: Eagle valley 328-8730; Basalt/El Jebel 927-3823. Sincerely, C. Kelley Carhart Office Assistant ckc Encl: Informational sheets Final ISDS Permit cc: Chrono File ISDS File Building Permit File Al/ /' w RECEIVE® S. Ruder Excavating Company P.O.Box R Edwards, Colorado 81632 Ruby Ridge Ranch Company Mr. Nathan Finkel P.O.Box 1581 Avon, Colorado 81620 Dear Nathan, As per our phone conversation last night, I have gone over the as-builts for the sewer system I installed at your facility. I recall you requesting me to install the best system possible and to incorporate the latest and most technically advanced materials possible. Nathan, this request was fulfilled and therefore, I feel that the large 1200 gallon (two compartment) tank and the double run infiltrator leaching system over screened rock,. .gives you far in excess the present needs you now have and it should also easily handle most future add-ons. Please find enclosed, the complete as-builts and information on the leaching material used. All materials were purchased from Kemp & Company, along with his personal input and recomendations. This letter should stand as a conformation of the excellent sewer system you now have. I will also be glad to meet with you or talk to anyone at the county. Icer , L.S.Ruder ,V COMMUNITY DEVELOPMENT DEPARTMENT (303) 328-8730 EAGLE COUNTY, COLORADO January 25, 1993 Mr. Nathan Finkel Ruby Ridge Ranch P.O. Box 1581 Avon, CO 81620 Dear Mr. Finkel, 300 BROADWAY P.O. BOX 1 7 a EAGLE. COLORADO S 1631 FAX (303) 31S.71-07 I'm writing in regard to your building permit applications which you submitted for permission to hook up a mobile home, (#5425), and to construct an apartment above your equestrian facility, (#5596). These permits been brought to my attention as part of the building permit routing process to evaluate the adequacy of the individual sewage disposal system (ISDS #1077) which exists on site. I feel a brief history would help explain the dilemma with which we are currently faced. The original design of the system was engineered by Chris Williams, Johnson, Kunkel & Associates, Inc. The system design assumed estimated wastewater flows of 488 gallons per day. This flow was determined by the number of fixtures in the equestrian facility, the number of employees expected to use these fixtures, then adding the flow from the proposed apartment. The existing system was sized and installed according to these specifications with the final inspection performed on August 30, 1991. On July 24, 1992, you submitted building permit application, #5425, for a mobile home hook up. It was communicated to you in a letter from Roger Boyd of my staff dated August 5, 1992, that the existing system was not appropriately sized for the addition of a three bedroom mobile home. The building permit application was placed on hold, but the mobile home was hooked up and connected to the septic system without permission. A description of the system, including the mobile home connection was described to you in a letter from L.S. Ruder, S. Ruder Excavating Company, a copy of which was received by our office on December 2, 1992. Failure to obtain a permit for this connection constitutes a violation of the Eagle County Land Use Regulations, Chapter 4, Section 4.03.29. Mr. Nathan Finkel January 25, 1993 Page 2 Furthermore, in Mr. Ruder's letter, he describes the system which he installed as a 1200 gallon septic tank with a double run of infiltrator leaching system over screened rock. The Infiltrator technology is a chambered system which is granted a reduction in size due to the absence of rock. Placing the chambers on rock defeats the purpose for which a reduction in size is granted, therefore, the system is technically undersized for the use which currently exists. On December 3, 1992, an application was submitted, #5596, to construct the apartment in the equestrian building. Based on the above information, we are not inclined to grant approval for the construction of this dwelling unit without necessary corrections made to the septic system. Due to the limited area for septic improvements, it is unlikely that the septic system can be brought into compliance with Eagle County Regulations. It is my understanding that it is your desire to connect to the sewer line which is being extended to serve the western parcel of Cordillera's Planned Unit Development. Since there is currently no evidence that your existing septic system has failed, we will allow the continued use of the system until the public sewer line is available. Should the system fail prior to the availability of the sewer line, appropriate actions must be taken to resolve the failure. Another option is to remove the mobile home in order to allow for the construction of the caretaker unit. The septic system cannot accommodate the effluent from both units. Once the sewer line is available, you as originally proposed. If you have decision, don't hesitate calling. Sincerely_, / Raymond Merry, REHS Enviro ental Health ger may proceed with your plans any questions regarding this cc: Keith Montag, Director of Community Development Gerald Best, Chief Building Official L.S. Ruder, S. Ruder Excavating, Inc. ISDS File #1077 BP Files #5425 & #5596 `ls lJui / � tape r•��0� I -17 If 1110? a T,9 N of ;�ON: /�iJOy 47&; / r Ir;�fe RAC c/ l jAA Seco.� � C%An a bT 6� � �iee ••r is L/�,gnev fs LA Ed vE � �'�� y�oty rk- tfd� 7�� K MEMORANDUM TO: Paul Clarkson, Zoning Administrator FROM: Raymond P. Merr S, Env. Health Div. DATE: October 6, 199 RE: Ruby Ridge Ranch / Nathan Finkel property Building Permit #5425 On July 24, 1992 the Building Division accepted an application for a mobile home hook up at the Ruby Ridge Ranch. During the routing process, my Division placed a hold on the permit due to the inability of the existing septic system to accommodate additional flows from the three bedroom mobile home proposed (see attached letter from Roger Boyd to Nathan Finkel, dated August 5, 1992). Apparently, the mobile home has been connected to the existing system without permission. This illegal hook-up constitutes a violation of Chapter IV of our Land Use Regulations, Sections 4.03.03; 4.03.07; 4.03.28, 5); as well as 4.03.29, 1). The latter violation constitutes a Class I Petty Offense as defined in Section 18-1-107, C. R. S. 1973, as amended, and carries with it a maximum fine of $500.00 and/or six months in jail. This memorandum is being sent to you via at DRT regarding a consolidated effort to Development concerns through one channel. no zoning infractions exist at this site, I can consider separate action. CC. ISDS File #1077 BP File #5425 the direction received address all Community Should you find that please notify me for so k SaoNNN NNN NNN NNN 000 NOO "c4 i ♦v- ■ LO i i f � to VI) t5' � I Illy-0� � . � 1 .. - w a Z CO 3 � a CA D F _ pt M p ^ S M h 3 - o s k ( x y v mac- v' `— 3 �e�x'raon�ts = Co`75 c3a.Q I Lo 3 cbcxll� 1 La3 ,c 3� ,= 1--q5l (ykL 4&rv, needed aoo J a aeno e sin 2 (^ u n, fk '� oC' i � ► nC3�Q. C� PS i C'� l)Ue reco N1 rq �e- l -For- C (-'r S i s-fa�c) f dCrrit - COMMUNITY DEVELOPMENT DEPARTMENT (303) 32S-8730 EAGLE COUNTY, COLORADO August 5, 1992 Nathan Finkel Ruby Ridge Ranch P.O. Box 1581 Avon, Colorado 81620 Dear Mr. Finkel, 500 BROADWAY P.O- BOX 179 EAGLE, COLORADO S 1631 FAX (303) 325-7207 The Environmental Health Division has reviewed your building permit application and determined that the septic system is not currently sized for the addition of a three bedroom trailer. Based on the engineer's design, a single bedroom dwelling could be added to the existing system. Regulations require that we permit the structure and not the intend use. If we permitted a three bedroom trailer as a one bedroom, there is no way to ensure this use would not change. One solution would be to modify the trailer into a one bedroom dwelling. If you have any questions, please do not hesitate to call this office. Sincerely, J Rdger Boyd Assistant Environmental Health Officer cc. ISDS file 1077 rA COMMUNITY DEVELOPMENT DEPARTMENT (303) 328-S730 EAGLE COUNTY, COLORADO February 1, 1993 Mr. Nathan Finkel P.O. Box 1581 Avon, CO 81620 Re: Building Permit Application 5596 Dear Mr. Finkel, 500 BROADWAY P.O. BOX 179 EAGLE. COLORADO S 1631 FAX (303) 325-7207 I am writing in regard to the above referenced building permit application. The application to construct an apartment within your equestrian facility has been reviewed by all Divisions of Community Development as well as the Engineering Division. In leu of the response from the Environmental Health Division (see letter dated 1/25/93) and the Engineering Divisions disapproval (see routing sheet dated 12/15/92), your application has been denied. Occupancy of this apartment within the equestrian facility shall remain agricultural in nature. The residence/apartment is disallowed as per U.B.C. 205 requirements. If you have any questions, please Sincerely, Gerald Best Building Official encl: UBC 205 1/25/93 letter Eng. Routing Sheet xc: Montag Merry ✓ - /SDS P.`ti 1077 don't hesitate to call. Fj;�)16 e E 0 nM _._' nnruuln rAnu llr%LADADTLICAIT_' TYPICAL SEPTIC TANK DETAIL — NOT TO SCALE SEPTIC TANK NOTES 1. SOLID PVC PIPE MEETING ASTM STANDARD D3034 SDR35, PROPERLY SUPPORTED TO PREVENT FAILURE BY SETTLING SHALL EXTEND FROM THE SEPTIC TANK FOR A DISTANCE OF AT LEASE 5 FEET FROM THE INLET AND OUTLET ENDS. 2. THE OPENING COVER OF A SEPTIC TANK MANHOLE. IN- SPECTION PORT OR ACCESS PORT SHALL BE NO DEEPER THAN Bw BELOW FINISH GRADE I 3. SEPTIC TANK SHALL BE DESIGNED TO WITHSTAND H-20 AXLE LOADS, OR BARRIERS SHALL BE PROVIDED TO EXCLUDE VEHICLE TRAFFIC FROM THE TANK SITE. 4. THE SEPTIC TANK SHALL BE DESIGNED TO WITHSTAND 5 FEET OF SATURATED OVERBURDEN RUBY RIDGE RANCH SEPTIC SYSTEM DESIGN A PARCEL OF LAND LOCATED IN TRACT 56, A PART OF TRACT; 57, AND LOTS 5, 6, 7, 8, AND 9 OF SECTION 11, TOWNSHIP 5 SOUTH, RANGE 83 WEST OF THE SIXTH PRINCIPAL MERIDIAN F EAGLE COUNTY, COLORADO 50' OFFSET EDGE OF CREEK INSPECTION PORT HOLE EDGE -OF CREEK A'Is 20OFFSET FROM BUILDING - APPROXIMATE LOCATION \ i ROOF \ PROFlLE HOLE OVERHANG 13\ \ J \ 1 \\ \ PROEST HOLLEOSATI \ \ /Z TLC I \ \ 1 \ C \ IINNLET DISTRIBUTION ELEV. 7456.64 EQUESTRIAN \ \ BUILDING *'PVC STUB OUT ELEV. 7462.24 INVERT our , 1 \ ELEV. 7459.45 \ SEPTIC TANK ` 1 \ 1000 GALLON \ INSPECTION PORT HOLE 1 1 1 INVERT IN STUB OUT 4•PVC ELEV. 7459.70 ` ELEV. \ 7462.13 \\ \ I 1 . I I BOTTOM OF BANK WELL 1 I/ TOP OF BANK WATER WELL BUILDING SLOPE AWAY FROM BUILDING EXISTING GROUND I TRENCH INFILTRATOR INFILTRATOR TRENCH DISTRIBUTION PIPE L-- 3� .I. 6' .I. 3' — TRENCH DETAIL N.T.S. NOTE: INSTALL INFILTRATOR TO MANUFACTURERS RECOMIENDATION. SIZE: STANDARD INFILTRATOR 3' ( 6 1/4' X 1' E i OFFSET 50' 3' MINIMUM �� ( �5 COVER DISTRT ION PIPE zs WATER WELL OFFSET 100' GRAPHIC SCALE A 0 10 m 40 so ( IN FEET 1 inch - 20 t 4 NOTE: IhnLTRATI SYSTEM IS LOCATED 100' FROM THE WATER WELL IhFILTRATI SYSTEM IS LOCATED 50' AWAY FROM THE WEST SIDE OF THE CREEK. IhFILTRATI SYSTEM IS LOCATED 20' AWAY FROM THE BUILDING. I o� ABSORPTION BED CALCULATIONS INFILTRATKWICALCULATIONS t AVERAGE 0 0 MPI1 S PEAK FACTOR�� 48��� 756 - 40% of 756-= 454 454/18.75 SF = 0 A= 0/5 X t 5� f S 25 X 6.02 150.50 A = 756 SF 756/3 = 252 FT of TRENCH } 3 X 84 = 252 FT=of TRENCH -DESIGNED K� F PRELIMINARY ul A N u' U 'h" L'OONS,' f A � f - W _uu I I lil RECEIVED AUG 0 1 991 EAGLE Count' M ^rY U'ITY DEVEIOPP ENT